You are on page 1of 80

Type Series Booklet

1481.5/4--10 SNW
Applications
Irrigation and drainage pumping stations, stormwater pumping stations, raw Tubular casing pumps
and clean water pumps in water works, cooling water pumps in power stations
and industry, industrial water supply and flood control. Dock-- and sluice
pumps.

Operating data
Capacities Q up to 2,4 m3/s
Total heads H up to 50 m
Pump sizes DN 400 up to 700
Temperature of liquid handled max. 60 oC

Design
Single stage vertical tubular casing pump with semi axial impeller, submerged
hydraulic assembly,
discharge nozzle above or below floor, welded riser pipes, non-withdrawable
rotating assembly.

Bearings and lubrication


Shafts supported in medium-lubricated, highly wear-resistant ResidurR bea-
rings, grease-lubricated anti--friction bearing in the drive stand to compensate
rotor weight and axial thrust.

Shaft sealing
Packed gland at discharge nozzle above floor, ResidurR plain bearing working
as throttle bush at discharge nozzle below floor.

Program classification / materials


Standard Custom made
program program
Material combinations
01 02 03 04 05
Inlet Nozzle GG--20 (GJL 200) Ni Resist 1.4517 /
Diffuser GG--20 (GJL 200) Ni Resist 1.4462
Discharge elbow GG--20 (GJL 200) Ni Resist
Riser pipe RSt 37-2 (S235JRG2) 316L 1.4462
Motor stool RSt 37-2 (S235JRG2)
Shafts C 45
SH+S 1.4021.05 1.4462
/ C45N
Impeller, open G--CuSn10 1.4408 1.4409 1.4517
Impeller , closed 1.4408 1.4409 1.4517

Designation
SNW M 500 -- 505 EBn 01

Series
Semi axial impeller
DN discharge nozzle
Impeller diameter (mm)
Installation Type
Material combination

SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Table of Contents

Contents Page Contents Page

Acceptance Testing Inspection and Testing 10 Mass Moment of Inertia Technical Data 23 to 74
Accessories 10 Materials 11
Applications 1 Min. Flow Qmin Performance Curves 21 to 73
Min. Submergence Depth Selection Guide 4
Bearing Arrangements 19 and 20
Bearings Shaft Guide Bearings 10 Nozzle Forces & Moments Technical Data 12
Bearings Thrust Bearing 10 NPSH Performance Curves 10, 21 to 73
Bearing sizes Technical Data 23 to 74 NPSH Selection Guide 4 to 9
Bottom Clearance Selection Guide 4 NPSHreq Performance Curves 10, 21 to 73

Capacity Performance Curves 21 to 73 Operating Data 1


Casing Design 1
Clear Passage 10 Painting Coating 11
Coating 11 Parts Lists 76 to 78
Connections Dimension Tables 14 to 18 Plain Bearings Shaft Guide Bearings 10
Coupling Drive 10 Power Reserve Selection Guide 8
Coupling Guard Drive 10 Pressure Limits Operating Limits 10
Product Temperatures Operating Limits 10
Design 1
Dimensions Dimension Tables 14 to 18 RESIDUR Materials 11
Direction of Rotation Drive 10
Drive 10 Sectional Drawings 76 to 78
Dry--running Shaft Guide Bearings 10 Selection Charts 3
Selection Guide 4 to 9
Efficiency Performance Curves 21 to 73 Shaft Guide Bearings 10
ESK Losses Selection Guide 7 Shafts 10
ESK Losses Performance Curves 21 to 73 Shaft Sealing 10
Shaft Protecting Sleeves 10
Flanges Dimension Tables 14 to 18 Shaft Couplings Shafts 10
Flood--proof Foundations 10 Spare Parts Recommended List of Spares 74
Foundation Blocks Foundations 10 Speeds Performance Curves 21 to 73
Foundation Ring Foundations 10 Starting Torque Selection Guide 4 to 9
Foundations 10 Start--up Mode Drive 10
Strainer Clear Passage 10
Gland Leakage Shaft Sealing 10 Strainer Size List of Liquids Handled 3
Gland Packing Shaft Sealing 10 Submergence Depth (ET) Dimensions 23 to 74
Grease Fill Thrust Bearing 10
Guarantees 10 Temperatures Operating Limits 10
Testing Inspection and Testing 10
Heads Performance Curves 21 to 73 Test Pressure Operating Limits 10

Impeller Data Technical Data 12 Wet--well installation Mounting Arrangements 10


Inlet Chamber Selection Guide 4 to 9

List of Liquids Handled 3


Lubrication Shaft Guide Bearings 10
Lubrication Thrust Bearing 10

2 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

List of Liquids Handled


Selection of material combinations depending on liquid handled
Liquids handled 1) Indications / Recommendations
Clean or potable water No pre--cleaning required
Dirty water
River water
Storm water Pre--cleaning
Pre cleaning by screen, overflow or baffle
Raw water 4)
Combined water and sewage
Distance between screen bars (mm) Overflow and baffle
Sewage with low dilution Q 2 m3/s 15 mm no
Sewage with low dilution Q 2 m3/s 20 mm no
Pump size Coarse screen Fine screen 2)
400 365
400--365
400 405
400--405
400--420
400 420 30
400--430
400 430
Sewage with dilution of min. 8--times
8 times 400--450 no
500--505
500 505 15
500 515
500--515
500--620
500 620
40
600--535
600 535
600 550
600--550
600--575
600--600
600--650
Storm water, river water with fibrous sludge 600--700
600 700 yes
600--720
600 720 60 20
700--655
700 715
700--715
700 755
700--755
Activated sludge max 3 % dry solid content
Industrial effluents contaminated with:--
-- paint suspension Material combination 01
-- varnish suspension
-- abrasive matters Material combination 02 3) -- 0.2 g/l max. solid content
Industrial effluent, slightly acidic (pH--value 6) Material combination 02 3) -- plus special coating
1) Liquids not mentioned here require in most cases upgraded material. Please consult.
2) to be applied in case of increased contamination of the liquid handled
3) Standard variant (page 11) to be ordered separately
4) by raw water please send a water analysis to KSB

Selection chart 50 Hz Selection chart 60 Hz

600--700 600--720
n= 980 n= 980
600--700 600--720
n=880 n=880

SNW 3
Rev.4, 15.05.2002
Type Series Booklet SNW

Selection Guide
The data in the boxes is essential for pump sizing.
A computerized quote can be supplied at short notice in response to the telefax enquiry.

Determination of Size and Capacity

Q = m3/h m3/s nominal capacity

Hgeo = m m static head


Hv = m head loss
H Hp =Hgeo + Hv nominal head at discharge nozzle at the outlet elbow

Hp = m m

ESK m inlet (E), column pipe (S), and discharge elbow (K) losses
initially estimated see characteristic curves
HSt = Hp + ESK m m stage head

SNW size as per selection chart and characteristic curve

Speed nKL = 1/min speed nKL from curve

Minimum Submergence Depth


z = m minimum submergence depth to pump inlet nozzle to
prevent air entering vortices at maximum capacity

For an unbenched inlet chamber with inlet cone, the graph applies
NOTE: For reduced submergence , KSB can propose covered
inlet chamber on demand.

z
t12 z + t11

t11

lmin b

zs = m difference in level between inlet cross section of the pump and the impeller centre line
reference level -- see table below
z -- zs = m
t11 = m bottom clearance -- see table below
Dimensions in mm
Discharge Nozzle DN Inlet Chamber
zs t11
DN2 b e
400 200 260 1000 500
500 250 320 1250 620
600 280 380 1500 750
700 330 440 1800 900
4 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

ze = m minimum submergence depth for cavitation--free operation at Qmin and Qmax

pe + pb pD v 2
e
z e NPSHreq + Hvs g
2g

where
NPSHreq [m] from curve
v2e
= 0 ve means flow velocity in the plant inlet cross--section suction water level
2g
Hvs 0 head loss in suction pipe or in inlet chamber
pe = 0 pressure above atmospheric in the inlet cross section i.e. on the inlet side
liquid level

ze NPSHreq -- 10 m, applies if, installation is at sea level therefore pb = 101300 N/m2

ze -- 10 m liquid level is open on the suction side

ze m the product is water with temperature of approximately 25 oC,


corresponding to = 997 kg/m3 and pD = 3170 N/m2

ze z -- zs

Air pressure pb ( absolute pressure) as a function of elevation


Height above sea level pb
m N/m2
0 101300
500 95500
1000 89900
2000 79500

Vaporization pressure pD (actual pressure at which water


evaporates) and density of water as a function of temperature
Water pD Density
temperature Sweet water Seawater
oC N/m2 kg/m3 kg/m3
15 1700 999 1030 to 1040
20 2340 998 1030 to 1040
25 3170 997 1030 to 1040
30 4250 995 1030 to 1040
35 5600 994 1030 to 1040
40 7500 992 1030 to 1040
50 12300 990 1030 to 1040
60 20000 983 1030 to 1040

I m 1) inlet chamber bottom level IV

III
II m 1) level of pump inlet nozzle ze

III m 1) minimum water level to II zs


prevent air entrainment
I t11

IV m 1) minimum water level for


cavitation--free operation

1) either the minimum suction water level III / IV or the level of inlet chamber bottom / pump inlet must be given
SNW 5
Rev.4, 15.05.2002
Type Series Booklet SNW

Select material combination according to product as per Materials Section page 11

Material combination j 01 -- fresh water


V
j 01 -- potable water
j 02
h3
and / or product
VII
h4

Installation / Submergence Depth / Bearing Arrangement


VI
Pump ground level level V = m

Maximum suction water level level VII = m


ET

a. Mounting arrangement j CD h3 min = m 2)

t5
Level V pump ground level m -- h3 min = m
= m ! max. suction water level level VII = m
Level V pump ground level = m
Level VI discharge nozzle centreline = m

II
h4 available m
h4 available m ! h4 min3) m Mounting arrangement CD

h4 available m ! h4 max3) m
Level VI dis. nozzle centreline m
Level II pump inlet nozzle m 4)

t5 available m t5 min = m 2)
1)selected construction with t5max m t5av = m

b. Mounting j EBd / EKd pump ground level V = m


Arrangement j EBn / EKn V

max. suction water level VII = m


Level V Pump ground level = m
Level II Pump inlet nozzle = m
VII

Submergence depth ET available m ETmin = m 2) ET

1)selected construction with ETmax m ETav = m

1) Select the optimum bearing arrangement as regards ESK losses (no. of bearings) II
and price (no. of bearing and shaft diameter) using tables on pages 23 to 74
2) See dimension tables on pages 14, 15, 16 17 and 18 Mounting arrangement EBn
3) See pages 23 to 74
4) See page 5

6 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Actual ESK losses / stage head


ESK losses = m as per curve pages 21 to 73
HSt = Hp + ESK = m + m
HSt = m

Note the following terms :--


Stage head HSt = the head measured directly downstream of the casing
Stage efficiency St = the efficiency shown in the curves
Pump head Hp = stage head minus ESK losses
pump head
Pump efficiency p = stage efficiency x
stage head

The heads Hst and efficiencies St in the curves refer to a measuring point directly downstream of the pump casing.
When selecting a pump bear in mind that these heads will be reduced by the losses in the inlet, riser pipe and dischar-
ge elbow of the pump (referred to as ESK losses).

