Lampertz
Product catalogue 2009
The Company

Lampertz rst choice for your business security.


As individual as you are.
For over 75 years, Lampertz has been your partner for tailor-made business We work towards a safer future and cooperate with you to set the heading
security solutions. Its outstanding competence in the construction of data cen- for positive developments. Considering challenges as opportunities and
tres makes Lampertz rst choice for modular scaleable and individual security employing pioneering technologies protecting resources these are the
solutions for data centres of all sizes. benchmarks we want to be measured by.

Lampertz plans and realises modular data centres for any kind of demand The safe and secure progress towards a clear promising future is documen-
using the E4 formula. This formula uniquely combines optimum efciency ted by the Lampertz product catalogue for 2009: the useful combination of
in the four areas of energy, security, availability and synergy. From analysis world success and innovations has set the pace and will continue to do so
and planning through construction to turn-key handover with subsequent in the future.
optimum after-sales service, Lampertz and its comprehensive expertise is the
partner for professional support. Quality you can always depend on. Lampertz: security at its best!

Certificate
SQS herewith certies that the company named below has a management system which meets the
requirements of the normative bases specied below.

LAMPERTZ GmbH & Co. KG


DE-56472 Hof &(57,),&$7( ,41HWDQG646
KHUHE\FHUWLI\WKDWWKHRUJDQL]DWLRQ
Certied area

Whole Company )5,('+(/0/2+*5283


(see Appendix) /$03(57=*PE+ &R.*
'(+RI
Field of activity
&HUWLHGDUHD

Manufacturing and sale of :KROH&RPSDQ\


VHH$SSHQGL[
data safety and asset protection systems
as well as ofce equipment )LHOGRIDFWLYLW\
0DQXIDFWXULQJDQGVDOHRIGDWDVDIHW\DQG
Normative bases DVVHWSURWHFWLRQV\VWHPVDVZHOODVRIFHHTXLSPHQW
KDVLPSOHPHQWHGDQGPDLQWDLQVD
ISO 9001:2000 Quality Management System
0DQDJHPHQW6\VWHP
ISO 14001:2004 Environmental Management System ZKLFKIXOOOVWKHUHTXLUHPHQWVRIWKHIROORZLQJVWDQGDUGV

OHSAS Occupational Health and ,62,622+6$6


18001:1999 Safety Management System 6FRSH1R
,VVXHGRQ
9DOLGLW\GDWH
5HJLVWUDWLRQ1XPEHU&+
Swiss Association for Quality and This SQS Certicate is valid up to
Management Systems SQS and including January 26, 2010
Bernstrasse 103, CH-3052 Zollikofen Scope number 19
Issue date: November 20, 2007 Registration number 33399
Ren Wasmer Theodor Zahner
President of IQNet Managing Director SQS
,41HW3DUWQHUV 
$(1256SDLQ$)$4$)125)UDQFH$,%9LQoRWWH,QWHUQDWLRQDO%HOJLXP$1&(0H[LFR$3&(53RUWXJDO&,64,WDO\&4&&KLQD
&40&KLQD&46&]HFK5HSXEOLF&UR&HUW&URDWLD'46*HUPDQ\'6'HQPDUN(/27*UHHFH)&$9%UD]LO
X. Edelmann, President SQS T. Zahner, Managing Director SQS )21'21250$9HQH]XHOD+.4$$+RQJ.RQJ&KLQD,&217(&&RORPELD,01&0H[LFR,QVSHFWD&HUWLFDWLRQ)LQODQG
,5$0$UJHQWLQD-4$-DSDQ.)4.RUHD06=7+XQJDU\1HPNR$61RUZD\16$,,UHODQG3&%&3RODQG40,&DQDGD
4XDOLW\$XVWULD$XVWULD555XVVLD6$,*OREDO$XVWUDOLD6,,,VUDHO6,46ORYHQLD6,5,04$6,QWHUQDWLRQDO0DOD\VLD
6466ZLW]HUODQG65$&5RPDQLD7(676W3HWHUVEXUJ5XVVLD<8466HUELD
,41HWLVUHSUHVHQWHGLQWKH86$E\$)$4$)125$,%9LQoRWWH,QWHUQDWLRQDO&,64'4616$,,QF40,DQG6$,*OREDO
SCESm 002, 023 Swiss Made
7KHOLVWRI,41HWSDUWQHUVLVYDOLGDWWKHWLPHRILVVXHRIWKLVFHUWLFDWH8SGDWHGLQIRUPDWLRQLVDYDLODEOHXQGHUZZZLTQHWFHUWLFDWLRQFRP

2 Lampertz
Content

Content Risk Protector security rooms 8


Our compentece 10
System tested security rooms 14

IT-Security Rooms
ECBS certied 16
Lampertz security room LSR 18.6 E 18
Lampertz Efciency Rooms 20
Lampertz Outdoor Data Centre 22

Modular Mini Data Centre 24


Lampertz Total Benet of Usership 26
Security Safes overview 28

IT-Security Safes
Mini Data Centre - LMS 9.3 32
Air-conditioning Lampertz LMS 9.3 36
LMS 9.3 Solution Packages 38
The micro data centre - LBS 9.1 C 40

Infrastructure Solutions 42
RimatriX5 44

Infrastructure Solutions
Tier-classication for data centre infrastructure 53
Air-conditioning Systems 54
Power Supply Concepts 62
Early Fire Detection system 70
Network cabinets and equipment 76
Secure network design in IT rooms 80
Raised-oor Systems 84
Video Surveillance Solutions 86
Monitoring 90

Lampertz Media Safes 92


Media Safe Classic Line 96
Media Safe Business Line 98
Interior equipment 110

Media Safe
Lock variants 111

114

Solutions for preventative structural


re protection 112

Functional Safeguard
Wall-mounted current distributor 114
Free-standing current distributor 115
Modular door and dividing wall system 116
Fire-protection cable ducts 117

SPECTRO-DATA Vision 118


The system modules for workstation visions 120
SPECTRO-DATA Vision

Multi-functional IT-workstations 122


Control and monitoring consoles 124
Control console 126
Advantages 128
Ergonomics require economical solutions 129
Perfect cable management 131
Accessories 132
Working environment design services 135

The Friedhelm Loh Group 136


LITCOS - Security Analysis 138
Loh Finance - Financing 140
Services

Terms and Conditions 143

Lampertz 3
Lampertz IT-Security

Single source security solutions

RISK PROTECTOR RISK PROTECTOR


Lampertz Security Room LSR 18.6 E Lampertz Efciency Room-Extend
ECBS certied high-availability protection Extended basic protection for IT and
for IT-systems and network components. communications systems and their
infrastructure.

RACK PROTECTOR
Lampertz Modular Safe LMS 9.3
Physical hardware protection for racks
at the highest security level.

RACK PROTECTOR
Lampertz Basic Safe LBS 9.1 C
Physical hardware protection for IT-
components. Allowed for installation
in emergency exit and escape routes.

Lampertz Media Safes


You should never leave your data
security to chance. Use the well-proven
Lampertz safe for your documents and
data.

Lampertz SPECTRO-DATA Vision Lampertz Functional Safeguard


The multi-functional furnishing system, Solution concepts for structural
used to create exible standard and protection against re. Functional
technological workplaces. safeguard and protection against re
and corrosive smoke gases.

4 Lampertz
Lampertz IT-Security

IT-Security Rooms
RISK PROTECTOR RISK PROTECTOR
Lampertz Efciency Room-Basic Lampertz Outdoor Data Centre
The basic protection solution according Developed with physical IT security
to the FSIT for IT, engineering rooms in mind especially for mobile or tem-
and archives, and for important supply porary IT-system deployment
modules.

Lampertz infrastructure solutions


Reliably protect your IT systems against
worst case scenarios with coordinated
modular components.

Energy-efcient
climatisation solutions
Modular climatisation concepts depen-
ding on requirements and application
area. All solutions offer a high degree of
flexibility and are individually customized.

Specied network cabinets with ade-


quate accessories create a rack-based
infrastructure for your IT.

Lampertz Service Analysis, planning and management


Scaleable service packages guarantee From planning through consultations
rst-class escalation management. on energy-efficiency up to a general
contractorship - everything from a
single source.

Lampertz 5
Lampertz IT-Security

Certied environmental awareness for a clean future


It goes without saying that Lampertz has accepted its responsibility for the metals nor organic components and which do not create any environmental
ecology. And that it has done so through all its production processes. A fact hazards. In its steel working, Lampertz only uses phosphate-free degreasing
that has been documented, reviewed and conrmed annually with the ISO agents and has thus been able to reduce its consumption of energy and
14001 environmental certicate since the year 2000. water. And wherever possible plastics are avoided and substituted with
steel, which is long-lived and may be easily recycled.
For instance, Lampertz only uses harmless insulation materials in the ma-
nufacture of its security rooms and safes. In production, the company also When building data centres, Lampertz is very careful to choose the most
employs nano-ceramic conversion coatings that contain neither toxic heavy energy-efcient systems that are available on the market. This goes for

6 Lampertz
Lampertz IT-Security

all components employed, e.g. for air-conditioning and power supplies. able fuels as bio diesel and vegetable oil to operate these special emergency
Intelligent air distribution and the targeted use of rack-based water cooling power units.
systems help achieve the highest degrees of efciency and thus reduce en-

IT-Security Rooms
ergy losses. Its many years of experience in the construction of data centres Rittal - Complete IT Competence - the joint power of Rittal, Lampertz
mean that Lampertz possesses the competence to employ such innovative and Litcos is always at hand when you need to safeguard your investments,
methods as combined heat and power plants and fuel cells as mains backup achieve your targets and protect the environment.
systems. Lampertz is also able to offer its customers the use of such renew- Because: Lampertz is security at its best!

Environment-friendly paint system

Robotised bending press

By taking back old products and sending them to recycling, valu-


able raw materials are reclaimed and hazardous wastes disposed
of properly.

Lampertz 7
Lampertz IT-Security

Certied security made in Germany


Lampertz security rooms offer tailor-made protection to IT structures and of all sizes with subsequent services all over the world. The experience of
other business security applications. They deliver comprehensive security exibility only becomes possible with the convincing modular design of
against such physical hazards as re, water, smoke, unauthorised access, Lampertz security rooms. Irrespective of whether upgrades, downgrades or
electromagnetic radiation, explosions and debris loads. As an across-the- complete relocation are needed Lampertz security rooms can always be
board builder of data centres with decades of experience, Lampertz is precisely adapted to suit customer requirements.
always the rst address for the planning and construction of data centres

8 Lampertz
Lampertz IT-Security

Even under the most difcult of spatial conditions, the companys specialists Also, once construction or conversion has been completed, customers
are always able to nd a scaleable solution suited to the respective security remain in the best of hands because the customer services department
needs. And because customers need to feel good about their data centres, provides round-the-clock help and support on 365 days a year.

IT-Security Rooms
Lampertz also manufactures all the components in Germany using environ- Lampertz security at its best with quality made in Germany!
mentally-friendly and resource-saving production processes in Germany and
will take the rooms and safes back for recycling in case necessary.

From basic protection in accordance with BSI through extended


basic protection to ECBS-certied highly available systems
Lampertz is able to design any kind of security room along
with all the required data centre components, e.g. racks, UPS,
air-conditioning, power supply, re security, etc. individually and
made to measure.

Lampertz 9
Lampertz IT-Security

OUR COMPETENCE

Analysis,
A l i planning
l i and
d managementt Precision air-conditioning P
Power l system
supply t

Data centre equipment Security Monitoring

GLO

10 Lampertz
Lampertz IT-Security

IT-Security Rooms
Surveillance control centre Installation
I t ll ti double
d bl oor
Data centre cabling

Emergency power system Video surveillance Physical hardware protection

BAL CONCEPT FOR DATA CENTRES

Lampertz 11
IT-Security Rooms

Risk Protector IT-Security Rooms


safeguarding the availability of your IT-Systems
Continual information about the key economic data of current business: a
matter of course in a thoroughly organised company. But do you know where
your IT systems weak points lie? Do you know what risks you are being
exposed to? The continual availability of all data and the permanent ability to
process them is of crucial importance for your company.

Economically scaleable solutions from Lampertz

Scaleable solutions with regard to the companys tolerable IT-downtime

Explanation of symbols on the following pages: Standard protection against...

Fire Fire extingu- Corrosive Power Failure Heat Vandalism Unauthorized Electromagn. Dust Explosion Debris Theft/burglary Mechanical Bulletproof
ishing water gases Development access elds access quality

12 Lampertz
IT-Security Rooms

IT-security rooms by Lampertz


from basic protection to high-availability
We are future-oriented in our work, for our IT Security Room solu- Our IT-Security Rooms

IT-Security Rooms
tions full future standards and regulations, even today. Can be modularly extended and retted.
Our complete protection solutions provide protection against elementary Can be congurated to individual or local requirements.
threat potential from the physical environment. Lampertz offers security Can be selected in different quality classes to suit individual require-
room solutions which have scaleable system protection: from basic BSI-level ments the only IT data centre which is independent of the building it is
protection to ECBS certied, high-availability protection against re, corro- located in, a centre which you can rent or lease.
sive gases, water, dust, debris, explosions and unauthorised access. From a standard ex-warehouse solution to a tailor-made solution
available in any size.
We implement modular infrastructure solutions and data centres Investment security for the future is provided by the option to
all from a single source, from the planning stage to turnkey disassemble the modular security rooms from Lampertz and
installation. reassemble them at a different location.

Lampertz Security Room LSR 18.6 E Lampertz Efciency Room - LER Extend
Modular ECBS certied security room. High-availability protection for IT Increased level of basic protection for IT and communications systems, as
system locations and archiving systems. Always offers a high level of IT- well as for important supply modules (e.g., air-conditioning and re extingu-
security for hardware systems and network components. ishing systems). Offers higher quality protection classes for IT-systems.

Lampertz Efciency Room - LER Basic Lampertz outdoor data centre


Basic protection for IT and communications systems, as well as basic pro- The outdoor data centre is ready for use on site - worldwide - within a very
tection for important supply modules (e.g., air-conditioning and re extingu- short time.
ishing systems). Offers an appropriate level of security for IT-infrastructures.

Lampertz 13
System test

Forget simple component tests -


only system tested room constructions make your data centre secure! 1

Criterion Standard Conventional LSR LER LER


construction2 18.6 E Basic Extend

System test Test as a complete system or construction according to the following standards X   
Fire protection ECBS certication according to EN 1047-2, 50K temperature rise
Test at temperatures of up and 85% rel. humidity over 24 hours (soak-out period), X  X X
to over 1000 C heating time 60 minutes
50K temperature rise and 85% rel. humidity over 30 minutes,
without soak-out period
X  X 
F120 as system test according to EN 1363 (DIN 4102),
for the design of the room units and their installation modules.
X  X X
F90 as system test according to EN 1363 (DIN 4102),
for the design of the room units and their installation modules.
X   
F180 as component test only according to EN 1363 (DIN 4102), wall system only X  X X
F120 as component test only according to EN 1363 (DIN 4102), wall system only ( )   
F90 as component test only according to EN 1363 (DIN 4102), wall system only    
Explosion Detonation test as system test of 200 kg TNT from 40 m distance X  X X
Water Standing water, 72 hours, 40 cm, 20 droplets maximum X  X X
Fire-ghting water, IP x6 as system test according to EN 605 29,
for the design of the room units and their installation modules.
X   
relative humidity, 85 %, over 24 hours (soak-out period),
60 minute heating time, in accordance with EN 1047-2
X  X X

relative humidity, 85 %, over 30 minutes X  X 


IP 5x as system test according to EN 605 29,
Dust tightness for the design of the room units and their installation modules
X +  
Corrosive re gases Fume/smoke (corrosive gas) tightness based on EN 1634-3 (DIN 18095) X  X 
WK 3 as system test in accordance with EN 1627 / 1630, for the design of the room
Unauthorised access units and their installation modules, e.g. doors
X   
WK 2 as system test in accordance with EN 1627 / 1630, for the design of the room
units and their installation modules, e.g. doors
X   
WK 4 as component test only in accordance with EN 1627 / 1630, door system only X  X X
Debris loads Impact test as system test, 3 lateral impacts of 200 kg from 1.5 m height X  X X
Veried in accordance with tests on comparable components by
EMC protection Aachen Technical University
X   

1 2
System-tested products are tested as a complete design or construction. This includes both the The conventional construction method denotes room constructions made of RIGIPS (gypsum),
room units and their installation modules such as doors, cable ducting or ventilation slides. Com- concrete and other commonly used building materials, which are unable to provide sufcient
ponent tests on the other hand relate to individual parts only. security for data centre applications. In general, conventional construction methods are tested for
use as a re retardant wall.

14 Lampertz
RISK PROTECTOR

What does system tested mean?


System-tested products are tested as a complete design or construction.

IT-Security Rooms
This includes both the room units and all their installation modules such as
doors, cable duct systems or ventilation slides. Only this system test certies
the security for the room structure or design and compliance with important
security standards for the IT security room as a whole.

The simple test of individual components is not very informative in business


critical IT environments and is therefore ultimately not secure enough. Be-
cause the component test only tests the protection class of the individual
component. However, it cannot be used to provide any information whatso-
ever about how the individual components together respond to threats, e.g.
re. These scenarios require a system test, in which it is precisely determined
whether the overall construction of an IT security room or an IT security safe
provides the required protection or not. Only the passed system test provides
customers with adequate security - because it is security at its best!

What is tested?

Fire protection - re test up to F180  Burglary protection - up to WK4 


according to DIN 4102-2 (EN1363) for design of the room units and their according to EN 1627 / EN 1630 for the design of the room units and their
installation modules such as doors, cable ducting and ventilation units. installation modules

Dust protection - IP 5x  Water / re-ghting water protection - IPx6 


according to EN 605 29 for the design of the room units and their according to EN 605 29 for the design of the room units and their
installation modules. installation modules.

Lampertz 15
RISK PROTECTOR

An ECBS certied solution offers more than a component-tested solution


As one of only a two suppliers of security rooms, Lampertz has received In addition to this, an application must be sent to the ECBS for each cus-
ECBS certication for the LSR 18.6 E. tomer project. This application means that the quality of individual projects
will be monitored without warning.
With this certication, the European Certication Board (ECBS) conrms
that the Lampertz IT security room fulls the criteria set by the EN 1047-2 This provides the customer with a guarantee of the highest degree of
standard without limitation. product quality.

Certied and Audited IT Infrastructures Certied IT Security Rooms


Lampertz solutions are specic IT-security concepts which are rounded off The highest level of quality assurance through independent quality
with the certication of the complete IT infrastructure and can form a part of monitoring
the risk management programme implemented in the entire company. In the Transparency for banks and insurance agencies
IT-security sector, TViT offers security certication according to European Standards in Europes IT sectors are harmonized
and international standards at all levels.

Product labelling for certied solutions

16 Lampertz
RISK PROTECTOR

Maximum permissible limit values for data centres and


mini data centre:

IT-Security Rooms
Appropriate protection: Insufcient protection:
System test acc. to EN 1047-2 Lampertz-Solutions Component test according to DIN 4102 / EN 1363

(1440 min)

The entire room (measuring 3 x 2 x 2.8m) with door system, Parts such as walls, ceilings and doors are tested as
cable duct and air-condition slides is tested as a complete system. individual elements.

Evaluation criterions:

Temperature: Temperature:

max. 50 K max. 180 K


(K = temperature increase) (K = temperature increase)

Humidity: Humidity:

max. 85% not tested

Lampertz 17
RISK PROTECTOR

High-availability solution for data centres

Intelligent infrastructure solutions for every data centre


Your security is our strength Modular, exible, economic
Thanks to the modular kit system, our infrastructure solutions such as energy, Working in close dialog with our customers and partners, Lampertz develops
cooling, UPS and monitoring can be adjusted to the growing requirements of reliable infrastructure solutions to satisfy the high requirements of modern
your business at any time especially for existing data centres with current data centres.
need for optimisation.
Single sourcing from one partner
Advantages Specied system and network cabinets and precisely coordinated accessories
Easy and exible integration in existing building structures as an create a suitable room for structured accommodation of your IT components.
overall concept or as individual modules Lasting, perfect air-conditioning is one of the greatest challenges for a data
Modular design ensures future extension capability and long-lasting centre. Individual energy concepts, UPS systems, emergency electricity sup-
economic efciency ply solutions and preassembled wiring realise the optimum energy supply
Demand-oriented design tailored to requirements in scalable and distribution within your data centre even in an emergency. The raised
protection classes ooring installation creates space for the wiring and the air-based general
Consideration of company-wide security policy and economic aspects air conditioning.
Short installation periods (even during system operation) Multi-stage early re detection with active intake system and separate smoke
System-tested solutions analysis provide additional safety and security, even during the incipient
Efcient IT infrastructure solutions with low running costs growth phase of a re. User-friendly and secure access control systems opti-
High level of availability due to live monitoring and remote management mise comprehensive building management. State of the art video surveillance
and other monitoring systems are deployed for continuous remote monitor-
ing of the data centre.

Easy and exible integration


in existing building structures
as an overall concept or
in the form of individual
modules

18 Lampertz
RISK PROTECTOR

Lampertz LSR 18.6 E security room


High-availability solution for data centres and IT system sites. The LSR
18.6 E offers maximum security at any time for hardware systems, net-

IT-Security Rooms
work components and servers - with certificate.

Secure - modular - scalable.

Tailor-made investment security

Modular structure
The modular system structure of the LSR 18.6 E enables this secure high-avail-
ability solution to be both individually adjusted and extended at any time.

Product advantages:
High-availability protection for data centres
Extendable
Dis- and reassembly = investment security
Reduced dust and noise installation
System-tested
Multi-functional risk cover

LSR 18.6 E construction ECBS certication offers


Complex 4-layer element core made of more than component testing certied
thermally effective insulating substances
Robust, encapsulated sheet steel As one of the few suppliers of complete data centres, Lampertz has had the
cassette panels LSR 18.6 E security room certied according to ECBS.
High-security door, ECB-S tested,
multi-point lock, WK 4 With this certication, the European Certication Board (ECBS) conrms that the
Patented connection system LSR 18.6 E fulls all criteria of the EN 1047-2 standard without any reservations
Additional reproof oor elements whatsoever, or even exceeds the requirements.
Use of extremely temperature and
moisture resistant seals Advantages of ECBS certification for customers
Use of air-conditioning/overpressure slides Maximum quality assurance due to
Dis- or reassembly is possible at any time independent quality inspection
Improved rating situation for lending
or residual risk insurance
Transparency for banks and insurance companies
Compliance with European IT security standards

Modular extendability/up-grading Product labelling for certied solutions

Standard protection against:

Fire Fire-fighting Corrosive Vandalism Unauthorised Electromagnetic Dust Explosion Debris loads Theft / burglary Mechanical Bullet-proof
water gases access disturbance access

Lampertz 19
RISK PROTECTOR

Basic protection solutions for your Data Centre

The new Lampertz Efciency Room Advantages

Todays IT environments must be exible, efcient and secure. Only modular Efcient value for money
room systems full all these requirements and also offer fast and clean modi- N Optimum investment utilisation due to growing and modular
cations and extensions. design of the whole data centre
N Full investment protection due to complete dis- and reassembly
of the security room
Lampertz Efciency Rooms (LER) provide uncompromising
exibility and extremely short delivery times. Efcient design
N Optimum space utilisation of the structural circumstances
System tests are state-of-the-art. Why should you as a customer be satis- N Fast nstallation
ed with less security, exibility and long-term benets? Only the system N Ideal for engineering and infrastructure rooms
test of a room construction certies the necessary high security level for IT N Environmentally friendly manufacturing methods
systems and data.
Efcient project completion
N Extremely short delivery times (for basic version = 10 working days)
N Tailor-made data centre solution due to exible modular principle
N Flexibly self-assembly with supervisor

Efcient air conditioning concepts


N Optimum air routing, e.g. cold / hot aisle housing
N Economic air conditioning

System-tested basic protection


N Compliance with current EN and DIN standards
N Multifunctional risk cover (re, water, burglary, ....)

One modular kit endless possibilities Options packages


The heart of the new Lampertz efciency rooms is the modular principle. The The customers requirements are focussed on security, efciency and avail-
basic package already contains solid basic equipment and features and can ability. The LER options packages contain, among other things, solutions for
be adjusted to a customers individual requirements by adding various op- security, systems engineering, air conditioning, energy distribution or moni-
tional modules and components. toring. With these diverse options, IT managers can tailor a precisely-tting
and secure IT made-to-measures suit.
Figure with options

Access control Cable duct Air-conditioning Power supply


system system systems

Fire detection/re Floor system Full assembly and Lighting systems


extinguishing installation

Basic
i package
k
Modular room construction, security functions, door system,
cable ducts, delivery and installation supervisor Monitoring Project mana- Optical package Data and network
gement systems

Standard protection against:

Fire Fire-fighting Corrosive Vandalism Unauthorised Electromagnetic Dust Debris loads Theft / burglary
water gases access interferance

20 Lampertz
RISK PROTECTOR

Lampertz Efciency Room

Modular, secure data centres for basic protection and extended basic protection.
System tested room construction with sheet steel cassette panel construc-

IT-Security Rooms
tion method both for complete data centres, as well as for walls and ceilings.

LER Basic
Lampertz Efciency Room Basic:
Modular, secure data centre for basic protection
standards.

Construction of the LER Basic:


N Fire and heat-retardant element core, consisting of a thermally effective
insulating substance
N Robust sheet steel sandwich elements
N Innovative element connection through stable zinced prole technology
N Security door, F90, up to WK 3
N Use of re protection aps
N Dis- and reassembly possible at any time LER Basic

LER Extend
Lampertz Efciency Room Extend:
Modular, secure data centre for extended basic protection.

Construction of the LER Extend: Note: A system test means testing a complete room construction including
N Fire and heat-retardant element core, consisting of a thermally effective its built in modules such as doors, cable ducts and ventilation slides: Com-
insulating substance ponent tests are not very informative when applied to complete data centres
N Robust sheet steel sandwich elements and server rooms!
N Innovative element connection through stable zinced prole technology
N Security door with additional reproof insulation, F90, up to WK 3
N Special oor seal Your special additional benets:
N Use of temperature and moisture resistant seals
N Use of air-conditioning slides The Lampertz efciency room generation is the rst and only data centre
N Dis- and reassembly possible at any time design on the market for basic protection solutions, which is system-tested
to European standards.

Fire protection: EN 1363 (DIN 4102)


Example of use - infrastructure room: Unauthorised access: EN 1627
The Lampertz efciency rooms, LER Basic and LER Extend, are optimally suit- Watertightness: EN 6 05 29
able for use as an engineering room for the infrastructure components of a Dust tightness: EN 6 05 29
data centre. The air conditioning and power supply systems are equipped with
basic security. The sensitive active components, e.g. servers, are ideally stored
in a high-availability room (LSR 18.6 E) with this design option.
The two room systems are connected with each other using modular ele-
ments. Due to this design, the Lampertz efciency room also has an air lock
function.

LER Extend

Lampertz 21
RISK PROTECTOR

Lampertz Outdoor Data Centre

The outdoor data centre is ready


for use on site - worldwide -
within a very short time.

Figure shows Model L20D

The Lampertz outdoor data centre has been especially developed for tempo- Your advantages
rary use of IT systems. It is an energy-efcient and quickly available solution
for the accommodation of IT hardware and 19 racks and is available, ready NMobility
for installation in a very short time. Can be positioned on any site, indoor or outdoor, which is suitable for instal-
lation of a container. It is possible to change the location at any time.
The connection of a container with features such as free cooling air condition-
ing, extinguishing system, integrated electricity and back-up power supply. NEnergy efciency
This overall package offers secure use with optimised running costs. Air conditioning by means of free cooling technology can save up to
40 % of cooling costs compared to conventional air conditioning units.
The outdoor data centre is especially suitable for companies who would like
to use the Lampertz outdoor data centre to bridge the time while their exist- NPlug & Play solution
ing data centre is being altered or extended, still ensuring availability and The Lampertz outdoor data centre is delivered ready for use:
security. The outdoor data centre can also be used as an independent main Install Plug and wire - Ready!
or back-up data centre.
NAvailability
The IT container is ready for use on site - worldwide - within a very
6000
5800
short time.

