You are on page 1of 94

U SER G UIDE

WIMAX 802.16E INDOOR CPE


PointMAX 3000
PointMAX 3000V
U SER G UIDE

POINTMAX 3000
POINTMAX 3000V
WiMAX IEEE 802.16e Indoor CPE

PointMAX 3000
PointMAX 3000V
E122009-CS-R01
149100000076W
COMPLIANCES

FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT


This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to


which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the


party responsible for compliance could void the user's authority to operate
this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

IMPORTANT NOTE: This equipment complies with FCC radiation exposure limits set forth for an
FCC RADIATION uncontrolled environment. This equipment should be installed and
EXPOSURE STATEMENT operated with minimum distance 20cm between the radiator & your body.

This transmitter must not be co-located or operating in conjunction with


any other antenna or transmitter.

Due to the essential high output power natural of WiMAX device, use of this
device with other transmitter at the same time may exceed the FCC RF
exposure limit and such usage must be prohibited (unless such co-
transmission has been approved by FCC in the future).

3
COMPLIANCES

EC CONFORMANCE Marking by the above symbol indicates compliance with the Essential
DECLARATION Requirements of the R&TTE Directive of the European Union (1999/5/EC).
This equipment meets the following conformance standards:

EN 60950-1 (IEC 60950-1) - Product Safety

EN 301 489-1, EN 301 489-4 - EMC requirements for radio equipment

EN 302 326-1-2-3

EN 50385 - Country specific SAR requirements

This device is intended for use in all European Community countries.

4
ABOUT THIS GUIDE

PURPOSE This guide gives specific information on how to install the WiMAX Indoor
CPE (Consumer Premise Equipment, from herein CPE) and its physical and
performance related characteristics. It also gives information on how to
operate and use the management functions of the CPE.

AUDIENCE This guide is intended for use by network administrators who are
responsible for installing, operating, and maintaining network equipment;
consequently, it assumes a basic working knowledge of LANs (Local Area
Networks), the Internet Protocol (IP), and Simple Network Management
Protocol (SNMP).

CONVENTIONS The following conventions are used throughout this guide to show
information:

NOTE: Emphasizes important information or calls your attention to related


features or instructions.

CAUTION: Alerts you to a potential hazard that could cause loss of data, or
damage the system or equipment.

WARNING: Alerts you to a potential hazard that could cause personal injury.

RELATED PUBLICATIONS As part of the CPEs software, there is an online web-based help that
describes all management related features.

REVISION HISTORY This section summarizes the changes in each revision of this guide.

DECEMBER 2009 REVISION


This is the first revision of this guide. It is valid for software version
0.0.8.1.

5
ABOUT THIS GUIDE

6
CONTENTS

COMPLIANCES 3

ABOUT THIS GUIDE 5

CONTENTS 7

FIGURES 11

TABLES 13

SECTION I GETTING STARTED 15

1 INTRODUCTION 17
Key Hardware Features 17
Package Contents 18
Hardware Description 19
Antennas 21
LED Indicators 22
Ethernet Ports 23
VoIP Phone Ports 23
Power Connector 23
Reset Button 23

2 INSTALLING THE POINTMAX 3000 25


Location Selection 25
Mounting on a Horizontal Surface 26
Mounting on a Wall 27
Cable Connections 28

3 INITIAL CONFIGURATION 31
Connecting to the Login Page 31
Home Page and Main Menu 32

7
CONTENTS

SECTION II WEB CONFIGURATION 33

4 SYSTEM SETTINGS 35
WAN Settings 35
LAN Settings 37
SNTP 38

5 WIMAX SETTINGS 41
Frequency Scanning 42
Scanning Table 42
Link Quality Counters 43
Ethernet On-Line Counters 44

6 SECURITY SETTINGS 47
User Registration 47

7 NAT SETTINGS 49
Network Address Translation 49
Virtual Server 49
Demilitarized Zone (DMZ) 51

8 FIREWALL SETTINGS 53
Firewall Settings 53
Port Filter 54

9 MANAGEMENT SETTINGS 55
Resetting the Unit 55
Changing the Access Password 56
Firmware Upgrade 56
Configuration Control 57
SNMP 58

10 VOIP SETTINGS (POINTMAX 3000V) 59


Enabling VoIP 60
SIP Account 60
SIP Setting 61
Dial Plan 61
Call Feature 63
Phone Setting 63

8
CONTENTS

11 STATUS 65
System Status 66
Radio 68
Registration Parameters 68
System Log 69

12 LOGOUT 71
Logging Out 71

SECTION III APPENDICES 73

A TROUBLESHOOTING 75
Diagnosing LED Indicators 75
Before Contacting Technical Support 75

B HARDWARE SPECIFICATIONS 77
WiMAX Radio Specifications 77
VoIP Specifcations 78
Configuration and Management 79
Mechanical 79
Electrical 80
Environmental 80
Standards Compliance 80

C CABLES AND PINOUTS 83


Twisted-Pair Cable Assignments 83
10/100BASE-TX Pin Assignments 83
Straight-Through Wiring 84
Crossover Wiring 84

GLOSSARY 87

INDEX 91

9
CONTENTS

10
FIGURES

Figure 1: Top Panel 19


Figure 2: Rear Panel - PointMAX 3000 20
Figure 3: Rear Panel - PointMAX 3000V 21
Figure 4: LEDs 22
Figure 5: Anti-slip Feet 26
Figure 6: Wall Mounting 27
Figure 7: Connecting the PointMAX 3000V 28
Figure 8: Login Page 31
Figure 9: Home Page PointMAX 3000 32
Figure 10: Home Page PointMAX 3000V 32
Figure 11: WAN Settings - Dynamic 35
Figure 12: WAN Settings - Static 36
Figure 13: LAN Settings 37
Figure 14: SNTP Settings 38
Figure 15: Scanning Table 42
Figure 16: Link Quality Counters 43
Figure 17: Ethernet Counters 44
Figure 18: User Registration 47
Figure 19: Network Address Translation 49
Figure 20: Virtual Server 50
Figure 21: DMZ 51
Figure 22: Firewall Settings 53
Figure 23: Port Filter 54
Figure 24: Reset Unit 55
Figure 25: Change Password 56
Figure 26: Firmware Upgrade 56
Figure 27: Configuration Control 57
Figure 28: SNMP 58
Figure 29: Enabling VoIP 60
Figure 30: SIP Account Settings 60
Figure 31: SIP Settings 61

11
FIGURES

Figure 32: Dial Plan Settings 62


Figure 33: Call Features 63
Figure 34: Phone Settings 64
Figure 35: Show All 66
Figure 36: Radio Settings 68
Figure 37: Registration 68
Figure 38: Registration 69
Figure 39: Logout 71
Figure 40: Login 71
Figure 41: RJ-45 Connector 83
Figure 42: Straight Through Wiring 84
Figure 43: Crossover Wiring 85

12
TABLES

Table 1: Key Hardware Features 17


Table 2: LED Behavior 22
Table 3: Dial Plan Elements 62
Table 4: VoIP Call Features 63
Table 5: LED Indicators 75
Table 6: 10/100BASE-TX MDI and MDI-X Port Pinouts 84

13
TABLES

14
SECTION I
GETTING STARTED

This section provides an overview of the WiMAX CPE, and introduces some
basic concepts about wireless networking. It also describes the basic
settings required to access the management interface.

This section includes these chapters:

Introduction on page 17

Installing the PointMAX 3000 on page 25

Initial Configuration on page 31

15
SECTION | Getting Started

16
1 INTRODUCTION

The PointMAX 3000 and PointMAX 3000V CPEs are 2.5 GHz indoor
WiMAX IEEE 802.16e CPEs that include either an RJ-45 LAN port and two
RJ-11 phone ports, or just a single RJ-45 LAN port. The CPEs are WiMAX
wireless access subscriber stations with a built-in high-capacity Internet
gateway, ideal for a home or small office. Each system provides network
connections that are always on, supporting immediate access to the
Internet and other IP services at high data rates. The unit provides a
gateway function between a WiMAX service provider and a local Ethernet
LAN. The device enables a service provider to deliver last mile broadband
wireless access as an alternative to wired DSL or cable modems.