Selection with effective motor speed


Speed from curve, nKL = 1/min
Effective motor speed, nm = 1/min if unknown, refer to pages 21 to 73
n KL
QKL = = m3/s
nm . Q
n
HSt KL = ( KL)2 . H St = m
nm

Impeller diameter range


D max / mm, D2A1) mm / D2I1) mm refer to curves pages 21 to 73

Stage efficiency / Pump efficiency


St = % stage efficiency, as per curve, pages 21 to 73
Hp
St KL = . st = %
H St

1) to be selected from the curves based on the Q KL and H St KL


SNW 7
Rev.4, 15.05.2002
Type Series Booklet SNW

Pump output / Motor output

Q[m3s] . H St[m] . [kgm 3] . 9.81[ms2]


PB = [kW]
St[].1000[WkW]

PB = 9.81 [kW]
1000

PB = kW

Q x . H Stx . . g
Px = Stx maximum power input in operating range

Px = 9.81 [kW]
1000

Px= kW

PM 1.0 Px kW when operating range is not known

PM 1.1 Px kW if it can be ensured that the pump can only be operated at rat--
ings below Px, determine pmax and select a motor referred
to this output allowing a 10% safety margin.

PM selected kW under special conditions e.g. the priming of siphon pipes at


part--load, a higher motor rating may be required.

P
Px Bx
B
PB

Qmin
Px max. power input in operating range
Hx
PB power input at duty point
Hx head at max. pump input HB B
HB head at duty point
Qx flow rate at max. pump input
QB flow rate at duty point
Bx duty point at max. pump input
B duty point
0 Q
Qx
QB

8 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Motor data for a computerized quote and for order processing

a. Motor type/size not known j enclosure


Motor size is selected

b. Motor type/size known j


1) Shaft length l mm
2) Shaft diameter d mm
3) Flange connection diameter a1 mm
4) Flange thickness c1 mm
5) Centring diameter b1 mm
6) Spigot depth f1 mm
7) Pitch circle diameter e1 mm
8) No. of bolt holes
9) Bolt hole diameter s1 mm
10) Motor height y mm
11) Radial extension (terminal box) XB mm
12) Casing diameter g mm
13) Weight m kg

Note:--
Dimensions for Sr. 1 to 3 at project stage
Dimensions for Sr. 4 to 13 at order stage
Further customer information

j Guaranteed performance data to ISO 2548, class C, standard

j Acceptance testing to ISO 3555, class B

Anticipated operating hours h/a

Starting torques
Refer to booklet 0110.001/2 G2 Starting Torques

Assuming a ratio of:--

static delivery head H Stat


= 0,8 1)
nominal head HN

and a short discharge line with a non--return valve, the starting torque
will be represented by a broken line in Fig. 2
P p [k W]
TPN = 9550 [Nm]
n M [1 min]
TPN = 9550 [Nm]

1) other boundary conditions on request

SNW 9
Rev.4, 15.05.2002
Type Series Booklet SNW

Operating Limits
Test Pressure of the discharge elbow : Pe = 1.2 x closed valve head, max. 10 bar
Closed valve head:--
Pressure corresponding to the shut--off head of the pump plus the suction pressure or the total pressure at the pump discharge
nozzle during operation at zero flow rate (Q=0)
Product temperatures : t = 0 to 60 oC
Ambient temperatures : t = --10 to 50 oC
For speeds refer to selection chart.
Shafts
Pump shaft, intermediate and drive shafts are connected by sealed sleeve couplings.
Shaft Sealing
On pumps in CD mounting arrangement, effected by the upper most shaft guide bearing as a result of throttling action in the bearing.
Arrangement EB and/or EK has a packed gland.
On CD pumps the sealing liquid is drained off via a small pipe located near the discharge elbow. On EB and/or EK pumps, which
are non flood--proof, the leakage liquid is drained off via a pipe through a bore hole in the discharge elbow into the inlet chamber.
On the flood--proof arrangement, a leakage water drain is to be provided by the customer.
Shaft Guide Bearings
Product--lubricated plain bearings. The bearing bushes are flexibly located in a renewable bearing body, by a layer of rubber.
The pumps are started up dry without any pre--lubrication. Permissable dry running period 15 s.
Shaft Protecting Sleeves
The sleeve situated in the area of packed gland can be easily renewed without removing the shaft. The sleeve at the bearing is
made of wear--resistant silicon carbide and is also renewable.
Thrust Bearing
Grease--lubricated antifriction bearings. For bearing sizes see pages 23 to 74.
Lubricant type : K2k to DIN 51 502.
Drive
Drive via IEC standard motors with lateral cooling--air outlet. The direction of rotation of the pump is clockwise viewed from the
driver. A FLENDER N--EUPEX drive coupling is used with the hub of the pump--side half coupling specially adapted to the particular
thrust bearing. The design of the drive stool ensures that there is no danger of accidental contact with the drive coupling.
All the usual starting modes are permissible, however, bear in mind that star/delta starting is not always feasible depending upon
the system arrangement.
Mounting Arrangements
Vertical wet--well installation
--Mounting arrangement CD : discharge pipe below ground level, drive motor above ground level
--Mounting arrangement EB and/or EK : discharge pipe and motor above ground level
Foundations
Mounting arrangement CD : Drive motor mounted on cast iron foundation blocks, concreted into position.
Mounting arrangement EB and/or EK : The riser pipe is attached to a flat steel foundation ring with sealing action, or to foundation
blocks, both of which are concreted into place. The foundation ring is held in place by anchor bolts. On the flood--proof (pressure--
proof) version a seal ring is fitted between the mounting flange and the foundation ring.
Clear Passage
The pump must be protected against the entry of any large solid particles in the product by the installation of suitable dirt and shingle
traps i.e. overflow sims, scum boards, rakes, etc. upstream of the pump (see page 3). Relevant experience and the clear passage
given for various pump sizes (see table Technical Data -- page 12) should be taken into consideration at the design stage.
Performance Curves
The NPSHreq curves relate to continuous operation with impeller materials as specified in the documentation.
The heads and performance data are for a product with density = 1.0 kg/dm3 and a kinematic viscosity of up to 20 mm2/s max.
Inspection and Testing
The performance data are guaranteed without acceptance test as per ISO 2548, class C.
Inspection testing and certification to ISO 3555, class B, 5 measuring points, is available at an extra charge.

Guarantees
KSB assumes guarantees within the frame work of its relevant conditions of supply.

Scope of Supply Accessories


--pump --IEC electric motor
--drive coupling --pressure gauge arrangement
--inlet cone --special tools
--foundation blocks

10 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Materials
Standard program Custom made program4)
Material combination 01 02 03 04 05
Part--No. Part designation Materials
138 Inlet Nozzle GG--20 (GJL--200) Ni Resist 1.45172) /1.44623)
144 Discharge elbow GG--20 (GJL--200) Ni Resist / 316L3) 1.45172) /1.44623)
171 Diffuser GG--20 (GJL--200) Ni Resist 1.45172)
176 Inlet cone RSt 37--2 (S235JRG2)1)3) / GG--20 (GJL--200) 316L5)3) 1.45172)
211 Pump shaft C 45 SH+S /
212 Intermediate shaft C45 N 1.4021.05 1.4462
213 Top shaft
Impeller, open G--CuSn10 1.4408 1.4409 1.45172)
230
Impeller, closed 1.4408 1.4409 1.45172)
341 Motor stool RSt 37--2 (S235JRG2)
452 Gland GG--20 (GJL--200) 1.4409 1.45172)
461 Gland packing asbestos free
501 Multiple ring C 45 N 1.4021.05 1.4462
502 Casing wear ring, open impeller5) 316 316L NA
GC--
502.1 Casing wear ring, closed impeller
CuSn7ZnPb 316 316L 1.4462
503 Impeller wear ring, closed impeller 316 316L 1.4462
Shaft protec. sleeve, bearing Residur
524
Shaft protec. sleeve, stuffing box 1.4138 1.4462
711 Riser pipe RSt 37--2 (S235JRG2)3) 316L3) 1.44623)
86--2 Coupling sleeve, cylindrical C 45 N 1.4021.05 1.4462
891 Foundation ring GG--20 (GJL--200)
898 Foundation bloc GG--20 (GJL--200)
Misc. Bolts and nuts 8.8 A4--70 1.4462

1) Bolted to the pump


2) Cast
3) Welded
4) On request
5) Equivalent to DIN: 1.4571

SNW 11
Rev.4, 15.05.2002
Type Series Booklet SNW

Coating

A ) Standard coating :

surfaces in contact with medium surfaces not in contact with medium


Pretreatment Blasting SA 2 1/2 , DIN 55928 T4
Primer 2--component Hi--build epoxy Zinc Phosphate Primer
Top coat 2--component Polyamide cured epoxy
1--component--acrylat--alkyd based coat, thickness 0.06 mm,
coaltar, ICI CTE--200, thickness 0.300,
RAL 5002 ultramarinblau (blue)
Black RAL 9005

_C) applications) :
B ) Special coating (approved for Potable Water and Cold Sea Water (<24_

surfaces in contact with medium surfaces not in contact with medium


Pretreatment Blasting SA 2 1/2 , DIN 55928 T4
Primer 2--component modified epoxy amine primer, Carboline 893 1)
Top coat 2--component epoxy Carboline 891 2), 1--component--acrylat--alkyd based coat, thickness 0.06 mm,
thickness 0.150 mm, RAL 5002 ultramarinblau (blue)
black RAL 9005
1) Primer applied only if specially requested by the Customer, the Carboline 891 is applied directly on the surface as standard practice
2) NSF, National Public Health (Norway), Drinking Water Certificate

C ) Special coating as per Customers Specification :


against extra charge dependent on individual projects.

12 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

TECHNICAL DATA
The given forces and moments are mean values for simultaneous loading in the three planes. If the forces and mo-
ments in one particular direction are larger than given in the table, refer to us.
The values in the tables are not valid for the reaction forces of non--tensioned expansion joints.
On mounting arrangement CD the discharge pipe must be located in the axial direction. Maximum distance of the
fixed point from the discharge nozzle : 4 m. An elbow support is also necessary if the discharge pipe has a flexible
extension piece. Maximum length of support : 4 m.

