You are on page 1of 8

Where to buy > See the product page >

Data Sheet

Optimux-108, Optimux-106
Fiber Multiplexer for 4E1/4T1 and Ethernet or Serial Data

Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link
Various fiber interfaces: multimode, single-mode (up to 120 km), and/or
single-mode over single fiber, using SFP optical modules
Automatic link backup with optional hot-swappable second main link
Fiber Multiplexers,
Power redundancy with optional second wide-range power supply
Transmit Any Traffic Management via ASCII terminal, dedicated Ethernet port, SNMP management
station, or a Web-based remote access terminal
over Fiber
The Optimux-108 and Optimux-106 For transmission reliability, an optional
multiplexers combine four E1 or T1 modular second link provides automatic
channels and an optional Ethernet link backup upon link failure. An optional
over a fiber optic uplink. second power supply provides power
A pair of Optimux units provides a simple redundancy for failsafe operation.
and low-cost solution for connectivity over Each of the four signals of the tributary
distances of up to 120 km (74.5 miles). interface is transmitted independently, so
that each channel can be set to a
different clock source.
Optimux-108, Optimux-106
Fiber Multiplexer for 4E1/4T1 and Ethernet or Serial Data

MARKET SEGMENTS AND Single fiber (SF3 option) using SC/APC MANAGEMENT AND SECURITY
APPLICATIONS (Angle-Polished Connector) Optimux-108/106 can be configured and
Typical users of the Optimux-108/106 technology, with a 1310 nm laser monitored locally using an ASCII terminal
fiber multiplexers for 4E1/4T1 and diode for single wavelength operation connected to the control port or remotely
Ethernet or serial data include Single fiber (SF4, SF5 options) using a via the Ethernet management port using:
transportation and utility companies, 1310 nm and 1550 nm long haul laser RADview-EMS running in a
government and universities, Internet diode transmitter with WDM Windows or Unix environment
Service Providers (ISPs), and carriers technology.
extending data and voice from SDH Web-based remote access terminal
Optimux-108 can be ordered with
networks or backhauling cellular traffic. balanced or unbalanced E1 tributary Telnet.
Figure 1 and Figure 2 illustrate interfaces. Optimux-106 has balanced T1 To enhance security, a password to
Optimux-108/106 in typical applications. tributary interfaces. control access to the Optimux-108/106
Optimux-108/106 can be ordered with an management functions can be specified.
INTEROPERABILITY
additional Ethernet user port (VLAN In addition, the security of the site can be
Optimux-108/106 operates with transparent), or with a V.35 interface in enhanced by limiting remote management
OP-108C/106C modules of LRS-102 and place of the Ethernet user port. to specific management terminals or
Megaplex-4100 access nodes. nodes.
RESILIENCY
UPLINK AND TRIBUTARIES MONITORING AND DIAGNOSTICS
Two independent power supplies can be
Optimux-108/106 supports a variety of installed to Optimux-106/108 for To facilitate system diagnostics,
built-in optical uplink interfaces including: redundancy. Optimux-108/106 features LED status
850 nm VCSEL (Vertical Cavity Surface In the uplink redundancy option, indicators, alarms generation and
Emitting Laser) for multimode fiber Optimux-108/106 supports fully automatic recognition, and dry contact closure upon
switching between the main and the link failure.
Note: Available with FC/PC connector only.

1310 nm LED for multimode fiber backup link. Optimux-108/106 features comprehensive
test and diagnostics capabilities that
1310/1550 nm laser diode or long haul TIMING AND SYNCHRONIZATION include local and remote loopbacks on the
laser diode for extended range over uplink interface and on each E1/T1
single-mode fiber The uplink interface features only internal
timing mode.The clock of each E1 channel tributary link. A local loopback can also be
Single fiber (SF1, SF2 options) using a is independent for each channel and activated on the optional V.35 user port.
1310 nm and 1550 nm laser diode transferred transparently.
transmitter with WDM technology,
which enables the laser to transmit the The V.35 interface supports internal,
signal at a different wavelength than external, and loopback timing modes.
the receive signal

