Professional Documents
Culture Documents
Nomenclature
Pressure compensator control
- V A -
1 2 3 4 5 12 15 16 17
Combination control (pressure feedback method)
- V C R H X -
1 2 3 4 7 8 12 13 15 16 17
Combination control (solenoid operated method)
- V C R J X -
1 2 3 4 7 8 12 13 14 15 16 17
Dual pressure control
- V D R X -
1 2 3 4 9 10 12 14 15 16 17
Power-match control
- V SA -
1 2 3 4 6 11 12 15 16
1 Applicable fluid code (Refer to Page A-5 for the 12 Direction of rotation, when viewed from the shaft
applicable models and conditions of use) end (Refer to Page A-4 for the applicable models)
No designation: Petroleum-based hydraulic fluid R: Clockwise (rightward)
W: Water-glycol hydraulic fluid L: Counterclockwise (leftward)
F: Phosphate ester hydraulic fluid *The direction of rotation (rightward or leftward) cannot be changed.
2 Model No. 13 Control method II
V: V series piston pump H: Pressure feedback method
3 Pump capacity J: Solenoid operated method
8: 8.0 cm3/rev 14 Voltage code for the solenoid valve
15: 14.8 cm3/rev A: AC 100 V (50/60 Hz), AC 110 V (60 Hz)
23: 23.0 cm3/rev B: AC 200 V (50/60 Hz), AC 220 V (60 Hz)
38: 37.7 cm3/rev N: DC 12 V
50: 51.6 cm3/rev P: DC 24 V
70: 69.8 cm3/rev
15 Piping direction (Refer to Page A-4 for the applicable
4 Control method I (Refer to Page A-4 for the models)
applicable models) No designation: Axial port
A: Pressure compensator control X: Side port
C: Combination control
D: Dual pressure control 16 Design No. (The design No. is subject to change) *1
SA: Power-match control 20: Pump model V8, V50
95: Pump model V15, V38
5 6 Pressure adjustment range 30: Pump model V23
(See the pressure adjustment range table) <When control method I is A, CH, or SA>
35: Pump model V23
7 9 Low pressure adjustment range <When control method I is CJ or D>
(See the pressure adjustment range table) 60: Pump model V70
8 10 High pressure adjustment range
Control method III
(See the pressure adjustment range table)
17 No designation: Without remote control system
11 FC valve differential pressure RC: With remote control system
A: 0.7 MPa { 7 kgf/cm 2}
B: 1.4 MPa {14 kgf/cm 2} Note:*1 Refer to Page A-68 for information on forward/backward
C: 2.1 MPa {21 kgf/cm 2} compatibility.
Refer to Page N-2 for hydraulic unit piston packs incorporating V series piston pumps, Page N-17 for NDJ series new DAIPACKs,
Page N-22 for ND series Mini-packs, Page N-27 for ND series new DAIPACKs, and Page N-30 for the NT series SSS MARK-II.
A-8
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
Models and pressure adjustment range table
Pressure compensator control ( 4 =A)
5 Pressure adjustment range
Pressure adjustment range Without remote control system With remote control system
Code
MPa {kgf/cm2} V8 V15 V23 V38 V50 V70 V15 V23 V38 V50 V70
1 0.8 to 7 { 8 to 70}
1 1.5 to 7 {15 to 70}
2 1.5 to 14 {15 to 140}
3 1.5 to 21 {15 to 210}
3 2 to 21 {20 to 210}
3 3.5 to 21 {35 to 210}
4 1.5 to 25 {15 to 250}
4 3.5 to 25 {35 to 250}
A-9
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
Nomenclature
- V SAJS - X -
1 2 3 4 5 6 7 8
1 Applicable fluid code 6 Direction of rotation, when viewed from the shaft
No designation: Petroleum-based hydraulic fluid end (Refer to Page A-4 for the applicable models)
W: Water-glycol hydraulic fluid R: Clockwise (rightward)
2 Model No. L: Counterclockwise (leftward)
V: V series piston pump 7 Piping direction
3 Pump capacity X: Side port
23: 23.0 cm3/rev 8 Design number
38: 37.7 cm3/rev (The design number is subject to change)
50: 51.6 cm3/rev 30: Pump model V23
70: 69.8 cm3/rev 95: Pump model V38
4 Control method 20: Pump model V50
SAJS: Power-match control 60: Pump model V70
- V 15 A 1 R Y - 95
1 2 3 4 5 6 7 8
1 Applicable fluid code 5 Pressure adjustment range
No designation: Petroleum-based hydraulic fluid 1: 0.8 to 7 MPa {8 to 70 kgf/cm2}
W: Water-glycol hydraulic fluid
6 Direction of rotation, when viewed from the shaft
F: Phosphate ester hydraulic fluid
end
2 Model No.
7 R: Clockwise (rightward)
V: V series piston pump
Piping port
3 Pump capacity Y: Suction port: Flange
15: 14.8 cm3/rev Discharge port: Taper pipe threads
4 Control method 8 Design No. (The design No. is subject to change) *1
A: Pressure compensator control
Note:*1 Refer to Page A-69 for information on forward/backward
compatibility.
Specifications
Discharge rate adjustment range
Theoretical Maximum operating Permissible Mass (Control method A)
1800 min 1
Model No. discharge rate pressure rotational speed kg
L/min
cm3/rev MPa {kgf/cm2} min 1
Axial port Side port Axial port Side port
V8 8.0 7 { 70} 500 to 1800 2 to 14.4 8.9
V15 14.8 21 {210} 500 to 1800 4.5 to 26.6 7.5 to 26.6 12.8 14.5
V15 (Type Y) 14.8 7 { 70} 500 to 1800 4.5 to 26.6 13.5
Note: JR-G (T) 02 and JRP-G02 are recommended for the remote control system's relief valve.