Dimensions in mm, Forces in N, Moments in Nm


Pump Technical data 1) Nozzle forces and moments
Casing Impeller Clear Nozzle Nozzle Nozzle
Impeller Impeller Impeller Force Force Force
size inlet dia
wear ring clea- passages
open closed
moment moment moment
dia rance 10% FX FY FZ MX MY MZ
400--365 290 -- 0,45 55 X --
400--405 314 -- 0,55 52 X --
400--420 286 -- 0,45 52 X -- 6500 6500 6500 1450 1450 1450
400--430 325 330 0,60 52 -- X
400--450 340 380 0,60 43 -- X
500--505 380 -- 0,55 57 X --
500--515 392 -- 0,55 84 X -- 8700 8700 8700 1800 1800 1800
500--620 382 425 0,60 65 -- X
600--535 425 -- 0,60 81 X --
600--550 420 -- 0,60 62 X --
600--575 460 -- 0,60 76 X --
600--600 455 -- 0,60 76 X -- 10700 10700 10700 2300 2300 2300
600--650 452 500 0,60 66 -- X
600--700 440 500 0,60 66 -- X
600--720 450 500 0,60 68 -- X
700--655 547 -- 0,75 114 X --
700--715 532 -- 0,75 81 X -- 14000 14000 14000 2800 2800 2800
700--755 588 -- 0,75 100 X --
1) For further data see pages 22 up to 73

SNW 13
Rev.4, 15.05.2002
Type Series Booklet SNW

DIMENSION TABLES
CD Mounting Arrangement
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request. d2

Connections 250 h3
200
1 M Pressure Guage G
8 A Leakage fluid outlet G 300
h4
Permitted Dimensional Tolerances
Centreline heights DIN 747. a
Dimensions with no tolerance DIN 7168 m.
Cast iron components DIN 1686 GTB 18
1M

Discharge Flange h2 DN2

Connection dimensions to DIN 2501, PN 10 h1


Flange thickness* to DIN EN 1092--2, PN 6 8A

* for operating pressure 6 bar DIN EN 1092--2, PN 10

Dimensions in mm, non--binding t4


Pump
u p Pump dimensions
size DN2 t5 min a d1 h1 h2 h3 min t1 ET
For ETmax and h4 see
400--365 1350 550 700
table t3
400--405 1450 550 800
400--420 400 1475 400 550 400 750 615 825
Technical data t5
400--430 1390 550 740 and dimensions
400--450 1625 600 975
t3
500--505 1630 645 880
500--515 500 1850 500 645 500 870 620 1100
500--620 1780 645 1030
600--535 1860 700 1010 t2
600--550 1895 700 1045
600--575 2065 775 1215
600--600 600 1930 600 775 600 990 620 1080
600--650 2050 775 1200
600--700 1950 750 1100 t1
600--720 2060 750 1210
700--655 2500 900 1550
700--715 700 2180 700 870 700 1125 690 1230
700--755 2410 980 1460 d1

m
Pump
u p Feet dimensions Foundation dimensions 50 50
size m n o1 o2 p1 p2 25

400--365 800 950 750 500 650 750


400--405 800 950 750 500 650 750
400--420 800 1050 750 500 750 850 n
400--430 800 950 750 500 650 750
400--450 940 1120 900 640 820 920 Plan view
25
500--505 940 1120 900 640 820 920
500--515 940 1120 900 640 820 920
4 holes 27
500--620 1140 1200 1100 840 900 1000
600--535
600--550
600--575 o1
600--600 1140 1200 1100 840 900 1000
600--650 p1 p2
600--700 1400 1100 1200
600--720 1340 1500 1300 1040 1200 1300
Foundation
700--655 holes
700--715 1340 1400 1300 1040 1100 1200 200 200
o2
700--755

14 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

DIMENSION TABLES
EB Mounting Arrangement (EBn) -- Non floodable version
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request.
d2

Connections h3 a

1 M Pressure Guage G For ETmax and h1 see table


1M
Permitted Dimensional Tolerances Technical Data and Dimensions
Centreline heights DIN 747. h2 DN2
Dimensions with no tolerance DIN 7168 m.
Cast iron components DIN 1686 GTB 18 h1

Discharge Flange s
Connection dimensions to DIN 2501, PN 10 250

Flange thickness* to DIN EN 1092--2, PN 6 200


t4
* for operating pressure 6 bar DIN EN 1092--2, PN 10
300
DN2 Permitted drive flange diameters d2 in mm
400 up to 660
500 up to 800
for larger flange see page 17
600 up to 1100 t3
700 up to 1200

Dimensions in mm, non--binding


Pump Pump dimensions
t3
size DN2 ETmin a d1 h1 h2 h3 max t1
400--365 940 550 700
ET
400--405 1040 550 800
400--420 400 1065 400 550 400 750 415 825
t3
400--430 1040 550 740
400--450 1275 600 975
500--505 1180 645 880
500--515 500 1400 500 645 500 870 420 1100 t2
500--620 1330 645 1030
600--535 1310 700 1010
600--550 1345 700 1045
600--575 1515 775 1215
600--600 600 1380 600 775 600 990 420 1080 t1
600--650 1500 775 1200
600--700 1400 750 1100
600--720 1510 750 1210
700--655 1950 900 1550
d1
700--715 700 1630 700 870 700 1125 490 1230
700--755 1860 980 1460 m
25 25 50
Pump Feet dimensions Foundation dimensions
size m n s o1 o2 p1 p2
400--365 950 700 650 750 650 400
400--405 950 700 650 750 650 400 n
400--420 1050 800 30 750 850 750 500
400--430 950 700 650 750 650 400
Plan view
400--450 1050 800 750 850 750 500
500--505 1050 800 30 750 850 750 500 4 holes 27 50
500--515 1050 800 30 750 850 750 500
o1
500--620 1200 940 35 900 1000 900 640
200
600--535
600--550 p1
600--575 1200 940 35 900 1000 900 640
p2
600--600
600--650 Foundation
600--700 1400 1140 1100 1200 1100 840 holes
35 200
600--720 1500 1240 1200 1300 1200 940
o2
700--655
700--715 1400 1140 40 1100 1200 1100 840
700--755

SNW 15
Rev.4, 15.05.2002
Type Series Booklet SNW

DIMENSION TABLES
EB Mounting Arrangement (EBd) -- Floodable version
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request.

Connections
d2
1 M Pressure Guage G For ETmax and h1 see table
8A Leaking liquid outlet G Technical Data and Dimensions h3
Permitted Dimensional Tolerances
Centreline heights DIN 747.
Dimensions with no tolerance DIN 7168 m.
Cast iron components DIN 1686 GTB 18 h2 DN2
h1
Discharge Flange
Connection dimensions to DIN 2501, PN 10
Flange thickness* to DIN EN 1092--2, PN 6
* for operating pressure 6 bar DIN EN 1092--2, PN 10
DN2 Permitted drive flange diameters d2 in mm t4
400 up to 660
500 up to 800
for larger flange see page 18
600 up to 1100
700 up to 1200
t3 350
Dimensions in mm, non--binding
Pump Pump dimensions
size DN2 ETmin a d1 h1 h2 h3 max t1
400--365 950 550 700 t3 100
400--405 1050 550 800
400--420 400 1075 400 550 400 750 415 825
ET
400--430 990 550 740
400--450 1225 600 975 t3
500--505 1130 645 880
500--515 500 1350 500 645 500 870 420 1100
500--620 1280 645 1030
t2
600--535 1260 700 1010
600--550 1295 700 1045
600--575 1465 775 1215
600--600 600 1330 600 775 600 990 420 1080
600--650 1450 775 1200
t1
600--700 1350 750 1100
600--720 1460 750 1210
700--655 1800 900 1550
700--715 700 1480 700 870 700 1125 490 1230
700--755 1710 980 1460 d1

Pump Feet dimensions Foundation dimensions y1 holes x


size d3 d4 s x y1 d5 d6 d7 y2
400--365 750 700 630 960 800
400--405 750 700 630 960 800
400--420 860 800 30 22 8 720 1060 910 8 d3 d4
400--430 750 700 630 960 800
400--450 860 800 720 1060 910 Plan view
500--505 860 800 30 22 8 720 1060 910 8
500--515 860 800 30 22 8 720 1060 910 8
500--620 1080 990 35 26 12 900 1280 1130 12
y2 holes
600--535
600--550
600--575 1080 990 35 26 12 900 1280 1130 12
600--600
600--650 d6 d7 d5

600--700 1250 1150 1050 1550 1270 8


600--720 1450 1350 1250 1750 1470 8
Foundation
700--655
holes
700--715 1250 1150 40 26 12 1050 1450 1300 12
700--755
16 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

DIMENSION TABLES
EK Mounting Arrangement (EKn) Non-- floodable version
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request.

Connections d2

1 M Pressure Guage G For ETmax and h1, see table h3


a
Permitted Dimensional Tolerances Technical Data and Dimensions
Centreline heights DIN 747. 1M
Dimensions with no tolerance DIN 7168 m.
Cast iron components DIN 1686 GTB 18 h2
DN2

Discharge Flange h1

Connection dimensions to DIN 2501, PN 10


s
Flange thickness* to DIN EN 1090--2, PN 6
250
* for operating pressure 6 bar DIN EN 1092--2, PN 10
200
DN2 Permitted drive flange diameters d2 in mm
t4
400 > 660 300
500 > 800
600 > 1100
700 > 1200
t3
Dimensions in mm, non--binding
Pump Pump dimensions
size DN2 ETmin a d1 h1 h2 h3 max t1
400--365 940 550 700 t3
400--405 1040 550 800
400--420 400 1065 400 550 400 750 415 825 ET
400--430 1040 550 740
400--450 1275 600 975 t3
500--505 1180 645 880
500--515 500 1400 500 645 500 870 420 1100
500--620 1330 645 1030
600--535 1310 700 1010 t2

600--550 1345 700 1045


600--575 1515 775 1215
600--600 600 1380 600 775 600 990 420 1080
600--650 1500 775 1200
t1
600--700 1400 750 1100
600--720 1510 750 1210
700--655 1950 900 1550
700--715 700 1630 700 870 700 1125 490 1230
700--755 1860 980 1460 d1

Pump
u p Feet dimensions Foundation dimensions
size m n s o1 o2 p1 p2 m
25 25
400--365 950 700 650 750 650 400
400--405 950 700 650 750 650 400 50

400--420 1050 800 30 750 850 750 500


400--430 950 700 650 750 650 400 n
400--450 1050 800 750 850 750 500
500--505 1050 800 30 750 850 750 500
Plan view 50
500--515 1050 800 30 750 850 750 500
500--620 1200 940 35 900 1000 900 640 4 holes 27