Head Office
Control Center

Building A
LAN
Internet
NMS

ETH ETH
PC
Router
Router
Fiber Optic Link up to 4 x E1/T1
4 x E1/T1
120 km (74.5 miles)
TDM
Fiber Optic Backup Link
OP-108 Video
OP-108
PBX OP-106 PBX Camera
OP-106

Figure 1. Ethernet, Voice, Data and Video Services over Fiber


Data Sheet

ETHERNET USER INTERFACE


Specifications Impedance
E1 balanced, 120 Type
FIBER OPTIC INTERFACES T1 balanced, 100 10/100BaseT
E1 unbalanced, 75
Characteristics Connector
See Table 1 Jitter Shielded RJ-45
ITU-T Rec. G.823
Compliance Throughput
G.955, G.742 (Optimux-108 without Connectors Optimux-108: 100 Mbps
Ethernet ports) Optimux-108 Optimux-106: 75 Mbps
E1 balanced: RJ-45 Max. Frame Size
E1/T1 USER INTERFACES E1 unbalanced: a pair of BNC 1536 bytes
Number of Ports Optimux-106
4 RJ-45 SERIAL USER INTERFACE

Line Rate Compliance Type


E1: 2048 kbps G.703, G.823 (E1), G.824 (T1) V.35 DCE
T1: 1544 kbps
Connector
Line Coding Smart Serial
E1: HDB3
Throughput
T1: B8ZS
2.048 Mbps

Branch
FE
Fiber
Up to 120 km E1/T1
Optimux-108/
Headquarters Optimux-106 Router
n x E1/T1
PBX

PBX Branch
n x ETH
Fiber FE

Up to 120 km E1/T1
NMS LAN Optimux-108/
Switch Optimux-106 Router
LRS-102 with
GbE OP-108C/106C
PBX

Branch
FE
IP/MPLS Fiber
Up to 120 km E1/T1
Optimux-108/
Optimux-106 Router

PBX

Figure 2. Corporate Service Sharing


Optimux-108, Optimux-106
Fiber Multiplexer for 4E1/4T1 and Ethernet or Serial Data

MANAGEMENT TIMING DIAGNOSTICS

Autentification Uplink Alarms


Password Internal timing mode Alarm buffer
Manager list
E1 Channel Alarm Relay
Control Port Transparent, independent for each Normally-closed/normally-open contacts
Interface: RS232 DCE asynchronous channel for major and minor alarm indication
Rate: 9.6, 19.2, 38.4, 57.6, 115.2 kbps Connector: RJ-45
V.35 Interface
Connector: Mini-USB 5 Contact rating: maximum 0.5A (at 30 VDC
Internal
or 30 VAC) through closed contacts
Ethernet Management Port External
Type: 10/100BaseT Loopback timing Events
Connector: shielded RJ-45 Event log
Max. Frame Size: 1536 bytes RESILIENCY
Power supply redundancy
Uplink redundancy

Table 1. Standalone Fiber Optic Interface Characteristics

Fiber Type Trans- Typical Receiver Receiver Typical Max. Typical Max. Connector Extended
Wavelength mitter Power Sensitivity w/o Sensitivity with Range w/o USER Range with Type Temperature
Type Output USER ETH port USER ETH port ETH port USER ETH port Version
[nm] [m] [dBm] [dBm] [dBm] [km] [miles] [km] [miles]
850 62.5/125 Laser -6 -34 -32 6 3.7 2 1.2 FC/PC No
multimode (VCSEL)
1310 9/125 single Laser -12 -34 -28 47 29.2 20 12.4 ST, SC, Yes
mode FC/PC
1310 62.5/125 LED -18 -32 -30 7 4.3 2 1.2 ST, SC No
multimode
1550 9/125 single Laser -12 -34 -28 47 29.2 20 12.4 ST, SC, Yes
mode FC/PC
1310 9/125 single Laser (long -2 -34 -34 72 44.7 40 24.8 ST, SC, Yes
mode haul) FC/PC
1550 9/125 single Laser (long -2 -34 -34 120 74.5 80 49.7 ST, SC, Yes
mode haul) FC/PC
Tx 1310 9/125 single Laser WDM -12 -34 -28 47 29.2 20 12.4 SC No
Rx 1550 mode (SF1)
Tx 1550 9/125 single Laser WDM -12 -34 -28 47 29.2 20 12.4 SC No
Rx 1310 mode (SF2)
1310 9/125 single Laser (SF3) -12 -27 -27 20 12.4 20 12.4 SC/APC only No
mode
Tx 1310 9/125 single Laser WDM -2 -36 -34 76 47.2 40 24.8 SC Yes
Rx 1550 (long haul
mode
SF4)
Tx 1550 9/125 single Laser WDM -2 -36 -34 76 47.2 40 24.8 SC Yes
Rx 1310 (long haul
mode
SF5)
Note: Typical ranges are calculated according to attenuation of 3.5 dB/km for 850 nm multimode fiber, 0.4 dB/km for 1310 nm single mode fiber, and 0.25 dB/km for
1550 nm single mode fiber.
Data Sheet

