E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -01 Chip Conveyning
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 76.2
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
16 Type of drive (Direct/belt) Belt
17 If Belt driven specify belt Details Follow manufacture standard
18 No. Of belts in case of belt driven Follow manufacture standard
Cooling coil
19 Manufacturer Daikin
20 Material of tube and fins Copper/Aluminum
21 Method of bonding tube and fins Follow manufacture standard
22 ADP - deg. C -
23 Entering air temperature DB & WB 23.3/16.6
24 Leaving air temperature DB & WB 14.74/13.25
25 Entering water temperature - deg. C 7
26 Leaving water temperature - deg. C 12
Air filter
27 Manufacturer AAF
28 Type of pre filters G4
29 Media used Synthetic
30 Arrestance & efficiency 87-92%
31 Resistance when clean - mm -
32 Whether commissioning filter included-Yes/No No
33 Method of cleaning compressed Air
34 Face velocity across filter (MPS) 1.78 m/s
35 Pressure drop across filter (mm of water) 200 Pa ( final)
Motor
36 Make of motor Teco
37 Type of motor TEFC
38 Speed of motor 1465 RPM
39 Degree of motor protection Follow manufacture standard
40 Class of insulation IP55
41 Operating voltage 380V/3Ph/50Hz
1
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
44 Whether door switch with light included-Yes/No Yes for fan section
General (To be specified for all AHUS)
1 Model DDM2-1015
2 Overall Dimensions - W x D x H - mm 1950x3000x1530 mm
3 Overall weight - Kg 773.2 kg
4 Whether inbuilt sound attenuator for AHU included-Yes/No No
5 Depth of sound attenuator - mm N/A
Fan Section
6 No. of fan drums 1
7 Air flow - CMH 3970 l/s
8 Total Static pressure - mm wg 823.377 Pa
9 Operating speed - RPM 1506 RPM
10 Critical speed RPM -
11 Fan wheel diameter(mm) -
12 BKW -
13 Fan outlet velocity - MPS 9.754 m/s
14 Fan outlet area 645 x 645 mm
15 Static pressure at outlet ( in mm of water column) 400 Pa
Cooling coil
16 Capacity of cooling coil - TR 42.32 kW
17 Coil face area - sq.mt -
18 Total surface area - sq.mt 1.839 m2
19 No. of rows 3
a. Vertical -
b. Horizontal Y
20 Diameter of tube - mm 12.7 mm
21 Tube thickness 0.406 mm
22 No. of fins/cm 10 FPI ( Fin per inch)
23 Type of fins Corrugated
24 Fin thickness 0.115 mm
25 Test pressure 350psig ( 24 bar)
26 Velocity of water through tubes (MPS) 0.622 m/s
27 No of circuits 27
28 Pressure drop in coil (m of water) 39.591 kPa
29 Water flow - LPM 2.122 l/s
30 Water side Pressure drop - KSC 16.258 kPa
Air filter
31 Size and number of pre filters 24x24- 6pcs
32 Face area 2.23 m2
Motor
33 KW of motor 5.5 kW
34 Speed of motor 1455 RPM
35 Starting current of motor / Full Load current of Motor- Amps 10.6 A
2
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
3
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
4
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
5
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
6
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
19 Manufacturer Daikin
20 Material of tube and fins Copper/Aluminum
21 Method of bonding tube and fins Follow manufacture standard
22 ADP - deg. C -
23 Entering air temperature DB & WB 23.2/16.4 oC
24 Leaving air temperature DB & WB 15.19/13.25 oC
25 Entering water temperature - deg. C 7
26 Leaving water temperature - deg. C 12
Air filter
27 Manufacturer AAF
28 Type of pre filters G4
29 Media used Synthetic
30 Arrestance & efficiency 87-92%
31 Resistance when clean - mm -
32 Whether commissioning filter included-Yes/No No
33 Method of cleaning Compressed Air
34 Face velocity across filter (MPS) 2.28 m/s
35 Pressure drop across filter (mm of water) 200 Pa ( final)
Motor
36 Make of motor Teco
37 Type of motor TEFC
38 Speed of motor 1470 RPM
39 Degree of motor protection Follow manufacture standard
40 Class of insulation IP55
41 Operating voltage 380V/3Ph/50Hz
44 Whether door switch with light included-Yes/No Yes for fan section
General (To be specified for all AHUS)
1 Model DDM2-1827
2 Overall Dimensions - W x D x H - mm 3150x3600x2350mm
3 Overall weight - Kg 1883.8 kg
