You are on page 1of 182

SCHEDULE OF QUANTITIES

Name of Work: C/o Annexe Building (Basement, G+2) of NABARD at Sector-34 A, Chandigarh including Internal Water Supply, Sanitary Installations Drainage an
Passenger Lifts, Security and Compound Lighting etc.

Name of contractor:-

Rate
Item No. Description of Items Qty Unit
(In figures)

SCHEDULE OF QUANTITIES (Civil Work)


SubHead: EARTH WORK

1.1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding
30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m
and lift upto 1.5m, disposed earth to be levelled and neatly dressed.

1.1.1 All kinds of soil


7150 cum

1.2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or
drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift
upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a
lead of 50 m.

1.2.1 All kinds of soil.


64 cum

1.3 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of
sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil
as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming,
watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :

1.3.1 All kinds of soil


1.3.1.1 Pipes, cables etc, not exceeding 80 mm dia.
35 metre

1.3.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
400 metre

1.3.1.1 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm
75 metre
Rate
Item No. Description of Items Qty Unit
(In figures)

1.4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not
exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift
362 cum
upto 1.5 m.

1.5 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.

1.5.1 All kinds of soil


4632 cum

SubHead: CONCRETE WORK

2.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
2.1.1 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

298 cum

2.2 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and
consolidated and grouted with fine sand, including finishing the top smooth. 115 sqm

SubHead: REINFORCED CEMENT CONCRETE

3.1 Centering and shuttering including strutting, propping etc. and removal of form for :

3.1.1 Foundations, footings, bases of columns, etc. for mass concrete


390 sqm

3.1.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
3624 sqm

3.1.3 Suspended floors, roofs, landings, balconies and access platform


5822 sqm

3.1.4 Lintels, beams, plinth beams, girders, bressumers and cantilevers


3760 sqm

3.1.5 Columns, Pillars, Piers, Abutments, Posts and Struts


1890 sqm
Rate
Item No. Description of Items Qty Unit
(In figures)
3.1.6 Stairs, (excluding landings) except spiral-staircases
118 sqm

3.2 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all
complete upto plinth level.
3.2.1 Thermo-Mechanically Treated bars
146376 kilogram

3.3 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all
complete above plinth level.
3.3.1 Thermo-Mechanically Treated bars
470300 kilogram

3.4 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete
for reinforced cement concrete work, using cement content as per approved design mix, including pumping of
concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including
admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve
workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement
content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/
recoverable separately).

3.4.1 All works upto plinth level


1331 cum

3.4.2 All works above plinth level upto floor V level


2925 cum

3.5 Providing and fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints.

3.5.1 300 mm wide.


26 metre

3.6 Providing and fixing unplaticised rigid PVC pipes in sleeves in RCC beams for rain water pipes/ other services.

3.6.1 150mm dia


20 metre

3.6.2 100mm dia


10 metre
Rate
Item No. Description of Items Qty Unit
(In figures)
3.6.3 50mm dia
10 metre

SubHead: BRICK WORK

4.1 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course in non- modular fly ash
lime half bricks walls (FALG Bricks). 775 sqm

4.2 Brick work with non modular fly ash lime bricks (FALG Bricks) conforming to IS:12894, class designation 10
average compressive strength in super structure above plinth level up to floor V level in :

4.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand)


116 cum

4.3 Providing and laying autoclaved aerated cement blocks masonry with AAC blocks in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing
in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 243 cum

4.4 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 115 metre

4.5 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in
cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 500 each

4.6 Stone work, plain in copings, cornices, string courses and plinth courses, upto 150 mm thick in Cement mortar
1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust)
with an admixture of pigment matching the stone shade including making the key grooves to support the Dholpur
stone cladding.

4.6.1 Dholpur stone


120 cum

4.7 Stone work (machine cut edges Veneer work) for wall lining upto 10 m height, backing filled with a grout of 12
mm thick cement mortar 1:3 (1 Cement : 3 coarse sand) and jointed with Cement mortar 1:2 (1 cement : 2 stone
dust), including rubbing and polishing complete. (To be secured to the backing and the sides by means of
cramps and pins which shall be paid for separately).
Rate
Item No. Description of Items Qty Unit
(In figures)
4.7.1 40 mm thick Dholpur stone slabs exposed face dressed and rubbed.
1684 sqm

4.8 Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every
additional height of 3 m or part there of. 400 sqm

SubHead: MARBLE WORK

5.1 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade,
colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing
to edges to give high gloss finish etc. complete at all levels.

5.1.1 Granite of any colour and shade


5.1.1.1 Area of slab over 0.50 sqm
17 sqm

5.2 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity
counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including
moulding, rubbing and polishing of cut edges etc. complete. 25 each

5.3 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8
cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the
stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.

5.3.1 Granite Stone of approved shade


5 sqm

SubHead: WOOD AND P.V.C WORK

6.1 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand
logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to
1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 48 each
Rate
Item No. Description of Items Qty Unit
(In figures)
6.2 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out
of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of
15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of
19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to
117 metre
the wall using M.S. screws of 65/100 mm size, complete as per manufacturers specification and direction of
Engineer-in-Charge.

6.3 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19
gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall
have a coat of steel primers of approved make and manufacture.M.S. frame covered with 5 mm thick heat
moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm
shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of
which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail
and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form
lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm
wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC
sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm
wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm
thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive
etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.

6.3.1 30 mm thick pre laminated PVC door shutters


39 sqm

6.4 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG
G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for
mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm
(minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat
of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be 47 metre
paid for separately).

6.5 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to
IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting
on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of
16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with
necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire 17 sqm
resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Rate
Item No. Description of Items Qty Unit
(In figures)
6.6 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I.
beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant
sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per
direction of Engineer-in-charge.

6.6.1 With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance
17 sqm

6.7 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of
block board construction with frame of 1st class hard wood and well vertical grains or cross bands and face
veneer on both faces of shutters, providing lipping with 2nd class teak wood battens 6mm thick on all edges of
shutters and providing & fixing 1mm thick decorative high pressure laminated sheet on both faces of shutter, of
plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of
adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality.

6.7.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
162 sqm

6.8 Providing and fixing stainless steel tower bolt (Barrel type) with necessary screws etc. complete :

6.8.1 250x10 mm
118 each

6.8.2 150x10 mm
97 each

6.9 Providing and fixing stainless steel handles with screws with necessory screws etc. complete :

6.9.1 125 mm
236 each

6.10 Providing and fixing Stainless Steel hanging floor door stopper with necessary screws etc. complete.

6.10.1 Twin rubber stopper


95 each
Rate
Item No. Description of Items Qty Unit
(In figures)
6.11 Providing and fixing stainless steel sliding door bolts with nuts and screws etc. complete :

6.11.1 300x16 mm
21 each

6.11.2 250x16 mm
53 each

6.12 Providing and fixing stainless steel pull bolt lock, with necessary screws bolts, nut and washers etc. complete.
42 each

SubHead: STEEL WORK

7.1 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset
plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved
steel primer.
7.1.1 Using M.S. angels 40x40x6 mm for diagonal braces
2 sqm

7.2 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together
through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft
with brackets, side guides and arrangements for inside and outside locking with push and pull operation
complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high
tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness
for rolling shutters.

7.2.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover


12 sqm

7.3 Providing and fixing ball bearing for rolling shutters.


4 each
Rate
Item No. Description of Items Qty Unit
(In figures)
7.4 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including
welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless
steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab
with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless 950 kg
steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Rate
Item No. Description of Items Qty Unit
(In figures)
SubHead: FLOORING

8.1 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick
cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size)
by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specifications. 1435 sqm
This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

8.2 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a
floating coat of neat cement.
8.2.1 18 mm thick
27 sqm

8.3 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge,
over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey
cement slurry, including rubbing and polishing complete with :

8.3.1 Agaria White


91 sqm

8.4 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed
with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement : 4 coarse sand) :

8.4.1 25 mm thick
370 sqm

8.5 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement
mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade
of the slabs, including rubbing and polishing complete. 40 sqm

8.6 Providing and fixing Ist quality ceramic glazed wall tiles of size 250mmx350mm conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle
green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
568 sqm
including pointing in white cement mixed with pigment of matching shade complete.
Rate
Item No. Description of Items Qty Unit
(In figures)
8.7 Providing and laying rectified Glazed Ceramic floor tiles of size 400mmx400 mm or more (thickness to be
specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades,
except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse
sand), including pointing the joints with white cement and matching pigments etc., complete. 338 sqm

8.8 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on
20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and
matching pigments etc., complete.

8.8.1 Size of Tile 605x605 mm


1156 sqm

8.9 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water
absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting,
riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint
with white cement & matching pigments etc. complete.

8.9.1 Size of Tile 605x605 mm

116 sqm

8.10 Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks of required strength,
thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over
50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks
into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna
sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath,
parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer's specifications & direction of 210 sqm
Engineer- in-Charge. 60mm thick C.C. paver block of M-35 grade with approved colour, design & pattern.

8.11 Granite stone flooring with 16mm thick granite stone (as per sample approved by Engineer-in-charge) over
20mm thick (average) base of cement mortar 1:4 (1cement :4 coarse sand) laid with grey cement slurry & jointed
with white cement slurry mixed with pigment to match the granite colour or shade all complete.
Rate
Item No. Description of Items Qty Unit
(In figures)
8.11.1 Granite stone (polished) any colour or shade.
442.00 Sqm

8.11.1 Granite stone (flamed) any colour or shade.


61.00 Sqm

8.12 Providing and laying 16 mm thick (average) granite stone (as per sample approved by Engineer-in-charge) for
wall dados, skirting, risers of steps, laid on 12 mm thick (average) base of cement mortar 1 : 3 (1 Cement : 3
coarse Sand) including jointing with white cement slurry mixed with pigment to match the shade of stone
165 sqm
complete.

8.13 Providing and fixing wooden laminated flooring AC-4 (Grooveless) 10.3 mm thick (8.3mm thick wood at top and
2mm silent pro at bottom) conforming to European standard of high density fiber board (HDF EI) core with design
layer on top protected by a high wear and scratch resistant over lay of laminated wooden panels to reduce the
room sound i/c under layer of transparent polythene layer of at least 30micron thick and 2mm thick foam of
380 Sqm
superior quality etc. all complete as per the direction of Engineer-in-charge.

SubHead: ROOFING

9.1 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single
socketed pipes.
9.1.1 110 mm diameter
120 metre

9.2 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC
rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving
10 mm gap for thermal expansion.

9.2.1 Bend 87.5


9.2.1.1 110 mm bend
5 each

9.2.2 Shoe (Plain)


9.2.2.1 110 mm Shoe
11 each
Rate
Item No. Description of Items Qty Unit
(In figures)
9.3 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less
than 440 grams. 11 each

9.4 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level,
suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm,
both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size
24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size
24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center
to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of
0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600
mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including,
required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.

Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to
ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level
clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24
mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications,
drawings and as directed by Engineer-in-charge.

9.4.1 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard,
manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant
PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face
side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized 3474 sqm
polyester film so as to make the tile a completely sealed unit.

9.4.2 3 mm thick translucent white acrylic plastic sheets of approved quality in false ceiling of size 595x595mm
338 sqm

9.5 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) >
78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm
thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white
cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, 1430 sqm
including providing skirting upto 150 mm height along the parapet walls in the same manner.
Rate
Item No. Description of Items Qty Unit
(In figures)
9.6 Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane
foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of
polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a
wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm
nominal size) in chequered rough finish, in panels of 2.5mx2.5m and embedding with 24 G wire netting and
sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge. 1430 sqm

SubHead: FINISHING

10.1 12 mm cement plaster of mix :


10.1.1 1:6 (1 cement: 6 coarse sand)
1930 sqm

10.2 15 mm cement plaster on rough side of single or half brick wall of mix :
10.2.1 1:6 (1 cement: 6 coarse sand)
1930 sqm

10.3 6 mm cement plaster of mix :


10.3.1 1:3 (1 cement : 3 fine sand)
12580 sqm

10.4 White washing with lime to give an even shade :


10.4.1 New work (three or more coats)
2435 sqm

10.5 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :

10.5.1 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer
applied @ 2.20 kg/ 10 sqm) 380 sqm

10.6 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :

10.6.1 Two or more coats on new work


16440 sqm

10.7 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even
shade :
Rate
Item No. Description of Items Qty Unit
(In figures)
10.7.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and
manufacture 26 sqm

10.8 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 18875 sqm

SubHead: SANITARY INSTALLATIONS

11.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and
stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls
wherever required :
11.1.1 Kitchen sink with drain board
11.1.1.1 510x1040 mm bowl depth 250 mm
2 each

11.2 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.