If the vent port is blocked, the pressure compensation structure does not work and the pump operates at a fixed pressure.
Foot supports and piping flanges are not provided with the pump. Order them separately as required by referring to Pages S-2
and S-4.
A-10
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
Relationship between number of revolutions of the pressure adjusting
screw and variation of discharge pressure
The discharge pressure can be set to the desired value by turning the pressure adjusting screw of the PC valve.
Turning the adjusting screw clockwise increases the pressure.
Turning the adjusting screw counterclockwise decreases the pressure.
Discharge rate
Counterclockwise Clockwise
Pressure
PC valve
Pressure adjusting screw
Socket for hex key: 6.5 (V8, V15, V23, V38)
Spool Valve housing Spring : 8 (V50, V70)
Counterclockwise
Clockwise
(up)
V8 V15, 23, 38
4th pattern*
7 25
3rd pattern
6 21
Discharge pressure change
5 17.5
(MPa) {10 kgf/cm2}
2nd pattern
4
14
3
10.5
1st pattern
2
7
1
3.5
0
0 0.5 1 1.5 2 2.5 3 0
Pressure adjusting screw revolutions 0 1 2 3 4 5
Pressure adjusting screw revolutions
V50, 70 * The 4th pattern applies to V23 and V38.
21
3rd pattern Excessive loosening of the pressure adjusting screw may
cause oil to leak from the threaded section or parts to
Discharge pressure change
17.5
spring out. Do not loosen the screw beyond the pressure
(MPa) {10 kgf/cm2}
3.5
0
0 1 2 3 4 5
Pressure adjusting screw revolutions
A-11
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
(decrease)
(increase)
Clockwise
Counterclockwise
Clockwise
The discharge rate can be roughly judged from the protruding length of the discharge rate adjusting screw (L).
End cap
Overtightening of the discharge rate adjusting screw may cause oil
Discharge rate to leak from the threaded section. Do not tighten the screw beyond
adjusting screw
the adjustment range.
A-12
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
V8 side port V15 axial port, V15 (type Y)
16 26
15 1800 min1 1800 min1
24
14 22
13 1500 min1 1500 min1
Discharge rate (L/min)
26 40
1800 min1 1800 min1
24
36
22
1500 min1 32
20
18 28
16 1200 min1 24 1200 min1
14 1000 min 1
1000 min1
20
12
10 16
8 12
6 8
4
4
2
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
Thread length L (mm)
Thread length L (mm)
50 50
45 45
40 1200 min1 1200 min1
40
35 1000 min 1 35 1000 min1
30 30
25 25
20 20
15 15
10 10
5 5
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
Thread length L (mm) Thread length L (mm)
70 90 1200 min1
1200 min1
60 80
1000 min1 1000 min1
70
50
60
40 50
30 40
30
20
20
10 10
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Thread length L (mm) Thread length L (mm)
A-13
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
The discharge rate adjusting screws are provided with scales on the nameplates as shown below.
High quantity High quantity scale set position
Scale scale plate
Low quantity scale set position
Pump model Low quantity High quantity High quantity lock nut Low quantity scale plate
adjusting screw adjusting screw Hexagonal flat nut
: 17 (V15, V23, V38)
V15C 0 to 7 5 to 15 : 22 (V70)
V23C 0 to 9 8 to 17
V38C 0 to 9 9 to 18
V70C 0 to 9 6 to 18
High quantity adjusting screw (QH)
(Scale graduation: 1) Socket for hex key
: 5 (V15, V23, V38)
Note: The high quantity adjustment range may be restricted due to the
: 8 (V70)
setting for the low quantity range. Low quantity lock nut Low quantity adjusting screw (QL)
See the graphs on Page A-15 for details. Hexagonal flat nut
Width across flats: 26 (V15, V23, V38)
: 36 (V15, V23, V38)
: 39 (V70)
: 55 (V70)
Adjust the discharge rate according to the relevant discharge rate adjustment graph by following the procedure below.
(1) For the low quantity range, read the value for the desired discharge rate on the graph and turn the low quantity adjusting
screw to set the scale position to the read value.
(2) For the high quantity range, read the value for the desired discharge rate on the line corresponding to the value for the low
quantity range on the graph and turn the high quantity adjusting screw to set the scale position to the read value.
(3) When adjusting only the high quantity range, loosen the lock nut and adjust as described above.
(4) When adjusting only the low quantity range, loosen the lock nut on the hight quantity adjustment screw and adjust the
setting for the low quantity range as described above while holding the high quantity adjusting screw in place with a hex
key.
Example of adjustment
Example: When adjusting the discharge rate of V15C at 1500 min 1 to 7 L/min for the low quantity range (QL) and 18 L/min
for the high quantity range (QH)
From the discharge rate adjustment graph for V15C at 1500 min 1, first read the value for QL = 7 L/min, which is 4, and
adjust the low quantity adjusting screw accordingly.
Then, read the value for QH = 18 L/min on the line for 4 of QL, which is 7, and adjust the high quantity adjusting screw
accordingly.
