You are on page 1of 4

Catalog HY15-3101/US Counterbalance Valves

Technical Information Series MHB-015

General Description Single Counterbalance

SHUTTLES
CHECKS &
Work Port
MHB-015 series counterbalance valves are load
holding valves with a pilot assist. They can control Pilot
Non- Port
moving loads, prevent loads from running ahead of the Vented
pump, lock loads in any position without drift, and Valve Port
Vent Port Work Port
provide static overload relief and thermal expansion

LOAD & MOTOR


relief with open center directional control valves. Pilot

CONTROLS
Port
Vented
Valve Port

Operation
Valve Port
See Technical Tips.

CONTROLS
VOLUME
Features Optional
Vent Port
Conical Poppet design provides longer metering stroke
Hardened seat provides reliable load holding Pilot Port

External vent option available for high back pressure


applications
Work Port

CONTROLS
PRESSURE
Tamper resistant cap for added safety and security
Symbols
Various pilot ratios available for application flexibility
Non-Vented C C
Dual Counterbalance

SOLENOID
VALVES
Specifications
V V
Rated Flow 46.25 LPM (15 GPM)
Vented C C
Maximum 207 Bar (3000 PSI) Dual Counterbalance
Inlet Pressure

SPECIALTY
VALVES
Leakage 5 drops/min (.33 cc/min.)
@ 207 Bar (3000 PSI)

Operating Temp. -31.7C to +121.1C Vent V V Vent


Range (Ambient) (-25F to +250F)
(Fluorocarbon Seals Only) Performance Curve
Flow vs. Pressure Drop (Through cartridge only)

COILS
Seal Compound Fluorocarbon
PSI Bar Hydraulic Oil 135 SSU @ 100F (28 cSt)
1000 68.9
Valve Material All parts steel. All operating
parts hardened steel.
800 55.2
Body Material Aluminum
Pressure Drop

BODIES

600 41.4
Filtration ISO Code 16/13,
SAE Class 4 or better
400 27.6
Mounting No Restrictions Reverse
Flow 6:1

Cavity None Parts in Body 200 13.8


TECHNICAL

Free Flow
DATA

0
LPM 15 30 45 60 75 82.5
0
GPM 4 8 12 16 20 22
Flow (Q)
mhb-015.pm6.5, bl, gn

Parker Hannifin Corporation


Integrated Hydraulics Division
Hydraulics LM6 Lincolnshire, Illinois 60069 USA

mhb-015.p65 6 9/28/01, 10:03 AM


Catalog HY15-3101/US Counterbalance Valves
Dimensions Series MHB-015

*Inch equivalents for millimeter dimensions are shown in (**)


SHUTTLES
CHECKS &

Series MHB-015-L*A* Single Counterbalance, Non-Vented, In-line Mount


Series MHB-015-W*A* Single Counterbalance, Vented, In-line Mount
MHB-015-L*A* Non-Vented

7.9 22.4
LOAD & MOTOR

(.31) (.88)
CONTROLS

19.1 V
(.75)
46.2
(1.82)
60.3 76.2
(2.38) (3.00)
CONTROLS

7.1 (.28) Dia.


VOLUME

Thru 2
Mtg. Holes

Cylinder Port 7.9 47.6 2.3


(.31) (1.88) (.09)
63.5
(2.50)
CONTROLS
PRESSURE

15.7
31.8 (.62)
P

(1.25)

23.9 74.2
(.94) MHB-015-W*A* (2.92)
SOLENOID

and
VALVES

MHB-015-W*D*
Vented

Series MHB-015-L*D* Dual Counterbalance, Non-Vented, In-line Mount


SPECIALTY

Series MHB-015-W*D* Dual Counterbalance, Vented, In-line Mount


VALVES

25.4 MHB-015-L*D* Non-Vented 16.0


(1.00) (.63)

6.4 19.1
(.25) (.75)

22.4
C1 32.8 (.88)
COILS

(1.29)

17.0 69.9 82.6 37.8 V1 V2


(.67) (2.75) (3.25) (1.49)