11.2.1 Semi rigid pipe


11.2.1.1 40 mm dia
18 each

11.3 Providing and fixing soil, waste and vent pipes :


11.3.1 100 mm dia
11.3.1.1 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
300 metre

11.3.2 75 mm diameter :
11.3.2.1 Centrifugally cast (spun) iron socketed pipe as per IS: 3989
255 metre

11.4 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe
embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :

11.4.1 For 100 mm dia pipe


70 each

11.4.2 For 75 mm dia pipe


60 each
Rate
Item No. Description of Items Qty Unit
(In figures)
11.5 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and
nuts complete.
11.5.1 100 mm dia
11.5.1.1 Sand cast iron S&S as per IS - 3989
21 each

11.5.2 75 mm dia
11.5.2.1 Sand cast iron S&S as per IS- 3989
18 each

11.6 Providing and fixing plain bend of required degree.


11.6.1 100 mm dia
11.6.1.1 Sand cast iron S&S as per IS : 3989
7 each

11.6.2 75 mm dia
11.6.2.1 Sand cast iron S&S as per IS - 3989
6 each

11.7 Providing and fixing heel rest sanitary bend


11.7.1 100 mm dia
11.7.1.1 Sand cast iron S&S as per IS - 3989
7 each

11.7.2 75 mm dia
11.7.2.1 Sand cast iron S&S as per IS - 3989
6 each

11.8 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3
mm thick, bolts and nuts complete.
11.8.1 100x100x100 mm
11.8.1.1 Sand cast iron S&S as per IS - 3989
21 each

11.8.2 75x75x75 mm
11.8.2.1 Sand cast iron S&S as per IS - 3989
18 each

11.9 Providing and fixing terminal guard :


11.9.1 100 mm
11.9.1.1 Sand cast iron S&S as per IS - 3989
7 each

11.9.2 75 mm
Rate
Item No. Description of Items Qty Unit
(In figures)
11.9.2.1 Sand cast iron S&S as per IS - 3989
6 each

11.10 Providing and fixing collar :


11.10.1 100 mm
11.10.1.1 Sand cast iron S&S as per IS - 3989
20 each

11.10.2 75 mm
11.10.2.1 Sand cast iron S&S as per IS - 3989
20 each

11.11 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter :

11.11.1 100 mm
140 each

11.11.2 75 mm
120 each

11.12 Providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter :

11.12.1 100 mm
7 each

11.12.2 75 mm
6 each

11.13 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm
complete, including cost of cutting and making good the walls and floors :

11.13.1 100 mm inlet and 75 mm outlet


11.13.1.1 Sand cast iron S&S as per IS - 3989
42 each

11.14 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 570 x
320 x 280 mm having pre & post flushing with water (250 ml & 350 ml consumption), having water inlet from back
side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of
Engineer-in-charge. 16 each
Omega E-Sense Cat. No.: 96006, parryware or equivalent
Rate
Item No. Description of Items Qty Unit
(In figures)

11.15 Providing and fixing toilet paper holder of Jaquar make Cat. No. ACN 1153 N or equivalent with necessary
screws/ rawl plugs as per direction of Engineer-in-charge :

11.15.1 C.P. brass


22 each

11.16 Extra for providing/ fixing anti-cockroach grating of 100mm dia instead of GI grating in floor trap.
42 each

11.17 Providing and fixing white vitreous china extended wall mounting water closet of size 690x350x630 mm of
approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity
2 litre/4 litre, including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Rubbic EWC Cat. No.: 92064, parryware or equivalent 22 each
Rubbic Cistern Cat . No.: 92124, parryware or equivalent

11.18 Providing and fixing 100mm diameter Stainless Steel (of minimum grade 304) grating (jali with frame) for gully,
floor or Nahani trap of the make as approved by the Engineer-in-Charge. 42 each

11.19 Providing and fixing Soap dispenser with metalic bottle of Jaquar Category No.1137N or equivelent fixed with
necessary stainless steel screws as per direction of Engineer-in-charge. 25 each

11.20 Providing and fixing Float Glass Mirror of minimum 6mm thickness, of required shape and size of "Modiguard"/
"Saint Gobain" make, with 6mm thick water proof ply wood board backing conforming ot IS 710 including making
necessary holes in the mirror, if required. The ply wood board shall be rigidly fixed to the wall using required
stainless steel screws, rawl plugs etc. The mirror shall be fixed to the ply wood board backing using necessary
CP brass screws and alround moulded beading of 25x25mm, made out of teak wood using epoxy adhesive
mitred joints etc. all complete, as per the architectural drawings, as specified and as directed by the Engineer-in-
17 sqm
Charge. (The rate of the item includes cost of all inputs of labour, material, T&P, all other incidental charges
involved in the work. For the purpose of payment, the actual area of the mirror shall be measured in sqm.)

11.21 Providing and fixing 1st quality white vitreous china under counter oval shape wash basin of parryware or
equivalent of size 550x400 with C.I. bracket i/c painting of fittings and central hole C.P. brass mixer of Jaquar
(Queen's Series Cat. No. 7167 B GA) or equivalent make, 32mm waste coupling of Jaquar Cat. No. ALD 709 or
equivalent including C.P. boottle trap of Jaquar Cat. No. ALD 769 and pipe of Jaquar or equivalent make to wall
with CP brass flange and rubber stoper complete i/c cutting and making good the walls wherever required as per 25 each
the direction of the Engineer-in-Charge.
Rate
Item No. Description of Items Qty Unit
(In figures)

11.22 Providing and fixing CP brass towel ring fixed to wooden cleats with CP brass screws complete as per direction
of Engineer-in-charge. (Jaquar make Cat. No. AQN 7721 or equivalent) 13 each
Rate
Item No. Description of Items Qty Unit
(In figures)
SubHead: WATER SUPPLY

12.1 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.

12.1.1 50 mm dia nominal bore


35 metre

12.1.2 80 mm dia nominal bore


153 metre

12.2 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee,
including cutting and threading the pipe etc. complete:
12.2.1 50 to 80 mm nominal bore
1 each

12.3 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

12.3.1 32 mm nominal bore.


4 each

12.3.2 40 mm nominal bore


4 each

12.3.3 50 mm nominal bore


2 each

12.3.4 80 mm nominal bore 2 each

12.4 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

12.4.1 20 mm nominal bore


2 each

12.5 Providing and fixing uplasticised PVC connection pipe with brass unions :
12.5.1 45 cm length
12.5.1.1 15 mm nominal bore
55 each
Rate
Item No. Description of Items Qty Unit
(In figures)
12.6 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse
sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete
slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary
excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size)
and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat
of neat cement complete as per standard design :

12.6.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
2 each

12.7 Providing and filling sand of grading zone V or coarser grade, all- round the G.I. pipes in external work :

12.7.1 50 mm diameter pipe


35 metre

12.7.2 80 mm diameter pipe


153 metre

12.8 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with
cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but
without fittings and the base support for tank. 20000 per litre

12.9 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with
press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including
cutting and making good the walls including testing of joints complete as per direction of Engineer -in-charge.
(The pipe length inserted in the fitting shall not be measured for payment) Inernal work - Exposed on wall

12.9.1 15.88 mm outer dia pipe


14 metre

12.9.2 22.22 mm outer dia Pipe


14 metre

12.9.3 28.58 mm outer dia Pipe


14 metre

12.9.4 34.00 mm outer dia Pipe


154 metre

12.9.5 48.60 mm outer dia Pipe


50 metre
Rate
Item No. Description of Items Qty Unit
(In figures)

12.10 Providing and fixing Stainless Steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with
press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00m spacing and also
including cutting of chases and making good the walls including testing of joints complete as per direction of
Engineer -in-charge. (The pipe length inserted in the fitting shall not be measured for payment).
Internal work - Concealed Pipe

12.10.1 15.88 mm outer dia .Pipes.


60 metre

12.10.1 22.22 mm Outer dia pipes


180 metre

12.11 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.

12.11.1 For 15.88 mm outer dia pipe


20 each

12.11.2 For 22.22 mm outer dia pipe


65 each

12.11.3 For 28.58 mm outer dia pipe


5 each

12.11.4 For 34.00 mm outer dia pipe


52 each

12.11.5 For 48.60 mm outer dia pipe


15 each

12.12 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming toJWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.

12.12.1 For 22.22 mm x 15.88 mm outer dia pipe


10 each

12.12.2 For 28.58 mm x 15.88 mm outer dia pipe


5 each

12.12.3 For 28.58 mm x 22.22 mm outer dia pipe


5 each
Rate
Item No. Description of Items Qty Unit
(In figures)
12.12.4 For 34.00 mm x 22.22 mm outer dia pipe
5 each

12.12.5 For 34.00 mm x 28.58 mm outer dia pipe


4 each

12.12.6 For 48.60 mm x 28.58 mm outer dia pipe


4 each

12.12.7 For 48.60 mm x 34.00 mm outer dia pipe


4 each

12.13 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.

12.13.1 For 15.88 mm outer dia pipe


14 each

12.13.2 For 22.22 mm outer dia pipe


16 each

12.13.3 For 28.58 mm outer dia pipe


12 each

12.13.4 For 34.00 mm outer dia pipe


4 each

12.13.5 For 48.60 mm outer dia pipe


4 each

12.14 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.

12.14.1 For 15.88mm outer dia pipe


20 each

12.14.2 For 22.22 mm outer dia pipe


30 each

12.14.3 For 28.58 mm outer dia pipe


4 each

12.14.4 For 34.00 mm outer dia pipe


4 each
Rate
Item No. Description of Items Qty Unit
(In figures)
12.14.5 For 48.60 mm outer dia pipe
18 each

12.15 Providing and fixing required Stainless Steel Fitting of press fit design of grade AISI 304 conforming to JWWA
G116 standard with V-profile or M-profile and with O-ring sealing gasket of EPDM material of required dia as per
direction of Engineer-in-charge.

12.15.1 For 15.88 mm outer dia pipe


10 each

12.15.2 For 22.22 mm outer dia pipe


15 each

12.15.3 For 28.58 mm outer dia pipe


4 each

12.15.4 For 34.00 mm outer dia pipe.


4 each

12.15.5 For 48.60 mm outer dia pipe


4 each

12.16 Providing and fixing CP Brass over head shower multiflow 120mm dia (ABS Chromplated) without shower arm of
Jaquar Make category No.1799 GB or equivalent complete in all respect. 1 each

12.17 Providing and fixing C.P. brass bib cock of Jaquar queens collection of category 7037 GA or equivalent approved
quality conforming to IS standards and weighing not less than 810 gms.

12.17.1 15 mm nominal bore.


41 each

12.18 Providing and fixing CP Brass angle valve for basin mixer and geyser points of category 7053 series Jaquar or
equivalent queen's collection

12.18.1 15mm nominal bore.


77 each

12.19 Providing and fixing CP Brass shower arm 190mm long light body wall flenge of Jaquar Make category No.477 or
equivalent complete in all respect. 1 each

SubHead: DRAINAGE
Rate
Item No. Description of Items Qty Unit
(In figures)

13.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the
proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :

13.1.1 150 mm diameter


60 metre

13.1.2 200 mm diameter


18 metre

13.1.3 250 mm diameter


61 metre

13.1.4 300 mm diameter


146 metre

13.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm
nominal size) all-round S.W. pipes including bed concrete as per standard design :

13.2.1 150 mm diameter S.W. pipe


60 metre

13.2.2 200 mm diameter S.W. pipe


18 metre

13.2.3 250 mm diameter S.W. pipe


61 metre

13.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm
nominal size) up to haunches of S.W. pipes including bed concrete as per standard design :

13.3.1 300 mm diameter S.W. pipe


57 metre

13.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber
with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg
and frame to be not less than 2.70 kg as per standard design :

13.4.1 150 x 100 mm size P type


13.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
2 each
Rate
Item No. Description of Items Qty Unit
(In figures)
13.5 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

13.5.1 300 mm dia. R.C.C. pipe


100 metre

13.6 Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with
1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8
mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making
channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
finished with a floating coat of neat cement complete as per standard design :

13.6.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame
15 kg) :
13.6.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4 each

13.6.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter,
total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :

13.6.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
9 each

13.7 Extra for depth for manholes :


13.7.1 Size 90x80 cm
13.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1 metre

13.7.2 Size 120x90 cm


13.7.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5 metre
Rate
Item No. Description of Items Qty Unit
(In figures)
13.8 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement
mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4
(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :

13.8.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering
all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for
separately) :

13.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1 each

13.9 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m

13.9.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1 metre

13.10 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement
mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat
cement, all complete as per standard design :

13.10.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering
all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for
separately) :

13.10.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1 each

13.11 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m :
Rate
Item No. Description of Items Qty Unit
(In figures)
13.11.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1 metre

13.12 Making connection of drain or sewer line with existing manhole including breaking into and making good the
walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a
floating coat of neat cement and making necessary channels for the drain etc. complete :

13.12.1 For pipes 100 to 250 mm diameter


2 each

13.13 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame and vertical grating complete
as per standard design :

13.13.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
7 each

13.14 Extra for depth beyond 45 cm of brick masonry chamber :


13.14.1 For 600x850 mm size
13.14.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
3 metre

SubHead: ALUMINIUM WORK

14.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:
1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e.
at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth,
rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and
the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

14.1.1 For fixed portion


14.1.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron)
1520 kg
Rate
Item No. Description of Items Qty Unit
(In figures)
14.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost
of aluminium snap beading shall be paid in basic item):

14.2.1 With float glass panes of 4.0 mm thickness


9 sqm

14.2.2 With float glass panes of 5.50 mm thickness


25 sqm

14.3 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS
screws etc .complete as per direction of Engineer-in-Charge.
14.3.1 Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
2 each

14.4 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture,
including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes
etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and
5 sqm
stopper etc.to be paid separately).

SubHead: WATER PROOFING

15.1 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below
ground level for under ground structures as directed by Engineer-in-Charge and consisting of : i) Ist layer of 22
mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1
cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended
proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with
cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3
coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone
aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.

15.1.1 Using rough kota stone.


1315 sqm
Rate
Item No. Description of Items Qty Unit
(In figures)
15.2 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified
stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645
in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces
and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of
stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with
water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-
charge :

15.2.1 Using rough Kota stone


590 sqm

15.3 Providing and laying integral cement based water proofing treatment including preparation of surface as required
for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat
cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and
approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including
cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to
115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5
(1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by
Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs

c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed
with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed
with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying
glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat
cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be
flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be
done in order and as directed and specified by the Engineer-in-Charge :

15.3.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
1400 sqm

15.4 Grading roof for water proofing treatment with


15.4.1 Cement mortar 1:3 (1 cement : 3 coarse sand)
29 cum
Rate
Item No. Description of Items Qty Unit
(In figures)

SubHead: RAIN WATER HARVESTING & TUBEWELLS

16.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part
I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire
& running charges of all equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, upto 90 metre depth below ground level.

16.1.1 All types of soil


16.1.1.1 400 mm dia
80 metre

16.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing
(CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings &
accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.

16.2.1 200 mm nominal size dia


80 metre

16.3 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required
thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 12 cum

16.4 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing
layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 8 cum

16.5 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required
thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 6 cum

16.6 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/
coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- 12 cum
charge.

16.7 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than
M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T.
hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding
with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1 each

SubHead: STRUCTURAL GLAZING AND ALUMINIUM COMPOSITE PANEL


Rate
Item No. Description of Items Qty Unit
(In figures)

17.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural
drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS
1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and
shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves,
20240 kg
screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this
account).

17.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural
glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels,
including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS
875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure),
including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium
cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather
silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water
tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required
sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and
fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using
stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc.
of stainless steel grade 316, of the required capacity and in required numbers.

c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant
compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop
environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand
and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.
d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and
profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces
with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight,
by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required),
making necessary holes of required sizes and of required numbers etc. complete.
Rate
Item No. Description of Items Qty Unit
(In figures)
This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid,
installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling
temporary structures and services, cranes or cradles etc. as described above and as specified. The item
includes the cost of getting all the structural and functional design including shop drawings checked by a
structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site,
cost of all samples of the individual components for testing in an approved laboratory, field tests on the
assembled working structural glazing as specified, cleaning and protection till the handing over of the building for
occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance
characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as
specified, as per the approved shop drawings and as directed by the Engineerin- Charge.

Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping
for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for
separately under relevant items under this subhead. However, for the purpose of payment, only the actual area
of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two
decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area
of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL (National
Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost
of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of
cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system
Tests to be conducted in the NBL Certified laboratories

1. Performance Laboratory Test for Air Leakage Test (-50pa to 300pa) & (+50pa to +300pa) as per ASTM E-
283-04 testing method for a range of testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000
ml.
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000
ml
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure
without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test Tests to be 1014 sqm
conducted on site
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml
Rate
Item No. Description of Items Qty Unit
(In figures)
17.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm
insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an
outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on
surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube
12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete
for the required performances, as per the Architectural drawings, as per the approved shop drawings, as
specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of
the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)
For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves 1014 sqm
and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm
Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to
35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and
U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical
sanctioning authority as per the site requirement.

