You are on page 1of 12

Customer : AZU Manual : TSM

Type : A318/A319/A320/A321 Selected applicability : ALL


Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

** ON A/C ALL

TASK 24-00-00-810-818-A
Computer Reset

1. Possible Causes
2. Fault Confirmation
Subtask 24-00-00-710-059-A
A. Test
(1) Not applicable
3. Fault Isolation
Subtask 24-00-00-865-051-A
A. Table of the circuit breakers used in this procedure:

PANEL DESIGNATION FIN LOCATION


49VU FUEL/FQI/CHAN/1 1QT A13
49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07
49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06
49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05
49VU ENGINE/1/FADEC A/AND EIU 1 2KS1 A04
49VU FLIGHT CONTROLS/ELAC1/NORM/ 15CE1 B11
SPLY
49VU FLIGHT CONTROLS/FCDC1/SPLY 20CE1 B10
49VU FLIGHT CONTROLS/SEC1/NORM/SPLY 21CE1 B08
49VU AUTO FLT/FCU/1 9CA1 B05
49VU AUTO FLT/FAC1/28VDC 5CC1 B04
49VU AUTO FLT/FAC1/26VAC 14CC1 B03
49VU AUTO FLT/FMGC/1 10CA1 B02
49VU AUTO FLT/MCDU/1 11CA1 B01
49VU L/G/LGCIU/SYS1/NORM 1GA C09
49VU AIR COND/CAB/PRESS/CTL1 1HL D09
49VU AIR COND/TEMP CTL/SYS 1 CHAN 52HH D08
B/28VDC
49VU EIS/DMC1/SPLY 10WT1 E11
49VU FWS/FWC1/SPLY 3WW F01
49VU NAV/MMR/1 42RT1 G12
49VU COM/CIDS/DIR ESS/2 157RH G02
49VU COM/CIDS/DIR ESS/1 150RH G01
49VU COM/CIDS/FLT ATTND PNL/ESS 171RH H01
121VU COM NAV/RAD ALTM/2 1SA2 K12
121VU COM NAV/RAD ALTM/1 1SA1 K11
121VU T/TISS 2004SG K07
121VU APU/FIRE AND OVHT/DET/LOOP B 2WG L44
121VU APU/FIRE AND OVHT/DET/LOOP A 1WG L43
121VU FUEL/FQI/CHANNEL/1 AND 2 8QT L26
121VU ATSU 1 3TX1 L16
121VU ATSU 1/SWTG 5TX1 L15

Print Date: October 20, 2016 Page 1 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