With a range of up to 5 Km and lower equipment and deployment costs,


PointMAX 3000 CPEs enable service providers to wirelessly extend their
services to customers in areas where the cost of cabling is prohibitive to
deployment. Remote residential areas can now benefit from high-speed
wireless Internet access, Web browsing and e-mail, and advanced
applications such as multi-media services.

The PointMAX 3000 CPEs are plug-and-play devices that provide a


network interface through an RJ-45 Ethernet switch port, as well as two
RJ-11 Voice over IP (VoIP) phone ports for telecommunications.

KEY HARDWARE FEATURES


The following table describes the main hardware features of the CPEs.

Table 1: Key Hardware Features

Frequency Band Model Number Description

2.5 PointMAX 3000V One 10/100-BASE-TX RJ45 LAN port,


and two RJ-11 phone ports.

2.5 PointMAX 3000 One 10/100-BASE-TX RJ-45 LAN port.

The PointMAX 3000 CPEs offer a user-friendly web-based management


interface for the configuration of all the units features. Any PC directly
attached to the unit can access the management interface using a web
browser, such as Internet Explorer (version 6.0 or above) or Firefox
(version 1.5 or above).

The initial configuration steps can be made through the web browser
interface using the Setup Wizard. It is recommended to make the initial
changes by connecting a PC directly the devices LAN port.

17
CHAPTER 1 | Introduction
Package Contents

PACKAGE CONTENTS
The PointMAX 3000 package includes:

The PointWiMAX 3000 or PointWiMAX 3000V Indoor CPE

AC power adapter

Quick Installation Guide

User Guide CD

Two external dipole antennas

Inform your dealer if there are any incorrect, missing or damaged parts. If
possible,retain the carton, including the original packing materials. Use
them again to repack the product in case there is a need to return it.

18
CHAPTER 1 | Introduction
Hardware Description

HARDWARE DESCRIPTION
Figure 1: Top Panel
Antennas

LED Indicators

19
CHAPTER 1 | Introduction
Hardware Description

Figure 2: Rear Panel - PointMAX 3000

RJ-45 Port DC Power Socket Reset Button

20
CHAPTER 1 | Introduction
Hardware Description

Figure 3: Rear Panel - PointMAX 3000V

RJ-45 Port Reset Button

RJ-11 Phone Ports DC Power Socket

ANTENNAS Two omnidirectional antennas are included with the PointMAX 3000 for
WiMAX communications. The omnidirectional antennas transmit and
receive signals in all directions equally.

21
CHAPTER 1 | Introduction
Hardware Description

LED INDICATORS The PointMAX 3000 includes an array of status LED indicators, as
described in the following figure and table.

Figure 4: LEDs

Power LAN VoIP WiMAX Signal


Link/Activity Strength Indicators

Table 2: LED Behavior

LED Status Description

Power Off The CPE has no power.

Amber/Red/Green The CPE is power cycling.


(simultaneous)

Red The CPE has encountered a critical error.

Flashing Orange The CPE is resetting to its factory defaults.

Flashing Amber Authentication between the CPE and the base-station


has failed.

Flashing Green Authentication between the CPE and the base-station


has timed out.

Green The CPE has a valid connection with a base-station and


has authenticated.

LAN Off Ethernet RJ-45 has no valid link.

Flashing Blue Ethernet RJ-45 has a link. Blinking indicates network


activity.

Blue Ethernet RJ-45 has a valid link, but there is no network


activity.

VoIP Off The VoIP function is disabled.

Blue The VoIP function is enabled.

22
CHAPTER 1 | Introduction
Hardware Description

Table 2: LED Behavior (Continued)

LED Status Description

WiMAX Signal Flashing Blue The CPE is power cycling.


Strength
(7 LEDs) 1~7 On Blue The CPE is receiving a full-strength WiMAX signal from a
transmitting base station.

2~6 On Blue The CPE is receiving a reduced-strength WiMAX signal


from a transmitting base station.

1 On Blue The CPE is receiving a low-strength WiMAX signal from a


transmitting base station.

ETHERNET PORTS The unit has one to four 10/100-BASE-TX RJ-45 ports (depending on
model) that can be attached directly to 10BASE-T/100BASE-TX LAN
segment.

This port supports automatic MDI/MDI-X operation, so you can use


straight-through cables for all network connections to PCs, switches, or
hubs.

The unit appears as an Ethernet node and performs a bridging function by


moving packets from the wired LAN to remote workstations on the wireless
infrastructure.

VOIP PHONE PORTS The PointMAX provides a maximum of two RJ-11 telephone ports that
connect directly to a standard (analog) telephone set. This allows a regular
telephone to be used for making VoIP calls over the Internet.

POWER CONNECTOR The unit does not have a power switch. It is powered on when connected to
the AC power adapter, and the power adapter is connected to a power
source. The power adapter automatically adjusts to any voltage between
100~240 volts at 50 or 60 Hz, and supplies 12 volts DC power to the unit.
No voltage range settings are required.

RESET BUTTON This button can be used to restart the PointMAX 3000.

23
CHAPTER 1 | Introduction
Hardware Description

24
2 INSTALLING THE POINTMAX 3000

This chapter describes how to install the PointMAX 3000.

LOCATION SELECTION
Choose a proper place for the PointMAX 3000. For optimum performance,
consider these guidelines:

Select a cool, dry place, which is out of direct sunlight.

The device should have adequate space (approximately two inches) on


all sides for proper air flow.

The device must be near an AC power outlet that provides 100 to 240
V, 50 to 60 Hz.

The device should be accessible for network cabling and allow the
status LED indicators to be clearly visible.

Avoid mounting next to or near building support columns or other


obstructions that may cause reduced signal or null zones in parts of the
coverage area.

Mount away from any signal absorbing or reflecting structures (such as


those containing metal).

The PointMAX 3000 can be mounted on any horizontal surface, or a wall.

NOTE: If the WiMAX Indoor CPE displays a weak WiMAX receive signal, try
moving it to another location.

25
CHAPTER 2 | Installing the PointMAX 3000
Mounting on a Horizontal Surface

MOUNTING ON A HORIZONTAL SURFACE


To keep the PointMAX 3000 from sliding on the surface, the unit is
provided with four attached rubber feet.

Figure 5: Anti-slip Feet

Rubber Feet

26
CHAPTER 2 | Installing the PointMAX 3000
Mounting on a Wall

MOUNTING ON A WALL
To mount on a wall, follow the instructions below.

Figure 6: Wall Mounting

Mounting Slots

The PointMAX 3000 should be mounted only to a wall or wood surface


that is at least 1/2-inch plywood or its equivalent. To mount the
PointMAX 3000 on a wall, always use its wall-mounting slots.

1. Mark the position of the two screw holes on the wall. For concrete or
brick walls, you will need to drill holes and insert wall plugs for the
screws.

2. Insert two 20-mm M4 tap screws into the holes, leaving about 2-3 mm
clearance from the wall.

3. Line up the two mounting points on the CPE with the screws in the wall,
then slide the AP down onto the screws until it is in a secured position.

27
CHAPTER 2 | Installing the PointMAX 3000
Cable Connections

CABLE CONNECTIONS
The PointMAX 3000 is a plug-and-play device, so once it has been
connected to your PC and powered up, it is fully operable.

Functioning as a gateway, the unit routes traffic between a WiMAX network


and PCs or notebooks in the local network.