The setting values indicated above may change slightly Discharge rate adjustment graph for V15C in combination control
depending on the conditions of use (f luid temperature, 1500 min1
hydraulic fluid type, etc.) 24
22
For final fine adjustment, repeat the adjustment described
20 7
above and achieve the setting appropriate for the actual
Low quantity scale
Discharge rate (L/min)
18 6
application. 16
5
4
14 3
Factory settings 12 2
The discharge rate for the high quantity range is 10 1
8
factory adjusted to the maximum discharge rate and 7
6
the discharge rate for the low quantity range is factory
4
adjusted as follows. 2
Pump model Low quantity (QL) setting 0
0 1 2 3 4 5 6 7
Low quantity scale ()
V15C Scale position: 3 5 6 7 8 9 10 11 12 13 14 15
High quantity scale ()
V23C Scale position: 3
V38C Scale position: 2
V70C Scale position: 1.5
A-14
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
V15C combination control (1800 min 1) V15C combination control (1500 min 1)
1800 min1 1500 min1
30 24
28 22
26
20
V23C combination control (1800 min 1) V23C combination control (1500 min 1)
1800 min1 1500 min1
45 45
Low quantity scale
9
40 8 40
35 6 35 9
5 8
30 4 30 7
3 6
5
2
25 1 25 4
3
2
20 20 1
15 15
10 10
5 5
0 0
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
Low quantity scale () Low quantity scale ()
8 9 10 11 12 13 14 15 16 17 8 9 10 11 12 13 14 15 16 17
High quantity scale () High quantity scale ()
V38C combination control (1800 min 1) V38C combination control (1500 min 1)
1800 min1 1500 min1
70 70
Low quantity scale
65 65
Low quantity scale
9
60 8 60
Discharge rate (L/min)
7
55 55 9
6
50 5 50 8
7
45 4 45 6
40 3 40 5
2 4
35 35 3
1
30 30 2
1
25 25
20 20
15 15
10 10
5 5
0 0
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9
Low quantity scale () 9 10 11 12 13 14 15 16 17 18 Low quantity scale () 9 10 11 12 13 14 15 16 17 18
High quantity scale () High quantity scale ()
V70C combination control (1800 min 1) V70C combination control (1500 min 1)
1800 min1 1500 min1
140 140
130 130
120 120
Low quantity scale
Discharge rate (L/min)
9
110 110
Discharge rate (L/min)
8
Low quantity scale
100 7 100 9
90 6 8
5
90
80 7
4 80 6
70 3 70 5
60 2
60 4
1
50 50 3
2
40 40 1
30 30
20 20
10 10
0 00
0 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
Low quantity scale () 6 7 8 9 10 11 12 13 14 15 16 17 18 Low quantity scale ()
6 7 8 9 10 11 12 13 14 15 16 17 18
High quantity scale () High quantity scale ()
A-15
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PS
Pressure 14 MPa
{ {
MPa With V8
pump
7 MPa 1 MPa
1 MPa
Time (sec.)
Discharge rate
V8 V15 V23
70 75 75
e
rat
arge
sch
1 1
65 70 70 di min
0 min um 1
1,800
Noise level (dB-A)
1,500
1
min m in ma
1,500 disc
h 1,500 At
60 um te 65 65
im ra
ax rge
m a
55 At isch At full cutoff
d 60 At full cutoff 60 At full cutoff
50 55 55
0 1 2 3 4 5 6 7 0 3.5 7 10.5 14 17.5 21 0 3 .5 7 1 0 .5 1 4 1 7 .5 2 1 2 5
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
Noise level (dB-A)
Noise level (dB-A)
m g At full cutoff
At char
dis
65 65 65
At full cutoff At full cutoff
60 60 60
55 55 55
0 3 .5 7 1 0 .5 1 4 17. 5 21 25 0 3 .5 7 1 0 .5 1 4 1 7 .5 2 1 0 3 .5 7 1 0 .5 1 4 1 7 . 5 2 1
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
A-16
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
General performance
Discharge rate setting: maximum, Fluid used: ISO VG32, Fluid temperature: 50C
1800 min1
V8 V15 V23
100 100
Shaft input
100
Volume efficienc Volume efficiency Volume efficiency
(kW)
90 y 90 90
Shaft input
Total efficiency
(kW)
80 y 80 Total efficiency 80
Total efficienc
Efficiency (%)
Efficiency (%)
Shaft input
Efficiency (%)
70 70 70
(kW)
60 60 12 60
50 50 p ut 10 50 25
a ft in
40 pu t 40 Sh 8 40 20
ft in 2 put
Sha ft in
30 1.5 30 6 30 Sha 15
20 1 20 4 20 10
10 0.5 10 2 10 5
0 0 0 0 0 0
0 1 2 3 4 5 6 7 0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21 25
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
90 90 90
Shaft input
Total efficiency
Shaft input
Total efficiency 80 80 Total efficiency
80
(kW)
(kW)
Efficiency (%)
Efficiency (%)
70 70
Efficiency (%)
70 35
60 ut 30 60 60
ft inp
50 S ha 25 50 50 50 50
40 20 40 40 40 40
ut put
30 inp 30 t in
30 15
Sh aft 30
S haf 30
20 10 20 20 20 20
10 10 10 10 10
5
0 0 0 0 0
0 0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21
0 3.5 7 10.5 14 17.5 21 25
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
1500 min1
V8 V15 V23
100 100 100
Shaft input
Shaft input
(kW)
90
(kW)
90
80 Total efficiency
80 y 80
Total efficienc
y Total efficienc
Efficiency (%)
70
Shaft input
Efficiency (%)
Efficiency (%)
70 70
(kW)
60 60 60
12 30
50 50 50
10 25
40 40 put
ut 2 f t in 8 40 20
30 ft inp Sha ft inpu
t
Sha 1.5 30 6 30
Sha 15
20 1 20 4 20 10
10 0.5 10 2 10 5
0 0 0 0 0
0 1 2 3 4 5 6 7 0
0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21 25
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
Volume efficiency
Shaft input
(kW)
90 90 90
(kW)
(kW)
70 35 70 70
Efficiency (%)
Efficiency (%)
60 30 60 60
50 25 50 50 50 50
ut
ft inp 20 40 40 40 40
40 ha
S
30 15 30 30 30 p ut 30
ut ft in
20 ft inp 20 Sha
20 10 Sha 20 20
10 5 10 10 10 10
0 0 0 0 0 0
0 3.5 7 10.5 14 17.5 21 25 0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
Note: The efficiency varies depending on the discharge rate setting. When selecting the motor capacity, refer to the shaft input
characteristics on Page A-19.