PANEL DESIGNATION FIN LOCATION


121VU COM NAV/MMR/2 42RT2 L07
121VU HYDRAULIC/BRAKING AND STEER- 4GG M36
ING/SYS2/SPLY
121VU HYDRAULIC/BRAKING AND STEER- 3GG M35
ING/SYS2/CTL
121VU HYDRAULIC/BRAKING AND STEER- 1GG M34
ING/SYS1/CTL
121VU HYDRAULIC/BRAKING AND STEER- 2GG M33
ING/SYS1/IND AND/SPLY
121VU FUEL/FQI/CHAN/2 2QT M27
121VU AUTO FLT/FCU/2 9CA2 M21
121VU AUTO FLT/FAC2/28VDC 5CC2 M19
121VU AUTO FLT/FAC2/26VAC 14CC2 M18
121VU AUTO FLT/FMGC/2 10CA2 M17
121VU COM NAV/CIDS/DIR NORM/2 156RH M06
121VU COM NAV/CIDS/DIR NORM/1 151RH M05
121VU AUTO FLT/MCDU/2 11CA2 N20
121VU ENGINE/ENG2/FADEC B/AND EIU 2 4KS2 Q40
121VU ENGINE/ENG2/FIRE DET/LOOP A 7WD2 Q39
121VU ENGINE/ENG1/FIRE DET/LOOP B 8WD1 Q38
121VU HYDRAULIC/LGCIU/SYS2 2GA Q35
121VU HYDRAULIC/LGCIU/SYS1/GRND SPLY 52GA Q34
121VU FLIGHT CONTROLS/FCDC2/SPLY 20CE2 Q20
121VU FLIGHT CONTROLS/SEC3/SPLY 21CE3 Q19
121VU FLIGHT CONTROLS/SEC2/SPLY 21CE2 Q18
121VU COM/FAP1/NORM 170RH Q14
121VU EIS/DMC3/SPLY 10WT3 Q09
121VU EIS/DMC2/SPLY 10WT2 Q08
121VU EIS/FWC2/SPLY 2WW Q07
121VU ENGINE/ENG1/FADEC B/AND EIU 1 4KS1 R41
121VU FLIGHT CONTROLS/ELAC2/NORM/ 15CE2 R20
SPLY
122VU AIR COND/TEMP CTL SYS 2/CHAN 53HH W22
A/115VAC
122VU AIR COND/TEMP CTL SYS 2/CHAN 55HH W21
A/28VDC
122VU ANTI ICE/WHC/2 5DG2 W13
122VU AIR COND/TEMP CTL SYS 1/CHAN 49HH X22
A/115VAC
122VU AIR COND/TEMP CTL SYS 1/CHAN 51HH X21
A/28VDC
122VU ANTI ICE/WHC/1 5DG1 X13
122VU AIR COND/CAB PRESS/CTL/2 2HL Y22
122VU AIR COND/TEMP CTL SYS 2/CHAN 56HH Y21
B/28VDC
122VU AIR COND/TEMP CTL SYS 2/CHAN 54HH Y20
B/115VAC
122VU AIR COND/TEMP CTL SYS 1/CHAN 50HH Y18
B/115VAC
122VU AIR COND/AVNCS/VENT/MONG 3HQ Y17

Print Date: October 20, 2016 Page 2 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

PANEL DESIGNATION FIN LOCATION


2001VU VACU TOIL SYS-VACU-SYS 35MG A06
Subtask 24-00-00-810-069-A
B. Computer reset procedure

NOTE: This reset procedure is used when a computer does not operate correctly.

NOTE: The line maintenance personnel can use it a first time to avoid a computer replacement (a reset
must be done for the applicable computer as indicated in the Computer Reset Table). But, if there
is more than one reset for each flight cycle for a given computer, it is necessary to do the specif-
ic troubleshooting procedure for the applicable system. If after a reset, the computer operates cor-
rectly, no more action is necessary.

(1) To do computer reset:


(a) Set the related normal cockpit control to OFF, or open the related circuit breaker as specified in
the reset procedure.
(b) Wait 3 seconds if a normal cockpit control is used, or 5 seconds if a circuit breaker is used
(unless a different time is indicated).
(c) Set the related normal cockpit control to ON, or close the related circuit breaker.
(d) Wait 3 seconds for the end of the reset.
Subtask 24-00-00-810-075-E
C. Air Conditioning
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


21 CAB PR SYS 1(2) FAULT CABIN For CPC 1:
PRESSURE - On panel 49VU, open the
CONTROLLER circuit breaker 1HL.
(CPC) 1(2) FOR CPC 2:
- On panel 122VU, open the
circuit breaker 2HL.
After five seconds, close the
circuit breaker.
21 AIR FWD (AFT) CRG VENT CARGO On panel 49VU:
FAULT VENTILATION - Open the circuit breaker 31HN
CONTROLLER After five seconds, close the
circuit breaker.
21 VENT AVNCS SYS FAULT AVIONICS On panel 122VU:
EQUIPMENT - Open the circuit breaker 3HQ.
VENTILATION After five seconds, close the
COMPUTER circuit breaker.
21 AIR PACK 1(2) REGUL FAULT AIR COND For the ACSC 1:
SYSTEM - On panel 122VU, open
CONTROLLER the circuit breaker 49HH,
(ACSC) 1(2) circuit breaker 50HH
and circuit breaker 51HH.
- On panel 49VU, open
the circuit breaker 52HH.
Then close the circuit breakers.
For the ACSC2:

Print Date: October 20, 2016 Page 3 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


- On panel 122VU, open
the circuit breaker 53HH,
circuit breaker 54HH,
circuit breaker 55HH and
circuit breaker 56HH.
Then close the circuit breakers.
21 COND AFT CRG HEAT FAULT AFT CARGO On panel 49VU:
HEAT - Open the circuit breaker 31HN.
CONTROLLER - After five seconds, close
the circuit breaker.