NIndividuality
Klima
400/740 The Lampertz outdoor data centre is available with Rittal TS8 quality racks
(basic version not equipped with racks). It is also possible to use a customers
Lsch

Strom Rack Rack Rack Rack Rack USV


Klima 600/1000 600/1000 600/1000 600/1000 600/1000 600/1000 existing 19 racks.
2300
2500

400/600 300/600
400/740
1 2 3 4 5

NProtection properties
Klima
400/740 The place of use can be chosen regardless of the weather. The outdoor data
centre dees the rain, wind, heat and cold and other weather conditions.
100

100
600 Example: L20D option
NMonitoring
1000

Whether with Rittals computer multi control (CMC) monitoring or an existing


system - our customers have full control and an overview of their IT infra-
structures at all times.

NEnvironmental awareness
Environmentally friendly materials and technologies are used. This also ap-
plies to the use of non-toxic extinguishing agents.

N Install Plug and Wire - Ready!

22 Lampertz
RISK PROTECTOR

Lampertz Outdoor Data Centre


The basic version of the outdoor data centre is already a completely
functional system.

IT-Security Rooms
Scope of supply of the basic model:
 IT container
 Air conditioning
 Power distribution
 Raised oor
 Cable ducts
 Access control system

The basic modules of the outdoor data centre


Container:
Steel frame with corrugated sheet facade made in Germany as self-sup-
porting steel frame structure in various RAL colours (standard colour RAL The optional modules
3020 red). Walls, ceiling and oors F30 protection classication.

Dimensions: UPS
External (D x W x H): 6055 x 2435 x 3000 mm Accommodation of the energy efcient UPS in a rack.
Internal (D x W x H): 5727 x 2270 x 2700 mm
Usable area: 13 m2
Weight: approx. 3.5 tonnes Extinguishing system
Floor load: 3500 N/sqm Fully automatic re alarm and extinguishing system incl. early
re detection.
Raised ooring:
300 mm high raised ooring is integrated for air routing and cable manage-
ment. 19 rack system
Depending on the model, up to seven 19 racks can be
Power distribution: integrated.
The scope of supply includes the interior lighting, a working socket, seven
fused outputs for the power supply to the racks, power supply for the infra-
structure components and a multi-meter for monitoring current intensity and Power distribution (to/within) the rack
voltage. Plug & Play power distribution packages available.

Duct:
Two hard ducts are available for the power supply and a for the data wiring Access system
(two further ducts can be optionally integrated). Alternatively, other access systems can be used.

Access system:
The door corresponds to resistance class WK 2. Monitoring
The computer multi control CMC-TC monitors the technical
components and sends error messages..
Air conditioning:
The free cooling technology air conditioning is classied into three capacity
levels: Colours
7 kW 1+1 redundant = approx. 2.000 Euro* The Lampertz outdoor data centre is available in different RAL
14 kW 2+1 redundant = approx. 3.800 Euro* colours.
20 kW 2+1 redundant = approx. 4.600 Euro*

*Savings per year compared to a conventional air conditioning solution and based on an electrici-
ty price of 0.095 euro/kWh. Cable duct
Two additional cable ducts (hard ducts) are also available.

Sun protection
Solar protection is available for outdoor installation.

Service/Maintenance
The service includes one maintenance inspection per year.

Lampertz 23
RACK PROTECTOR

Modular Mini Data Centre


Its easy to secure decentral IT structures with Lampertz Rack Protector Scalability is also proverbial because interlinking, i.e. the combination of two
security safes. The safes provide protection against many different types of or more safes into an overall data centre, is simple. The modular safes are
physical hazards, including re, water, smoke, dust and unauthorised access. not only uncomplicated to install, they can also be easily relocated e.g.
Lampertz has the appropriate solution available for any business security when the business needs to move. Lampertz system of modular safes is as
requirement. Small and medium-sized companies benet from its scaleable straightforward as it is clever. Its exibility and performance are unique on
modular safes. While freelancers and very small businesses may place their the market.
trust in the worlds smallest data centre: Lampertz basic safe.

24 Lampertz
RACK PROTECTOR

Of course, Lampertz is also able to upgrade its security safes with highly And neighbouring network cabinets may be cooled on both sides with the
modern and thus energy-efcient components entirely according to custo- temperature-neutral Liquid Cooling Packages (LCP) concept, which is also
mer requirements. Which means that there is almost no limit to the possible modular and thus easily upgradeable. The optimised cold-air channelling
air-conditioning solutions, system controls, re-alarm and -extinguishing targets hot spots in the racks and ensures that temperatures are evenly
systems. As exible and unique as its customers - modular and basic safes distributed.
by Lampertz.

IT-Security Safes

The modular design that Lampertz employs makes these security


safes considerably more exible. This means that the modular
safes may be installed around racks without interruption to IT
operations and without negatively impacting ongoing work.

Lampertz 25
Lampertz TBU

The Lampertz Total Benet of Usership


The turn-key data centre, More security, exibility and efciency,
more benets for your IT

Lampertz regards Total Benet of Usership (TBU) as the sum of all Your special benets
benets that you as our customer prot from when employing Scaleable security, customized according to your requirements. Solutions
our solutions and services. Both acquisition costs and running costs play that help you achieve exibility and that will grow with your business
an important role in the choice of a partner for your data centre. It is worth and your IT. While ensuring highest cost-efciency. Rittal together: Rittal,
taking a closer look: at lifecycle cost and additional benets that come with Lampertz and LITCOS your strong alliance for complete data centre
a comprehensive solution for your data centre. solutions.

N Turn-key planning and implementation


Base your purchasing decisions N Fastest realization times
on the total benet of your solution N High availability from the start
With Lampertz turn key solutions for data centres, you can ensure high cost N Risk minimization
efciency over your ITs entire life span the all-round no-worry package N Higher power efciency
with comprehensive protection against physical risks by the worlds leading N Protection of environmental resources
specialist who provides security at its best! N Greater exibility for the future

The result
Convincing and most important - illustratable benets for you as our
customer expressed in the Lampertz TBU formula:

Direct benet + additional benet


Costs = Total Benet of Usership

Contact us for your personal TBU consultation


appointment. We will be happy to determine your individual
benets from any of our solutions together with you.

26 Lampertz
Lampertz TBU

The Lampertz Total Benet of Usership - T O T AL


U
Your Lampertz benets an application example

IP - TB

BEN FIT
Z
M P E RTT
LA ENEFI

E
Additional benets from Lampertz Modular Safe LMS 9.3, B

SH
the worlds smallest data centre OF
USER

Customers initial situation: Customers availability requirements:


Existing 42 HU server rack with rack-mounted single-phase UPS system. Continuous IT availability round the clock. Protection of the rack against
The rack is installed in a 25 m room with a three KW wall-mounted air- re, water, extinguishing gases, unauthorised access and vandalism.
conditioning system and smoke detector. This room is also used as an IT
storage room. It has a window front and a standard ofce door without Direct benet from the Lampertz solution:
access control. The server rack is protected by a 42 HU Lampertz Modular Safe LMS 9.3
The walls will provide protection against re for a maximum of 90 minutes. with a redundant 2.4 KW air-conditioning system, CMC monitoring module

IT-Security Safes
Heating and plumbing pipes run along the ceiling. and ultra-compact re-alarm and extinguishing system DET-AC Plus.

Your additional benet with the Lampertz Modular Safe:

Comprehensive infrastructure package:


Higher process reliability and reduced System-tested protection against
failure risk through CMC monitoring. water (IP56). Cost savings: no
necessity for double-walled design of
water-bearing pipes within the IT area.
Improved ratings with insurance
companies due to high multifunctio-
Corrosive smoke gases cannot nal protection of your IT systems.
penetrate and destroy the servers.
Cost savings: no necessity to
install a smoke-proof door. Lampertz
Modular Safe is dust- and water-tight
in accordance with IP 56 and tested
to be smoke-proof. Compact re extinguishing unit.
Cost savings: no necessity to in-
stall a room extinguishing system.

Convincing protection of computing


equipment against sabotage
and vandalism. Cost savings: Efcient air-conditioning due
no necessity to brick-up windows or to minimum space to be cooled
to reinforce them with anti-burglary and direct air ow. Cost savings:
systems. lower power consumption through
reduction of required cooling
performance.

Reduced risk in the event of a re:


Conrmed compliance with maximum No risk from re loads in the direct
values for humidity (85%) and tempe- vicinity. Cost savings: the room
rature (70C) for 30 minutes. can be used for storage as before.

Limitation of liability risks for IT


No server downtimes since installation responsibles through optimum
can be done while systems are interaction of tested components.
running. Immediate use after
installation and hand-over.
Protection of your investment:
relocation is possible at any time.

Lampertz 27
RACK PROTECTOR

LAMPERTZ SECURITY SAFES

Efficient air
air-conditioning
conditioning systems LLampertz
t Early
E l Fire
Fi Detection
D t ti - EFD Pl
Plus Surveillance
S ill control
t l centre
t

Network-capable
N t k bl monitoring
it i Uninterrupted
U i t t d power supply
l
(Computer Multi Control - CMC-TC) (Power Modular Concept - PMC 12)

28 Lampertz
RACK PROTECTOR

IT-Security Safes
Fire-alarm
Fi l and
d extinguishing
ti i hi system
t 19-network-rack
19 t k k Emergency
E power system
t
(DET-AC Plus)

Modular
M d l power distribution
di t ib ti Access
A control
t l
(Power System Module - PSM)

AS MICRO OR MINI DATA CENTRE

Lampertz 29
RACK PROTECTOR

Lampertz Security Safes for ICT Systems


More security for your safe
No company can afford to have their IT and communications systems (ICT)
break down for a longer period of time. It is imperative that such a loss of
information and data be prevented. In addition to this, the IT equipment
must be protected against damage caused by re and water, as well as
uctuations in temperature and voltage. Only the highly developed security
safes, modular safes and basic safes from Lampertz can offer your ICT
systems perfect security.

Scaleable solutions with regard to the companys tolerable IT downtime

Explanation of symbols on the following pages:

Fire Fire extingu- Corrosive Vandalism Unauthorized Dust Explosion Debris Theft/burglary Mechanical
ishing water gases access access

30 Lampertz
RACK PROTECTOR

Overview RACK PROTECTOR

IT-Security Safes
Type LBS 9.1 C LBS 9.1 C LBS 9.1 C LBS 9.1 C LMS 9.3 LMS 9.3 LMS 9.3 LMS 9.3
15 HU 15 HU 15 HU 15 HU 42 HU 42 HU 47 HU 47 HU
Fire protection F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102 F 90 / DIN 4102

Compliance of 10 mins. 10 mins. 10 mins. 10 mins. 30 mins. 30 mins. 30 mins. 30 mins.


limit values*

Burglar protection WK2 WK2 WK2 WK2 WK 2 WK 2 WK 2 WK 2


opt. WK 3, WK 4 opt. WK 3, WK 4 opt. WK 3, WK 4 opt. WK 3, WK 4
Water IP 55 IP 55 IP 55 IP 55 IP 56 IP 56 IP 56 IP 56

Dimensions exterior (mm)


Height 1646 1646 1699 1699 2210 2210 2410 2410
Width 806 806 806 806 1100 1100 1100 1100
Depth 1119 1319 1119 1319 1200 without air-con. 1400 without air-con. 1200 without air-con. 1400 without air-con.

Dimensions interior (mm)


Height 827 (usable) 827 (usable) 827 (usable) 827 (usable) 2030 2030 2230 2230
Width 620 620 620 620 920 920 920 920
Depth 824 1024 824 1024 1000 1200 1000 1200

Weight approx. (kg) 299 330 319 360 760 800


(without interior equipment) air-con. 1,3 kW air-con.1,3 kW air-con. 2,4 kW air-con. 2,4 kW

* $T < 50 K, max. rel. humidity < 85 % HU: Height unit in mm (1 HU = 44,45 mm)

Lampertz 31
IT-Security Safes

The
Lampertz
Lampertz
Modulsafe
- LMS 9.3
LMSMini
9.3Data Centre
Functional security for network technology Advantages:
The LMS 9.3 provides complete security for one or multiple 19-racks.
Certainly Lampertz infrastructure solutions like independent climatisation Extended basic protection for your system security
system, power supply and efcient re-alarm and extinguishing system can Protects against potential physical threats like re, water, smoke
be integrated into the LMS 9.3 according to your demand. Modular, exible, extendable
Individual energy-efcient air-conditioning concept up to 28 KW
Installation without IT downtime

Modular Safe LMS 9.3

The basic models (42 HU and 47 HU) are equipped as follows:


Modular housing design
Linkage system can be extended to the left and right
Operator and service door
Tested cable duct systems in both side elements
Prepared for compact air-conditioner
Lock with two keys

Available in:
42 HU or 47 HU
as a single safe or as a linkage system containing 2, 3 or 4 units
(single safe can be extended at any time as a linkage system)
Dimensions internal 1000 mm or 1200 mm
Technical data
Type 42 HU 47 HU
External dimensions in mm
Height 2210 2410
Width 1100 1100
Depth 1200/1400 1200/1400
(Closed doors without air-con.)
Depth 1520/1720 1520/1720
(with air-con.)
Internal dimensions in mm
Height 2030 2230
Width 920 920
Depth 1000/1200 1000/1200

Total weight in kg
(without interior ttings) 760 800

All safes without contents/decoration

Fire proof and access-controlled storage of network and hardware components.


Colour:

Light grey, RAL 7035 Operator door red, RAL 3020. Alternative colours available upon request.

The Lampertz Modular Safe LMS 9.3 offers physical hardware protection on a high security level.
Fire protection F 90 within the IT-limit values, max. 50 K temperature increase and 85 % humidity for more than 30 minutes..
Burglary protection WK 2 / optional WK 3 and WK 4. IP 56 protection against extinguishing water and dust penetration.
All tests have been realised as system test and are certied for this purposes.
Standard protection against:

Fire Fire extingu- Corrosive Unauthorized Vandalism Debris Dust


ishing water gases access

32 Lampertz
Modular Safe LMS 9.3

Enlargement according to individual needs Several levels of IT growth


In the age of 19-technology, there is a wide range of racks with The advantages:
19-inch equipment in almost all IT areas.
These servers and 19-units are often connected using patch cables. Today, Physical hardware protection on a high security level with burglary and
even these highly-sensitive hardware units can be protected with re and re protection, tightness against extinguishing water and smoke gases.
access protection:
Multifunctional security solution for19-technology, network/ hardware
components.
With the modular safe linkage system by Lampertz!
Modular safes can be easily linked together with the modular components Modular, mobile security due to unique connecting technology.
while the hardware is running. Each element is equipped with a control and Without system interruptions reproof and burglar-proof components
service door, as well as customer-specic accessories. can be installed next to existing, already equipped network and server
cabinets.
One product multiple possibilities
absolute security for 19-technology. Relocation or enlargement is easy and uncomplicated.

IT-Security Safes

Lampertz 33
IT-Security Safes

Lampertz Modular Safe LMS 9.3


Lampertz Mod. Safe LMS 9.3 standard depth 1000 mm Order no.
LMS 9.3 Single 42 HU Interior depth 1000 mm 110010502010
LMS 9.3 Linking left 42 HU Interior depth 1000 mm 110010502011
LMS 9.3 Linking middle 42 HU Interior depth 1000 mm 110010502012
LMS 9.3 Linking right 42 HU Interior depth 1000 mm 110010502013
LMS 9.3 Single 47 HU Interior depth 1000 mm 110010502000
LMS 9.3 Linking left 47 HU Interior depth 1000 mm 110010502001
LMS 9.3 Linking middle 47 HU Interior depth 1000 mm 110010502002
LMS 9.3 Linking right 47 HU Interior depth 1000 mm 110010502003

Equipment options Order no.


Cable duct in top element 110010576100
Cable duct in oor element 110010576101
Hard bulkhead for each cable duct in the side element 110010576102
Operator door hinge right 110010576104
Service door hinge left 110010576105
Double-winged door 110010576106
Electronic code combination lock 110010576107
Electronic lock for code card reader 110010576108
(Code card reader not included in scope of delivery)
Common locking, control and service door 110010576109
Side element in two parts for standard depth 110010576121
Increased burglary protection, class WK III 110010576122
Increased burglary protection, class WK IV 110010576123
Socket for modular safe with cable duct in oor element 110010502200
Interior depth 1000 mm
Socket for modular safe with cable duct in oor element 110010502300
Interior depth 1200 mm
Modular safe socket for a compensation of the raised oor height upon request

Installation and transportation costs Order no.


Installation single Modular Safe LMS 9.3 110019911991
Operator door Installation double linking LMS 9.3 110019911992
Installation triple linking LMS 9.3 110019911993
Installation quadruple linking LMS 9.3 110019911994
Cable duct closure for 2 ducts incl. journey 110019911982
Additional cable duct closure 110019911983

19-Racks Dimensions in mm Order no.


19-Rack 42 HU 2000 x 800 x 1000 7995969
19-Rack 47 HU 2200 x 800 x 1000 7995970
19-Rack 42 HU 2000 x 600 x 1000 7995971
19-Rack 47 HU 2200 x 600 x 1000 7995972

Lampertz Mod. Safe LMS 9.3 special depth 1200 mm Order no.
LMS 9.3 Single 42 HU Interior depth 1200 mm 110010503010
LMS 9.3 Linking left 42 HU Interior depth 1200 mm 110010503011
LMS 9.3 Linking middle 42 HU Interior depth 1200 mm 110010503012
LMS 9.3 Linking right 42 HU Interior depth 1200 mm 110010503013
LMS 9.3 Single 47 HU Interior depth 1200 mm 110010503000
LMS 9.3 Linking left 47 HU Interior depth 1200 mm 110010503001
LMS 9.3 Linking middle 47 HU Interior depth 1200 mm 110010503002
LMS 9.3 Linking right 47 HU Interior depth 1200 mm 110010503003

19-Racks Dimensions in mm Order no.


19-Rack 42 HU 2000 x 600 x 1200 7995164
19-Rack 47 HU 2200 x 600 x 1200 7995163
19-Rack 42 HU 2000 x 800 x 1200 7995974
19-Rack 47 HU 2000 x 800 x 1200 7995973

Detailed information can be found on pages:


Air-conditioning systems Page 46
Uninterruptible power supplies PMC 12 Page 54
Early re detection system EFD Plus Page 64
Fire extinguishing System DET-AC Plus Page 66
All safes without contents/decoration Service door Network-capable monitoring CMC-TC Page 80
19-network-rack Page 68

34 Lampertz
Modular Safe LMS 9.3

Measurements Lampertz Modular Safe LMS 9.3

Modular Safe 47 HU (42 HU) with 2 single doors

IT-Security Safes
Modular Safe 47 HU (42 HU) with one single-door and one double-winged door

Article Ta Ta1 Ta2 Ti Ha Hi Order no.


in mm in mm in mm in mm in mm in mm
LMS 9.3, 47 HU, standard depth 3324 2854 1204 1000 2410 2230 110010502000
LMS 9.3, 42 HU, standard depth 3324 2854 1204 1000 2210 2030 110010502010
LMS 9.3, 47 HU, special depth 3524 3054 1404 1200 2410 2230 110010503000
LMS 9.3, 42 HU, special depth 3524 3054 1404 1200 2210 2030 110010503010

Lampertz 35
IT-Security Safes

Air-conditioning Lampertz Moduar Safe LMS 9.3


Hardware components accommodated in the modular safe need an opti- ranging between 1.2 and 12 kW, and thus eliminate the specic heat dissi-
mum process climate. For this purpose, the air-conditioning for Lampertz pation losses inside the safe. A variety of air-conditioning solutions adapted
LMS 9.3 modular safe may be adapted to performance requirements to the respective buildings demands may be employed.

Compact air-conditioning for the LMS 9.3 Outdoor air-conditioning for the Lampertz Modular Safe LMS 9.3
The principle of compact air-conditioning is simple but effective: the air- In the outdoor version, the air-conditioners interior circulation system is
conditioning units inside circulation system is installed inside the safe on installed inside the safe on the side element of the safe, the external unit is
the side wall of the safe, the external unit is positioned on the service door. weatherproof and therefore may be tted on the outside of the building. The
Both circulation systems are interconnected by exible coolant tubes tted cooling and control pipes are installed by a refrigeration systems engineer.
through a cable duct in the door. In the same way as with the compact air-conditioning unit, the warm air
The warm air from the servers is extracted by the fans inside the rear of the from the servers is extracted from the rear of the safe and the cooled air is
safe while the cooled air is blown admitted in front of the 19-level. All blown in front of the 19- level. Benets of the outdoor model: the waste
air-conditioning systems are split designs to enable the cooling circulation heat is discharged into the open air. This makes ventilation or air-conditio-
systems inside and outside the safe to be hermetically separated. Thus ning in the room unnecessary. Also, the operating noises are moved outside
creating protection against smoke for both the air-conditioning unit as well the building thus allowing this modular safe to be installed in ofces.
as the entire safe.
The compact split air-conditioning unit is suitable for use in rooms already
possessing air-conditioning or sufcient ventilation and that make low or no
demands on admissible noise levels.

Compact air-conditioning Order no. Outdoor air-conditioning Order no.


2400 W, compact 803867 2400 W, Outdoor 803871
for service door DIN left and double-winged door 2400 W, Outdoor with redundancy 803870
2400 W, compact 803868 5000 W, Outdoor 803875
for service door DIN right
5000 W, Outdoor with redundancy 803873
3800 W, compact 803542
for service door DIN left and double-winged door Optional innovation
3800 W, compact 803543 Outdoor-climatisation 6000 Watt Outdoor on request
for service door DIN right
Cooling pipes 20 linear meters incl. electrical control cable for 2.4 kW 811757
2400 W, compact with redundancy 803866
10 KW, Outdoor 110010576220
for service door DIN right
Cooling pipes 20 linear meters incl. electrical control cable for 5 kW 821870
2400 W, compact with redundancy 803867
for service door DIN left
Extension of the cooling pipes for the compact air-conditioning 808533
Installation Outdoor air-conditioning Order no.
of a modular safe with a special depth
4000 Watt, compact for all service doors 3126240 Installation 2,4 kW Outdoor air-conditioning 110019911995
Installation 2,4 kW Outdoor air-conditioning with redundancy 110019911996
Installation 5 kW Outdoor air-conditioning 110019911997
Installation 5 kW Outdoor air-conditioning with redundancy 110019911998
Installation 10 kW Outdoor air-conditioning 110019911990

36 Lampertz
Modular Safe LMS 9.3

High-Performance Cooling modular, scalable, efcient


Despite a dramatic rise in climate control requirements, cooling practice in The modular conguration and scalability of the climate control innovation
many companies has changed little in decades. Traditional room tempera- Liquid Cooling Package (LCP) help to minimise investment costs and
ture control concepts soon reach their limitations. The consequence: High maximise investment condence, while providing sufcient scope for future
on-going operating costs, low levels of efciency, a lack of investment extension.
condence, and reduced operational reliability.

IT-Security Safes
Liquid cooling package Cover plates
The liquid cooling package (LCP) may be integrated inside the modular safe The front of the 19- rack must be completely closed off to ensure optimum
combined with a 600 mm wide 19- rack. The LCP possesses a modular air circulation and air-conditioning inside the modular safe. The cover plates
design, consisting of three air-water heat exchangers: Thus the cooling listed are for closing off unoccupied rack units.
performance may be increased responding to growing requirements within
4 kW steps (with a lead water temperature of 15C, ow rate of 15 litres/
minute).

This creates a continuous air-conditioning cycle: the heat radiation from


the servers is extracted over the entire height at the rear of the safe and
discharged through the air-water heat exchanger to a cold-water network
or chiller. The cooled air is then blown again in front of the 19 level at tem-
peratures ranging between 22 and 25C. The LCP is an airtight system that
does not set up any requirements regarding the rooms air-conditioning.

Liquid Cooling Package (LCP) Order no. Article Order no.


LCP for LMS 47 HU 3301.230 Dummy plate, 1 HU 1931200
LCP accessory package 47 HU 110010571500 Dummy plate, 2 HU 1932200
Additional 4 kW cooling module 3301250 Dummy plate, 3 HU 1933200
LCP Plus for LMS 9.3, interior depth 1200 mm 3301480 Dummy plate, 4 HU 1934200
Dummy plate, 6 HU 1936200
Dummy plate, 8 HU 1938200
One LCP includes the cooling rack and one cooling module.
The maximum extension contains 3 cooling modules (12 kW).
Description of Liquid Cooling Packages on page 50.

Lampertz 37
IT-Security Safes

Lampertz Modular Safe LMS 9.3 Solution Packages price advantage by a complete service package
The basic, extend and premium solution packages permit the installation of
Basic complete mini data centres in several sizes.
One product multiple possibilities absolute security for 19-
hardware.

Lampertz LMS 9.3 Modular Safe Solution Package Basic


19-network-rack
This Lampertz solution constitutes the basis for secure IT in businesses.
For the installation of network
Simple upgrading is possible at any time and that without interruption to
components
operations.

The Solution Package Basic is available with compact air-conditioning offe-


ring 2.4 kW cooling performance, monitoring of interior room (CMC-TC) and
a 19- network-rack (42 HU). The Solution Package Basic is only available
for the modular safe with a 42 HU height. Other optional features are also
CMC-TC available for their integration into this package.
Interior surveillance of the
Lampertz Modular Safe (interior Secure, exible, compact.
temperature, air-con. status,
LMS 9.3 Solution Package Order no.
status of the re-alarm and
LMS 9.3 Solution Package Basic 110010502021
extinguishing system)

Standardised mini data centre, basic version


Lampertz Modular Safe, 42 HU, interior depth 1000 mm
Control and service door with key lock
Cable entry (soft bulkhead) in both side elements
Compact climate control, 2.4 kW cooling output
(19) network-rack
CMC-TC network-compatible monitoring

Lampertz LMS 9.3 Modular Safe Solution Package Extend


Extend This Lampertz solution is the enhanced component for professional security
technologies with built-in exibility and modularity. Additional components
providing protection against re signicantly improve the Extend package.

19-network-rack The Solution Package Extend is available with compact air-conditioning


For the installation of network offering 2.4 kW cooling performance, monitoring of interior room (CMC-TC),
components a 19- network- rack (42 HU) and an early re detection and -extinguishing
system. The Solution Package Extend is only available for the modular safe
with a 42 HU height. Other optional features are also available for their
integration into this package.

Secure, modular, variable.

CMC-TC LMS 9.3 Solution Package Order no.


