You are on page 1of 20

Manual/Spare part list

Bedienungsanleitung/Ersatzteilliste
Drying tumbler/Wschetrockner T 81 E
INSTRUCTIONS
TUMBLE DRYER T 165 E
Tumbler Dryer T61E & T81E
CAPACITY 6-9 KG DRY LAUNDRY

1. Fill the drum with laundry


2. Close the door properly
3. Choose temperature and program setting
4. Push the program knob to start

Automatic stop Manual time set


Stops when the laundry is dry Stops after the set time
1 Delicate 40/60C 3 Select the temperature and set
2 Perm/Press 40/60C time manually

2
Pern/Press 40/60 40

1 3
Delicate 0 60
Manual
40/60 timeset
70

0/40/60
10

60

20
30 50
40 TEMPERATURE
SETTING
PROGRAM CHOICE
Heat Cooldown

Let always the program finish. Clean the lint filter after usage
Contents
Installation 3
Anchoring of tumble 3
Anchoring of plinth 3
Ventilation 4
Electrical connection 4
Connection of the condenser unit C2 4
Connection of the channel fen 4
Maintenance 4
Condenser Unit C2 4
Important 4

Condenser unit C2 5
Installation 5

Warmth exchanger 5
Installation 5

Changing right door to left door 6

Spare parts 7

Wiring diagram 15

Schematic 16
Schematic 200V~3N 17
Schematic 400V~3N 18
Schematic 440V~3N 19

Exhaust system 18

Measurements 19

3 WESCO 2008
Installation

Anchoring of tumble dryer Ventilation


The tumble dryer has four (4) adjustable feet and can be placed The hose connection of the dryer has a 100 mm. The ventilation
directly on the floor without any extra anchoring. Adjust the channel must be dimensioned for an air quantity of 300 mm3/h.
feet, so that the dryer is horizontal. Check width and depth If several dryers are attached to the same channel, it should
be dimensioned so that the air resistance is the same for all
Anchoring of plinth, 200 mm connected dryers. The ventilation channel should be separated
from other ventilation systems. Connect the dryer to the venti-
Use M8 expander- or anchor bolts when anchoring the plinth. lation channel with a flexible hose.
Minimum size: side 20 mm, back 400 mm.

Electrical connection
The electrical connection must be stationary and must be pre-
pared with an approved allpole head switch, preferable sup-
plied with a signal lamp.

A three-pole 1,5 m2 connecting cable with protective earth


conductor must be used. Main fuse 10 A, voltage 380 V, 3N.

Disconnect the protective sheet plate on the back of the


connection box. Connect phases, null and earth.

Connection of the condenser unit C2


Use a one-phase 220 V, 50 Hz with a cable glander between the
condenser unit and the dryer. Connect the cable through the
cable glander to the connection box on the back of the dryer
Pic. 1
and in to the connection box on the condenser unit.

Assemble the ventilation hoses between the in- and outcoming


air channels on the dryer and condenser unit. Tighten the hoses,
so that they are not hanging under the dryers incoming and
outcoming air connections.

Connecting the channel fan


Connect 220 V, 50 Hz on the back of the dryer to the connection
box. The channel fan is regulated through the dryers timer.

Maintenance
The lint filter, must be cleaned every time the dryer has been
used. Continuos maintenance of the dryer shall be done at least
once every 6 month. Continuos maintenance includes control
Pic. 2 of the dryers different functions and cleaning inside.

Condenser Unit
1. Fasten the plinth in the floor (the blind nuts shall be placed
The warmth exchanger shall be cleaned when necessary.
forward and upwards).
Appropriate interval is once a month. Loosen the frame around
2. Place the dryer on the plinth. Adjust the feet on the bottom the condenser unit and take out the filter and clean it. Then
of the dryer to the plinth, so the dryer is horizontal. Try to carefully take out the dehydrating unit and clean it under run-
keep the feet as low as possible, gives it more stability. ning water. Dont forget to clean the condenser box around the
drain before you put everything back.
3. Loose the lower front plate.
4. Anchor the two M6-bolts that are attached, through the
Important
bottom plate in the front of the plinth. (Pic. 1)
All energy from the condenser unit which are used when drying,
5. Anchor the thin sheet metal at the back, between the plinth gives the surrounding areas a surplus of warmth. It is therefor
and the dryer with attached screw for sheet metal. (Pic. 2) important to have a sufficient ventilation system which handle
. the extra warmth.

WESCO 2008 4
Condenser unit C2 Warmth exchanger

Rek Rek
1400 mm 1400 mm

20 mm 400 mm
20 mm 400 mm

Installation C2 Installation warmth exchanger


The condenser unit is delivered ready for use and shall be The warmth exchanger is delivered ready for use and shall be
assembled on the wall behind or on the side of the dryer. assembled on the wall, behind or on the side of the dryer. The
Ventilation hoses are assembled and condenser water pipes is ventilation hoses are assembled and condenser water pipes
drawn to the floor drain. A separate manual is enclosed about drawn to the floor drain. A separate manual is enclosed about
how to connect incoming air. The condenser unit is connected how to connect incoming air.
electrical via the dryer and is regulated through its start- and If you need an extra channel fan, this can be connected to the
stop functions. connection box 220 V, 50 Hz, regulated via the dryers timer.
The surplus warmth is staying in the drying room. We therefor
strongly recommend a sufficient ventilation.

