ALL STAINLESS STEEL PRESSURE GAUGES

111 series

APPLICATIONS
Used with all liquid and gas process media, provided that these do not
corrode stainless steel, do not crystallize and are not highly viscous. The
glycerin / silicon oil filled type is especially used for measuring points subject
to vibration and highly dynamic pressure load. Particularly used in chemical,
petrochemical, food industry, biochemistry and any rush industries.

SPECIFICATIONS
Dial diameter 1 (40mm) ; 2 (50mm) ; 2 (63mm) ; 3 (75mm) ; 4 (100mm) ; 6 (150mm)
Stainless steel 304, IP65
Case
Crimp bezel for dial 1 ~ 4 ; Bayonet bezel for dial 2 ~ 6
Lens Acrylic or glass for dial 1 ~ 4 ; Safety glass for dial 4 and 6

Dial Aluminum, black and red markings on white background, dial arc 270
Bourdon Tube, stainless steel 316
Measuring principle
C form tube for 70 kg/cm2 ; Helical form tube for >70 kg/cm2
Movement Stainless steel

Pointer Aluminum, black, adjustable pointer available for dial 4 and 6

Connection Male thread 1/8, 1/4, 3/8, 1/2 PT(BSPT) / NPT / PF(BSP), stainless steel 316

Filling Without (dry) ; glycerin filled ; silicon oil filled

Accuracy 2% F.S. for 1 & 2 ; 1.5% F.S. for 2 & 3 ; 1% F.S. for 4 & 6
Drymedium +200 ; ambient -20 to +60
Glycerin filled: medium +60 ; ambient +10 to +60
Temperature limits Silicon oil filled: medium +100 ; ambient -45 to +60
Silicon oil filled type can be for medium +200 only if the case and connection
are welded together (argon-arc welding), available for2 & 4 & 6.
positive 0 / 1 ~ 0 / 1000 kg/cm2
negative 0 / -76 cmHg (relative vacuum)
Ranges
compound -76cmHg / 0 / 1 ~ -76cmHg / 0 / 20 kg/cm2
other units available, e.g. psi, bar, MPaetc.

OPTIONS
Safety glass lens for dial 2-1/2 & 3
Blow-out disk by back for dial 4
Special male or female thread connections
Cleanness for oxygen, acetylene, hydrogenetc. dangerous media service
Restrictor on connection to alleviate pressure pulsation
Device of red pointer which can leave behind on max. pressure
Device of diaphragm, electrical contacts or accessories
MOUNTING TYPES AND DIAL SIZES

TYPE B TYPE W TYPE D TYPE DE

Dial 1, 2, 2, Dial 2, 3, 4, 6 Dial 1, 2, 2, Dial 2, 4, 6


3, 4, 6 Surface mounting 3, 4, 6 Direct mounting
Direct mounting Bottom connection Direct mounting Eccentric back
Bottom connection with back flange Centric back connection
without flange (Wall mounting) connection without flange

TYPE P TYPE PE TYPE U

Dial 1, 2, 2 Dial 4
Dial 2, 2, 3, Dial 2, 4, 6
4, 6 Flush panel mounting Flush panel mounting
Flush panel mounting Eccentric back Centric back connection with U-clamp
Centric back connection
connection with front flange

STANDARD CONNECTION
Dial diameter Thread size Dial diameter Thread size
1 1/8 3 3/8
2 1/4 4 1/2
2 1/4 6 1/2
Thread specification PT (=BSPT) ; NPT ; PF (=BSP) ; others

Custom-made connection available upon request

HOW TO ORDER
(Please specify additionally the special custom-made specifications or option items)

Example: 111 L B 40 4 P 0/10 kg/cm2

Mounting Type Range Unit


Filling B bottom Dial Size Thread
L glycerin W surface (wall) 15 1 Size Thread
S silicon oil D centric back 20 2 1 1/8 Spec.
N use no oil DE eccentric back 25 2 2 1/4 P PT (BSPT)
O without filling P panel-centric back 30 3 3 3/8 N NPT
PE panel-eccentric back 40 4 4 1/2 F PF (BSP)
U panel-U clamp 60 6 0 others O others
STAINLESS STEEL CASE PRESSURE GAUGES
112 series

APPLICATIONS
Used with the liquid and gas process media not corrosive, not
crystallizing and not highly viscous. The glycerin / silicon oil filled
type is especially used for measuring points subject to vibration and
highly dynamic pressure load. Particularly used in hydraulics,
compressors, general mechanical engineering, pumps, water
treatment plants, etc.