4 Whether inbuilt sound attenuator for AHU included-Yes/No No
5 Depth of sound attenuator - mm N/A
Fan Section
6 No. of fan drums 1
7 Air flow - CMH 11447 l/s
8 Total Static pressure - mm wg 794.098 Pa
9 Operating speed - RPM 986 RPM
10 Critical speed RPM -
11 Fan wheel diameter(mm) -
12 BKW -
13 Fan outlet velocity - MPS 11.311 m/s
14 Fan outlet area 1010x1010 mm
15 Static pressure at outlet ( in mm of water column) 350 Pa
Cooling coil
16 Capacity of cooling coil - TR 114.224 kW
17 Coil face area - sq.mt -
18 Total surface area - sq.mt 5.351 m2
19 No. of rows 3
7
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
a. Vertical -
b. Horizontal Y
20 Diameter of tube - mm 12.7 mm
21 Tube thickness 0.406 mm
22 No. of fins/cm 12 FPI
23 Type of fins Corrugated
24 Fin thickness 0.115 mm
25 Test pressure 350psig ( 24 bar)
26 Velocity of water through tubes (MPS) 1.048 m/s
27 No of circuits 23
28 Pressure drop in coil (m of water) 41.813 kPa
29 Water flow - LPM 5.727 l/s
30 Water side Pressure drop - KSC 21.613 kPa
Air filter
31 Size and number of pre filters 24x24- 12 pcs
32 Face area 5.02 m2
Motor
33 KW of motor 15 kW
34 Speed of motor 1470 RPM
35 Starting current of motor / Full Load current of Motor- Amps 27.6 A
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -04 Fiber Line
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 83.03
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
8
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
9
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
10
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
Cooling coil
19 Manufacturer Daikin
20 Material of tube and fins Copper/Aluminum
21 Method of bonding tube and fins Follow manufacture standard
22 ADP - deg. C -
23 Entering air temperature DB & WB 23/16.4 oC
24 Leaving air temperature DB & WB 14.93/13.4 oC
25 Entering water temperature - deg. C 7
26 Leaving water temperature - deg. C 12
Air filter
27 Manufacturer AAF
28 Type of pre filters G4
29 Media used Synthetic
30 Arrestance & efficiency 87-92%
31 Resistance when clean - mm -
32 Whether commissioning filter included-Yes/No No
33 Method of cleaning Compressed Air
34 Face velocity across filter (MPS) 1.907 m/s
35 Pressure drop across filter (mm of water) 200 Pa ( final)
Motor
36 Make of motor Teco
37 Type of motor TEFC
38 Speed of motor 1450 RPM
39 Degree of motor protection Follow manufacture standard
40 Class of insulation IP55
41 Operating voltage 380V/3Ph/50Hz
44 Whether door switch with light included-Yes/No Yes for fan section
General (To be specified for all AHUS)
1 Model DDM2-0715
2 Overall Dimensions - W x D x H - mm 1950X3000X1250mm
3 Overall weight - Kg 673.6 kg
4 Whether inbuilt sound attenuator for AHU included-Yes/No No
5 Depth of sound attenuator - mm N/A
Fan Section
6 No. of fan drums 1
7 Air flow - CMH 3185 l/s
8 Total Static pressure - mm wg 716.854 Pa
9 Operating speed - RPM 1621 RPM
10 Critical speed RPM -
11 Fan wheel diameter(mm) -
12 BKW -
13 Fan outlet velocity - MPS 9.873 m/s
14 Fan outlet area 575x575 mm
15 Static pressure at outlet ( in mm of water column) 300 Pa
Cooling coil
16 Capacity of cooling coil - TR 30.321 kW
17 Coil face area - sq.mt -
18 Total surface area - sq.mt 1.328 m2
11
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
19 No. of rows 3
a. Vertical -
b. Horizontal Y
20 Diameter of tube - mm 12.7 mm
21 Tube thickness 0.406 mm
22 No. of fins/cm 10 FPI
23 Type of fins Corrugated
24 Fin thickness 0.115 mm
25 Test pressure 350psig ( 24 bar)
26 Velocity of water through tubes (MPS) 0.64 m/s
27 No of circuits 20
28 Pressure drop in coil (m of water) 47.957 kPa
29 Water flow - LPM 1.52 l/s
30 Water side Pressure drop - KSC 10.657 kPa
Air filter
31 Size and number of pre filters 24x24- 3 pcs
32 Face area 1.67 m2
Motor
33 KW of motor 4 kW
34 Speed of motor 1450 RPM
35 Starting current of motor / Full Load current of Motor- Amps 7.84 A
12
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
13
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -07 Drying Machine