5 WESCO 2008
Instruction for changing right
door to left door
1. There are 2 hinges (position 5) on the right side of the
door with 2 screws (position 6) each. Please unscrew all
4 screws.

2. Turn the door upside down.

3. Inside the door is a filter cassette that also has to be turned


upside down.

4. On the opposite side of the dooor are 4 holes to install the


2 hinges and the 4 screws again.

This action will take about 10 minutes.

WESCO 2008 6
Spare parts

3
7
4
8
9

Nr Art Nr Description
1 W 56064 Top plate
2 W510212 Fabric selector switch
3 W502964 Timer
4 W56070 Top frame
5 W121025 Transformer 700 VA
6 W510287W Switch knob
7 W7520 Emergency button

7 WESCO 2008
Nr Art Nr Description
1 W510127 Door Striker Bracket
2 W510181 Door Striker
3 W510147 Door Seal
4 W510163 Inner Door Panel and Seal Assembly
5 W505295 Screw
6 W510179 Door Hinge
7 W510066 Front Panel
8 W510103 Door Pull
9 W510013 Outer Door Panel
10 W510129 Wedge

WESCO 2008 8
Nr Art Nr Description
1 W28835 Hold-down Clip
2 W504570 Door Switch
3 W510236 Front Panel Seal
4 W510066 Front Panel
5 W510795 Label
6 W503688 Screw
7 W33562 Slotted Hex Head Screw
8 W510069 Access Panel
9 W56079 Locator
10 W32671 Screw
11 W502804 Label
12 W510177 Door Catch
13 W500281 Label

9 WESCO 2008
Nr Art Nr Description Nr Art Nr Description
1 W510238 Seal 14 W56156 Lock Nut
2 W31260 Screw 15 W510133 Idler Lever
3 W510140 Exhaust Fan Cover 16 W56461 Shaft
4 W510139 Exhaust Fan Impeller 17 W52549 Washer
5 W510138 Exhaust Fan Housing 18 W510142 Idler Pulley
6 W501212 Motor Assembly 19 W23748 Retainer Ring
7 W501218P Motor Switch 20 W500824 Shoulder Bolt
8 W510180 Motor Mounting Clamp 21 W510158 Idler Pulley and lever Assembly
9 W510178 Belt 22 W52566 Lock Nut
10 W500222 Motor Pulley 23 W510060 Motor Mounting Bracket
11 W590P3 Motor Hub Ring Kit 24 W510084 Base
12 W503688 Screw 25 W33561 Screw
13 W510185 Spring 26 W504518 Thermostat

WESCO 2008 10
Nr Art Nr Description
1 W510159 Front Bulkhead
2 W510207 Cylinder Seal
3 W510102 Baffle
4 W510265 Cylinder Assembly
5 W62588 Screw
6 W510002 Cabinet Panel
7 W510187 Cylinder Glide
8 W510145 Glide Bracket
9 W52864 Screw
10 W503688 Screw
11 W501086 Screw
12 W510151 Air Duct Assembly
13 W503980 Lint Filter
14 W510189 Felt Pad
15 W501285 Screw

11 WESCO 2008
Nr Art Nr Description
1 W510207 Cylinder Seal
2 W503688 Screw
3 W505244 Rear Bulkhead
4 W501285 Screw
5 W510237 Shield
6 W510190P Terminal Block
7 W61199 Screw
8 W510025P Heater Assembly
9 W510002 Cabinet
10 W510100 Roller Bracket
11 W510708P Cylinder Roller
12 W56156 Lock Nut
13 W56461 Shaft
14 W504082 Wave Washer
15 W52549 Washer
16 W23748 Retainer Ring

WESCO 2008 12
Nr Art Nr Description
1 W503688 Screw
2 W500820 Outlet Cover
3 W510025P Heater Duct Assembly
4 W510183 Thermal Fuse
5 W23222 Screw
6 W510701 Limit Thermostat
7 W10056 Heater Assembly, 3x1600W 380V

13 WESCO 2008
Nr Art Nr Description
1 W56079 Locator
2 W32671 Screw
3 W56128 Bumper
4 W510005 Cabinet Panel
5 W510136 Top Hinge
6 W503688 Screw
7 W500670 Label
8 W503456 Bracket
9 W510903 Access Cover Plate
10 W501289 Label
11 W510137 Exhaust Duct
12 W510002 Cabinet Panel
13 W510135 Leveling Leg
14 W501855 Rubber Foot
15 W510084 Base
16 W510001 Cabinet Panel

WESCO 2008 14
Wiring diagram

15 WESCO 2008
Schematic

WESCO 2008 16
Schematic 220 V ~3N Schematic 440 V ~3N

Schematic 400 V ~3N

17 WESCO 2008
Exhaust system

WESCO 2008 18
Measurements

19 WESCO 2008
WESCO Navy GmbH, Zitterpappelweg 9, D-22391 HAMBURG
Tel. +49 40 536 00 61, Fax +49 40 536 75 01, e-mail info@wesco-navy.com

WESCO 2008-12-09