600--535
o1
600--550
200
600--575 1200 940 35 900 1000 900 640
600--600
p1
600--650
p2
600--700 1400 1140 1100 1200 1100 840
Foundation
600--720 1500 1240 1200 1300 1200 940
holes
700--655
200
700--715 1400 1140 40 1100 1200 1100 840 o2
700--755

SNW 17
Rev.4, 15.05.2002
Type Series Booklet SNW

DIMENSION TABLES
EK Mounting Arrangement (EKd) -- Floodable version
The pump is shown without a driver.
All dimensions which relate to the type and size of the driver and installation / structure can be supplied on request.
Pump driven by IEC standard motor with lateral inlet cooling air outlet.
Where the piping is flexibly connected to the discharge elbow, the thrust must be accomodated by suitable means.
Dimensions t2 to t4 and d2 on request.
Connections
1 M Pressure Guage G For ETmax and h1, see table
8 A Leakage fluid outlet G Technical Data and Dimensions
Permitted Dimensional Tolerances
Centreline heights DIN 747 d2
Dimensions with no tolerance DIN 7168 m
Cast iron components DIN 1686 GTB 18 h3 a
1M
Discharge Flange
Connection dimensions to DIN 2501, PN 10 DN2
Flange thickness* to DIN EN 1092--2, PN 6 h2 8A
* for operating pressure 6 bar DIN EN 1092--2, PN 10 h1
DN2 Permitted drive flange diameters d2 in mm s
400 > 660
500 > 800
600 > 1100
t4
700 > 1200
Dimensions in mm, non--binding
Pump Pump dimensions
size DN2 ETmin a d1 h1 h2 h3 max t1 t3 350
400--365 950 550 700
400--405 1050 550 800
400--420 400 1075 400 550 400 750 415 825
t3
400--430 990 550 740
400--450 1225 600 975 100
ET
500--505 1130 640 880
500--515 500 1350 500 645 500 870 420 1100 t3
500--620 1280 646 1030
600--535 1260 700 1010
600--550 1295 700 1045
600--575 1465 775 1215 t2
600--600 600 1330 600 775 600 990 420 1080
600--650 1450 775 1200
600--700 1350 750 1100
600--720 1460 750 1210
700--655 1800 900 1550 t1
700--715 700 1480 700 870 700 1125 490 1230
700--755 1710 980 1460

Pump
u p Feet dimensions Foundation dimensions d1
size d3 d4 s x y1 d5 d6 d7 y2
m
400--365 750 700 630 960 800 25 25
400--405 750 700 630 960 800
400--420 860 800 30 22 8 720 1060 910 8 50

400--430 750 700 630 960 800


400--450 860 800 720 1060 910 n
d4
500--505 860 800 30 22 8 720 1060 910 8 d3
500--515 860 800 30 22 8 720 1060 910 8
50 Plan view
500--620 1080 900 35 26 12 900 1280 1130 12
600--535
4 holes 27 y1 holes x
600--550
y2 holes
600--575 1080 990 35 26 12 900 1280 1130 12
600--600 200

600--650
600--700 1250 1150 1050 1550 1270 8
600--720 1450 1350 1250 1750 1470 8 d6 d7 d5 p2

700--655
700--715 1250 1150 40 26 12 1050 1450 1300 12 V100 Foundation
700--755 200 holes

For dimensions m, n, o2 and p2 refer to page 17


o2

18 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

BEARING ARRANGEMENT
CD Mounting Arrangement

3 4K 4

5K 5 6K

6 7K 7
SNW 19
Rev.4, 15.05.2002
Type Series Booklet SNW

BEARING ARRANGEMENT
EBn and EKn and/or EBd and EKd Mounting Arrangement

2 3K 3 4K

4 5K 5 6K

6 7K 7

20 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--365
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 1480 [1/min] n = 1480 1/min
120
Open
80
4 Impeller
3
40 2
1
0
H--St [m]
35
NR : D2A/ D2I
[mm]
30
4 : 363/ 278
3 : 352/ 254
25 2 : 346/ 239
Qmin 1 : 329/ 200
20

15

10
4
5 3
Eta--St [%] 2
1
0 90

80

70
4
60 3
2
50 1
NPSH [m]
40 16

30 4 14

20 1 12

10 10

0 100 200 300 400 500 600 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 21
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 365


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 1180 [1/min] n = 1180 1/min
60
Open
40 Impeller
4
3
20 2
H--St [m] 1
40 0
NR : D2A/ D2I
[mm]
35
4 : 363/ 278
3 : 352/ 254
30 2 : 346/ 239
1 : 329/ 200
25

20
Qmin
15

10

5
Eta--St [%] 4
2 3
0 90 1

80

70
NPSH [m]
4
60 3 11
2
50 1 10

40 9
4
30 8
1
20 7

10 6

0.00 80 160 240 320 400 480 Q [l/s)

Curves as per ISO 2548C

B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

22 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--365
50 Hz
n = 1480 1/min

Technical data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 50 40
P/n shaft (mat comb 01) 0,15 0,065
Drive coupling size 2) B 225 B 200 B 180
P/n Drive coupling 0,21 0,14 0,092
h4
Thrust bearing size 7220 B. UA 7216 B. UA
h 4 min 1050 912
h 4 max 3) 2140 1918
Bearing arrangement t5max 3) J t5max 3) J
3 2200 0,45 2020 0,39
4K -- -- 2590 0,39 ET

4 3890 0,45 3540 0,39


5K -- -- 4100 0,39 t5
5 5580 0,45 5050 0,39
6K -- -- 5620 0,39
6 7240 0,45 6530 0,39
7K -- -- 7130 0,39
7 -- -- 7890 0,39
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply fugures by 1,12 Mounting arrangement CD

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 50 40
P/n shaft (mat comb 01) 0,15 0,065
Drive coupling size 2) B 225 B 200 B 180
P/n Drive coupling 0,21 0,14 0,092
Thrust bearing size 7220 B. UA 7216 B. UA
Bearing arrangement ETmax3) J ETmax3) J
2 1590 0,46 1410 0,40
3K -- -- 2160 0,40
3 3270 0,46 2920 0,40
4K -- -- 3660 0,40
4 4950 0,46 4420 0,40
5K -- -- 5180 0,40
5 6660 0,46 5940 0,40 ET

6K -- -- 6700 0,40
6 8320 0,46 7460 0,40
7K -- -- 8170 0,40
7 10030 0,46 8930 0,40
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX Mounting arrangement EBn
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12

SNW 23
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 405


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 1480 [1/min] n = 1480 1/min
200
4 Open
150 Impeller
3
100
2
50 1
H--St [m]
70
NR : D2A/ D2I
[mm]
60
4 : 420/ 335
3 : 401/ 297
50 2 : 387/ 266
1 : 372/ 232
Qmin
40

30

20
4
10 3
Eta--St [%] 2
0 90 1

80
4
70 3

60
2 NPSH [m]
50 4 17.5
1
40 15.0

30 12.5
1
20 10.0

10 7.5

0 120 240 360 480 600 720 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

24 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--405
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 1180 [1/min] n = 1180 1/min
100
4 Open
75 Impeller
3
50
2
25 1
H--St [m]
35
NR : D2A/ D2I
[mm]
30
4 : 420/ 335
3 : 401/ 297
25 Qmin 2 : 387/ 266
1 : 372/ 232
20

15

10 4
3
5
Eta--St [%] 2
1
0 90

80

70 4
3 NPSH [m]
60 16
2
50 14
4
1
40 12

30 10

20 8
1
10 6

0 100 200 300 400 500 600 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 25
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 405


50 Hz
n = 1480 1/min
Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50 40
P/n shaft (mat comb 01) 0,28 0,15 0,065
Drive coupling size 2) B 280 B 250 B 225 B 200 B 180
P/n Drive coupling 0,41 0,29 0,21 0,14 0,092
Thrust bearing size 7222 B. UA 7222 B. UA 7222 B. UA h4

h 4 min 1146 1064 1064


h 4 max3) 2298 2155 2155
Bearing arrangement t5max 3) J t5max 3) J t5max 3) J
3 2480 0,88 2300 0,82 2300 0,57
4K -- -- -- -- -- --
ET
4 4330 0,88 3990 0,82 3990 0,57
5K -- -- -- -- -- --
t5
5 6180 0,88 5680 0,82 5680 0,57
6K -- -- -- -- -- --
6 8030 0,88 7340 0,82 7340 0,57
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12 Mounting arrangement CD

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 60 50 40
P/n shaft (mat comb 01) 0,28 0,15 0,065
Drive coupling size 2) B 280 B 250 B 225 B 200 B 180
P/n Drive coupling 0,41 0,29 0,21 0,14 0,092
Thrust bearing size 7222 B. UA 7222 B. UA 7222 B. UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 1850 0,92 1690 0,83 0,58
3K -- -- -- -- -- --
3 3700 0,92 3370 0,83 0,58
4K -- -- -- -- -- --
4 5530 0,92 5050 0,83 0,58
5K -- -- -- -- -- -- ET
5 7390 0,92 6760 0,83 0,58
6K -- -- -- -- -- --
6 9250 0,92 8420 0,83 0,58
7K -- -- -- -- -- --
7 11040 0,92 10130 0,83 0,58
all dimensions in mm, mass moment of inertia J in kgm2
1) Mounting arrangement EKn
For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12

26 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--420
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 1450 [1/min] n = 1450 1/min
200
Open
150
3
Impeller
H--St [m]
55 100 2
1 NR : D2A/ D2I
[mm]
50 50
3 : 427/ 364
2 : 407/ 338
45 1 : 391/ 315

40 Qmin

35

30

25

20
3
15
Eta--St [%] 2
10 90 1

80
3
70 2
NPSH [m]
1
60 16

50 3 14

40 12

30 10
1
20 8

10 6

0 100 200 300 400 500 600 Q [l/s]

Curves as per ISO 2548C

B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 27
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 420


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 1160 [1/min] n = 1160 1/min
100
Open
80 Impeller
3
60
H--St [m] 2
36 40 1
NR : D2A/ D2I
[mm]
32
3 : 427/ 364
2 : 407/ 338
28 1 : 391/ 315
Qmin
24

20

16

12
3

8 2
Eta--St [%]
1
4 90

80
3
70 2
NPSH [m]
1
60 14

50 12

40 10
3
30 8

20 1 6

10 4

0 80 160 240 320 400 480 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

28 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--420
50 Hz
n = 1450 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200 h4

P/n Drive coupling 0,41 0,29 0,21 0,14


Thrust bearing size 7226 B.UA 7226 B.UA
h 4 min 1148 1066
h 4 max3) 2300 2157
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
ET
3 2505 1,19 2325 1,10
4K -- -- -- --
4 4355 1,19 4015 1,10 t5