Interior surveillance of the LMS 9.3 Solution Package Extend 110010502022
Lampertz Modular Safe (interior
temperature, air-con. status, Standardised mini data centre, extended version
status of the re-alarm and Lampertz Modular Safe, 42 HU, interior depth 1000 mm
extinguishing system) Control and service door with key lock
Cable entry (soft bulkhead) in both side elements
Compact climate control, 2.4 kW cooling output
(19) network-rack
Fire extinguishing CMC-TC network-compatible monitoring
System DET-AC Plus early re-detection and -extinguishing system
DET-AC Plus
Earliest smoke detection in
19-technology

38 Lampertz
Interior Fittings
Modulsafe
Modular
LMSSafe
9.3

Lampertz LMS 9.3 Modular Safe Solution Package Premium


Premium This Lampertz solution is the premium set for a mini data centre composed
by two modular safes interlinked in line providing high levels of security and
19-network-rack high-performance cooling.
For the installation of network
components The Solution Package Premium is available with a Liquid Cooling Package
(LCP) offering 8 kW cooling performance, including accessories, monitoring
of interior room (CMC-TC), a 19- network-rack (47 HU), an early re de-
tection and -extinguishing system and power system modules (power rails).
The Solution Package Premium is only available for the modular safe with a
47 HU height.
CMC-TC Secure, complete, unique.
Interior surveillance of the

IT-Security Safes
Lampertz Modular Safe (interior
temperature, air-con. status, LMS 9.3 Solution Package Order no.
status of the re-alarm and LMS 9.3 Solution Package Premium 110010502023
extinguishing system)
Standardised mini data centre, premium version
Lampertz Modular Safe, left linkage , 47 HU, interior depth 1000 mm
Fire extinguishing Control door with electronic lock, service door with key lock
System DET-AC Plus Cable entry (soft bullthed) in the left side element
Early smoke detection in Lquid Cooling Package with 8 kW cooling output, including accessories
19-technology (19) network-rack
CMC-TC network-compatible monitoring, incl. leakage detection
DET-AC Plus ealry re-detection and -extinguishing system
PSM power rail with 1 x safety module, 2 x C19 modules,
2 x C13 modules

Power System The right module of the linkage can be chosen individually.
Modul - PSM
Power rail, with comprehensive
electric shock protection, moun-
ted in the rack

Liquid Cooling
Package (LCP)
Redundant cooling system that
guarantees the automatic regu-
lation of the cooling performance
according to the IT requirements

Fire proof and access-controlled storage of network and hardware components.


Colour:

Light grey, RAL 7035 Operator door red, RAL 3020. Alternative colours available upon request.

The Lampertz Modular Safe LMS 9.3 offers physical hardware protection on a high security level.
Fire protection F 90 within the IT-limit values, max. 50 K temperature increase and 85 % humidity for more than 30 minutes..
Burglary protection WK 2 / optional WK 3 and WK 4. IP 56 protection against extinguishing water and dust penetration.
All tests have been realised as system test and are certied for this purposes.
Standard protection against:

Fire Fire extingu- Corrosive Unauthorized Vandalism Debris Dust


ishing water gases access

Lampertz 39
IT-Security Safes

The micro data centre made by Lampertz


Rack Protector Lampertz Basicsafe LBS 9.1 C Optional:
With the Basic Safe LBS 9.1 Compact Lampertz presents the smallest fully air-
conditioned data centre of the world. For medium sized companies we offer
herewith a cost efcient possibility to store tape libraries or single 19- servers.

19- network-rack
19 t k k
INNOVATION! For the installation of network
components

CMC-TC
CMC TC
Interior surveillance of the
Lampertz Modular Safe (interior
temperature, air-con. status,
status of the re-alarm and
extinguishing system)

Early Firee Detection -


EFD Plus
Earliest smoke detection in
19-technology

Fire alarm and extingu


Fire-alarm extingu-
ishing system DET-AC
Plus
Early re detection in 19-tech-
nology and automatical extin-
guishing

Uninterrupted
power supply
(Optionally 1; 1.5; 2 or 3 kVA)

All safes without contents/decoration

40 Lampertz
Basic Safe LBS 9.1 C

The smallest air-conditioned data centre in the world

RACK PROTECTOR Basic Safe LBS 9.1 C


The new compact Lampertz Basic Safe LBS 9.1 C (Compact) Rack
Protector delivers more exibility regarding the equipment. The LBS 9.1 C
possesses a lower height of only 15 height units. This means that small and

IT-Security Safes
medium-sized companies may also benet from protective features adapted
to the employed IT systems.

The Basic Safe Compact features an approved cable duct in the side element
and is fully air-conditioned (1.3 or 2.4 kW).

Description of standard equipment


Security housing with operator door and service door
(three-point locking system)
Cable duct system in both side elements
Air-conditioning unit, 1.3 kW / 2.4 kW
Usable internal height, 15 HU

Compatible equipment:
Early re detection system - EFD Plus
Monitoring - CMC-TC
Fire-alarm and extinguishing system DET-AC Plus
Uninterrupted power supply - PMC 12
19-network-rack

Applications:
Micro data centre for medium-sized companies
Protection for servers, storage applications and network components
Can also be integrated in smaller ofce areas
For storing personal data, e.g., in doctors surgeries and tax
consultancy ofces
Type Interior depth Usable (interior) dim. External dim. Weight Order no.
in mm in mm in mm incl. a/c
LBS 9.1 C, with two doors and socket*, air-con. 2.4 kW 800 827 x 620 x 824 1699 x 806 x 1119 approx. 319 kg 110010399100
LBS 9.1 C, with two doors and socket*, air-con. 2.4 kW 1000 827 x 620 x 1024 1699 x 806 x 1319 approx. 360 kg 110010399200
LBS 9.1 C, with two doors and socket*, air-con. 1.3 kW 800 827 x 620 x 824 1646 x 806 x 1119 approx. 299 kg 110010399300
LBS 9.1 C, with two doors and socket*, air-con. 1.3 kW 1000 827 x 620 x 1024 1646 x 806 x 1319 approx. 330 kg 110010399400

19-network-rack for Basic Safe 800 x 600 x 800 7995991


19-network-rack for Basic Safe 800 x 600 x 1000 7995992
*Socket can be accessed from below

Fire proof and access-controlled storage of network and hardware components.


Colour:

Light grey, RAL 7035 Operator door red, RAL 3020. Alternative colours available upon request.

System tested according to DIN 4102.


Fire protection F 90 according to DIN 4102, max. 50 K temperature increase and 85 % humidity within the limit values for more than
10 minutes. Protection against unauthorized access.

Standard protection against:

Fire Water Unauthorized Dust Vandalism Theft/


access Burglary

Lampertz 41
Infrastructure Solutions

COMPLETE SOLUTIONS FOR

Air-conditioning systems Power supply units UPS equipment

Early fire detection system Fire-alarm and extinguishing system Access control

42 Lampertz
Data Centre Solutions

Infrastructure Solutions
Infrastructure Solutions
Double flooring Cabling Network cabinets and accessories

Monitoring system Video surveillance Service

DATA CENTRES

Lampertz
Lamp
perrtz
t 43
RimatriX5

44 Lampertz
IT Performance

Choose complete
system solutions:
scalable, flexible,
modular, efficient.

RimatriX5
RimatriX5: For all aspects of your IT performance

DiThe most important factors of any IT performance are security and availability, coupled with maximum cost-effectiveness.
As all these requirements continue to escalate, planners are faced with an apparent dilemma security and availability
versus cost-effectiveness. Not so with Rittal RimatriX5, where the two are in perfect balance. The result is whats known
as efciency, building on Rittals tried-and-trusted full-service philosophy. This means expert advice from the word go, and
continuously thereafter, throughout the installation and sales phase and beyond.

RimatriX5 is an integral, complete solution. Everything centres around your IT performance, embedded into a perfectly
coordinated concept with ve hardware modules: Racks, Power, Cooling, Security, Monitoring & Remote Management,
rounded off by a comprehensive range of services.

RimatriX5 is Rittals response to the ever-growing momentum in the IT market. Despite a constant wave of new developments
at ever shorter intervals, RimatriX5 stands out from the crowd, thanks to its optimum availability and value for money. In
short, RimatriX5 is synonymous with IT performance from a single source, and comprehensive, expert advice included as
standard.

Lampertz 45
RimatriX5

The latest concept in


secure, modular and efficient
IT infrastructure has a name:

Cooling

Power Security

Rack Monitoring +
Remote Management

46 Lampertz
IT Performance

Rittal server racks:


High-tech
with savings effect.

RimatriX5
Rittal IT rack TS 8:
Flexible
applications,
optimised
design.

The performance of any IT infrastructure is reliant upon interaction between individual components. With
Rittal RimatriX5 server racks, you have a system platform in which the climate control, power and security
solutions are perfectly coordinated with one another, and the existing space optimised. The performance
per IT rack is signicantly increased, while your xed costs are permanently reduced.

Rittal RimatriX5 aims to maximise the efcient use of space. The IT racks may be exibly arranged, have a favourable
inuence on investment costs, and help to slash running expenses. The system centres around the hugely popular and well-
established TS 8 system platform. The stable frame structure of the TS 8 facilitates simple, versatile installation with a high
packaging density for servers, storage, switching etc.

Lampertz 47
RimatriX5

Rittal Power
Management:
Availability up.
Costs down.

Rittal PMC UPS


systems:
Innovative
power supply
protection.

The system availability and reliability of the IT infrastructure have a crucial inuence over the efciency and
productivity of company processes which in turn determines business success. Interrupting critical business
processes may have far-reaching adverse effects for a company; the consequences can include hardware
defects, production downtime and communication failures. Failure to provide adequate protection against
against voltage problems can likewise lead to computer and production downtime.

The rising performance of hardware components, coupled with a simultaneous trend towards miniaturisation, places
particular requirements on modern energy management. The answer to this dilemma? Power management with RimatriX5.
It meets all demands in terms of redundancy, scalability and maximum availability, all bundled into a single system. This
ingenious solution helps to reduce operating costs and boost the availability of the overall system. It is even possible to
retrot new modules without interrupting operation. One particularly effective feature is the modular, rack-mounted N+1
technology, which ensures intelligent redundancy and enhances availability. The Power Modular Concept PMC with its
innovative Decentralised Parallel Architecture (DPA) provides the ultimate in availability combined with an outstanding
operating ratio even at low capacity utilisation (UPS classication VFI-SS-111).

48 Lampertz
IT Performance

Rittal cooling:
Cool heads
for hot performers.

RimatriX5
Rittal LCP: Scalable
climate control concept
for high-performance
cooling.

In order to avoid thermal problems in data centres, there is a demand for new, modular climate control
concepts which are efciently and precisely tailored to the current requirements, while at the same time
accommodating future growth.

Holistic cooling solutions from a single source


N Passive cooling (use of the ambient air)
N Active, rack-based cooling
N High-performance cooling for temperature-neutral data centre expansion
N Holistic climate control solutions including raised-oor congurations, pipework,

IT chiller and free-cooling

In each case, the systems are customised exactly to your specications and application requirements, taking into consideration
all ambient conditions. Thanks to the use of state-of-the-art technology, Rittal cooling solutions offer signicant cost
savings, a crucial consideration in these times of rising energy prices.

Lampertz 49
RimatriX5

Rittal Multi Control:


Greater confidence
through prevention.

Extensive
IT security
with Rittal
CMC-TC.

The dened availability of their information technology is, for most companies, the decisive prerequisite
for reliable and properly controlled business processes. This security of the physical IT infrastructure begins
with each individual rack.

The Computer Multi Control Top-Concept (CMC-TC) from Rittal is a complete security management for preventive protection
to guard against consequential costs, which simultaneously serves as the central organisational unit for linking to the facility
management.

N Fault and alarm messages are sent to dened service or security management systems. Data exchange via bus systems and
integration into LAN and building management congurations ensure the transparency of all security-relevant data.
N Rittal video technology combined with the CMC-TC monitoring system affords perfect all-round protection, thanks to

comprehensive visual and alarm-controlled monitoring.


N The modular concept permits tailoring to individual requirements, while automatic sensor detection enables the system to

be expanded using plug-&-play or 2.4 GHz wireless technology.

Because it incorporates various different preventive aspects and can also be linked into central facility management systems,
CMC-TC advances to become the central point of information in the data centre.

50 Lampertz
IT Performance

Monitoring and
Remote Management:
Security cockpit for
your IT infrastructure.

RimatriX5
Rittal Remote
Management
reduces
downtime risks
to a minimum.

Thanks to the perfect interaction between the physical security devices of Rittal CMC-TC and remote
management, on-going costs may be signicantly reduced with RimatriX5. After all, targeted remote
maintenance and diagnosis for sensitive parameters extends the service life of active components.

Server administration and remote maintenance with Rittal SSC KVM technology and the new remote
management software, all from a single source.

The temperature variations of racks, components and climate control technology may be analysed and administered, the
operating status of UPS systems is documented, video monitoring of the room and systems is ensured, power supply is
actively structured right down to the individual module, and the operating hours of batteries and fans are preventively
evaluated all from the same software interface. This sets new standards in the remote management of data centres.

In practice, Rittal KVM switches offer the right solution to suit any customer requirements, from local stand-alone solutions
for 8 to 32 servers, through to complex KVM-over-IP multiuser systems for data centre applications with up to 2048
computers.

Lampertz 51
Infrastructure solution

Ecological responsibility - economic availability


A combination which is becoming increasingly important. It is not only
reasons of cost which make energy efciency the central topic for economic
and secure operation of data centre structures!

Annual expenditure worldwide for new servers, electricity and cooling


(in bln US dollar)*

* Source: IDC/WiWo No. 28 dated 09.07.2007

According to statements made by BITKOM and the Gartner Group, electricity next ve years. Therefore, we must act now to identify and implement
costs for the operation of services and data centres will double within the potential savings.

We help you to achieve this!


And these are the specic measures we use:

N Energy measurement
N Electricity consumption of the individual devices and units
N Determination of the running times per unit time of the
individual units
N Determination of the efciencies of the electricity loads

N Measurement of the closed circuit air conditioning


N Pressure
N Temperature
N Speed
N Volume / unit of time

N Measurement of the room and rack temperatures N We show you where the savings potential is in your data centre.
N Individual units/devices N We can show you how to use these to your advantage.
N Complete racks N We show you - if there are any - your hotspots or the places in
N Pressure raised ooring which cold air inadvertently escapes.
N Ceiling areas
N Entrance and intermediate areas (hot and cold states) These measures will help you to design the future of your IT infras-
N etc. tructures effectively, ecologically and above all, economically.
Ihr Budget und die Umwelt werden es Ihnen danken!
It is possible to cut energy consumption and therefore to directly cut costs - if
you know how and where. Naturally, this extensive check does not limit or You budget and the environment will thank you!
endanger either the availability or the performance of your IT systems.

52 Lampertz
Data centre solutions

Tier classication for the data centre infrastructure


The Uptime Institute in the USA has dened a so-called Tier Classication
Tier I Tier II Tier III Tier IV
Supply 1 System 1 System 1 system 2 systems
Supply paths 1 1 1* normal + 2* simultaneously active
1* alternative
Redundancy 1 N+1 N+1 Minimum N+1
Spatial separation No No Yes Yes
Alternating maintenance possible No No Yes Yes
Error tolerance (compared to individual No No No Yes
errors)
"Single point of failure" Many + human error Many + human error Few + human error None + only re and EPO
Availability 99.67% 99.75% 99.98% 99.99%

Infrastructure Solutions
The denition
Tier I is suitable for the following businesses: IT customers expect an availability of 5 * 9 or in other words, 99.999 %.
Smaller businesses in which IT is primarily used to handle internal processes, However, most of a companys investment is still made in the IT hardware
rms whose internet presence is a purely passive display; and start-up com- and software security, without thinking that the ve nines cannot be
panies which do not yet need computer-assisted customer support. achieved without comparable commitment to the infrastructure. The tier
classication depends on all parts of the infrastructure. The lowest value of
Tier II is suitable for the following businesses: an individual trade (cooling, power supply, communication, monitoring, ...)
Smaller businesses whose IT is mostly used during the usual ofce and busi- determines the overall rating. It is important to note that the sustainability
ness hours only, so that it can be switched off after business ends without of the measures, i.e. the operating and service processes in the data centre,
any problems; these are typically computer systems for software developers are also incorporated in the rating. This is especially clear when jumping
(important in case of night-time running), CAD ofces, or rms which use from Tier II to Tier III, where the alternative supply channel allows mainte-
their internet link for business purposes but in case of non-availability nance without having any signicant effect on operation, which is in turn
only risk delays and data losses, but no critical business delays. reected in the so-called MTTR (Mean Time To Repair).

Tier III is suitable for the following businesses: We show you ways and, together with you, draw up solutions which are
Businesses or service providers who should be operational around the tailored to your needs.
clock for their internal and/or external customers, e.g. in service centres or
emergency service facilities, but nevertheless can also be reached in other
ways and are able to work if the computers do not work for a short time.
Firms whose IT equipment are used for electronic business purposes, but
no impairment results for the customer during maintenance or shutdown
periods; and rms which operate in different time zones in such a way that
different regional business times do not cause any impairments.

Tier IV is suitable for the following businesses:


Businesses with an international market presence, which must reliably provi-
de a service 24 hours a day for 365 days a year in order to stay competitive;
rms based on e-Commerce, electronic market transactions or nancial ser-
vices as well as worldwide operating corporations which operate in several
time zones, so that employees can access important resources at any time
and their customers can use the most up to date applications.

Lampertz 53
Air-conditioning Systems

Lampertz air-conditioning solutions


We provide air conditioning for the operators of data centres who plan to
build a new IT area or extend their existing IT area. Our solutions set them-
selves apart due to their high degree of exibility and solutions individually
tailored to your task.
We have the suitable solution for hot spots and network cabinets with
extreme heat generation.

7
10

9 8

6
5

1
2

All air conditioning solutions


from a single source:
1 cold/hot aisle housing
2 Closed circuit air conditioning systems
3 LCP standard/plus/modular
4 + 8 Water/water heat exchangers
5 IT chiller
6 Double pump unit
7 Heat recovery
9 Buffer storage
10 Emergency water supply

54 Lampertz
Air-conditioning Systems

Lampertz oor-mounted air-conditioning systems

LPA Lampertz Precision air-conditioning Redundancy (Reserve)


Precision air-conditioning and reliability are of the utmost importance if A redundant air-conditioning system must be used in data rooms with high
malfunction-free processes are to be secured for data rooms, telecommuni- demands on IT-availability. Due to the high heat output of todays computer
cations centres, data centres and technical applications. Lampertz products systems, should the air-conditioning system fail, this would lead to a
have always industrial standards but, nowadays, there is a demand for increase in temperature which would be impermissible for computer systems
more than just precision air-conditioning and reliability must higher levels and thus cause them to crash. This crash can be prevented through
of global functions are required. In addition to precision air-conditioning, redundancy.
the new Lampertz LPA series sets new standards in the elds of energy
efciency, compactness and noise emissions. A 100% redundancy can be applied in most cases for wall and ceiling-
mounted usits with a low cooling capacity. When it comes to higher
High Standards for Performance and Efciency demands on performance and thus for oor-mounted air-conditioning
The use of fans with free-running blades, generously-sized heat exchangers, systems, a n+1 redundancy system should be introduced, i.e., n-units

Infrastructure Solutions
scroll compressors and optimised cooling cycles means that the efciency is operate continuously and a unit provides the redundancy (in reserve).
increased thanks to their low power consumption.

Compact Measurements Example of different air-conditioning solutions with redundancy


The new Lampertz LPA series was developed to t in the smallest possible Discharging redundancy
space. Using targeted innovations, the unit footprints were reduced consid- Thermal load 1+1 2+1 3+1
erably. The units thus require even less space in the data centre.
13 kW 2 x 13 kW 3 x 7,8 kW -
17 kW 2 x 17 kW 3 x 10 kW 4 x 7,8 kW
Low Noise Levels
The low noise levels are achieved through the use of the specially-developed 25 kW 2 x 25 kW 3 x 15 kW 4 x 10 kW
fans, optional air currents and double-walled panels. Sound absorbers can 35 kW 2 x 35 kW 3 x 20 kW 4 x 13 kW
also be used for an additional noise reduction of up to 5dB(A). Prerequisite: 20 m clearance between the internal and external units

Ease of Maintenance
The consideration of such details leads to a reduction in operation and
maintenance costs, an increase in reliability and a service-friendly design.
For example, all important parts belonging to the air-conditioner are
installed in a separate area and can be easily accessed by simply opening its
door at the front.

Comprehensive Model Range


The new Lampertz LPA series is ava ilable in several versions with different
air guidance systems : upow, downow and displacement. All types of
cooling are possible: direct vaporiser, cold water, free cooler, dual uid and
constant (for particularly precise temperature and moisture control).

The following are included as standard:


Highly-efcient fans with 7 speed levels
External pressing of up to 200 Pa
Double-shelled panels, class A1 insulation
Scroll compressors
Filter class G4 (EU4)
CW devices: Speed control with constant pressure loss
W/H devices: Condensation pressure control for constant pressure loss
Micropressor control

Advantages:
Eurovent, CE, ISO 9001, VDI 6022 certication
Free-running radial fan with backward-curved blades, 7 speed levels
High-efciency fan: up to 30% less power consumption compared to
conventional fans
High, sensitive cooling capacity with a low space requirement tanks to
generously dimensioned heat exchangers
Easy connection to customers own building control systems

Lampertz 55
Floor-standing air conditioning units

Various types of n+1 redundancy:

We point out ways to save energy, e.g. with different types of redundancy

1+1 + 2+1 +
100% cooling capacity 100% redundancy 50% + 50% cooling capacity 50% redundancy
Continuous operation Continuous operation
The redundant air conditioning units operate alternately.

Energy saving redundant operation


2 in operation, 1 on standby 3 in reduced operation

3 kW 3 kW 3 kW 0,9 kW 0,9 kW 0,9 kW

6 kW power 2,7 kW power


consumption of all fans consumption of all fans
@ 44,000 m/h @ 44,000 m/h
Through continuous redundancy, a further 50 % can be
saved in addition to the design savings on the fan side I.e. total savings approx. 75%!
(approx. 50% compared to conventional units).

Technical details:

Radial fan Fan with free running impeller Display control unit Display / control unit
All units are equipped with free This unit enables the conguration
running impellers: The new genera- and graphic display of the stored
tion with specially shaped blades, data of all connected units (up to
developed for use in air-conditioning 8 or 16 microfaces in the LAN).
cabinets, have a very high mechani-
cal efciency. In addition, the noise System windows and
emission of the blade is reduced to self-explanatory menu
a minimum. These fans have been Online Help & Setup Wizard
developed so that there is no risk of Automated setup &
motor overload. commissioning

Please do not hesitate to contact us for a quotation for your individual conguration.

56 Lampertz
Floor-standing air conditioning units

IT cooling
Room-based systems

Closed circuit air conditioning system - cold water based

Air handling units for data centre air conditioning via raised ooring
Output range 23 - 118 kW with cold water
Output range 18 - 54 kW with refrigerant
Option:
Humidication
Heating
Humidication + heating

Infrastructure Solutions
We ensure the right atmosphere for you
Water
Wasser
With our energy saving units,
Temperatur
Temperature

10 g/kg

12 g/kg

14 g/kg

16 g/kg

18 g/kg

20 g/kg
0 g/kg

2 g/kg

4 g/kg

6 g/kg

8 g/kg

you can score points 1.05 kg / m3


5% 10% 15% 20% 30%
40%
already choosing the suitable model. 40
50%

35
We will convince you that we have the right solution. 60%

We provide you with air-conditioning solutions which are: 70%


Cold-water based 30
80%
1.10 kg / m3
Direct evaporator systems 90%
Indirect free cooling 25 100%

Direct free cooling

Rel. Feuchte
and use of alternative energies, e.g. geothermal, CHP, etc.
20
ie
alp
th
En

15
60
kJ
1.1

/ kg
5k
g/
m
3

10

5
40
kJ
/ kg
1.2
0k
g/

0
m
3

20

-5
kJ
/ kg
1.2
5k

-10
g/
m
3

0k
J/

-15
kg

Mollier h x diagram for humid


Mollier-h-x-Diagramm air - pressure
fr feuchte 0.9500.950
Luft - Druck bar (537.000 m/m
bar (537.000 10.000 C /C80.000
/ 10.000 %%
/ 80.000 rF)rF)

Lampertz 57
Liquid Cooling Package

LCP Liquid Cooling Package


Modern cooling units with a favourable efciency and perfect interface
technology present completely new prospects for the adequate cooling of
electronic components. This is the crucial point when it comes to IT-availabil-
ity. With its increasing heat capacities, the new air-conditioning technology,
as supplied in the Lampertz LCP, provides investment security for the future.
High heat concentrations within data centre are cooled using rack-based
technology.

Modular, upgradable and temperature-neutral cooling concept.


Max. 12 kW cooling output, with three cooling modules possible per Cabinet 1
cooling rack.
Approx. 4 kW cooling output per cooling module at 800 m3/h air
throughput.
Optimised air routing: Cold air is blown in at the sides, so that the cold
air is evenly distributed in front of the 482.6 mm (19) level.

Technical specications:
Mounted as a cooling rack on a server rack based on TS 8, with H =
2000 mm, D = 1000 mm.
Each cooling rack can accommodate a maximum of three air/water heat
exchanger cooling modules.
Standard supply: Cooling rack equipped with one cooling module.
Individual modules upgradable to full installation via quick-release
couplings.
Control via a separate module which may be connected to the CMC-TC
for incorporation into the network (monitoring).
Condensation management: The pump in the condensate tray pumps any
condensation into the return section of the cooling circuit.
Cabinet 2
Benets:
Secure investment by further extension.
Retrotting without long downtime.
No interruption of the room climatisation. LCP

Single module (can be retrottted)

Neighbouring network cabinets can be air-conditioned


from both sides thanks to exible LCP systems.

LCP, available with one, two or three modules:

2 3

2
1 1 1

58 Lampertz
Liquid Cooling Package

LCP Liquid Cooling Package


The discharged warm air from the servers is extracted along the entire which makes no demands whatsoever on the room air-conditioning system
length of the rear area of the cabinet with the aid of redundant, powerful should there already be an air-conditioning system, the LCP systems will
fans and then passed on via air and water heat exchangers located on the not place any additional burden on it. In addition, the LCP is built up in
side to a cold-water network or a cooling unit. Then, the air cooled using the a modular fashion using a maximum of 3 LW/WT units meaning that the
air/water heat exchanger is blown at approximately 22C to 25C (can be cooling performance can also be retrotted in steps of 4KW, depending on
adjusted in the range of between 10C and 55C) in continual circulation your requirements (at a water feed temperature of 15C, volume current of
in front of the 19-level. This makes the LCP a closed air (cooling) system 15 min/module).

Infrastructure Solutions
The LCP comprises the rack, air/water heat exchanger and redundant fans.

Enclosure + 1 module Enclosure + 1 module Individual module for 230 V / 115 V


Order no. SK 3301.230 3301.210 3301.250
Rated operating voltage 230V, 50/60 Hz 115V, 50/60 Hz 230 V/115 V, 50/60 Hz
Dimensions in mm
Width 300 250
Height 2000 550
Depth 1000 950
Useful cooling output
at 15C water inlet, 15l/min, 20C cool air 4000 W / 3500 W 4000 W / 3500 W

Rated current max. 1,8 A


Pre-fuse T 5,0 A
Cooling medium Water
Water inlet temperature +5C to +30C
Permissible operating pressure p. max. 2 to 8 bar
Temperature range +5C to +40C
Protection category to EN 60 529/10.91 IP 54
Duty cycle 100 %
Type of connection Current: connection cable with earthing-pin plug
Water: quick-release fastener
Weight max. 160 kg ca. 25 kg
Colour RAL 7035
Air through put of fans max. 2400 / 2100 m/h max. 800 / 700 m/h
Temperature control Electonically controlled magnetic valve and
4-way fan control

If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

Lampertz 59
Recooling Systems

Recooling systems
Recooling systems ensure centralised, efcient cooling and provision of the
cooling medium (generally water). For example, all cooling tasks on a system
or machine can be solved via a single pipeline system. Spatial separation
between cooling production and process cooling can be achieved with
recooling systems.

1 Recooling system
Emergency water
2 LCP (Liquid Cooling Package) supply
Water/water-
3 LPA oor-mounted air-conditioning system heat exchanger

4 Server-racks

Free
Cooling 1

Heat
use

Control/
distribution

In oor-standing enclosure, cooling output 2100 to 7700 W

4
2
4

In oor-standing enclosure, cooling Output 10000 to 25200 W

Technical data:
Floating contact for collective fault signal Modular climate control concepts to your specic requirements! Rittal solves the
Level monitor problem of climate control for high heat losses per rack with liquid cooling compo-
Temperature application range -20 C to +45 C nents. Extremely high heat loads are dissipated from the enclosures, IT and server
Automatic bypass valve racks via air/water- heat exchangers. Additionally, data centres may be extended in a
Return valve in supply area temperature-neutral way.

