You are on page 1of 1

Flow meter description

Pipe size Flow rate (m3/hr.) Flange


Minimum Operating Maximum
Flow meter 1 3 22.5 30 33 3 C-300 flange
(12.5kg carousal) PN 25 or 50
Flow meter 2 3 4 5 {when 5kg filling} 33 3 C-300 flange
(5kg carousal) 15 {when 12.5kg filling} PN 25 or 50
Flow meter 3 2 2 7 13 2 C-300 flange
(37.5kg cylinder filling) PN 25 or 50
Flow meter 4 1 0.1 0.2 {Average} 0.5 1 C-300 flange
(2kg cylinder filling) 0.5 {when flow} PN 25 or 50

Note

5kg carousal normally used for the 5kg cylinder but it may be used for 12.5kg cylinders.
Operating flow rate can be varying with cylinder type that use to this carousal.
2kg cylinder filling machine not continues process. When consider one hour, average flow
rate can be taken. When consider one cylinder filling moment, flow rate is higher than
average flow rate.
Every flow meters will be install inside the plant.

Common conditions for all flow meters

Pressure

Minimum pressure : 6 bar


Operating pressure : 12 bar
Maximum pressure : 15 bar

Temperature

Minimum temperature : 100C


Operating temperature : 300C
Maximum temperature : 500C

Quality

70% butane 30% propane


Complete liquid phase