5K -- -- -- --
5 6205 1,19 5705 1,10
6K -- -- -- --
6 8055 1,19 7365 1,10
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement CD
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1450 1/min, 50 Hz; for n=1160 1/min, 60 Hz, multiply figures by 1,12

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7226 B.UA 7226 B.UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 1870 1.21 1710 1,11
3K -- -- -- --
3 3730 1.21 3400 1,11
4K -- -- -- --
4 5560 1.21 5070 1,11
5K -- -- -- -- ET

5 7420 1.21 6780 1,11


6K -- -- -- --
6 9280 1.21 8440 1,11
7K -- -- -- --
7 11070 1.21 10150 1,11
all dimensions in mm, mass moment of inertia J in kgm2 Mounting arrangement EKn
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1450 1/min, 50 Hz; for n=1160 1/min, 60 Hz, multiply figures by 1,12

SNW 29
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 430


50 HZ
P [kW] Rho = 1000 [kg/m3] n = 1480 [1/min] n = 1480 1/min
250

200 Closed
Impeller
150 4
3
100
H--St [m] 2
1
70
NR : D2A/ D2I
[mm]
60
4 : 425/ 375
3 : 415/ 357
50 2 : 405/ 340
Qmin 1 : 395/ 320
40

30

20
4
10 3
Eta--St [%] 1 2
0 90

80

70
4
3
60 1 2

50
NPSH [m]
40 16
1 4
30 14

20 12

10 10

0 100 200 300 400 500 600 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

30 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--430
60 HZ
P [kW] Rho = 1000 [kg/m3] n = 1180 [1/min] n = 1180 1/min
150
Closed
100 Impeller
4
50 3
2
H--St [m] 1
40 0
NR : D2A/ D2I
[mm]
35
4 : 425/ 375
3 : 415/ 357
30 2 : 405/ 340
Qmin 1 : 395/ 320
25

20

15

10
4
3
5 2
Eta--St [%] 1

0 90

80

70
4
3
60 1 2 NPSH [m]
50 10
1 4
40 9

30 8

20 7

10 6

0 80 160 240 320 400 480 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 31
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 430


50 HZ
n = 1480 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
h4
Thrust bearing size 7322 B.UA 4) 7322 B.UA
7324 B.UA 5)
h 4 min 1163 1076
h 4 max3) 2310 2166
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 2420 1,61 2240 1,52
ET
4K -- -- -- --
4 4270 1,61 3930 1,52
5K -- -- -- -- t5

5 6120 1,61 5620 1,52


6K -- -- -- --
6 7970 1,61 7280 1,52
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12
4) Up to t 5) Up to t Mounting arrangement CD
5 max = 4270 mm 5 max= 7970mm

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7322 B.UA 4) 7322 B.UA
7324 B.UA 5)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 1790 1,63 1630 1,53
3K -- -- -- --
3 3640 1,63 3310 1,53
4K -- -- -- --
4 5470 1,63 4990 1,53
5K -- -- -- --
ET
5 7330 1,63 6700 1,53
6K -- -- -- --
6 9190 1,63 8360 1,53
7K -- -- -- --
7 10980 1,63 10070 1,53
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
Mounting arrangement EKn
3) Figures are valid for n=1480 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12
4) Up to ET max = 5470 mm 5) Upto ET max = 10980mm

32 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--450
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 1450 [1/min] n = 1450 1/min
300
Closed
250 2 Impeller
200
H--St [m] 1
90 150
NR : D2A/ D2I
[mm]
80
2 : 450/ 410
1 : 419/ 362
70

60
Qmin

50

40

30

20
Eta--St [%] 2
1
10 90

80

70

60
2
1
50
NPSH [m]
40 14
2

30 12

20 10
1
10 8

0 120 240 360 480 600 720 Q [l/s]

Curves as per 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 33
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400-- 450


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 1180 [1/min] n = 1180 1/min
200

150 Closed
2
Impeller
100
1

50
H--St [m]
45
NR : D2A/ D2I
[mm]
40
2 : 450/ 410
Qmin 1 : 419/ 362
35

30

25

20

15
Eta--St [%]
2
10 90 1

80

70

60
2 NPSH [m]
1
50 10

40 2 9

30 8

20 7

10 1 6

0 100 200 300 400 500 600 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

34 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 400--450
50 Hz
n = 1450 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60
P/n shaft (mat comb 01) 0,28
Drive coupling size 2) B 280 B 250
P/n Drive coupling 0,41 0,29
h4
Thrust bearing size 7330 B.UA 4)
7334 B.UA 5)
h 4 min 1248
h 4 max3) 2375
Bearing arrangement t5max 3) J t5max3) J t5max3) J
3 2655 2,70 ET
4K -- --
4 4505 2,70
t5
5K -- --
5 6355 2,70
6K -- --
6 8205 2,70
7K -- --
7 -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1450 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,12 Mounting arrangement CD
4) Up to t
5 max = 6355 mm
5) Up to t 6)
5 max = 8205 mm Lubrication intervals and quantities see page 13

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 60
P/n shaft (mat comb 01) 0,28
Drive coupling size 2) B 280 B 250
P/n Drive coupling 0,41 0,29
Thrust bearing size 7330 B.UA 4)
7334 B.UA 5)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2020 2,72
3K -- --
3 3880 2,72
4K -- --
4 5710 2,72
5K -- -- ET

5 7570 2,72
6K -- --
6 9430 2,72
7K -- --
7 11220 2,72
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EKn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=1450 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 1,11
4) Up to ET max = 7570 mm 5) Up to ETmax = 11220

SNW 35
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500-- 505


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 980 1/min
160

120 4 Open
3
2 Impeller
80
H--St [m] 1
36 40
NR : D2A/ D2I
[mm]
32
4 : 500/ 428
3 : 489/ 407
28 Qmin 2 : 474/ 376
1 : 448/ 320
24

20

16

12
4
8 3
Eta--St [%] 2
1
4 90

80

70
NPSH [m]
2 34
60 1 18

4
50 16

40 14

30 12

20 10
1

10 8

0 160 320 480 640 800 960 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

36 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500--505
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 880 [1/min] n = 880 1/min
160
Open
120 Impeller
4
80 3
H--St [m] 2
36 40 1
NR : D2A/ D2I
[mm]
32
4 : 500/ 428
3 : 489/ 407
28 2 : 474/ 376
1 : 448/ 320
24
Qmin
20

16

12

8
Eta--St [%] 3 4
2
4 90 1

80

70
2 3 4
60 1
NPSH [m]
50 14
4
40 12

30 10

20 1 8

10 6

0 400 800 1200 1600 2000 2400 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 37
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500-- 505


50 Hz
n = 980 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
h4
Thrust bearing size 7222 B.UA 4) 7222 B.UA
7226 B.UA 5)
h 4 min 1182 1084
h 4 max3) 2750 2556
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 2940 2,11 2740 2,02
ET
4K 3630 2,11 3430 2,02
4 5210 2,11 4820 2,02
5K 5900 2,11 5500 2,02 t5

5 7480 2,11 6890 2,02


6K 8140 2,11 7550 2,02
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
4) Up to t
Mounting arrangement CD
5 max = 3630 mm 5) Up to t5 max = 8140mm

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 4) 7222 B.UA
7226 B.UA 5)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2230 2,12 2030 2,03
3K 3100 2,12 2900 2,03
3 4490 2,12 4100 2,03
4K 5360 2,12 4960 2,03
4 6770 2,12 6170 2,03
5K 7630 2,12 7030 2,03 ET
5 9040 2,12 8240 2,03
6K 9900 2,12 9100 2,03
6 11310 2,12 10310 2,03
7K -- -- 11170 2,03
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EBn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
4) Up to ET 5) Upto ETmax = 11310
max = 5360 mm

38 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500--515
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 960 [1/min] n = 960 1/min
200
Open
150 Impeller
100 4
3
2
50
H--St [m] 1
35
NR : D2A/ D2I
[mm]
30
4 : 502/ 345
3 : 482/ 329
25 2 : 463/ 309
Qmin 1 : 443/ 274
20

15

10 4
3
5 2
Eta--St [%]
1
0 90

80 4
3
70 2
NPSH [m]
1
60 16

50 14
4

40 12

30 10

20 8

10 6

0 150 300 450 600 750 900 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 39
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500-- 515


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 875 [1/min] n = 875 1/min
240

160 Open
4
Impeller
80
3
2
1
0
NR:D2A/D2I(mm)
4: 502/345
H--St [m]
30
3: 482/329
2: 463/309
25
1: 443/274
20

15

10
4
5 3
Eta--St [%] 2
1
0 90

80
4
3
70 2
1 NPSH [m]
60 16

50 4 14

40 12

30 10

20 8

10 6

0 150 300 450 600 750 900 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

40 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500--515
50 Hz
n = 960 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14 h4

Thrust bearing size 7222 B.UA 7220 B.UA 4)


7222 B.UA 5)
h 4 min 1180 1084
h 4 max 3) 2750 2552
Bearing arrangement t5max3) J t5max3) J t5max3) J
3 3160 1,77 2960 1,69 ET

4K 3850 1,77 3650 1,69


4 5430 1,77 5040 1,69
t5
5K 6120 1,77 5720 1,69
5 7700 1,77 7110 1,69
6K -- -- 7700 1,69
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Mounting arrangement CD
Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,05
4) Up to t5 max = 5040 mm
5) Up to t5 max = 7770 mm

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 60 50
P/n shaft (mat comb 01) 0,28 0,15
Drive coupling size 2) B 280 B 250 B 225 B 200
P/n Drive coupling 0,41 0,29 0,21 0,14
Thrust bearing size 7222 B.UA 7220 B.UA 4)
7222 B.UA 5)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2450 1,80 2250 1,70
3K 3320 1,80 3120 1,70
3 4710 1,80 4320 1,70
4K 5580 1,80 5180 1,70
4 6990 1,80 6390 1,70
ET
5K 7850 1,80 7250 1,70
5 9260 1,80 8460 1,70
6K 10120 1,80 9320 1,70
6 11530 1,80 10530 1,70
7K -- -- 11390 1,70
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2 Mounting arrangement EBn
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,05
4) Up to ET
max = 6390 mm
5) Up to ET
max = 11390 mm

SNW 41
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500-- 620


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 980 [1/min] n = 980 1/min
400

300 4 Closed
3
2
Impeller
200
1
100

H--St [m]
70
NR : D2A/ D2I
[mm]
60
4 : 610/ 570
3 : 585/ 531
50 Qmin 2 : 562/ 495
1 : 540/ 462
40