17.4 Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all
accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty
stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc.
including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the
Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in- 254 sqm
Charge.

SCHEDULE OF QUANTITY (Internal Electrial Work)

SUB-HEAD - I (Wiring )

1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI
box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as
required

a) Group C
557 Pts.

2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in
surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 16 Pts.
Rate
Item No. Description of Items Qty Unit
(In figures)
3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for
loop earthing as required. 1000 Mtr.

4 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for
loop earthing as required. 500 Mtr.

5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel conduit as required

a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire


1000 Mtr.

b) 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire


600 Mtr.

c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire


100 Mtr.

d) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire


60 Mtr.

6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing
surface/ recessed steel / PVC conduit as required.

a) 3 x 1.5 sq. mm
250 Mtr.

b) 4 x 1.5 sq. mm
120 Mtr.

c) 5 x 1.5 sq. mm
120 Mtr.

d) 6 x 1.5 sq. mm
100 Mtr.
Rate
Item No. Description of Items Qty Unit
(In figures)
e) 3 x 4 sq. mm
1100 Mtr.

7 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting
in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
(For Telephone, Fire alarm, Point wiring & Emergency Lighting)

a) 20 mm
1550 Mtr.

b) 25 mm
1800 Mtr.

8 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored
telephone cable in the existing surface/ recessed steel/ PVC conduit as required.

a) 2 Pair
1600 Mtr.

9 Supplying and Laying of one number armoured jelly filled telephone cable confirming to last IFD specification NO
> G/CUG-01/02 of Feb 96 of conductor size 0.50 mm in the existing RCC/HUME/ STONEWARE/ METAL PIPE/
on surface etc. as reqd.

250 Mtr.
a) 50 Pair

10 Supplying, Installation, Testing and Commissioning of following size Krone Box with same number of pairs base
unit - chrome plated frame enclosed in krone box having locking arrangement i/c making connection, including
testing of cable etc. as reqd.

a) 50 Pairs
6 Each

11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including
connections but excluding modular plate etc. as required..

a) Telephone socket outlet


75 Each

b) Giga speed RJ 45 information outlet with shutter


100 Each
Rate
Item No. Description of Items Qty Unit
(In figures)

12 Supplying/ Fixing of suitable size of modular plates i/c providing & fixing following accessories i/c connection etc.
a) one way 16 A modular switchwith indicator -1 no.
b) 5/6 A modular 3 pin Shuttered Socket -3 no. 100 Each

13 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches
in recess etc as required.
a) 1 or 2 Module (75mmX75mm)
50 Each

14 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as
required. (For light plugs to be used in non residential buildings). 12 Each

15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection 116 Each
etc. as required.

16 Supplying and fixing 25 amp. Starter with 4 module GI box in recess and 1 no. 25 Amp 6 pin socket outlet i/c
connection etc as required. 8 Each

17 Supplying/ Fixing of suitable size of modular type metal box on surface/ recess with modular plates i/c providing
& fixing following accessories i/c connection etc. as required.(two module).

a) Buzzer 230 V a.c.- 1 No.


47 Each

18 Supplying and embedding of following sizes of under floor trunking made out of 1.6 mm thick Hot Dip
Galvanised Steel sheet having below mentioned compartments including Jointing sleeves, floor fixing supports,
chipping and levelling that portion of the floor etc in the floor / in recess etc as per specifications complete as
required.
a) 250 mm wide X 38 mm deep ( 3 Compartments )
50 Mtr.

a) 150 mm wide X 38 mm deep ( 2 Compartments )


250 Mtr.
Rate
Item No. Description of Items Qty Unit
(In figures)
19 Supplying and fixing of following sizes of under floor junction boxes made out of 1.6 mm thick pre-galvnaized
sheet steel, top cover with 2.5 mm thick pre-galvanized steel plate alongwith changeover fly-overs including
chipping and levelling that portion of the floor etc as per specifications complete as required.

a) 250 X 250 X 60 - 75 mm ( 3 compartment )


12 Each

b) 150 X 150 X 60 - 75 mm
28 Each

SUB-HEAD - II ( FITTINGS)

1 Supply,installation,testing & commissioning of rimless fixtures of following Diameter with round shaped housing
made ofwhite powder coated aluminium suitable for trimless installation into plasterboard ceilings 10 - 25 mm
offset satin PMMA cover for uniform illumination with T-16 LAMP/LED and 1 - 10V or DALI Ballast.Make:XAL
(INVISIBLE ROUND)/ARTIMIDE(VIABIZZUNO/ CAMPANA BREMBANA) or equivalent model of ZUMTOBEL

A DIA- 160 MM LAMP 18 W


2 Each

B DIA- 260 MM LAMP 22 W


2 Each

C DIA- 350 MM LAMP 40 W


2 Each

D DIA- 450 MM LAMP 60 W


2 Each

2 Supply, Installation & commissioning of 1200mm length in extruded aluminium housing and high efficiency opal
diffuser ceiling suspended up-down LED light fixture with system lumen output of 4400 lumens and efficacy
better than 80 lumen per watt rated life of 50K burning Hrs @L70, pf better than 0.9 and THD less then 20% and
CCT 5000k with Philips / Atco tridonic Dimmable ballast including wire suspension kit in Y-form and transparent
cable for suspension heights up to 1000 mm . Make Philips Startus or equivalent models of zumtobel/Trilux 55 Each
/XAL/ENDO
Rate
Item No. Description of Items Qty Unit
(In figures)
3 Supplying and fixing of decorative direct indirect circular luminaire , Reflector: anodized aluminum,Components:
polycarbonate. Glare should be controlled in all viewing directions. including providing 40/55/60 watt flourescent
lamp / LED and connection with transparent cable and integrated 3 point wire suspension fully adjustable for
suspension length of upto 3 metres Make:TRILUX:POLORON WD2 SUSPENDED/Zumtobel: ONDARIA/OMS 10 Each
:TUBUS VISION PENDENT

4 SITC of LED weatherproof IP 66 ,1200 mm fixture having system lumen output of 2000 lumens and efficacy
better than 90 lumen/ watt with opal diffuser IN POLYCARBONATE and life of 50K burning hours(L 70) including
fixing with conduit / pipe/ surface mounting and connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC
sheathed copper conductor cable in flexible GI conduit etc. as reqd.Make :TRILUX( ZALUX ALHAMA LED) 43 Each
/ZUMTOBEL(CHIARO II ) or equivalent model of LEDALITE/ENDO

5 Supply, Installation, testing and commissioning of LED Luminaire Consisting of extruded aluminium profiles, very
slender appearance white fine powder-coated with Pre-mounted 1-point wire suspension in Y-form and
transparent cable for suspension heights to 1500 mm. Direct/indirect distribution comprising of high power LEDs
integrated in separate high performance precision lenses. LED with constant colour stability and a colour
rendering index of Ra > 80 over the complete service life. Neutral white light colour, colour temperature 4000K,
total luminous flux 6300 lm, Luminous efficiency of luminaire better then 72 lm/W . Electronic power supply
integrated within luminaire. With digitally dimmable arrangement. L80 LED mortality B10, Service life 50000 3 Each
operating hours. Finely structured powder-coated. Colour white. Safety class I, MAKE: TRILUX Cat No NEXIMO
H2 LED 6300nw) or equivalent model of XAL/ZUMTOBEL

6 SITC of 300mm x 300 mm surface type(white colored)LED Luminaire with diecast aluminium construction having
system lumen output of 1600 Lumens and efficacy better than 80 Lumen/watt having cct 4000K and CRI >70 &
P.F better then 0.9.Make(Philips Cirrus Mini or equivalent models of zumtobel/Trilux/endo) 20 Each

7 Supplying, installation, testing and commissioning of flat LED panel (edgelit)of 595 x 595 mm size down light with
efficacy better than 75 Lumen/watt (minimum total lumen delivered package 3000 ), with diffuser and aluminium
framing , downward light 6500k with Philips / Atco tridonic Dimmable ballast including making suspansion
arrangement with gear wire including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed 35 Each
copper conductor cable in flexible GI conduit etc as required. Makes:- zumtobel/ Trilux /Philips/ ENDO
Rate
Item No. Description of Items Qty Unit
(In figures)
8 Supply, Installation, testing and commissioning of Ceiling suspended 1500 mm; "Tunable White" LED luminaire,
dynamic variation in colour temperature; symmetric wide-beam light distribution with maximum luminaire
efficiency and optimum photometric properties; colour-temperature variation: 3000-6000K (warm white neutral
white daylight white); 60 watt colour rendering: RA90; 50,000h service life at 70% luminous flux; includes
controllable ballast, dimmable Dali/DMX .The system comprises PMMA OPTIC 100 mm DIA OPAL cover,LED
MODULES and continuity modules.Intermodule mechanical connection by ACRYLIC Linear connectors for
cover, electrical connection via quick connectors, 2000 mm quick adjustment steel suspension cables, 3 X 1.5 12 Each
SQ MM transparent cable and other specific standards and all other necessary accessories.MAKE: XAL tubo
1500mm or equivalent models of ZUMTOBEL/ARTEMIDE)

9 Supplying, Installation, Testing & Commissioning of 1200 mm IP 65 LED Luminaire with Housing and cover made
of virgin polycarbonate with Color temperature 6500 K Suspended THD < 10% PF >0.95 having system lumen
output of 3500 Lumens with efficacy better than 80 lumen/ watt constant current electronic driver with CRI>80
and life of 50K burning hours(L 70) including fixing with conduit / pipe/ surface mounting and connection with 3 x
1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd. 9 Each
MAKE:ZUMTOBEL CHAIROII /PHILIPS ENDURA or equivalent model of ENDO

10 Supplying, Installation, Testing & Commissioning of highbay IP 65 integral LED luminaire with high pressure
diecast aluminium housing neutral white (4000 K) having system lumen output of 14000 lumens with efficacy
better than 100 lumen/ watt THD <20% PF >0.95,CRI >80 with inbuilt intelligence through DALI compatibility
and life of 50K burning hours(L-70) including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC
sheathed copper conductor cable . as reqd. (Make - Philips (Maxolid Highbay) or equivalent models of zumtobel 12 Each
or ENDO

11 Supplying, Installation, Testing & Commissioning of circular LED recess down lighter, neutral white of system
lumen output of 1500 Lumens with efficacy better than 65 lumen/ watt with high efficiency optics with high
reflective diffuser providing efficient glare free lighting and integral constant current electronic driver with CRI>70
and life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed 240 Each
copper conductor cable in flexible GI conduit etc. as reqd. (Make - Osram/ Philips/ Crompton/ ENDO/ Wipro)

12 Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable spot down lighter,
neutral white of system lumen output of 850 Lumens with efficacy better than 65 lumen/ watt with high efficiency
optics with high reflective diffuser providing efficient glare free lighting and integral constant current electronic
driver with CRI>70 and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC
insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd. (Make - TRILUX/ 40 Each
Philips/ ZUMTOBEL/ ENDO)
Rate
Item No. Description of Items Qty Unit
(In figures)

13 Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable spot down lighter,
neutral white of system lumen output of 850 Lumens with efficacy better than 65 lumen/ watt with high efficiency
optics with high reflective diffuser providing efficient glare free lighting and integral constant current electronic
driver with CRI>70 and dimmable ballast and expected life of 40K burning hours including connection with 3 x
1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd. 30 Each
(Make - TRILUX/ Philips/ ZUMTOBEL/ ENDO)

14 Supplying, Installation, Testing & Commissioning of circular LED recess down lighter, neutral white of system
lumen output of 1500 Lumens with efficacy better than 65 lumen/ watt with high efficiency optics with high
reflective diffuser providing efficient glare free lighting and integral constant current electronic driver with CRI>70
and dimmable ballast and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC
insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd. (Make - Osram/ 20 Each
Philips/ Crompton/ ENDO/ Wipro)

15 Supplying, Installation, Testing and Commissioning of 1200mm LED luminaire made of extruded aluminium
housing suitable for 240 Volt AC with system lumens output > 1100 and efficacy better than 75 lumens/watt
complete with integral electronic driver and life of 30000 burning hours or more etc. as reqd. (Make - Philips / 64 Each
Wipro / GE/ Osram)

16 Supply, Installation,testing& commissioning LED strip for cove 7 watt Per meter with 500 lumens output per
meter , CCT 3000k . Supply with driver suitable for 5 m led strip length 450 Mtr.
Make:TRILUX/ZUMTOBEL/PHILIPS/ENDO

17 Providing & Fixing mirror light with aluminium housing suitable for 14 watt T-5 lamp complete with lamp i/c
connection, earthing etc. as reqd (Philips Adreno or equivalentof Bajaj/Wipro/GE make). 12 Each

18 Supplying and fixing weather proof LED bulk head 10 watt fitting including connection, testing etc. as reqd. (Make
- Philips Endura or equivalent of Bajaj/Wipro/GE LED Bulkhead) 10 Each

19 Supplying, Installation, testing and commissioning of ceiling fan complete with all accessories of following sweep
including wiring the down rods of length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor,
single core cable etc. as required.(Make-Havells ES5/ Crompton Energy Smart/Usha Energia - ISI)

a) 1200mm sweep. 5-star rated


32 Each
Rate
Item No. Description of Items Qty Unit
(In figures)
SUB-HEAD - III (RISING MAIN & DISTRIBUTION BOARDS)

1 Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact
Type/Sandwich type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with enclosure made of
1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars,
necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous
earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle
iron bracket, steel fasteners, connecting to earthing system etc. as required

a) 200 amps 15KA SC for 1 sec


25 Mtr.

b) 400 amps 30KA SC for 1 sec


12 Mtr.

2 Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type bus trunking/ rising
mains, testing and commissioning of following capacity End Feed Unit for use on 3 phase 4 wire 415 volts, 50Hz
A.C. supply made with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB/ACB (but
without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel
fasteners, connecting to earthing system etc. as required

a) 200 amps 15KA SC for 1 sec


2 Each

b) 400 amps 30KA SC for 1 sec


1 Each

3 Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type bus trunking/ rising
mains, testing and commissioning of following capacity Plug In/ Tap Off Box for use on 3 phase 4 wire 415 volts,
50Hz A.C. supply with 1.6mm thick steel sheet enclosure duly powder coated with provision of MCCB (but
without MCCB) complete etc. as required

a) 125 amps 15KA SC for 1 sec


17 Each
Rate
Item No. Description of Items Qty Unit
(In figures)
4 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution
board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common
neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical
type MCB TPDB is normally used where 3 phase outlets are required.)

a) 4 way (4 + 12), Double door


10 Each

b) 8 way (4 + 24), Double door


7 Each

5 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for
inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning
etc. as required.
a) Single pole
288 Each

6 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board/MCB DB/tap off
boxes including making connections, etc. as required.

a) 63 Amp, 16 KA TP
34 Each

Sub Head IV (Compound Lighting)

1 Supplying, Installation, Testing and Commissioning of 3 Mtr. height MS decorative type steel tubular pole, duly
primed and painted. The pole shall be painted with MRF Poly urethane paint of approved colour. The bottom and
middle embelishment are cast in iron and upper ring are cast in aluminium, fixed to the column by grub screw.
The cloumn shall be provided with inbuilt loop box, earth stud with 4 way 25 Amp heavy duty connector, 1 Nos.
SP MCB and shall have matching flush door, fabricated & painted complete & making cement concrete
foundation of size 500mm x 500mm x 700mm depth complete with S/F 16mm dia 8 inch long hot dip glavanized
L-type Anchor bolts, plastering the same with fine sand and having horizontal top surface without any slope
including two coats of trump exterior paint complete as required.

