You are on page 1of 255

ZXWN MSCS

MSC Server
Timer Reference

Version: V4.10.12

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright 2010 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular
purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages
resulting from the use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further
notice. Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History

Revision No. Revision Date Revision Reason


R1.0 2010-10-30 First edition

Serial Number: SJ-20100914141201-031

Publishing Date: 2010-10-30(R1.0)


Contents

Chapter 1 Timers Related with G_MM Module.................................................. 1-1


1.1 Timer 201001 ........................................................................................... 1-1
1.2 Timer 201002 ........................................................................................... 1-1
1.3 Timer 201003 ........................................................................................... 1-2
1.4 Timer 201004 ........................................................................................... 1-3
1.5 Timer 201005 ........................................................................................... 1-3
1.6 Timer 201006 ........................................................................................... 1-4
1.7 Timer 201007 ........................................................................................... 1-4
1.8 Timer 201009 ........................................................................................... 1-5
1.9 Timer 201010 ........................................................................................... 1-6
1.10 Timer 201011 ......................................................................................... 1-6
1.11 Timer 201012 ......................................................................................... 1-7
1.12 Timer 201013 ......................................................................................... 1-8
1.13 Timer 201014 ......................................................................................... 1-8
1.14 Timer 201015 ......................................................................................... 1-9
1.15 Timer 201016 ......................................................................................... 1-9
1.16 Timer 201018 ....................................................................................... 1-10
1.17 Timer 201020 ........................................................................................1-11
1.18 Timer 201021 ........................................................................................1-11
1.19 Timer 201022 ....................................................................................... 1-12
1.20 Timer 201023 ....................................................................................... 1-12
1.21 Timer 201024 ....................................................................................... 1-13
1.22 Timer 201025 ....................................................................................... 1-14
1.23 Timer 201026 ....................................................................................... 1-14
1.24 Timer 201027 ....................................................................................... 1-15
Chapter 2 Timers Related with G_MCC Module................................................ 2-1
2.1 Timer 201031 ........................................................................................... 2-1
2.2 Timer 201032 ........................................................................................... 2-1

I
2.3 Timer 201033 ............................................................................................2-2
2.4 Timer 201034 ............................................................................................2-3
2.5 Timer 201035 ............................................................................................2-3
2.6 Timer 201036 ............................................................................................2-4
2.7 Timer 201037 ............................................................................................2-5
2.8 Timer 201038 ............................................................................................2-5
2.9 Timer 201039 ............................................................................................2-6
2.10 Timer 201040 ..........................................................................................2-6
2.11 Timer 201041 ..........................................................................................2-7
2.12 Timer 201042 ..........................................................................................2-7
2.13 Timer 201043 ..........................................................................................2-8
2.14 Timer 201044 ..........................................................................................2-9
2.15 Timer 201045 ..........................................................................................2-9
2.16 Timer 201046 ........................................................................................2-10
2.17 Timer 201047 ........................................................................................2-10
2.18 Timer 201048 ........................................................................................ 2-11
2.19 Timer 201049 ........................................................................................2-12
2.20 Timer 201050 ........................................................................................2-12
2.21 Timer 201051 ........................................................................................2-13
2.22 Timer 201052 ........................................................................................2-14
2.23 Timer 201053 ........................................................................................2-14
2.24 Timer 201054 ........................................................................................2-15
2.25 Timer 201055 ........................................................................................2-16
2.26 Timer 201056 ........................................................................................2-16
2.27 Timer 201057 ........................................................................................2-17
2.28 Timer 201058 ........................................................................................2-18
2.29 Timer 201059 ........................................................................................2-18
2.30 Timer 201060 ........................................................................................2-19
2.31 Timer 201061 ........................................................................................2-20
2.32 Timer 201062 ........................................................................................2-20
2.33 Timer 201063 ........................................................................................2-21
2.34 Timer 201064 ........................................................................................2-22