Subtask 24-00-00-810-076-A
D. Auto Flight
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


22 AUTO FLT YAW DAMPER 1(2) FAC1(2) Open these C/Bs with the
FAULT Yellow and Green hydraulic
systems pressurized:
- for the FAC 1: on the
panel 49VU, C/B 5CC1
- for the FAC 2: on the
panel 121VU, C/B 5CC2
Then close the C/Bs after 10
seconds.
22 WINDSHEAR DET FAULT or FAC 1+2 Open then close the C/Bs in
REAC W/S DET FAULT this the order:
- on the panel 49VU, C/B
5CC1 and C/B 14CC1
- on the panel 121VU, C/B
5CC2 and C/B 14CC2.
22 AUTO FLT FCU 1(2) FAULT FCU For the FCU1:
- on the panel 49VU, open
the C/B 9CA1.
For the FCU2:
- on the panel 121VU, open
the C/B 9CA2.
Close the C/B after 5
seconds.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful).
If the fault continues, open
again the two C/Bs 9CA1
on 49VU and 9CA2 on 121VU.
Close the C/Bs after 7 min,
with an interval less than
5 sec between side 1 and
side 2.

Print Date: October 20, 2016 Page 4 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


At least 30 sec are necessary
until the end of the FCU1
and FCU2 safety test.
If the fault does not
continue, do a check of the
target and barometer
references shown, and
correct them if necessary
(reset successful)
If the fault continues, end
of procedure (reset
unsuccessful).
22 One MCDU locked or blank MCDU Open then close the C/B of
the defective MCDU after 10
seconds:
- For the MCDU1: on the
panel 121VU or panel 49VU,
C/B 11CA1.
- For the MCDU2: on the
panel 121VU, C/B 11CA2.
- For the MCDU3: on the
panel 121VU, C/B 11CA3.
22 FMGC malfunction FMGC On the panel 121VU or 49VU:
Both MCDUs locked or blank FMGC - open the FMGC 1 C/B 10CA1
and close it after 10
seconds.
When initiated engine
stopped
(aircraft in maintenance
configuration), the reset
will be followed by a
power-up test sequence of
around 90 seconds. During
this test sequence,
the system is unavailable.
If there is no reset of the
FMGC 1, do a reset of the
FMGC 2 on the panel 121VU:
- open the C/B 10CA2 and
close it after 10 seconds.

Subtask 24-00-00-810-077-D
E. Communications
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


23 COM CIDS 1+2 FAULT CIDS - Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH

Print Date: October 20, 2016 Page 5 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Uncommanded EVAC horn CIDS Press the EVAC/HORN SHUT
actuation OFF switch.
If unsuccessful:
- Open the C/Bs in this
order:
on the panel 49VU, C/B 150RH
on the panel 121VU, C/B
151RH
on the panel 49VU, C/B 157RH
on the panel 121VU, C/B
156RH
- After 10 seconds, close
the C/Bs in this order:
156RH, 157RH, 151RH and
150RH.
23 Frozen RMP RMP You must do a reset of all
the RMPs, one after the
other.
On the RMP control panel:
- set the ON/OFF switch to
OFF
- after 5 seconds, set the
ON/OFF switch to ON.
23 Frozen FAP FAP Open the C/Bs in this order:
On the panel 49VU, CB 171RH
On the panel 121VU, CB
170RH
- After 10 seconds, close
the C/Bs in this order:
170RH, 171RH
If unsuccessful:
on the panel 2000VU
- open the tape reproducer
/PRAM C/B 2RX.
After 10 seconds, close the
C/B.