Recooling systems
Order no. Cooling capacity Dimensions Weight
W/H/D mm kg
3300.900 4,8 kW 595/1180/800 143
3300.901 8,2 kW 615/1178/1160 215
3300.902 12,0 kW 750/1600/880 400

If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

60 Lampertz
Recooling Systems

IT Cooling - efciency increase through aisle containment

Standard series solution for 1200 mm aisle width and 2000 mm


rack height
Consisting of door system and ceiling elements
Individually adapted systems based on the above series, modied,
planned and installed by us.

The right concept for every task.

Application range
Cold-aisle containment - hot-aisle containment

Basic solutions

Infrastructure Solutions
Closed circuit air conditioning system (UKS)
with aisle containment

LCP Extend

LCP Inline
with aisle containment

LCP Standard / LCP Smart

LCP Plus

LCP T3 + fully redundant

Low Average High Heat load of


heat density heat density heat density the server cabinet

Depending on the place in which it is used, correctly designed and installed Types N Two-leaf door
containment can make a large contribution to energy efciency. N Sliding door

Advantages N Homogeneous air distribution in front of the servers Depending on the requirements, either cold aisle or hot aisle containment
N as a result the blow-in temperature in front of the servers can be useful. But a combination is also feasible. Sealing within the racks
can be raised signicantly ensures correct functioning.
N if necessary, the air quantity can be designed to be
lower - hardly any more mixed air

Lampertz 61
Power Supply

Lampertz Power Supply Concepts


UPS equipment Without limitiation. The energy concepts offered by Lampertz are your secu-
Lampertz, as the complete supplier of physical IT security solutions, is offer- rity guarantee so that your emergency does not turn into a disaster.
ing its own UPS system solutions. This means that an additional infrastruc-
ture is now integrated with proven Lampertz experience. Fuel cell
A reliable power supply is a core element of IT security. Fuel cell technology
Emergency power energy concepts counts as the trend-setting technology for providing IT systems with an
There are situations in which you simply cannot afford to have a power failure. emergency power supply.
During such times, you must be able to rely on your emergency power supply.

Lampertz UPS systems


An uninterrupted power supply (UPS) is needed if a high level of availability PS classication in accordance with EN 50091-3 and EN 62040-3
is a must for a particular data centre and the company cannot afford to have VFI (Voltage and Frequency Independent)
any downtimes. The most important distinguishing feature of UPS systems is All Lampertz UPS systems full the highest quality class 1 VFI-SS-111.
their mode of operation in accordance with EN 50091-3, IEC 62040-3:1999
and VDE 0558 section 530.The aim of this kind of classication is to allow In addition to the range of products available, the UPS units now also make
manufacturer data to be compared. Lampertz offers solutions for UPS redundant systems possible for extending existing data centres. Using
systems. This means that an additional infrastructure is now integrated with battery packs, the UPS guarantees the necessary power supply for service,
proven Lampertz experience. storage and network units, should there be a disruption in power.

UPS input UPS output

Sinusoidal output voltage for a UPS with


VFI-SS-111 classication.

62 Lampertz
UPS Systems

The double-converter technology protects the IT infrastructure against hard- UPS management software enables the automated remote management
ware damage, loss of data and operational downtimes created by power of both individual and networked computers. The software permits an
disruptions, voltage peaks or similar malfunctions. The terminal equipment extensive and exible user conguration which creates an intelligent system
is supplied with a constant quality of energy generated by batteries / trans- to allow measures to be taken independently in uncontrolled emergency
formers. The software included as standard in the scope of supply allows situations such as power failure, re and break-ins.
both the operating status to be displayed and systems and servers to be
shut down fully automatically. Possible dened actions to events could be the sending of messages per
e-mail, text and network messaging, or the execution of commands for
The power is continually supplied via the UPS even during normal opera- shutting down servers while saving and closing different applications. RC-
tion. The battery is simultaneously recharged in the mains. Should there be CMD (Remote Console Command) is responsible for the reliable execution
a power failure or malfunction, the power inverter is supplied with power of commands and the dispatch of messages to remote computers. This
from the rechargeable battery and the consumer is supplied with power RCCMD licence is required for each server and must be ordered separately.
without a change-over time, as in the case with line-interactive UPS systems.
The UPS protects against power malfunctions such as voltage peeks, over 19-plug-in systems
and undervoltage, and noise. PMC 12 (Power Modular Concept), single phase

Power Malfunctions
Description Cause Impact

Infrastructure Solutions
Undervoltage Drop in voltage
causes 87% Many units start Reduced service life
of all power malfunctions simultaneously (high power of the hardware
consumption in the start-up phase)

Complete power failure Power network overload, storms Memory and data
faults

Overvoltage Short impulses,


voltage rises through power supply system, Lightening, accidents, Grave
network or telephone lines power supply restarted hardware damage,
after failure complete loss of data

Short overvoltage Any high-performance units Reduction in the service life


at least 1/120 second in the vacinity are turned off of the hardware

Noise / interference
The sinus curve of the Includes rectiers in power Impact on
alternating current is units with non-linear magnetic data carriers, when
interrupted power consumption reading and writing
data records

Technical data:
Order no. Model Autonomous time Dimensions Protection type Cooling Colour Space require-
(WxHxD) ment m
110011749614 10 kVA 15 min. 335 x 809 x 767 IP 20 Fan assisted RAL 9011 0,25
110011749615 20 kVA 15 min. 450 x1250 x 830 IP 20 Fan assisted RAL 9011 0,37
110011749616 30 kVA 15 min. 450 x1250 x 830 IP 20 Fan assisted RAL 9011 0,37
110011749617 40 kVA 15 min. 450 x1250 x 830 IP 20 Fan assisted RAL 9011 0,37

Options:
Order no.
110019911196 Freight costs (all models) Transfer to ground-oor location
110019911197 Start-up and instruction (all models)
110011749671 SNMP Adapter (for settings via network: telephone network, web browser or hyperterminal)
110011749672 RCCMD lincence

Lampertz 63
UPS Systems

UPS systems PMC-Power Modular Concept, single-phase


The UPS is distinguished by the use of double-conversion technology. DK 7857.430, DK 7857.431, DK 7857.432 Supply includes:
Double-conversion technology provides the basis for an optimum supply Single-phase UPS systems in double-conversion technology (VFI-SS 111)
voltage to all connected loads. This means that the Rittal PMC 12 UPS is with internal hot swap compatible batteries,USB and serial interface.
ideallly suited to all applications in the IT environment, as well as for all
other requirements such as medical technology, automation technology, DK 7857.433, DK 7857.434 Supply includes:
plant control etc. A scalable autonomy of up to 2 h at 100 % load ensures a Single-phase UPS systems in double-conversion technology (VFI-SS 111),
broad spectrum of applications. USB and serial interface.

UPS for 482.6 mm (19) racks or as oor-standing


UPS with integral battery UPS control unit
enclosures
Model No. DK 7857.430 7857.431 7857.432 7857.433 7857.434
VA 1000 2000 3000 4500 6000
Power Watts 700 1400 2100 3150 4200
Max. heat loss (W) 105 210 252 315 420
Rated voltage 230 V (160 288 V)
Input Frequency 50/60 Hz 5 %
Power factor > 0.99 with linear load
Voltage 230 V < p1 % (200/208/220/230/240 V adjustable)
Frequency, synchronised 1 Hz
Frequency, asynchronous p0.1 % p0.1 % p0.1 % p0.2 % p0.2 %
Crest factor 3:1
Output Non-linear distortion <7% <7% <7% <6% <6%
Wave shape <3%
Operating ratio, AC mode 85 % 85 % 88 % 90 % 90 %
Operating ratio, battery mode 83 % 83 % 85 % 87 % 87 %
Power factor 0.7
5 years EUROBAT 5 years EUROBAT 5 years EUROBAT 5 years EUROBAT 5 years EUROBAT
Battery
Autonomy at 100 % load > 7 min > 7 min > 5 min > 12 min > 8 min
105 % continuous
Overload 120 % 30 sec 30 sec 30 sec 160 sec 160 sec
150 % 10 sec 10 sec 10 sec 160 sec 160 sec
Interface 1 x USB, 1 x RS-232
SNMP Optional SNMP card DK 7857.420
Communication
Operating systems supported Windows, Unix, Linux, OS/2, Novell, Apple; RCCMD shutdown licence DK 7857.421
Emergency Power Off (EPO) O
Width mm 440
Height mm 88
Depth mm 405 650 650 660 660
Mechanics Weight kg 15.7 29.4 29.7 24 24
Input connection 230 V 10 A C14 10 A C20 Compact connector Compact connector
4 x 10 A, C13,
Output connection 230 V 6 x 10 A, C13, 2 units switched 2 units switched, Compact connector Compact connector
1 x 16 A, C19
Humidity 0 90 %, non-condensing
Operating
Noise level 50 db (A)
environment
Safety IEC/EN 62 040-1, EN 60 950-1
Power IEC/EN 62 040-3
Standards and
EMC EN 50 091-2/EN 62 040-2 class A, EN 61 000-4-2/-3/-4/-6-8/-11, EN 61 000-3-2/-3
certications
Labelling CE, FCC, cUL

64 Lampertz
UPS Systems

UPS systems PMC-Power Modular Concept


Rittal Power Modular Concept PMC 12 Batteries hot swap compatible, may be exchanged from the front
Double conversion technology VFI-SS 111 Integral batteries with 1 3 kVA
For use as a rack or oorstanding enclosure with 90 rotating LCD display External batteries with 4.5 kVA and 6 kVA
2 HU high Parallel switching 4.5 kVA and 6 kVA UPS up to 12 kVA N+1 redundant
Serial/USB interface and Emergency Power Off (EPO) contact Optional SNMP card

Block diagram parallel redundant UPS DK 7857.433/.434

Infrastructure Solutions
Source Load

Power
UPS, single-phase, output range 1 12 kVA N+1 redundant
Accessories for Model No. DK 7857.430 7857.431 7857.432 7857.433 7857.434
External bypass1) 6) 7857.439 7857.440 7857.441
Battery pack2) 7857.435 7857.436 7857.437 7857.442 7857.442
Parallel Hot Swap Chassis for 2 UPS systems3) 7857.443 7857.443
Parallel Hot Swap Chassis for 3 UPS systems3) 7857.444 7857.444
PDM for PMC 124) 7857.445
SNMP card 7857.420 7857.420 7857.420 7857.420 7857.420
RCCMD shutdown licence 7857.421 7857.421 7857.421 7857.421 7857.421
Connection cable for 4.5 and 6 KVA5) 7857.446 7857.446
Connection cable, UPS, single-phase 7856.027 7856.027
Connection cable, UPS, single-phase, C20 7856.030
Slide rail, depth-variable 7063.883 7063.883 7063.883 7063.883 7063.883
5) Not required when using the Hot Swap Chassis. 6) Extended delivery times.

1) External bypass:
The external bypass allows the UPS to be
swapped with the system operational.
3) Parallel Hot Swap Chassis:
2) Autonomy (min) at 100 % load: The parallel hot swap chassis for the 4.5 kVA and
6 kVA module allows up to 3 UPS systems to be
In supplied Battery packs connected together. This can be used to boost
UPS type output and to achieve N+1 redundancy. An exter-
state 1 2 3 nal bypass is additionally integrated into the
Parallel Hot Swap Chassis.
1 kVA 7 min 1:09 h 2:13 h
4) PDM for PMC 12:
2 kVA 7 min 34 min 1:09 h Single-phase power distribution for use with the
3 kVA 5 min 30 min 1:02 h Parallel Hot Swap Chassis DK 7857.444.
The PDM offers the opportunity of connecting two
4.5 kVA 12 min 31 min 54 min single-phase 32 A CEE connectors and four
EN 60 320 C19 16 A connectors. All outputs have
6 kVA 8 min 20 min 36 min pre-fuses.

Lampertz 65
Emergency Power Energy Concepts

Emergency Power Energy Concepts


Availability per year Downtime per year
99% 3.6 days
99,9 % 8.7 hours
99,99% 53 minutes
99,999% 5.3 minutes
A downtime, whether planned or unexpected, means that your system is unavailable!

Power supply and distribution Emergency power system


The size of the distribution system is planned for each individual customer The integration of an emergency power system is, in addition to a UPS
based on the electrical power and the components integrated in the data system, one of the most important modules for a redundant power supply.
centre. During the planning stage, any redundant network structures, UPS Should the local power supply or transformer unit fail, the power supply is
systems or the inclusion of emergency power systems are taken into consid- taken over by the emergency power system. The planning, sizing and set-up
eration in accordance the project in hand. work is performed by Lampertz while taking into account the building regu-
lations and technical specications and the equipment is supplied ready for
operation. Emergency power systems can be implemented in plant rooms
especially provided for this purpose or as computer solutions to be installed
externally.

Cabling
The cabling for the components installed in the data centre such as air-
conditioning technology, re-alarm and extinguishing system, UPS system
and the electrication of the server and network cabinets is installed in a
competent manner.

Depending on the application, Lampertz can also perform the electrical


installation in the direct environment (e.g., the plant rooms).

66 Lampertz
Emergency Power Energy Concepts

Example of an application:
The graphics show a network structure for a high degree of power availability Here the servers, the sensitive power consumers (network A + network B), are
(99.99%). In addition to the public power supply, a redundant power supply in the supplied with UPS systems via a redundant power supply.
form of an emergency power supply system is provided.
During maintenance work or repair measures on network A/B subdistributors or UPS
Should the public power supply fail, the emergency power supply takes over within a systems, the data centre operation does not need to be interrupted. The consumption
few seconds for the duration of the tank reserve. The momentary failure of the power points not supplied with power by the UPS, such as the air-conditioning technology,
supply during the emergency power systems start-up procedure is taken on by the are in this case supplied directly from the unsecured rail.
UPS systems. The UPS system overriding time is set at around 10 minutes.

Energy concept diagram


with UPS (uninterrupted power supply)
and emergency power system

Power supply by
power
supply industry

Infrastructure Solutions
Transformer

Unsecured distribution,
Emergency power system, Low voltage e.g., air-conditioning and
e.g., diesel generator main distributor ventilation technology

Main distributor

UPS External UPS External


network A manual switching network B manual switching

Secured subdistributor Secured subdistributor


for server technology, for server technology,
network A network B

Feeder, Feeder,
server technology 1 server technology 2
network A network B

Lampertz 67
Cogeneration (CHP) Units

Cogeneration (CHP) Units Functionality


Wrz Cogeneration (CHP) Units are powered by plant oils. Hence, they Wrz Cogeneration (CHP) Units work according to the principle of combined
provide independence from fossil fuels with maximum supply reliability. heat and power generation. They generate electricity whilst at the same time
Decentralised technology offers independence from centrally-supplied elec- providing a heating or cooling system. Thats how they achieve an efciency
tricity and xed prices. Reductions in primary energy consumption permit rating of up to 86%.
lower fuel consumption, thus optimising your carbon balance/footprint.
Efcient energy generation
Reduced primary energy consumption
CO2 neutral

Technology Advantages:
Wrz Cogeneration (Combined Heat and Power or CHP) Units are exclusi- Sustainable raw materials
vely deve-loped and manufactured by a team of experienced specialists at Versatility
our German factory in Wilnsdorf. Strict quality controls throughout the entire Modication of new fuels
manufacturing process guarantee a long and reliable service life. Power
ratings range from 90 to 680 kW. Where greater quantities of energy are to The following plant oils are in use today to operate Wrz Cogeneration (CHP) Units:
be generated, we install our units in modular layout. Palm oil*
Advantages: Soya oil*
Quality control system Rape seed oil*
Long service life Biodiesel
Reliability * conforming to RW-norm

A secure future Availability


The adaptation of these new fuels equips us today to meet tomorrows Long service intervals for both engines and equipment result in minimal
developments. If required, Wrz Oil can also take on your fuel procurement downtimes. And with the Wrz Full Service Contract, youll achieve a fantas-
needs. tic 85% availability with a guaranteed 7,200 hours per year. Advantages:
85% guaranteed availability
Long maintenance intervals
Minimal downtimes

68 Lampertz
Fuel Cells

Fuel cells for data centres


Based on a TS 8 server rack, the concept offers a scalable output from 10 to In general two elds of application are possible:
200 kW, the output being matched to the actual UPS requirements. As an additional redundancy augmenting batteries and generators, they
provide an extra safeguard for extremely important applications or data.
Ideal for critical IT-applications requiring high-availability, where reliable, As an emergency power supply, this technology opens up the opportunity
uninterrup-ted operation must be ensured, fuel cell technology will represent of dispensing with diesel generators and signicantly reducing the size
a convincing alternative in the future. of battery-based back-up systems.

Infrastructure Solutions

System structure User-friendly control


Taking as an example a 60 kW system in a TS 8 server rack (W x H x D Simple operation and monitoring via CMC-TC and an open platform for
= 600 x 2000 x 1000 mm), we show below the components which are facility-management protocols: S-bus, Probus, Modbus, MPI, EIB, LON,
combined with Rittal system-integration know-how into a back-up solution Bac-Net, GENIbus.
providing high-availability.
DC/DC converter and climate control
The fuel cells A plate-type heat exchanger in combination with a recooler extracts the
The heart of the system - compact high-performance power units requiring heat from the server rack.
minimum space: 30 kW PEM fuel cells on 6 U, 60 kW on 12 U.

Lampertz 69
Early Fire Detection

Early Fire Detection system for room applications


A re must be safely detected while still in its ignition phase if effec- and alarm procedure. Early re detection enables maximum limitation of
tive countermeasures are to immediately introduced. The highly-sensitive any damage due to the fact that countermeasures take hold much earlier.
Lampertz early re detection systems work on the basis of active optical Personal protection, securing the availability of important technical systems
smoke extraction systems and guarantee the earliest possible re detection and the protection or irretrievable values are all guaranteed.

Examples of evaluation units (depending on the existing or optional re-alarm and extinguishing system)

Novec extinguishing gas Universal Nitrogen extinguishing gas

Design examples:
The smoke extraction system essentially comprises two parts: the suction tion systems do not have to wait until the smoke rises, but instead actively
pipe which can be branched off as much as possible and with individual extract it while simultaneously possessing a huge detection sensitivity, they
suction openings and the detection chamber. This contains a laser detector, react to igniting res much quicker and more sensitively than conventional
a fan and the electronic evaluation switch. The fan sucks the ambient air solutions. An additional advantage is that the suction pipes can be installed
via the suction points and guides it to the laser detector. Smoke particles out of view in the room cladding and do not detract from the overall view of
are registered there immediately. If the limit value is exceeded, a central the room.
re-alarm system is automatically triggered. Four limit values can be set, Depending on the extinguishing media used by the customer, there are dif-
depending on the customers needs. Due to the fact that the smoke extrac- ferent solutions available for the central re-alarm system and the early re
detection system.

Air ow Evaluation unit

Example of room monitoring:

Air ow

Technical data:
Order no. Dimension Weight Network connection
W/H/D in mm in kg
110011749642 Early re detection using extinguishing system with Novec 320/228/115 3.4 RS485
110011749643 Universal early re detection system 225/225/85 1.9 RS232
110011749644 Early re detection using extinguishing system with nitrogen 546/267/71 6.1 RS232

70 Lampertz
DETection-ACtive

DETection-ACtive re-alarm and extinguishing systems for room and rack applications
No re without oxygen Gas extinguishing technology basically offers the following advantages:
For a re to ignite and persist, three ingredients must be present: fuel, heat Extinguishing without residue
and oxygen. If one of these factors is taken away from the re, it will be Room, object and equipment protection without water damage
extinguished. Since, for IT-availability reasons, water may not be used for Quick resumption of the processes after the extinguishing procedure
extinguishing purposes, the room is ooded with extinguishing gas so that Fire damage is limited to the system component responsible for causing it
the re can be extinguished quickly and without residue. Extinguishing gas cannot conduct electrically or toxically. Thus, there is no
danger to persons through electrical equipment and no danger of short
circuiting during and after the extinguishing process

Infrastructure Solutions
System cabinet for rack extinguishing

Lampertz predominantly works with Novec 1230 extinguishing gas.

Method of operation:
Once a re has been detected by the automatic alarm systems or if the
manual alarm has been triggered, the alarm equipment are triggered via
the central re-alarm system. Once a specic delay time (10 seconds) has
elapsed, the bottle containing the extinguishing agent is opened electrically
and the extinguishing gas ows via extinguishing nozzles into the room.

System cabinet for room extinguishing

Compact extinguishing system (room) Compact extinguishing system (rack)


The compact extinguishing system with Novec 1230 extinguishing agent Extinguishing nozzle
unites all of the components in a small space. Control centre smoke extraction system
Electrically-triggered valve
Extinguishing nozzle Extinguishing media container with Novec TM 1230
Control centre smoke extraction system Pre-assembled connection set
Electrically-triggered valve Up to 24 racks
Extinguishing media container with Novec TM 1230
up to 84 m

Fire-alarm and extinguishing system, Novec 1230 extinguishing gas


Order no. Operating Flooding Available Dimensions (mm)
pressure ( +/- 5%) time extinguishing gas (W/H/D)
container sizes
110011749645 42.0 bar < 10 sec. 40 or 80 l 300 x 2000 x 1000
300 x 2000 x 1000

Lampertz 71
Early Fire Detection System

Lampertz Early Fire Detection EFD Plus


In addition to the complete re detection and extinguishing system, there is In the inside of the EFD housing, a fan generates a vacuum through which
now an early re detection system for the 19- rack. air is sucked in from the surveillance area via a pipe system containing
several small boreholes. Internal sensors are monitoring the extracted air for
The EFD is a quick, effective and cost-efcient way of securing company thermal additives which occur during the pyrolysis phase. In this manner the
processes and thus preventing damage occurring. danger of re can be detected before a smouldering re can develop. If the
threshold value is exceeded, then the system will set off an alarm.

EFD Plus - technical data EFD Plus order suggestions


Width: 19-slide-in module, 447 mm Order no. Designation
Height: 1 HU, 44 mm 110010576286 EFD Plus, 1 HU
Depth: 500 mm
Protection type: IP20 110010576281 EFD Plus Kit, 1 HU
Ambient out temperature: +10C to +35C Kit includes: 1 Piece 110010576286,
Emergency generating unit: 4 hours 1 Piece 110010576282,
Sensitivity: 0.5% light cloudiness / m 2 PU 7320.814,
Storage temperature: -10C to +50C 1 PU 7063.883
Power supply: 230/115V, 50/60 Hz See Page 65 for a description of accessories
Uninterrupted emergency
power supply: max. 4 hours
Contact rating: max. 30 VDC / 1 A Simple Conduit Connection
Display: LCD display with plain text information
System
Connections: Four relay contacts, each with one potential-free
The conduit connection system is
alarm change-over contact (RJ 12 plug) for
CMC-TC connection.
required to permanently draw air
into the DET-AC system. By this
way, a re can already be detected
in its initial stage, preventing grea-
ter damage occurring.

72 Lampertz
EFD Plus

Advantages of EFD Plus: Typical areas of application are:


Smoke extraction system for active early re detection Data centres
Detection of any cracks or blockages in the connected pipe system Information and communication centres
Optical status display on the housing front for operation, alarm Electronic and electrical equipment
and malfunction

Smoke concentration

Fire progression curve and sensitivities

Pyrolysis phase Smouldering re Open re


detection
Invisible smoke aerosols Visible

Infrastructure Solutions
t/time

Early re detection system


Early re detection system
Fire detection system

Smoke alarms

Lampertz
Early Fire Detection system

1 3 Sensitivity in % light cloudiness / m

Accessories for EFD Plus, DET-AC Plus (Page 66) and DET-AC Plus Slave (Page 67)
Order no. Designation
110010576282 Pipe kit
for continuous air intake
7320.814 Cable with 2 RJ 12 plugs
Alarm forwarding to the CMC-TC unit (pack of 2)
7063.883 Depth variable runner
(pack of 2)
7320.530 CMC-TC input sensors
(pack of 2)

Lampertz 73
DET-AC Plus

Comprehensive business continuity solution for your IT


Compact smoke extraction system with active Novec1230 extinguishing for In the initial re phase (pyrolysis phase), the smallest smoke particles can
network and server cabinets. The environmentally-friendly extinguishing gas, be detected by the active smoke extraction system. Even in systems with a
which is not hazardous to humans, is stored in a small, light container. This high air-conditioning capacity output, there is enough time to pass on an
innovation allows gas storage on the limited space of one height unit, only optically signal via the LCD dis-play on the front of the housing. This hap-
without the need for large gas cylinders. pens through voltage-free contacts into the central building control system,
the central re alarm system, or the Rittal CMC-TC. A four-hour emergency
power supply is supplied as standard.

Flexible Installation
Only one height unit is needed in
a rack. The installation position is
not specied but ideally the DET-AC
should be installed at eye level.

DET-AC Plus - technical data DET-AC Plus order suggestions


Width: 19-slide-in module, 447 mm Order no. Designation
Height: 1 HU, 44 mm 110010576285 DET-AC Plus, 1 HU
Depth: 768 mm
Protection type: IP20 110010576280 DET-AC Plus Kit, 1 HU
Ambient temperature: +10C to +35C Kit includes: 1 Piece 110010576285,
Storage temperature: -10C to +50C 1 Piece 110010576282,
Power supply: 230/115V, 50/60 Hz 1 PU 7063.883,
Uninterrupted emergency 2 PU 7320.814,
power supply: max. 4 hours 1 PU 7320.530
Contact rating: (alarm, malfunction, switch-off): max. 30 VDC / 1 A
See Page 65 for a description of accessories
Protection volumes: max. 3.0 m
Sensors: 2 sensors optical sensor, sensitive optical sensor Alarm monitoring
high sensitive, with 2 levels pre-alarm, main
By transferring the signal of the pre-alarm, main alarm and failure to a cen-
alarm
tral building control system or network, short reaction times can be granted.
Display: LCD display with plain text information
Extinguishing gas container: Aluminium
An automatic system shut-down can be achieved through CMC-TC con-
Extinguishing gas: environmentally-friendly Novec 1230 nection and switchable power outlet strips (power system module). Thereby
Quantity of extinguishing damage can be prevented. The DET-AC Plus is automatically detected via
gas: 3,200 g, rellable a connected CMC-TC. With it, alarms can be passed on via e-mail or even
Door contact monitoring system to secure activation of re extinguishing system to a mobile phone. If intervention is not possible (e.g. on public holidays or
(door opened extinguisher control blocked) weekends), the DET-AC Plus extinguishes automatically.
Networking of several DET-AC Plus devices possible
Not a hazardous material, applicable internationally

74 Lampertz
DET-AC Plus / Slave

DET-AC Plus Slave


The DET-AC Plus Slave system is used to extinguish several network cabinets Air is continuously sucked-in (detection) from all cabinets through the
or security safes that have been installed next to each other. The slave master unit (DET-AC Plus or EFD). Up to four slave units can be connected
system always works in conjunction with the DET-AC Plus system (which up to a master unit. The extinguishing gas is stored in the slave unit.
already contains the extinguishing gas for three square metres) or with the Extinguishing is triggered by the master unit.
EFD Plus system (no extinguishing gas storage).

