MECHANICAL GROUP
REPORT 1
Drift force is used, instead of the wing profile in the apparatus.Drift coefficients
were calculated by placing different types of spikes on the wire. Three samples
were used for each type of plant. The air velocities were measured from the
bottom of the base with the speedometer in Figure 4.6; Experiments were carried
out at different air velocities at 13.5 m / s, 12 m / s, 11 m / s, 10 m / s, 8 m / s and
6 m / s.
The following formula is used to calculate the drift coefficient of the wheat plant
head.The drag force FD is measured and the drift coefficient for the known values
of , A and V is obtained.
F= CD AV2
The following equation is used to calculate the drag force of the system.
FDID = FGIG
Drift force is neglected because the wire is too thin for the drag force of the head.
FG is the weight of the additional mass m placed on the back of the ruler to
balance the body on the scale arm.
FG=mg
R = 287 J / kg.
MATERIALS USED IN THE EXPERIMENT
RESULTS
R=287 J/kg K
T=296,4 K
P=98925 Pa
A=7,59 cm2=7,59x10-4 m2
g=9.81 m/s2
ID=75mm=0,075 m
m=3,5 gr= 3,5x10-3 kg
CD=
Measurement 1
V= 34 km/h =34/3,6= 9.44444 m/s IG=29,5 mm=0,0295 m
20,029534,335103
CD= 9,4444420,0751,167,59104 =0,343934
Measurement 2
V= 37,8 km/h =37,8/3,6= 10,5 m/s IG=33 mm=0,033 m
20,03334,335103
CD= 10,5 20,0751,167,59104 =0,311272
Measurement 3
V= 40 km/h =40/3,6= 11,11111 m/s IG=36 mm=0,036 m
20,03634,335103
CD= 11,1111120,0751,167,59104 =0,303244
Discussion
The pressure of the faculty was found to be 762 mmHg = 101592 Pa = 1.0026
atm. The part is incorrectly measured. The pressure is inversely proportional to
the elevation. As the average increases every 10.5 meters, the pressure
decreases by 1mm.