GENERAL Indicators Physical


Environment Front Panel: Plastic enclosure:
Temperature: 0 to 55C (32 to 131F) PWR Height: 4.37 cm (1.7 in)
On (green): both power supplies OK Width: 21.7 cm (8.5 in)
Extended temperature range (metal
On (red): power supply A fault Depth: 17.0 cm (6.7 in)
enclosure only): -20 to 65C (-4 to
On (yellow): power supply B fault Weight: 0.5 kg (1.1 lb)
149F)
Off: Both power supplies fault or no Metal enclosure:
Note: The extended temperature range for
power Height: 4.37 cm (1.7 in)
Optimux-108 with V.35 interface is
LOS/AIS LINK A/B Width: 21.5 cm (8.4 in)
10 to 60C (14 to 140F)
On (red): Sync/Signal Loss on Link A/B Depth: 15.3 cm (6.0 in)
Humidity: Up to 90%, non-condensing On (yellow): AIS detected (products Weight: 0.7 kg (1.5 lb)
without Ethernet port only)
Power
Off: normal operation
Wide range power supply
LOS/AIS CH1 to CH4
AC: 100 to 240 VAC
On (red): Signal Loss on channel
DC: -48 VDC (-40 to -125 VDC)
On (yellow): AIS received on channel
24 VDC power supply
Off: normal operation
24 VDC (20 to 36 VDC)
Rear Panel:
Sig Link A/B (on the fiber optic module) Power Consumption
On (green): signal exists on Link A/B Wide range power supply
Off: no signal on Link A/B AC: 25 VA max
LINK/ACT DC (-48 VDC): 9W max
On (yellow): link is up 24 VDC power supply
Off: link is down 9W max
Blinking: frames are transmitted
100
On (green): 100 Mbps mode
Off: 10 Mbps mode
Optimux-108, Optimux-106
Fiber Multiplexer for 4E1/4T1 and Ethernet or Serial Data

E1/T1

Metro
Ethernet 2G BTS

E1/T1 IMA

Optimux-108/
2G BSC Optimux-106 3G Node B
n x FE WiMAX
Ethernet

Transport n x E1/T1 Fiber


Network

Fiber
Switch
LRS-102 with
3G BSC OP-108C/OP-106C
Optimux-108L
4 x E1

2G BTS

Figure 3. Cellular Range Extension over Fiber

Table 2. Optimux Comparison Table

Feature OP-108L OP-108/106 OP-134/125 OP-1032/1025 OP-45/45L OP-1551 OP-1553

Uplink Fiber Optic Fiber Optic E3, Fiber Optic Fiber Optic T3, Fiber Optic Copper, Copper,
STM-1/OC-3 STM-1/OC-3
Bandwidth (Mbps) 108 108/106 34/25 or 134/125 Proprietary 45 155 155
User interfaces 4E1, ETH 4E1/4T1, ETH 16E1/16T1, ETH 16E1/16T1, ETH 21E1/28T1 21/42/63E1 3E3/3T3
28/56/84T1
Special features Reduced power Redundant, Full bandwidth, 3xGbE User Ring support Full redundancy Full redundancy
consumption hot-swappable Ethernet license interfaces (Optimux-45)
cost-effective uplinks activation
Card version for Works with
LRS-102/MP-4100 OP-108C
Data Sheet