30
4
20 3
Eta--St [%] 2
1
10 90

80
4
3
70 2
1
60
NPSH [m]
50 14
4
40 12
1
30 10

20 8

10 6

0 150 300 450 600 750 900 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

42 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500--620
60 Hz
n = 875 1/min

Closed
Impeller
H--St [m]

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 43
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 500-- 620


50 Hz
n = 980 1/min
Technical Data and Dimensions
Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
h4
Thrust bearing size 7336 B. UA 7334 B. UA 4) 7330 B. UA
7336 B. UA 5)
h 4 min 1523 1401 1257
h 4 max 3) 3186 3018 2827
Bearing arrangement t5max3) J t5max3) J t5max3) J
3 3460 6,21 3290 6,05 3090 5,86
ET
4K -- -- -- -- 3780 5,86
4 6080 6,21 5740 6,05 5360 5,86
5K -- -- -- -- 6050 5,86 t5

5 -- -- -- 7630 5,86
6K -- -- -- -- -- --
6 -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 0,91
4) Up to t Mounting arrangement CD
5 max = 3290 mm
5) Up to t
5 max = 5740 mm

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A A 315 A 315 B 280 B 280 B 250
350
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
Thrust bearing size 7334 B. UA 4) 7334 B. UA 6) 7328 B. UA 8)
7336 B. UA 5) 7336 B. UA 7) 7336 B. UA 9)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2730 6,21 2560 6,11 2380 5,89
3K -- -- -- -- 3250 5,89
3 5350 6,21 5010 6,11 4640 5,89
4K -- -- -- -- 5510 5,89
4 7960 6,21 7440 6,11 6920 5,89 ET
5K -- -- -- -- 7780 5,89
5 -- 9900 6,11 9190 5,89
6K -- -- -- -- 10050 5,89
6 -- -- -- 11460 5,89
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2 Mounting arrangement EKn
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=1180 1/min, 60 Hz, multiply figures by 0,91
4) Up to ET 5) Up to ET 6) Up to ET
max = 2730 mm, max = 7960 mm, max = 5010 mm
7) Up to ET 8) Up to ET 9) Up to ET
max = 9900 mm, max = 3250 mm, max = 11460 mm

44 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--535
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 980 [1/min] n = 980 1/min
300

200 Open
4 Impeller
100
H--St [m] 2 3
1
32 0
NR : D2A/ D2I
[mm]
28
4 : 531/ 409
3 : 520/ 384
24 2 : 504/ 343
1 : 485/ 301
Qmin
20

16

12

8
4
4 3
Eta--St [%] 2
1
0 90

80

70
4
60 3
2
50 1
NPSH [m]
40 14

30 4 12

1
20 10

10 8

0 200 400 600 800 1000 1200 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 45
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 535


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 880 [1/min] n = 880 1/min
200

150 Open
Impeller
100 4
3
2
50
H--St [m] 1
28
NR : D2A/ D2I
[mm]
24
4 : 531/ 409
3 : 520/ 384
20 2 : 504/ 343
Qmin 1 : 485/ 301
16

12

4 4
3
Eta--St [%] 2
1
0 90

80

70
4
60 3
2 NPSH [m]
50 1 11

40 4 10

30 9
1
20 8

10 7

0 200 400 600 800 1000 1200 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

46 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--535
50 Hz
n = 980 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 70 60
P/n shaft (mat comb 01) 0,46 0,28
Drive coupling size 2) A 315 B 280 B 280 B 250
P/n Drive coupling 0,58 0,41 0,41 0,29
h4
Thrust bearing size 7226 B.UA 7226 B.UA
h 4 min 1366 1252
h 4 max 3) 2986 2822
Bearing arrangement t5max 3) J t5max3) J t5max3) J
3 3250 2,33 3050 2,26
4K 4040 2,33 3860 2,26 ET

4 5700 2,33 5320 2,26


5K 6490 2,33 6130 2,26 t5
5 -- -- 7590 2,26
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06 Mounting arrangement CD

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 70 60
P/n shaft (mat comb 01) 0,46 0,28
Drive coupling size 2) A 315 B 280 B 280 B 250
P/n Drive coupling 0,58 0,41 0,41 0,29
Thrust bearing size 7226 B.UA 7226 B.UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2410 2,39 2230 2,29
3K 3410 2,39 3230 2,29
3 4870 2,39 4500 2,29
4K 5840 2,39 5480 2,29
4 7300 2,39 6750 2,29
5K 8310 2,39 7760 2,29
ET
5 9770 2,39 9020 2,29
6K 10730 2,39 10030 2,29
6 -- -- 11290 2,29
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EKn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06

SNW 47
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 550


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 980 [1/min] n = 980 1/min
300

250 Open
4 Impeller
200
3
150 2
H--St [m]
1
40
NR : D2A/ D2I
[mm]
35 Qmin 4 : 557/ 483
3 : 543/ 452
30 2 : 534/ 433
1 : 513/ 388
25

20

15
4
10 3
Eta--St [%] 2
1
5 90

80

70
NPSH [m]
2 34
60 1 22.5

50 4 20.0

40 17.5

30 15.0

20 12.5
1
10 10.0

0 200 400 600 800 1000 1200 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

48 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--550
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 880 [1/min] n = 880 1/min
200

160
4 Open
3 Impeller
120
H--St [m] 2
36 80 1
NR : D2A/ D2I
[mm]
32
4 : 557/ 483
3 : 543/ 452
28 Qmin 2 : 534/ 433
1 : 513/ 388
24

20

16

12
4
8 3
Eta--St [%] 2
1
4 90

80

70
2 3 4
60 1
NPSH [m]
50 4 16

40 14

30 12

20 10
1
10 8

0 160 320 480 640 800 960 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 49
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 550


50 Hz
n = 980 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
h4
Thrust bearing size 7236 B.UA 7324 B.UA 7322 B.UA
h 4 min 1493 1381 1262
h 4 max 3) 3188 2996 2832
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 3455 4,11 3285 3,84 3085 3,76
4K -- -- 4075 3,84 3895 3,76 ET

4 6075 4,11 5735 3,84 5355 3,76


5K -- -- 6525 3,84 6165 3,76 t5
5 -- -- -- 7625 3,76
6K -- -- -- -- -- --
6 -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
Mounting arrangement CD

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
Thrust bearing size 7236 B.UA 7) 7322 B.UA 4) 7) 7322 B.UA 7)
7324 B.UA 5) 7)
7326 B.UA 6) 7)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2620 4,21 2450 3,91 2270 3,78
3K -- -- 3440 3,91 3260 3,78
3 5240 4,24 4900 3,91 4530 3,78
4K -- -- 5880 3,91 5520 3,78
4 7850 4,21 7340 3,91 6790 3,78
5K -- -- 8350 3,91 7800 3,78
ET
5 10460 4,21 9810 3,91 9060 3,78
6K -- -- 10770 3,91 10070 3,78
6 -- -- -- -- 11330 3,78
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EKn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
4) Up to ET max = 3440 mm, 5) Up to ET max = 9810 mm, 6) Up to ET max = 10770 mm
7) Lubrication intervals and quantities see page 13
50 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--575
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 960 [1/min] n = 960 1/min
300

250 Open Impeller


200
3

150 2
1
H--St [m]
36
NR : D2A/ D2I
[mm]
32
3 : 547/ 429
2 : 535/ 393
28 Qmin 1 : 524/ 356

24

20

16

12
Eta--St [%] 3
1 2
8 90

80
2 3
70 1

60
NPSH [m]
50 14
3
40 12

30 10
1
20 8

10 6

0 200 400 600 800 1000 1200 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 51
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 575


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 875 [1/min] n = 875 1/min
250

200
Open
150 3 Impeller
2
100 1
H--St [m]
40
NR : D2A/ D2I
[mm]
35
3 : 547/ 429
2 : 535/ 393
30 1 : 524/ 356

25 Qmin

20

15

10
Eta--St [%] 3
1 2
5 90

80
2 3
70 1
NPSH [m]
60 11
3
50 10

40 9

30 1 8

20 7

10 6

0 200 400 600 800 1000 1200 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

52 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--575
50 Hz
n = 960 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
h4
Thrust bearing size 7236 B.UA 7324 B.UA 7322 B.UA 4)
7324 B.UA 5)
h 4 min 1493 1381 1262
h 4 max3) 3188 2996 2832
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 3625 3,31 3455 3,04 3255 2,97
ET
4K -- -- 4245 3,04 4065 2,97
4 6245 3,31 5905 3,04 5525 2,97
5K -- -- 6695 3,04 6335 2,97 t5

5 -- -- -- -- 7795 2,97
6K -- -- -- -- -- --
6 -- -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,05
4) Mounting arrangement CD
Up to t5 max = 6335 mm, 5) Up to t5 max = 7795 mm

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 80 70 60
P/n shaft (mat comb 01) 0,72 0,46 0,28
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280 B 280 B 250
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41 0,41 0,29
Thrust bearing size 7236 B.UA 9) 7322 B.UA 4) 7322 B.UA 7)
7324 B.UA 5) 7324 B.UA 8)
7326 B.UA 6)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2790 3,42 2620 3,11 2440 2,99
3K -- -- 3610 3,11 3430 2,99
3 5410 3,42 5070 3,11 4700 2,99
4K -- -- 6050 3,11 5690 2,99
4 8020 3,42 7510 3,11 6960 2,99
5K -- -- 8520 3,11 7970 2,99 ET

5 10630 3,42 9980 3,11 9230 2,99


6K -- -- 10940 3,11 10240 2,99
6 -- -- -- -- 11500 2,99
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EBn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=960 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,05
4) Up to ET 5) Up to ET 6) Up to ET
max = 3610 mm, max = 8520 mm, max = 10940 mm
7) Up to ET 8) Up to ET
max = 7970 mm, max = 11500 mm

SNW 53
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 600


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 980 [1/min] n = 980 1/min
400

300 4 Open
3
2 Impeller
200
H--St [m] 1
45 100
NR : D2A/ D2I
[mm]
40 Qmin 4 : 605/ 525
3 : 583/ 481
35 2 : 561/ 433
1 : 536/ 375
30

25

20

15
4
3
10 2
Eta--St [%] 1
5 90

80

70
2 3 4
60 1
NPSH [m]
50 30

40 25
4
30 20

20 15
1
10 10

0 240 480 720 960 1200 1440 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

54 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--600
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 880 [1/min] n = 880 1/min
300

250 Open
4 Impeller
200 3
2
150
H--St [m] 1
40
NR : D2A/ D2I
[mm]
35
4 : 605/ 525
Qmin 3 : 583/ 481
30 2 : 561/ 433
1 : 536/ 375
25