The pole shall be divided in two sections:


a) Top - Dia 75mm. Length 2000mm (3.2mm thick)
b) Bottom - Dia 114mm. Length 1000mm (4.0mm thick)
c) Base plate - 250mm x 250mm x 10mm thick duly welded to cloumn
Rate
Item No. Description of Items Qty Unit
(In figures)
(Make-Twinkle-Classic Steel 114-302/or its equilalent model of KLITE/ Bajaj)
29 Each

2 Supplying, installation, testing and commissioning of 42 watt, warm white with integral driver, closed diffuser,
IP65 protection, stylish, robost, Decorative Post Top Lantern fitting (total delivered lumen 2100) suitable to work
on 220-240 volt AC Supply, with vertical mounting on existing 75 mm dia poles including connections with 3 core
X 1.5 sq mm PVC insulated PVC sheathed copper conductor round cablefrom looping box to posttop lantern etc.
as reqd etc. as reqd. (Make- Philips BGP 150 LED2000/NW PSU 220-240V 7043or equivalent models of 29 Each
ZUMTOBEL/HADCO/XAL)

3 Supplying, Installation, Testing & Commissioning of 8 watt LED bollard fitting with warm white light integral type
driver, close diffuser and cast aluminium IP-65 housing 220-240V AC supply on suitable CC foundation (1:1.5:3)
complete as required. (Make- Philips BCP 151 LED 150/WW PSU 220-240V 7043 or equivalent model of 85 Each
Hadco/zumtobel/ENDO)

4 Suppplying & Laying of following XLPE insulated and PVC sheathed aluminium conductor armoured power cable
of 1.1 KV grade of following size in the existing DWC / GI pipe complete as required.

a) 2 x 6 sq mm
450 Mtr.

b) 2 x 10 sq mm
500 Mtr.

5 Supplying & Laying of following XLPE insulated and PVC sheathed aluminium conductor armoured power cable
of 1.1 KV grade of following size on surface as required.

a) 2 x 6 sq mm
75 Mtr.

b) 2 x 10 sq mm
80 Mtr.

6 Supplying and Laying of following sizes of DWC corrugated pipe with coupling socket direct in ground i/c
excavation in ground i/c refilling the trench for passage of cable through it etc. as reqd.
Rate
Item No. Description of Items Qty Unit
(In figures)
a) 78/63mm dia (OD/ID)
750 Mtr.

7 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for
cable entry including bending the pipe to the required shape complete as required.

a) 40 mm dia
88 Mtr.

8 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure
with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
2 Set

9 Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15 mm dia GI pipe from
earth electrode including connection with GI thimble, excavation and refilling etc as required. 10 Mtr.

10 Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing etc. as required.
10 Mtr.

11 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/
recessed conduit/ submain wiring/ cable as required. 1100 Mtr.

SUB-HEAD - V (EARTHING)

1 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/
coke and salt as required. (4 Nos. for Rising Main & 4 Nos. for Lightning Conductor) 8 Set

2 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection
with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 30 Mtr.

3 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
20 Mtr.
Rate
Item No. Description of Items Qty Unit
(In figures)
4 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/
coke and salt as required. (For UPS Rising Main) 2 Set

5 Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I.pipe from earth electrode etc as per
specifications complete as required. 15 Mtr.

6 Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc as per specifications
complete as required. 10 Mtr.

SUB-HEAD - VI (LIGHTNING CONDUCTOR)

1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong
at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 4 Each

2 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by
riveting / nut bolting/ sweating and soldering etc as required. 30 Each

3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete
as required.(For horizontal run) 130 Mtr.

4 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete
as required.(For vertical run) 60 Mtr.

5 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts,
nuts, chuck nuts and spring washers etc. complete as required. 4 Each

6 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
40 Mtr.

Sub Head VII ( Cables)

1 Supplying and fixing following sizes of Steel Wire cable trays electro zinc type including couplers, fittings and
other accessories as required, and duly suspended from the ceiling with suspenders/fixed on ceiling/walls on
fastners etc as per specifications complete as required.Make cablofil/ obo betterman
Rate
Item No. Description of Items Qty Unit
(In figures)
a) 300 mm width X 50 mm depth
200 Mtr

b) 150 mm width X 50 mm depth


250 Mtr

2 Supplying and laying of following sizes of XLPE insulated & PVC sheathed glavanised steel strip/wire armoured
copper conductor cable of 1.1 KV grade on surface / cable tray / recess etc as per specifications complete as
required.
a) 3 x 4 sq.mm.
400 Mtr

b) 4 X 6 sq mm
250 Mtr

c) 4 X 10 sq mm
200 Mtr

3 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC
insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

a) 3 x 4 sq.mm.
10 Each

b) 4 X 6 sq. mm
8 Each

c) 4 X 10 sq. mm (25mm)
6 Each

Sub Head VIII ( Emergency Lighting System, Exit Signage & Networking)

1 Supplying & Fixing emergency lighting control panel with two lighting lines with minimum of 127 devices on each
line. The system shall work on extra low voltage and shall be addressable 1 Each

2 Supplying and Fixing ELS Panel transformer 230V with an output of 35V ac and capable of providing low voltage
supply to the lighting lines. 1 Each
Rate
Item No. Description of Items Qty Unit
(In figures)
3 Supplying and Fixing of Key pad with an LCD to control and read the Main ELS Control Panel
1 Each

4 Supplying and Fixing of Addressable Open Area LED Down Lighting compling with BS5266 with integral battery
capacity of 2 hrs. and bicoloured LED status indicator 20 Each

5 Supplying and Fixing Addressable exit signage visible from 20 mtrs. with integral battery capacity of 2 hrs. and
bicoloured LED status indicator 40 Each

6 Supplying & drawing Giga speed UTP 4 pair CAT-6 type computer data cable in the existing surface/recessed
PVC/steel conduit/ floor trunking/cable tray etc as per specifications complete as required.

a) 1 x 4 pair
1600 mtr

7 Supplying, Installation, testing and commissioning of Giga Speed 24 Port Patch max Giga Speed Jack Panel
including making end termination and connections of data cable complete as required. 4 Set

8 Supplying, Installation, testing and commissioning of dust and moisture proof 6U Cabinet for the patch panel .
2 Set

9 Supplying and fixing 100mm X 50 mm DLP, UPVC cable management trunking on surface with 82 mm cover,
Tee, Internal & External angle, Flate angle cable retainer, internal coupler, flat cross, end cap and joint cover etc 250 mtr
as required.

Sub Head IX Lighting Control System

1 SITC of following components of lighting control system of distributed intelligence type comprising of input and
output control modules featuring an embedded microprocessor and non-volatile memory comprising of
occupancy sensors, keypads, light level sensors, motion sensors, touch screens, modular relays, modular
dimmers, modular input units and modular networking devices as per the enclosed specifications. Make:Given
models of Dynalite or equivalent models of Lutron/Zummtobel

a) SITC of Multi controller with 8 channel module having 4 channel relay module and 4 channel dimmer module
(dynalite DDMC802 or equivalent model of lutron/Zumtobel) 4 Each/set
Rate
Item No. Description of Items Qty Unit
(In figures)
b) SITC of 8 channel trailing edge dimmer each of 2amp (dynalite DDTE802 or equivalent model of
lutron/Zumtobel) 4 Each/set

c) SITC of 8 channel 10 amp relay module with din rail mounting arrangement ( dynalite DDRC810 or equivalent
model of lutron/Zumtobel) 4 Each

d) SITC of programmable capacitive touch switch with different surface finishes and graphic (dynalite Antumbra or
equivalent model of lutron/Zumtobel) 18 Each

e) Supplying, installation, testing and commissioning of false ceiling mounted PIR type occupancy sensor for a
coverage of 45 sq mtr and diametric range of 8 mtr with setting of 0 sec to 600 sec time delay and suitable for
1000 VA fluroscent light load/500 watt /LED Load including wiring with 1.5 sq.mm. FR-LSH PVC insulated
650/1100 V grade multistranded copper conductor cable complete etc as required. (Make:DYNALITE/ 25 Each
LUTRON/Zumtobel/PHILIPS)

f) IR Remote Control. (Make:DYNALITE/ LUTRON/ZEMTOBEL)


4 Each

g) Supply & fixing of Daylight , IR and occupancy sensor network base with lux setting from 300 lux to 800 lux
( dynalite DDRC810 or equivalent model of lutron/Zumtobel)
22 Each

h) Software & Hardware required for running of the entire lighting control system of each floor(DESKTOP to be
PROVIDED BY CLIENT)(dynalite cosoft or equivalent model of lutron/ZUMTOBEL)
1 Job

i) SITC of AV controller for board room with 4 IR to IP conversion compatibility including providing Ipad ( use as
touch screen ) with desired apps to control complete board room automation and control as desired by client
(Make: global catch /lutron/DYNALITE/IPAD/ ZUMTOBEL/ Creston/Control Four) 2 Each

Sub Head X WATER INGRESS DETECTION

1 SITC of Water Leak Sensing Cable/Tape as per specifications


70 Mtr.

2 SITC of Electronic Sounder 85db as per specifications


1 Each
Rate
Item No. Description of Items Qty Unit
(In figures)

3 of SITC 4 Zone Water Leak Conventional Panel with Battery Charger & Battery as per specification
1 Each

Sub Head XI RODENT REPELLANT SYSTEM

1 Supply, installation, testing and commissioning of Rodent repellant sysytem consisting of VHFO Console along
with the indicators incuding termination of the cable 2 Each

2 Supply and fixing of satellites above false ceiling, below ceiling and below false flooring.
40 Each

3 MS Stand for fixing the master console unit.


2 Each

SCHEDULE OF QUANTITY (2 Nos. Passenger Lifts)

1 Supplying, Installation, Testing & Commissioning of 13 passengers (884 Kgs.), gearless passenger lift having
contract speed of 1.0 MPS serving different floors in the lift shaft and barrier free requirements as per Appendix-
VII of CPWD General Specifications for Electrical Works (Part-III-Lifts & Escalators), 2003 and as per detailed
specifications enclosed and as under: -

Location of lifts :- In the proposed Annexxe Building for NABARD at Sector 34, Chandigarh.

i) Speed - 1.0 MPS (Minimum).


ii) Floors to be served - 4 (Basement, Ground + 2)
iii) Travel - 10.75 Meters (approx.)
iv) Stops & Opening - Four (B,G+2) on same side
v) Controller - AC VariableVoltageVariable Frequency.
vi) Automatic rescue device complete with dry maintenance free batteries as required.
vii) Operation - Microprocessor based, simplex selective collective with/without attendent.

viii) Power - 415 V, 3 Phase, 50 Hz, AC.


ix) Type of doors
a) Car Entrance - Power operated centre opening horizontal sliding Stainless steel mirror etched finish with
multi beam infrared/ultra sonic door detector.
b) Landing doors - Stainless steel etched finish.
x) A stainless steel hand rail in mirror finish at 900 mm above floor level to be fixed on three side of car.
Rate
Item No. Description of Items Qty Unit
(In figures)
xi) Voice announcement system in the car to announce the position of the elevator in the hosit way as the car
passes or stops at a floor served by the elevator.

xiii) complete with all respect including providing & fixing guide rails, minor building works, scaffolding, putting into
operation & final testing etc. as reqd.
2 each

Total
SCHEDULE OF QUANTITIES
garh including Internal Water Supply, Sanitary Installations Drainage and Internal Electrical Installations, SITC of 2 Nos.

Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00

#VALUE! 0.00
Rate Amount
(In words) (In figures)

#VALUE! 0.00

0.00
SCHEDULE OF QUANTITY (Internal Electrial Work)

SUB-HEAD - I (Wiring )

1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in surface / recessed steel conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS PVC insulated copper conductor single core cable etc as required

a) Group C
2 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable in surface / recessed steel conduit, 2 way modular switch, modular
plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper
conductor single core cable etc as required.

3 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor
single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC
insulated copper conductor single core cable for loop earthing as required.

4 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor
single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS
PVC insulated copper conductor single core cable for loop earthing as required.

5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as
required

a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire


b) 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
d) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire

6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single
core cable in the existing surface/ recessed steel / PVC conduit as required.

a) 3 x 1.5 sq. mm
b) 4 x 1.5 sq. mm
c) 5 x 1.5 sq. mm
d) 6 x 1.5 sq. mm
e) 3 x 4 sq. mm

7 Supplying and fixing of following sizes of steel conduit along with accessories in
surface/recess including painting in case of surface conduit, or cutting the wall and
making good the same in case of recessed conduit as required. (For Telephone, Fire
alarm, Point wiring & Emergency Lighting)
a) 20 mm
b) 25 mm

8 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper
conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC
conduit as required.
a) 2 Pair

9 Supplying and Laying of one number armoured jelly filled telephone cable confirming to
last IFD specification NO > G/CUG-01/02 of Feb 96 of conductor size 0.50 mm in the
existing RCC/HUME/ STONEWARE/ METAL PIPE/ on surface etc. as reqd.

a) 50 Pair

10 Supplying, Installation, Testing and Commissioning of following size Krone Box with
same number of pairs base unit - chrome plated frame enclosed in krone box having
locking arrangement i/c making connection, including testing of cable etc. as reqd.

a) 50 Pairs

11 Supplying and fixing following modular switch/ socket on the existing modular plate &
switch box including connections but excluding modular plate etc. as required..

a) Telephone socket outlet


b) Giga speed RJ 45 information outlet with shutter

12 Supplying/ Fixing of suitable size of modular plates i/c providing & fixing following
accessories i/c connection etc. a)
one way 16 A modular switchwith indicator -1 no. b) 5/6 A modular 3 pin Shuttered
Socket -3 no.

13 Supplying and fixing following size/ modules, GI box alongwith modular base & cover
plate for modular switches in recess etc as required.

a) 1 or 2 Module (75mmX75mm)

14 Supplying and fixing suitable size GI box with modular plate and cover in front on surface
or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6
amps modular switch, connection etc. as required. (For light plugs to be used in non
residential buildings).

15 Supplying and fixing suitable size GI box with modular plate and cover in front on surface
or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet
and 15/16 amps modular switch, connection etc. as required.
16 Supplying and fixing 25 amp. Starter with 4 module GI box in recess and 1 no. 25 Amp 6
pin socket outlet i/c connection etc as required.

