Professional Documents
Culture Documents
OT 100/120-277/700 P5
Benefits
High surge protection up to 6 kV;
Wide input voltage range: 120 277 V;
High efficiency and reliability;
High IP65
Applications
Street and Urban lighting
Industrial lighting
Suitable for luminaries of protection class I
Approval Marks
Housing material: metal, white
Product Features
1
OPTOTRONIC LED Power Supply OT 100/120-277/700 P5 Product Data Sheet
Electrical Specifications
Item Value Unit Remarks
Nominal voltage 120 277 Vac
Nominal frequency 50 / 60 Hz
AC voltage range 108 305 Vac
DC voltage range - Vdc
Maximum voltage 350 Vac For 2h maximum, see remark
113 277Vac
Nominal power 113 W 230Vac
116 120Vac
0.42 277Vac
Nominal current 0.49 A 230Vac
0.95 120Vac
INPUT
Total Harmonic Distortion (THD) < 10 % Full load, 230 V, 50 Hz / see graphs
Power factor > 0.95 Full load, 230 V, 50 Hz / see graphs
Efficiency 90.0 % Full load, 230 V, 50 Hz / see graphs
Power losses 12 W Full load, 230 V
No-load power NA W Load switching on the LED output is safe but not permitted
Stand-by power NA mW
Protection class I Housing must be connected to PE
Touch current < 0.35 mA pk according to EN 60598-1 Annex G and EN 61347-1 Annex A
Inrush current 100 A pk Max, th = 250 s
B25: TBD
Max. units per circuit breaker B16: TBD
B10: TBD
Nominal output voltage range 55 152 Vdc
Maximum output voltage 210 Vdc Abnormal load protection, constant output voltage
Nominal current range 700 mA Constant current 700mA
OUTPUT
Dimming range NA
Dimming technique NA
Galvanic isolation Interface NA
LEDset2 NA
NTC input NA
Constant Lumen Function NA
Ambient temperature range ta -40 +55 C Nominal Input Voltage: 120-277Vac
ENVIRONMENT / DIMENSIONS
*)
in preparation
Protections
Over temperature, Overload, No load, Short-circuit, Input overvoltage, Output Overvoltage, Output under voltage
See remarks on page 5.
Edition: May. 2015 Ver.: 1.0 Status: Released Misprints and technical changes excepted
OPTOTRONIC LED Power Supply OT 100/120-277/700 P5 Product Data Sheet
Wiring Diagram
Edition: May. 2015 Ver.: 1.0 Status: Released Misprints and technical changes excepted
OPTOTRONIC LED Power Supply OT 100/120-277/700 P5 Product Data Sheet
LED+/LED- < 10 m
[1] Typical Output current vs. Load [2] Typical Efficiency vs. Load
4
OPTOTRONIC LED Power Supply OT 100/120-277/700 P5 Product Data Sheet
Remarks
Input overvoltage protection: the driver withstands an input voltage up to 350 Vac for a maximum of two hours, shut down of the
output load might occur in case the supply voltage exceeds the declared input voltage range.
Output short circuit protection: short circuit current is limited to approx. 1 A without damage to the unit. See typical operating
window graph for details. Be sure the load is designed to withstand the short circuit current.
Output under voltage operation: the unit is not damaged if the load voltage is below the allowed minimum output voltage , but the
load current increases up to the short circuit value, see typical operating window graph for details. Be sure the load is safely
operated if this event might occur.
Output over load/voltage protection: In case the input voltage of the load exceeds the output voltage range of the driver, it
automatically reduces the output current. Auto-reversible without mains power on/off.
No load protection: the driver automatically adjusts the output voltage to the maximum output voltage if no load is connected. Auto-
reversible with the correct load connected;
Over temperature protection: the driver is protected against temporary overheating by shutting down until the overheating
eliminated; Auto-reversible when temperature back to normal
The protective earth ( GNYE/PE) wire should be connected to the heat sink of the LED module to improve the surge withstand
capability of the system and EMI in critical luminaries.
The startup time to reach the set output current is less than 2 s.
For further details please consult the application note
Standards
IEC 61347-1 Product name EAN10 EAN40 Pieces / box
IEC 61347-2-13 OT 100/120-277/700 P5 4052899259065 4052899259072 20
CISPR 15
IEC 61547
IEC 61000-3-2
IEC 61000-3-3
IEC 62384
FCC47 CFR part15
www.osram.com