IS 12615 : 2011

Indian Standard
ENERGY EFFICIENT INDUCTION MOTORS
THREE PHASE SQUIRREL CAGE
(Second Revision)
1 SCOPE 1.3To conform to this standard and eligible to be
considered as energy efficient, the motors shall meet
1.1This standard covers the requirements and the norms specified in Tables 1 to 3 when read in
performance of energy efficient, 3 phase squirrel cage conjunction with 4 related to site conditions as
induction motors in 2, 4, 6 poles for frame sizes from applicable. All performance values are subjected to
71 up to and including 315L having output ratings tolerances specified in IS/IEC 60034-1 : 2004 Rotating
as specified in IS 1231 : 1974 Dimensions of three- electrical machines Part 1: Rating and
phase foot-mounted induction motors for performance except that these tolerances are not
continuous duty (S1) operation with service factor applicable on speed and breakaway torque specified
1.0 or S3 (intermittent periodic duty) with a cyclic in Tables 1, 2 and 3.
duration factor of 80 percent or higher, at rated
voltage and frequency of 415 V, 50Hz. NOTE This standard does not apply to:
a) motors made exclusively for converter duty
NOTE The ratings and related frame sizes are given in application;
the tables given at the end with relevant performance
values. b) motors completely integrated into the machine
(for example, pumps, compressors, special
1.2The performance of motors designed for machines, etc) that cannot be tested separately
from the machine; and
operation on voltage other than rated voltage
c) motors rated for duty cycles S4 and above except
mentioned in 1.1 but up to 1 000 V, shall be in if an equivalent S1 duty is specified by the driven
accordance with the relevant performance values equipment manufacturer.
specified in Tables 1 to 3 except for the full load
current values. The full load current will vary in the 2 REFERENCES
inverse proportion to the voltage in comparison to The standards listed in Annex A are necessary
the values specified in Tables 1 to 3. adjuncts to this standard.
ANNEX A
(Clause 2.1)
LIST OF REFERRED INDIAN STANDARDS

IS No. Title
1231 : 1974 Dimensions of three phase foot mounted induction motors
1885 (Part 35) : 1993 Electro technical vocabulary: Part35 Rotating machines
2223: 1983 Dimensions of flange mounted ac induction machines
2254: 1985 Dimensions of vertical shaft motors for pumps
3043 : 1987 Code of practice for earthing
6362 :1995/IEC 34-6 : 1991 Designation of methods of cooling of rotating electric machines
7816 : 1975 Guide for testing insulation resistance of rotating machines
12065 : 1987 Permissible noise levels for rotating electrical machines
12075: 2008 Mechanical vibration of rotating electrical machines with shaft heights 56 mm
and higher Measurement, evaluation and limits of vibration severity
13508: 1992 Test procedure for measurement of loss tangent angle of coils and bars for
machine winding Guide
14222 : 1995/IEC 34-15 : 1992Impulse voltage withstand levels of rotating a.c. machines with form-wound
stator coils
15999 (Part 2/Sec 1) : 2011/ Rotating electrical machines: Part2 Methods of tests, Section 1 Standard
IEC 60034-2-1 : 2007 methods for determining losses and efficency from tests (excluding machines
for traction vehicles) (under print)
IS/IEC 60034 Rotating electrical machines:
(Part 1) : 2004 Rating and performance
(Part 5) : 2000 Degrees of protection provided by the integral design of rotating electrical
machines (IP Code) Classification
(Part 8) : 2002 Terminal markings and direction of rotation