Figure 7: Connecting the PointMAX 3000V

TO CONNECT THE POINTMAX 3000:


1. Power on the PointMAX 3000 by connecting the AC power adapter
and plugging it into an AC power source.

CAUTION: Use ONLY the power adapter supplied with the PointMAX3000.
Otherwise, the product may be damaged.

2. Observe the indicator LEDs. When you power on the PointMAX 3000,
verify that the Power LED turns on and that the other LED indicators
start functioning as described under LED Indicators on page 22.

28
CHAPTER 2 | Installing the PointMAX 3000
Cable Connections

3. Connect Category 5 or better Ethernet cables from the


PointMAX 3000s LAN ports to the network ports of your PCs.
Alternatively, you can connect the LAN ports to an Ethernet switch or
other devices. Make sure the length of each cable does not exceed 100
meters (328 ft).

4. If your PCs are powered on, the RJ-45 LAN port LED on the
PointMAX 3000 should turn on to indicate valid links.

5. (Optional for PointMAX 3000V.) Connect one or two standard (analog)


telephone sets to the PointMAX 3000Vs VoIP ports using standard
telephone cable with RJ-11 plugs. The PointMAX 3000V enables VoIP
calls to be made through the unit using a standard (analog) telephone
set connected to a VoIP port, or from PCs or other network devices
connected to the LAN ports. Standard Session Initiation Protocol (SIP)
technology is used to make VoIP calls. You must access the web
interface and configure settings for your SIP service provider before
you can make VoIP calls.

6. Use your PCs web browser to access the units management interface
and run the Setup Wizard to make any configuration changes.

NOTE: The RJ-45 ports on the PointMAX 3000 supports automatic MDI/
MDI-X operation, so you can use straight-through cables for all network
connections to PCs, switches, or hubs.

29
CHAPTER 2 | Installing the PointMAX 3000
Cable Connections

30
3 INITIAL CONFIGURATION

The PointMAX 3000 offers a user-friendly web-based management


interface for the configuration of all the units features. Any PC directly
attached to the unit can access the management interface using a web
browser, such as Internet Explorer (version 6.0 or above) or Firefox
(version 2.0 or above).

CONNECTING TO THE LOGIN PAGE


It is recommended to make initial configuration changes by connecting a
PC directly to the PointMAX 3000s LAN port. The PointMAX 3000 has a
default IP address of 192.168.254.251 and a subnet mask of
255.255.255.0. You must set your PC IP address to be on the same subnet
as the PointMAX (that is, the PC and PointMAX 3000 addresses must both
start 192.168.254.x).

To access the CPE management interface, follow these steps:

1. Use your web browser to connect to the management interface using


the default IP address of 192.168.254.251.

2. Log into the interface by entering the default password installer, then
click Login.

NOTE: It is strongly recommended to change the default user name and


password the first time you access the web interface. For information on
changing user names and passwords, See System Settings on page 35.

Figure 8: Login Page

31
CHAPTER 3 | Initial Configuration
Home Page and Main Menu

HOME PAGE AND MAIN MENU


After logging in to the web interface, the Home page displays. The Home
page shows some basic settings for the CPE, including Country Code and
the management access password.

Figure 9: Home Page PointMAX 3000

Figure 10: Home Page PointMAX 3000V

The web interface Main Menu menu provides access to all the configuration
settings available for the CPE.

32
SECTION II
WEB CONFIGURATION

This section provides details on configuring the CPE using the web browser
interface.

This section includes these chapters:

System Settings on page 35

WiMAX Settings on page 41

Security Settings on page 47

NAT Settings on page 49

Firewall Settings on page 53

Management Settings on page 55

Status on page 65

Logout on page 71

33
SECTION | Web Configuration

34
4 SYSTEM SETTINGS

This chapter describes basic system settings on the CPE. It includes the
following sections:

WAN Settings on page 35

LAN Settings on page 37

SNTP on page 38

The System page configures some basic settings for the CPE, such as the
WAN, LAN SNTP and Ethernet Mode settings.

WAN SETTINGS
By default, the CPE will be automatically configured with IP settings from a
Dynamic Host Configuration Protocol (DHCP) server.

Figure 11: WAN Settings - Dynamic

35
CHAPTER 4 | System Settings
WAN Settings

Figure 12: WAN Settings - Static

The following items are displayed on these pages:

Connection Type Specifies dynamic or static connection to the


wireless WAN port.

IP Address Specifies an IP address for wireless management of the


CPE. Valid IP addresses consist of four decimal numbers, 0 to 255,
separated by periods. (Default: 192.168.0.100.)

Subnet Mask Indicates the local subnet mask. (Default:


255.255.255.0)

Gateway The default gateway is the IP address of the router for the
CPE, which is used if the requested destination address is not on the
local subnet. (Default: 192.168.0.254)

36
CHAPTER 4 | System Settings
LAN Settings

LAN SETTINGS
Configuring the CPE with a LAN IP address range enables you to connect
various network devices to the routing capabilities of the PointMAX 3000.

Figure 13: LAN Settings

The following items are displayed on this page:

IP Address Specifies an IP address for connection to the CPE. Valid


IP addresses consist of four decimal numbers, 0 to 255, separated by
periods. (Default: 192.168.254.251.)

Subnet Mask Indicates the local subnet mask.


(Default: 255.255.255.0)

DHCP Server Enables the DHCP server function.

IP Pool Starting Address Specifies the starting IP address of the


DHCP server address pool.

IP Pool Ending Address Specifies the ending IP address of the


DHCP server address pool.

Lease Time Specifies a lease time for usage of the specified DHCP
Server settings. (Default: One day; Range: Half hour, One hour, Two
hours, Half day, One day, Two days, One week, Two weeks)

37
CHAPTER 4 | System Settings
SNTP

SNTP
Simple Network Time Protocol (SNTP) allows the CPE to set its internal
clock based on periodic updates from a time server (SNTP or NTP).
Maintaining an accurate time on the CPE enables the system log to record
meaningful dates and times for event entries. If the clock is not set, the
CPE will only record the time from the factory default set at the last
bootup.

The CPE acts as an SNTP client, periodically sending time synchronization


requests to specific time servers. You can configure up to two time server
IP addresses. The CPE will attempt to poll each server in the configured
sequence.

Figure 14: SNTP Settings

The following items are displayed on this page:

NTP Configures the CPE to operate as an SNTP client.


(Default: Enabled)

NTP Server IP Address The IP address of an SNTP or NTP time


server that the CPE attempts to poll for a time update.

Update Period The interval at which the client sends a time update
request to the SNTP or NTP server.

Time Zone SNTP uses Greenwich Mean Time, or GMT (sometimes


referred to as Coordinated Universal Time, or UTC) based on the time
at the Earths prime meridian, zero degrees longitude. To display a time
corresponding to your local time, you must indicate the number of
hours your time zone is located before (east) or after (west) GMT.

Select from the scroll down list the locale you are situated most close

38
CHAPTER 4 | System Settings
SNTP

to, for example for New York, select (GMT-05) Eastern Time (US &
Canada).

39
CHAPTER 4 | System Settings
SNTP

40
5 WIMAX SETTINGS

This chapter describes WiMAX management settings on the CPE. It includes


the following sections:

Frequency Scanning on page 42

Link Quality Counters on page 43

Ethernet On-Line Counters on page 44

41
CHAPTER 5 | WiMAX Settings
Frequency Scanning

FREQUENCY SCANNING
Frequency Scanning allows the user to enter frequencies with which to
scan for nearby base stations.

SCANNING TABLE The Scanning Table displays all frequencies and bandwidths scanned by the
CPE.

Figure 15: Scanning Table

The following items are displayed on the Scanning Table page:

Rx Frequency(MHz) Describes the receive frequency scanned.

Bandwidth Describes the receive bandwidth scanned.

BEST BS SCANNING TABLE LIST The Scanning Table List allows the
user to update the scanning table, clear the best AU table and force full
scanning.