17 Supplying/ Fixing of suitable size of modular type metal box on surface/ recess with
modular plates i/c providing & fixing following accessories i/c connection etc. as required.
(two module).
a) Buzzer 230 V a.c.- 1 No.

18 Supplying and embedding of following sizes of under floor trunking made out of 1.6 mm
thick Hot Dip Galvanised Steel sheet having below mentioned compartments including
Jointing sleeves, floor fixing supports, chipping and levelling that portion of the floor etc
in the floor / in recess etc as per specifications complete as required.

a) 250 mm wide X 38 mm deep ( 3 Compartments )


b) 150 mm wide X 38 mm deep ( 2 Compartments )

19 Supplying and fixing of following sizes of under floor junction boxes made out of 1.6 mm
thick pre-galvnaized sheet steel, top cover with 2.5 mm thick pre-galvanized steel plate
alongwith changeover fly-overs including chipping and levelling that portion of the floor
etc as per specifications complete as required.

a) 250 X 250 X 60 - 75 mm ( 3 compartment )


b) 150 X 150 X 60 - 75 mm

SUB-HEAD - II ( FITTINGS)

1 Supply,installation,testing & commissioning of rimless fixtures of following Diameter with


round shaped housing made ofwhite powder coated aluminium suitable for trimless
installation into plasterboard ceilings 10 - 25 mm offset satin PMMA cover for uniform
illumination with T-16 LAMP/LED and 1 - 10V or DALI Ballast.Make:XAL (INVISIBLE
ROUND)/ARTIMIDE(VIABIZZUNO/ CAMPANA BREMBANA) or equivalent model of
ZUMTOBEL

A DIA- 160 MM LAMP 18 W


B DIA- 260 MM LAMP 22 W
C DIA- 350 MM LAMP 40 W
D DIA- 450 MM LAMP 60 W

2 Supply, Installation & commissioning of 1200mm length in extruded aluminium housing


and high efficiency opal diffuser ceiling suspended up-down LED light fixture with system
lumen output of 4400 lumens and efficacy better than 80 lumen per watt rated life of 50K
burning Hrs @L70, pf better than 0.9 and THD less then 20% and CCT 5000k with
Philips / Atco tridonic Dimmable ballast including wire suspension kit in Y-form and
transparent cable for suspension heights up to 1000 mm . Make Philips Startus or
equivalent models of zumtobel/Trilux /XAL/ENDO
3 Supplying and fixing of decorative direct indirect circular luminaire , Reflector: anodized
aluminum,Components: polycarbonate. Glare should be controlled in all viewing
directions. including providing 40/55/60 watt flourescent lamp / LED and connection
with transparent cable and integrated 3 point wire suspension fully adjustable for
suspension length of upto 3 metres Make:TRILUX:POLORON WD2
SUSPENDED/Zumtobel: ONDARIA/OMS :TUBUS VISION PENDENT

4 SITC of LED weatherproof IP 66 ,1200 mm fixture having system lumen output of 2000
lumens and efficacy better than 90 lumen/ watt with opal diffuser IN POLYCARBONATE
and life of 50K burning hours(L 70) including fixing with conduit / pipe/ surface mounting
and connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper
conductor cable in flexible GI conduit etc. as reqd.Make :TRILUX( ZALUX ALHAMA LED)
/ZUMTOBEL(CHIARO II ) or equivalent model of LEDALITE/ENDO

5 Supply, Installation, testing and commissioning of LED Luminaire Consisting of extruded


aluminium profiles, very slender appearance white fine powder-coated with Pre-mounted
1-point wire suspension in Y-form and transparent cable for suspension heights to 1500
mm. Direct/indirect distribution comprising of high power LEDs integrated in separate
high performance precision lenses. LED with constant colour stability and a colour
rendering index of Ra > 80 over the complete service life. Neutral white light colour,
colour temperature 4000K, total luminous flux 6300 lm, Luminous efficiency of luminaire
better then 72 lm/W . Electronic power supply integrated within luminaire. With digitally
dimmable arrangement. L80 LED mortality B10, Service life 50000 operating hours.
Finely structured powder-coated. Colour white. Safety class I, MAKE: TRILUX Cat No
NEXIMO H2 LED 6300nw) or equivalent model of XAL/ZUMTOBEL

6 SITC of 300mm x 300 mm surface type(white colored)LED Luminaire with diecast


aluminium construction having system lumen output of 1600 Lumens and efficacy better
than 80 Lumen/watt having cct 4000K and CRI >70 & P.F better then 0.9.Make(Philips
Cirrus Mini or equivalent models of zumtobel/Trilux/endo)

7 Supplying, installation, testing and commissioning of flat LED panel (edgelit)of 595 x 595
mm size down light with efficacy better than 75 Lumen/watt (minimum total lumen
delivered package 3000 ), with diffuser and aluminium framing , downward light 6500k
with Philips / Atco tridonic Dimmable ballast including making suspansion arrangement
with gear wire including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC
sheathed copper conductor cable in flexible GI conduit etc as required. Makes:-
zumtobel/ Trilux /Philips/ ENDO
8 Supply, Installation, testing and commissioning of Ceiling suspended 1500 mm;
"Tunable White" LED luminaire, dynamic variation in colour temperature; symmetric
wide-beam light distribution with maximum luminaire efficiency and optimum photometric
properties; colour-temperature variation: 3000-6000K (warm white neutral white
daylight white); 60 watt colour rendering: RA90; 50,000h service life at 70% luminous
flux; includes controllable ballast, dimmable Dali/DMX .The system comprises PMMA
OPTIC 100 mm DIA OPAL cover,LED MODULES and continuity modules.Intermodule
mechanical connection by ACRYLIC Linear connectors for cover, electrical connection
via quick connectors, 2000 mm quick adjustment steel suspension cables, 3 X 1.5 SQ
MM transparent cable and other specific standards and all other necessary
accessories.MAKE: XAL tubo 1500mm or equivalent models of ZUMTOBEL/ARTEMIDE)

9 Supplying, Installation, Testing & Commissioning of 1200 mm IP 65 LED Luminaire with


Housing and cover made of virgin polycarbonate with Color temperature 6500 K
Suspended THD < 10% PF >0.95 having system lumen output of 3500 Lumens with
efficacy better than 80 lumen/ watt constant current electronic driver with CRI>80 and life
of 50K burning hours(L 70) including fixing with conduit / pipe/ surface mounting and
connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor
cable in flexible GI conduit etc. as reqd. MAKE:ZUMTOBEL CHAIROII /PHILIPS
ENDURA or equivalent model of ENDO

10 Supplying, Installation, Testing & Commissioning of highbay IP 65 integral LED


luminaire with high pressure diecast aluminium housing neutral white (4000 K) having
system lumen output of 14000 lumens with efficacy better than 100 lumen/ watt THD
<20% PF >0.95,CRI >80 with inbuilt intelligence through DALI compatibility and life of
50K burning hours(L-70) including connection with 3 x 1.5 sq.mm. PVC insulated FRLS
PVC sheathed copper conductor cable . as reqd. (Make - Philips (Maxolid Highbay) or
equivalent models of zumtobel or ENDO

11 Supplying, Installation, Testing & Commissioning of circular LED recess down lighter,
neutral white of system lumen output of 1500 Lumens with efficacy better than 65 lumen/
watt with high efficiency optics with high reflective diffuser providing efficient glare free
lighting and integral constant current electronic driver with CRI>70 and life of 40K
burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC
sheathed copper conductor cable in flexible GI conduit etc. as reqd. (Make - Osram/
Philips/ Crompton/ ENDO/ Wipro)
12 Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable
spot down lighter, neutral white of system lumen output of 850 Lumens with efficacy
better than 65 lumen/ watt with high efficiency optics with high reflective diffuser
providing efficient glare free lighting and integral constant current electronic driver with
CRI>70 and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm.
PVC insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as
reqd. (Make - TRILUX/ Philips/ ZUMTOBEL/ ENDO)

13 Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable


spot down lighter, neutral white of system lumen output of 850 Lumens with efficacy
better than 65 lumen/ watt with high efficiency optics with high reflective diffuser
providing efficient glare free lighting and integral constant current electronic driver with
CRI>70 and dimmable ballast and expected life of 40K burning hours including
connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor
cable in flexible GI conduit etc. as reqd. (Make - TRILUX/ Philips/ ZUMTOBEL/
ENDO)

14 Supplying, Installation, Testing & Commissioning of circular LED recess down lighter,
neutral white of system lumen output of 1500 Lumens with efficacy better than 65 lumen/
watt with high efficiency optics with high reflective diffuser providing efficient glare free
lighting and integral constant current electronic driver with CRI>70 and dimmable ballast
and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC
insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd.
(Make - Osram/ Philips/ Crompton/ ENDO/ Wipro)

15 Supplying, Installation, Testing and Commissioning of 1200mm LED luminaire made of


extruded aluminium housing suitable for 240 Volt AC with system lumens output > 1100
and efficacy better than 75 lumens/watt complete with integral electronic driver and life of
30000 burning hours or more etc. as reqd. (Make - Philips / Wipro / GE/ Osram)

16 Supply, Installation,testing& commissioning LED strip for cove 7 watt Per meter with 500
lumens output per meter , CCT 3000k . Supply with driver suitable for 5 m led strip
length Make:TRILUX/ZUMTOBEL/PHILIPS/ENDO

17 Providing & Fixing mirror light with aluminium housing suitable for 14 watt T-5 lamp
complete with lamp i/c connection, earthing etc. as reqd (Philips Adreno or equivalentof
Bajaj/Wipro/GE make).

18 Supplying and fixing weather proof LED bulk head 10 watt fitting including connection,
testing etc. as reqd. (Make - Philips Endura or equivalent of Bajaj/Wipro/GE LED
Bulkhead)
19 Supplying, Installation, testing and commissioning of ceiling fan complete with all
accessories of following sweep including wiring the down rods of length (upto 30 cm) with
1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
(Make-Havells ES5/ Crompton Energy Smart/Usha Energia - ISI)

a) 1200mm sweep. 5-star rated

SUB-HEAD - III (RISING MAIN & DISTRIBUTION BOARDS)

1 Supplying, installing on wall, testing and commissioning of following capacity Air


Insulated Compact Type/Sandwich type Rising Mains for use on 3 phase 4 wire 415
volts, 50Hz A.C. supply with enclosure made of 1.6mm thick steel sheet duly powder
coated in convenient sections complete with 4 Nos aluminium bus bars, necessary joints
& expansion joints, fire barrier at each floor, provision of tapping at every metre,
continuous earthing with 2 Nos aluminium strip of suitable size (one on each side)
including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to
earthing system etc. as required

a) 200 amps 15KA SC for 1 sec


b) 400 amps 30KA SC for 1 sec

2 Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type


bus trunking/ rising mains, testing and commissioning of following capacity End Feed
Unit for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel
sheet enclosure duly powder coated with provision of MCCB/ACB (but without
MCCB/ACB) complete with necessary joints including clamping brackets, angle iron
bracket, steel fasteners, connecting to earthing system etc. as required

a) 200 amps 15KA SC for 1 sec


b) 400 amps 30KA SC for 1 sec

3 Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type


bus trunking/ rising mains, testing and commissioning of following capacity Plug In/ Tap
Off Box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with 1.6mm thick steel
sheet enclosure duly powder coated with provision of MCCB (but without MCCB)
complete etc. as required

a) 125 amps 15KA SC for 1 sec

4 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts,
TPN MCB distribution board of sheet steel, dust protected, duly powder painted,
inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type
MCB TPDB is normally used where 3 phase outlets are required.)

a) 4 way (4 + 12), Double door


b) 8 way (4 + 24), Double door

5 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit
breaker suitable for inductive load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as required.

a) Single pole

6 Providing and fixing following rating and breaking capacity MCCB in existing cubicle
panel board/MCB DB/tap off boxes including making connections, etc. as required.

a) 63 Amp, 16 KA TP

Sub Head IV (Compound Lighting)

1 Supplying, Installation, Testing and Commissioning of 3 Mtr. height MS decorative type


steel tubular pole, duly primed and painted. The pole shall be painted with MRF Poly
urethane paint of approved colour. The bottom and middle embelishment are cast in iron
and upper ring are cast in aluminium, fixed to the column by grub screw. The cloumn
shall be provided with inbuilt loop box, earth stud with 4 way 25 Amp heavy duty
connector, 1 Nos. SP MCB and shall have matching flush door, fabricated & painted
complete & making cement concrete foundation of size 500mm x 500mm x 700mm
depth complete with S/F 16mm dia 8 inch long hot dip glavanized L-type Anchor bolts,
plastering the same with fine sand and having horizontal top surface without any slope
including two coats of trump exterior paint complete as required.

The pole shall be divided in two sections:


a) Top - Dia 75mm. Length 2000mm (3.2mm thick)
b) Bottom - Dia 114mm. Length 1000mm (4.0mm thick)
c) Base plate - 250mm x 250mm x 10mm thick duly welded to cloumn

(Make-Twinkle-Classic Steel 114-302/or its equilalent model of KLITE/ Bajaj)

2 Supplying, installation, testing and commissioning of 42 watt, warm white with integral
driver, closed diffuser, IP65 protection, stylish, robost, Decorative Post Top Lantern fitting
(total delivered lumen 2100) suitable to work on 220-240 volt AC Supply, with vertical
mounting on existing 75 mm dia poles including connections with 3 core X 1.5 sq mm
PVC insulated PVC sheathed copper conductor round cablefrom looping box to posttop
lantern etc. as reqd etc. as reqd. (Make- Philips BGP 150 LED2000/NW PSU 220-240V
7043or equivalent models of ZUMTOBEL/HADCO/XAL)
3 Supplying, Installation, Testing & Commissioning of 8 watt LED bollard fitting with warm
white light integral type driver, close diffuser and cast aluminium IP-65 housing 220-240V
AC supply on suitable CC foundation (1:1.5:3) complete as required. (Make- Philips BCP
151 LED 150/WW PSU 220-240V 7043 or equivalent model of Hadco/zumtobel/ENDO)

4 Suppplying & Laying of following XLPE insulated and PVC sheathed aluminium
conductor armoured power cable of 1.1 KV grade of following size in the existing DWC /
GI pipe complete as required.

a) 2 x 6 sq mm
b) 2 x 10 sq mm

5 Supplying & Laying of following XLPE insulated and PVC sheathed aluminium conductor
armoured power cable of 1.1 KV grade of following size on surface as required.

a) 2 x 6 sq mm
b) 2 x 10 sq mm

6 Supplying and Laying of following sizes of DWC corrugated pipe with coupling socket
direct in ground i/c excavation in ground i/c refilling the trench for passage of cable
through it etc. as reqd.
a) 78/63mm dia (OD/ID)

7 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/
foundation (during casting) for cable entry including bending the pipe to the required
shape complete as required.
a) 40 mm dia

8 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering
pipe etc. with charcoal/ coke and salt as required.

9 Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15
mm dia GI pipe from earth electrode including connection with GI thimble, excavation
and refilling etc as required.