II
2.35 Timer 201065 ....................................................................................... 2-22
2.36 Timer 201066 ....................................................................................... 2-23
2.37 Timer 201067 ....................................................................................... 2-23
2.38 Timer 201068 ....................................................................................... 2-24
2.39 Timer 201069 ....................................................................................... 2-24
2.40 Timer 201070 ....................................................................................... 2-25
2.41 Timer 201103 ....................................................................................... 2-25
2.42 Timer 201104 ....................................................................................... 2-26
2.43 Timer 201105 ....................................................................................... 2-26
2.44 Timer 201106 ....................................................................................... 2-27
2.45 Timer 201107 ....................................................................................... 2-27
2.46 Timer 201134 ....................................................................................... 2-28
2.47 Timer 201136 ....................................................................................... 2-29
2.48 Timer 201137 ....................................................................................... 2-29
2.49 Timer 201138 ....................................................................................... 2-30
2.50 Timer 201139 ....................................................................................... 2-31
2.51 Timer 201140 ....................................................................................... 2-31
2.52 Timer 201159 ....................................................................................... 2-32
2.53 Timer 201679 ....................................................................................... 2-33
2.54 Timer 201681 ....................................................................................... 2-33
2.55 Timer 201682 ....................................................................................... 2-34
2.56 Timer 201683 ....................................................................................... 2-35
2.57 Timer 201684 ....................................................................................... 2-37
2.58 Timer 201762 ....................................................................................... 2-39
Chapter 3 Timers Related with G_GMSC Module ............................................. 3-1
3.1 Timer 201071 ........................................................................................... 3-1
3.2 Timer 201072 ........................................................................................... 3-2
3.3 Timer 201073 ........................................................................................... 3-3
3.4 Timer 201074 ........................................................................................... 3-4
3.5 Timer 201076 ........................................................................................... 3-5
3.6 Timer 201077 ........................................................................................... 3-6
3.7 Timer 201078 ........................................................................................... 3-7
III
3.8 Timer 201079 ............................................................................................3-7
3.9 Timer 201080 ............................................................................................3-8
3.10 Timer 201082 ..........................................................................................3-9
3.11 Timer 201083 ........................................................................................3-10
3.12 Timer 201084 ........................................................................................3-10
3.13 Timer 201085 ........................................................................................ 3-11
3.14 Timer 201086 ........................................................................................3-12
3.15 Timer 201087 ........................................................................................3-13
3.16 Timer 201088 ........................................................................................3-13
3.17 Timer 201089 ........................................................................................3-14
Chapter 4 Timers Related with G_MCF Module.................................................4-1
4.1 Timer 201092 ............................................................................................4-1
4.2 Timer 201093 ............................................................................................4-2
4.3 Timer 201094 ............................................................................................4-2
4.4 Timer 201095 ............................................................................................4-3
4.5 Timer 201096 ............................................................................................4-4
4.6 Timer 201097 ............................................................................................4-4
4.7 Timer 201102 ............................................................................................4-5
Chapter 5 Timers Related with G_Common Module .........................................5-1
5.1 Timer 201099 ............................................................................................5-1
5.2 Timer 201100 ............................................................................................5-1
5.3 Timer 201101 ............................................................................................5-2
Chapter 6 Timers Related with G_HO Module ...................................................6-1
6.1 Timer 201111.............................................................................................6-1
6.2 Timer 201112 ............................................................................................6-1
6.3 Timer 201113 ............................................................................................6-2
6.4 Timer 201114 ............................................................................................6-3
6.5 Timer 201115 ............................................................................................6-3
6.6 Timer 201116 ............................................................................................6-4
6.7 Timer 201117 ............................................................................................6-4
6.8 Timer 201118 ............................................................................................6-5
6.9 Timer 201119 ............................................................................................6-5

IV
6.10 Timer 201120 ......................................................................................... 6-6
6.11 Timer 201121.......................................................................................... 6-6
6.12 Timer 201122 ......................................................................................... 6-7
6.13 Timer 201123 ......................................................................................... 6-8
6.14 Timer 201124 ......................................................................................... 6-8
6.15 Timer 201125 ......................................................................................... 6-9
6.16 Timer 201129 ......................................................................................... 6-9
6.17 Timer 201130 ....................................................................................... 6-10
6.18 Timer 201131 ....................................................................................... 6-10
6.19 Timer 201133 ....................................................................................... 6-12
Chapter 7 Timers Related with G_MSCMAP Module ........................................ 7-1
7.1 Timer 201141 ........................................................................................... 7-1
7.2 Timer 201142 ........................................................................................... 7-1
7.3 Timer 201143 ........................................................................................... 7-2
7.4 Timer 201144 ........................................................................................... 7-3
7.5 Timer 201145 ........................................................................................... 7-3
7.6 Timer 201146 ........................................................................................... 7-4
7.7 Timer 201147 ........................................................................................... 7-5
7.8 Timer 201148 ........................................................................................... 7-5
7.9 Timer 201149 ........................................................................................... 7-6
7.10 Timer 201150 ......................................................................................... 7-6
7.11 Timer 201151.......................................................................................... 7-7
7.12 Timer 201152 ......................................................................................... 7-8
7.13 Timer 201153 ......................................................................................... 7-8
7.14 Timer 201500 ......................................................................................... 7-9
Chapter 8 Timers Related with G_VLRMAP Module........................................8-11
8.1 Timer 201161 ..........................................................................................8-11
8.2 Timer 201162 ......................................................................................... 8-12
8.3 Timer 201163 ......................................................................................... 8-12
8.4 Timer 201164 ......................................................................................... 8-13
8.5 Timer 201165 ......................................................................................... 8-13
8.6 Timer 201167 ......................................................................................... 8-14
V
8.7 Timer 201169 ..........................................................................................8-15
8.8 Timer 201170 ..........................................................................................8-15
8.9 Timer 201171 ..........................................................................................8-16
8.10 Timer 201172 ........................................................................................8-16
8.11 Timer 201173 ........................................................................................8-17
8.12 Timer 201174 ........................................................................................8-18
8.13 Timer 201175 ........................................................................................8-18
8.14 Timer 201176 ........................................................................................8-19
8.15 Timer 201177 ........................................................................................8-19
8.16 Timer 201178 ........................................................................................8-20
Chapter 9 Timers Related with G_TM Module ...................................................9-1
9.1 Timer 201211............................................................................................9-1
9.2 Timer 201214............................................................................................9-1
9.3 Timer 201215............................................................................................9-2
9.4 Timer 201216............................................................................................9-2
9.5 Timer 201219............................................................................................9-3
9.6 Timer 201220............................................................................................9-4
9.7 Timer 201233............................................................................................9-4
9.8 Timer 201234............................................................................................9-5
9.9 Timer 201235............................................................................................9-5
9.10 Timer 201237..........................................................................................9-6
9.11 Timer 201238..........................................................................................9-6
9.12 Timer 201239..........................................................................................9-7
9.13 Timer 201240..........................................................................................9-7
9.14 Timer 201241..........................................................................................9-8
9.15 Timer 201242..........................................................................................9-8
9.16 Timer 201243..........................................................................................9-9
9.17 Timer 201244..........................................................................................9-9
9.18 Timer 201245........................................................................................9-10
9.19 Timer 201246........................................................................................ 9-11
9.20 Timer 201248........................................................................................ 9-11
9.21 Timer 201249........................................................................................9-12