Infrastructure Solutions
DET-AC Plus Slave - technical data DET-AC Plus Slave order suggestions
Width: 19-slide-in module, 447 mm Order no. Designation
Height: 1 HU, 44 mm 110010576287 DET-AC Plus Slave, 1 HU
Depth: Housing: 540 mm / Total length 570 mm
Protection type: IP20 110010576283 DET-AC Plus Slave Kit, 1 HU
Ambient temperature: +10C to +35C Kit includes: 1 Piece 110010576287,
Storage temperature: -10C to +50C 1 Piece 110010576282,
Power supply: 230/115V, 50/60 Hz 1 PU 7063.883,
Uninterrupted emergency 2 PU 7320.814
power supply: max. 4 hours See Page 65 for a description of accessories
Contact rating: (alarm, malfunction, switch-off): max. 30 VDC / 1 A
Protection volumes: max. 3,0 m within air-tight cabinets
Display: LCD display with plain text information
Input voltage: 24 VDC +/- 10 %
Closed-circuit current
consumption: 30 mA
Release current: 950 mA
Extinguishing gas container: Aluminium
Extinguishing gas: environmentally-friendly Novec 1230
Quantity of extinguishing
gas: 3,200 g
Door contact monitoring system to secure activation of re extinguishing system
(door opened extinguisher control blocked)
Connections: Four relay contacts, each with one potential-free
alarm change-over contact
Not a hazardous material, applicable internationally

Lampertz 75
Network Cabinets

Lampertz network cabinets and equipment


Enclosure all your computer equipment, from the monitor, computer system,
printer and keyboard to the mouse, becomes childs play with Rittals PC
enclosure systems. The result is perfect protection from humidity and dirt,
temperature uctuations and unauthorised access. What is more, when it
comes to ergonomics, design and accessory diversity, these systems will
exceed your expectations.

76 Lampertz
TS 8 Network Cabinet

Network cabinet TS 8 and interior equipment


An ingenious symmetrical concept with baying on all sides. With two levels,
the frame section affords innite assembly diversity. Fully depth-variable
interior installation creates exibility for various installed equipment. Fast
assembly by simply locating and securing.

Order no. 19-Rack Dimensions (H x W x D)


Supply includes: Rack with 4 pieces of 19-mounting angles
(L-shaped) and 3 sets of depth stays TS 8
Mounting angles L-shaped
7821.730 42 HU 2000 x 600 x 1000 mm
7821.779 / 7821.770 42 HU 2000 x 800 x 1000 mm
110011752496 47 HU 2200 x 600 x 1000 mm
7821.879 / 7821.870 47 HU 2200 x 800 x 1000 mm
110011754080 Rack with 19-partial assembly

Order no. TS punched section with mounting ange Dimension


8612.000 for fastening a component shelve Fastening in 19-Rack with 1000 mm depth
to the frame

Supply includes: 4 depth stays


including assembly parts

Infrastructure Solutions
Order no. Depth variable slide rail Length / Load capacity
110011752239 exible integration of 19-components 400 - 600 / 50 kg
7063.883 600 - 800 / 80 kg

Supply includes: 2 slide rails


including assembly parts

Order no. Depth variable installation kit for 19-component shelves Length / Load capacity
7063.858 Innitely adjustable to match the 400 - 600 mm / 50 kg
7063.860 spacing between the 19-mounting levels 600 - 850 mm / 50 kg
7063.890 to combine with telescopic slides 600 - 850 mm / 50 kg

Supply includes: 2 slide rails,


including assembly parts

Order no. Telescopic slides for component shelves Comp. shelve depth / Load capa.
7081.000 Supply includes: 1 pair telescopic slides 500 mm / 50 kg
7161.000 600 mm / 50 kg
7161.700 Also required: Adapter for L-shaped mounting angles 700 mm / 50 kg
7065.000 TS 8 (Order no. 7827.300) or depth variable installation kit 500 mm / 100 kg
7066.000 for component shelves (Order no. optionally 7063.858, 600 mm / 100 kg
7066.700 7063.860, 7063.890) 700 mm / 100 kg

Order no. Component shelves for fastening to the frame Comp. shelve depth / Load capa.
7185.035 Supply includes: component shelves 500 mm / 50 kg
7186.035 including assembly parts 600 mm / 50 kg
7186.735 700 mm / 50 kg
7485.035 Also required: 500 mm / 100 kg
7486.035 TS-punched section with mounting ange as installation kit 600 mm / 100 kg
7486.735 for component shelves (Order no. 8612.090) 700 mm / 100 kg

Order no. Component shelves for 19-installation Comp. shelve depth / Load capa.
7145.035 Supply includes: Component shelve 500 mm / 50 kg
7145.635 including assembly parts 600 mm / 50 kg
7145.735 700 mm / 50 kg

Also required: Adapter for L-shaped mounting angles TS 8


(Order no. 7827.300)
or Depth variable installation kit for component shelves
(Order no. optionally 7063.858, 7063.860, 7063.890)

Lampertz 77
Power Distribution Rack

Power Distribution Rack (PDR)


The PDR comprises housing certied to VDE-standard in which the complete Power Distribution Rack to accommodate a maximum of 8 PDM
power distribution system, i.e., power supply, distribution and cabinet pro- Height 1.20 m for 4 PDMs and 2 m height for 8 PDMs
tection is already integrated. For an optimum distribution of power to corre- PDM may be retrotted whilst the system is operational
spond to your individual needs, up to 8 power distribution modules (PDMs) A maximum of 32 racks may be tted to the sub-distributor
can be installed in each housing. The possibility to provide cable-connected Fully shock-hazard protected
extensions during operation guarantees the highest level of exibility Main switch in various options: 1)
- Isolator switch
- On-load isolator
- Power circuit-breakers
- RC circuit-breaker
Low-voltage distribution up to 250 A

1)
Depending on the standards of the local power supply company note:
Observe the standards of the local power supply companies.

Supply includes:
Enclosure frame with door (without tubular door frame), rear panel, side
panels and roof plate, levelling feet including base/plinth adaptor, earthing
of all enclosure panels, busbars shock-hazard protected, main switch inte-
grated.

Order no. Power Distribution Rack Dimensions (W x H x D)


7857.310 For including up to a maximum of 8 power 800 x 1200 x 500 mm
distribution models for
low voltage distribution

Order no. Power Distribution Rack Dimensions (W x H x D)


7857.300 For including up to a maximum of 8 power 800 x 2000 x 500 mm
distribution models for
low voltage distribution
Power distribution rack for incorporating a
maximum of 8 PDMs. Max. 82 server racks Order no. Plug & Play connection cable Length
can be connected to the subdistributor
7857.190 3m
7857.180 5m
7857.150 8m
7857.140 9m

Order no. Socket elements / height Dimensions (W x H x D)


8601.800 front / 100 mm 800 x 1200 x 500 mm
8601.800 rear / 100 mm 800 x 2000 x 500 mm
8602.800 front / 200 mm 800 x 1200 x 500 mm
8602.800 rear / 200 mm 800 x 2000 x 500 mm
8601.050 side / 100 mm 800 x 1200 x 500 mm
8601.050 side / 100 mm 800 x 2000 x 500 mm
8602.050 side / 200 mm 800 x 1200 x 500 mm
1 PDR 2 PDM 8602.050 side / 200 mm 800 x 2000 x 500 mm

Certied in accordance with:

78 Lampertz
Power Distribution Module

Power Distribution Module (PDM)


The use of plug & play technology means that the PDM can be easily inte- 482,6 mm (19) Power Distribution Module mechanically locked in the rack
grated in the PDR or also be used in the normal cabinet. With the PDM, up Scalable
to 4 x 3-phase server racks (3x 400V / 16A per output) can be supplied. Including master switch, optional RC circuitbreaker
4 fused 3-phase outlets to the rack
19-Rack 3 x 230 V/16 A per outlet
For energy subdistribution of 40 kW in server and network cabinets Connected load 400 V/3 AC, max. 63 A

Supply includes: 482,6 mm (19) module, 3 HU

Infrastructure Solutions

Order no. Version model


7857.320 PDM 482.6 mm (19), 4 outlets per 10 kW
7857.350 PDM 19, 4 outlets, project-specic
7857.321 Connection cable with 32 A CEEkon connector

Certied in accordance with:

Lampertz 79
Secure network design

Secure network design in IT rooms

Apart from incalculable potential risks, regardless of whether it is in the rai- Fibre and cable breaks, faulty connectors, incomplete documentation and
sed flooring or in the network and server racks, cable clutter impairs the chaotic patch cable structures result in weakspots and incalculable potenti-
ventilation and air conditioning concept. al risks. Secure network design is based on numerous standards such as EN
50173 (structured generic cabling) or EN 50174 (Installation planning and
Most unplanned downtimes result from chaotic cable structures, unclear implementation of cabling systems).
jumpers, poor documentation and human error.
In addition, individual availability standards, which frequently exceed the
usual standards, are also taken into account in secure network design.

Consequences of inadequately passive network infrastructure:


Higher total cost of ownership (TCO)
Negative effects on the air conditioning and ventilation concept
Poor and incomplete documentation
High energy costs
Malfunctions
Unforeseeable and long downtimes
High cost and effort required for maintenance, repair
and relocation
High failure costs through to existential threat
Negative effects on the technical transmission properties

Apart from the important topics such as fire protection, air conditioning,
energy supply, safety and security engineering, disaster control procedures
and structural protective measures, an important aspect is often left out of
security concepts:

Secure network design - IT-compatible, tailor-made passive network


infrastructure, which guarantees maximum function, clarity and manageabi-
lity, security and availability.

Basic cabling concepts

Interconnection concept Crossconnect concept

Switch Patchfield Terminal Switch Patchfield Patchfield Terminal


connections connections

80 Lampertz
Secure network design

Secure network design


Protect the heart of your IT!

The precondition for secure, reliable and economic operation of an IT room


is an overall, integrated network infrastructure with complete and up-to-
date documentation. A further basic requirement is specific, efficient deplo-
yment of personnel and technical resources. These are the only ways to
achieve maximum function, maximum IT security and optimum business
management use.

Secure network design is the ideal combination of economic


efficiency, security and maximum functionality.
The objective: Apart from present day and future applications (e.g.: from 1
GB to 40 GB ethernet), the SAN structure, the switchport distributions and
mechanical relief of the switchports, we integrate the whole IT environment

Infrastructure Solutions
with your transmission requirements. Further, all dynamic factors such as
jumper cable routing, labelling, extensions and manual or automatic docu-
mentation within the data centre are also taken into account.

Secure network design means:


Maximum IT security and protection for your passive network
infrastructure
Maximum availability and function
Ability to simply and effectively plan moves to new locations
Easy integration of new equipment and extensions
Shortest response times
Secure, reliable handling due to clarity and manageability at
the distribution points
Reduction of downtimes
Reduction of costs for moves, add-ons, swaps and changes
Provision for future extensions and scalability
Investment protection
Complete documentation
Optimum transmission properties of your links due to selected
and certified product and system solutions as well as
professional installation by trained personnel

Documentation and intelligent


infrastructure management
Documentation of the physical level, the cabling infrastructure, the distribu- Advantages at a glance
tion wiring and the free port capacities are in most cases still done by Automatic information and documentation in real time
hand. This is frequently time consuming, faulty and inefficient with respect Full link information
to the resources used.As changes and extensions are often made under Maximisation of the network capacities
enormous time pressure, the documentation is often incomplete or does Easy, secure and fail-safe moves to new premises, extensions and
not reflect the current status. changes
Fast fault localisation and reduction in downtimes
The solution: A fully integrated end-to-end solution for management of the Increase in network security
physical level of crossconnect networks! Clear overview of your resources
Definition and illustration of processes
Extensive reporting functions
CAD drawings can be stored

Lampertz 81
Power System Module

Power System Module (PSM)


The ever-expanding power requirements of modern IT-infrastructures vertical support rail with 3-phase infeed. The various insert modules to sup-
demand rened solutions for power distribution inside the racks. This leads ply the active components may be snap-tted into the support rail. This can
to an associated requirement for additional sockets. The new intelligent even be done whilst the system is operational, because the support section
power distribution system from Rittal signicantly reduces cabling and is shock-hazard-protected.
assembly work. The various modules, earthing pins, IEC320 etc. may be inserted into the
support rail in any combination. This is easily achieved, even by non-electri-
The modular system facilitates basic conguration of the racks, thanks to a cians, thanks to the shock-hazard protected plug & play system.

Aktives PSM 8fach, einzeln schaltbar.

Power rail
Order no. For cabinet height in mm No. of modules Type Technical specications/benets:
7856.010 1200 4 EU-Type 3-phase construction with a maximum current of 3 x 16 A
7856.020 2000 7 EU-Type A redundant three-phase infeed with 3 x 16 A may also be added.
7856.050 1200 4 US-Type The redundant circuit is completely separate from the 3 phases of the
7856.060 2000 7 US-Type support rail.
Fitting Each plug-in module picks off a phase on the support rail, either from
Order no. For cabinet height in mm Installation type infeed A or from the redundant infeed B, depending on the direction of
7856.011 1200 for xed installation connection.
7856.012 2000 mobile, for open 19-level Modules may be retrotted whilst the system is operational.
Plug-in modules All plug-in modules are equipped with integral overcurrent protection, so
Order no. Plug-in module No. of sockets Overvoltage protect. that only the affected module is deactivated in the case of an excessively
7856.080 IEC320 6 - high current. The other modules remain operational.
7856.070 )%#  s Overvoltage protection may be integrated into the supply line.
7856.220 )%#  s Support rail may be integrated into the vertical frame section of the
7856.100 D/N L/A 4 - exRack(i) without additional equipment.
7856.090 $.,!  s
7856.120 F/B 4 -
The vertical support rail allows the slots to be used exibly across the entire
7856.110 &"  s
7856.140 USA 4 - enclosure height, and congured in a redundant manner via separate power
7856.130 53!  s infeed to the individual modules.
7856.160 UK 3 -
7856.150 5+  s Supply includes:
7856.190 CH 4 - Busbar with connection socket and operating instructions. Without cable.
7856.180 #(  s

Order no. Description Also required:


7856.170 Overvoltage protection with transfer plug Connection cables, assembly kit and plug-in modules.
7856.200 PSM active power module, 4
1)
With single overvoltage protection / Other modules upon request

Certied in accordance with:

Reg.-no. A592

82 Lampertz
Power System Module

Connection cable for the busbar system PSM

Infrastructure Solutions
PVC Connection cable, three-phase
Fully wired ready for connection with adaptor
and mains connector in two variants:
EU: IEC309 connector
US: L15-30P Nema connector
Cable length 3 m

Order no. Length in m Type


7856.025 3 EU-Type
7856.055 1) 3 US-Type

PVC Connection cable, single-phase


The PSM system is easily operated as a singlephase system as well:
CEE connector 230 V, 2P+E 16 A
Cable length 3 m
Contact protection CEE22

Order no. Length in m


7856.026 3

PVC Connection cable, UPS, single-phase


For connecting to an existing UPS:
IEC320 C14 connector (non-heating appliances)
IEC cable coupler
Cable length 3 m

Order no. Length in m


7856.027 3
1)
Delivery time on request

Certied in accordance with:

Reg.-no. A592

Lampertz 83
Floor Systems

Raised-oor Systems
The raised oor creates room for cabling and air conditioning.

Cable Guidance Systems


The cable guidance systems ensure smooth data transfer and a malfunction-
free power supply.

Example with a Lampertz logo

Raised Floors
Order no. 10m Order no. 25m Order no. 40m Description
110011749646 110011749647 110011749648 Installation double oor with PVC surface, without slotted panels
point load, 2,000 newton, height up to 300 mm
110011749649 110011749650 110011749651 Installation double oor with PVC surface, without slotted panels
point load, 2,000 newton, height from 301 to 500 mm (additional charge)
110011749652 110011749653 110011749654 Installation double oor with slotted panels
without quantity control, PVC surface (additional charge)
110011749655 110011749656 110011749657 Installation double oor with rubber surface, without slotted panels
point load, 3,000 newton, height up to 300 mm
110011749658 110011749659 110011749660 Installation double oor with rubber surface, without slotted panels
point load, 3,000 newton, height from 301 to 500 mm (additional charge)
110011749661 110011749662 110011749663 Installation double oor with slotted panels
without quantity control, rubber surface (additional charge)

Glass oor elements with logo


If required, we can provide you glass oor elements with a logo. The logo is freely selectable.

Order no. 110011749664


Floor element, glass logo, transparent

If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

84 Lampertz
Cable Guidance System

Raised-oor Systems Cable Guidance System


It is essential to take a raised-oor system as a exible oor system into Cable guidance systems are used for the proper and professional installa-
account in modern data centre and room planning. The raised-oor used tion of power and data cables in the ooring and/or in the ceiling area. They
by Lampertz offers an installation space of approx. 95% to incorporate all are made of galvanized sheet steel and are designed as either a closed or a
power and data lines. You can select from oor panels made of wooden basket cable tray. Due to their good electrical shielding (EMC) and low re
and mineral material. For increased re protection requirements, the use load, these cable management systems are preferable. The separate instal-
of mineral material is recommended. The oor panel coating is available in lation of mains power lines and weak current cables can be simply achieved
rubber or PVC, depending on the solution you require. The assembly height by installing dividing plates. It is also possible to expand the cable systems
is adapted to suit the respective technical requirements. at a later date without a great deal of effort.

Infrastructure Solutions
Advantages:
Access to the installation area at any time, at any position, without noise
and dust and without interfering in the operating procedure
Large amount of space reserved for later installations
Quick relocation of oor panels with supply units to any position
required. Thus simple adaptation to changed ofce situations
Dry construction, thus can be used immediately after installation

Raised oor, type overview

Basic material of Point load Building material Fire resistance Application areas
raised-floor panel acc. to DIN EN class class
Type 1 Panels: wooden material 3000-5000 N B2/B1 F30 IT and technical
Substructure: rooms, as well as storage
galvanized steel supports areas and manufacturing
areas for normal
applications. Ofces
for industry and
administration, banks and
insurance companies

Type 2 Panels: mineral material 3000-6000 N A2 F30 / F60 Data centres,


Substructure: laboratories, electrical
galvanized steel supports operating rooms
with increased demands
on re protection

Cable Guidance System


Order no. Article Plate thickness Length
110011749665 Cable tray 0.75 mm 3m
110011749666 Cable tray, 90 bend 0.75 mm
110011749667 Cable tray, dividing plate 0.75 mm 3m
110011749668 Basket cable tray 0.75 mm 3m
110011749669 Basket cable tray, 90 bend 0.75 mm
110011749670 Basket cable tray, dividing plate 0.75 mm 3m
Other articles from the range of cable guidance systems are available upon request.
If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

Lampertz 85
Video Surveillance

Video Surveillance Solutions


Special video cameras monitor the data centre, the access area and the
complete building using existing network technology. Lampertz protects
your corporate processes by using the newest of video technologies.

86 Lampertz
Network Cameras

Lampertz Video Surveillance Network Cameras


The Lampertz video system is designed on the basis of a digital network and IP Network
can transmit video images without the need to set up an additional physical Power over Ethernet (PoE) offers the possibility of using the existing IT
infrastructure. It uses standard IP networks such as, for example, LAN or infrastructure and thus enabling the cameras to be supplied with power via
the internet to transmit information instead or relying on expensive cabling the network cable. This way, large distances can be overridden in buildings
leading from the units, as is the case in analogue video systems. Transpar- and password-protected access is available from any position. The access
ency, control and reliability, as well as built-in intelligence and integrated possibilities can be limited to particular requirements and applications using
audio feature are only some of the advantages offered by modern network a hierarchy. PoE also offers the possibility to connect the cameras to an
cameras. There are two image sensor technologies available for cameras uninterrupted power supply (UPS) and thus guarantee their stable function.
CCD (Charged Coupled Device) and CMOS (Complementary Metal Oxide
Semiconductor). CCD sensors can offer some advantages over CMOS Network-based video monitoring also provides the following
sensors, among other things, thanks to their high light sensitivity. This allows advantages over analogue technology:
the image quality to improve during bad lighting. A direct comparison of the Higher utilisation through automatic detection of movement
M10 CMOS cameras is basically not possible due to the use of a different Greater exibility through the problem-free use of network cables
technology. If a high resolution is required in situations which have little Better performance thanks to numerous features
change in movement on the whole, then they are used. If there is a lot of Lower costs through simple installation
change in movement and the speed of movement, then CCD cameras are Digital memory administration Monitoring
put to use.

Infrastructure Solutions

87 Lampertz Lampertz 87
CMOS Cameras

CMOS 1.3 Megapixel Cameras


Functions: Supply includes:
High image quality with a resolution of 1.3 million pixels, web server, FTP cli- Housing made of glass-bre reinforced plastic, white metallic, handbook,
ent, alarm notication by e-mail, text message or telephone call, profession- assembly key (allen key), ceiling support with ball-shaped head, patch cable
ally equipped with sensors, video motion movement sensors, microphone S/FTP, yellow, 8 pole, 3 m (with EMV magnetic screen).
and loud speakers.

Order no. M10Mi secure indoor,


110011749700 Including ceiling support, single optic,
wide angle, 43 mm

Standard camera with one lens


64 MByte internal image/event memory
140 x 130 x 65 mm (WxHxD) without ceiling support

Order no. M10Di secure indoor,


110011749701 Including ceiling support, dual optic,
wide angle 43 mm, telefocus 135 mm

Dual optics offer targeted monitoring in


an adjacent area and room
64 MByte internal image/event memory
140 x 130 x 65 mm (WxHxD) without ceiling support

Order no. M10Di secure night - indoor,


110011749702 Including ceiling support, dual optic, 43 mm wide angle
Automatic change-over between day and night

Use for critical applications with not enough light

64 MByte internal image/event memory


140 x 130 x 65 mm (WxHxD) (without ceiling support)

Order no. Power supply unit


110011749703 Multi-range,
Input voltage: 100-250 V~, RJ 45 plug

The power supply unit is connected either to the ISDN or


the ethernet interface of the camera.

For supplying remote power to the camera via the


network cable (Power over Ethernet), the
network powe adapter will be additionally needed.

Order no. Network power adapter


110011749704 For single cameras,
Remote operating voltage supply
via network cable

Single PoE adapter for one camera


3 RJ 45 sockets (power supply, camera, network)

Order no. Power supply unit


110011749705 With 4 integrated network power
adapters, for connecting up to 4 cameras

PoE power supply unit for connecting up to 4 cameras

The installation of the cameras and software can be provided upon request.
Outdoor variants with weather-resistant housing are available upon request.
If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

88 Lampertz
CCD Cameras

CCD Cameras
Functions: Supply includes:
Advanced signal processing, image improvement algorithms, video compres- Power supply unit, ceiling support, rubber foot kit for table installation, short
sion technologies, high image rates. Progressive image scanning leading installation instructions, operator manual, licence for MPEG-4 coding and
to a reduction in blurred movement and clearer pictures as is the case in decoding.
analog videos with interlaced scanning.

Order no. 210, network camera,


110011749706 Manual brightness adjustment, no PoE

Camera with minimum demands needed


A single adapter for PoE (11749710)

Order no. 211A, network camera


110011749707 Bi-directional with audio, PoE compatible

This camera offers a two-way audio feature

Infrastructure Solutions
Order no. 221, network camera
110011749708 With infrared for use in darkness
Automatic change-over, PoE compatible

This camera offers functions for


demanding security installations in all
lighting conditions

Order no. 213, mobile network camera


110011749709 with 26x optical zoom, 12 x digital, PoE compatible

Zoom camera for optimum


room surveillance with 26x zoom
and infrared mode for optimum surveillance

Order no. PoE accessories


110011749710 PoE adapter for connection to individual
cameras

11749711 PoE rack, 6 x, for connecting


up to 6 cameras

Order no. Network switch


110011749714 With 4 x PoE

8 automatic sensing, 10/100 MBit/s RJ45 ports, can


supply power and data simultaneously through the PoE
and can be used for both camera types.

The installation of the cameras and software can be provided upon request.
Outdoor variants with weather-resistant housing are available upon request.
If you would like us to draw up a quotation to suit your individual conguration, please do not hesitate to contact us.

Lampertz 89
CMC-TC-System

Monitoring
Data losses or the failure of networks and production systems are for all connected sensor boxes. The dectection sensors are connected to the sensor
associated with enormous risks. The newest generation of monitoring tech- unit. So the function will be defined. The PU can be optionally operated by the
nology: the CMC-Top Concept. Never before rack security was so individual, simple CMC-TC-Master and provided higher perfomances. The whole system is completed
and cost-efcient. With the new CMC-TC system, all of the monitoring functions by the plug & play concept with automatic sensor detection and configuration. The
and sensors can be freely selected. An economical, target-orientated monitoring latest generation of monitoring technology. Thanks to new, decentralised functional
application can be built up with the CMC-TC-System. The Processing unit (PU) units you can now select the exact components to your individual requirements.
with the network interface is the basis. The sensor units will be connected to the This allows very individual and economical solutions. The openness of the modular
processing unit. The processing unit is designed to provide a central power supply system means that youre also optimally equipped for future extensions.

Central system control Security in the data centre Reliable cooling


Rittal CMC-TC - RiWatch IT for Access control, power supply, The control and monitoring of all
functional and security management temperature - Every factor climate components ensures
of all IT and cooling components. affecting IT availability is monitored. reliable, precise cooling.

90 Lampertz
CMC-TC-System

Computer Multi Control Top Concept The innovation of monitoring system


Even damage that can threaten a companys very existance can occur. So safeguard Flexibility
your companys life blood and ensure a stable information and production flow.All Thanks to its modular design and its almost unlimited extension, the CMC-TC grows
monitoring functions and sensors can be freely selected with the new CMC-Top system. along with your demands.
Compatibility Individuality
CMC-TC can communicate via all common protocols. CMC-TC can be fully adapted to your requirements, from decentralised monitoring by
Profitability individual processing units to control of the complete system by a master Unit.
CMC-TC allows the integration of the decentralised function modules into your IT-
system quickly and without unnecessary costs.

Your basic package for detection of smoke


oke and
excess temperature
Order no. CMC-TOP Concept, Basic Package
110010571080 PU unit, assembly kit, power supply unit,
2 x input sensors for:
a) Modular safe application:
1 x temperature sensor
2 x input sensor
4 x digital sensor, input module
b) Room applications:
1 x temperature sensor
7 x digital sensor, input module

Infrastructure Solutions
The sensor units Accessories
Order no. Processing Unit (PU) Order no. Installation unit 1 U
7320.100 The PU unit forms the basis 7320.440 Assembly kit for rack
for the monitoring system

Order no. Universal I/O Unit


7320.500 The I/O unit is the signal
Order no. Power unit 24 V DC
and alarm module
7320.425 CMC-TC power supply
Order no. ISDN-Unit
7320.830

Order no. Power supply cable


Order no. GSM-Unit
720.210 D/F/B
7320.820 720.211 GB
720.213 CH
720.214USA / CDN
Order no. Input sensors
7320.530 Order no. Cable for connection RJ 45
7320.472 Length: 2,0 m
7320.470 Length: 0,5 m
Sensors/actors
Order no. Smoke detection
7320.560 Detection based on an Order no. Cable clamp
analysis of electronical 7611.000
smoke aerosols

Order no. Temperature-sensor


Order no. Cable for programming
7320.500 The sensor takes over
the function of controlling 7200.221 For basic settings of the
temperature different addresses and parameters
of the PU, for rst operation

Order no. The input module


7320.580 facilitates the connection
of individual external digital + Free software: CMC-TC manager
The graphical interface reproduces the respective system information and offers the
sensors to a sensor unit
possibility of conguring the systems via SNMP.

Lampertz 91
Media Safes

Secure data storage and compliance of legal standards


The best high-tech data tapes, business-critical backups and knowledge of becoming entirely unable to operate. The law for control and transparency
bases are of little use if they are destroyed in burning desks or made unrea- in the company sector (KonTraG) demands that those responsible for data
dable by water used to extinguish res. processing create digital archives of their digital data. But dependence
Lampertz media safes in the DIS-DATA series protect frequently irreplacea- on normal protective safes will expose data protection ofcers and their
ble and sensitive data carriers from re, water, dust and smoke as well as businesses to incalculable liability risks.
theft and unauthorised access. And therefore help companies avoid the risk

92 Lampertz
Media Safes

Due to the modern business security it is essential to suitably protect


important data that has been saved to streamer and giga tapes, DVDs and
CD-ROMs. Such protection may be realized with tailor-made and cost-
efcient media safes by Lampertz certied in compliance with European
standards (ECBS).