A-17
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
A-18
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
Shaft input characteristics
Common to 1800 min1 and 1500 min1 Fluid used: ISO VG32, Fluid Temperature: 50C
V8 V15 V23
2.5 15 20
nin
mi
L//m
2.0 15 L/min n . 4L minin
mini 15 41 3LL//m
LL//m
Shaft input (kW)
0 0 0
0 1 2 3 4 5 6 7 0 3.57 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21 25
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
35
35 nin 7 L
nin /mi
LL/m
4. inin
30 /mi
L/m
30
. 9 30 10 LL//mm
7 .8L inin 25 92 L/m /mi
nin
3 .7
6 L/m /m 25 8 n
25
.5L inin .4L inin /mmini
56 L/m
7
7 LL/m /m 8LL/
20 2L
/ m 20 .9 in
20 62.
45. /min
61 LL/m minin
15 46.
5 15 LL//m
15
/minin /minin 41.9
LL/m 10 31.0L
L/m 10
10 33.9 inin 20.9LL/m
/minin
5 15 .5 LL /m
/m 5
5
0 0
0
0 3.5 7 10.5 14 17.5 21 25 0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
At full cutoff
3.5 3.5
1.5 At full cutoff
At full cutoff 3.0 3.0 1st pattern
1st pattern
2.5 2.5
1.0 1st pattern
2.0 2.0 At full cutoff
At full cutoff 1.5 1.5
At full cutoff
0.5 1.0 1.0 At full volume
At full volume At full volume
0.5 0.5
0 0 0
0 3.5 7 10.5 14 17.5 21 25 0 3.5 7 10.5 14 17.5 21 0 3.5 7 10.5 14 17.5 21
Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2} Pressure (MPa) {10 kgf/cm2}
A-19
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
6
31.2
70
+0.5
66
90
43
125
50
16 0.025
63 0.46
0
0.13
18
R40
0
0
66 9
18
132 126.5
100
148
143
Suction port G
Bonded seal
Discharge port G
Bonded seal
Mass: 8.9 kg
A-20
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V15ARX-95
31.2
102
84
+0.3
20
57.0
11 0
130
66
82.55 0.050
0
Discharge port G1
11.7 21.15
0
0.15
144 O-ring boss 147 R47.5
19.05 0.025
0
170 207 105.6
Mass: 14.5 kg
V15AR-95
+0.3
84
20
11 0
57.0
130
66
Mass: 12.8 kg
V15A3RX-95RC
Discharge rate adjusting screw (clockwise: discharge rate decrease)
Socket for hex key: 5
Hexagonal flat lock nut: 17
Oil filler port on the case
94 39
Vent port RC 48 44.5 6.5
PC remote control valve PC differential pressure
34 minimum
Drain port Rc 12.7 6.0 adjusting screw
Suction port G1 (factory adjusted)
31.2
+0.3
84
11 0
20
57.0
130
66
82.55
0
0.050
A-21
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
31.2
O-ring boss
144.5
+0.3
82.5
84
11 0
20
57.0
130
66
82.55
0
0.05
11.7 0
57.2 169.5 21.15 0.15 R47.5
19.05 0.025
0
170 191 105.6
Discharge port G1
O-ring boss
Mass: 14.3 kg
33
152
103
+0.3
84
11 0
20
20
57.0
82.55 0.05
0
130
66
Discharge port G1
O-ring boss 21.15 0.15
0
Mass: 17.6 kg
48 44.5
33
12.7 6.0
177
128
98.5
+0.3
11 0
84
20
57.0
82.55 0.05
0
130
66
Discharge port G1 0
21.15 0.15
Suction port G1 O-ring boss 11.7 R47.5
144 147 19.05 0.025
0
O-ring boss
170 284 maximum 105.6
Mass: 18.4 kg
A-22
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V15CRJX-95 Low pressure adjusting screw (PL)
Socket for hex key: 6.5
Hexagonal flat lock nut: 27
Solenoid Oil filler port on the case
High pressure adjusting screw (PH)
(KSO-G02-2B--C)
Socket for hex key: 6.5
Discharge rate adjusting screw Drain port Rc
Hexagonal flat lock nut: 27
(low quantity) 281 (AC), 284 (DC)
Discharge rate adjusting screw 70 44.5 82 maximum
4.76 0.048 32
+0.003
Combination control valve
(high quantity) 48
18.0
12.7 6.0
33
152
103
+0.3
11 0
84
20
57.0
82.55 0.05
0
66
130
Discharge port G1 0
33
Discharge rate 12.7 60
adjusting screw
177
(high quantity)
128
98.5
+0.3
20
84
11 0
57.0
82.55 0.05
0
130
66
Discharge port G1 0
21.15 0.15
O-ring boss R47.5
19.05 0.025
0
144 11.7
105.6
170 147
Suction port G1 284 maximum
O-ring boss Mass: 20.1 kg
18.0
12.7 6.0
33
Discharge rate
152
adjusting screw
103
+0.3
20
11 0
84
57.0
82.55 0.05
0
130
66
0
21.15 0.15
Discharge port G1 R47.5
19.05 0.025
0
144 O-ring boss 11.7
105.6
170 147
Suction port G1 207
O-ring boss Mass: 17.8 kg
A-23
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
48 44.5
Discharge rate
18.0
adjusting screw
33
(clockwise: discharge 12.7 6.0
rate decrease)
177
Socket for hex key: 5
Hexagonal flat lock nut: 17
128
98.5
+0.3
11 0
84
20
57.0
82.55 0.05
0
130
66
Discharge port G1 21.15
0
0.15
O-ring boss R47.5
19.05 0.025
0
144 11.7
105.6
170 147
Suction port G1 207 Mass: 18.6 kg