10 Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing etc. as
required.

11 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along
with existing surface/ recessed conduit/ submain wiring/ cable as required.

SUB-HEAD - V (EARTHING)
1 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,
and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (4 Nos. for
Rising Main & 4 Nos. for Lightning Conductor)

2 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode
including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as
required.
3 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc.
as required.
4 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories,
and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (For UPS
Rising Main)

5 Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I.pipe from earth electrode
etc as per specifications complete as required.

6 Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections
etc as per specifications complete as required.

SUB-HEAD - VI (LIGHTNING CONDUCTOR)

1 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I.
tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including
holes etc. complete as required.

2 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other
metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

3 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For horizontal run)

4 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for
lightning conductor complete as required.(For vertical run)

5 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long,
with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

6 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as
required.

Sub Head VII ( Cables)


1 Supplying and fixing following sizes of Steel Wire cable trays electro zinc type including
couplers, fittings and other accessories as required, and duly suspended from the ceiling
with suspenders/fixed on ceiling/walls on fastners etc as per specifications complete as
required.Make cablofil/ obo betterman

a) 300 mm width X 50 mm depth


b) 150 mm width X 50 mm depth

2 Supplying and laying of following sizes of XLPE insulated & PVC sheathed glavanised
steel strip/wire armoured copper conductor cable of 1.1 KV grade on surface / cable tray
/ recess etc as per specifications complete as required.

a) 3 x 4 sq.mm.
b) 4 X 6 sq mm
c) 4 X 10 sq mm
3 Supplying and making end termination with brass compression gland and copper lugs for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of
1.1 KV grade as required.

a) 3 x 4 sq.mm.
b) 4 X 6 sq. mm
c) 4 X 10 sq. mm (25mm)

Sub Head VIII ( Emergency Lighting System, Exit Signage & Networking)

1 Supplying & Fixing emergency lighting control panel with two lighting lines with minimum
of 127 devices on each line. The system shall work on extra low voltage and shall be
addressable

2 Supplying and Fixing ELS Panel transformer 230V with an output of 35V ac and capable
of providing low voltage supply to the lighting lines.

3 Supplying and Fixing of Key pad with an LCD to control and read the Main ELS Control
Panel

4 Supplying and Fixing of Addressable Open Area LED Down Lighting compling with
BS5266 with integral battery capacity of 2 hrs. and bicoloured LED status indicator

5 Supplying and Fixing Addressable exit signage visible from 20 mtrs. with integral battery
capacity of 2 hrs. and bicoloured LED status indicator

6 Supplying & drawing Giga speed UTP 4 pair CAT-6 type computer data cable in the
existing surface/recessed PVC/steel conduit/ floor trunking/cable tray etc as per
specifications complete as required.

a) 1 x 4 pair
7 Supplying, Installation, testing and commissioning of Giga Speed 24 Port Patch max
Giga Speed Jack Panel including making end termination and connections of data cable
complete as required.

8 Supplying, Installation, testing and commissioning of dust and moisture proof 6U


Cabinet for the patch panel .

9 Supplying and fixing 100mm X 50 mm DLP, UPVC cable management trunking on


surface with 82 mm cover, Tee, Internal & External angle, Flate angle cable retainer,
internal coupler, flat cross, end cap and joint cover etc as required.

Sub Head IX Lighting Control System

1 SITC of following components of lighting control system of distributed intelligence type


comprising of input and output control modules featuring an embedded microprocessor
and non-volatile memory comprising of occupancy sensors, keypads, light level sensors,
motion sensors, touch screens, modular relays, modular dimmers, modular input units
and modular networking devices as per the enclosed specifications. Make:Given models
of Dynalite or equivalent models of Lutron/Zummtobel

a) SITC of Multi controller with 8 channel module having 4 channel relay module and 4
channel dimmer module (dynalite DDMC802 or equivalent model of lutron/Zumtobel)

b) SITC of 8 channel trailing edge dimmer each of 2amp (dynalite DDTE802 or equivalent
model of lutron/Zumtobel)
c) SITC of 8 channel 10 amp relay module with din rail mounting arrangement ( dynalite
DDRC810 or equivalent model of lutron/Zumtobel)

d) SITC of programmable capacitive touch switch with different surface finishes and
graphic (dynalite Antumbra or equivalent model of lutron/Zumtobel)

e) Supplying, installation, testing and commissioning of false ceiling mounted PIR type
occupancy sensor for a coverage of 45 sq mtr and diametric range of 8 mtr with setting
of 0 sec to 600 sec time delay and suitable for 1000 VA fluroscent light load/500 watt
/LED Load including wiring with 1.5 sq.mm. FR-LSH PVC insulated 650/1100 V grade
multistranded copper conductor cable complete etc as required. (Make:DYNALITE/
LUTRON/Zumtobel/PHILIPS)

f) IR Remote Control. (Make:DYNALITE/ LUTRON/ZEMTOBEL)


g) Supply & fixing of Daylight , IR and occupancy sensor network base with lux setting
from 300 lux to 800 lux ( dynalite DDRC810 or equivalent model of lutron/Zumtobel)

h) Software & Hardware required for running of the entire lighting control system of each
floor(DESKTOP to be PROVIDED BY CLIENT)(dynalite cosoft or equivalent model of
lutron/ZUMTOBEL)
i) SITC of AV controller for board room with 4 IR to IP conversion compatibility including
providing Ipad ( use as touch screen ) with desired apps to control complete board room
automation and control as desired by client (Make: global catch /lutron/DYNALITE/IPAD/
ZUMTOBEL/ Creston/Control Four)

Sub Head X WATER INGRESS DETECTION

1 SITC of Water Leak Sensing Cable/Tape as per specifications

2 SITC of Electronic Sounder 85db as per specifications

3 of SITC 4 Zone Water Leak Conventional Panel with Battery Charger & Battery as per
specification

Sub Head XI RODENT REPELLANT SYSTEM

1 Supply, installation, testing and commissioning of Rodent repellant sysytem consisting of


VHFO Console along with the indicators incuding termination of the cable

2 Supply and fixing of satellites above false ceiling, below ceiling and below false flooring.

3 MS Stand for fixing the master console unit.


557 Pts.

16 Pts.

1000 Mtr.

500 Mtr.

1000 Mtr.
600 Mtr.
100 Mtr.
60 Mtr.

250 Mtr.
120 Mtr.
120 Mtr.
100 Mtr.
1100 Mtr.
1550 Mtr.
1800 Mtr.

1600 Mtr.

250 Mtr.

6 Each

75 Each
100 Each

100 Each

50 Each

12 Each

116 Each
8 Each

47 Each

50 Mtr.
250 Mtr.

12 Each
28 Each

2 Each
2 Each
2 Each
2 Each

55 Each
10 Each

43 Each

3 Each

20 Each

35 Each
12 Each

9 Each

12 Each

240 Each
40 Each

30 Each

20 Each

64 Each

450 Mtr.

12 Each

10 Each
32 Each

25 Mtr.
12 Mtr.

2 Each
1 Each

17 Each

10 Each
7 Each

288 Each

34 Each

29 Each

29 Each
85 Each

450 Mtr.
500 Mtr.

75 Mtr.
80 Mtr.

750 Mtr.

88 Mtr.

2 Set

10 Mtr.

10 Mtr.

1100 Mtr.
8 Set

30 Mtr.

20 Mtr.

2 Set

15 Mtr.

10 Mtr.

4 Each

30 Each

130 Mtr.

60 Mtr.

4 Each

40 Mtr.
200 Mtr
250 Mtr

400 Mtr
250 Mtr
200 Mtr

10 Each
8 Each
6 Each

1 Each

1 Each

1 Each

20 Each

40 Each

1600 mtr
4 Set

2 Set

250 mtr

4 Each/set

4 Each/set

4 Each

18 Each

25 Each

4 Each

22 Each

1 Job
2 Each

70 Mtr.

1 Each

1 Each

2 Each

40 Each

2 Each
SCHEDULE OF QUANTITY (Interna

iteam no

1
a)

4
5
a)
b)
c)
d)
6
a)
b)
c)
d)
e)

7
a)
b)

8
a)
9
a)

10
a)

11
a)
b)

12
13
a)

14

15
16
17

18
a)
a)

19
a)
b)

1
A
B
C
D

5
6

10

11

12
13

14

15

16

17

18

19
a)

1
a)
b)

2
a)
b)
3
a)

4
a)
b)

5
a)

6
a)

a)
b)
c)

3
4
a)
b)

5
a)
b)

6
a)

7
a)

10

11

1
2
3

4
5
6

1
a)
b)

2
a)
b)
c)
3
a)
b)
c)

6
a)

1
a)
b)
c)
d)

e)
f)
g)
h)

i)

3
SCHEDULE OF QUANTITY (Internal Electria

SUB-HEAD - I (Wiring )

Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed stee
conductor single core cable etc as required
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, m
required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS

Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS

Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel con
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
3 x 1.5 sq. mm
4 x 1.5 sq. mm
5 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm

Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and mak

20 mm
25 mm

Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ P

2 Pair
Supplying and Laying of one number armoured jelly filled telephone cable confirming to last IFD specification NO > G/CUG-01/02 of Feb 96 of conductor size 0.50 mm

50 Pair

Supplying, Installation, Testing and Commissioning of following size Krone Box with same number of pairs base unit - chrome plated frame enclosed in krone box havin

50 Pairs

Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required..

Telephone socket outlet


Giga speed RJ 45 information outlet with shutter

Supplying/ Fixing of suitable size of modular plates i/c providing & fixing following accessories i/c connection etc. a

Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)

Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outl

Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular so

Supplying and fixing 25 amp. Starter with 4 module GI box in recess and 1 no. 25 Amp 6 pin socket outlet i/c connection etc as required.
Supplying/ Fixing of suitable size of modular type metal box on surface/ recess with modular plates i/c providing & fixing following accessories i/c connection etc. as requ
a) Buzzer 230 V a.c.- 1 No.

Supplying and embedding of following sizes of under floor trunking made out of 1.6 mm thick Hot Dip Galvanised Steel sheet having below mentioned compartment
specifications complete as required.
250 mm wide X 38 mm deep ( 3 Compartments )
150 mm wide X 38 mm deep ( 2 Compartments )

Supplying and fixing of following sizes of under floor junction boxes made out of 1.6 mm thick pre-galvnaized sheet steel, top cover with 2.5 mm thick pre-galvanized st
required.
250 X 250 X 60 - 75 mm ( 3 compartment )
150 X 150 X 60 - 75 mm

SUB-HEAD - II ( FITTINGS)

Supply,installation,testing & commissioning of rimless fixtures of following Diameter with round shaped housing made ofwhite powder coated aluminium suitable for trim
10V or DALI Ballast.Make:XAL (INVISIBLE ROUND)/ARTIMIDE(VIABIZZUNO/ CAMPANA BREMBANA) or equivalent model of ZUMTOBEL
DIA- 160 MM LAMP 18 W
DIA- 260 MM LAMP 22 W
DIA- 350 MM LAMP 40 W
DIA- 450 MM LAMP 60 W

Supply, Installation & commissioning of 1200mm length in extruded aluminium housing and high efficiency opal diffuser ceiling suspended up-down LED light fixture w
0.9 and THD less then 20% and CCT 5000k with Philips / Atco tridonic Dimmable ballast including wire suspension kit in Y-form and transparent cable for suspension h

Supplying and fixing of decorative direct indirect circular luminaire , Reflector: anodized aluminum,Components: polycarbonate. Glare should be controlled in all viewi
wire suspension fully adjustable for suspension length of upto 3 metres Make:TRILUX:POLORON WD2 SUSPENDED/Zumtobel: ONDARIA/OMS :TUBUS VISION PEN

SITC of LED weatherproof IP 66 ,1200 mm fixture having system lumen output of 2000 lumens and efficacy better than 90 lumen/ watt with opal diffuser IN POLYCARB
PVC insulated FRLS PVC sheathed copper conductor cable in flexible GI conduit etc. as reqd.Make :TRILUX( ZALUX ALHAMA LED) /ZUMTOBEL(CHIARO II ) or equiv

Supply, Installation, testing and commissioning of LED Luminaire Consisting of extruded aluminium profiles, very slender appearance white fine powder-coated with
comprising of high power LEDs integrated in separate high performance precision lenses. LED with constant colour stability and a colour rendering index of Ra > 80 ov
luminaire better then 72 lm/W . Electronic power supply integrated within luminaire. With digitally dimmable arrangement. L80 LED mortality B10, Service life 50000 o
equivalent model of XAL/ZUMTOBEL
SITC of 300mm x 300 mm surface type(white colored)LED Luminaire with diecast aluminium construction having system lumen output of 1600 Lumens and efficac
zumtobel/Trilux/endo)

Supplying, installation, testing and commissioning of flat LED panel (edgelit)of 595 x 595 mm size down light with efficacy better than 75 Lumen/watt (minimum total
ballast including making suspansion arrangement with gear wire including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor cable

Supply, Installation, testing and commissioning of Ceiling suspended 1500 mm; "Tunable White" LED luminaire, dynamic variation in colour temperature; symmetric wid
6000K (warm white neutral white daylight white); 60 watt colour rendering: RA90; 50,000h service life at 70% luminous flux; includes controllable ballast, dimma
mechanical connection by ACRYLIC Linear connectors for cover, electrical connection via quick connectors, 2000 mm quick adjustment steel suspension cables,
equivalent models of ZUMTOBEL/ARTEMIDE)

Supplying, Installation, Testing & Commissioning of 1200 mm IP 65 LED Luminaire with Housing and cover made of virgin polycarbonate with Color temperature 6500
current electronic driver with CRI>80 and life of 50K burning hours(L 70) including fixing with conduit / pipe/ surface mounting and connection with 3 x 1.5 sq.mm. PVC
ENDURA or equivalent model of ENDO

Supplying, Installation, Testing & Commissioning of highbay IP 65 integral LED luminaire with high pressure diecast aluminium housing neutral white (4000 K) having s
through DALI compatibility and life of 50K burning hours(L-70) including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor cable .

