You are on page 1of 6

Sensors and Transmitters

for the HVAC Professional

Greystone Energy Systems Inc., is one of North Americas largest


ISO registered manufacturers of HVAC/R sensors and transmitters
for Building Automation and Energy Management Systems.

We have conscientiously established a worldwide reputation as


an industry leader by maintaining leading-edge design
technology, prompt technical support, and a commitment to
on-time deliveries.

We take pride in our Quality Management System which is ISO


9001 certified, assuring our customers of consistent product
reliability.

Temperature Sensors
Temperature Transmitters
Humidity Transmitters
Gauge Pressure Transmitters
Differential Pressure Transmitters
Static Pressure Transmitters
Air Flow Transmitters
Current Switches & Sensors
Analog to Pneumatic (I/P) Transducers
Signal Conditioning Interfaces
Power Supplies
Air Quality Monitors
Carbon Dioxide Detectors
Carbon Monoxide Detectors

Peace of mind
through reliable sensors
GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM
TEMPERATURE SENSOR/TRANSMITTERS
TRC, TE200, TSPC, TXRC, TE500, TE511/2 SERIES
Platinum & Nickel RTD, or NTC thermistor sensors
Wall, duct, duct average, immersion, outside air, etc.
Optional features include set point adjust, push button
switch, fan speed switch and external/internal jacks
High accuracy temperature transmitters for any application
Transmitters with optional output signal types, power
supplies and temperature ranges
Optional LCD temperature indication
Custom logos available

RELATIVE HUMIDITY TRANSMITTERS


SPC, HRC, HTRC, RH*00, RH*10 SERIES
Wall, duct or outside models LCD options available
Accuracy 2% , 3% or 5% Temperature options available
Humidity span 0% to 100% Optional set point adjust,
Highly stable push button switch,
Fast response fan speed switch
Field selectable outputs AC/DC operation
4-20mA, 0-1 Vdc,
0-5 Vdc, 0-10 Vdc

GAUGE PRESSURE TRANSMITTERS: PGS SERIES


Ranges -14.7 through 10,000 PSIG (0 through 68,947 kPa)
DC input, current output
Compensated temperature range from -20C to 80C
Sensor operating temperature range from -40C to 127C
17-4PH Stainless Steel provides excellent corrosion resistance
(comparable to Grade 304 SS)

GAUGE / WET TO WET PRESSURE TRANSMITTERS:


WP SERIES
Excellent long-term stability Four switch selectable
Long life pressure ranges
High performance PSIG/PSID/kPa/Bar
Jumper selectable LCD Autozeroing
backlight for low power Jumper selectable output types:
consumption applications 4-20 mA, 0-5 and 0-10 Vdc
Bi-directional switch IP65 (NEMA 4) enclosure
Port swap switch

ROOM PRESSURE MONITOR: RPC SERIES


Ranges 1 W.C. to 0.125 W.C. (250 Pa to 30 Pa)
Field selectable outputs
Precision silicon sensor
24 Vac/dc power supply standard
Functional and attractive enclosure
LCD display, on-board buzzer & alarm output

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM


LOW PRESSURE TRANSMITTERS: LP3 SERIES
Ranges 1" W.C. to 20W.C. ( 250 Pa to 2000 Pa)
Jumper selectable 2 wire current or 3 wire voltage outputs
24 VAC/DC nominal power supply standard
6 jumper selectable pressure ranges per model, WC or Pa
Weather resistant ABS enclosure
Available options include LCD display & integrated static probe

ULTRA LOW PRESSURE TRANSMITTERS:


ULP SERIES
Ranges 0.125" W.C. to 1" W.C. (30 to 250 Pa)
3 jumper selectable current or voltage outputs
24 VAC/DC nominal power supply standard
8 jumper selectable pressure ranges per model, WC or Pa
Weather resistant ABS enclosure
Optional LCD display available
Optional relay output
Optional BACnet Communications

PRESSURE SWITCH AND AIR FLOW TRANSMITTER


Pressure Switch (GFS) Air Flow Transducer (ESF-35-2)
Housing contains Converts airspeed into a
diaphragm, calibration 4-20mA or a 0-10 VDC signal
knob and snap acting Linear output signal
SPDT switch Made with corrosion resistant
Enclosure cover guards material
against accidental contact Fully electronic registration
Optional pressure ranges of airflow speed
Setpoint Indication

CURRENT SWITCHES: CS/SC SERIES


2 solid core models (CS Series)
Split core models
Self-powered and no insertion loss
Mosfet or triac switching models
Fixed or adjustble trip point models
High current output models
Small compact size
Easy field adjustment with status LEDs on some models
Input / Output isolation via current transformer
Optional snap-on command relay

