Professional Documents
Culture Documents
Technology Training
SDH Overhead
Multiplex Section
Regenerator Section
Regenerator Regenerator
Path Multiplex Section Section Multiplex Path
Termination Section Termination Termination Section Termination
Termination Termination
270 x N columns
9 x N columns
RSOH
3 rows
Regenerator
Section
Overhead
9 rows
Administrative Payload
Unit (Pointer)
MSOH
5 rows
Multiplex
Section
Overhead
125 us
A1 A1 A1 A2 A2 A2 J0 Z3
B1 E1 F1 Z4
D1 D2 D3 Z5
H1 H1 H1 H2 H2 H2 H3 H3 H3 J1
B2 B2 B2 K1 K2 B3
D4 D5 D6 C2
D7 D8 D9 G1
D10 D11 D12 F2
S1 M1 E2 H4
D4 | | | D5 | | | D6 | | |
D7 | | | D8 | | | D9 | | |
S1 | | | M1 | | | E2 | | | X|X|X|X X|X|X|X
AUG-16
x4
GFP-T C4 VC-4 AU-4 AUG-1 AUG-4
x4
3
GFP-F C3 VC-3 TU-3 TUG-3 x
7
x
TUG-2
3
x
C12 VC-12 TU-12
RSOH:
Supported: A1 fixed 0xF6, A2 fixed 0x28, B1, J0 set to
0x01
Supported: D1-D3 as SDCC, E1, F1, J0 not monitored
Pointer
H1, H2 with pointer adjustments supported
MSOH:
Supported: B2, D4-D12 as LDCC, K1, K2[6-8],M1,S1
fixed to 0xFF
Not supported: E2
B1 (regeneration section):
Errored Seconds
Severely Errored Seconds
Out of Frame Seconds
Background Block Error Rate
B2 (multiplex section):
Errored Seconds
Severely Errored Seconds
Unavailable Seconds
Background Block Error Rate
B3 (VC-4 path):
Errored Seconds
Severely Errored Seconds
Unavailable Seconds
Background Block Error Rate
SNCP
for all network structures
Trail protection:
Multiplex section protection (MSP)
Line A
Client signal
Client
Line B
Unidirectional / bidirectional
Revertive /non-revertive
1+1
Unidirectional
Non-Revertive
Switching criteria:
LOS, LOF, MS-AIS, SD
IMPORTANT NOTICE
The content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content, material, and information in this
presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited.
The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representations of any kind, either express or
implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss or damages, including without limitation, direct, indirect, incidental,
consequential and special damages,
alleged to have been caused by or in connection with using and/or relying on the information contained in this presentation.
Copyright for the entire content of this presentation: ADVA Optical Networking.