20

15

10 4
3
Eta--St [%] 2
1
5 90

80

70
2 3 4
60 1

50
NPSH [m]
40 20
4
30 16

20 12
1
10 8

0 200 400 600 800 1000 1200 Q [l/s]

Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 55
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 600


50 Hz
n = 980 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
h4
Thrust bearing size 7334 B.UA 7334 B.UA
h 4 min 1511 1418
h 4 max 3) 3206 3038
Bearing arrangement t5max 3) J t5max3) J t5max3) J
3 3490 5,61 3320 5,48
4K -- -- 4110 5,48 ET

4 6110 5,61 5770 5,48


5K -- -- 6560 5,48 t5
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06 Mounting arrangement CD

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7334 B.UA 6) 7330 B.UA 4)
7334 B.UA 5)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2650 5,72 2480 5,54
3K -- -- 3480 5,54
3 5270 5,72 4940 5,54
4K -- -- 5910 5,54
4 7880 5,72 7370 5,54
5K -- -- 8380 5,54
ET
5 10490 5,72 9840 5,54
6K -- -- 10800 5,54
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EBn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06
4) Up to ET max = 2480 mm, 5) Up to ET max = 10800 mm

56 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--650
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 990 [1/min] n = 990 1/min
500
2
400 Closed
Impeller
300 1
H--St [m]
100 200
NR : D2A/ D2I
[mm]
90
2 : 647/593
1 : Dm=565
80

70

60
Qmin
50

40

30
Eta--St [%] 2
1
20 90

80
2
70 1
NPSH [m]
60 13
2

50 12

40 11

1
30 10

20 9

10 8

0 200 400 600 800 1000 1200 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 57
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 650


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 875 [1/min] n = 875 1/min
350

300 2 Closed
Impeller
250
1
200
H--St [m]
50
NR : D2A/ D2I
[mm]
45
2 : 647/ 593
Qmin 1 : Dm=565
40

35

30

25
2
20
Eta--St [%] 1
15 90

80
2
70 1
NPSH [m]
60 11

50 2 10

40 9

30 1 8

20 7

10 6

0 160 320 480 640 800 960 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

58 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--650
50 Hz
n = 990 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
h4
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max 3) 3264 3065
Bearing arrangement t5max 3) J t5max3) J t5max3 J
)

3 3610 9,14 3440 8,97 ET


4K -- -- 4230 8,97
4 6230 9,14 5890 8,97
t5
5K -- -- 6680 8,97
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX Mounting arrangement CD
3) Figures are valid for n=990 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,06

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2770 9,31 2600 9,05
3K -- -- 3600 9,05
3 5390 9,31 5060 9,05
4K -- -- 6030 9,05
4 8000 9,31 7490 9,05
5K -- -- 8500 9,05 ET
5 10610 9,31 9960 9,05
6K -- -- 10920 9,05
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2 Mounting arrangement EKn
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=990 1/min, 50 Hz; for n=875 1/min, 60 Hz, multiply figures by 1,06

SNW 59
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 700


50 Hz
n = 980 1/min

Closed
Impeller

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

60 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--700
60 Hz
n = 880 1/min

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 61
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 700


50 Hz
n = 980 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
h4
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max3) 3264 3065
Bearing arrangement t5max 3) J t5max3) J t5max3) J
3 3610 16,5 3440 14,77
4K -- -- 4230 14,77 ET
4 6230 16,5 5890 14,77
5K -- -- 6680 14,77
t5
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06 Mounting arrangement CD

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2770 16,7 2600 14,8
3K -- -- 3600 14,8
3 5390 16,7 5060 14,8
4K -- -- 6030 14,8
4 8000 16,7 7490 14,8
5K -- -- 8500 14,8
5 10610 16,7 9960 14,8
ET
6K -- -- 10920 14,8
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX Mounting arrangement EKn
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06

62 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--720
50 Hz
n = 980 1/min

Closed
Impeller

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 63
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600-- 720


60 Hz
n = 880 1/min

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

64 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 600--720
50 Hz
n = 980 1/min

Technical Data and Dimensions

Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
h4
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
h 4 min 1583 1451
h 4 max 3) 3264 3065
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 3610 17,4 3440 15,7
4K -- -- 4230 15,7 ET

4 6230 17,4 5890 15,7


5K -- -- 6680 15,7 t5
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06 Mounting arrangement CD

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 2 x 7240 B.UA 2 x 7240 B.UA
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 2770 17,9 2600 16,2
3K -- -- 3600 16,2
3 5390 17,9 5060 16,2
4K -- -- 6030 16,2
4 8000 17,9 7490 16,2
5K -- -- 8500 16,2
5 10610 17,9 9960 16,2 ET

6K -- -- 10920 16,2
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Mounting arrangement EKn
Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=980 1/min, 50 Hz; for n=880 1/min, 60 Hz, multiply figures by 1,06

SNW 65
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700-- 655


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 735 [1/min] n = 735 1/min
450

300
4
Open
3 Impeller
150 2
H--St [m] 1
40 0
NR : D2A/ D2I
[mm]
35
4 : 704/ 486
3 : 689/ 467
30 2 : 675/ 440
1 : 656/ 404
25 Qmin

20

15

10 4
3
5 2
Eta--St [%] 1
0 90

80 4
3
70
2

60 1
NPSH [m]
50 16
4
40 14

30 1 12

20 10

10 8

0 300 600 900 1200 1500 1800 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

66 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700--655
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 710 [1/min] n = 710 1/min
400

300 Open
4 Impeller
200 3
2
100
H--St [m] 1
35
NR : D2A/ D2I
[mm]
30
4 : 704/ 486
3 : 689/ 467
25 Qmin 2 : 675/ 440
1 : 656/ 404
20

15

10 4
3
5 2
Eta--St [%]
1
0 90

80 4
3
70 2

60 1
NPSH [m]
50 4 14

40 12
1
30 10

20 8

10 6

0 300 600 900 1200 1500 1800 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 67
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700-- 655


50 Hz
n = 735 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
h4
Thrust bearing size 7328 B.UA 4) 7328 B.UA
7330 B.UA 5)
h 4 min 1553 1435
h 4 max 3) 3648 3429
Bearing arrangement t5max 3) J t5max3) J t5max3) J
3 4310 8,70 4120 8,57 ET

4K 5250 8,70 5060 8,57


4 -- ---- 6940 8,57 t5
5K -- -- -- --
5 -- -- -- --
6K -- -- -- --
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2,
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
Mounting arrangement CD
3) Figures are valid for n=735 1/min, 50 Hz; for n=710 1/min, 60 Hz, multiply figures by 1,02
4) Up to t 5) Up to t
5 max = 4310 mm, 5 max = 5250 mm

Mounting arrangement EBn / EBd


Material combination 1) 01
Shaft diameter 80 70
P/n shaft (mat comb 01) 0,72 0,46
Drive coupling size 2) A 400 A 350 A 315 A 315 B 280
P/n Drive coupling 1,1 0,81 0,58 0,58 0,41
Thrust bearing size 7328 B.UA 4) 7328 B.UA 6)
7330 B.UA 5) 7330 B.UA 7)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 3390 8,83 3190 8,64
3K 4510 8,83 4320 8,64
3 6410 8,83 6020 8,64
4K 7520 8,83 7130 8,64
4 9430 8,83 8840 8,64
5K 10540 8,83 9950 8,64 ET

5 -- -- 11660 8,64
6K -- -- -- 8,64
6 -- -- -- --
7K -- -- -- --
7 -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4 Mounting arrangement EBn
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=735 1/min, 50 Hz; for n=710 1/min, 60 Hz, multiply figures by 1,02
4) Up to ET 5) Up to ET 6) Up to ET
max = 6410 mm, max = 6410 mm, max = 9950 mm
7) Up to ET
max = 11660 mm

68 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700--715
50 Hz
P [kW] Rho = 1000 [kg/m3] n = 725 [1/min] n = 725 1/min
350

300
4 Open
250
H--St [m]
3 Impeller
36 200 2
NR : D2A/ D2I
1 [mm]
32
Qmin 4 : 704/ 606
3 : 681/ 548
28 2 : 654/ 483
1 : 633/ 419
24

20

16

12
4
3
8 2
Eta--St [%] 1
4 90

80

70
2 3 4
1
60
NPSH [m]
50 4 17.5

40 15.0

30 12.5

20 10.0

10 7.5

0 250 500 750 1000 1250 1500 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

SNW 69
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700-- 715


60 Hz
P [kW] Rho = 1000 [kg/m3] n = 700 [1/min] n = 700 1/min
400

300 Open
4 Impeller
200 3
H--St [m] 2
1
36 100
NR : D2A/ D2I
[mm]
32
4 : 704/ 606
Qmin 3 : 681/ 548
28 2 : 654/ 483
1 : 633/ 419
24

20

16

12
4
8 3
Eta--St [%] 2
1
4 90

80

70
2 34 NPSH [m]
1
60 18

4
50 16

40 14

30 12

20 10

10 8

0 300 600 900 1200 1500 1800 Q [l/s]


Curves as per ISO 2548C

A = EB 7 ; EB 7K
B = CD 7 ; CD 7K ; EB 6; EB 6K
C = CD 6 ; CD 6K ; EB 5; EB 5K
D = CD 5 ; CD 5K ; EB 4; EB 4K
E = CD 4 ; CD 4K ; EB 3; EB 3K
F = CD 3 ; EB 2
Typical Pump Designation:--
EB 5K

Bearing arrangement
Mounting arrangement

70 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700--715
50 Hz
n = 725 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
P/n Drive coupling 1,70 1,40 1,40 1,10 0,81 1,10 0,81 0,58
h4
Thrust bearing size 7334 B.UA 7334 B.UA 7334 B.UA
h 4 min 1602 1469 1572
h 4 max 3) 4042 3848 3663
Bearing arrangement t5max3) J t5max3) J t5max3) J
3 4350 12,82 4170 12,23 3990 12,14
4K 5290 12,82 5120 12,23 4930 12,14
ET
4 -- -- -- ---- 7020 12,14
5K -- -- -- -- -- --
t5
5 -- -- -- -- -- --
6K -- -- -- -- -- --
6 -- -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,02
Mounting arrangement CD
Mounting arrangement EBn / EBd
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
P/n Drive coupling 1,70 1,40 1,40 1,10 0,81 1,1 0,81 0,58
Thrust bearing size 7330 B.UA 4) 7330 B.UA 6) 7330 B.UA 8)
7334 B.UA 5) 7334 B.UA 7) 7334 B.UA 9)
Bearing arrangement ETmax3) J ETmax3) J ETmax3) J
2 3420 13,14 3250 12,42 3070 12,20
3K 4550 13,14 4380 12,42 4190 12,20
3 6810 13,14 6450 12,42 6090 12,20
4K 7920 13,14 7570 12,42 7200 12,20
4 10180 13,14 9650 12,42 9110 12,20
5K 11290 13,14 10760 12,42 10220 12,20
5 -- -- -- -- -- -- ET
6K -- -- -- -- -- --
6 -- -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX Mounting arrangement EBn
3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,02
4) Up to ET max = 4550 mm, 5) Up to ET max = 11290 mm, 6) Up to ET max = 4380 mm
7) Up to ET max = 10760 mm, 8) Up to ET max = 4190 mm, 9) Up to ET max = 10220 mm