VI
9.22 Timer 201253 ....................................................................................... 9-12
9.23 Timer 201254 ....................................................................................... 9-13
9.24 Timer 201255 ....................................................................................... 9-13
9.25 Timer 201256 ....................................................................................... 9-14
9.26 Timer 201257 ....................................................................................... 9-14
9.27 Timer 201259 ....................................................................................... 9-15
9.28 Timer 201260 ....................................................................................... 9-15
9.29 Timer 201261 ....................................................................................... 9-16
9.30 Timer 201264 ....................................................................................... 9-16
9.31 Timer 201265 ....................................................................................... 9-17
9.32 Timer 201266 ....................................................................................... 9-18
9.33 Timer 201268 ....................................................................................... 9-18
9.34 Timer 201269 ....................................................................................... 9-19
9.35 Timer 201274 ....................................................................................... 9-19
9.36 Timer 201275 ....................................................................................... 9-20
9.37 Timer 201276 ....................................................................................... 9-20
9.38 Timer 201277 ....................................................................................... 9-21
9.39 Timer 201278 ....................................................................................... 9-21
9.40 Timer 201279 ....................................................................................... 9-22
9.41 Timer 201280 ....................................................................................... 9-22
9.42 Timer 201281 ....................................................................................... 9-23
9.43 Timer 201282 ....................................................................................... 9-23
9.44 Timer 201285 ....................................................................................... 9-24
9.45 Timer 201286 ....................................................................................... 9-25
9.46 Timer 201287 ....................................................................................... 9-25
9.47 Timer 201288 ....................................................................................... 9-26
9.48 Timer 201289 ....................................................................................... 9-26
9.49 Timer 201290 ....................................................................................... 9-27
9.50 Timer 201291 ....................................................................................... 9-27
9.51 Timer 201292 ....................................................................................... 9-28
9.52 Timer 201293 ....................................................................................... 9-28
9.53 Timer 201294 ....................................................................................... 9-29
VII
9.54 Timer 201295........................................................................................9-29
9.55 Timer 201296........................................................................................9-30
9.56 Timer 201297........................................................................................9-30
9.57 Timer 201298........................................................................................9-31
9.58 Timer 201299........................................................................................9-32
9.59 Timer 201300........................................................................................9-32
9.60 Timer 201301........................................................................................9-33
9.61 Timer 201302........................................................................................9-33
9.62 Timer 201303........................................................................................9-34
9.63 Timer 201304........................................................................................9-34
9.64 Timer 201305........................................................................................9-35
9.65 Timer 201306........................................................................................9-35
9.66 Timer 201307........................................................................................9-36
9.67 Timer 201308........................................................................................9-36
9.68 Timer 201314........................................................................................9-37
9.69 Timer 201316........................................................................................9-37
9.70 Timer 201317........................................................................................9-38
9.71 Timer 201318........................................................................................9-39
9.72 Timer 201319........................................................................................9-39
9.73 Timer 201320........................................................................................9-40
9.74 Timer 201321........................................................................................9-40
9.75 Timer 201322........................................................................................9-41
Chapter 10 Timers Related with G_TCAP Module...........................................10-1
10.1 Timer 201381........................................................................................10-1
10.2 Timer 201397........................................................................................10-1
10.3 Timer 201398........................................................................................10-2
10.4 Timer 201399........................................................................................10-2
10.5 Timer 201400........................................................................................10-3
10.6 Timer 201401........................................................................................10-4
10.7 Timer 201403........................................................................................10-4
10.8 Timer 201404........................................................................................10-5
10.9 Timer 201405........................................................................................10-5