Subtask 24-00-00-810-088-A
F. Electrical Power
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


24 GPU cannot be connected GAPCU If at least one power source
to the aircraft (IDG 1 or IDG 2, APU GEN or
batteries) is connected to
the electrical network of

Print Date: October 20, 2016 Page 6 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


the aircraft:
- On the ELEC control panel
35VU:
. Push and release the
EXT PWR pushbutton
switch.
If no power source is
connected to the electrical
network of the aircraft:
- On the ELEC control panel
35VU:
. Push the BAT 1 and BAT 2
pushbutton switches
(the OFF legend goes
off).

Subtask 24-00-00-810-079-A
G. Flight Controls
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


27 F/CTL ELAC 1(2) FAULT ELAC Reset the defective ELAC:
F/CTL ALTN LAW FAULT - Make sure that the
hydraulic systems are
depressurized before the
reset.
- Set the ELAC pushbutton
switch to OFF, then to ON.
27 ELAC or SEC malfunction ELAC or SEC Reset the defective ELAC:
- Make sure that the
hydraulic systems are
depressurized before the
reset.
Open, then close the C/B of
the defective ELAC or SEC.
For the ELAC 1(2):
- On the panel 49VU, C/B
15CE1.
- On the panel 121VU, C/B
15CE2.
For the SEC 1(2)(3):
- On the panel 49VU, C/B
21CE1.
- On the panel 121VU, C/B
21CE2 or 21CE3.
27 E/W FCDC1(2) FAULT FCDC On the panel 49VU:
- For FCDC1, open the C/B
20CE1.
- For FCDC2, open the C/B
20CE2.
- After 5 seconds, close
the C/Bs.

Print Date: October 20, 2016 Page 7 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

Subtask 24-00-00-810-089-A
H. Fuel
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


28 Loss of fuel quantity FQIC On the overhead circuit
indication or, breaker panel 49VU:
Simultaneous triggering - Open the C/B 1QT.
of FUEL L XFR VALVE On the rear circuit
CLOSED and FUEL R XFR breaker panel 121VU:
VALVE CLOSED, although - Open the C/Bs 2QT and 8QT.
FUEL SD indicates no After 5 seconds, close the
anomaly. three C/B's.

Subtask 24-00-00-810-080-A
J. Ice and Rain Protection
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


30 ANTI ICE WHC Open then close the C/B of
L(R)/WINSHIELD (WINDOW) the defective WHC.
For the WHC1:
- on the panel 122VU, C/B
5DG1.
For the WHC2:
- on the panel 122VU, C/B
5DG2.

Subtask 24-00-00-810-081-A
K. Indicating/Recording Systems
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


31 FWS FWC 1(2) FAULT FWC Open then close the C/B of
the defective FWC
For the FWC1:
- on the panel 49VU, C/B 3WW
For the FWC2:
- on the panel 121VU, C/B
2WW.
Wait 50 seconds after you
close the C/Bs.
31 EIS DMC 1(2)(3) FAULT DMC Open then close the
circuit breaker of
the defective DMC
For the DMC1:
- on the overhead C/B panel
49VU, the circuit breaker
10WT1.

Print Date: October 20, 2016 Page 8 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


For the DMC2:
- on the rear C/B panel
121VU, the circuit breaker
10WT2.
For the DMC3:
- on the rear C/B panel
121VU, the circuit breaker
10WT3.
31 CAPT PFD DU malfunction CAPT PFD DU On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
31 CAPT ND DU malfunction CAPT ND DU On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the CAPT lightning/loud
speaker control-panel 301VU,
turn the ND potentiometer
from the OFF position to
the BRT position.
31 F/O PFD DU malfunction F/O PFD DU On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,
turn the PFD potentiometer
from the OFF position to
the BRT position.
31 F/O ND DU malfunction F/O ND DU On the F/O lightning/loud
speaker control-panel 500VU,
turn the ND potentiometer
from the BRT position to
the OFF position.
- Wait for more than five
seconds.
On the F/O lightning/loud
speaker control-panel 500VU,

Print Date: October 20, 2016 Page 9 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


turn the ND potentiometer
from the OFF position to
the BRT position.
31 EWD malfunction EWD On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
BRT + position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the UPPER DISPLAY
potentiometer from the
OFF position to the BRT +
position.
31 SD malfunction SD On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
BRT position to the OFF
position.
- Wait for more than five
seconds.
On the ECAM control panel
turn the LOWER DISPLAY
potentiometer from the
OFF position to the BRT
position.