SPECIFICATIONS
Dial diameter 1 (40mm) ; 2 (50mm) ; 2 (63mm) ; 3 (75mm) ; 4 (100mm) ; 6 (150mm)
Stainless steel 304, IP65
Case
Crimp bezel for dial 1 ~ 4 ; Bayonet bezel for dial 2 ~ 6
Lens Acrylic or glass for dial 1 ~ 4 ; Safety glass for dial 4 and 6

Dial Aluminum, black and red markings on white background, dial arc 270
Bourdon Tube, brass
Measuring principle
C form tube for 70 kg/cm2 ; Helical form tube for >70 kg/cm2
Movement Brass

Pointer Aluminum, black, adjustable pointer available for dial 4 and 6

Connection Male thread 1/8, 1/4, 3/8, 1/2 PT(BSPT) / NPT / PF(BSP), brass

Filling Without (dry) ; glycerin filled ; silicon oil filled

Accuracy 2% F.S. for 1 & 2 ; 1.5% F.S. for 2 ~ 6


Dry:medium +60 ; ambient -20 to +60
Glycerin filled: medium +60 ; ambient +10 to +60
Temperature limits Silicon oil filled: medium +60 ; ambient -45 to +60
Available for medium +180 if the bourdon tube is silver soldered. This is
special custom-made type upon request.
positive 0 / 1 ~ 0 / 1000 kg/cm2
negative 0 / -76 cmHg (relative vacuum)
Ranges
compound -76cmHg / 0 / 1 ~ -76cmHg / 0 / 20 kg/cm2
other units available, e.g. psi, bar, MPaetc.

OPTIONS
Safety glass lens for dial 2-1/2 & 3
Blow-out disk by back for dial 4
Special male or female thread connections
Cleanness for oxygen, acetylene, hydrogenetc. dangerous media service
Restrictor on connection to alleviate pressure pulsation
Device of red pointer which can leave behind on max. pressure
Device of diaphragm, electrical contacts or accessories
MOUNTING TYPES AND DIAL SIZES

TYPE B TYPE W TYPE D TYPE DE

Dial 1, 2, 2, Dial 2, 3, 4, 6 Dial 1, 2, 2, Dial 2, 4, 6


3, 4, 6 Surface mounting 3, 4, 6 Direct mounting
Direct mounting Bottom connection Direct mounting Eccentric back
Bottom connection with back flange Centric back connection
without flange (Wall mounting) connection without flange

TYPE P TYPE PE TYPE U

Dial 2, 2, 3, Dial 2, 4, 6 Dial 1, 2, 2 Dial 4


4, 6 Flush panel mounting
Flush panel mounting Eccentric back
Flush panel mounting
Centric back connection
connection with front flange Centric back connection with U-clamp

STANDARD CONNECTION
Dial diameter Thread size Dial diameter Thread size
1 1/8 3 3/8
2 1/4 4 1/2 ; 3/8
2 1/4 6 1/2
Thread specification PT (=BSPT) ; NPT ; PF (=BSP) ; others

Custom-made connection available upon request

HOW TO ORDER
(Please specify additionally the special custom-made specifications or option items)

Example: 112 L B 40 4 P 0/10 kg/cm2

Mounting Type Range Unit


Filling B bottom Dial Size Thread
L glycerin W surface (wall) 15 1 Size Thread
S silicon oil D centric back 20 2 1 1/8 Spec.
N use no oil DE eccentric back 25 2 2 1/4 P PT (BSPT)
O without filling P panel-centric back 30 3 3 3/8 N NPT
PE panel-eccentric back 40 4 4 1/2 F PF (BSP)
U panel-U clamp 60 6 0 others O others