O-ring boss
V15SARX-95
+0.3
11 0
84
20
57.0
130
66
82.55
0
0.050
Discharge port G1 11.7
144 O-ring boss 21.15 0.15
0
R47.5
170 147
19.05 0.025
0
207 105.6
Mass: 15.2 kg
V15SA R-95
+0.3
82.5
11 0
84
20
57.0
130
66
82.55
0
0.050
57.2 11.7 0
R47.5
169.5 21.15 0.15
170 191 19.05 0.025
0
105.6
Discharge port G1
O-ring boss Mass: 13.5 kg
A-24
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V15A1RY-95
31.2
Socket for hex key: 6.5
Discharge rate adjusting screw (plugged) 48 Hexagonal flat lock nut: 27
(clockwise: discharge rate decrease) 18.0
Socket for hex key: 5 PC valve
12.7 6.0
Hexagonal flat lock nut: 17
4.76 0.048 32
+0.003
Suction port 18
+0.3
11.0 0
98
84
20
57.0
82.55 0.05
0
400.2
130
66
4-M10, depth 20 Discharge port A 0
21.15 0.15 R47.5
Prepared hole depth 25 Rc (plugged)
19.05 0.025
0
20 40 11.7
105.6
400.2 72 148
170 191
169
Discharge port B
Rc (plugged)
Mass: 13.5 kg
* Use SHA15 or SSA20 pipe flange (JIS B 2291) or equivalent at the suction side.
A-25
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
31.2
110
+0.3
93
0
25
13.5
61
101.6 0.05
0
1 7 2
67
Discharge port G1
0
146 O-ring boss 11.2 25.08 0.23 R60
22.2
+0.025
184 0 146
170
227
Mass: 21.5 kg
V23AR-30
184
Drain port Rc
43 Pressure adjusting screw
6.3 35
+0.025
52 minimum 58.5 0
27 (clockwise: pressure increase)
PC valve Discharge rate adjusting screw 51 Socket for hex key: 6.5
(clockwise: discharge rate decrease) 6.5 Hexagonal flat lock nut: 27
Suction port G1 Socket for hex key: 5 12.7 9
Oil filler port on the case
31.2
+0.3
91.5
93
25
13.5
61
101.6 0.05
0
1 7 2
67
0
66.6 Discharge port G1 11.2 25.08 0.23 R60
140 O-ring boss 189 22.2
+0.025
0 146
211
Mass: 18.4 kg
V23A4RX-30RC
39
Vent port RC 114
27
Discharge rate adjusting screw Drain port Rc PC differential pressure
PC remote 6.5
6.3 35
+0.025
(clockwise: discharge rate decrease) 52 minimum 58.5 0 adjusting screw
control valve
Socket for hex key: 5 (factory adjusted)
51
Hexagonal flat lock nut: 17
31.2
12.7 9
Suction port G1
Oil filler port on the case
O-ring boss
173.5
111.5
+0.3
0
93
25
13.5
61
101.6 0.05
0
1 7 2
67
Discharge port G1
0
146 O-ring boss 11.2 25.08 0.23 R60
22.2
+0.025
184 0 146
170
227 Mass: 23 kg
A-26
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V23A4R-30RC
184
114
43
Drain port Rc 27
Vent port RC 52 minimum 58.5 PC differential pressure
6.3 35
+0.025
PC remote control valve 0 6.5 adjusting screw
Discharge rate adjusting screw 51
(factory adjusted)
(clockwise: discharge rate decrease) 12.7 9
Suction port G1 Oil filler port on the case
31.2
Socket for hex key: 5
O-ring boss Hexagonal flat lock nut: 17
155.5
+0.3
0
93.5
93
13.5
25
61
101.6 0.05
0
172
67
0
66.6 Discharge port G1 11.2 25.08 0.23 R60
22.2 0
+0.025
O-ring boss 189 146
140
211
Mass: 20 kg
V23CRHX-30
Low pressure adjusting screw (PL)
Socket for hex key: 6.5
Suction port G1 Hexagonal flat lock nut: 27
O-ring boss Drain port Rc High pressure adjusting screw (PH)
Combination control valve Socket for hex key: 6.5
213 58.5 Hexagonal flat lock nut: 27
Discharge rate 82 maximum
51 Oil filler port on the case
adjusting screw
(low quantity) 12.7 9
Discharge rate
33
6.3 35
+0.025
adjusting screw 0
(high quantity)
160
+0.3
0
111
13.5
93
25
61
67
172
Discharge port G1
101.6 0.05
0
O-ring boss 11.2 R60
146
0 146
170 25.08 0.23
184
303 maximum 22.2
+0.025
0
Mass: 23.4 kg
Discharge rate
6.3 35
+0.025
0
adjusting screw
(high quantity)
185
136
+0.3
0
106.5
13.5
93
25
61
67
172
Discharge port G1
146 O-ring boss 101.6 0.05
0
R60
11.2
0 146
184 170 25.08 0.23
22.2
+0.025
303 maximum 0
Mass: 24.2 kg
A-27
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
33
+0.025
0
adjusting screw
(high quantity)
160
+0.3
0
111
13.5
93
25
61
67
172
Discharge port G1
O-ring boss 101.6 0.05
0
R60
146 11.2
170 0 146
184 25.08 0.23
V23C4RJX-35RC
33
adjusting screw
6.3 35
+0.025
(high quantity) 0
185
+0.3
136
13.5 0
106.5
93
25
61
172 67
Discharge port G1
101.6 0.05
0
146 O-ring boss 11.2 R60
170 0 146
184 25.08 0.23
Mass: 25.9 kg
V23DRX-35
Solenoid KSO-G02-2B-C
Low pressure adjusting screw (PL)
Suction port G1 Socket for hex key: 6.5
O-ring boss Dual pressure control valve Hexagonal flat lock nut: 27