Supplying, Installation, Testing & Commissioning of circular LED recess down lighter, neutral white of system lumen output of 1500 Lumens with efficacy better than 6
electronic driver with CRI>70 and life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor cable in flex

Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable spot down lighter, neutral white of system lumen output of 850 Lumens with effi
constant current electronic driver with CRI>70 and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed cop
Supplying, Installation, Testing & Commissioning of circular LED recess fixed/adjustable spot down lighter, neutral white of system lumen output of 850 Lumens with effi
constant current electronic driver with CRI>70 and dimmable ballast and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FR

Supplying, Installation, Testing & Commissioning of circular LED recess down lighter, neutral white of system lumen output of 1500 Lumens with efficacy better than 6
electronic driver with CRI>70 and dimmable ballast and expected life of 40K burning hours including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed

Supplying, Installation, Testing and Commissioning of 1200mm LED luminaire made of extruded aluminium housing suitable for 240 Volt AC with system lumens outpu
as reqd. (Make - Philips / Wipro / GE/ Osram)

Supply, Installation,testing& commissioning LED strip for cove 7 watt Per meter with 500 lumens output per meter , CCT 3000k . Supply with driver suitable for 5 m led

Providing & Fixing mirror light with aluminium housing suitable for 14 watt T-5 lamp complete with lamp i/c connection, earthing etc. as reqd (Philips Adreno or equivalen

Supplying and fixing weather proof LED bulk head 10 watt fitting including connection, testing etc. as reqd. (Make - Philips Endura or equivalent of Bajaj/Wipro/GE LED

Supplying, Installation, testing and commissioning of ceiling fan complete with all accessories of following sweep including wiring the down rods of length (upto 30 c
Smart/Usha Energia - ISI)
1200mm sweep. 5-star rated

SUB-HEAD - III (RISING MAIN & DISTRIBUTION BOARDS)

Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type/Sandwich type Rising Mains for use on 3 phase 4 wire 415 vo
aluminium bus bars, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip o
etc. as required
200 amps 15KA SC for 1 sec
400 amps 30KA SC for 1 sec

Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type bus trunking/ rising mains, testing and commissioning of following capacity End
with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to ea

200 amps 15KA SC for 1 sec


400 amps 30KA SC for 1 sec
Supplying, installing, connecting to existing Air Insulated Compact Type/Sandwich type bus trunking/ rising mains, testing and commissioning of following capacity Plu
with provision of MCCB (but without MCCB) complete etc. as required

125 amps 15KA SC for 1 sec

Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder paint
incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door

Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB co

Single pole

Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board/MCB DB/tap off boxes including making connections, etc. as required.
63 Amp, 16 KA TP

Sub Head IV (Compound Lighting)

3
The pole shall be divided in two sections:
Top - Dia 75mm. Length 2000mm (3.2mm thick)
Bottom - Dia 114mm. Length 1000mm (4.0mm thick)
Base plate - 250mm x 250mm x 10mm thick duly welded to cloumn
(Make-Twinkle-Classic Steel 114-302/or its equilalent model of KLITE/ Bajaj)

Supplying, installation, testing and commissioning of 42 watt, warm white with integral driver, closed diffuser, IP65 protection, stylish, robost, Decorative Post Top Lante
including connections with 3 core X 1.5 sq mm PVC insulated PVC sheathed copper conductor round cablefrom looping box to posttop lantern etc. as reqd etc. as reqd

Supplying, Installation, Testing & Commissioning of 8 watt LED bollard fitting with warm white light integral type driver, close diffuser and cast aluminium IP-65 housing 2
7043 or equivalent model of Hadco/zumtobel/ENDO)
Suppplying & Laying of following XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade of following size in the existing DWC
2 x 6 sq mm
2 x 10 sq mm

Supplying & Laying of following XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade of following size on surface as required
2 x 6 sq mm
2 x 10 sq mm

Supplying and Laying of following sizes of DWC corrugated pipe with coupling socket direct in ground i/c excavation in ground i/c refilling the trench for passage of cable
78/63mm dia (OD/ID)

Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required sha
40 mm dia

Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and wateri

Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15 mm dia GI pipe from earth electrode including connection with GI thimble, exca

Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing etc. as required.

Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

SUB-HEAD - V (EARTHING)

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangemen
Conductor)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement
Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I.pipe from earth electrode etc as per specifications complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc as per specifications complete as required.

SUB-HEAD - VI (LIGHTNING CONDUCTOR)

Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate inclu

Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as re

Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

Sub Head VII ( Cables)

Supplying and fixing following sizes of Steel Wire cable trays electro zinc type including couplers, fittings and other accessories as required, and duly suspended fr
betterman

300 mm width X 50 mm depth


150 mm width X 50 mm depth

Supplying and laying of following sizes of XLPE insulated & PVC sheathed glavanised steel strip/wire armoured copper conductor cable of 1.1 KV grade on surface / c

3 x 4 sq.mm.
4 X 6 sq mm
4 X 10 sq mm
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conduct
3 x 4 sq.mm.
4 X 6 sq. mm
4 X 10 sq. mm (25mm)

Sub Head VIII ( Emergency Lighting System, Exit Signage & Networking)

Supplying & Fixing emergency lighting control panel with two lighting lines with minimum of 127 devices on each line. The system shall work on extra low voltage and sh

Supplying and Fixing ELS Panel transformer 230V with an output of 35V ac and capable of providing low voltage supply to the lighting lines.

Supplying and Fixing of Key pad with an LCD to control and read the Main ELS Control Panel

Supplying and Fixing of Addressable Open Area LED Down Lighting compling with BS5266 with integral battery capacity of 2 hrs. and bicoloured LED status indicator

Supplying and Fixing Addressable exit signage visible from 20 mtrs. with integral battery capacity of 2 hrs. and bicoloured LED status indicator

Supplying & drawing Giga speed UTP 4 pair CAT-6 type computer data cable in the existing surface/recessed PVC/steel conduit/ floor trunking/cable tray etc as per
1 x 4 pair

Supplying, Installation, testing and commissioning of Giga Speed 24 Port Patch max Giga Speed Jack Panel including making end termination and connections of d

Supplying, Installation, testing and commissioning of dust and moisture proof 6U Cabinet for the patch panel .

Supplying and fixing 100mm X 50 mm DLP, UPVC cable management trunking on surface with 82 mm cover, Tee, Internal & External angle, Flate angle cable retainer

Sub Head IX Lighting Control System

SITC of following components of lighting control system of distributed intelligence type comprising of input and output control modules featuring an embedded micro
modular relays, modular dimmers, modular input units and modular networking devices as per the enclosed specifications. Make:Given models of Dynalite or equivalen

SITC of Multi controller with 8 channel module having 4 channel relay module and 4 channel dimmer module (dynalite DDMC802 or equivalent model of lutron/Zumtob
SITC of 8 channel trailing edge dimmer each of 2amp (dynalite DDTE802 or equivalent model of lutron/Zumtobel)
SITC of 8 channel 10 amp relay module with din rail mounting arrangement ( dynalite DDRC810 or equivalent model of lutron/Zumtobel)
SITC of programmable capacitive touch switch with different surface finishes and graphic (dynalite Antumbra or equivalent model of lutron/Zumtobel)

Supplying, installation, testing and commissioning of false ceiling mounted PIR type occupancy sensor for a coverage of 45 sq mtr and diametric range of 8 mtr with set
FR-LSH PVC insulated 650/1100 V grade multistranded copper conductor cable complete etc as required. (Make:DYNALITE/ LUTRON/Zumtobel/PHILIPS)

IR Remote Control. (Make:DYNALITE/ LUTRON/ZEMTOBEL)


Supply & fixing of Daylight , IR and occupancy sensor network base with lux setting from 300 lux to 800 lux ( dynalite DDRC810 or equivalent model of lutron/Zumtobe
Software & Hardware required for running of the entire lighting control system of each floor(DESKTOP to be PROVIDED BY CLIENT)(dynalite cosoft or equivalent mode

SITC of AV controller for board room with 4 IR to IP conversion compatibility including providing Ipad ( use as touch screen ) with desired apps to control complete board

Sub Head X WATER INGRESS DETECTION

SITC of Water Leak Sensing Cable/Tape as per specifications

SITC of Electronic Sounder 85db as per specifications

of SITC 4 Zone Water Leak Conventional Panel with Battery Charger & Battery as per specification

Sub Head XI RODENT REPELLANT SYSTEM

Supply, installation, testing and commissioning of Rodent repellant sysytem consisting of VHFO Console along with the indicators incuding termination of the cable

Supply and fixing of satellites above false ceiling, below ceiling and below false flooring.

MS Stand for fixing the master console unit.


557 Pts.

16 Pts.

1000 Mtr.

500 Mtr.

1000 Mtr.
600 Mtr.
100 Mtr.
60 Mtr.

250 Mtr.
120 Mtr.
120 Mtr.
100 Mtr.
1100 Mtr.

1550 Mtr.
1800 Mtr.

1600 Mtr.
250 Mtr.

6 Each

75 Each
100 Each

100 Each

50 Each

12 Each

116 Each

8 Each

47 Each
50 Mtr.
250 Mtr.

12 Each
28 Each

2 Each
2 Each
2 Each
2 Each

55 Each

10 Each

43 Each

3 Each
20 Each

35 Each

12 Each

9 Each

12 Each

240 Each

40 Each
30 Each

20 Each

64 Each

450 Mtr.

12 Each

10 Each

32 Each

25 Mtr.
12 Mtr.

2 Each
1 Each
17 Each

10 Each
7 Each

288 Each

34 Each

29 Each

29 Each

85 Each
450 Mtr.
500 Mtr.

75 Mtr.
80 Mtr.

750 Mtr.

88 Mtr.

2 Set

10 Mtr.

10 Mtr.

1100 Mtr.

8 Set

30 Mtr.
20 Mtr.

2 Set
15 Mtr.
10 Mtr.

4 Each

30 Each

130 Mtr.

60 Mtr.

4 Each

40 Mtr.

200 Mtr
250 Mtr

400 Mtr
250 Mtr
200 Mtr
10 Each
8 Each
6 Each

1 Each

1 Each

1 Each

20 Each

40 Each

1600 mtr

4 Set

2 Set

250 mtr

4 Each/set
4 Each/set
4 Each
18 Each

25 Each

4 Each
22 Each
1 Job

2 Each

70 Mtr.

1 Each

1 Each

2 Each

40 Each

2 Each
SUB-HEAD - I (Wiring )
Iteam No; 18

Supplying and embedding of following sizes of under floor trunking made out of 1.6 mm thick Hot D
fixing supports, chipping and levelling that portion of the floor etc in

Location (NABARD)
250 mm wide X 38 mm deep ( 3 Compartments )
F.Floor

250 cross over box center Point 5.00


Center Point to Left Side 2.10 3.80
Center Point to Left Side 3.40 4.10 2.50
Center Point to Right Side 2.50 2.50
Center Point to Right Side 4.20 4.50
Center Point to State Ahu Room 2 5.80 5.10 0.70
Ahu Room 2 to all area 3.00 1.80 13.10 7.60
center Point To Right Side 1.20 4.00 3.60
Center Point to State 2.50 2.50
center Point To Left Side 4.00 3.90
Server Room To 3rd Line 1.70 6.70 3.00 3.70
Server Room To 4th Line 2.70 3.70
left Side 4.60 3.30
Right side 1.40 4.90 4.50 5.00 3.70 0.80 2.00

F.Floor
Server To Ahu Room 2
Server To 250 cross Over Box
Second Floor

Ahu Room 1 to confrance hall


Ahu Room 1 to hall
Ahu Room 2 to Hall

Total

Supplying and fixing of following sizes of under floor junction boxes m


Iteam No;19
thick pre-galvnaized sheet steel, top cover with 2.5 mm thick pre-galv
alongwith changeover fly-overs including chipping and levelling that po
as per specifications complete as required.
a) 250 X 250 X 60 - 75 mm ( 3 compartment )
First Floor qty
3rd Line 4
2nd line Ahu Room 1 Toahu room 2 14
Ahu Room 2 to Other Area 11
Ahu Room 1 to 4Th Line 14

43
b) 150 X 150 X 60 - 75 mm
First Floor
Server Room To 1st Line 3

Extra Iteam
cross Over box 1st line 2nd line300 X 300 X 60 - 75 mm ( 3 compartment )
combind 2
f 1.6 mm thick Hot Dip Galvanised Steel sheet having below mentioned compartments including Jointing sleeve
on of the floor etc in the floor / in recess etc as per specifications complete as required.

ep ( 3 Compartments ) 150 mm wide X 38 mm deep ( 2 Compartments )

5.00
5.90
10.00
5.00
8.70
11.60
26.70
8.80
5.00
7.90
15.10
6.40
7.90
5.00 2.50 29.80

2.70 10.60 12.30 9.60


2.70 16.30

3.30 5.00 3.80


5.30 5.00 5.00 5.00 5.00 5.50 5.50 2.50
2.50 5.00

###

er floor junction boxes made out of 1.6 mm


ith 2.5 mm thick pre-galvanized steel plate
ping and levelling that portion of the floor etc
omplete as required.
m ( 3 compartment )
5 mm
including Jointing sleeves, floor

ompartments )

35.20
19.00
0.00

12.10
38.80
7.50

###
SUB-HEAD - I (Wiring )
Iteam No; 18

Supplying and embedding of following sizes of under floor trunking made out of 1.6 mm thick Hot Dip Galvanised Steel sheet having below mention
levelling that portion of the floor etc in the floor / in recess etc as per specifications complete as required.

Location (NABARD)
250 mm wide X 38 mm deep ( 3 Compartments )
F.Floor
Server Room To Ahu Room 2 1st Line 1.70
Server room To center Point 5.00
Center Point TO Left Side 4.20 4.50
Center Point TO Right Side 2.10 3.80 2.5 2.50 3.40
4.10 2.50
Center Point To Ahu Room 2 5.80 5.70
Server Room To 3rd Line 6.70 3.00 3.70
Server Room TO 4th Line 2.70 3.70 4.60 0.30 1.40 4.90 4.50
5.00 3.70 0.80 2.00 5.00 5.00 2.50
Ahu Room 2 To 1st Line 1.70 3.00 1.80 ### 7.60 1.20 3.60
4.00 2.50 2.50 4.00 3.90
300 mm box
Second Floor
Ahu Room 1 To 1st Line
Ahu Room To 2nd Line 5.3
Ahu Room 2 To 1st Line 2.50

Total
Iteam No;19

Supplying and fixing of following sizes of under floor junction boxes made out of 1.6 mm thick pre-galvnaized sheet steel, top cover with 2.5 mm thick pre-galvanized steel plate alongwith changeov
as required.
a) 250 X 250 X 60 - 75 mm ( 3 compartment ) 150 X 150 X 60 - 75 mm (2 compartment
First Floor qty T.qty qty

3rd Line 4 4
2nd line Ahu Room 1 Toahu room 2 14 14
Ahu Room 2 to Other Area 11 11
Ahu Room 1 to 4Th Line 14 14

43 43

2nd Floor
Ahu Room 1 To confrance Hall 4
Ahu Room 1 To hall 11

b)
First Floor
Server Room To 1st Line 3

Extra Iteam
300 X 300 X 60 - 75 mm ( 3 compartment )
cross Over box 1st line 2nd line combind 2

Item No-7
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case
required. (For Telephone, Fire alarm, Point wiring & Emergency Lighting)

total in total in
Location c) 32 mm mtr b) 25 mm mtr

Basment
Car Parking
Loose wire box (near stair-1) to Switch board-1
1 (car parking area) for L.Ckt
Loose wire box (near stair-1) to Switch board-2
2 (car parking area) for L.Ckt
Loose wire box (near stair-1) to J.B 3/4 (car
3 parking area) for L.Ckt 15.05 15.05
J.B 3/4 to Switch board-3 (car parking area) for
4 L.Ckt
J.B 3/4 to Switch board-4 (car parking area) for
5 L.Ckt
Loose wire box (near stair-2) to Switch board-
6 5/6 (car parking area) for L.Ckt 9.20 0.80 10.00
Loose wire box (near stair-2) to Switch board-7
7 (car parking area) for L.Ckt