SPECIAL CONFIGURATIONS
Ordering + Fiber optic link interface:
85L 850 nm, multimode, VCSEL
OP-108/~/^/%/!/#/+/$/*/?
RECOMMENDED CONFIGURATIONS Note: Available with FC/PC connector only.
Fiber multiplexer for 4 E1 and Ethernet or
OP-108/B/ETH/FC/13L serial data 13 1310 nm, multimode, LED
OP-108/U/FC/13L Note: Available with ST and SC connectors only.
OP-106/~/%/!/#/+/$/*/?
OP-108/U/ETH/FC/13L/ME
Fiber multiplexer for 4 T1 and Ethernet 13L 1310 nm, single mode, laser
OP-108/B/ETH/SC/SF1
diode
OP-108/B/ETH/SC/SF2 Uplink Modules 15L 1550 nm, single mode, laser
OP-106/ETH/ST/13L OP-108-M/#/+/$/? diode
OP-106/SC/13L OP-106-M/#/+/$/? 13LH 1310 nm, single mode,
OP-106/SC/SF3
Legend long-haul laser diode
OP-106/ETH/SC/13L
~ Power supply (Default=AC/DC 15LH 1550 nm, single mode,
OP-106/R/SC/13L
wide-range power supply): long-haul laser diode
24 24 VDC SF1 Transmit 1310 nm laser (WDM),
receive 1550 nm
^ E1 connector: SF2 Transmit 1550 nm laser (WDM),
B Balanced (RJ-45) receive 1310 nm
U Unbalanced (BNC) SF3 Transmit and receive at 1310 m
laser diode
% Redundant power supply:
(Default=one power supply) SF4 Transmit 1310 nm laser (WDM),
R Redundant power supply of the receive 1550 nm, long haul
same type (not for 24 VDC)
SF5 Transmit 1550 nm laser (WDM),
! Optional user port: receive 1310 nm, long haul
ETH 10/100BaseT Ethernet
Note: For single fiber applications, a device
V35 V.35 (Optimux-108 only)
with SF1 interface is always used opposite a
# Uplink interface connector device with SF2 interface, and vice versa. An
ST ST type connector SF3 interface works only opposite another SF3
FC FC/PC type connector interface.
SC SC type connector $ Extended temperature version
Note: ST and FC connectors are not available (Default=no extended temperature
for single fiber options. support):
H Extended temperature support
(13L, 15L, 13LH, 15LH fiber link
versions and metal enclosure only)
* Redundant uplink module
(Default=single uplink)
D Second uplink module (of the
same type as first uplink
module)
? Enclosure (Default=plastic enclosure)
ME Metal enclosure
Data Sheet
Optimux-108, Optimux-106
Fiber Multiplexer for 4E1/4T1 and Ethernet or Serial Data

product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
324-100-08/12 Specifications are subject to change without prior notice. 19882012 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the
SUPPLIED ACCESSORIES OPTIONAL ACCESSORIES RM-33-2
AC power cord Hardware kit for mounting one or two
CBL-AMP-DB25-ISO2110
DC adapter plug plastic units in a 19-inch rack
Cable to connect the Optimux-108 Smart
CBL-MUSB-DB9F Serial interface connector to the user RM-35/@
Control port cable equipment DB-25 connector with ISO Hardware kit for mounting one or two
2110 pinout metal units in a 19-inch rack
CBL-RJ45-DB9/F
CBL-AMP-DB25-TLBS Legend
Alarm port cable
Cable to connect the Optimux-108 Smart @ Rack mount kit (Default=both kits):
CBL-AMP-M34 Serial interface connector to the user P1 Mounting one unit
Cable to connect the Optimux-108 Smart equipment DB-25 connector with Telebras P2 Mounting two units
Serial interface connector to the M34 pinout
connector of the user equipment WM-35-TYPE4
Hardware kit for mounting 8.5-inch units
in metal enclosure on a wall

International Headquarters North America Headquarters


24 Raoul Wallenberg Street 900 Corporate Drive
Tel Aviv 69719, Israel Mahwah, NJ 07430, USA
Tel. 972-3-6458181 Tel. 201-5291100
Fax 972-3-6498250, 6474436 Toll free 1-800-4447234
E-mail market@rad.com Fax 201-5295777
E-mail market@radusa.com

www.rad.com Order this publication by Catalog No. 803830