Overview

THE STORY OF A COMPANY.


THE STANDARD OF AN INDUSTRY.
AHI Carrier S.E. Europe S.A.

May 2015
Overview
Carrier VRF Products Line UP
VRF Inverter (series K)

Max capacity 72HP


8, 10HP 12, 14, 16HP 18HP

6 module 8, 10, 12, 14, 16, 18HP.


Combinable up to 72HP.
380-415V, 50Hz,3ph.
VRF Full Inverter (series S)

Max capacity 72HP


8, 10HP 12, 14, 16HP 18HP

6 module 8, 10, 12, 14, 16, 18HP.


Combinable up to 72HP.
380-415V, 50Hz,3ph.
VRF Full Inverter (Individual series)

Max capacity 24HP


20, 22, 24HP

3 module 20, 22, 24HP.


Non Combinable.
380-415V, 50Hz,3ph.
Compressor & fan motor comparison

Size Part K series S series Individual *


Compressor Inverter Inverter
8 / 10 HP Fan DC DC
N/A

12HP

14HP
Compressor Inverter + Fix Speed Inverter + Inverter
N/A
Fan DC + AC DC + DC
16HP

18HP

20HP

Compressor Inverter + 2x Fix Speed


22HP Fan
N/A N/A
DC + AC

24HP

* Available upon request & order entry


Excellent Performance

Blades with sharp edge for bigger airflow,


low vibration & resistance.

DC fan motor, low noise, low consumption

Simplified Electronic Architecture

High efficiency heat-exchanger

8
High Efficiency DC inverter compressor
Excellent Performance

Wide operation temp. range


Easy Installation and Maintenance

Piping length Permitted value


Total pipe length 1000 m
Max. actual pipe length 175 m
Max. equivalent pipe length 200 m
Equivalent piping length from the farthest
40 m / 90 m
IDU to the first indoor branch joint

Equivalent piping length from MS to the


40 m
farthest downstream IDU
110 m
(when ODU is down)
Level difference between CDU and IDU
70 m
(when ODU is up)

Level difference between IDUs 30 m


High Comfort

Various mode selection Cooling priority


mode

Lock Cooling Heating priority


mode mode (default)

First on-indoor
Lock Heating
unit priority
mode
mode

Bigger capacity requirement


priority mode

VIP indoor (e.x. address No. 63)


priority mode
3 Pipe VRF System / Heat Recovery

Max capacity 64HP

5 module 8, 10, 12, 14, 16HP.


Combinable up to 64HP.
380-415V, 50Hz,3ph.
3 Pipe VRF System / Heat Recovery

Wide operation temp. range

Piping length Permitted value


Total pipe length 1000 m
Max. actual pipe length 175 m
Max. equivalent pipe length 200 m
Equivalent piping length from the farthest
40 m / 90 m
IDU to the first indoor branch joint

Equivalent piping length from MS to its


40 m
farthest downstream IDU
110 m
(when ODU is down)
Level difference between CDU and IDU
70 m
(when ODU is up)

Level difference between IDUs 30 m


3 Pipe VRF System / Heat Recovery

High efficiency Mode Switch (MS) Box


Multiple groups of indoor units, with 1/2/4/6 ports, up to 24 indoor units to one MS.
Up to 56kW capacity single indoor unit to one MS box.

Max. IDU No. Indoor unit connection


No. of Dimension (mm)
Photo MS model of each
Group/Port L*W*H Total capacity No. of IDU
Group/Port

MSFT-01C-CM 1 4 16kW 1~4

630 x 605 x 225


MSFT-02C-CM 2 4 28kW 1~8

MSFT-04C-CM 4 4 45kW 1~16


960 x 605 x 225
MSFT-06C-CM 6 4 45kW 1~24

MSFT-02E-CM 2 - 630 x 605 x 225 28kW 1

MSFT-04E-CM 4 - 960 x 605 x 225 56kW 1


3 Pipe VRF System / Heat Recovery

Rotating electric
control box

Easy access

Continuous heating during defrost operation,


Each heat exchanger is defrosted by using heat transferred from one heat
exchanger to the other in the CDU.
3 Pipe VRF System / Heat Recovery

MS box working principle:

IDU installed in different MS box can run in different mode (IDU 1 - 6),

IDU installed in the same MS box can run in different mode (IDU 3, 4, 5, 6),
IDU installed in the same port/group will run in the same mode (IDU 3.1-3.4, 6.1-6.4)

MSFT-04E-CM MSFT-02E-CM MSFT-04C-CM

C H OFF C OFF H

IDU 1 IDU 2 IDU 3 IDU 4 IDU 5 IDU 6


(Max.1) (Max.1) (3.13.4) (4.14.4) (5.15.4) (6.16.4)
Excellent Performance

High efficient heat exchanger with inner


grooved copper pipe for high heat exchange
surface,

Blue fin.
Easy Installation and Maintenance

Changeable static pressure


of CDU fan

Optional ESP
0 20 Pa Default Changeable E.S.P.
20 60* Pa Customized

* For 12HP CDU


Easy Installation and Maintenance

Indoor unit auto addressing

The outdoor unit will automatically distribute the addresses to indoor units
without any manual settings.

Wireless controller can enquiry and modify every indoor units address.

Up 64 indoor units can be connected and identified.


Easy Installation and Maintenance

Inspection window

Check window (no need to take out the control box panel) :
Error check,
Test running,
Fix address setting,
Maintenance.

IDU number switch :


The indoor units number should be set on PCB board
before power on,
In case an IDU unit falls down when the system is in
operation the ODU will stop and show fault code H7,
Protection from refrigerant leakage.
Simple Communication Wiring

Only one communication wire (P,Q,E) for both communication of IDU, ODU &
network.
Central controller can be connected through IDU or ODU (X,Y,E terminals).