C2
BODIES

7.1 (.28) Dia. Thru


2 Mounting Holes
6.4
15.7 (.25)
24.6 25.4
(.62) (.97) (1.00)
57.2 57.2
TECHNICAL

(2.25) (2.25)
DATA

THIRD-ANGLE
PROJECTION

mhb-015.pm6.5, bl, gn

Parker Hannifin Corporation


Integrated Hydraulics Division
Hydraulics LM7 Lincolnshire, Illinois 60069 USA

mhb-015.p65 7 9/28/01, 10:03 AM


Catalog HY15-3101/US Counterbalance Valves
Dimensions Series MHB-015

*Inch equivalents for millimeter dimensions are shown in (**)

SHUTTLES
CHECKS &
Series MHB-015-L*B* Single Counterbalance, Non-Vented, Gasket Mount
Series MHB-015-W*B* Single Counterbalance, Vented, Gasket Mount
MHB-015-L*B* Non-Vented
34.9 19.1
(1.38) (.75)

LOAD & MOTOR


CONTROLS
7.1 (.28) Dia. Thru 22.4
3 Mounting Holes (.88)
V
39.6 97.2
6.4 (1.56)
34.9 (.25) (3.83)
(1.38) 76.2
(3.00)

CONTROLS
VOLUME
3.0
Cylinder Port (.12)
2.4 (.094) CS x
9.5 (.375) ID O-Ring
4.7 17.5 2.3
(.19) (.69) (.09)

CONTROLS
PRESSURE
63.5
(2.50)
15.7
31.8 (.62)
P

(1.25)
74.2
23.9 MHB-015-W*B* (2.92)
and

SOLENOID
(.94)

VALVES
MHB-015-W*E*
Vented

Series MHB-015-L*E* Dual Counterbalance, Non-Vented, Gasket Mount

SPECIALTY
Series MHB-015-W*E* Dual Counterbalance, Vented, Gasket Mount

VALVES
MHB-015-L*E* Non-Vented
25.4 25.4 32.5 76.2
(1.00) (1.00) (1.28) (3.00)

19.1
(.75)

COILS
22.4
36.6 (.88)
(1.44)

82.6 37.8 V1 V2
(3.25) (1.49)
BODIES

9.7
(.38) 7.1 (.28) Dia.
Thru 4
Mtg. Holes
2 Cylinder Ports
2.4 (.094) CS x
9.5 (.375) ID O-Ring
6.4 25.4
(.25) (1.00)
TECHNICAL
DATA

63.5
(2.50)
THIRD-ANGLE
PROJECTION

mhb-015.pm6.5, bl, gn

Parker Hannifin Corporation


Integrated Hydraulics Division
Hydraulics LM8 Lincolnshire, Illinois 60069 USA

mhb-015.p65 8 9/28/01, 10:03 AM


Catalog HY15-3101/US Counterbalance Valves
Ordering Information Series MHB-015

MHB 015
SHUTTLES
CHECKS &

Counterbalance Nominal Vent Pilot Body Holding Porting Pilot


Parts In Body Flow Setting Ratio Style Pressure Port
Rating
LOAD & MOTOR
CONTROLS

Code Type Code Type Code Type

L Non-vented A Single Inline 51 SAE-6


W Vented B Single Gasket 52 SAE-8 (Gasket
mount only)
D Double Inline
04 1/4 NPTF
Code Description E Double Gasket
CONTROLS
VOLUME

015 46.3 LPM (15 GPM)

Code Ratio Code Type

*A 1:1 Equal Area C 17.2 to 34.5 Bar


(250 to 500 PSI)
CONTROLS
PRESSURE

B 3:1 1:1 Pilot only


E 6:1 E 34.5 to 103.4 Bar
J 10:1 (500 to 1500 PSI)

* Equal Area does not H 69 to 210 Bar


have a thermal relief. (1000 to 3000 PSI)
SOLENOID
VALVES

Code Type

N Internal Pilot
(Dual valve only)
E SAE-6 (Code 51
Shipping Weight & 52 bodies only)
Single 0.68 kg (1.5 lbs.)
SPECIALTY

B 1/4 NPTF
VALVES

Double 1.36 kg (3.0 lbs.) (Code 04 body only)


COILS
BODIES
TECHNICAL
DATA

mhb-015.pm6.5, bl, gn

Parker Hannifin Corporation


Integrated Hydraulics Division
Hydraulics LM9 Lincolnshire, Illinois 60069 USA

mhb-015.p65 9 9/28/01, 10:03 AM

You might also like