42
CHAPTER 5 | WiMAX Settings
Link Quality Counters

BS ID Describes the number used to uniquely identify the base


station identity.

Rx Frequency(MHz) Describes the received signal frequency band.

SNR(dB) Describes the signal-to-noise ratio of the received signal.

Bandwidth Describes the bandwidth of the received signal.

Update Scanning Table Updates the scanning table.

Clear Best AU Table Clears the table.

Force Full Scanning Forces scanning on all frequencies.

LINK QUALITY COUNTERS


The Link Quality On-Line Display page displays the SNR (signal to noise
ratio), RSSI (receive signal strength indication), and Tx/Rx data levels.

Figure 16: Link Quality Counters

ONLINE LINK QUALITY The Link Quality On-Line Display table


displays read-only information related to the quality of the link between
the CPE and the base station.

The following items are displayed on the Link Quality On-line Display page:

Current Fec Code Displays the current FEC code.

CINR (dB) Displays the median level of the downlink (DL) Carrier-
to-Interference and Signal-to-Noise (SNR) ratio, measured over a
duration of two seconds. The figure will refresh every two seconds.

CINRStd (dB) Displays the median level of the downlink (DL)


Carrier-to-Interference and Signal-to-Noise (SNR) ratio, measured over
the duration of the link.

43
CHAPTER 5 | WiMAX Settings
Ethernet On-Line Counters

RSSI (dBm) Displays the median level of the downlink Receive


Signal Strength Indicator (RSSI), measured over a duration of two
seconds. The figure will refresh every two seconds.

Last Tx Power (dBm) Displays the most recent transmit data rate
of the CPE in Megabits per second, measured over the last two seconds.
The figure will refresh every two seconds.

UL FEC Code Displays the uplink FEC code.

ETHERNET ON-LINE COUNTERS


The Ethernet On-Line Counters page displays RX and Tx levels for the
Ethernet connection.

Figure 17: Ethernet Counters

ETHERNET ON-LINE COUNTERS The Ethernet On-Line Counters table


describes read-only incremental statistical values of the LAN and WAN
ports.

The following items are displayed on the Ethernet On-Line Counters page:

Rx LAN Port Bit Rate Displays the received bit rate of the Ethernet
LAN port. The figure will refresh every two seconds.

Rx LAN Packet Rate Displays the received packet rate of the


Ethernet LAN port. The figure will refresh every two seconds.

Tx LAN Port Bit Rate Displays the transmitted bit rate of the
Ethernet LAN port. The figure will refresh every two seconds.

44
CHAPTER 5 | WiMAX Settings
Ethernet On-Line Counters

Tx LAN Packet Rate Displays the transmitted packet rate of the


Ethernet LAN port. The figure will refresh every two seconds.

Rx LAN Port Total Bytes Displays the received byte rate of the
Ethernet LAN port. The figure will refresh every two seconds.

Rx LAN Port Total Packets Displays the total received packets of


the Ethernet LAN port. The figure will refresh every two seconds.

Tx LAN Port Total Bytes Displays the transmitted byte rate of the
Ethernet LAN port. The figure will refresh every two seconds.

Tx LAN Port Total Packets Displays the total number of packets


transmitted by the Ethernet LAN port. The figure will refresh every two
seconds.

Rx WAN Port Bit Rate Displays the received bit rate of the WiMAX
WAN port. The figure will refresh every two seconds.

Rx WAN Packet Rate Displays the received packet rate of the


WiMAX WAN port. The figure will refresh every two seconds.

Tx WAN Port Bit Rate Displays the transmitted bit rate of the
WiMAX WAN port. The figure will refresh every two seconds.

Tx WAN Packet Rate Displays the transmitted packet rate of the


WiMAX WAN port. The figure will refresh every two seconds.

Rx WAN Port Total Bytes Displays the total bytes received on the
WiMAX WAN port. The figure will refresh every two seconds.

Rx WAN Port Total Packets Displays the total packets received on


the WiMAX WAN port. The figure will refresh every two seconds.

Tx WAN Port Total Bytes Displays the total bytes transmitted by


the WiMAX WAN port. The figure will refresh every two seconds.

Tx WAN Port Total Packets Displays the total number of packets


transmitted by the WiMAX WAN port. The figure will refresh every two
seconds.

45
CHAPTER 5 | WiMAX Settings
Ethernet On-Line Counters

46
6 SECURITY SETTINGS

The Security menu enables the user to enter station information about for
the CPE, such as user name, password, country of operation and
organisation. It also enables the user to select the authentication method
used to authenticate the CPE with the base station. It contains the
following sections:

User Registration on page 47

USER REGISTRATION The User Registration page allows the user to define registration
parameters such as configured user name, password, organisation and the
country of operation of the CPE. It also allows the user to select the
authentication method.

Figure 18: User Registration

USER REISTRATION The User Registration menu allows the user to


enter information on the authentication parameters required to support
provisioning on the unit.

The following items are displayed on the User Registration page:

User Name Allows the user to enter a user name for the unit, in the
form someone@WiMAX.com.

Password Allows the user to set a password for registration


purposes.

Password Confirm Prompts the user to re-enter the password.

47
CHAPTER 6 | Security Settings

48
7 NAT SETTINGS

This chapter describes NAT settings on the CPE. It includes the following
sections:

Network Address Translation on page 49

Virtual Server on page 49

Demilitarized Zone (DMZ) on page 51

NETWORK ADDRESS TRANSLATION


Network Address Translation (NAT) is a method of mapping between a
single global address on the WAN interface to multiple local addresses on
the LAN interface. For the CPE, the internal (local) IP addresses are those
assigned to PCs or other network devices by the DHCP server, and the
external IP address is the single address assigned to the WAN port.

Figure 19: Network Address Translation

The following items are displayed on the NAT page:

Active Activates NAT.

VIRTUAL SERVER
If you configure the CPE as a virtual server, remote users accessing
services such as web sites or FTP servers on your local network through
public IP addresses can be automatically redirected to local servers
configured with private IP addresses. In other words, depending on the
requested service (designated by the TCP/UDP port number), the CPE
redirects the external service request to the appropriate server (located at
an internal IP address). This secures your network from direct attack by
hackers, and provides more flexible management by allowing you to
change internal IP addresses without affecting outside access to local
network services.

49
CHAPTER 7 | NAT Settings
Virtual Server

For example, if you set Type/Public Port to TCP/80 (HTTP or web) and the
Private IP/Port to 192.168.2.2/80, then all HTTP requests from outside
users will be transferred to 192.168.2.2 on port 80. Therefore, by just
entering the IP address provided by the ISP, Internet users can access the
service they need at the local address to which you redirect them.

The more common TCP service port numbers include: HTTP: 80, FTP: 21,
Telnet: 23, and POP3: 110.

Figure 20: Virtual Server

The following items are displayed on the Virtual Server page:

Active Activates the virtual server.

Rule Name From the drop down menu select the protocol to use.

Private IP Address The IP address of a server on the local network.


The specified address must be in the same subnet as the CPE and its
DHCP server address pool.

Protocol Specifies the port type, TCP or UDP. (Default: TCP)

Private Port Specifies the local LAN TCP/UDP port number. (Range:
1-65535)

Public Port Specifies the WAN port number.

Enable Enables the rule.

50
CHAPTER 7 | NAT Settings
Demilitarized Zone (DMZ)

DEMILITARIZED ZONE (DMZ)


This page is used to allow a specified host on the local network to access
the Internet without any firewall protection. Some Internet applications,
such as interactive games or videoconferencing, may not function properly
behind the CPEs firewall. By specifying a Demilitarized Zone (DMZ) host,
the PC's TCP ports are completely exposed to the Internet, allowing
unrestricted two-way communications. The host PC should be assigned a
static IP address and this address configured as the DMZ host IP.