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 81.92 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
16 Type of drive (Direct/belt) Belt
14
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
15
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -08 Testing Lab
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 76.74 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
16
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
17
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -09 Drying Machine 3
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 79.58 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
18
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
19
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
Cooling coil
16 Capacity of cooling coil - TR 102.442 kW
17 Coil face area - sq.mt -
18 Total surface area - sq.mt 3.827 m2
19 No. of rows 3
a. Vertical -
b. Horizontal Y
20 Diameter of tube - mm 12.7 mm
21 Tube thickness 0.406 mm
22 No. of fins/cm 10 FPI
23 Type of fins Corrugated
24 Fin thickness 0.115 mm
25 Test pressure 350psig ( 24 bar)
26 Velocity of water through tubes (MPS) 1.442 m/s
27 No of circuits 15
28 Pressure drop in coil (m of water) 59.913 kPa
29 Water flow - LPM 5.136 l/s
30 Water side Pressure drop - KSC 40.616 kPa
Air filter
31 Size and number of pre filters 24x24- 9 pcs
32 Face area 3.9 m2
Motor
33 KW of motor 15 kW
34 Speed of motor 1470 RPM
35 Starting current of motor / Full Load current of Motor- Amps 27.6 A
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -10 Drying Machine CR
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 79.28 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
20
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
16 Type of drive (Direct/belt) Belt
17 If Belt driven specify belt Details Follow manufacture standard
18 No. Of belts in case of belt driven Follow manufacture standard
Cooling coil
19 Manufacturer Daikin
20 Material of tube and fins Copper/Aluminum
21 Method of bonding tube and fins Follow manufacture standard
22 ADP - deg. C -
23 Entering air temperature DB & WB 23.1/14.9 oC
24 Leaving air temperature DB & WB 11.57/10.25 oC
25 Entering water temperature - deg. C 7
26 Leaving water temperature - deg. C 12
Air filter
27 Manufacturer AAF
28 Type of pre filters G4
29 Media used Synthetic
30 Arrestance & efficiency 87-92%
31 Resistance when clean - mm -
32 Whether commissioning filter included-Yes/No No
33 Method of cleaning Compressed Air
34 Face velocity across filter (MPS) 2.298 m/s
35 Pressure drop across filter (mm of water) 200 Pa ( final)
Motor
36 Make of motor Teco
37 Type of motor TEFC
38 Speed of motor 1470 RPM
39 Degree of motor protection Follow manufacture standard
40 Class of insulation IP55
41 Operating voltage 380V/3Ph/50Hz
44 Whether door switch with light included-Yes/No Yes for fan section
General (To be specified for all AHUS)
1 Model DDM2-1819
2 Overall Dimensions - W x D x H - mm 2350x3400x2350mm
3 Overall weight - Kg 1612.9 kg
4 Whether inbuilt sound attenuator for AHU included-Yes/No No
5 Depth of sound attenuator - mm N/A
Fan Section
6 No. of fan drums 1
7 Air flow - CMH 8963 l/s
8 Total Static pressure - mm wg 835.308 Pa
9 Operating speed - RPM 1119 RPM
10 Critical speed RPM -
11 Fan wheel diameter(mm) -
12 BKW -
13 Fan outlet velocity - MPS 11.120 m/s
14 Fan outlet area 910x910mm
21
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
22
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
23
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -12 Recovery Boiler
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 80.86 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
24
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
25
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
26
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
27
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
12 BKW -
13 Fan outlet velocity - MPS 8.933 m/s
14 Fan outlet area 1200 x1200 mm
15 Static pressure at outlet ( in mm of water column) 350 Pa
Cooling coil
16 Capacity of cooling coil - TR 131.981 kW