SNW 71
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700-- 755


50 Hz
P [kW] Rho = 1000 [kg/m3] n = 725 [1/min] n = 725 1/min
600

4
400 Open
3
Impeller
200 2
1
0

H--St [m]
48
NR : D2A/ D2I
[mm]
40
4 : 776/ 607
Qmin 3 : 747/ 552
32 2 : 717/ 488
1 : 694/ 426
24

16
4
3
8
Eta--St [%] 2
1
0 90

80 4
3
70
2
60
NPSH [m]
50 1 16
4
40 14

30 12

20 10
1
10 8

0 400 800 1200 1600 2000 2400 Q [l/s]


Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

72 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700--755
60 Hz
P [kW] Rho = 1000 [kg/m3] n = 700 [1/min] n = 700 1/min
600

400 4 Open
3 Impeller
200 2
H--St [m] 1
40 0
NR : D2A/ D2I
[mm]
35
4 : 776/ 607
Qmin 3 : 746/ 552
30 2 : 717/ 488
1 : 694/ 426
25

20

15
4
10 3

5 2
Eta--St [%]
1
0 90

80 4
3
70
2
60
NPSH [m]
50 1 14
4

40 12

30 10
1
20 8

10 6

0 400 800 1200 1600 2000 2400 Q [l/s]

Curves as per ISO 2548C

A = EK 7 ; EK 7K
B = CD 7 ; CD 7K ; EK 6; EK 6K
C = CD 6 ; CD 6K ; EB 5; EK 5K
D = CD 5 ; CD 5K ; EB 4; EK 4K
E = CD 4 ; CD 4K ; EB 3; EK 3K
F = CD 3 ; EK 2
Typical Pump Designation:--
EK 5K

Bearing arrangement
Mounting arrangement

SNW 73
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 700-- 755


50 Hz
n = 725 1/min

Technical Data and Dimensions


Mounting arrangement CD
Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
P/n Drive coupling 1,70 1,40 1,40 1,10 0,81 1,10 0,81 0,58
h4
Thrust bearing size 7336 B.UA 4) 7336 B.UA 7334 B.UA
7338 B.UA 5)
h 4 min 1603 1467 1567
h 4 max3) 4037 3850 3665
Bearing arrangement t5max 3) J t5max 3) J t5max3) J
3 4580 14,69 4400 14,07 4220 13,90
ET
4K 5520 14,69 5350 14,07 5160 13,90
4 -- -- -- ----
t5
5K -- -- -- -- -- --
5 -- -- -- -- -- --
6K -- -- -- -- -- --
6 -- -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,02
4)
Mounting arrangement CD
Up to t5 max = 4580 mm, 5) Up to t5 max = 5520 mm

Mounting arrangement EKn / EKd


Material combination 1) 01
Shaft diameter 100 90 80
P/n shaft (mat comb 01) 1,26 0,87 0,72
Drive coupling size 2) A 480 A 440 A 440 A 400 A 350 A 400 A 350 A 315
P/n Drive coupling 1,70 1,40 1,40 1,10 0,81 1,1 0,81 0,58
Thrust bearing size 7334 B.UA 4) 7334 B.UA 7) 7334 B.UA 10)
7336 B.UA 5) 7336 B.UA 8) 7336 B.UA 11)
7338 B.UA 6) 7338 B.UA 9)
Bearing arrangement ETmax 3) J ETmax3) J ETmax3) J
2 3650 15,01 3480 14,29 3300 14,04
3K 4780 15,01 4610 14,29 4420 14,04
3 7040 15,01 6680 14,29 6320 14,04
4K 8150 15,01 7800 14,29 7430 14,04
4 10410 15,01 9880 14,29 9340 14,04
ET
5K 11520 15,01 10990 14,29 10450 14,04
5 -- -- -- -- -- --
6K -- -- -- -- -- --
6 -- -- -- -- -- --
7K -- -- -- -- -- --
7 -- -- -- -- -- --
all dimensions in mm, mass moment of inertia J in kgm2 Mounting arrangement EKn
1) For material combinations 02, 03, 04 multiply P/n shaft by factor 1,4
2) Drive coupling FLENDER N--EUPEX
3) Figures are valid for n=725 1/min, 50 Hz; for n=700 1/min, 60 Hz, multiply figures by 1,02
4) Up to ET 5) Up to ET 6) Up to ET 7) Up to ET
max = 4780 mm, max = 7040 mm, max = 11520 mm, max = 4610 mm,
8) Up to ET 9) Up to ET 10) Up to ET 11) Up to ET
max = 9880mm, max = 10990 mm, max = 6320 mm, max = 10450 mm

74 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Recommended Spare Parts


for five years operation

No. of pumps including stand--by pumps


Part No. Part designation
g 2 3 4 5 6 8 10 and above
No. of spare parts
233 Impeller 1 1 1 2 2 3 30 %
211, 212, Shafting with keys,
1 1 1 2 2 3 30 %
213, 86--2 etc screws etc, and shaft coupling
502 Casing wear ring 4 4 4 6 6 6 50 %
524 Shaft protecting sleeve, stuffing box 2 2 2 3 3 4 50 %
524 Shaft protecting sleeve, bearings available at short notice
303 Guide bearing available at short notice
454 Set stuffing box rings 1 1 2 2 3 4 50 %
320 Anti--friction bearings 1 1 2 2 3 4 50 %
Set of seals 4 6 8 8 9 12 100 %
Set of coupling membrane pack / elements 1 1 2 2 3 4 50 %

for two years operation

No. of pumps including stand--by pumps


Part No. Part designation
g 2 3 4 5 6 8 10 and above
No. of spare parts
524 Shaft protecting sleeve, stuffing box 2 2 2 3 3 4 50 %
454 Set stuffing box rings 1 1 2 2 3 4 50 %
Set of seals/ O rings 4 6 8 8 9 12 100 %

SNW 75
Rev.4, 15.05.2002
Type Series Booklet SNW

Sectional View
CD Mounting Arrangement

Secured with LOCTITE, type 221


Part no Part Designation
Secured with LOCTITE, type 270

Glued with LOCTITE, type 307

Liquid seal

Lubricant ALTEMP Q NB 50

138 Bellmouth
144 Discharge elbow
171 Diffuser
211 Pump shaft
212.1 Intermediate shaft
212.2 Intermediate shaft
213 Top shaft
233 Counter clock--wise
impeller
303.1 Guide bearing
303.2 Guide bearing
303.3 Guide bearing
320 Anti friction bearing
341 Motor stool
350 Bearing housing
360 Bearing cover
411 Joint ring
412 O--ring
500 Ring
501 Segmental ring
502 Casing wear ring
524.1 Shaft protecting sleeve
524.2 Shaft protecting sleeve
524.3 Shaft protecting sleeve
524.4 Shaft protecting sleeve
524.5 Shaft protecting sleeve
525.1 Spacer sleeve
525.2 Spacer sleeve
525.3 Spacer sleeve
525.4 Spacer sleeve
711.1 Column pipe
711.2 Column pipe
711.3 Column pipe
723 Flange
840 Coupling
86--2 Coupling sleeve
898 Foundation block
920 Nut
920.39 Impeller nut

76 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

Sectional View
EB Mounting Arrangement
non--floodable version

Secured with LOCTITE, type 221

Part no.
Secured with LOCTITE, type 270
Part Designation

Glued with LOCTITE, type 307

Liquid seal

Lubricant ALTEMP Q NB 50

138 Bellmouth
144 Discharge elbow
171 Diffuser
211 Pump shaft
212.1 Intermediate shaft
213 Top shaft
233 Counter clock--wise
impeller
303.1 Guide bearing
303.2 Guide bearing
303.3 Guide bearing
303.4 Guide bearing
320 Anti friction bearing
341 Motor stool
350 Bearing housing
360 Bearing cover
411 Joint ring
412.1 O--ring
412.2 O--ring
412.3 O--ring
452 Gland cover
454 Stuffing box ring
412.3 O--ring
500 Ring
501 Segmental ring
502 Casing wear ring
506 Retaining ring
524.1 Shaft protecting sleeve
524.2 Shaft protecting sleeve
524.3 Shaft protecting sleeve
524.4 Shaft protecting sleeve
524.5 Shaft protecting sleeve
525.1 Spacer sleeve
525.2 Spacer sleeve
525.3 Spacer sleeve
525.4 Spacer sleeve
711.1 Column pipe
711.2 Column pipe
840 Coupling
86--2 Coupling sleeve
891 Foundation ring
920 Nut
920.39 Impeller nut

SNW 77
Rev.4, 15.05.2002
Type Series Booklet SNW

Sectional View
EB Mounting Arrangement
floodable version Secured with LOCTITE, type 221

Secured with LOCTITE, type 270

Part no.
Part Designation Glued with LOCTITE, type 307

Pressure--tight fitting

Liquid seal

Lubricant ALTEMP Q NB 50

138 Bellmouth
144 Discharge elbow
171 Diffuser
211 Pump shaft
212.1 Intermediate shaft
213 Top shaft
233 Counter clock--wise
impeller
303.1 Guide bearing
303.2 Guide bearing
303.3 Guide bearing
303.4 Guide bearing
320 Anti friction bearing
341 Motor stool
350 Bearing housing
360 Bearing cover
411 Joint ring
412.1 O--ring
412.2 O--ring
412.3 O--ring
452 Gland cover
454 Stuffing box ring
412.3 O--ring
500 Ring
501 Segmental ring
502 Casing wear ring
506 Retaining ring
524.1 Shaft protecting sleeve
524.2 Shaft protecting sleeve
524.3 Shaft protecting sleeve
524.4 Shaft protecting sleeve
524.5 Shaft protecting sleeve
525.1 Spacer sleeve
525.2 Spacer sleeve
525.3 Spacer sleeve
525.4 Spacer sleeve
711.1 Column pipe
711.2 Column pipe
840 Coupling
86--2 Coupling sleeve
891 Foundation ring
920 Nut
920.39 Impeller nut

78 SNW
Rev.4, 15.05.2002
Type Series Booklet SNW

SNW 79
Rev.4, 15.05.2002
Type Series Booklet
SNW

1481.5/4--10 15.05.2002 Oc We reserve rights to alter specifications

You might also like