Figure 21: DMZ

The following items are displayed on the DMZ page:

Active Actives the DMZ service.

IP Address Specify an IP address to allow access to.

51
CHAPTER 7 | NAT Settings
Demilitarized Zone (DMZ)

52
8 FIREWALL SETTINGS

This chapter describes firewall settings on the CPE. It includes the following
section:

Firewall Settings on page 53

Port Filter on page 54

FIREWALL SETTINGS
The CPE provides extensive firewall protection by restricting connection
parameters to limit the risk of intrusion and defending against a wide array
of common hacker attacks.

Figure 22: Firewall Settings

The following items are displayed on the Firewall page:

Mode Enables firewall protection. (Default: Enabled)

Enable Web Server Enables web server protection. (Default:


Enabled)

Enable Telenet Enables Telnet protect. (Default: Enabled)

Enable Ping Enables ping protection. (Default: Enabled)

53
CHAPTER 8 | Firewall Settings
Port Filter

PORT FILTER
You can block access to the Internet from clients on the local network by
specifying TCP/UDP port numbers. You can configure up to five filters on
the unit.

Figure 23: Port Filter

The following items are displayed on the Port Filter page:

Active Enables port filter configuration.

Name Specifies a name to remember the rule by.

Protocol Specifies TCP or UDP.

sport start Specifies the starting port number.

sport_end Specifies the ending port number.

dport_start Specifies the desination port start number.

dport_end Specifies the destination port ending range.

Apply Creates the rule.

54
9 MANAGEMENT SETTINGS

This chapter describes Management settings on the CPE. It includes the


following section:

Resetting the Unit on page 55

Changing the Access Password on page 56

Firmware Upgrade on page 56

Configuration Control on page 57

RESETTING THE UNIT


The Reset page allows you to reset the CPE for configuration changes to
take effect.

NOTE: Reseting the unit does not restore factory defaults.

Figure 24: Reset Unit

The following items are displayed on the Reset Unit page:

Reset Unit Click Reset Unit to reboot the CPE.

55
CHAPTER 9 | Management Settings
Changing the Access Password

CHANGING THE ACCESS PASSWORD


The Change Password page enables you to create a new password for
access to the CPE. It is advisable to change the factory default password
upon receipt of your CPE device.

Figure 25: Change Password

The following items are displayed on the Change Password page:

Old Password Prompts you to enter your current password.

New Password Prompts you to enter a new password. (Length: 1-


20 characters, cannot include the characters <>?:;,.{[}]/\|, and is
case sentivitive.

Confirm New Password Prompts you to re-enter the new


password.

Save New Password Clicking Save New Password saves the new
password and deletes the old password.

FIRMWARE UPGRADE
The Firmware Upgrade page allows you to download new runtime software
for the CPE.

Figure 26: Firmware Upgrade

The following items are displayed on the Firmware Upgrade page:

56
CHAPTER 9 | Management Settings
Configuration Control

Firmware Version Describes the version of the currently loaded


software.

File Name Allows the user to enter the file name of the software file
to be downloaded to the unit.

Apply Click Apply to download user specified software to the unit


from the TFTP IP address.

CONFIGURATION CONTROL
The Configuration Control page allows you to specify an IP address from
which to upload or download a running configuration file. It also allows you
to restore the factory default TFTP server address.

Figure 27: Configuration Control

The following items are displayed on the Configuration Control page:

CONFIGURATION CONTROL Use the configuration control page to


transfer running configuration files.

Backup Configuration File Press Backup to backup the current


running configuration to a local computer.

File Name Allows the user to specify the configuration upload file
name for copying to the TFTP server.

Action Press Apply to restore the factory defaults.TM and PM


Upload Control

57
CHAPTER 9 | Management Settings
SNMP

SNMP
Simple Network Management Protocol (SNMP) is a communication protocol
designed specifically for managing devices on a network. Equipment
commonly managed with SNMP includes switches, routers and host
computers. SNMP is typically used to configure these devices for proper
operation in a network environment, as well as to monitor them to evaluate
performance or detect potential problems.

Managed devices supporting SNMP contain software, which runs locally on


the device and is referred to as an agent. A defined set of variables, known
as managed objects, is maintained by the SNMP agent and used to manage
the device. These objects are defined in a Management Information Base
(MIB) that provides a standard presentation of the information controlled
by the agent. SNMP defines both the format of the MIB specifications and
the protocol used to access this information over the network.

The CPE includes an onboard agent that supports SNMP versions 1, 2c, and
3 clients. This agent continuously monitors the status of the CPE, as well as
the traffic passing to and from wireless clients. A network management
station can access this information using SNMP management software that
is compliant with MIB II. To implement SNMP management, the CPE must
first have an IP address and subnet mask, configured either manually or
dynamically. Access to the onboard agent using SNMP v1 and v2c is
controlled by community strings. To communicate with the CPE, the
management station must first submit a valid community string for
authentication.

Access to the CPE using SNMP v3 provides additional security features that
cover message integrity, authentication, and encryption; as well as
controlling notifications that are sent to specified user targets.

Figure 28: SNMP

The following items are displayed on the

Active Enables the unit to act as an SNMP client.

Read Community Sets the read-only community to public or


private.

Write Community Sets the write community to public or private.

58
10 VOIP SETTINGS (POINTMAX 3000V)

Voice over Internet Protocol (VoIP) technology is a way of using the


Internet to make phone calls. Phone calls can be tranmitted over the
Internet by encoding a voice call into data packets at one end and then
decoding it back into voice calls at the other end. This encoding and
decoding is from a analog signal (your voice) into a digital signal (data
packets) and then back into an analog signal.

The PointMAX 3000V uses Session Initiation Protocol (SIP) as the control
mechanism that sets up, initiates, and terminates calls between a caller
and a called party. The SIP messaging makes use of Proxy, Redirect,
and Registration servers to process call requests and find the location of
called parties across the Internet. When SIP has set up a call between two
parties, the actual voice communication is a direct peer-to-peer connection
using the standard Real-Time Protocol (RTP), which streams the encoded
voice data across the network.

You can make VoIP calls by connecting a regular phone to one of the CPEs
RJ-11 Phone ports. You can also make VoIP calls from your computer using
a VoIP application with a simple microphone and computer speakers. Using
either method, VoIP provides an experience identical to normal
telephoning.

The CPE allows the two RJ-11 Phone ports to be configured separately with
different settings.

This chapter describes the VoIP settings on the CPE. It includes the
following sections:

Enabling VoIP on page 60

SIP Account on page 60

SIP Setting on page 61

Dial Plan on page 61

Call Feature on page 63

Phone Setting on page 63

59
CHAPTER 10 | VoIP Settings (PointMAX 3000V)
Enabling VoIP

ENABLING VOIP
To enable VoIP on the CPE click Apply.

Figure 29: Enabling VoIP

SIP ACCOUNT
From the VoIP SIP Account page, you can set up SIP account numbers,
usernames and passwords.

Figure 30: SIP Account Settings

Telephone Number The SIP account user number provided by the


service operator.

Outgoing Display name The name associated with the telephone


number entered.

SIP user name Enter your SIP user name.

SIP user password Enter your SIP password.

Confirm SIP user password Re-enter your SIP password.

60
CHAPTER 10 | VoIP Settings (PointMAX 3000V)
SIP Setting

SIP server IP/Domain name Enter the IP address or server


domain name of the SIP server.

SIP Server Port Enter the port associated with SIP server traffic.
(Default: 5060)

Keep Alive I/O Period The length of time, in seconds, to keep the
SIP connection open. (Default: 57600 seconds)

SIP SETTING
The SIP Setting page allows you to configure RTP and DTMF settings.

Figure 31: SIP Settings

RTP Port The Real-time Transport Protocol (RTP) defines a


standardized packet format for delivering audio and video over the
Internet.