FAN Room
Loose wire box (near stair-2) to Switch board-1
1 (Fan Room area) for L.Ckt
Loose wire box (near stair-2) to Switch board-1
2 (Fan room area) for P.Ckt 14.80 14.8

STORE ROOM NEAR STAIR 2


Loose wire box (near stair-2) to Switch board-1
1 ( Store area) for L.Ckt
Loose wire box (near stair-2) to Switch board-1
2 (Store area) for P.Ckt 5.80 11.55 17.35
A.C Plant Room
Loose wire box (near stair-1) to Switch board-1
1 (A.C Pant area) for L.Ckt 3.20 8.10 2.75 0.40 14.45

2 S.B no 1 TO Store S.B no 1


Loose wire box (near stair-1) to Switch board-2
3 (A.C Pant area) for L.Ckt
Loose wire box (near stair-1) to Switch board-3
4 (A.C Pant area) for L.Ckt
Loose wire box (near stair-1) to Switch board-1
5 (A.C Pant area) for P.Ckt 3.00 3
Loose wire box (near stair-1) to Switch board-2
6 (A.C Pant area) for P.Ckt 3.25 10.70 13.95
STORE ROOM NEAR STAIR 1
Loose wire box (near stair-2) to Switch board-1
1 ( Store area) for P.Ckt 2.95 7.60 4.30 14.85
Telephone Duct 1 To Tele Phone Point 1 (STORE
2 1) 7.50 7.5
Telephone Duct To Tele Phone Point 1 (A.C
3 Room) 8.60 5.90 2.70 17.2

4 DUCT 1 to DUCT 2 14.10 15.00 14.30 43.4

5 DUCT 1 to DUCT 2 14.20 15.00 14.50 43.7


Telephone Duct 2 To Tele Phone Point 1 (STORE
6 Room 2) 5.95 5.95
Telephone Duct 2 To Tele Phone Point 1 (FAN
7 Room) 9.20 8.50 17.7
GROUND FLOOR
FIRE CONTROL ROOM

Loose wire box (near stair-1) to Switch board-1


(Fire control Room) Near lift for L.Ckt

S.B1 TO SB 1

Loose wire box (near stair-1) to Switch board-2


(Fire control Room) Near lift for L.Ckt

Loose wire box (near stair-1) to Switch board-1


(Fire control Room) Near lift for P.Ckt 8.90 0.80 9.7

Loose wire box (near stair-1) to Switch board-1


(Fire control Room) Near lift for P.Ckt 4.90 4.9
Telephone Duct 1 To Tele Phone Point 1 ( Fire
control Room ) 10.98 10.98
Telephone Duct 1 To Tele Phone Point 1 ( Fire
control Room ) 10.98 10.98
STORE ROOM
Loose wire box (near stair-1) to Switch board-1
(Store Room) for L.Ckt
Loose wire box (near stair-1) to Switch board-1
(Store Room) for P.Ckt 15.30 14.30 0.80 8.60 39
RECPECTION AREA
Loose wire box (near stair-1) to Switch board-1
(Recpectipon Area) for L.Ckt
Loose wire box (near stair-1) to Switch board-1
(Recpectipon Area) for P.Ckt 14.90 6.70 0.80 22.4
Loose wire box (near stair-1) to Switch board-2
(Recpectipon Area) for P.Ckt 14.10 0.80 14.9
Telephone Duct 1 To Tele Phone Point 1
(Recpectipon Area ) 11.60 0.80 12.4
Telephone Duct 1 To Tele Phone Point 2
(Recpectipon Area ) 10.40 0.80 11.2
STAIR CASE

Loose wire box (SUB STATION) to Switch board-


1 (Recpectipon Area) for L.Ckt

Loose wire box (SUB STATION) to Switch board-


1 (Recpectipon Area) for L.Ckt
NEAR AHU ROOM
Loose wire box (near stair-1) to Switch board-1
(NEAR AHU ROOM 1) for P.Ckt 10.20 0.80 11
Telephone Duct To Tele Phone Point 1 (Near
Ahu Room 1) 15.10 0.80 15.9
Telephone Duct To Tele Phone Point 2 (Near
Ahu Room 1) 15.10 0.80 15.9
AHU ROOM 1
Loose wire box (near stair-1) to Switch board-1
( AHU ROOM 1) for P.Ckt 12.80 0.80 13.6
Loose wire box (near stair-1) to Switch board-1
( AHU ROOM 1) for L.Ckt
NEAR AHU CORRIDOR

Loose wire box (near stair-1) to Switch board-1


( AHU ROOM CORRIDOR) for L.Ckt

Loose wire box (SUB STATION) to Switch board-


1 ( AHU ROOM CORRIDOR ) for L.Ckt
SUB STATION
Telephone Duct To Tele Phone Point 1 (SUB
STATION) 15.00 6.70 21.7

Loose wire box (SUB STATION) to Switch board-


2 ( SUB STATION ) for L.Ckt
Loose wire box (SUB STATION) to Switch board-
3 ( SUB STATION ) for L.Ckt

Loose wire box (SUB STATION) to Switch board-


1 ( SUB STATION ) for P.Ckt 3.10 3.1

Loose wire box (SUB STATION) to Switch board-


2 ( SUB STATION ) for P.Ckt 7.30 7.3

Loose wire box (SUB STATION) to Switch board-


4 ( SUB STATION ) for P.Ckt 8.70 0.40 9.10
CORRIDOR HALL
Loose wire box (near stair-2) to Switch board-1
(CORRIDOR HALL) for P.Ckt 1.80 5.40 2.20 9.4
S.B 1 TO S.B 2 7.40 12.90 20.3
Loose wire box (near stair-2) to Switch board-3
(CORRIDOR HALL) for P.Ckt 7.30 0.40 2.90 10.6
Loose wire box (near stair-2) to Switch board-4
(CORRIDOR HALL) for P.Ckt 5.80 0.40 2.90 1.85 10.95
Loose wire box (near stair-2) to Switch board-5
(CORRIDOR HALL) for P.Ckt 5.80 0.40 9.20 15.4
Loose wire box (near stair-2) to Switch board-6
(CORRIDOR HALL) for P.Ckt 5.80 0.40 3.00 9.2
Loose wire box (near stair-2) to Switch board-7
(CORRIDOR HALL) for P.Ckt 7.70 7.7
Loose wire box (near stair-2) to Switch board-1
(CORRIDOR HALL) for L .Ckt
Loose wire box (near stair-2) to Switch board-1
(NEAR DUCT WALL) for L.Ckt
Telephone Duct 2 To Tele Phone Point 1 (SUB
STATION)
Telephone Duct 2 To Tele Phone Point 2 (SUB
STATION) 12.10 0.80 12.9
Telephone Duct 2 To Tele Phone Point 3 (SUB
STATION) 12.30 0.80 13.1
Telephone Duct 2 To Tele Phone Point 4 (SUB
STATION) 7.50 0.80 8.3
Telephone Duct 2 To Tele Phone Point 5 (SUB
STATION) 7.10 0.80 7.9
Telephone Duct 2 To Tele Phone Point 6 (SUB
STATION) 2.10 0.80 2.9
Telephone Duct 2 To Tele Phone Point 7 (SUB
STATION) 2.10 0.80 2.9
DUCT TO DUCT 15.20 4.40 10.40 30
DUCT TO DUCT 15.20 4.40 10.40 30
AHU ROOM 2
Loose wire box (near stair-2) to Switch board-1
(AHU ROOM 2) for L.Ckt
CORRIDOR
Loose wire box (near stair-2) to Switch board-1
(CORRIDOR) for L.Ckt
Loose wire box (near stair-2) to Switch board-1
(CORRIDOR) for L.Ckt
Loose wire box (near stair-2) to Switch board-1
(CORRIDOR) for P.Ckt 2.75 9.75 0.80 13.3
Loose wire box (near stair-2) to Switch board-2
(CORRIDOR) for P.Ckt 3.10 4.90 6.20 0.40 14.6

Switch board-2 to Switch Board 3 for P.Ckt 5.30 0.80 6.1


Loose wire box (near stair-2) to Switch board-4
(CORRIDOR) for P.Ckt 1.10 10.20 4.60 6.20 0.40 22.5

Switch board-4 to Switch Board 5 for P.Ckt 2.20 0.80 3


Telephone Duct 2 To Tele Phone Point 1
(CORRIDOR) 2.50 15.70 8.65 0.45 27.3
Telephone Duct 2 To Tele Phone Point 2
(CORRIDOR) 15.00 8.65 0.40 24.05
Telephone Duct 2 To Tele Phone Point 3
(CORRIDOR) 15.00 8.65 0.40 24.05
Telephone Duct 2 To Tele Phone Point 4
(CORRIDOR) 15.00 13.30 0.80 2.50 31.6
Telephone Duct 2 To Tele Phone Point 5
(CORRIDOR) 15.00 12.00 0.80 2.50 30.3
Telephone Duct 2 To Tele Phone Point 6
(CORRIDOR) 2.50 15.00 15.00 0.80 33.3
BATH ROOM 1
Loose wire box (near stair-1) to Switch board-1
(BATH ROOM 1) for L.Ckt
Loose wire box (near stair-1) to Switch board-2
(BATH ROOM 1) for L.Ckt
FIRST FLOOR
Loose wire box (near stair-1) to Switch board-1
(AHU ROOM 1) for L.Ckt
CORRIDOR HALL
Loose wire box (near stair-2) to Switch board-1
(Corridor hall) for L.Ckt
AHU ROOM 2
Loose wire box (near stair-2) to Switch board-1
(AHU ROOM 2) for L.Ckt
BATH ROOM 2
Loose wire box (near stair-2) to Switch board-1
(BATH ROOM 2) for L.Ckt
Loose wire box (near stair-2) to Switch board-2
(BATH ROOM 2) for L.Ckt
DUCT TO DUCT 20.10 13.40 0.40 8.70 42.6
DUCT TO DUCT 20.10 0.40 13.80 0.40 1.50 8.70 44.9
BATH ROOM 1
Loose wire box (near stair-1) to Switch board-1
(BATH ROOM 1) for L.Ckt
Loose wire box (near stair-1) to Switch board-1
(BATH ROOM 1) for L.Ckt
Second Floor
Loose wire box (near stair-2) to Switch board-1
(BATH ROOM 2) for L.Ckt
4 9.6 9.6
U.P.S Duct To AHU room 1 for p.Ckt 29.50 29.50
U.P.S Duct To AHU room 1 for p.Ckt 29.50 29.50
Telephone Duct to Cable tray 10.10 10.10
Telephone Duct to Cable tray 10.10 10.10
Ahu Room 1 0.00
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To cross Over Box 4.20 4.20
Cross Over Box To Ahu D.B Power Point 2.10 2.10
Cross Over Box To Ahu D.B Power Point 2.10 2.10
Cross Over Box To Ahu D.B Power Point 2.10 2.10
Cross Over Box To Ahu D.B Power Point 2.10 2.10
Crs Over Box To Cross Over Box TP
light point Total fan point exhaust fan point
in call bell point
Nos.
Location Basment
Parking Area
S.B no 1 7 7
S.B no 2 3 3
S.B no 3 7 7
S.B no 4 4 4
S.B no 5 4 4
S.B no 6 4 4
S.B no 6 8 8
S.B no 7 2 2
Store Room Stair 2 0
S.B no 1 6 6 3
FAN Room
S.B no 1 4 2
A.C Plant Room
S.B no 1 6 3
S.B no 2 7 3
S.B no 3 6 3

Store Room Stair 1


S.B no 1 8 3

Ground Floor
Compulsary Corridor
S.B no 1 3
S.B no 1 3
S.B no 1 3
S.B no 1 3
S.B no 1 2
AHU.Room 2
S.B no 1 1 1
Ouer Area R.H.S
S.B no 4 3
S.B no 4 3
S.B no 4 3
S.B no 4 3
S.B no 2 4 2
S.B no 6 3 1
S.B no 1 3 1
S.B no 1 2 1
S.B no 1 3 1 1
AHU.Room 1
S.B no 1 1 1
Fire Room
S.B no 1 2 1
S.B no 2 2 1
Near Lift 2
S.B no 1 3 1
Near Lift 1
S.B no 1 2 2

Total

SUB-HEAD - II ( FITTINGS)
Iteam No10
Supplying, Installation, Testing & Commissioning of highbay IP 65 integral LED luminaire with high pressure diecast aluminium housing neutral white (4000 K) having system lumen output of 1400
efficacy better than 100 lumen/ watt THD <20% PF >0.95,CRI >80 with inbuilt intelligence through DALI compatibility and life of 50K burning hours(L-70) including connection with 3 x 1.5 sq.mm. P
FRLS PVC sheathed copper conductor cable . as reqd. (Make - Philips (Maxolid Highbay) or equivalent models of zumtobel or ENDO

Location Qty

Oll Side Bulding Porch Area 12


eet having below mentioned compartments including Jointing sleeves, floor fixing supports, chipping and

150 mm wide X 38 mm deep ( 2 Compartments )

1.70 10.6 12.3 9.6 32.5


5.00 16.3 16.3
8.70
20.90

11.50
13.40 1.7 1.7
46.10

48.90

0.00
0.00 3.30 5.00 3.80 12.1
5.30 5.00 5.00 5.00 5.00 5.50 5.50 2.50 33.5
2.50 2.50 5.00 7.5

164.00 103.6

zed steel plate alongwith changeover fly-overs including chipping and levelling that portion of the floor etc as per specifications complete

X 150 X 60 - 75 mm (2 compartment
and making good the same in case of recessed conduit as

total in
a) 20 mm mtr

5.80 0.00

9.90 0.00

1.30 1.30

3.30 3.30

3.75 2.30 6.05

5.70 0.80 6.50

5.80 11.55 17.35


3.10 3.10

3.00 0.70 3.70

8.90 0.80 2.80 12.50

1.20 1.20

4.90 4.90
15.30 14.30 0.80 8.60 39.00

14.90 8.70 0.80 24.40

9.50 8.50 0.80 18.80

2.00 9.50 8.50 0.80 20.80

13.70 0.80 14.50

9.60 0.80 10.40

8.80 8.80
15.00 1.85 16.85

4.30 4.30
8.90 0.80 9.70

6.20 0.80 7.00

6.20 0.80 7.00

7.90 7.90

7.10 0.80 7.90

15.30 15.30

23.80 15.40 0.40 39.60

3.20 16.70 19.90

18.20 18.20

9.60 9.60
1.50 0.80 2.30

7.10 0.80 7.90

10.3 10.30

250*
Total in
call bell point
Nos.
aving system lumen output of 14000 lumens with
ng connection with 3 x 1.5 sq.mm. PVC insulated
l or ENDO

You might also like