Lampertz: security at its best

Media Safe

Lampertz DIS-DATA Media Safes are far ahead of burglar-


protected safes, as they offer protection for the valuable
and sensitive data-media against a variety of risks like re,
dust, corrosive gases or theft/burglary.

certied by:

Lampertz 93
Media Safes

Data protection with Media Safes


The more data you have, the more you need risk prevention. DIS-DATA safes are available in the S or SE models, both in 5 different sizes.
This applies both to large companies, governmental ofces and institutions, Fireproong according to EN 1047-1, quality class S120 DIS, is identical
as well as to freelancers and small or medium-sized companies. Floppy for both models. In addition the safes of the SE class are extremely burglar-
disks, magnetic tapes, streamer or giga-tapes and CDs are the morn media proof with resistance class II (according to EN 1143-1). The safes are
of today for archiving data. tested under extreme conditions and are delivered with the corresponding
Electronic data media concentrate the critical data of a company literally inspection certicates.
in a minimal amount of space with all the advantages and disadvantages The low weight of the safe, spacious interior, variable interior decoration
of a signicant security risk. There is only one way to protect yourself: data elements and extensive recycling speak for themselves. In addition, a
media has to be stored in a special data carrier safe! standard feature of the DIS-DATA safes is the fast closing by simply pushing
the safe door.

Explanation of symbols on the following pages: Standard protection against...

Fire Fire extingu- Corrosive Vandalism Unauthorized Dust Explosion Debris Theft/burglary Mechanical
ishing water gases access access

94 Lampertz
Media Safes

Overview DIS-DATA Safes


Classications:
S100 certied re protection in accordance with ECBS, type-tested in accordance with EN 1047-1, Quality Class S 60 DIS
S + SE certied re protection in accordance with ECBS, type-tested in accordance with EN 1047-1, Quality Class S 120 DIS
Only SE certied burglary protection in accordance with ECBS, type-tested in accordance with EN 1143 1, Resistance Class II

DIS-DATA
Business Line

DIS-DATA
Classic Line

Type S100 S11 / SE11 S12 / SE12 S13 / SE13 S14 / SE14 S15 / SE15
Fire-protection S 60 DIS S 120 DIS S 120 DIS S 120 DIS S 120 DIS S 120 DIS
Burglarproof (VDS) / WG II / WG II / WG II / WG II / WG II

Exterior dimensions (mm)


Height 712 732 1052 1295 1850 1850
Width 560 786 786 786 786 1195
Depth 770 918 918 918 918 918
Depth without door 722 770 770 770 770 770

Media Safe
Interior dimensions (mm)
Height 390 332 652 895 1450 1450
Width 290 444 444 444 444 855
Depth 460 470 470 470 470 470
Capacity (l) 52 71 139 191 310 590
Weight (kg) 203 S=288/SE=320 S=380/SE=460 S=445/SE=543 S=631/SE=785 S=922/SE=1000
Weight without door (kg) 181 223 282 326 456 630
Number of locking bolts 8 10 10 12 14

Detailed information about air-conditioning solutions for


automatic back-up drives are available on page 42.

Lampertz 95
Media Safes

S 100-Classic Line S / SE11- Classic Line

All safes without contents/decoration All safes without contents/decoration

DIS-DATA Safe S 100 -Classic Line DIS-DATA Safe S11 / SE11 - Classic Line

Order number 110010115534 Order number 110010113104 / 110010114104


Fire protection 60 Minutes Fire protection 120 Minutes
External dimensions H x W x D (mm) 712 x 560 x 770 Burglar protection SE WG II
Internal dimensions H x W x D (mm) 390 x 290 x 460 External dimensions H x W x D (mm) 732 x 786 x 918
Capacity (l) 52 Internal dimensions H x W x D (mm) 332 x 444 x 470
Weight (kg) without internal equipment 203 Capacity (l) 71
Middle surface load (kN/M2): Weight (kg) without internal equipment 288 / 320
(no load surface) 2.03 Middle surface load (kN/M2):
(large load surface) 1.65 (no load surface) 1.87 / 1.97
Colours RAL 7035 (Light grey) (large load surface) 1.57 / 1.63
Internal equipment 1 pull-out shelf with 2 dividers Colours RAL 7035 (Light grey)
Lock variant Spring-loaded lock, 2 rigid keys Internal equipment 1 pull-out shelf with 2 dividers
Lock variant Electronic pushbutton lock
Lock variant SE Mechanical key lock, 2 keys

Personal third-party liability ECBS certification


for data processing managers The EBCS (European Certification Board
Ever since the KonTraG law (law for control and transparency in the for Security Systems) test certificate is, in
company sector) came into force in 1998, it is a statutory require- fact, the FuPs (research and testing
ment that digital data be digitally archived. association for security systems) seal of
approval and
Making sure that your data are completely safe Lampertz
DIS-DATA safes! stands for high and consistent product
quality.

All offers without decoration. The FuP independently monitors the


* The pictures show the special edition with a non-standard coating which is available for Lampertz product range.
an additional charge (RAL 3020 (traffic red) / RAL 7042 (traffic grey) )

96 Lampertz
Classic Line

S / SE13 - Classic Line S / SE15 - Classic Line

All safes without contents/decoration All safes without contents/decoration

Media Safe
DIS-DATA Safe S13 / SE13-Classic Line DIS-DATA Safe S15 / SE15 - Classic Line

Order number 110010113304 / 110010114304 Order number 110010113504 / 110010114504


Fire protection 120 Minuten Fire protection 120 Minuten
Burglar protection SE WG II Burglar protection SE WG II
External dimensions H x W x D (mm) 1295 x 786 x 918 External dimensions H x W x D (mm) 1850 x 1195 x 918
Internal dimensions H x W x D (mm) 895 x 444 x 470 Internal dimensions H x W x D (mm) 1450 x 855 x 470
Capacity (l) 191 Capacity (l) 590
Weight (kg) without internal equipment 445 / 543 Weight (kg) without internal equipment 922 / 1040
Middle surface load (kN/M2): Middle surface load (kN/M2):
(no load surface) 2.50 / 2.79 (no load surface) 2.80 / 2.96
(large load surface) 2.00 / 2.21 (large load surface) 2.29 / 2.41
Colours RAL 7035 (Light grey) Colours RAL 7035 (Light grey)
Internal equipment 2 pull-out shelf with 2 dividers Internal equipment 3 pull-out shelf with 2 dividers
Lock variant Electronic pushbutton lock Lock variant Electronic pushbutton lock
Lock variant SE Mechanical key lock, 2 keys Lock variant SE Mechanical key lock, 2 keys

Certified security solution to ECBS


fire protection S 60 DIS in accordance with EN 1047-1 (S100)
fire protection S 120 DIS in accordance with EN 1047-1 (S 11, S 13 ,S 15)

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglary protection resistance class II acc. to EN 1143-1

Lampertz 97
Media Safes

DIS-DATA Safe S100 - Business Line


DIS-DATA Safe Order no.
Model S100
Door hinges right 10115510 A
Classication S60 DIS
Lock Spring-loaded
snap-in lock
Exterior dimensions in mm
Height 712
Width 560
Depth 770
Depth without door 722
Interior dimensions in mm
Height 390
Width 290
Depth 460
Internal volume in litres 52
Total weight in kg 203
Middle surface load
(no load surface) 2.03 kN/m2
(large load surface) 1.65 kN/m2

Option
1 additional key (additional charge) 1001552101

All safes without contents/decoration Individual interior tting: page 100

Type of lock (additional cost per each door) Description on page 101
Lock Selection options Order no.
Mechanical key lock Standard (2 keys) Standard
712

390

460

290

770
incl. handle
560

Volume: 52 l (Dimensions in mm)

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S100 Fire protection S 60 DIS acc. to EN 1047-1

98 Lampertz
DIS-DATA Safe S100

Complete for each S100 shelf level


Interior height/total unit height: 390 mm
390
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
66 2 33 144 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
192 4 48 80 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
63 3 21 112 1 x Pull-out shelf 1 x 110010015531
2 x Dividing bar, width 2 x 110010012682
64 2 32 176 1 x Pull-out shelf 1 x 110010015531
2 x Basket 2 x 110010014090
64 2 32 192 1 x Shelf 1 x 110010015535
1 x Basket 1 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
75 3 25 128 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
72 3 24 128 1 x Pull-out shelf 1 x 110010015531
2 x Basket 2 x 110010014090
48 2 24 144 1 x Shelf 1 x 110010015535
2 x Basket 2 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
365 5 73 64 1 x Pull-out shelf 1 x 110010015531
5 x Dividing bar, width 5 x 110010012682
240 4 60 80 1 x Pull-out shelf 1 x 110010015531
3 x Basket 3 x 110010014092
240 4 60 96 1 x Shelf 1 x 110010015535
3 x Basket 3 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
160 4 40 80 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
144 4 36 80 1 x Pull-out shelf 1 x 110010015531
2 x Basket 2 x 110010014093
108 3 36 112 1 x Shelf 1 x 110010015535
2 x Basket 2 x 110010014093

Media Safe
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
444 3 148 112 1 x Pull-out shelf 1 x 110010015531
4 x Dividing bar, width 4 x 110010012682
360 3 120 112 1 x Pull-out shelf 1 x 110010015531
2 x Basket 2 x 110010014065
360 3 120 128 1 x Shelf 1 x 110010015535
2 x Basket 2 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
108 2 54 160 1 x Pull-out shelf 1 x 110010015531
2 x Dividing bar, width 2 x 110010012682

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013112
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
132 2 66 144 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
108 2 54 144 1 x Pull-out shelf 1 x 110010015531
3 x Basket 3 x 110010014074
108 2 54 160 1 x Shelf 1 x 110010015535
3 x Basket 3 x 110010014074
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
210 5 42 64 1 x Pull-out shelf 1 x 110010015531
2 x Dividing bar, width 2 x 110010012682
Ultrium (105 x 102 x 22 mm) Archiving without cover
114 3 38 112 1 x Pull-out shelf 1 x 110010015531
3 x Dividing bar, width 3 x 110010012682
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
90 3 30 128 1 x Pull-out shelf 1 x 110010015531
2 x Dividing bar, width 2 x 110010012682
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
144 2 72 128 1 x Pull-out shelf 1 x 110010015531
2 x Dividing bar, width 2 x 110010012682

Lampertz 99
Media Safes

DIS-DATA Safe S11 / SE11- Business Line


DIS-DATA Safe Order no. Order no
Model S11 SE11
Door hinges right 110010113100 110010114100
Door hinges left (surcharge) 110010012545 110010012545
Fire protection S120 DIS S120 DIS
Burglary protection Resistance
class II
Number of locking bolts 8 8
Exterior dimensions in mm
Height 732 732
Width 786 786
Depth 918 918
Depth without door 770 770
Interior dimensions in mm
Height 332 332
Width 444 444
Depth 470 470
Internal volume in litres 71 71
Total weight in kg 288 320
Weight in kg without safe door 223 248
Middle surface load
(no load surface) 1.87 kN/m2 1.97 kN/m2
(large load surface) 1.57 kN/m2 1.63 kN/m2

Option
Extra key (additional charge) 110011701030 110011701031

All safes without contents/decoration Individual interior tting: page 100

Lock variants (additional charge) description on page 101


Lock Selection options Order no.
Mechanical key lock Standard (2 keys, model) Standard
Additional (2 keys, model) 110010012717

Electronic code Alternative 110010015160


combination lock Additional 110010015161
732

332

470

444

918
786

Volume: 71 l (Dimensions in mm)

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglar protection resistance class II acc. to EN 1143-1

100 Lampertz
DIS-DATA Safe S11 / SE11

Complete for each S11 / SE11 shelf level

Interior height/total unit height: 332 mm


332
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
120 2 60 144 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
336 4 84 80 1 x Pull-out shelf 1 x 110010013110
4 x Dividing bar, width 4 x 110010013111
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
76 2 38 112 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
48 1 48 176 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
48 1 48 192 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
92 2 46 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
72 2 36 128 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
72 2 36 144 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
595 5 119 64 1 x Pull-out shelf 1 x 110010013110
5 x Dividing bar, width 5 x 110010013111
400 4 100 80 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014092
300 3 100 96 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
304 4 76 80 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013110
216 4 54 80 1 x Pull-out shelf 1 x 110010015531
3 x Basket 3 x 110010014093
162 3 54 112 1 x Shelf 1 x 110010013122

Media Safe
3 x Basket 2 x 110010014093
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
480 2 240 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
480 2 240 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
162 2 81 160 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
218 2 109 144 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
180 2 90 144 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014075
180 2 90 160 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014075
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
360 5 72 64 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Ultrium (105 x 102 x 22 mm) Archiving without cover
136 2 68 112 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
90 2 45 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
198 2 99 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Valuables compartment (exterior H 180 x W 422 x D 390 mm) (interior H 151 x W 402 x D 357 mm) 1 x 110010013140

Lampertz 101
Media Safes

DIS-DATA Safe S12 / SE12- Business Line


DIS-DATA Safe Order no. Order no.
Model S12 SE12
Door hinges right 110010113200 110010114200
Door hinges left (surcharge) 110010012545 110010012545
Fire protection S120 DIS S120 DIS
Burglary protection Resistance
class II
Number of locking bolts 10 10
Exterior dimensions in mm
Height 1052 1052
Width 786 786
Depth 918 918
Depth without door 770 770
Interior dimensions in mm
Height 652 652
Width 444 444
Depth 470 470
Internal volume in litres 139 139
Total weight in kg 380 460
Weight in kg without safe door 282 350
Middle surface load
(no load surface) 2,.30 kN/m2 2.54 kN/m2
(large load surface) 1.87 kN/m2 2.03 kN/m2

All safes without contents/decoration Individual interior tting: page 100

Lock variants (additional cost) description on page 101


Lock Selection options Order no.
Mechanical key lock Standard Standard
Additional 110010012717

Digital electronic Alternative 110010015125


combination lock Additional 110010015126

Electronic code Alternative 110010015160


1052

combination lock Additional 110010015161


652

470

Electronic lock, 12 V o. 24 V Alternative 110010012701


444 for code card reader* Additional 110010012712
* not included
918
786

Volume: 139 l (Dimensions in mm)

Farben:

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglar protection resistance class II acc. to EN 1143-1

102 Lampertz
DIS-DATA Safe S12 / SE12

Complete for each S12 / SE12 shelf level


Interior height/total unit height: 652 mm
652
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
240 4 60 144 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
627 8 84 80 1 x Pull-out shelf 1 x 110010013110
4 x Dividing bar, width 4 x 110010013111
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
190 5 38 112 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
144 3 48 176 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
144 3 48 192 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
280 5 46 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
180 5 36 128 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
144 4 36 144 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
1190 10 119 64 1 x Pull-out shelf 1 x 110010013110
5 x Dividing bar, width 5 x 110010013111
800 8 100 80 1 x Pull-out shelf 1 x 110010013110
5 x Basket 5 x 110010014092
600 6 100 96 1 x Shelf 1 x 110010013122
5 x Basket 5 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
608 8 76 80 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
432 8 54 80 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014093
270 5 54 112 1 x Shelf 1 x 110010013122

Media Safe
3 x Basket 3 x 110010014093
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
1200 5 240 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
960 4 240 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
324 4 81 160 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
436 4 109 144 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
360 4 90 144 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014075
360 4 90 160 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014075
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
720 10 72 64 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Ultrium (105 x 102 x 22 mm) Archiving without cover
340 5 68 112 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
180 4 45 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
396 4 99 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Valuables compartment (exterior H 180 x W 422 x D 390 mm) (interior H 151 x W 402 x D 357 mm) 1 x 110010013140

Lampertz 103
Media Safes

DIS-DATA Safe S13 / SE13- Business Line


DIS-DATA Safe Order no. Order no.
Model S13 SE13
Door hinges right 110010113300 110010114300
Door hinges left (surcharge) 110010012545 110010012545
Fire protection S120 DIS S120 DIS
Burglary protection Resistance
class II
Number of locking bolts 10 10
Exterior dimensions in mm
Height 1295 1295
Width 786 786
Depth 918 918
Depth without door 770 770
Interior dimensions in mm
Height 895 895
Width 444 444
Depth 470 470
Internal volume in litres 191 191
Total weight in kg 445 543
Weight in kg without safe door 326 404
Middle surface load
(low load surface) 2.50 kN/m2 2.79 kN/m2
(large load surface) 2.00 kN/m2 2.21 kN/m2

All safes without contents/decoration Individual interior tting: page 100

Lock variants (additional cost) Description on page 101


Lock Selection options Order no.
Mechanical key lock Standard Standard
Additional 110010012717

Digital electronic Alternative 110010015125


combination lock Additional 110010015126
1295

470 Electronic code Alternative 110010015160


895

combination lock Additional 110010015161

Electronic lock, 12 V o. 24 V Alternative 110010012701


444 for code card reader* Additional 110010012712
* not included
918
786

Volume: 191 l (Dimensions in mm)

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglar protection resistance class II acc. to EN 1143-1

104 Lampertz
DIS-DATA Safe S13 / SE13

Complete for each S13 / SE13 shelf level


Interior height/total unit height: 895 mm
895
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
360 6 60 144 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
924 11 84 80 1 x Pull-out shelf 1 x 110010013110
4 x Dividing bar, width 4 x 110010013111
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
266 7 38 112 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
240 5 48 176 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
192 4 48 192 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
322 7 46 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
252 7 36 128 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
216 6 36 144 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
1666 14 119 64 1 x Pull-out shelf 1 x 110010013110
5 x Dividing bar, width 5 x 110010013111
1100 11 100 80 1 x Pull-out shelf 1 x 110010013110
5 x Basket 5 x 110010014092
900 9 100 96 1 x Shelf 1 x 110010013122
5 x Basket 5 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
836 11 76 80 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
594 11 54 80 1 x Pull-out shelf 1 x 110010013110

Media Safe
3 x Basket 3 x 110010014093
432 8 54 112 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014093
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
1920 8 240 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
1680 7 240 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
405 5 81 160 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
654 6 109 144 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
540 6 90 144 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014075
450 5 90 160 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014075
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
936 13 72 64 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Ultrium (105 x 102 x 22 mm) Archiving without cover
476 7 68 112 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
315 7 45 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
693 7 99 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Valuables compartment (exterior H 180 x W 422 x D 390 mm) (interior H 151 x W 402 x D 357 mm) 1 x 110010013140

Lampertz 105
Media Safes

DIS-DATA Safe S14 / SE14- Business Line


DIS-DATA Safe Order no. Order no.
Model S14 SE14
Door hinges right 110010113400 110010114400
Door hinges left (surcharge) 110010012545 110010012545
Fire protection S120 DIS S120 DIS
Burglary protection Resistance
class II
Number of locking bolts 12 12
Exterior dimensions in mm
Height 1850 1850
Width 786 786
Depth 918 918
Depth without door 770 770
Interior dimensions in mm
Height 1450 1450
Width 444 444
Depth 470 470
Internal volume in litres 310 310
Total weight in kg 631 785
Weight in kg without safe door 456 574
Middle surface load
(low load surface) 3.20 kN/m2 3.67 KN/m2
(large load surface) 2.50 kN/m2 2.83 kN/m2

All safes without contents/decoration Individual interior tting: page 100

Lock variants (additional cost) Description on page 101


Lock Selection options Order no.
Mechanical key lock Standard Standard
Additional 110010012717

Digital electronic Alternative 110010015125


combination lock Additional 110010015126

Electronic code Alternative 110010015160


1850

1450

470 combination lock Additional 110010015161

Electronic lock, 12 V o. 24 V Alternative 110010012701


for code card reader* Additional 110010012712
444
* not included

918

786

Volume: 310 l (Dimensions in mm)

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglar protection resistance class II acc. to EN 1143-1

106 Lampertz
DIS-DATA Safe S14 / SE14

Complete for each S14 / SE14 shelf level


Interior height/total unit height: 1450 mm
1450
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
600 10 60 144 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
1512 18 84 80 1 x Pull-out shelf 1 x 110010013110
4 x Dividing bar, width 4 x 110010013111
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
456 12 38 112 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
384 8 48 176 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
336 7 48 192 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
506 11 46 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
396 11 36 128 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014090
360 10 36 144 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
2618 22 119 64 1 x Pull-out shelf 1 x 110010013110
5 x Dividing bar, width 5 x 110010013111
1800 18 100 80 1 x Pull-out shelf 1 x 110010013110
5 x Basket 5 x 110010014092
1500 15 100 96 1 x Shelf 1 x 110010013122
5 x Basket 5 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
1368 18 76 80 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
972 18 54 80 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014093
648 12 54 112 1 x Shelf 1 x 110010013122

Media Safe
3 x Basket 3 x 110010014093
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
3120 13 240 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2640 11 240 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
648 8 81 160 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
1090 10 109 144 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
900 10 90 144 1 x Pull-out shelf 1 x 110010013110
3 x Basket 3 x 110010014075
810 9 90 160 1 x Shelf 1 x 110010013122
3 x Basket 3 x 110010014075
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
1584 22 72 64 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Ultrium (105 x 102 x 22 mm) Archiving without cover
816 12 68 112 1 x Pull-out shelf 1 x 110010013110
3 x Dividing bar, width 3 x 110010013111
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
495 11 45 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 2 x 110010013112
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
999 10 99 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Valuables compartment (exterior H 180 x W 422 x D 390 mm) (interior H 151 x W 402 x D 357 mm) 1 x 110010013140

Lampertz 107
Media Safes

DIS-DATA Safe S15 / SE15- Business Line


DIS-DATA Safe Order no. Order no.
Model S15 SE15
Door hinges right 110010113500 110010114500
Door hinges left (surcharge) 110010012545 110010012545
Fire protection S120 DIS S120 DIS
Burglary protection
Resistance
class II
Number of locking bolts 14 14
Exterior dimensions in mm
Height 1850 1850
Width 1195 1195
Depth 918 918
Depth without door 770 770
Interior dimensions in mm
Height 1450 1450
Width 855 855
Depth 470 470
Internal volume in litres 590 590
Total weight in kg 922 1000
Weight in kg without safe door 630 814
Middle surface load
(low load surface) 2.80 kN/m2 2.96 KN/m2
(large load surface) 2.29 kN/m2 2.41 kN/m2

All safes without contents/decoration Individual interior tting: page 100

Lock variants (additional cost) Description on page 101


Lock Selection options Order no.
Mechanical key lock Standard Standard
Additional 110010012717

Digital electronic Alternative 110010015125


combination lock Additional 110010015126

Electronic code Alternative 110010015160


1850

1450

470
combination lock Additional 110010015161

Electronic lock, 12 V o. 24 V Alternative 110010012701


for code card reader* Additional 110010012712
* not included
855

918
1195

Volume: 590 l (Dimensions in mm)

Fire and burglar proof storage of documents and magnetic data media.
Colours:

Light gray, RAL 7035 Red, RAL 3020 Violet blue, RAL 5000 Black, RAL 9005

S Fire protection S 120 DIS acc. to EN 1047-1

SE Fire protection S 120 DIS acc. to EN 1047-1 and burglar protection resistance class II acc. to EN 1143-1

108 Lampertz
DIS-DATA Safe S15 / SE15

Complete for each S15 / SE15 shelf level

Interior height/total unit height: 1450 mm


1450
mm

Capacity per safe Data per level

Designation (dimension) Capacity Number Capacity Height Interior Order no. per level
per safe of the per level unit outtting
Levels in mm elements

MB 3480, 3490, 3590, 3592, 9840, 9940, T 10000 (108 x 123 x 25 mm) Archiving without cover
1240 10 124 144 1 x Pull-out shelf 1 x 110010013510
3 x Dividing bar, width 3 x 110010013511
Mini Data Cartridge MLR / SLR (89 x 66 x 20 mm) Archiving with cover
3060 18 170 80 1 x Pull-out shelf 1 x 110010013510
4 x Dividing bar, width 4 x 110010013511
Maxi Data Cartridge / MLR / SLR (161 x 107 x 25 mm) Archiving with cover
936 12 78 112 1 x Pull-out shelf 1 x 110010013510
2 x Dividing bar, width 2 x 110010013511
768 8 96 176 1 x Pull-out shelf 1 x 110010013510
6 x Basket 6 x 110010014090
784 7 112 192 1 x Shelf 1 x 110010013123
7 x Basket 7 x 110010014090
DLT, S-DLT, DLT-S, DLT-V, DLT-VS (111 x 113 x 32 mm) Archiving with cover
1078 11 98 128 1 x Pull-out shelf 1 x 110010013510
6 x Dividing bar, depth 6 x 110010013112
792 11 72 128 1 x Pull-out shelf 1 x 110010013510
6 x Basket 6 x 110010014090
840 10 84 144 1 x Shelf 1 x 110010013123
7 x Basket 7 x 110010014090
DAT / DDS Tape (81 x 59 x 15 mm) Archiving with cover
5368 22 244 64 1 x Pull-out shelf 1 x 110010013510
5 x Dividing bar, width 5 x 110010013511
3240 18 180 80 1 x Pull-out shelf 1 x 110010013510
9 x Basket 9 x 110010014092
2700 15 180 96 1 x Shelf 1 x 110010013123
9 x Basket 9 x 110010014092
VXA Tape, Mammoth Tape (103 x 68 x 21 mm) Archiving with cover
2736 18 152 80 1 x Pull-out shelf 1 x 110010013510
3 x Dividing bar, width 3 x 110010013511
2268 18 126 80 1 x Pull-out shelf 1 x 110010013510
7 x Basket 7 x 110010014093
1512 12 126 112 1 x Shelf 1 x 110010013123

Media Safe
7 x Basket 7 x 110010014093
Optical-Disk 3,5 MOD (94 x 90 x 6 mm) Archiving in slider box
6240 13 480 112 1 x Pull-out shelf 1 x 110010013510
8 x Basket 8 x 110010014065
5280 11 480 128 1 x Shelf 1 x 110010013123
8 x Basket 8 x 110010014065
Optical-Disk 5,25 MOD, UDO (137 x 154 x 12 mm) Archiving in slider box
1488 8 186 160 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111

Disc 3 (94 x 94 x 3mm) (1 Pcs.) Archiving without cover


3200 8 400 112 1 x Pull-out shelf 1 x 110010013110
4 x Basket 4 x 110010014065
2800 7 400 128 1 x Shelf 1 x 110010013122
4 x Basket 4 x 110010014065
CD ROM, CD, DVD Jewel Case (142 x 125 x 10 mm) Archiving with cover / Slime case (142 x 125 x 5 mm) = Double quantity!
2320 10 232 144 1 x Pull-out shelf 1 x 110010013510
2 x Dividing bar, width 2 x 110010013511
1500 10 150 144 1 x Pull-out shelf 1 x 110010013510
5 x Basket 5 x 110010014075
1350 9 150 160 1 x Shelf 1 x 110010013123
5 x Basket 5 x 110010014075
Magstar MP or Magstar 3570 (137 x 59 x 16,5 mm) Archiving without cover
3168 22 144 64 1 x Pull-out shelf 1 x 110010013510
2 x Dividing bar, width 2 x 110010013511
Ultrium (105 x 102 x 22 mm) Archiving without cover
1680 12 140 112 1 x Pull-out shelf 1 x 110010013510
6 x Dividing bar, width 6 x 110010013112
LTO Ultrium (110 x 115 x 27 mm) Archiving with cover
1056 11 96 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, depth 5 x 110010013112
DVD RAM (127 x 139 x 9 mm) Archiving in caddy / slider box
2430 10 243 128 1 x Pull-out shelf 1 x 110010013110
2 x Dividing bar, width 2 x 110010013111
Valuables compartment (exterior H 180 x W 422 x D 390 mm) (interior H 151 x W 402 x D 357 mm) 1 x 110010013145

Lampertz 109
Equipment DIS-DATA Safes

Interior equipment DIS-DATA Safes S / SE11-15


Components for individual interior equipment of DIS-DATA safes Your advantage: You always know where to nd the data media you are
Efciency becomes apparent in the details. With the right interior equipment looking for. Information about the capacity of the components in the various
you can use the capacity of the Lampertz media safes efciently and intel- safes can be found either in the preceding charts or what is easier: You
ligently. Diverse equipments are an integral aspect of modular furnishing can contact Lampertz directly. Our specially trained staff will provide you
concepts and considerably expand the possibilities available to you. free organizational support.
The shelves can be adjusted to your specic needs by means of the internal
hole matrix. An additional matrix in the outer frame enables the perfect
adaptation of the pull-out panels to the number and size of the data media.
In this way you can adapt the facility to your individual needs.

