NATIONAL REFINERY LIMITED

PROJECTS DEPARTMENT
BILL OF QUANTITY
CONSTRUCTION OF SECOND FLOOR BUILDING AT BOILER NO.5
RATE AMOUNT
S.NO. DESCRIPTION QTY UNIT
Rs. Rs.
1 DISMANTLING/CHISELLING, REMOVAL AND DISPOSAL INSIDE NRL OF
RCC,PCC,BLOCK MASONRY ETC. COMPLETE IN ALL RESPECTS AND AS 300 CFT
INSTRUCTED BY THE ENGINEER.

2 EXCAVATION FOR STAIRCASE COLUMNS ETC. INCLUDING BACKFILLING AND


DISPOSAL. COMPLETE IN ALL RESPECTS AND AS INSTRUCTED BY THE 150 CFT
ENGINEER.

3 PROVIDING AND LAYING PLAIN CEMENT CONCRETE 1:4:8 FOR COLUMNS AND
STAIRCASE ETC. USING ONE PART ORDINARY PORTLAND CEMENT (FALCON
BRAND OR APPROVED EQUIVALENT) FOUR PARTS FINE SCREENED SAND
PASSING SIEVE NO.4 AND EIGHT PARTS 1 DOWN GAUGE GRADED CRUSHED
STONE AS COARSE AGGREGATE INCLUDING MIXING, LIFTING AND PLACING 100 CFT
USING FAIR FACE FORMWORK AND CURING ETC.. COMPLETE ALL AS DIRECTED
BY THE ENGINEER.

4 PROVIDING AND LAYING REINFORCED OR PLAIN CEMENT CONCRETE 1:2:4 FOR


BUILDING WORK AT FIRST FLOOR INCLUDING COLUMNS AND STAIRCASE ETC.
USING ONE PART ORDINARY PORTLAND CEMENT (FALCON BRAND OR
APPROVED EQUIVALENT) TWO PARTS FINE SCREENED SAND PASSING SIEVE NO.4
AND FOUR PARTS DOWN GAUGE GRADED CRUSHED STONE AS COARSE
AGGREGATE HAVING MINIMUM CONCRETE CUBE STRENGTH OF 3000 PSI AT 28
DAYS INCLUDING SCREENING AND WASHING OF AGGREGATES, MECHANICAL 3,000 CFT
MIXING, LIFTING AND PLACING TO ALL DEPTHS AND HEIGHT, VIBRATING USING
FAIR FACE FORMWORK AND CURING . COMPLETE ALL AS DIRECTED BY THE
ENGINEER.

5 PROVIDING AND LAYING REINFORCED OR PLAIN CEMENT CONCRETE 1:1.5:3 FOR


ELEVATED STRUCTURAL FRAME WORK WORK INCLUDING COLUMNS,SLABS,
BEAMS AND STAIRCASE ETC. USING ONE PART ORDINARY PORTLAND CEMENT
(FALCON BRAND OR APPROVED EQUIVALENT) ONE AND HALF PARTS FINE
SCREENED SAND PASSING SIEVE NO.4 AND THREE PARTS DOWN GAUGE
GRADED CRUSHED STONE AS COARSE AGGREGATE HAVING MINIMUM
CONCRETE CUBE STRENGTH OF 3750 PSI AT 28 DAYS INCLUDING SCREENING
AND WASHING OF AGGREGATES, MECHANICAL MIXING, LIFTING AND PLACING 3,001 CFT
TO ALL DEPTHS AND HEIGHT, VIBRATING USING STEEL OR PLY FORMWORK AND
SCAFOLDING ARRANGEMENT AND CURING WITH APPROVED CURING
COMPOUND . COMPLETE ALL AS DIRECTED BY THE ENGINEER.

6 PROVIDING AND LAYING 2.5 INCH THICK HEAT INSULATED ROOF TILES MAKE
CONEX OR APPROVED EQUIVALENT INCLUDINGMORTAR BED AND SEALING ALL
JOINTS WITH MORTAR IN 1:3 MIXED WITH PUDLO PROVIDING ADEQUATE
SLOPE . THE ITEM ALSO INCLUDED WITH ROOF DRAINAGE HD PVC PIPE 4 INCH 2,500 SFT
DIA x 2 NOS.COMPLETE ALL AS DIRECTED BY THE ENGINEER.

7 PROVIDING AND LAYING ROOF DRAINAGE HD PVC PIPE 4 INCH DIA INCLUDING
SOCKETS AND ALLIED WORK. COMPLETE ALL AS DIRECTED BY THE ENGINEER. 60 RFT

8 PROVIDING AND LAYING TOR STEEL REINFORCEMENT BAR GRADE 60 MAKE


RAZZAQ OR APPROVED SOURCE INCLUDING STRAIGHTENING, CUTTING,
BENDING, BINDING, WASTAGE , PLACING IN POSITION ON M.S, CHAIRS, TYING
WITH BINDING WIRES, ETC. IN ALL KINDS OF RCC WORK INCLUDING THE COST 10,000 KG
OF 18 GAUGE BINDING WIRES, CHAIRS, SPACERS ETC. COMPLETE IN ALL
RESPECTS AS PER DIRECTION OF THE ENGINEER.

9 PROVIDING AND LAYING AVERAGE 3 INCH THICK CONCRETE FLOOR IN SCREED


PCC 1:2:4 INCLUDING STEEL TROWEL SURFACE FINISHED WITH FLOOR
HARDENER @ 40 KG /100 SFT OF SIKA OR APPROVED MAKE ON CONSTRUCTED 1,200 SFT
BUILDING AREA COMPLETE WITH CURING. COMPLETE AS DIRECTED BY THE
ENGINEER

10 STAIRS RAILING WORKS WITH SQUARE IRON BARS 20 X 20 MM WITH


TOP RAIL 2 INCH DIA FOR STAIRS INCLUDING ALL MATERIAL AND
FABRICATION INCLUDING PRIMER AND FINISH COATINGS TO ALL 200 KG
ELEMENTS. COMPLETE ALL AS DIRECTED BY THE ENGINEER.

BILL OF QUANTITY
PAGE 1 OF 2
CONSTRUCTION OF SECOND FLOOR BUILDING AT BOILER NO.5
RATE AMOUNT
S.NO. DESCRIPTION QTY UNIT
Rs. Rs.

GRAND TOTAL Rs.

AMOUNT IN WORDS:

SIGN AND STAMP OF THE CONTRACTOR:

DATE: PLACE:

BILL OF QUANTITY
PAGE 2 OF 2
CONSTRUCTION OF SECOND FLOOR BUILDING AT BOILER NO.5