X,Y,E

X,Y,E
P ,Q, E

P ,Q, E P ,Q, E
P ,Q, E P ,Q, E
High Comfort

Night silent operation :

Activated 6 or 8 hours after the peak temperature during daytime,

Deactivated after 10 or 12 hours.

Lowest noise level


down to 46.8dB(A)
Mini, Side Discharge VRF

220V~1Ph~50Hz @ 12, 14 & 16kW


380V~3Ph~50Hz @ 22,4 & 26kW
380V~3Ph~50Hz @ 12, 14 & 16kW

DC Inverter compressor & fan motor


Mini, Side Discharge VRF

IDU Connectivity

20kW : Up to 10 indoor units


22,4kW : Up to 11 indoor units
26kW : Up to 12 indoor units
40kW : Up to 14 indoor units
45kW : Up to 15 indoor units
Mini, Side Discharge VRF

Flexible installation

Joint

Branch box / collector


Indoor Unit

Diversity 50% ~ 130%


Indoor Unit

Cassette type

From 2,2 ~ 14kW


Indoor Unit

Duct type

From 1,8 ~ 28kW


Indoor Unit

Wall type

From 2,2 ~ 9kW

* Available upon request & order entry


Indoor Unit

Ceiling & Floor


Type

From 2,2 ~ 14kW


Individual Wireless Controls

WL-12-CM WL-14-CM
Function WL-14-CM WL-12-CM
Temperature range 17 ~ 30 17 ~ 30

Time display

Key 26

Controller lock
Eco operation

Swing function

Background-light
Daily timer

Address setting
Fan speed control
Mode selection
Follow me function

standard optional
Individual Wired Controls

WR-10-CM
WR-12-CM

Function WR-10-CM WR-12-CM WR-90-CM WR-29-CM


Temperature range 17 ~ 30 17 ~ 30 17 ~ 30 17 ~ 30
Time display
Controller lock
Eco operation
Swing function
WR-90-CM Background light
(C/D) Daily timer
Follow me function
Fan speed control
Mode selection
Wireless signal

receiver
Dimensions (mm) 120 x 120 120 x 120 85 x 85 120 x 120

WR-29B-CM (touch button)


Central Indoor Wired Controls

CRF-10-CM
Features
Easy installation & connection through IDU or ODU,
Up to 64 IDU, group control or individual setting,
Individual remote control restriction,
Mode lock,
Recovering all settings after power lose,

CRF-30-CM (touch button) IDU status feedback,


ODU status feedback and alarm codes,
RS485 communication,
Background light, parameters display,
Emergency ON/OFF dry contact,
Central Weekly Indoor Wired Control

WCRF-10-CM

Features
Weekly schedule setting,
Up to 64 IDU group control or individual setting,
LCD screen backlight,
Temperature setting,
Individual remote control restriction,
Sleep and Silent mode,
Mode lock,
Recovering all settings after power lose.
Central Outdoor Wired Control

CRC-10-CM

Features
Up to 8 systems or 32 outdoor units,
Operating parameters,
Error codes of outdoor units,
RS485 communication.
Accessories

DX AHU control kit*

* Wired control included


Accessories

Hotel card : NIM05


Digital power meter
Remote on/off dry contact

Move detector: NIM09

KJR-32B (ODU alarm module 220V) CCM15 (data converter)


Accessories

CCM15 Data Converter


Remote control through android device or PC via cloud server

Feature:
AC internet access,
Connection through IDU,
Control up to 64 indoor units,
Real time control,
No distance restriction.
Accessories

CCM15 Data Converter


Remote control through android device or PC via cloud server
IMM Software

Features
AC Control via Internet,
Up to 256 indoor units,
Up to 64 outdoor units,
16 systems per M Interface,
4 M-Interface per PC,
Features of IMM software

User is able to set limits .. Operation Data Record,


Report and Analysis

ex. Upper and lower limit temperature setting: Start / stop control,

Cooling setting Enabling / disabling the remote control.


Temperature: 26~28C Switching the operating mode,
Heating setting Setting temperatures.
Temperature: 22~26C
Features of IMM software

Energy Consumption analysis

Features
ODU consumption measured through Power Meter & send to M-Interface,
IDU consumption & capacity requirement measured through M-Interface,
Energy rated by the ODU to each IDU,
Consumption per tenant charged via M-Interface.
Features of IMM software

3 operation levels
protected via password Able to import AutoCAD
drawing or picture,

Service

Administrator

Direct control of the


User corresponding IDU on the map
Features of IMM software

Emergency Stop
SMS warning message
Alarm signal output

Message warning

Please note: the message alarm function will generate extra cost;
this fee will be charged by the communication service operators.
SMS device state: Has been connected

NO. Name Mobile number Selected to be sent Addition OK


Sending enable

1 Technical support 1582392**** Modification


Sending frequency
2

OK Reset 12345
Features of IMM software

Automatic data backup

In case of power fails or system crashes, the M-interface will automatically


backup the data to the external SD memory card

1. Indoor/outdoor unit name,


2. Power distribution data,
3. Operation history,
4. Power on/off history,
5. System configuration,

Additional, software has an internal back up (PC) of the last 3 months


Gateways Open Protocol

NW-BCN-CM NW-LNW-CM
Modbus gateway
BACnet gateway LonWorks gateway

Feature: Feature: Feature:


Up to 4 group, Up to 1024 IDU or 64 ODU, Up to 64 IDU,
Each group can connect IDU & ODU central Web Access Function,
up to 64 IDU (total 256) or controller are mandatory.
No central control
up to 32 ODU (total 128), requirement.
Web Access Function,
Indoor central controller is
mandatory.
Selection & Diagnosis Software
AHI Carrier S.E. Europe S.A.
THANK YOU