Pull-out shelf Dimensions (mm) Order no.


DIS-DATA Safe S100 250 x 448 110010015531
DIS-DATA Safe S/SE11-14 400 x 460 110010013110
DIS-DATA Safe S/SE15 807 x 460 110010013510
(Max. load of telescopic tray: 70 kgs.)

Dividing bar for pull-out shelf Dimensions (mm) Order no.

DIS-DATA Safe S/SE11-14 (for the width) 400 110010013111


DIS-DATA Safe S/SE15 (for the width) 807 110010013511
DIS-DATA Safe S/SE11-15 (for the depth) 460 110010013112
DIS-DATA Safe S100 (for the width) 250 110010012682

Notched dividing bar for pull-out shelf


(for variable sectionalization of pull-out shelf) Dimensions (mm) Order no.
DIS-DATA Safe S/SE11-14 (for the width) 400 110010013130
DIS-DATA Safe S/SE15 (for the width) 807 110010013131
DIS-DATA Safe S/SE11-15 (for the depth) 460 110010013132

Fixed Shelf Dimensions (mm) Order no.


DIS-DATA Safe S100 288 x 420 110010015535
DIS-DATA Safe S/SE11-14 442 x 420 110010013122
DIS-DATA Safe S/SE15 851 x 420 110010013123
(Max. load of shelf: 70 kgs.)

Valuables compartment insert, lockable, single-door Dimensions (mm) Order no.


DIS-DATA Safe S/SE11-14 110010013140
H x B x T (interior) 151 x 402 x 357
H x B x T (exterior) 180 x 442 x 390

Valuables compartment insert, lockable, double-door Dimensions (mm) Order no.


DIS-DATA Safe S/SE15 110010013145
H x B x T (interior) 151 x 388 x 357
H x B x T (exterior) 180 x 853 x 390

Storage baskets Capacity (pcs.) Dimensions (mm) Order no.


Disk 3 1/2 100 420 (long) 110010014065
Optical-Disk 31/2 60 420 (long) 110010014065
CD-ROM 30 420 (long) 110010014075
Streamer-Tape 16 110010014090
DLT-cardridge 12 110010014090
Giga-Tape 4 20 110010014092
Giga-Tape/Video 8 18 110010014093

110 Lampertz
Lock Variants Media Safes

Overview lock variants to be used in media safes

Mechanical key lock (Illustration shows the protective covering for insertion of the key) Digital electronic combination lock

Option Option
Protected lock, VdS-tested High-security electro-mechanical lock designed as redundant system. That
Key that cannot be removed when the lock is open means that in case of unexpected loss of code lock (user forgets the code,
fault in the electronic circuitry etc.), a revision key can be used to open the
lock in case of emergency (= override lock). It is then not necessary to know
the valid code. After opening the lock with the revision key, which is the
same as a master key, a new code can be assigned.
With a mechanical override lock made of steel in case emergency
opening is necessary
VdS-tested, class 1
6, 7 or 8 digit opening code can be programmed
Acoustic input conrmation of each keystroke
Low power requirement
Blocking after 3 erroneous code inputs (1, 2, 4, 8, 16 minutes)
Battery (9 Volt block battery) integrated in the input unit

Media Safe

Electronic code combination lock SELO A Electronic lock for code card reader* 24 Volt/12 Volt

Option Option
The electronic lock can be set for two opening methods: either for immedate Electromechanical high-security lock, electronic for code card controls.
opening upon entering of one of the valid 6-digit secret codes or for delayed That means: Lock can be connected to an existing access control system.
opening after a pre-programmes opening delay has lapsed. The lock is With mechanical override lock
unlocked using one of a total of nine secret codes. Revision lock with two-way key
%#"s3LOCKCLASS! Low power requirement
VdS-lock class 1 Blocked after 3 wrong code inputs
LED plus symbol Compatible with customized access control system via dened interface
Maximum number of users: up to 9 Important: No VdS version
Opening delay 0-99 min.
*Code card scanner not included in scope of delivery!

Lampertz 111
Functional Safeguard

Lampertz Functional Safeguard


Solutions for preventative structural re protection
In Germany, even greater importance has been placed on the issue of now represents the state of the art, provides clear specications. All in all,
structural re protection. Numerous special building regulations were an increased degree of sensitization can be detected. However, theoretical
introduced and adapted for special buildings being used for special pur- structural re protection is only as effective as the degree to which it is put
poses. Even the German Power Installation Guidelines, the basis of which into practice.

112 Lampertz
Structural Fire Protection

Structural Fire Protection


Dont react prevent

The aim of preventative structural re


protection:
N Maintaining the function of electrical systems
relevant to safety.
N Protecting emergency exit areas and escape
routes.

Statutory regulations: If a re breaks out, you have just 3 minutes to escape!

N State laws
N The German power installation guidelines now
represent the state-of-the-art for the entire Fed-
eral Republic. They provide concrete statements
regarding the above-mentioned aims.

Responsibility for re protection:


N The company board of management must per-
form suitable measures (monitoring system) for
re protection.
N As the system operator, the employer is responsi-
ble for protecting his employees and assets.
N Each employee is responsible for taking re-
protection measures within his work area.

Conclusion:
An optimum solution concept must offer:
N Protection against an existential threat to com-
panies and public buildings
N A guarantee that the best possible security is
provided for people, even in panic situations.

Functional Safeguard

Explanation of symbols on the following pages: Standard protection against...

Fire Corrosive gases Unauthorized


access

Lampertz 113
Wall-Mounted Current Distributor

Wall-mounted current distributor


Product description:
N Sandwich-type construction consisting of re-protection panels with
exterior and interior surface coating
N In one-door design standard, door opening: to the right
N In two-door design standard, door opening: 1 x to the right and 1 x to
the left
N 3-point door locking system
N Activated by turning lever
N Door is ush with the housing when locked
N Smoke-resistant sealing system in the seam around the perimeter of the
housing
N Fire-protection sealing system in the door seam and in the seam of the
housing acting as a re and temperature barrier
N Cable entry system in the top of the housing
N Colour light grey
N Screw sockets have been mounted in the factory for attaching installation
frames and mounting plates

Classication:
Resistant to re, from the inside towards the outside and from the outside
towards the inside for a duration of 30 or 90 minutes.
Function is safeguarded for 30 or 90 minutes (E 30 / E 90)

Advantages:
N Ball-bearing stainless-steel joint hinges
N Fire-protection panels with interior and exterior surface coating
N Freely-assignable cable entry system
N Also available with ttings for various installation frames and mounting plates.

Ball-bearing joint hinges made of stainless steel System-tested cable entry in the top of the
with constructionregulatory test certicate. Bear- housing for the exible insertion
ing load per joint hinge 100 kg of all supply cables

Wall-mounted current distributor


Order no. Description Interior dimensions Exterior dimensions Dimensions Number of Number of Number of Number of Weight
in mm in mm of pads doors pads rows TE appr. in kg

Lampertz Wall-mounted current distributor E 30 without ventilation interior depth 206


110011511102 E 30 614 x 256 x 206 756 x 394 x 323 600 x 250 1 1 4 48 77
110011511104 E 30 614 x 506 x 206 756 x 644 x 323 600 x 500 1 2 4 96 108
110011511105 E 30 764 x 506 x 206 906 x 644 x 323 750 x 500 1 2 5 120 125
110011511106 E 30 914 x 506 x 206 1056 x 644 x 323 900 x 500 1 2 6 144 142
110011511107 E 30 1064 x 506 x 206 1206 x 644 x 323 1050 x 500 1 2 7 208 159
110011511108 E 30 764 x 756 x 206 906 x 894 x 323 750 x 750 2 3 5 180 161
110011511111 E 30 1214 x 756 x 206 1356 x 894 x 323 1200 x 750 2 3 8 288 223

Lampertz Wall-mounted current distributor E 90 without ventilation interior depth 206


110011512102 E 90 614 x 256 x 206 790 x 429 x 341 600 x 250 1 1 4 48 77
110011512104 E 90 614 x 506 x 206 790 x 679 x 341 600 x 500 1 2 4 96 108
110011512105 E 90 764 x 506 x 206 940 x 679 x 341 750 x 500 1 2 5 120 125
110011512106 E 90 914 x 506 x 206 1090 x 679 x 341 900 x 500 1 2 6 144 142
110011512107 E 90 1064 x 506 x 206 1240 x 679 x 341 1050 x 500 1 2 7 208 159
110011512110 E 90 1064 x 756 x 206 1240 x 929 x 341 1050 x 750 2 3 7 252 202

Standard protection against:

Additional measurements available upon request!


114 Lampertz
Free-Standing Current Distributor

Free-standing current distributor


Product description:
N Sandwich-type construction consisting of re-protection panels with
exterior and interior surface coating
N In one-door design standard, door opening: to the right
N In two-door design standard, door opening: 1 x to the right and 1 x to the left
N 3-point door locking system
N Activated by turning lever
N Door is ush with the housing when locked
N Smoke-resistant sealing system in the seam around the housing perimeter
N Fire-protection sealing system positioned in the door seam and the seam
around the housing perimeter re and temperature barrier
N Cable entry system in the top and base elements of the housing
N Colour light grey
N Screw sockets have been mounted in the factory for attaching installation
frames and mounting plates
N Pedestal 100 mm high, can be accessed from below for forklift transportation
N Pedestal cover

Classication:
Resistant to re, from the inside towards the outside and from the outside
towards the inside for a duration of 30 or 90 minutes. Function is safe-
guarded for 30 or 90 minutes (E 30 / E 90)

Advantages:
N Ball-bearing stainless-steel joint hinges
N Fire-protection panels with interior and exterior surface coating
N Freely-assignable cable entry system
N Also available with ttings for various installation frames and mounting plates.

Ergoform turning lever prepared for the Ventilation with fire-protection valve
use of a profile half cylinder Optional: fan and cold smoke barrier

Free-standing current distributor


Order no. Description Interior dimensions Exterior dimensions Dimensions Number of Number of Number of Number of Weight
in mm in mm of pads doors pads rows TE appr. in kg

Functional Safeguard
Lampertz Free-standing current distributor E 30 without Ventilation interior depth 206
110011511402 E 30 1814 x 256 x 206 2054 x 394 x 346 1800 x 250 1 1 12 144 183
110011511405 E 30 1814 x 506 x 206 2054 x 644 x 346 1800 x 500 1 2 12 288 247
110011511408 E 30 1814 x 756 x 206 2054 x 894 x 346 1800 x 750 2 3 12 432 311

Lampertz Free-standing current distributor E 30 without Ventilation interior depth 306


110011511502 E 30 1814 x 256 x 306 2054 x 394 x 446 1800 x 250 1 1 12 144 159
110011511505 E 30 1814 x 506 x 306 2054 x 644 x 446 1800 x 500 1 2 12 288 208
110011511508 E 30 1814 x 756 x 306 2054 x 894 x 446 1800 x 750 2 3 12 432 258

Lampertz Free-standing current distributor E 90 without Ventilation interior depth 206


110011512402 E 90 1814 x 256 x 206 2069 x 429 x 382 1800 x 250 1 1 12 144 183
110011512405 E 90 1814 x 506 x 206 2069 x 679 x 382 1800 x 500 1 2 12 288 247
110011512408 E 90 1814 x 756 x 206 2069 x 929 x 382 1800 x 750 2 3 12 432 311

Lampertz Free-standing current distributor E 90 without Ventilation interior depth 306


110011512502 E 90 1814 x 256 x 306 2069 x 429 x 482 1800 x 250 1 1 12 144 217
110011512505 E 90 1814 x 506 x 306 2069 x 679 x 482 1800 x 500 1 2 12 288 284
110011512508 E 90 1814 x 756 x 306 2069 x 929 x 482 1800 x 750 2 3 12 432 352

Standard protection against:

Additional measurements available upon request!


Lampertz 115
Door and Dividing Wall System

Modular door and dividing wall system


The Lampertz door and dividing wall system offers a exibly-adjustable solu-
tion for protecting electrical control systems and distributors against re, as
well as insulation against re for emergency exits and escape routes. Thanks
to its modularity, it is possible to easily adjust it individually to suit the con-
ditions on site and thus to the housing containing existing equipment.

Product description:
N Modules in sandwich-type construction, consisting of re-protection
panels with exterior surface coating
N In one-door design standard, door opening: to the right
N In two-door design standard, door opening: 1 x to the right and 1 x to
the left
N 3-point door locking system
N Activated by turning lever
N Door is ush with the housing when locked
N Smoke-resistant sealing system in the seam around the perimeter of the
door element frame
N Fire-protection sealing system positioned in the door seam and the seam
of the door element frame to act as a re and temperature barrier
N The door elements can be installed in and removed from the door ele-
ment frame (for simplifying installation and maintenance)
N Colour: light grey

Use:
N For housing electrical control systems and current distributors
N For separating areas with a potential re risk from emergency exit areas
and escape routes
N For providing support in case of re in safeguarding of electrical systems
which are supplying essential safety devices
N For separating of accessible riser pipe ducts for reduction of re loads of
electrical systems and cables, as well as other piping systems in areas with
a potential re risk
N For construction of completely accessible riser pipe ducts at later stage
(also in emergency exit areas and escape routes).
N For setting up a separate electrical service room

Classication:
Fire resistance class F 30 / F 90 according to DIN 4102, part 2
Resistant to re, from inside towards the outside, for a duration of 30 or 90
minutes Supports the safeguarding of the equipments function for 30 or 90
minutes

Advantages:
N Modular
N Flexible combination
N Variable designs
N Expandable
N Prefabricated modules
N Quick, clean and dust-free installation

We offer optimum customer service for restoring existing build-


ings and planning of new buildings why not ask for us today!

Standard protection against:

116 Lampertz
Fire-Protection Cable Ducts

Fire-protection cable ducts


Product description:
N Prefabricated re-protection cable-duct system
N Encased in galvanized sheet steel
N Insulation is available using either very light calcium silicate panels or
modied natural wool panels (the E 90 is only available with calcium
silicate panels)
N Fire-protection cable-duct elements are available for all classications as
1200 mm long straight pieces and as form-elements in different shapes
N In addition to the standard sizes, the ducts are also available in all permissible
dimensions
N All sizes can be supplied in either two, three or four-sided design
N Suspension is possible, in using: Threaded rods Mounting rails Suspension
shafts Brackets Consoles Can be attached directly to the wall or ceiling
Classication:
Resistant to re, from inside towards the outside, for 30 or 90 minutes (I 30 /
I 90) Function is safeguarded for 30 or 90 minutes (E 30 / E 90)
Advantages:
N Weight-saving insulation materials
N Prefabricated
N Can be assembled on two, three or four sides
N Direct attachment possible, even on light dividing walls
N Extremely simple retrotting of data and supply cabling

Fire-protection cable ducts


Order no. Description Interior dimensions Exterior dimensions Length Weight
in mm in mm appr. in kg

Fire-protection cable duct E 30 / I 30 and form pieces, casing sheet steel zinc-plated, Insulation, mineral bre plates 30 mm
110011515100 Fire-protection cable duct E 30 / I 30 60 x 50 124 x 113 1200 6,0
110011515110 Fire-protection cable duct E 30 / I 30 110 x 50 174 x 113 1200 7,0
110011515120 Fire-protection cable duct E 30 / I 30 210 x 50 274 x 113 1200 10,0
110011515130 Fire-protection cable duct E 30 / I 30 160 x 100 224 x 163 1200 10,0
110011515140 Fire-protection cable duct E 30 / I 30 260 x 100 324 x 163 1200 12,0

Fire-protection cable duct E 60 / I 60 and form pieces, casing sheet steel zinc-plated, Insulation, mineral bre plates 40 mm
110011515200 Fire-protection cable duct E 60 / I 60 60 x 50 144 x 133 1200 8,0
110011515220 Fire-protection cable duct E 60 / I 60 210 x 50 294 x 133 1200 12,0
110011515230 Fire-protection cable duct E 60 / I 60 160 x 100 244 x 183 1200 12,0
110011515240 Fire-protection cable duct E 60 / I 60 260 x 100 344 x 183 1200 15,0

Fire-protection cable duct I 90 and form pieces, casing sheet steel zinc-plated, Insulation, mineral bre plates 40 mm
110011515300 Fire-protection cable duct I 90 60 x 50 144 x 133 1200 8,0
110011515310 Fire-protection cable duct I 90 110 x 501 94 x 133 1200 9,0
110011555320 Fire-protection cable duct I 90 210 x 50 294 x 133 1200 12,0
110011515330 Fire-protection cable duct I 90 160 x 100 244 x 183 1200 12,0

Functional Safeguard
110011515340 Fire-protection cable duct I 90 260 x 100 344 x 183 1200 15,0

Fire-protection cable duct E 30 and form pieces, casing sheet steel zinc-plated, Insulation, calcium silicate plates 40 mm
110011516100 Fire-protection cable duct E 30 60 x 50 144 x 133 1200 10,0
110011516110 Fire-protection cable duct E 30 110 x 50 194 x 133 1200 12,0
110011516120 Fire-protection cable duct E 30 210 x 50 294 x 133 1200 16,0
110011516130 Fire-protection cable duct E 30 160 x 100 244 x 183 1200 16,0
110011516140 Fire-protection cable duct E 30 260 x 100 344 x 183 1200 20,0

Fire-protection cable duct E 60 and form pieces, casing sheet steel zinc-plated, Insulation, calcium silicate plates 50 mm
110011516200 Fire-protection cable duct E 60 60 x 50 164 x 153 1200 13,0
110011516210 Fire-protection cable duct E 60 110 x 50 214 x 153 1200 15,0
110011516220 Fire-protection cable duct E 60 210 x 50 314 x 153 1200 20,0
110011516230 Fire-protection cable duct E 60 160 x 100 264 x 203 1200 20,0
110011516240 Fire-protection cable duct E 60 260 x 100 364 x 203 1200 25,0

Fire-protection cable duct E 90 and form pieces, casing sheet steel zinc-plated, Insulation, calcium silicate plates 55 mm
110011516300 Fire-protection cable duct E 90 60 x 50 174 x 163 1200 15,0
110011516310 Fire-protection cable duct E 90 110 x 50 224 x 163 1200 17,0
110011516320 Fire-protection cable duct E 90 210 x 50 324 x 163 1200 22,0
110011516330 Fire-protection cable duct E 90 160 x 100 274 x 213 1200 22,0
110011516340 Fire-protection cable duct E 90 260 x 100 374 x 213 1200 27,0

Standard protection against:

Shaped parts and special dimensions upon request!


Lampertz 117
System solutions for workplace visions
With the SPECTRO-DATA Vision, Lampertz has developed over many decades The system is the best choice for data centre, task console, network operation
a modern and exible furnishing system which supports your company to centre and communication applications. Spectro-Data Vision is perfectly sui-
meet future challenges. The modular system can be congured individually and table as well for 24/7 workstations with various shifts. For this reason, many
extended to suit your needs - and provides investment security for the technical companies around the whole world are using this system for professional
ofce or control centre. computer workstations, control centres, training rooms and user-help-desks,
allover applications where exible, space-saving and future-proof working
environment solutions are required.

118 Lampertz
Compared to traditional ofce furniture systems, the intelligent exploitation Todays exible projects and team compositions require exible environments.
of the available space by Spectro-Data Vision offers up to 60% more usable Tailor-made congurations with a high level of ergonomic quality are achieved
surface ! The individual system components can be adjusted optimally and can by combining the individual modules of Spectro-Data Vision.
be replaced at any time. This allows for an easy adaptation of any workstation
at any time according to its actual user and working environment. Workstation ergonomics thus are an excellent base for highly productive
working without fatigue.

Task console for Facility- and Security Management

SPECTRO-DATA Vision

Industrial Process Control Console

Companies and organisations make their choice out of the


unlimited variability of the kit system, realising their individual
requirements.

Lampertz 119
The system modules for workstation visions
SPECTRO-DATA Vision turns the workstation visions of the IT A modular system with a distinctive image and unlimited advantages.
world into reality.
User-oriented innovation and compatibility with the SPECTRO-DATA Classic
The modular workstation system SPECTRO-DATA from Lampertz has been the defined our targets during the development of the SPECTRO-DATA-Vision. The
classic among professional workstations for many years now. SPECTRO- result is convincing and its extraordinary advantages really make it stand out
DATA-Vision is the logical advancement of SPECTRO-DATA and was consistently from the rest:
designed to meet the demands of technical working environments fascinating Full compatibility with SPECTRO-DATA Classic
system modules which use technical innovations to create completely new work- Optimum economy of office space with height adjustment up to 2095 mm.
station solutions: modular, flexible, economical on space and thus absolutely Ergonomic adjustment to the correct body posture using a fine height
future proof. adjustment feature or power drive height adjustment
Improved surface economy using integrated add-on table tops offers
better variability and quality when designing working environments
Variable cable-management system to be adapted to different amounts of
cables at any time the installation volume can be modified easily

120 Lampertz
Workstation-Systems

SPECTRO-DATA Vision - perfect workstation solutions for technical applications

Optimum design opportunities with the


modular system for:

Production process control consoles

Security control consoles

Trafc and emergency control centres

Network operation and control centres (NOCC)

Console operating

Computer console workstations

Server centres

Manufacturing control consoles

Test and control workstations

Spectro-Data Vision stands for continuous product systema-


tics, ranging from technically-orientated IT-offices and specific
IT-workplaces for console operating, network management or
process control technology, to the pure technical application in
the industry..

SPECTRO-DATA Vision

Lampertz 121
Multi-functional IT-workstations
Productivity by ergonomical monitor Areas of application: Product features: Solution advantages :
integration and the optimum use of
Test and configuration areas Well structured workstations for Custom designed workstations, e.g.,
room and surface space
Research and development testing, checking and developing for testing, checking, developing as
Space-saving Technical IT-office Low office surface costs, increased well as for administrative tasks
Unrestricted positioning IT-back-office economy of available space by its Integration of flat screens on function
possibilities User help desks / call centres multi-level concept profiles and adjustable support arms
Individually adjustable Futureproof adaptability regarding Economical use of space using upper
Arrangement over several levels new hardware generations and levels as well
Perfect cable management display technologies based on the
multi-functional shelf and support
system
Functional secure and adaptable
cabling by the patented cable
management system

Educational and training workstations for helicopter


technicians and pilots

122 Lampertz
IT-Workstations

Standards based on real applications


User help desk workstation:

1 support leg, 720 mm high, asym. foot / 565 mm deep

939,5
1 support leg, 1435 mm high, asym. foot / 565 mm deep
1 support leg, 720 mm high, asym. foot / 705 mm deep

2435
1 support leg, 1435 mm high, asym. foot / 705 mm deep
2 work surfaces 1200 x 800 mm
1 triangular top 90
1 deposit shelf 1200 x 400 mm
1 function prole with lateral xture brackets 1200 mm
required surface: 6,0 m2
2 swivel arms for at screens
2 vertical cable channels, 720 mm
2 vertical cable channels, 1435 mm
1 side cover, 720 mm high for vertical cable channel
1 side cover, 1435 mm high for vertical cable channel
3 exible plastic covers, 720 mm, for vertical cable channel
3 exible plastic covers, 1435 mm, for vertical cable channel
3 horizontal cable channel, 1200 mm
1 horizontal cable channel, 90

Optional
Mobile pedestal cabinet 800 mm deep, 3-6 HU, basic version

Standard configuration and testing double workstation

4 support legs, 720 mm high, asym. foot /


705 mm deep

1813,5
2 foot connectors
2 work surfaces 1600 x 800 mm
1 multi-functional shelf 485 mm, 500 mm deep
2 multi-functional shelves 485mm, 275mm deep
3 monitor clamps
2200
4 vertical cable channel, 720 mm
4 side covers, 720 mm high for vertical required surface: 4,0 m2
cable channel
4 exible plastic covers, 720 mm, for vertical cable channel
2 horizontal cable channel, 1600 mm

Optional
Mobile pedestal cabinet 600 mm deep, 1-3-6 HU, basic version

Multi-level configuration and testing double workstation

4 support legs, 1435 mm high, asym. foot /


705 mm deep
1813,5

2 foot connectors
2 work surfaces 1600 x 800 mm
2 deposit shelves 1600 x 400 mm
3 multi-functional shelves 485 mm, 500 mm deep
SPECTRO-DATA Vision

3 monitor clamps
2200
4 vertical cable channels, 1435 mm
4 side covers, 1435 mm high for vertical channel required surface: 4,0 m2
4 exible plastic covers, 720 mm, for vertical
channel
2 horizontal cable channel, 1600 mm

Optional
Mobile pedestal cabinet 600 mm deep, 1-3-6 HU, basic version

We will gladly advise you on individual


congurations.

Lampertz 123
Control and monitoring consoles
Secure monitoring with a clear Areas of application: Product features: Solution advantages :
arrangement of all monitors and
control elements within optimum Production and process control Optimum workstation ergonomics Complex customized solutions,
visual and operating range Traffic and emergency Electromotive height adjustment economically realized using standard
control centres available on request components
Optimum process control Facility management and Adaptable by its modularity
offering enough space for security monitoring Safe integration of technology
standard hardware and Efficiency and productivity achieved
extensive additional equipment by ergonomic fine tuning

Ergonomically inclined console with cable tray and brush- Installation cabinet for integration of
border protected cable inlet for keyboard and mouse cables standardized 19- equipment or other
hardware, if required with active
ventilation or air-conditioning

124 Lampertz
Control Consoles

Standards based on real applications


Compact control console

2 support legs, 720 mm high, asym. foot /


705 mm deep
1 console work surface 1600 x 900 mm
1 modular installation frame 1600 mm

1838,5
1 function prole 1600 mm
4 angular adapters for TFT at-screen monitors
4 swivel arms for at screens
2 vertical cable channels, 720 mm
2 side covers, 720 mm high for vertical channel
2 exible plastic covers, 720 mm, for vertical channel
1 horizontal cable channel, 1600 mm 1104,5
1 lateral PC support
required surface: 2,0 m2
Optional
Mobile pedestal cabinet 600 mm deep, 1-3-6 HU, basic version

Production control console


with small installation area

2 support legs, 1160 mm high, asym. foot /


705 mm deep
1 work surface 1200 x 800 mm
1 function prole with lateral xture brackets,

1438,5
1200 mm
2 swivel arms for at screens
2 vertical cable channels, 1160 mm
2 side covers, 1160 mm high, for vertical channel
2 exible plastic covers 1160 mm,
for vertical channel
1004,5
1 horizontal cable channel 1200 mm
1 hardware container with 2 doors, 1200 mm required surface: 1,5 m2
1 cover between the vertical cable channels,
1200 mm

Production control console


with large installation area
1716
2 support legs, 720 mm high, asym. foot /
705 mm deep
1 work surface, 1600 x 900 mm
2 foot connectors, 2 vertical cable channels, 720 mm
2 side covers, 720 mm high, for vertical channel
1795

SPECTRO-DATA Vision

2 exible plastic covers 720 mm, for vertical channel


1 horizontal cable channel 1600 mm
1 hardware container 1600 mm with back and front door

required surface: 2,0 m2

We will gladly advise you on individual


congurations.