DTMF Key Pad Defines the Dual-tone multi-frequency (DTMF)


signaling used for telecommunication signaling over analog telephone
lines in the voice-frequency band between telephone handsets and
other communications devices and the switching center.

DIAL PLAN
Dial-plan strings specify key sequences used for specific calling features
(Transfer, New Call, 3-way conference), as well as defining call restriction
filters.

A dial plan can filter the number and pattern of digits that a user dials to
reach a particular telephone number. Access codes, area codes, specialized
codes, and combinations of the number of digits dialed can all be part of a
dial plan. This enables a user to predefine dialling sequences that are
permitted.

The dial-plan string consists of a single digit rule. A typical example of a


dial-plan string is: [0123]xxxxxx.t

Three standard dial plans are defined; Call Transfer Key, New Call Key, and
3-way Conference. Up to 10 other dial plans can be defined by the user.

61
CHAPTER 10 | VoIP Settings (PointMAX 3000V)
Dial Plan

Figure 32: Dial Plan Settings

The function of elements allowed in a dial plan are described in the table
below:

Table 3: Dial Plan Elements

Element Example Description

x xxxx Represents a digit of any value ( 0 to 9) that can be dialed on a


phone. This example has a rule with four digits of any number.

. xx. Indicates zero or more occurrences of the previous symbol. The


example acts like a wildcard, meaning any dialed phone number
of two or more digits is allowed.

0-9 01xx Indicates dialed digits that must be matched. This example only
allows four-digit numbers starting 01.

[ ] [125-8] Limits a dialed digit to specified values or a range of values. The


example specifies that only digits 1, 2, 5, 6, 7, and 8 are
permitted.

t xx.t The timeout indicator that can placed after dialed digits or at the
end of the dial-plan string.

When a user dials a series of digits, the dial-plan rule is tested for a
possible match. If a match is made, the dialed sequence is transmitted. If
no match is made, the dialed number is blocked and the user will hear an
error tone.

A dial-plan string cannot include spaces between elements. Dialed


sequences that are longer than specified in a dial-plan rule are truncated
after the number of specified digits. For example, if the dial-plan rule is
011x and 0115678 is dialed, only the digit sequence 0115 is
transmitted.

62
CHAPTER 10 | VoIP Settings (PointMAX 3000V)
Call Feature

CALL FEATURE
The PointMAX 3000 allows you to configure several call features, such as
call waiting and call-transfer. Other call features can be implemented by
pressing specific phone buttons or entering dial patterns.

The table below describes the various call features available.

NOTE: Some call features may be dependent on support at the SIP server.
Check with the SIP service provider.

Table 4: VoIP Call Features

Call Feature Description Activation

Call Hold Places an active call on Press the Flash, Flash Hook, or Hold
hold for an unlimited button on the phone.
period of time.

Call Waiting If during a call there is This feature must first be enabled using
another incoming call, an the web interface. You can place the
alert tone is heard. active call on hold and switch to the
incoming call. You can switch between
the two calls by placing the active call on
hold.

Call Transfer Transfers any received First place the received call on hold, then
call to another number dial the transfer key sequence *#.
you specify. When you hear a dial tone, enter the
transfer phone number, then hang up.

3-Way Conference Calls two numbers, then Dial the first number, then place it on
allows all to talk together. hold. Dial the key sequence ** and
wait until you hear the dial tone, then
dial the second number. When the
second call is active, dial *3 to
establish the three-way conference.

Figure 33: Call Features

Call Waiting Enables a call waiting alert. If during a call there is


another incoming call, an alert tone is heard. You can place the active
call on hold (press the Flash, Flash Hook, or Hold button on the
phone) and switch to the incoming call. (Default: Disabled)

PHONE SETTING
The Phone Setting page allows you to select voice quality parameters.

63
CHAPTER 10 | VoIP Settings (PointMAX 3000V)
Phone Setting

Figure 34: Phone Settings

Incoming CLI Enables/disables incoming CLI messages.

Silence Suppression Enables/disables silence suppression during


periods of non-talkative activity.

Echo Cancelar Enables/disables echo cancellation on voice calls.

Do Not Disturb Enable Check this box to enable a block on calls to


your SIP number.

Telephone Volume Select between 1 and 10 for the most suitable


volume for your SIP connection.

64
11 STATUS

This chapter describes Status settings on the PointMAX 3000. It includes


the following sections:

System Status on page 66

Radio on page 68

Registration Parameters on page 68

System Log on page 69

65
CHAPTER 11 | Status
System Status

SYSTEM STATUS
The Status page is a display-only menu of non-configurable parameters for
Unit Control, Registration, Base Station Identification (BSID), Radio, Multi
rate, Adaptative Transmission Power Control (ATPC) and Service. To
configure the parameters associated with each show menu item refer to
the sections listed in the main menu.

Figure 35: Show All

The following items are displayed on the Show All page:

CPE Family Describes the primary chipset of the CPE.

Serial Number Describes the serial number of the CPE unit. This
number can be used to determine the identity of the subscriber unit by
the base station operator.

LAN MAC Address Describes the physical layer address of the LAN
port.

WAN MAC Address The WAN port MAC address can be determined
by adding 1 to the LAN port MAC address.

66
CHAPTER 11 | Status
System Status

LAN IP Address The IP address of the LAN port.

LAN Subnet Mask Describes the subnet mask used by the LAN
port.

WAN IP Address The IP address of the wireless WAN port.

WAN Subnet Mask The subnet mask of the wireless WAN port.

WAN Gateway The gateway address of the wireless WAN port.

Radio Band Describes the radio band in use. The radio bands for the
CPE are 2.3, 2.5, 3.5 and 5 GHz.

Hardware version Describes the revision of hardware in use.

Hardware configuration Describes the identity of the current


hardware configuration by serial number.

RF version Describes the radio frequency (RF) or rate of oscillation


of the electrical circuit.

Interface Type Describes the number of ports available on the


interface. D refers to data ports, V refers to VoIP ports, with a prefix
number in use as a quantifier.

Radio Type Describes the receive (Rx) and transmit (Tx) capacity of
the radio.

Operation Mode Describes the operation mode of the Extreme CPE,


either IPCS or ETHCS, where IPCS refers to transparent delivery of IPv4
packets and ETHCS refers to transparent delivery of tagged 802.3
packets over Ethernet.

Unit Status Describes the connectivity status of the Extreme CPE to


the base station.

WiMAX Operation Period The length of time in seconds that the


unit has received a WiMAX signam from a base station.

WiMAX Reconnection Times The number of times that the unit


has lost a connection to a base station and reconnected.

Firmware Version Describes the version of the current firmware.

Firmware Release Date The release date of the current firware


loaded on the CPE.

System Uptime The length of time in seconds, minutes and hours


that the unit has been booted up.

67
CHAPTER 11 | Status
Radio

RADIO
Describes the availability of VoIP ports, operator preset maximum
information rates (MIR), Ethernet status, virtual private networks (VPN)
status and switching antenna status.

Figure 36: Radio Settings

The following items are displayed on the License Type page:

Configured Bandwidth Describes the configured radio bandwidth


in Megaherthz.

Current Bandwidth Describes the current bandwidth of the WiMAx


link.

REGISTRATION PARAMETERS
Registration parameters displays information on the authentication
parameters required to support provisioning on the unit.

Figure 37: Registration

The following items are displayed on the Show All parameters, Registration
Parameters page:

Configure User Name Describes the configured user name for the
unit.

Actual User Name Describes the current name being used to


identify the user of the unit.

Outer Identity Describes the contact information for the WiMAX


subscriber.

68
CHAPTER 11 | Status
System Log

Authentication Describes the method of authentication being used


to secure the WiMAX connection.

SYSTEM LOG
The System Log page displays logging messages about system activity.