(31.2)
301.5 (AC), 304.5 (DC) 58.5 High pressure adjusting screw (PH)
Drain port Socket for hex key: 6.5
68 61 Rc Hexagonal flat lock nut: 27
51
17 Oil filler port on the case 82 maximum
12.7
9
6.3 35
+0.025
33
0
160
+0.3
13.5 0
111
93
25
61
Discharge port G1
172
67
O-ring boss
101.6 0.05
146
+0.025
11.2
0
0
0
Mass: 24.8 kg
A-28
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V23D4RX-35RC Low pressure adjusting screw (PL)
Solenoid KSO-G02-2B--C Socket for hex key: 6.5
Hexagonal flat lock nut: 27
(31.2)
Dual pressure control valve High-pressure PC differential
Vent port RC pressure adjusting screw (PH)
301.5 (AC), 304.5 (DC) 58.5 (factory adjusted)
177.5
Drain port Rc
68 61 51 82 maximum
56 Oil filler port on the case
17
12.7
33
9
6.3 35
+0.025
0
Suction port G1
185
O-ring boss
136
+0.3
106.5
13.5 0
93
25
61
101.6 0.05
0
172
Discharge rate
67
adjusting screw
+0.025
25.08 0.23
11.2
0
22.2 0
146 R60
184 170
146
Discharge port G1 227
O-ring boss
Mass: 25.6 kg
+0.3
0
93
25
13.5
61
101.6 0.05
0
172
Discharge port G1 67
0
146 O-ring boss 11.2 25.08 0.23 R60
22.2
+0.025
184 170 0 146
227 Mass: 22.2 kg
V23SAR-30
Load pressure port 184
7
-20UNF-2B 114
16
43 Differential pressure setting
O-ring boss Drain port Rc adjusting screw (FC valve)
(with UNF-Rc (male) 27 Socket for hex key: 6.5
Power-match 52 minimum 58.5
control valve conversion nipple) 6.3
+0.025
0 35 Hexagonal flat lock nut: 27
51 6.5 Maximum pressure
Discharge rate adjusting screw adjusting screw (PC valve)
(clockwise: discharge rate decrease) 12.7 9
Socket for hex key: 6.5
Suction port G1
31.2
+0.3
13.5 0
93.5
93
25
61
0.05
0
101.6
172
67
0
66.6 Discharge port G1 11.2 25.08 0.23 R60
189 22.2
+0.025
140 O-ring boss 0 146
211
Mass: 19.1 kg
A-29
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
46
12.7 9
185
162
122
+0.3
13.5 0
93
25
71.5
61
101.6 0.05
0
172
67
146 Discharge port G1 11.2 25.08 0.23
0
R60
O-ring boss
22.2 0
+0.025
180 146
170
Suction port G1
227
O-ring boss
Mass: 25 kg
A-30
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V38ARX-95
31.2
6.3 35
+0.025
Hexagonal flat lock nut: 17 0
25
+0.3
13.5 0
121
110
73
101.6 0.05
0
172
79
Discharge port G1
0
O-ring boss 25.08 0.23
R60
11.2 22.2 0
+0.025
Mass: 26 kg
V38AR-95
+0.3
13.5 0
110
97.5
73
101.6 0.05
0
172
79
Discharge port G1 0
O-ring boss 25.08 0.23
11.2 22.2 0
+0.025 R60
66.6 202 146
196 222
Mass: 24.4 kg
V38A4RX-95RC
Discharge rate adjusting screw
Vent port RC (clockwise: discharge rate decrease)
(with UNF-Rc (male) 120 58.5 39
Socket for hex key: 5
conversion nipple) 58 minimum 6.5
Hexagonal flat lock nut: 17
PC remote control valve 51 PC differential pressure
6.3 35
+0.025
0
adjusting screw
Drain port Rc 12.7
(factory adjusted)
31.2
+0.3
122.5
110
13.5 0
73
172
79
Mass: 28.7 kg
A-31
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
31.2
O-ring boss on the case
161.5
25
+0.3
110
13.5 0
99.5
73
172
79
Discharge port G1
101.6 0.05
0
O-ring boss 11.2 R60
0
66.6 202 25.08 0.23
146
22.2
+0.025
196 222 0
Mass: 26 kg
31.2
Hexagonal flat lock nut: 27
Combination control valve High pressure adjusting screw (PH)
219 58.5 Socket for hex key: 6.5
Suction port G1 Discharge rate Hexagonal flat lock nut: 27
adjusting screw 51 82 maximum
O-ring boss Drain port Rc
(low quantity) 12.7 6.3 0 35
+0.025
Discharge rate 9
adjusting screw
33
(high quantity)
171
25
+0.3
122
13.5 0
110
73
172
79
Discharge port G1
101.6 0.05
0
6.3 35
+0.025
(high quantity) 0
196
25
147
117.5
+0.3
13.5 0
110
73
172
79
Discharge port G1
101.6 0.05
0
A-32
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V38CRJX-95 Low pressure adjusting screw (PL)
Socket for hex key: 6.5
88 61 Hexagonal flat lock nut: 27
31.2
Combination control valve High pressure adjusting screw (PH)
Socket for hex key: 6.5
Suction port G1 Solenoid Hexagonal flat lock nut: 27
O-ring boss (KSO-G02-2B--C) 307 (AC), 310 (DC) 58.5
Discharge rate 51 Oil filler port on the case
Drain port Rc
adjusting screw 12.7 82 maximum
(low quantity) 9
Discharge rate 6.3 35
33
+0.025
0
adjusting screw
(high quantity)
171
25
+0.3
122
13.5 0
110
73
172
79
Discharge port G1 101.6 0.05
0
33