Lampertz 125
Control console
High-availability by optimal Areas of application: Product features: Solution advantages :
control:
Network operation centre Sturdy multi-level concept Ergonomic arrangement of hardware
Multi-level concept for compact Console operating, IT-centres Space-saving, making economical and other working devices using
highly-integrated screen Test areas use of the area above the work individually adjustable work and
arrangement Computer controlling surface shelving levels
Direct link with 19 network Optimum integration of TFT flat Safe installation of electric and
and server cabinets screen monitors, CRT monitors network cabling according to VDE
Heavy-duty server levels and other peripheral equipment and European standards. Power
on adjustable multi-functional blocks and plug-in sockets are in-
shelves and support systems stalled in large-volume horizontal
and vertical channels

Network Operation Center (NOC) within a Bank Associations data centre Conguration with a 19- system rack easy direct cabling from rack into workstation

126 Lampertz
Control Consoles

Standards based on real applications:


Double level test control console

2 support legs, 1655 mm high, asym. foot /


705 mm deep
1 work surface 1600 x 900 mm

1838,5
1 deposit shelf 1600 x 400 mm
1 keyboard tray 1600 mm
2 vertical cable channels 1655 mm
2 side covers 1655 mm high for vertical channel
2 exible plastic covers 1655 mm, 1104,5

for vertical channel required surface: 2,0 m2


2 horizontal cable channels, 1600 mm

Single level TFT control console

1039,5
2 support legs, 1160 mm high, asym. foot /
705 mm deep
1 work surface, 1600 x 900 mm
1 function prole
with lateral xture brackets 1600 mm

1804
3 swivel arms for at screens
2 vertical cable channels, 1160 mm
2 side covers, 1160 mm, for vertical channel
2 exible plastic covers 1160 mm high for
vertical channel
1 horizontal cable channel, 1600mm, required surface: 1,9 m2

Multi-level network control console

3 support legs, 2095 mm high, asym. foot /


705 mm deep
1 work surface, 2000 x 900 mm
1 work surface, 1600 x 900 mm
1 deposit shelf, 1600 x 400 mm
3953,5

2 function proles with lateral xture brackets, 1600 mm


SPECTRO-DATA Vision

3 function proles with lateral xture brackets, 2000 mm


18 swivel arms for at screens
1 roll-out server shelf, 1600 mm
3 vertical cable channels, 2095 mm
2 side covers, 2095 mm high, for vertical channel 1104,5

4 exible plastic covers, 2095 mm, for vertical channel required surface: 4,4 m2
3 horizontal cable channels, 1600 mm,
standard design
3 horizontal cable channels, 2000 mm,
standard design
1 horizontal cable channel, 1600 mm
1 horizontal cable channel, 2000 mm
1 worktop inll, 900 mm
We will gladly advise you on individual
congurations.

Lampertz 127
Advantages at a glance: exibility investment security - efciency

1. Flexibility investment security 2. Economy of ofce space cost reduction


The system grows according to your requirements step by step. The Variable multi-functional shelving offering flexibly-adjustable height and
extremely high stability allows an easy and vibration-free integration of the angle allow for optimum use of office surface and available space. With
hardware components. SPECTRO-DATA Vision will also meet the demands the height being adjustable up to 2095 mm and by means of the additional
of the next hardware generation and thus offers long-term investment precision height adjustment, the room height is optimally used. The result is
security. up to 60% more usable working and shelving surface.

3. Ergonomics productivity 4. Technology / cable management functional safety


The height of the worksurfaces and deposit shelves can be individually The highest demands on availability placed on todays IT systems can only be
adjusted. Different worksurface depths and intelligent add-on elements met by an integration of technology which is functionally safe. Spectro-Data
allow the system to be optimally adapted to suit different body measure- Vision offers tested safety and complies with the most recent workstation and
ments and work procedures. The ergonomic quality of the workplaces thus safety standards. The modular cable management system can be manually
becomes the basis for productive and fatigue-free work. adapted at any time, not requiring any tools, to suit changing volume require-
ments. It complies with the VDE and European guidelines and easily integrates
power blocks, plug-in sockets and small devices in a safe way.

SPECTRO-DATA Vision turns workstation visions


into reality.
Spectro-Data Vision was consistently designed to meet the demands of tech-
nically-orientated office workstations. This led to the creation of a fascina-
ting modular system kit which allows completely new workstation solu-
tions to be achieved by technical innovations : workstations which are
modular, flexible, economic on space and thus absolutely future proof.

The pacemaker for technical workstation solutions.


High-tech workstations set the highest challenges to a furniture system:
SPECTRO-DATA Vision meets these challenges: the tremendous stability
allows heavy-duty applications; the multi-level concept offers high-density
integration of hardware and other devices using reduced space.
The exemplary cable management ensures proper and safe installations.
And changing team or project structures are easily realized, since the work-
station layouts can be modified without any problems.

128 Lampertz
Advantages

Ergonomics require economical solutions


Modern working environments set the highest demands on the furniture Thus, a unique integration of technology even if only reduced space is
systems used to realize their requirements SPECTRO-DATA Vision is the available - is logically combined with workstation layouts precisely accor-
solution which interlinks efficient workstation organisation with a maxi- ding to your flexible project or team structures..
mum of ergonomic quality.

Lampertz innovative technical workstations use a logical combination of the


SPECTRO-DATA Vision modules creating unique configurations: Tailor-made
configurations, which allow the user to work ergonomically making best
use of the available space.

Let us show you


how Lampertz workstation solutions...

make optimum use of room and surface space


achieve higher productivity by the functional integration of
hardware components
provide functional safety by optimum cable management
quickly adapt to changed hardware
arrange work surfaces ergonomically
easily adapt to changed work-flow

... to create perfect working environments


for our customers.

SPECTRO-DATA Vision

Lampertz 129
Visualisation - keep a clear overview
Really ergonomic: The screen integration.

Flat screens with base can be ergonomically integrated on rear and


upper shelves.

For flat screens (without base or with removable base) with fixing
devices according to VESA-standards, an intelligent support system was
developed which easily allows multi-level solutions too.

Sturdy support arms with integrated cable guide for flat screens allow
the screens to be positioned quickly and individually at any level.

We use different support arm systems to provide you with the best
solution according to your demands.

130 Lampertz
Cable Management System

Perfect cable management system within a system


Integrated connection up to the last bra-
cket. Creating the cable management
system of SPECTRO-DATA Vision, every
detail was considered: Growing cable
channels offering different volumes are
installed vertically and horizontally and
integrate large cable volumes, as well as
power blocks and installation sockets.

This way the cables are guided invisibly


and safely until just before the connected
device. This is proper, functionally safe Simple upgrading without tools
and avoids failures. Free height adjust-
ment and unlimited access from all sides
contribute to the functional safety.

Multi-level cable channels Intelligent networks quick and safe cabling on the open system

SPECTRO-DATA Vision

Vertical cable channel with cable guide Vertical cable channel with lateral cover

Cable channel with rear panel screen Cable channel with installation sockets Cable channel prole system

Lampertz 131
Workstation-Systems

Accessories Intelligent add-ons for man and machine

Practical completion of existing solutions


perfect ne-tuning for the working environment.

SPECTRO-DATA Vision is as individual as its users. A large number of useful make it easy to equip each workstation, individually and tailored to the
equipment options and carefully coordinated fixture & fitting accessories users needs.

Cabinets Mobile pedestal units Server extension units

Lighting Office chairs


Offi h i Shelves/trays

132 Lampertz
Accessories

Multifunctional worktops Hardware cabinets Support arm systems

Cable channels Rack systems Ph


Phone supportt arm

Lampertz provides you with all the necessary and useful workstation
add-ons and integrate themse into an optimum overall solution:

Heavy duty server extension units with safe cable routing Office chairs
Keyboard drawers Filing trays for fixing to the side element
SPECTRO-DATA Vision

Seamless integration of 19 technology from the extensive Telephone swivel arms for fixing to the side element
RITTAL kit-system Partition wall systems for dividing space and as privacy screening
Cabinet systems for documents and working materials Lighting elements
Workstation cabinets as storage space within direct reach Mobile hardware trolleys
Air-conditioning solutions for the hardware integrated in the workplace, Raised flooring
e.g. for dealer workstations Electrical equipment
Mobile pedestal units for personal utensils at the workstation

Lampertz 133
Component overview SPECTRO-DATA Vision

5
1
3
Level III
8
6 7
9
Level II

Level I
4

10
Level 0

Standardized components. Components:


Lampertz counts on SPECTRO-DATA Vision. The modular furniture 1. Support leg
system features a number of properties that are of considerable 2. Work surface
importance for many areas of application. High flexibility for the 3. Deposit shelf
realization of individual configurations, maximum economy of space 4. Roll-out server shelf
due to rational use of surfaces, intelligent cable management 5. Vertical cable channel
for safe cable routing and last but not least standardized 6. Horizontal cable channel
components for economical workstations. 7. Keyboard tray
8. Individual keyboard tray
SPECTRO-DATA Vision therefore provides ideal solutions for 9. Function profile with flat screen arms
every technical application. 10. Lateral CPU support

e.g.: Server centres

6
1 5 3

2
Level III

1
Level II 4

Level I

Example 1 Example 2

Components:
1. Support leg
2. Work surface element, lower level
3. Work surface element, upper lever
4. Roll-out Server shelf
5. Horizontal cable channel
6. Vertical cable channel

134 Lampertz
Working environment design services -
From vision to implementation.

Good advice is not expensive:


Experienced design consultants support you from the project planning
phase to implementation and assist you with advice and realisation of your
workstation visions.

Our workstation specialists draw up individual and precisely detailed layout


drawings based on your wishes and requirements, including 3D-views.

We check...
Your requirement prole
Your specic and current needs
Your premises situation
Which hardware equipment needs to be included

We decide together...
How the new workstation is to be integrated in your environment
Which workows denitely have to be improved
Which add-ons are useful

We design for you...


An optimum solution proposal considering based on the EU Directive
for computer workstations
A detailed quotation and
2D and 3D planning drawings in colour

Ergonomic aspects

VDU work causes substantially more stress on a persons sight as well as Analyses, investigations, etc. repeatedly show that in practice, positioning
on their musculoskeletal and locomotor system than manual office work. of the monitor is one of the greatest weakspots, partly due to the users
The premises should be: VDUs should be positioned so that its user is not ignorance, but partly due to their own creativeness, e.g. positioning it in
forced to adopt an unnatural posture. front of a window.

The adequate viewing distance depends


on the size of the VDU screen its resolu-
tion and contrast. ance
Visua al dist
The following guidance values apply: l distan Visu
ce
17 screen: approx. 60 cm Visual
19 screen: approx. 70 cm Visual angle
SPECTRO-DATA Vision

21" screen: approx. 80 cm angle

Lampertz 135
Friedhelm Loh Group

The Friedhelm Loh Group:

The joint will to succeed

The Friedhelm Loh Group is a dynamic and successful global player, specia-
lising in the invention, development and production of customised products
and system solutions. As well as being the worlds leading manufacturer of
enclosure and case systems and the leading European provider of software
solutions for mechanical and plant engineering and industry, its product
portfolio also includes innovative concepts for the physical protection
of data and IT components (Rittal International), as well as integrated
production expertise with modern materials such as steel, aluminium and
plastic (Lometal International). In the renewable energies sector, the group
offers planning and consultancy services, as well as a full-service package
for cogeneration of heat and power units and photovoltaic systems (Loh
Renewable Energy International).

The joint will to succeed is the driving force behind atarget-oriented


and qualied collaboration between an enthusiastic staff and a manage-
ment that geared towards success. This is the motto that underpins the
companys activities.

136 Lampertz
Friedhelm Loh Group

Global player locally present

The family-owned company employs a workforce of more than 12,600


people in twelve German companies and more than 60 international
subsidiaries. In 2007 the group generated sales exceeding two billion
euros. Complete customer orientation is our guiding philosophy. Creative
solutions, uncompromising quality and rst-class service are our trademarks.
The Friedhelm Loh Group taps into the excellent opportunities afforded by
growth markets and is committed to sustainable international growth. The
companies in the Friedhelm Loh Group have strong roots in their local com-
munities, and make a major contribution to social security. Active environ-
mental protection and ecologically-oriented production structures are rmly
anchored in the corporate principles, one of which is: We are aware of our
responsibility we bear towards the environment and the world in which we
live. We want to take part in shaping and improving it!
Services

Lampertz 137
Security Analysis

LITCOS Integrated Security


The networked world of information technology requires secure system Our basic premise is that sensitive systems are subject to special risks.
functions and an appropriate infrastructure. Due to the complexity of The high availability requirements of data processing call for a range of
modern IT-concepts it takes the skills of an expert to draw up the technical structural and infrastructural measures. Absolute reliability sets the standard
specications for data processing systems, networks and data backup. and this is what LITCOS stands for. We analyse the IT-operations and the
When it comes to physical system design LITCOS GmbH & Co. KG is your security status of your company to the smallest detail. LITCOS analyses the
competent contact. current situation, assesses according to existing standards and proposes
measures based on state-of-the-art technology.

LITCOS plans IT-areas that meet tomorrows security requirements.

138 Lampertz
LITCOS

IT-security check LITCOS offers security based on the experience gained from over 1,600
projects: nancial institutions; local, public, municipal, district and regional
authorities; hospitals; railways; utility companies; logistics rms; telecommu-
nication providers; car manufacturers and their suppliers; the media; publis-
Documentation and archiving check hers; radio; television; manufacturers of machine tools and many more.

Risk analysis of physical environment

Specication manual for IT-room


alteration or construction

Design planning according to HOAI


(Fee Structure for Architects and
Engineers), daily rate basis

Planning and construction monitoring

Risk analysis for organisational


and logical IT-applications

Emergency organisation
Contingency manual

LITCOS GmbH & Co. KG


Daimlerstrae 9
D-57299 Burbach
Phone +49 (0) 27 36 412 34-00
Services

Fax +49 (0) 27 36 412 34-01


http://www.litcos.com
Competent solutions
info@litcos.com

Lampertz 139
Loh Finance

Our Expertise Your Opportunity


Modern leasing and nancing solutions at top conditions for
Friedhelm Loh Group products and services!

Irrespective of whether you are investing in the premium ecological and


economic benets of Wrz Energy systems, for example, or in the exi-bility
and cutting-edge technology of Lampertz physical data security solutions, you
can expect a nancing package for the products and services supplied by the
companies in our Group which is tailored to your individual needs.

Our principle is one-stop shopping which will guarantee your company state-
of-the-art products, forward-looking solutions and a tailor-made nancing
package.

We would be delighted to meet with you in person to illustrate what this


means in concrete terms for you personally!

140 Lampertz
Financing

Your Financing Benets


Is your capital investment project highly ambitious and complex? Would
you like to borrow funds to purchase products? We can steer you towards a
suitable need-driven solution to cater for any event.

You will benet from:

Business exibility
You safeguard your liquidity and conserve your existing credit lines, leaving
you more exibility for major strategic decisions - independent of your prin-
cipal bank.

Financial individuality
The nancing terms are tailored to your individual needs and detailed track
kept of the performance of the project.

Costing condence
You arrange xed payments over the entire term of the agreement, thereby
increasing your cost accounting condence as you are not exposed to any ,EASING%XPENDITUREIN"ILLIONSOF%URO
interest rate risk whatsoever.

Material autonomy
There is normally no need for any securities over and above the asset, such
as land charges.

Accounting neutrality
Depending on the national legal requirements you may have the benet
that you do not have to enter the new asset on the assets side of your
company balance sheet, leaving your equity-to-assets-ratio intact this can
also inuence your corporate rating in positive way. The leasing sector is Germanys largest investor. Leasing is now
higher-ranking than the classic bank loan, especially for small
and medium-sized companies, making it the number-one outside
In Loh Finance you have the support of a reliable and dependable partner financing option. (BDL, Ifo Institute 11/2008)
at your side. Indeed, nobody else is better acquainted with your product or
project requiring nance. We know that your investment is worthwhile!

A Strong Partner A Sound Financial Footing


Loh Finance belongs to the Friedhelm Loh Group, a global player and a Loh Finance works with leading nationwide nance houses and leasing
strong network of companies which design, develop and supply blue-chip companies throughout Germany. Clients from medium-sized companies and
products and services across various sectors of the economy. For more infor- large scale industry across all sectors benet from our comprehensive know-
mation visit www.friedhelm-loh-group.com . how and top conditions.

Benet from the worldwide success of the Friedhelm Loh Group and take Take advantage of the modern, attractive and exible nancing models
advantage of the nancing virtues offered by Loh Finance in cooperation offered by a strong partnership. We will be pleased to answer your
with its partners! individual questions. Contact us by telephone or visit our website at
www.loh-nance.de .
Friedhelm Loh Group Facts and Figures:
Over 12,600 employees worldwide Loh Finance only acts as an intermediary. The performance is delivered by
12 domestic and over 60 foreign companies the respective nancing and leasing company.

Contact address:
Loh Finance
Rudolf Loh Strae 1
D-35708 Haiger
Phone +49(0)27 73 924-33 59
Services

Fax +49(0)27 73 924-38 92


E-Mail: info@loh-nance.de
www.loh-nance.de

Lampertz 141
Notes

For your notes:

Errors and changes reserved


Our general conditions and terms apply
Possible colour variations from the original product are due to printing
Decoration is not part of the scope of delivery
No liability for literal mistakes

142 Lampertz
Terms and Conditions

Standard Terms and Conditions of Sale


1 General Terms
1. The following standard terms and conditions shall govern we shall at our option deliver a replacement or remedy the connection with covering transactions by cheque or promissory
exclusively all contracts between ourselves and the Purchaser. defect. The Purchaser shall grant us a reasonable period of not note.
Any conicting terms and conditions of the Purchaser are here- less than 8 days to carry out the same. 2. The treatment or processing of the reserved property shall be
by revoked, save where we have expressly consented in writing. 3 The Purchaser is entitled to demand reimbursement of the co- carried out for us as the manufacturer within the meaning of
Our standard terms and conditions of business shall further sts incurred by reason of the replacement delivery or remedying 950 of the German Civil Code (BGB) without the incurrence
apply where we supply the Purchaser unconditionally despite of the defect insofar as such costs are not increased due to the of any obligations as a result. In the event that the reserved
being aware of Purchasers conicting terms and conditions. subsequent transportation of the goods delivered to a location property is processed, incorporated in or admixed with objects
2. Our offers are without obligation. Orders and agreements other than the original shipment location unless the purpose which are not our property we shall acquire ownership of the
shall become binding when conrmed by us in writing. The for which the goods are intended requires the same. new object to the extent of the invoice sum for the reserved
same shall apply to business procured by our agents. 4 In the event that we are not in a position to remedy the property. In the event that our title to the goods extinguis-
3. Where contracts are based on trade terms the latter shall be defect or deliver a replacement the Purchaser is entitled to res- hes as a result of incorporation, admixing or processing the
subordinate to these standard terms or other agreements. cind the contract or to demand a reasonable reduction in the Purchaser assigns herewith his proprietary rights or expectant
4. In the event any of the following standard terms and purchase price. Rescission of the contract is only permissible rights in the new object to the invoice value of the reserved
conditions is or becomes invalid, the validity of the remaining where the Purchaser prior thereto sets a nal and reasonable property and and shall hold the same safeguarded for us free
provisions shall remain unaffected, and any such invalid term deadline in writing expressly indicating his intention. of charge. The rights of ownership in common thereby accruing
shall be interpreted or amended in such a way as to reect as 5 The Purchaser shall retain a right or recourse against us shall be regarded as reserved property within the meaning of
far as possible the underlying business aim. within the meaning of 478 of the German Civil Code (BGB) this clause.
2 Price of Goods, Terms of Payment insofar as the Purchaser has not agreed terms with its customer 3. The Purchaser is authorised to resell the reserved property to
1. Our prices are ex works, excluding packing and any statutory which exceed the statutory liability for defects. his usual clientele, in the usual course of business and under
value added tax (VAT). 6 Where the goods are damaged during shipment compliance his usual standard terms and conditions of sale only. The same
2. Conrmed prices shall remain valid for a period of 4 months; with the deadlines set by the shippers insurers is imperative shall apply to a contract for services. Claims by the Purchaser
thereafter the price valid at the date of delivery shall be as a failure to comply will preclude the making of any further against its customers resulting from the resale of the reserved
invoiced insofar as there has been a price increase. The same claim. Where the goods are damaged during shipment the property are assigned herewith to us to the value of our invoice
shall apply in relation to call-off deliveries. Purchaser shall not issue a clean receipt and shall ensure the sum. In the event of resale after processing within the meaning
3. Term of Delivery immediate undertaking of fact nding measures. Any damage of 2 above the Purchaser shall assign its claim arising from
1. The term of delivery shall commence upon receipt of all ascertained shall be notied to us and the shipper without resale to the Seller to the invoice value of the reserved property
documentation required for performance including the timely delay in writing. (Please note that the use of crate openers processed. The assignment shall apply to all surrogate claims in
supply of materials and remittance of payments where appro- when opening open and closed crates and can avoid damage relation to the goods e.g. claims against third parties (insurance
priate. to the content). companies, tortfeasors) for the loss, destruction or damage to
2. In the event that the Purchaser does not cooperate or full 6 Damages the goods.
any secondary obligations in due time we are entitled to extend 1. Liability for damages or expenditure (hereinafter liability 4. The Purchaser is entitled to collect debts from resale until
the term and date of delivery agreed by a reasonable period for damages) irrespective of the legal grounds upon which it we revoke such collection. We shall only revoke when legally
without prejudice to our claims arising from Purchasers default is claimed but in particular for breach of a contractual term justied e.g. in the event of cessation of payments, an applica-
in acceptance. or a tortious act shall be excluded except where we, our legal tion for insolvency pro-
3. The date of dispatch from the works or warehouse is deni- representatives or vicarious agents have acted wilfully or in a ceedings, a protested cheque or bill of exchange, a levy of
tive for determining compliance with the delivery term or date. grossly negligent manner or where the breach goes to the root execution or default in payment. Debts received thereafter to
Where the goods cannot be dispatched on time through no- of the contract. which we are entitled are to be paid into a separate account
fault of our own or are not called off by the Purchaser on time 2. Our liability for a negligent breach which goes to the root of labelled with our rms name. Furthermore the Purchaser is
the term and date of delivery shall be deemed to be complied the contract is limited to reasonably foreseeable damages and obliged to furnish us with all necessary details of the assigned
with upon notication of readiness for shipment. shall not exceed twice the invoice amount. debts and the debtors for the purpose of collection by us. In
4. Where we fail to deliver upon an agreed delivery date and 3. The aforesaid exclusion / limitation of liability shall not apply addition the Purchaser shall provide us with copies of the
such failure is caused by an act or omission on our part the in relation to strict liability claims for death or personal injury relevant documentation (delivery notes, invoices) and inform
Purchaser shall grant us an extension in writing of not less or damage to items of property for personal use under the their debtors of the assignment.
than 2 weeks. Where delivery is still non-forthcoming and the Product Liability or any other strict liability claims. A reversal of 5. The Purchaser is in no circumstances authorised to further
Purchaser desires to rescind the contract or demand damages the burden of proof shall not be implied. pass title, pledge or assign our
in lieu of performance the Purchaser shall prior thereto set a 7 Limitation reserved rights to third parties. The Purchaser shall inform us
nal and reasonable deadline in writing expressly indicating The limitation period for claims based on defective deliveries without delay of any levy of execution which has been or is
his intention. The Purchaser is obliged at our request to de- or performance as well as for claims for damages is 1 year. about to be enforced against our reserved property by third
clare within a reasonable period whether he shall rescind the The limitation period aforesaid shall not apply where longer parties and shall identify our reserved property. Any costs
contract due to the delay in delivery and/or demand damages limitation periods are pre-scribed by law (eg. for structures incurred by us as a result of e.g. intervening are to be paid by
in lieu of performance or insist upon performance. Instalment 438 s.1. No. 2 (BGB), rights of recourse 479 (BGB) and the Purchaser.
deliveries already made are excluded from the aforesaid save building defects 634a s.1 No.2 (BGB)), as well as in cases 6. In the event that the value of the existing securities is in
where they cannot be utilized by the Purchaser. of injury to life, body or health due to wilful or gross negligent excess of more than 20 % of the secured claims we undertake
5. In the event that we or our suppliers are hindered through behaviour on our part and in relation to damage claims based to release the securitiy upon the request of the Purchaser.
an act of god we are entitled to extend the delivery date by on product liability law 7. In the event that the above retention of title clauses are void
an appropriate period. The same shall apply in the event of 8 Terms of Payment or unenforceable according to the law of the state/country in
government intervention, shortages of energy or raw materials, 1. Except where otherwise agreed the Purchaser shall remit which the goods are situtated, the collateral security which
strikes, lockouts, and other unforeseen supply problems, insofar payment of the purchase price within 30 days from the date corresponds to the retention of title in that state/country is
as they are beyond our control. We shall inform the Purchaser of delivery/performance. Upon expiration of the payment term deemed to be agreed. The Purchaser is obliged to undertake
without delay and ensure that any incon- aforesaid the Purchaser shall be deemed in default of payment all necessary steps required to found and maintain comparable
venience for the Purchaser is kept to a minimum. in accordance with 286 sub-paragraph 2, No. 2 of the rights or securities.
4 Shipment, Transfer of Risk German Civil Code (BGB). Where we receive payment within 10 Product Description
1. Risk shall pass to the Purchaser upon the goods leaving the 14 days of the date of invoice we will grant a discount at the The extent of our liability for our product or service particulars
works including where the terms of shipment are freight paid. rate of 2 %. is limited to the terms and conditions set out in each individual
In the event that a delay in shipment occurs through the fault 2. For accomodation systems the terms of payment are as contract. We reserve the right to make technical changes in the
of the Purchaser the risk of damage to or loss of the goods follows: one third upon order conrmation, one third upon course of our product development. Our product descriptions
shall pass to the Purchaser upon notication of readiness for communication to the Purchaser of readiness for shipment and particulars describe the quality of our products and services
shipment. and the nal third upon shipment and/or installation in cash and do not constitute a guarantee within the meaning of 443
2. Minor variations in measurements and workmanship are per- without deduction. of the German Civil Code (BGB).
mitted. In relation to printed matter and plastic articles, which 3. The Purchaser shall not be entitled to withhold or set off The purchaser undertakes to test our products and services
are produced to the Purchasers specication, variations in payments save where its claims are undisputed or have been itself as to their suitability for the purpose intended
quantity of up to 10% in relation to printed matter and 5% in conclusively adjudged by a court of law. 11 Place of Performance / Jurisdiction
relation to plastic articles are also permitted. Allowances shall 4. Cheques and Promissory Notes shall only be accepted as 1. The forum for the institution of proceedings shall be Betzdorf,
be made for delivery excesses or shortages when invoicing. conditional payment. Payment by Promissory Note shall be Germany. We retain the right however to sue before any
3. We shall determine the method of shipment at our discreti- agreed separately. All expenses incurred for Promissory Notes competent court.
on. Postage, freight and, where appropriate, packing, shall be and other charges incurred through payment shall be borne by 2. In as far as the order conrmation does not express other-
invoiced to the Purchaser at cost price. Shipment by road shall the Purchaser and are due for payment immediately. wise, Hof/Westerwald is the place of fullment for all liabilities
be invoiced at our company rate. 9 Retention of Title arising from the contract.
4. Packing is generally non-returnable except where mutually 1. Notwithstanding delivery the property in the goods shall 3. All contracts shall be governed by and construed in accor-
agreed prior to shipment. not pass to the Purchaser until the Purchaser has paid the full dance with German law.
5 Warranty / Product Liability price for all, including future and conditional business transac-
1 The Purchaser can make no claim based on defective delivery tions. This shall apply to claims for the outstanding balance of 08/2005
or performance where the reduced value or merchantability of account, even where the Purchaser has remitted payment for
Services

the goods delivered or services supplied is nominal. individual invoices. The retention of title shall apply until the
2 Where the goods delivered by us are defective and the Purchaser is released completely from contingent liabilities in
Purchaser has properly notied us of the same in writing in particular guarantees or liabilites on promissory notes which
accordance with 377 of the German Commercial Code (HGB) we, in the interest of the Purchaser, have entered into in

Lampertz 143
Lampertz www.security-at-its-best.com

Your IT-security is our business all over the world.

110095800001 02/09