EET 0142 ELECTRICAL INSTALLATION

Name:_____________________________________ Date:____________________
Student I/D No.:_____________

A two-storey bungalow houses receiving a supply source of 3-phase 415V, 50Hz, 3


phase from the supplier with expenses as follows:

Ground floor

i. 5 x 36W fluorescent light

ii. 3 x 60W filament lamp

iii. 3 x 60W currency ceiling fans

iv. 2 x 150W spotlight points (sportlight)

v. 6 points 13A output socket (radial circuits)

vi. 1 point high in the air conditioner 1.5 horsepower

vii. 1 point proportional water heater 3.3kW

viii. 1 point cookers equipped with a 5kW rated 13A output socket

ix. 1 water pump motor 415V 3-phase, 3-rated horsepower

First floor

i. 5 x 36W fluorescent lamp

ii. 3 x 60W filament lamp eye

iii. 3 x 60W currency ceiling fans

iv. 2 x 150W spotlight points (sportlight)

v. 6 points 13A output socket (radial circuits)

vi. 1 x 3.3kW heating and water

vii. 1 x 1.5hp air conditioning

Page 1 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Question 1.

According to the Third Schedule (Regulation 11) Schedule B, Electricity Regulations


1994, calculate the total maximum current and total current budget for these expenses
and determine the percent reduction in the current budget.

Question 2.

Please draw the electrical wiring on the floor plan has been prepared.

Question 3.

Based on the above details, draw a schematic diagram of a line for the installation of a
small circuit fuse service to end by pointing control devices, proportions protection
devices & size of the cables.

Page 2 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Question 1
Calculation
Type of load
Max Current Expected Current

Fluorescent Lamp

Incandescent lamp

Ceiling Fan

Floodlight Lamp

Socket outlet

H.P Air Conditioner

Water Heater

Electric cooker with SSO 13A

Motor 3 Phase

Total

% Reduce after applied Diversity Factor :

% = Max Current Expected Current x 100%


Max Current

Page 3 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Question 2

ELECTRICAL LAYOUT DRAWING

Ground Floor First Floor


Page 4 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Question 3

Schematic Diagram

Please draw the schematic diagram of the circuit of components inside of the Distribution Board
(DB) as shown in the Figure 1 above. Please indicate the cable size and the current ratings of each
component. You may use the Table 3 above as reference.

Note: Please start your schematic with Power Source (415V), Cut-out Fuse and Neutral Link, kWh
meter, Main Switch and ELCB.

Page 5 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Page 6 of 7
Copyright of German Malaysian Institute. All rights reserved.
EET 0142 ELECTRICAL INSTALLATION

Page 7 of 7
Copyright of German Malaysian Institute. All rights reserved.