Subtask 24-00-00-810-082-A
L. Landing Gear
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


32 Braking malfunction BSCU On the panel 121VU:
- open the C/Bs 1GG, 2GG,
3GG and 4GG
- after 5 seconds, close
the CB's
32 L/G LGCIU 1(2) FAULT LGCIU 1(2) For the LGCIU 1:
- on the panel 121VU, open
the C/B 52GA then on 49VU,
C/B 1GA. After 15 seconds,
close the C/B 1GA and C/B
52GA
For the LGCIU 2:
- on the panel 121VU, open
the C/B 2GA. After 15
seconds, close the C/B 2GA

Subtask 24-00-00-810-083-D
M. Navigation

Print Date: October 20, 2016 Page 10 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


34 NAV MMR 1(2) FAULT MMR1(2) For the MMR 1:
- On the panel 49VU, open
the C/B 42RT1.
- After 5 seconds, close the
C/B.
For the MMR 2:
- On the panel 121VU, open
the C/B 42RT2.
- After 5 seconds, close the
C/B.
34 NAV TCAS FAULT T/TISS On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34 NAV GPWS FAULT T/TISS On the panel 121VU:
NAV GPWS TERR DET FAULT - Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34 NAV ATC/XPDR FAULT T/TISS On the panel 121VU:
- Open the C/B 2004SG.
- After 10 seconds, close
the C/B.
34 NAV GPS 1(2) FAULT GPSSU On the panel 121VU:
- For GPSSU1, open the C/B
2SN1.
- For GPSSU2, open the C/B
2SN2.
- After 5 seconds, close
the C/Bs.
34 NAV RA 1(2) FAULT XCVR-RA On the panel 121VU:
- For XCVR-RA 1, open the
C/B 1SA1.
- For XCVR-RA 2, open the
C/B 1SA2.
- After 5 seconds, close
the C/Bs.

Subtask 24-00-00-810-085-A
N. Information Systems
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


46 ATSU malfunction ATSU On the rear circuit
breaker panel 121VU:
- Open the C/Bs in this
order: 3TX1 and 5TX1.
- After 5 seconds, close
the C/Bs in this order:
5TX1 and 3TX1.

Print Date: October 20, 2016 Page 11 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : AZU Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : ALL
Rev. Date : Sep 19, 2016
24-00-00-810-818-A - Computer Reset

Subtask 24-00-00-810-086-A
P. Engine
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


70 ENG 1(2) IGN A + B FAULT FADEC and On the overhead circuit-breaker pan-
EIU el 49VU and rear circuit-breaker pan-
el 121VU, open then close the circuit
breakers of the defective FADEC.
For engine 1:
2KS1 and 4KS1.
For engine 2:
2KS2 and 4KS2.
70 ENG 1(2) FADEC A(B) FAULT FADEC On the overhead circuit-breaker pan-
el 49VU and rear circuit-breaker pan-
el 121VU, open then close the circuit
breakers of the defective FADEC.
For engine 1:
2KS1 and 4KS1.
For engine 2:
2KS2 and 4KS2.

Subtask 24-00-00-810-090-A
Q. Engine Indicating
(1) Computer Reset Table

ATA SYSTEM MALFUNCTION COMPUTER RESET PROCEDURE


77 Loss of N1VIB and N2VIB EVMU On the panel 121VU:
indications for ENG1(2) - Open the C/B 2EV.
in ECAM SD - After 5 seconds, close the
C/B.

End of document

Print Date: October 20, 2016 Page 12 of 12


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

You might also like