17 Coil face area - sq.mt -
18 Total surface area - sq.mt 5.351 m2
19 No. of rows 3
a. Vertical -
b. Horizontal Y
20 Diameter of tube - mm 12.7 mm
21 Tube thickness 0.406 mm
22 No. of fins/cm 10 FPI
23 Type of fins Corrugated
24 Fin thickness 0.115 mm
25 Test pressure 350psig ( 24 bar)
26 Velocity of water through tubes (MPS) 1.211 m/s
27 No of circuits 23
28 Pressure drop in coil (m of water) 48.178 kPa
29 Water flow - LPM 6.617 l/s
30 Water side Pressure drop - KSC 27.533 kPa
Air filter
31 Size and number of pre filters 24x24- 12 pcs
32 Face area 5.02 m2
Motor
33 KW of motor 18.5 kW
34 Speed of motor 1475 RPM
35 Starting current of motor / Full Load current of Motor- Amps 34.2 A
28
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
29
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -15 Turbine Boiler
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 77.56 dBA
8 Noise level at 1m from the filter side (dBA) N/A
9 Vibration level N/A
30
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
Fan Section
10 Make of blower Kruger
11 Type of fan (forward/backward) Backward
12 Whether statically and dynamically balanced? - Yes/No Yes
13 Type of bearings Follow Standard L50
14 Material and thickness of Fan impeller and blades The blade is made of heavy
15 Material and thickness of housing Follow manufacture standard
16 Type of drive (Direct/belt) Belt
17 If Belt driven specify belt Details Follow manufacture standard
18 No. Of belts in case of belt driven Follow manufacture standard
Cooling coil
19 Manufacturer Daikin
20 Material of tube and fins Copper/Aluminum
21 Method of bonding tube and fins Follow manufacture standard
22 ADP - deg. C -
23 Entering air temperature DB & WB 23.2/16.4 oC
24 Leaving air temperature DB & WB 14.32/13.08oC
25 Entering water temperature - deg. C 7
26 Leaving water temperature - deg. C 12
Air filter
27 Manufacturer AAF
28 Type of pre filters G4
29 Media used Synthetic
30 Arrestance & efficiency 87-92%
31 Resistance when clean - mm -
32 Whether commissioning filter included-Yes/No No
33 Method of cleaning Compressed Air
34 Face velocity across filter (MPS) 2.292 m/s
35 Pressure drop across filter (mm of water) 200 Pa ( final)
Motor
36 Make of motor Teco
37 Type of motor TEFC
38 Speed of motor 1470 RPM
39 Degree of motor protection Follow manufacture standard
40 Class of insulation IP55
41 Operating voltage 380V/3Ph/50Hz
44 Whether door switch with light included-Yes/No Yes for fan section
General (To be specified for all AHUS)
1 Model DDM2-2027
2 Overall Dimensions - W x D x H - mm 3150x3800x2550 mm
3 Overall weight - Kg 2230.9 kg
4 Whether inbuilt sound attenuator for AHU included-Yes/No No
5 Depth of sound attenuator - mm N/A
Fan Section
6 No. of fan drums 1
7 Air flow - CMH 13200 l/s
8 Total Static pressure - mm wg 768.946 Pa
9 Operating speed - RPM 703 RPM
31
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -16 Power Boiler
data to be furnished for all AHUS)
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
7 Noise level at 1m from unit(dBA) 74.74 dBA
8 Noise level at 1m from the filter side (dBA) N/A
32
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
33
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
34
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
35
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -18 DM Plant Electric
data to be furnished for all AHUS) Room
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
5 Density of insulation kg/cu.mtr 40 kg/m3
36
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
37
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
E FLOOR MOUNTED AIR HANDLING UNITS (Individual AHU -19&20 Tech Office
data to be furnished for all AHUS) R&D
1 Make / Manufacturer Daikin
2 Type of Unit Horizontal
3 Thickness of casing in mm:
a) Inner casing (Material & Thickness) 0.5 mm
b) Outer casing (Material & Thickness) 0.5 mm
4 Material of insulation PU
38
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
39
Vietracimex_VNT 19 Bid Document C7-042
VCX 400 Project for HVAC System
40