Figure 38: Registration

69
CHAPTER 11 | Status
System Log

70
12 LOGOUT

This chapter describes how to log out of the CPE. It includes the following
section:

Logging Out on page 71

LOGGING OUT
The Logout page enables you to log out of the web interface and terminate
your session. Logging out is proceeded by a prompt to log in again.

Figure 39: Logout

The following items are displayed on the Logout page:

Logout Logs you out of the current session.

Figure 40: Login

Login Logs you into the system. The default password is installer.

71
CHAPTER 12 | Logout
Logging Out

72
SECTION III
APPENDICES

This section provides additional information and includes these items:

Troubleshooting on page 75

Hardware Specifications on page 77

Cables and Pinouts on page 83

Glossary on page 87

Index on page 91

73
SECTION | Appendices

74
A TROUBLESHOOTING

DIAGNOSING LED INDICATORS


Table 5: LED Indicators

Symptom Action

Power LED is off The AC power adapter may be disconnected. Check


connections between the unit, the power adapter, and the
wall outlet.

Power LED is red Indicates that the CPE has experienced a critical error.

Power LED is flashing Authentication between the CPE and the WiMAX network has
amber failed.

LAN LED is off Verify that the unit and attached device are powered on.
(when port connected)
Be sure the cable is plugged into both the unit and
corresponding device.
Verify that the proper cable type is used and its length does
not exceed specified limits.
Check the cable connections for possible defects. Replace the
defective cable if necessary.

WiMAX Signal Strength There is no detected signal from a WiMAX base station.
LEDs are off Check the radio settings in the management interface.

BEFORE CONTACTING TECHNICAL SUPPORT


Check the following items before you contact local Technical Support.

1. If wireless clients cannot access the network, check the following:

If authentication or encryption are enabled, ensure that the wireless


clients are properly configured with the appropriate authentication
or encryption keys.

2. If the CPE cannot be configured using a web browser:

Be sure to have configured the CPE with a valid IP address, subnet


mask and default gateway.

Check that you have a valid network connection to the CPE and that
the Ethernet port or the wireless interface that you are using has
not been disabled.

75
APPENDIX A | Troubleshooting
Before Contacting Technical Support

If you are connecting to the CPE through the wired Ethernet


interface, check the network cabling between the management
station and the CPE. If you are connecting to CPE from a wireless
client, ensure that you have a valid connection to the CPE.

3. If you forgot or lost the password, contact technical support for


assistance.

4. If all other recovery measure fail, and the CPE is still not functioning
properly, take any of these steps:

Reset the CPEs hardware using the reset button, through the web
interface, or through a power reset. Then use the default password
installer to access the management interface.

76
B HARDWARE SPECIFICATIONS

WIMAX RADIO SPECIFICATIONS

RADIO TYPE IEEE 802.16e WAVE 1 & WAVE 2

FREQUENCY BAND 2496~2690 MHz (FCC), 2500~2690 MHz (CE)


RANGE

ANTENNA TYPE External Omni-dipole antennas with MRC function

CHANNEL BANDWIDTH 5.00 and 10.00 MHz

MAXIMUM THROUGHPUT 5 Mbps Upload, 20 Mbps download

MODULATION TECHNIQUE Scaleable OFDMA employing Time-Division Duplex (TDD) mechanism

PRBS subcarrier randomization

Contains pilot, preamble, and ranging modulation

FEC CODING RATES Down Link: QPSK, 16 QAM, 64 QAM

Up Link: QPSK, 16 QAM

ANTENNA GAIN 2.5 GHz 5 dBi

TPL (TRANSMIT POWER +24~26 dBm maximum (+/- 2dBm)


LEVEL)

RECEIVE SENSITIVITY -94 dBm maximum

77
APPENDIX B | Hardware Specifications
VoIP Specifcations

VOIP SPECIFCATIONS

VOICE SIGNALLING SIP v2 (RFC 3261)


PROTOCOL

VOICE CODECS G.711 (a-law and u-law)

G.729ab

G.722

G.722.1

VOICE QUALITY G.726 VAD (Voice Activity Detection)

G.723 CNG (Comfortable Noise Generation)

Echo cancellation (G.165/G.168)

Adaptive jitter buffer, up to 200 milliseconds

DTMF tone detection and generation

Configurable Cadence Rings

CALL FEATURES Call transfer

Call waiting/hold/retrieve

3-way conference call

Call blocking

T.38 fax relay

Dial plan (E.164 dialing plan)

Call forwarding: No Answer/Busy/All

REN (RING EQUIVILENT 3 REN total in system


NUMBER)

78
APPENDIX B | Hardware Specifications
Configuration and Management

CONFIGURATION AND MANAGEMENT

MANAGEMENT OPTIONS Web-based (HTTP)

MANAGEMENT ACCESS From Wired LAN, Wireless Link

MANAGEMENT ACCESS Access Password


PROTECTION

ENCRYPTION PKMv2 with 128bit AES/CCM

ALLOCATION OF IP Configurable or automatic (DHCP client)


PARAMETERS

SOFTWARE UPGRADE HTTP

CONFIGURATION HTTP
UPLOAD/DOWNLOAD

MECHANICAL

DIMENSIONS 18.6 cm X 12.5 cm X 3.4 cm (7.32 x 4.92 x 1.34 inches)

WEIGHT 262.4g (0.578lb)

MOUNTING Desktop or wall

CABLING Category 5 cable connection

79
APPENDIX B | Hardware Specifications
Electrical

ELECTRICAL

AC POWER SUPPLY Input: 100-240 VAC, 50-60 Hz, maximum power consumption 1.0A

Output: 12 VDC @ 1.5A, maximum power consumption 18A

MTBF 5 years

ENVIRONMENTAL

OPERATING -5C to 45C


TEMPERATURE

STORAGE TEMPERATURE -40 to 75 C

HUMIDITY Maximum 95%, non-condensing

STANDARDS COMPLIANCE

EMC FCC Part 15B Class B

EN 55022

EN 55022 + EN 55024 Class B

EN 301 489-1/4

SAFETY EN 60950-1 (2006)

WIMAX RADIO SIGNAL EN 302 326


CERTIFICATION
FCC Part 27M

80
APPENDIX B | Hardware Specifications
Standards Compliance

STANDARDS IEEE 802.16e-2005 WAVE 1 and WAVE 2

IEEE 802.3-2005 10BASE-T and 100BASE-TX

81
APPENDIX B | Hardware Specifications
Standards Compliance

82
C CABLES AND PINOUTS

TWISTED-PAIR CABLE ASSIGNMENTS


For 10/100BASE-TX connections, a twisted-pair cable must have two pairs
of wires. Each wire pair is identified by two different colors. For example,
one wire might be green and the other, green with white stripes. Also, an
RJ-45 connector must be attached to both ends of the cable.

NOTE: Each wire pair must be attached to the RJ-45 connectors in a specific
orientation.

CAUTION: DO NOT plug a phone jack connector into the RJ-45 port. Use
only twisted-pair cables with RJ-45 connectors that conform with FCC
standards.

The following figure illustrates how the pins on the RJ-45 connector are
numbered. Be sure to hold the connectors in the same orientation when
attaching the wires to the pins.

Figure 41: RJ-45 Connector

8
8
1 1

10/100BASE-TX PIN Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for
ASSIGNMENTS RJ-45 connections: 100-ohm Category 3 or better cable for 10 Mbps
connections. Also be sure that the length of any twisted-pair connection
does not exceed 100 meters (328 feet).

The RJ-45 port on the CPE supports automatic MDI/MDI-X operation, so


you can use straight-through or crossover cables for all network
connections to PCs, switches, or hubs. In straight-through cable, pins 1, 2,
3, and 6, at one end of the cable, are connected straight through to pins 1,
2, 3, and 6 at the other end of the cable.

83
APPENDIX C | Cables and Pinouts
Twisted-Pair Cable Assignments

Table 6: 10/100BASE-TX MDI and MDI-X Port Pinouts

PIN MDI Signal Namea MDI-X Signal Name

1 Transmit Data plus (TD+) Receive Data plus (RD+)

2 Transmit Data minus (TD-) Receive Data minus (RD-)

3 Receive Data plus (RD+) Transmit Data plus (TD+)

6 Receive Data minus (RD-) Transmit Data minus (TD-)

4,5,7,8 Not used

a. The + and - signs represent the polarity of the wires that make up each wire
pair.

STRAIGHT-THROUGH If the twisted-pair cable is to join two ports and only one of the ports has
WIRING an internal crossover (MDI-X), the two pairs of wires must be straight-
through. (When auto-negotiation is enabled for any RJ-45 port on this CPE,
you can use either straight-through or crossover cable to connect to any
device type.)

You must connect all four wire pairs as shown in the following diagram to
support Gigabit Ethernet connections.

Figure 42: Straight Through Wiring

EIA/TIA 568B RJ-45 Wiring Standard


10/100BASE-TX Straight-through Cable

White/Orange Stripe

Orange

1 White/Green Stripe 1
End A 2 2 End B
3 Blue 3
4 4
5 White/Blue Stripe 5
6 6
7 Green 7
8 White/Brown Stripe 8

Brown

CROSSOVER WIRING If the twisted-pair cable is to join two ports and either both ports are
labeled with an X (MDI-X) or neither port is labeled with an X (MDI), a
crossover must be implemented in the wiring. (When auto-negotiation is
enabled for any RJ-45 port on this CPE, you can use either straight-through
or crossover cable to connect to any device type.)

You must connect all four wire pairs as shown in the following diagram to
support Gigabit Ethernet connections.

84
APPENDIX C | Cables and Pinouts
Twisted-Pair Cable Assignments

Figure 43: Crossover Wiring


EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Crossover Cable

White/Orange Stripe

Orange

1 White/Green Stripe 1
End A 2 2 End B
3 Blue 3
4 4
5 White/Blue Stripe 5
6 6
7 Green 7
8 White/Brown Stripe 8

Brown

85
APPENDIX C | Cables and Pinouts
Twisted-Pair Cable Assignments

86
GLOSSARY

10BASE-T IEEE 802.3-2005 specification for 10 Mbps Ethernet over two pairs of
Category 3 or better UTP cable.

100BASE-TX IEEE 802.3-2005 specification for 100 Mbps Fast Ethernet over two pairs of
Category 5 or better UTP cable.

ADVANCED ENCRYPTION An encryption algorithm that implements symmetric key cryptography. AES
STANDARD (AES) provides very strong encryption using a completely different ciphering
algorithm to TKIP and WEP.

AUTHENTICATION The process to verify the identity of a client requesting network access.
IEEE 802.11 specifies two forms of authentication: open system and
shared key.

BACKBONE The core infrastructure of a network. The portion of the network that
transports information from one central location to another central location
where it is unloaded onto a local system.

BEACON A signal periodically transmitted from the CPE that is used to identify the
service set, and to maintain contact with wireless clients.

BROADCAST KEY Broadcast keys are sent to stations using dynamic keying. Dynamic
broadcast key rotation is often used to allow the CPE to generate a random
group key and periodically update all key-management capable wireless
clients.

DYNAMIC HOST Provides a framework for passing configuration information to hosts on a


CONFIGURATION TCP/IP network. DHCP is based on the Bootstrap Protocol (BOOTP), adding
PROTOCOL (DHCP) the capability of automatic allocation of reusable network addresses and
additional configuration options.

ENCRYPTION Data passing between the CPE and clients can use encryption to protect
from interception and evesdropping.

87
GLOSSARY

ETHERNET A popular local area data communications network, which accepts


transmission from computers and terminals.

FILE TRANSFER A TCP/IP protocol used for file transfer.


PROTOCOL (FTP)

HYPERTEXT TRANSFER HTTP is a standard used to transmit and receive all data over the World
PROTOCOL (HTTP) Wide Web.

INFRASTRUCTURE An integrated wireless and wired LAN is called an infrastructure


configuration.

LOCAL AREA NETWORK A group of interconnected computer and support devices.


(LAN)

MAC ADDRESS The physical layer address used to uniquely identify network nodes.

NETWORK TIME NTP provides the mechanisms to synchronize time across the network. The
PROTOCOL (NTP) time servers operate in a hierarchical-master-slave configuration in order
to synchronize local clocks within the subnet and to national time
standards via wire or radio.

OPEN SYSTEM A security option which broadcasts a beacon signal including the CPEs
configured SSID. Wireless clients can read the SSID from the beacon, and
automatically reset their SSID to allow immediate connection to the
nearest CPE.

ORTHOGONAL OFDM allows multiple users to transmit in an allocated band by dividing the
FREQUENCY DIVISION bandwidth into many narrow bandwidth carriers.
MULTIPLEXING (ODFM)

SERVICE SET IDENTIFIER An identifier that is attached to packets sent over the wireless LAN and
(SSID) functions as a password for joining a particular radio cell; i.e., Basic Service
Set (BSS).

SESSION KEY Session keys are unique to each client, and are used to authenticate a
client connection, and correlate traffic passing between a specific client and
the CPE.

88
GLOSSARY

SHARED KEY A shared key can be used to authenticate each client attached to a wireless
network. Shared Key authentication must be used along with the 802.11
Wireless Equivalent Privacy algorithm.

SIMPLE NETWORK TIME SNTP allows a device to set its internal clock based on periodic updates
PROTOCOL (SNTP) from a Network Time Protocol (NTP) server. Updates can be requested from
a specific NTP server, or can be received via broadcasts sent by NTP
servers.

TEMPORAL KEY A data encryption method designed as a replacement for WEP. TKIP avoids
INTEGRITY PROTOCOL the problems of WEP static keys by dynamically changing data encryption
(TKIP) keys.

TRIVIAL FILE TRANSFER A TCP/IP protocol commonly used for software downloads.
PROTOCOL (TFTP)

VIRTUAL CPE (VAP) Virtual AP technology multiplies the number of CPEs present within the RF
footprint of a single physical access device. With Virtual AP technology,
WLAN users within the device.s footprint can associate with what appears
to be different CPEs and their associated network services. All the services
are delivered using a single radio channel, enabling Virtual AP technology
to optimize the use of limited WLAN radio spectrum.

WI-FI PROTECTED WPA employs 802.1X as its basic framework for user authentication and
ACCESS dynamic key management to provide an enhanced security solution for
802.11 wireless networks.

WIRED EQUIVALENT WEP is based on the use of security keys and the popular RC4 encryption
PRIVACY (WEP) algorithm. Wireless devices without a valid WEP key will be excluded from
network traffic.

WPA PRE-SHARED KEY WPA-PSK can be used for small office networks with a limited number of
(WPA-PSK) users that may not need a high level of security. WPA-PSK provides a
simple security implementation that uses just a pre-shared password for
network access.

89
GLOSSARY

90
INDEX

A N
antennas 21 NAT settings 49

C P
configuration control 57 package contents 18
password 56
power connector 23
D
diagnosing LED indicators 75
DMZ 51 R
reset button 23
resetting the unit 55
E
Ethernet on-line counters 44
Ethernet port 23 S
security settings 47
user registration 47
F SNTP 38
firewall settings 53 software version control 56
frequency scanning 42 system status 66
scanning table 42 show registration 68

H V
hardware description 19 virtual server 49

I W
initial configuration 31 WAN settings 35
installing the access point 25
introduction 17

K
key features 17

L
LAN settings 37
LED indicators 22
link quality counters 43
location selection 25
logging out 71

M
mounting on a horizontal surface 26
mounting on a wall 27

91
INDEX

92
PointMAX 3000
PointMAX 3000V
E122009-CS-R01
149100000076W

You might also like