Discharge rate
adjusting screw
(high quantity)
196
6.3 35
+0.025
0
147
25
+0.3
13.5 0
117.5
110
73
172
79
Discharge port G1
101.6 0.05
0
O-ring boss
11.2 0 R60
172 25.08 0.23
179
196 22.2
+0.025
0
146
309 maximum
Mass: 31.5 kg
Dual pressure
High pressure adjusting screw (PH)
control valve
Socket for hex key: 6.5
Suction port G1 Hexagonal flat lock nut: 27
O-ring boss Solenoid 307 (AC), 310 (DC) 58.5
(KSO-G02-2B-C) Drain port Rc 51
Oil filler port on the case 82 maximum
12.7
9
6.3 35
+0.025
0
33
171
25
+0.3
122
13.5 0
110
73
Discharge rate
adjusting screw
(clockwise: discharge
172
79
rate decrease)
Socket for hex key: 5
Hexagonal flat lock nut: 17
101.6 0.05
0
R60
11.2 0
31.2
(KSO-G02-2B--C)
Suction port G1 Drain port Rc Hexagonal flat lock nut: 27
Dual pressure
O-ring boss control valve High-pressure PC differential
pressure adjusting screw (PH)
88 61 307 (AC), 310 (DC)
(factory adjusted)
56 183.5 58.5 56 82 maximum
51 Oil filler port
12.7 on the case
33
9.0
6.3 35
+0.025
0
196
147
+0.3
25
117.5
110
13.5
73
Discharge rate
adjusting screw
(clockwise: discharge
rate decrease) 172
79
Socket for hex key: 5
Hexagonal flat lock nut: 17
101.6 0.05
0
R60
11.2 0
172 25.08 0.23 146
179
Discharge port G1
22.2
+0.025
Mass: 31.3 kg
0
196 O-ring boss 233
V38SARX-95
Drain port Rc
Differential pressure setting
Load pressure port adjusting screw (FC valve)
7
16 -20UNF-2B O-ring boss 120 58.5 39 Socket for hex key: 6.5
(with UNF-Rc (male) conversion nipple) Hexagonal flat lock nut: 27
58 minimum 6.5
Maximum pressure
31.2
Power-match control valve 51 6.3
+0.025
0 35 adjusting screw (PC valve)
Discharge rate adjusting screw
12.7 Socket for hex key: 6.5
(clockwise: discharge rate decrease)
Suction port G1 9 Hexagonal flat lock nut: 27
Socket for hex key: 5
O-ring boss Hexagonal flat lock nut: 17
33
122.5
+0.3
0
110
13.5
73
172
79
101.6 0.05
0
Discharge port G1 R60
11.2
O-ring boss 25.08 0.23
0
V38SAR-95
Differential pressure setting
adjusting screw (FC valve)
Load pressure port
Socket for hex key: 6.5
16 -20UNF-2B O-ring boss
7
+0.3
25
0
13.5
99.5
110
73.0
172
79
Discharge port G1
101.6 0.05
0
Mass: 25.1 kg
A-34
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V38SAJS-RX-95
8.5 26.5
FC differential pressure adjusting screw
Socket for hex key: 6.5
Hexagonal flat lock nut: 27
245 PC differential pressure adjusting screw
(factory adjusted)
JRP drain port Rc
51 58.5
9
195.5
179
173
25
+0.3
133
0
13.5
72.5
101.6 0.05
73
Discharge rate
172
79
adjusting screw
0
Discharge port G1 25.08 0.23
O-ring boss 11.2 R60
172 22.2
+0.025
0
146
196 179
233
Mass: 32 kg
A-35
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
Discharge port
37
+0.015 38
7.94 +0.030
1 split flange boss
156
129
(SAE J518)
124
32
126.95
127.00
75
18
8
69.9
104
95
161.9
150.4
32
M12P1.75 35.35
0
0.2
210 35.7 18.5 181
Effective thread depth 20
31.75 0.05
0
(at 4 positions on both sides) 70 252
Suction port 247.5
1 split flange boss 291 40
(SAE J518) (both sides)
Mass: 50 kg
V50A3RX-20RC
Vent port
7
-20UNF-2B O-ring boss
16
7.94 +0.030
+0.015 38
1 split flange boss
156
124
129
(SAE J518)
32
127.00
126.95
75
18
8
69.9
104
95
161.9
M12P1.75
Effective thread depth 20 0 150.4
32
35.35 0.2
181
210 (at 4 positions on both sides) 35.7 18.5
31.75 0.05
0
252
Suction port 70
1 split flange boss 247.5
(SAE J518) 291 40
(both sides)
Mass: 52.1 kg
V50SARX-20
Differential pressure setting
adjusting screw (FC valve)
Load pressure port Socket for hex key: 6.5
7
16 -20UNF-2B O-ring boss Hexagonal flat lock nut: 27
(with UNF-Rc (male) conversion nipple) Maximum pressure
Discharge rate adjusting screw adjusting screw (PC valve) 68
(clockwise: discharge rate decrease) 310 57 Socket for hex key: 6.5
Hexagonal flat lock nut: 27 8
Socket for hex key: 6 174
Hexagonal flat lock nut: 19 Drain port Rc 32
93 minimum
Power-match 45 1
control valve 70 10 Oil filler port on the case /2
39
Discharge port
37
7.94 +0.030
+0.015 38
202
(SAE J518)
124
32
127.00
75
18
126.95
8
69.9
104
95
M12P1.75 161.9
Effective thread depth 20 150.4
32
0
35.35 0.2
181
210 (at 4 positions on both sides) 35.7 18.5
31.75 0.05
0
A-36
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V50SAJS-RX-20