CURRENT SENSORS: CS/SC SERIES


2 solid core models (CS Series)
Split core models (SC Series)
Fixed or selectable range models available
No field adjustment necessary, factory calibrated
Outputs: 4-20 mA, 0-5 Vdc and 0-10 Vdc (Model specific)
True RMS measurement for sine waves or variable frequency
drives on some models

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM


ELECTRONIC TO PNEUMATIC TRANSDUCERS:
ETP-9500 SERIES
Direct connection to PCs for pneumatic control
Two-wire loop powered or three-wire voltage models
Easily accessible wiring terminal blocks
Snap-track or enclosed
High accuracy with low hysteresis
Driftless operation with high repeatability
AC/DC operation

SIGNAL CONDITIONING INTERFACES


Analog rescaling
Analog isolation
Analog to relay
Analog to resistance
Input signal and power supply protection
AC/DC operation
Easy field calibration
Quick panel mounting with supplied snap-track

CARBON DIOXIDE DETECTORS: CDD SERIES


Wall, duct or outside models
Setup/calibration fully menu driven
Monitoring ranges of 0-2000 or 0-20,000 ppm
Field adjustable range without re-calibration
NDIR single beam or dual beam with patented ACLP
self-calibration algorithm
Guaranteed 5 year calibration interval
Optional on board relay with field adjustable trip point
LCD for displaying PPM level and menu options (concealable)
Optional temperature and humidity outputs
BACnet or Modbus Communication models
Powered by either AC or DC source

CARBON MONOXIDE DETECTORS: CMD SERIES


Wall or duct models
Setup/calibration fully menu driven
Electrochemical sensing element
Field-selectable ranges of 0-100, 150, 300, 400 or 500 PPM
LCD for displaying PPM level and menu options
Built-in test switch and field adjustable alarm buzzer
Powered by either AC or DC source
3 field-selectable analog outputs linearized over full range
Field replaceable calibrated sensor module
Optional on-board relays with field adjustable trip point
BACnet or Modbus Communications

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM


AIR QUALITY MONITORS: AIR-300
Wall or Duct mount models
VOC (Volatile Organic Compounds) detection
Microprocessor based controller
Analog, stepped, and relay output options
10-bit resolution
Able to detect one cigarette in 15m3 (530 cu. ft.) room
Integral sensitivity adjustment
Visual indication of air quality (internal)

DUCT SMOKE DETECTORS: SL-2000


24 VAC/DC or 120/240 VAC operation
Simple change-out of photo or ion detector heads
Low flow air velocity rating from 100 to 4000 FPM
UL, CSFM amd MEA Listed
Two (2) sets of 10A form C alarm contacts
One (1) set of 10A form C trouble contacts
Easy and quick mounting to round or rectangular
ducts from 1 to 12 wide
Clear cover for convenient visual inspection

REGULATED DC POWER SUPPLIES


24 VAC input/DC outputs
Factory set at 24 VDC out
Adjustable voltage outputs
Full or half wave rectified
Fuse protected
Snap track mounted

WATER DETECTORS: WD100 SERIES


Stand alone model
Remote probe model
Conductivity cable model available in various lengths
Fail-safe circuitry
Reverse acting contacts
Reverse voltage protection

MISCELLANEOUS CONTROL DEVICES


Light sensor/transmitter - PSR Series
Loop powered indicators - LP1 Series
Damper end switch - DES-100 Series
General purpose relays - LY & MY & Series

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM


Greystones head office and factory is located in Moncton, New Brunswick, Canada. Over the
past 10 years, we have strategically opened offices throughout the world to better serve our
customers. Additionally, we have created partnerships in specific areas for distribution of
Greystone products. For more information on our products or to check for a distributor in your
area, please contact the closest office from the list below.

HO
Office
Distribution

V.01/14
Head Office and Factory Eastern US Sales Office
Greystone Energy Systems Inc. Greystone Energy Systems Inc.
150 English Drive, 356 Hickory Hollow Road,
Moncton, New Brunswick Somerset, Pennsylvania

Copyright Greystone Energy Systems Inc. All Rights Reserved


Canada E1E 4G7 USA 15501

(506) 853-3057 Fax : (506) 853-6014 (603) 458-1436 Fax : (603) 458-1689
North America: 1-800-561-5611 North America: 1-800-561-5611 Ext. 111

Asia Pacific Sales Office Western US Sales Office


Greystone Energy Systems Pte. Ltd. Greystone Energy Systems Inc.
111, North Bridge Road 6557 English Drive,
#27-01 Peninsula Plaza Avon, Indiana
Singapore 179098 USA 46123

Phone: +65-6507-4512 (317) 203-7138 Fax : (317) 203-3242


Fax: +65-6507-4488 North America: 1-800-561-5611 Ext 210

mail@greystoneenergy.com
www.greystoneenergy.com
PRINTED IN CANADA

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM