Professional Documents
Culture Documents
LINEA DE CONDUCCION 1
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CAPTACION 01 4,288.00
J-1 4,281.08 0.100 0.55 69.2 0.97 1.00
J-2 4,269.81 0.100 0.55 121.0 0.87 1.00
J-3 4,257.73 0.100 0.55 180.8 0.80 1.00
CAMARA REUNION 01 4,247.10 0.106 0.55 213.3 0.77 1.00
CAPTACION 02 4,254.00
CAMARA REUNION 01 4,247.10 0.055 0.19 125.8 0.58 0.75
CAPTACION 03 4,288.00
CAMARA REUNION 01 4,247.10 0.135 0.16 302.6 0.45 0.75
CAMARA REUNION 01 4,247.10
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 1
NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
NUDO
DINAMICO (KM) TRAMO (S) (") COMERC.
RESERVORIO 1 4,155.05
J-26 4,152.50 0.007 0.12 386.4 0.39 0.75
J-28 4,143.86 0.179 0.02 62.1 0.29 0.75
J-29 4,143.98 0.046 0.02 234.7 0.22 0.75
J-26 4,152.50
J-27 4,136.34 0.061 0.03 304.2 0.25 0.75
J-31 4,119.00 0.097 0.02 368.4 0.20 0.75
J-32 4,118.95 0.071 0.02 506.3 0.19 0.75
J-33 4,123.00 0.085 0.02 374.5 0.20 0.75
J-34 4,113.25 0.191 0.01 216.9 0.18 0.75
J-26 4,152.50
J-30 4,123.91 0.196 0.07 158.1 0.37 0.75
CRP T7 - 01 4,104.00 0.173 0.07 289.1 0.33 0.75
CRP T7 - 01 4,104.00
J-36 4,097.74 0.064 0.07 97.9 0.41 0.75
J-37 4,081.47 0.085 0.03 260.6 0.26 0.75
J-38 4,071.95 0.097 0.03 325.3 0.24 0.75
J-39 4,058.07 0.162 0.02 279.3 0.22 0.75
CRP T7 - 02 4,054.00 0.173 0.02 285.4 0.22 0.75
CRP T7 - 02 4,054.00
J-40 4,025.71 0.150 0.02 189.0 0.23 0.75
1.837
DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
Estimado
33.18
99.55
VEL.
Hf H PIEZOM. PRESION C. P.SALIDA
FLUJO
4,155.05
0.43 0.10 4,154.95 2.45 4,154.95
0.08 0.12 4,154.83 10.97 4,154.83
0.08 0.03 4,154.80 10.82 4,154.80
4,154.95
0.12 0.09 4,154.86 18.52 4,154.86
0.08 0.06 4,154.80 35.80 4,154.80
0.08 0.05 4,154.75 35.80 4,154.75
0.08 0.06 4,154.70 31.70 4,154.70
0.04 0.03 4,154.66 41.41 4,154.66
4,154.95
0.24 0.99 4,153.96 30.05 4,153.96
0.24 0.87 4,153.09 49.09 4,153.09
4,104.00
0.24 0.32 4,103.68 5.94 4,103.68
0.12 0.12 4,103.56 22.09 4,103.56
0.12 0.14 4,103.42 31.47 4,103.42
0.08 0.11 4,103.32 45.25 4,103.32
0.08 0.11 4,103.20 49.20 4,103.20
4,054.00
0.08 0.10 4,053.90 28.19 4,053.90
HOJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
J-29 (CD-01) 4,203.00
J-31 4,186.43 0.153 0.45 108.6 0.82 1.00 0.89
J-33 4,179.37 0.100 0.45 172.1 0.75 1.00 0.89
J-35 4,173.88 0.100 0.45 185.0 0.74 1.00 0.89
J-38 4,163.85 0.100 0.45 243.3 0.70 1.00 0.89
J-40 4,154.22 0.100 0.45 297.5 0.67 1.00 0.89
J-52 (CD-03) 4,151.00 0.056 0.45 518.2 0.60 1.00 0.89
J-52 (CD-03) 4,151.00
J-54 4,141.31 0.265 0.02 36.5 0.33 0.75 0.08
J-55 4,137.70 0.115 0.02 113.9 0.26 0.75 0.08
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 2
NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
NUDO DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
RESERVORIO 2 4,130.00
Fuente: INEI
ZONA SIERRA
1.30
2.00
Estimado
33.18
99.55
4,203.00
6.42 4,196.58 10.15 4,196.58
4.20 4,192.38 13.01 4,192.38
4.20 4,188.18 14.30 4,188.18
4.20 4,183.97 20.12 4,183.97
4.20 4,179.77 25.55 4,179.77
2.33 4,177.43 26.43 4,177.43
4,151.00
0.17 4,150.83 9.52 4,150.83
0.07 4,150.76 13.06 4,150.76
DE CALCULO N 01
4,130.00
0.20 4,129.80 20.30 4,129.80
HOJA DE CALCULO N 01
CALCULOS PARA REDES DE AGUA POTA
"MEJORAMIENTO Y AMPLIACION DEL SISTEM
-NOMBRE DEL PROYECTO: COMUNIDADES DE CHITIBAMBA, CONSAPATA, C
-UBICACIN:
SISTEMA CCOCHAPAMPA
A UTILIZAR :
Qunitario = Qmh/#viviendas
LINEA DE CONDUCCION
NUDO
CAPTACION NIVEL LONG. Q DEL PENDIENTE DIAMETRO
CALLHUACHACANA DINAMICO (KM) TRAMO (S) (")
01 3,882.42
CAPTACION
CR
CALLHUACHACANA 3,877.74 0.015 0.05 308.3 0.28
02
CAMARA DE 3,882.65
REUNION 1
CAMARA DE 3,877.74 0.012 0.05 406.1 0.26
REUNION 1 3,877.74
RESERVORIO 3,874.52 0.047 0.05 68.2 0.38
RED DE DISTRIBUCION 3
NIVEL LONG. Q DEL PENDIENTE DIAMETRO
NUDO
DINAMICO (KM) TRAMO (S) (")
RESERVORIO 3,874.52
A 3,869.89 0.023 0.21 202.2 0.54
B 3,855.98 0.176 0.13 99.8 0.52
J - 14 4,162.39 0.073 0.12 (3,988.1) #VALUE!
J - 18 4,151.45 0.123 0.10 (2,289.2) #VALUE!
J - 22 4,130.25 0.156 0.10 (1,677.9) #VALUE!
CRP T7 - 03 4,121.00 0.224 0.09 (1,137.0) #VALUE!
CRP T7 - 03 4,121.00
J - 24 4,110.50 0.248 0.09 42.3 0.55
J - 41 4,095.38 0.331 0.05 70.5 0.38
J - 42 4,093.65 0.204 0.05 118.9 0.34
J - 14 4,162.39
J - 15 4,138.43 0.204 0.01 (1,318.9) #VALUE!
J - 24 4,110.50
J - 26 4,113.50 0.130 0.01 40.2 0.25
A 3,869.89
J - 10 4,164.04 0.224 0.08 (1,297.8) #VALUE!
J - 13 4,159.67 0.190 0.07 (1,516.6) #VALUE!
J - 16 4,161.59 0.177 0.07 (1,640.4) #VALUE!
J - 17 4,160.78 0.160 0.06 (1,822.0) #VALUE!
J - 19 4,155.82 0.058 0.05 (4,976.3) #VALUE!
J - 20 4,126.08 0.300 0.03 (855.3) #VALUE!
CRP T7 - 04 4,123.19 0.202 0.03 (1,258.2) #VALUE!
CRP T7 - 04 4,123.19
J - 35 4,113.13 0.180 0.03 56.0 0.36
J - 10 4,164.04
J - 11 4,159.00 0.047 0.01 (6,154.1) #VALUE!
A DE CALCULO N 01
ARA REDES DE AGUA POTABLE
AMPLIACION DEL SISTEMA DE SANEAMIENTO BASICO INTEGRAL EN LAS
ITIBAMBA, CONSAPATA, CHULLUNQUIANI Y KUTY ANANSAYA, EN EL DIST. DE
CHECCA, PROV. CANAS - CUSCO".
30
90 ZONA SIERRA
0.03
K1= 1.30
K2= 2.00
0.05
0.10 Estimado
0.75 33.18
0.08 99.55
0.83
1.00 Reservorio, proyectado, Cubico
0.07
0.012
3,874.52
0.75 0.73 0.94 3,873.58 3.69 3,873.58
0.75 0.45 2.91 3,870.66 14.68 3,870.66
0.75 0.41 1.01 3,869.65 (292.74) 3,869.65
0.75 0.37 1.40 3,868.24 (283.21) 3,868.24
0.75 0.37 1.78 3,866.46 (263.79) 3,866.46
0.75 0.33 2.05 3,864.41 (256.59) 3,864.41
4,121.00
0.75 0.33 2.27 4,118.73 8.23 4,118.73
0.75 0.16 0.84 4,117.88 22.50 4,117.88
0.75 0.16 0.52 4,117.36 23.71 4,117.36
3,869.65
0.75 0.04 0.04 3,869.61 (268.82) 3,869.61
4,118.73
0.75 0.04 0.03 4,118.70 5.20 4,118.70
3,873.58
0.75 0.28 1.60 3,871.97 (292.07) 3,871.97
0.75 0.24 1.02 3,870.95 (288.72) 3,870.95
0.75 0.24 0.95 3,870.00 (291.59) 3,870.00
0.75 0.20 0.61 3,869.38 (291.40) 3,869.38
0.75 0.16 0.15 3,869.24 (286.58) 3,869.24
0.75 0.12 0.45 3,868.79 (257.29) 3,868.79
0.75 0.12 0.30 3,868.48 (254.71) 3,868.48
4,123.19
0.75 0.12 0.27 4,122.92 9.79 4,122.92
3,871.97
0.75 0.04 0.01 3,871.96 (287.04) 3,871.96
HOJA DE CALCULO N 01
CALCULOS PARA REDES DE AGUA P
"MEJORAMIENTO Y AMPLIACION DEL
-NOMBRE DEL PROYECTO: COMUNIDADES DE CHITIBAMBA, CONSA
-UBICACIN:
SISTEMA CCOCHAPAMPA
A UTILIZAR :
Qunitario = Qmh/#viviendas
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO
DINAMICO (KM) TRAMO (S) (")
CAPTACION SURANI 01 4,237.00
CR 4,232.00 0.050 0.05 100.4 0.35
CAPTACION SURANI 02 4,234.00
CAMARA DE REUNION 1 4,232.00 0.024 0.05 82.7 0.36
CAMARA DE REUNION 1 4,234.00
J - 19 4,228.44 0.047 0.05 117.7 0.34
J - 22 4,217.63 0.100 0.05 162.6 0.32
J - 25 4,195.77 0.100 0.05 378.7 0.27
J - 26 4,190.78 0.100 0.05 426.2 0.26
J - 27 4,192.45 0.100 0.05 407.1 0.26
J - 28 4,192.94 0.100 0.05 399.7 0.26
J - 36 4,198.70 0.096 0.05 353.9 0.27
J - 43 4,193.55 0.131 0.05 297.2 0.28
J - 47 4,188.12 0.100 0.05 440.4 0.26
J - 50 4,180.68 0.100 0.05 512.0 0.25
RESERVORIO 4,179.14 0.047 0.05 1,118.8 0.21
RED DE DISTRIBUCION 3
NIVEL LONG. Q DEL PENDIENTE DIAMETRO
NUDO
DINAMICO (KM) TRAMO (S) (")
RESERVORIO 4,179.14
J - 09 4,177.30 0.015 0.07 119.6 0.40
J - 12 4,166.81 0.116 0.04 106.0 0.34
J - 14 4,162.39 0.073 0.04 224.4 0.28
J - 18 4,151.45 0.123 0.03 221.2 0.27
J - 22 4,130.25 0.156 0.03 308.9 0.25
CRP T7 - 03 4,121.00 0.224 0.03 255.8 0.25
CRP T7 - 03 4,121.00
J - 24 4,110.50 0.248 0.03 42.3 0.36
J - 41 4,095.38 0.331 0.02 76.5 0.25
J - 42 4,093.65 0.204 0.02 132.2 0.22
J - 14 4,162.39
J - 15 4,138.43 0.204 0.00 197.5 0.12
J - 24 4,110.50
J - 26 4,113.50 0.130 0.00 55.5 0.15
J - 09 4,177.30
J - 10 4,164.04 0.224 0.03 67.1 0.31
J - 13 4,159.67 0.190 0.02 101.1 0.27
J - 16 4,161.59 0.177 0.02 96.6 0.27
J - 17 4,160.78 0.160 0.02 111.6 0.25
J - 19 4,155.82 0.058 0.02 394.2 0.18
J - 20 4,126.08 0.300 0.01 174.5 0.19
CRP T7 - 04 4,123.19 0.202 0.01 273.2 0.17
CRP T7 - 04 4,123.19
J - 35 4,113.13 0.180 0.01 56.0 0.23
J - 10 4,164.04
J - 11 4,159.00 0.047 0.00 425.5 0.10
E CALCULO N 01
REDES DE AGUA POTABLE
Y AMPLIACION DEL SISTEMA DE SANEAMIENTO BASICO INTEGRAL EN LAS
ITIBAMBA, CONSAPATA, CHULLUNQUIANI Y KUTY ANANSAYA, EN EL DIST. DE
CHECCA, PROV. CANAS - CUSCO".
30
90 ZONA SIERRA
0.03
K1= 1.30
K2= 2.00
0.05
0.10 Estimado
0.75 33.18
0.08 99.55
0.83
1.00 Reservorio, proyectado, Cubico
0.07
0.012
DIAM. VEL.
Hf H PIEZOM. PRESION C. P.SALIDA
COMERC. FLUJO
4,179.14
0.75 0.24 0.08 4,179.06 1.76 4,179.06
0.75 0.15 0.25 4,178.81 12.00 4,178.81
0.75 0.14 0.13 4,178.67 16.28 4,178.67
0.75 0.12 0.18 4,178.49 27.04 4,178.49
0.75 0.12 0.23 4,178.26 48.01 4,178.26
0.75 0.11 0.27 4,177.99 56.99 4,177.99
4,121.00
0.75 0.11 0.30 4,120.70 10.20 4,120.70
0.75 0.05 0.11 4,120.59 25.21 4,120.59
0.75 0.05 0.07 4,120.52 26.87 4,120.52
4,178.67
0.75 0.01 0.01 4,178.67 40.24 4,178.67
4,120.70
0.75 0.01 0.00 4,120.70 7.20 4,120.70
4,179.06
0.75 0.09 0.21 4,178.85 14.81 4,178.85
0.75 0.08 0.13 4,178.71 19.04 4,178.71
0.75 0.08 0.13 4,178.59 17.00 4,178.59
0.75 0.07 0.08 4,178.51 17.73 4,178.51
0.75 0.05 0.02 4,178.49 22.67 4,178.49
0.75 0.04 0.06 4,178.43 52.35 4,178.43
0.75 0.04 0.04 4,178.39 55.20 4,178.39
4,123.19
0.75 0.04 0.04 4,123.15 10.02 4,123.15
4,178.85
0.75 0.01 0.00 4,178.85 19.85 4,178.85
HOJA DE CALCULO N 01
LINEA DE CONDUCCION 4
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
J-124 (CD-05) 4,062.00
J-125 4,061.23 0.100 0.04 7.7 0.54 0.75 0.13
J-126 4,055.62 0.100 0.04 62.2 0.35 0.75 0.13
RESERVORIO 4 4,050.22 0.115 0.04 99.6 0.32 0.75 0.13
RED DE DISTRIBUCION 4
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
RESERVORIO 4 4,050.22
J-56 4,047.77 0.027 0.02 89.8 0.27 0.75 0.08
J-58 4,038.85 0.224 0.02 50.8 0.31 0.75 0.08
J-59 4,032.35 0.254 0.02 69.7 0.29 0.75 0.08
J-56 4,047.77
CRP T7 - 05 4,009.00 0.230 0.03 178.8 0.28 0.75 0.12
CRP T7 - 05 4,009.00
HOJA DE CALCULO N 01
1.242
DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
1.30
2.00
Estimado
4,062.00
0.16 4,061.84 0.61 4,061.84
0.16 4,061.68 6.06 4,061.68
0.19 4,061.49 11.27 4,061.49
4,050.22
0.02 4,050.20 2.43 4,050.20
0.15 4,050.05 11.20 4,050.05
0.17 4,049.89 17.54 4,049.89
4,050.20
0.32 4,049.88 40.88 4,049.88
4,009.00
DE CALCULO N 01
LINEA DE CONDUCCION 5
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
J-52 (CD-03) 4,151.00
J-59 4,134.50 0.084 0.43 197.6 0.71 1.50 0.38
J-60 4,136.99 0.095 0.43 143.3 0.76 1.50 0.38
J-61 4,133.38 0.066 0.43 252.5 0.68 1.50 0.38
J-62 4,122.91 0.100 0.43 267.9 0.67 1.50 0.38
J-63 4,120.50 0.100 0.43 286.7 0.66 1.50 0.38
J-64 4,121.20 0.100 0.43 274.3 0.67 1.50 0.38
J-65 (CD-04) 4,120.00 0.034 0.43 836.4 0.53 1.50 0.38
J-65 (CD-04) 4,120.00
J-69 4,112.99 0.100 0.12 70.1 0.54 0.75 0.41
J-73 4,107.87 0.100 0.12 107.4 0.49 0.75 0.41
J-78 4,103.61 0.100 0.12 136.0 0.47 0.75 0.41
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 5
RESERVORIO 05 4,084.49
J-44 4,082.90 0.015 0.04 104.4 0.34 0.75 0.16
J-50 4,056.28 0.251 0.04 112.2 0.34 0.75 0.16
J-51 4,039.62 0.205 0.04 215.9 0.30 0.75 0.16
J-54 4,038.50 0.029 0.02 1,525.1 0.15 0.75 0.08
J-55 4,034.30 0.080 0.01 613.2 0.14 0.75 0.04
J-51 4,039.62
J-52 4,039.80 0.048 0.02 904.9 0.17 0.75 0.08
J-53 4,042.00 0.057 0.01 723.6 0.14 0.75 0.04
J-44 4,082.90 -
J-45 4,076.32 0.203 0.03 40.1 0.38 0.75 0.12
J-46 4,059.90 0.111 0.03 219.5 0.27 0.75 0.12
J-47 4,064.70 0.176 0.03 109.8 0.31 0.75 0.12
J-48 4,043.22 0.290 0.01 139.9 0.19 0.75 0.04
J-49 4,049.00 0.314 0.01 110.4 0.20 0.75 0.04
1.780
JA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
1.30
2.00
Estimado
4,151.00
0.44 4,150.56 16.06 4,150.56
0.50 4,150.05 13.06 4,150.05
0.35 4,149.70 16.32 4,149.70
0.53 4,149.17 26.26 4,149.17
0.53 4,148.63 28.13 4,148.63
0.53 4,148.10 26.90 4,148.10
0.18 4,147.92 27.92 4,147.92
4,120.00
1.39 4,118.61 5.62 4,118.61
1.39 4,117.21 9.34 4,117.21
1.39 4,115.82 12.21 4,115.82
JA DE CALCULO N 01
4,084.49
0.04 4,084.45 1.55 4,084.45
0.60 4,083.86 27.58 4,083.86
0.49 4,083.37 43.75 4,083.37
0.02 4,083.35 44.85 4,083.35
0.01 4,083.34 49.04 4,083.34
4,083.37
0.03 4,083.34 43.54 4,083.34
0.01 4,083.33 41.33 4,083.33
4,084.45
0.28 4,084.17 7.85 4,084.17
0.15 4,084.02 24.12 4,084.02
0.25 4,083.77 19.07 4,083.77
0.05 4,083.72 40.50 4,083.72
0.06 4,083.66 34.66 4,083.66
HOJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CD-06 4,095.00
J-92 4,089.50 0.100 0.07 55.0 0.45 0.75
J-94 4,084.77 0.100 0.07 97.5 0.40 0.75
J-95 4,081.80 0.100 0.07 122.4 0.39 0.75
J-98 4,080.30 0.100 0.07 132.6 0.38 0.75
J-99 4,078.06 0.100 0.07 150.2 0.37 0.75
J-101 4,075.33 0.100 0.07 172.7 0.36 0.75
J-104 4,060.26 0.100 0.07 318.6 0.32 0.75
J-105 4,063.97 0.100 0.07 276.7 0.33 0.75
J-106 4,065.00 0.100 0.07 261.6 0.33 0.75
J-109 4,048.49 0.100 0.07 421.9 0.30 0.75
J-110 4,041.53 0.100 0.07 486.7 0.29 0.75
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 6
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
RESERVORIO 4,029.68
J-63 4,020.17 0.143 0.10 66.5 0.51 0.75
J-64 4,016.53 0.268 0.09 43.3 0.54 0.75
J-67 4,006.88 0.305 0.04 62.1 0.38 0.75
J-68 3,991.83 0.240 0.04 138.5 0.33 0.75
J-69 3,987.82 0.109 0.04 336.3 0.27 0.75
J-64 4,016.53
J-65 4,006.00 0.198 0.04 100.4 0.35 0.75
J-66 3,990.05 0.089 0.04 397.9 0.26 0.75
CRP T7 - 06 3,980.00 0.198 0.04 228.4 0.29 0.75
CRP T7 - 06 3,980.00
J-92 3,971.00 0.051 0.04 177.1 0.31 0.75
J-93 3,972.50 0.028 0.02 262.0 0.22 0.75
J-95 3,953.93 0.190 0.01 136.2 0.19 0.75
J-94 3,940.00 0.194 0.01 205.5 0.18 0.75
J-93 3,972.50
J-96 3,961.24 0.213 0.01 87.6 0.21 0.75
J-97 3,946.85 0.216 0.01 153.0 0.19 0.75
J-98 3,937.10 0.196 0.01 217.6 0.18 0.75
2.638
OJA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
lt/seg
Estimado
4,095.00
0.23 0.48 4,094.52 5.02 4,094.52
0.23 0.48 4,094.04 9.27 4,094.04
0.23 0.48 4,093.56 11.76 4,093.56
0.23 0.48 4,093.08 12.78 4,093.08
0.23 0.48 4,092.60 14.54 4,092.60
0.23 0.48 4,092.12 16.79 4,092.12
0.23 0.48 4,091.64 31.38 4,091.64
0.23 0.48 4,091.16 27.19 4,091.16
0.23 0.48 4,090.68 25.68 4,090.68
0.23 0.48 4,090.20 41.71 4,090.20
0.23 0.48 4,089.72 48.19 4,089.72
OJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
CD-04 4,120.00
J-69 4,112.99 0.100 0.12 70.1 0.55 0.75 0.43
J-71 4,107.87 0.100 0.12 105.7 0.51 0.75 0.43
J-75 4,103.57 0.100 0.12 133.1 0.48 0.75 0.43
J-80 4,099.64 0.100 0.12 156.9 0.47 0.75 0.43
J-83 4,096.00 0.100 0.12 177.7 0.45 0.75 0.43
J-87 4,090.50 0.100 0.12 217.1 0.44 0.75 0.43
J-89 4,087.26 0.100 0.12 233.9 0.43 0.75 0.43
J-90 4,084.00 0.100 0.12 251.0 0.42 0.75 0.43
J-96 4,080.70 0.100 0.12 268.4 0.42 0.75 0.43
J-103 4,074.50 0.100 0.12 314.8 0.40 0.75 0.43
J-108 4,063.31 0.100 0.12 411.1 0.38 0.75 0.43
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 7
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM. VEL.
DINAMICO (KM) TRAMO (S) (") COMERC. FLUJO
RESERVORIO 07 4,014.25
J-72 4,007.50 0.090 0.12 75.3 0.54 0.75 0.43
J-73 3,996.41 0.122 0.01 134.4 0.19 0.75 0.04
J-75 3,974.07 0.241 0.01 160.7 0.19 0.75 0.04
J-72 4,007.50
J-74 4,005.50 0.027 0.11 328.3 0.39 0.75 0.39
J-78 3,964.73 0.247 0.02 198.9 0.23 0.75 0.08
J-74 4,005.50
J-76 4,001.65 0.082 0.09 150.1 0.42 0.75 0.31
J-77 4,001.50 0.081 0.07 144.5 0.38 0.75 0.24
J-79 3,978.70 0.136 0.03 251.3 0.26 0.75 0.12
J-81 3,964.05 0.140 0.03 346.0 0.24 0.75 0.12
J-77 4,001.50
J-80 3,996.11 0.179 0.03 93.0 0.32 0.75 0.12
J-82 3,989.26 0.111 0.03 209.0 0.27 0.75 0.12
J-83 3,970.60 0.197 0.01 211.8 0.18 0.75 0.04
J-82 3,989.26
J-83 3,982.13 0.062 0.02 485.8 0.19 0.75 0.08
1.716
DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
1.30
2.00
Estimado
4,120.00
1.56 4,118.44 5.45 4,118.44
1.56 4,116.88 9.01 4,116.88
1.56 4,115.33 11.76 4,115.33
1.56 4,113.77 14.13 4,113.77
1.56 4,112.21 16.21 4,112.21
1.56 4,110.65 20.15 4,110.65
1.56 4,109.10 21.84 4,109.10
1.56 4,107.54 23.54 4,107.54
1.56 4,105.98 25.28 4,105.98
1.56 4,104.42 29.92 4,104.42
1.56 4,102.86 39.55 4,102.86
DE CALCULO N 01
4,014.25
1.38 4,012.87 5.37 4,012.87
0.02 4,012.84 16.43 4,012.84
0.04 4,012.80 38.73 4,012.80
4,014.25
0.35 4,013.90 8.40 4,013.90
0.16 4,013.74 49.01 4,013.74
4,013.90
0.70 4,013.21 11.56 4,013.21
0.41 4,012.80 11.30 4,012.80
0.19 4,012.61 33.91 4,012.61
0.20 4,012.41 48.36 4,012.41
4,012.80
0.25 4,012.55 16.44 4,012.55
0.16 4,012.39 23.13 4,012.39
0.04 4,012.36 41.76 4,012.36
4,012.39
0.04 4,012.35 30.22 4,012.35
HOJA DE CALCULO N 01
LINEA DE CONDUCCION 8
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CD-07 4,035.00
J-140 4,023.50 0.109 0.04 105.4 0.34 0.75
J-141 4,014.50 0.100 0.04 202.5 0.30 0.75
J-143 4,005.00 0.100 0.04 295.3 0.28 0.75
CRP T6 - 03 3,985.62 0.100 0.04 486.8 0.25 0.75
CRP T6 - 03 3,985.62
J-146 3,971.00 0.100 0.04 146.2 0.32 0.75
J-147 3,958.47 0.100 0.04 269.2 0.28 0.75
J-148 3,950.00 0.100 0.04 351.7 0.27 0.75
CRP T6 - 04 3,935.00 0.078 0.04 639.3 0.24 0.75
CRP T6 - 04 3,935.00
CRP T6 - 05 3,890.00 0.121 0.04 372.4 0.26 0.75
CRP T6 - 05 3,890.00
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 8
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
RESERVORIO 08 3,870.82
J-109 3,854.25 0.100 0.07 165.5 0.37 0.75
J-110 3,853.75 0.070 0.01 236.0 0.17 0.75
J-109 3,854.25
J-111 3,844.68 0.128 0.06 199.7 0.33 0.75
J-112 3,854.02 0.071 0.01 222.2 0.17 0.75
J-111 3,844.68
J-113 3,826.58 0.181 0.04 239.6 0.29 0.75
J-115 3,825.26 0.063 0.01 700.8 0.14 0.75
J-113 3,826.58
J-114 3,825.18 0.026 0.03 1,730.4 0.17 0.75
0.639
OJA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
lt/seg
Estimado
4,035.00
0.15 0.25 4,034.75 11.25 4,034.75
0.15 0.23 4,034.53 20.03 4,034.53
0.15 0.23 4,034.30 29.30 4,034.30
0.15 0.23 4,034.07 48.45 4,034.07
3,985.62
0.15 0.23 3,985.39 14.39 3,985.39
0.15 0.23 3,985.17 26.70 3,985.17
0.15 0.23 3,984.94 34.94 3,984.94
0.15 0.18 3,984.76 49.76 3,984.76
3,935.00
0.15 0.27 3,934.73 44.73 3,934.73
3,890.00
OJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CD-08 3,987.00
J-152 3,973.55 0.092 0.07 145.4 0.39 0.75
J-153 3,956.74 0.100 0.07 297.2 0.33 0.75
J-154 3,944.76 0.100 0.07 411.2 0.31 0.75
CRP T6 - 06 3,934.00 0.059 0.07 863.2 0.27 0.75
CRP T6 - 06 3,934.00
J-155 3,926.91 0.041 0.07 174.7 0.37 0.75
J-156 3,917.68 0.100 0.07 160.8 0.38 0.75
J-157 3,912.59 0.100 0.07 205.9 0.36 0.75
J-158 3,903.70 0.100 0.07 289.0 0.34 0.75
RESERVORIO 09 3,895.24 0.100 0.07 367.7 0.32 0.75
HOJA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
lt/seg
Estimado
3,987.00
0.25 0.54 3,986.46 12.91 3,986.46
0.25 0.58 3,985.88 29.14 3,985.88
0.25 0.58 3,985.29 40.53 3,985.29
0.25 0.35 3,984.95 50.95 3,984.95
3,934.00
0.25 0.24 3,933.76 6.85 3,933.76
0.25 0.58 3,933.18 15.50 3,933.18
0.25 0.58 3,932.60 20.01 3,932.60
0.25 0.58 3,932.01 28.31 3,932.01
0.25 0.58 3,931.43 36.19 3,931.43
OJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CD-04 4,120.00
J-66 4,113.23 0.129 0.19 52.3 0.69 1.00
J-68 4,106.20 0.100 0.19 127.1 0.57 1.00
J-70 4,101.51 0.100 0.19 165.6 0.54 1.00
J-72 4,097.51 0.100 0.19 197.2 0.52 1.00
J-74 4,093.13 0.100 0.19 232.5 0.51 1.00
J-76 4,089.08 0.100 0.19 264.6 0.49 1.00
J-77 4,085.31 0.100 0.19 293.9 0.48 1.00
J-79 4,078.83 0.100 0.19 350.3 0.47 1.00
J-81 4,067.49 0.100 0.19 455.2 0.44 1.00
J-82 4,067.49 0.100 0.19 446.8 0.44 1.00
J-85 4,060.51 0.100 0.19 508.2 0.43 1.00
J-86 4,061.04 0.100 0.19 494.5 0.43 1.00
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 10
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
RESERVORIO 10 4,041.00
J-60 4,035.00 0.054 0.09 111.0 0.44 0.75
J-61 4,017.73 0.124 0.09 184.4 0.40 0.75
J-62 3,999.78 0.088 0.06 450.3 0.28 0.75
CRP T7 - 08 3,985.00 0.094 0.03 575.9 0.21 0.75
CRP T7 - 08 3,985.00
J-91 3,975.03 0.158 0.03 63.0 0.33 0.75
J-60 4,035.00
CRP T7 -09 3,996.50 0.238 0.15 185.4 0.48 0.75
CRP T7 -09 3,996.50
J-85 3,989.00 0.055 0.15 137.5 0.52 0.75
J-88 3,979.66 0.104 0.06 150.1 0.36 0.75
J-90 3,969.54 0.090 0.03 280.5 0.24 0.75
J-85 3,989.00
J-86 3,981.00 0.084 0.06 164.5 0.35 0.75
J-87 3,970.30 0.052 0.03 481.9 0.22 0.75
J-86 3,981.00
J-89 3,967.29 0.086 0.03 322.2 0.23 0.75
1.226
OJA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
Estimado
4,120.00
0.37 1.09 4,118.91 5.68 4,118.91
0.37 0.84 4,118.07 11.87 4,118.07
0.37 0.84 4,117.23 15.72 4,117.23
0.37 0.84 4,116.38 18.87 4,116.38
0.37 0.84 4,115.54 22.41 4,115.54
0.37 0.84 4,114.70 25.62 4,114.70
0.37 0.84 4,113.86 28.55 4,113.86
0.37 0.84 4,113.01 34.18 4,113.01
0.37 0.84 4,112.17 44.68 4,112.17
0.37 0.84 4,111.33 43.84 4,111.33
0.37 0.84 4,110.49 49.98 4,110.49
0.37 0.84 4,109.65 48.61 4,109.65
OJA DE CALCULO N 01
LINEA DE CONDUCCION
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
CD-05 4,062.00
J-129 4,061.00 0.100 0.09 10.0 0.74 0.75
J-133 4,057.50 0.100 0.09 35.5 0.57 0.75
J-134 4,051.27 0.100 0.09 88.3 0.47 0.75
J-135 4,043.50 0.100 0.09 156.5 0.42 0.75
J-136 4,032.64 0.100 0.09 255.7 0.38 0.75
J-137 4,018.00 0.100 0.09 392.6 0.35 0.75
J-138 4,000.00 0.100 0.09 563.1 0.32 0.75
CD-08 3,987.00 0.107 0.09 637.8 0.32 0.75
CD-08 3,987.00
J-149 3,968.00 0.100 0.02 190.0 0.23 0.75
J-150 3,957.81 0.100 0.02 291.3 0.21 0.75
RESERVORIO 11 3,950.25 0.096 0.02 381.7 0.20 0.75
HOJA DE CALCULO N 01
RED DE DISTRIBUCION 11
NUDO NIVEL LONG. Q DEL PENDIENTE DIAMETRO DIAM.
DINAMICO (KM) TRAMO (S) (") COMERC.
RESERVORIO 11 3,950.25
J-99 3,894.47 0.167 0.03 334.7 0.24 0.75
J-100 3,923.51 0.449 0.03 59.0 0.35 0.75
0.616
OJA DE CALCULO N 01
Fuente: INEI
ZONA SIERRA
K1= 1.30
K2= 2.00
Estimado
4,062.00
0.33 0.95 4,061.05 0.05 4,061.05
0.33 0.95 4,060.10 2.60 4,060.10
0.33 0.95 4,059.15 7.88 4,059.15
0.33 0.95 4,058.21 14.71 4,058.21
0.33 0.95 4,057.26 24.62 4,057.26
0.33 0.95 4,056.31 38.31 4,056.31
0.33 0.95 4,055.36 55.36 4,055.36
0.33 1.02 4,054.34 67.34 4,054.34
3,987.00
0.08 0.06 3,986.94 18.94 3,986.94
0.08 0.06 3,986.87 29.06 3,986.87
0.08 0.06 3,986.81 36.56 3,986.81
OJA DE CALCULO N 01