8
35.7
(9.4)
PC differential pressure adjusting screw
40 (factory adjusted)
69.9
FC differential pressure adjusting screw
M12P1.75 Socket for hex key: 8
Effective thread depth 20 Hexagonal flat lock nut: 32
Flange dimensions View B-B
(at two positions)
Drain port Rc
Surge absorbing valve Electromagnetic proportional pressure valve wiring port
vent port Rc Safety valve
JRP-G02--23
332 57
Load pressure port Rc JR drain port RC
242 167
Oil filler port on the case
70 10 1/2
45
7.94 +0.030
+0.015 38
B
205
120
32
75
127.00
126.95
8
(18)
104
93
161.9
32
Mass: 69 kg
A-37
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
166
7.94 +0.03
+0.015 38
flange boss
134
119
(SAE J518)
83
18
127.00
126.95
69.9
102
0
161.9
M12 P1.75 35.35 0.2
150.4
32
31.75 0.05
0
Effective thread 181
208 depth 20 18.5 260.5
35.7
Suction port 73
1 split flange boss 256.5
(SAE J518) 40
300 (both sides)
Mass: 55 kg
V70A3RX-60RC
Vent port
7
-20UNF-2B O-ring boss
16
74
(with UNF-Rc (male) conversion nipple) Drain port Rc 32
Discharge rate adjusting screw 320 57 Oil filler port on the case
(clockwise: discharge rate decrease) 10 8
183
Socket for hex key: 6 PC differential pressure
PC remote 102 minimum
Hexagonal flat lock nut: 19 adjusting screw
control valve 73 451/2
(factory adjusted)
7.94 +0.03
+0.015 38
192.5
166
134
119
18
83
127.00
126.95
69.9
102
M12 P1.75
Effective thread depth 20 0 161.9
35.35 0.2
150.4
32
31.75 0.05
0
181
208 Discharge port 18.5 260.5
Suction port 1 split flange boss 35.7
(SAE J518) 73
1 split flange boss 256.5 40
(SAE J518) (both sides)
300
Mass: 57 kg
V70CRHX-60
Low pressure adjusting screw (PL)
Socket for hex key: 8 82
Drain port Rc
Hexagonal flat lock nut: 32
Combination Discharge rate 418 maximum 8 Oil filler port
High pressure
control valve adjusting screw 57 adjusting screw (PH) on the case
(low quantity) Socket for hex key: 8
73 10
Discharge rate
Hexagonal flat lock nut: 32 45
1/2 150.4
adjusting screw
(high quantity) 7.94 +0.030
+0.015 38
204
134
83
18
32
69.9
100
102
Discharge port
1 split
31.75 0.05
35.35 0.2
127.00
126.95
0
flange boss
0
A-38
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
External dimension diagram
V70SARX-60
Differential pressure setting
adjusting screw (FC valve)
Load pressure port
7 Socket for hex key: 8 74
16 -20UNF-2B O-ring boss
Hexagonal flat lock nut: 32
(with UNF-Rc (male) conversion nipple) 32
Maximum pressure
Discharge rate adjusting screw 320 57 adjusting screw (PC valve)
(clockwise: discharge rate decrease) 8
183 10 Socket for hex key: 8
Socket for hex key: 6 Hexagonal flat lock nut: 32
Hexagonal flat lock nut: 19 102 minimum
Drain port Rc
Power-match control valve 73 45 1
Oil filler port on the case /2
39
7.94 +0.03
+0.015 38
192.5
166
134
119
83
18
127.00
126.95
69.9
102
M12 P1.75 0 161.9
Effective thread 35.35 0.2
150.4
32
40 31.75 0.05
0
depth 20 181
(both sides)
18.5 260.5
208 35.7
Discharge port 73
Suction port 1 split
1 split flange boss 256.5
flange boss
(SAE J518) (SAE J518) 300
Mass: 58.5 kg
V70SAJS-RX-60
35.7
Electromagnetic proportional
40 pressure valve wiring port
69.9
Surge absorbing F B
134
valve port P
32
83
Rc
127.00
126.95
(18)
100
102
161.9
32
A-39
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
48 47 46 45 44 43 42 41 40 33
34
35
36
49
Section A-A
38 Detail of PC valve assembly Detail of trunnion
19 18 17 16 15 14 13 12 11 7
8
38 6
39
37
4 3 2 1
A A
10 9
20 22 23 24 25 26 27 28 29 30 31 32
21
A-40
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
PISTON PUMPS
Sectional structural diagram
V23, V38
47 46 45 44 43 42 41 40 39 31
32
33
34
48
Section A-A
Detail of trunnion
36 19 18 17 16 15 14 13 12 11 7
8
37 6
38
4 3 2 1
35
A A
10
20 22 23 24 25 26 27 28 29 30
21
A-41
Contact Details Internet
Before using the product, please check the http://www.daikinpmc.com/en/
guide pages at the front of this catalog. For latest information, PDF catalogs and operation manuals
59 60 61 62 63 64 65 66 67
68
45 44 43 42 41 39
Section A-A
Detail of trunnion
70 71 18
35 53 46
23 22 21 20 19 17 16 15 14 13 12 11 49 10 9 8 6 7 3 2 1
24
A A
55 5 56
25 26 27 28 29 30 31 48 32 33 34 37 38
A-42