VIII
10.10 Timer 201408 ..................................................................................... 10-6
10.11 Timer 201412 ..................................................................................... 10-6
10.12 Timer 201413 ..................................................................................... 10-7
10.13 Timer 201414 ..................................................................................... 10-7
10.14 Timer 201415 ..................................................................................... 10-8
10.15 Timer 201416 ..................................................................................... 10-8
10.16 Timer 201417 ..................................................................................... 10-9
10.17 Timer 201422 ..................................................................................... 10-9
10.18 Timer 201423 ....................................................................................10-10
10.19 Timer 201424 ....................................................................................10-11
10.20 Timer 201425 ....................................................................................10-11
10.21 Timer 201426 ....................................................................................10-12
10.22 Timer 201427 ....................................................................................10-12
10.23 Timer 201428 ....................................................................................10-13
10.24 Timer 201429 ....................................................................................10-13
10.25 Timer 201430 ....................................................................................10-14
10.26 Timer 201434 ....................................................................................10-14
10.27 Timer 201436 ....................................................................................10-15
10.28 Timer 201437 ....................................................................................10-16
10.29 Timer 201441 ....................................................................................10-16
10.30 Timer 201442 ....................................................................................10-17
10.31 Timer 201443 ....................................................................................10-17
10.32 Timer 201444 ....................................................................................10-18
10.33 Timer 201445 ....................................................................................10-18
10.34 Timer 201446 ....................................................................................10-19
10.35 Timer 201447 ....................................................................................10-19
10.36 Timer 201448 ....................................................................................10-20
10.37 Timer 201451 ....................................................................................10-20
10.38 Timer 201452 ....................................................................................10-21
10.39 Timer 201453 ....................................................................................10-22
10.40 Timer 201454 ....................................................................................10-22
10.41 Timer 201455 ....................................................................................10-23
IX
10.42 Timer 201456....................................................................................10-23
10.43 Timer 201457....................................................................................10-24
10.44 Timer 201458....................................................................................10-24
10.45 Timer 201459....................................................................................10-25
10.46 Timer 201460....................................................................................10-25
10.47 Timer 201461....................................................................................10-26
10.48 Timer 201462....................................................................................10-27
10.49 Timer 201463....................................................................................10-27
10.50 Timer 201464....................................................................................10-28
10.51 Timer 201467....................................................................................10-28
10.52 Timer 201469....................................................................................10-29
10.53 Timer 201471....................................................................................10-29
10.54 Timer 201474....................................................................................10-30
10.55 Timer 201476....................................................................................10-30
10.56 Timer 201477....................................................................................10-31
10.57 Timer 201478....................................................................................10-32
Chapter 11 Timers Related with G_GSMSSF Module...................................... 11-1
11.1 Timer 201611 ........................................................................................ 11-1
11.2 Timer 201612 ........................................................................................ 11-1
11.3 Timer 201613 ........................................................................................ 11-2
11.4 Timer 201614 ........................................................................................ 11-3
11.5 Timer 201615 ........................................................................................ 11-3
Chapter 12 Timers Related with G_BSSAP Module ........................................12-1
12.1 Timer 206112 ........................................................................................12-1
12.2 Timer 206113 ........................................................................................12-1
12.3 Timer 206114 ........................................................................................12-2
12.4 Timer 206115 ........................................................................................12-3
12.5 Timer 206116 ........................................................................................12-3
12.6 Timer 206119 ........................................................................................12-4
12.7 Timer 206120 ........................................................................................12-4
12.8 Timer 206121 ........................................................................................12-5
12.9 Timer 206122 ........................................................................................12-6

X
12.10 Timer 206123 ..................................................................................... 12-6
12.11 Timer 206124 ..................................................................................... 12-7
Chapter 13 Timers Related with G_RANAP Module ....................................... 13-1
13.1 Timer 206131 ....................................................................................... 13-1
13.2 Timer 206132 ....................................................................................... 13-2
13.3 Timer 206133 ....................................................................................... 13-2
13.4 Timer 206134 ....................................................................................... 13-3
13.5 Timer 206135 ....................................................................................... 13-3
13.6 Timer 206136 ....................................................................................... 13-4
13.7 Timer 206137 ....................................................................................... 13-5
13.8 Timer 206138 ....................................................................................... 13-5
13.9 Timer 206139 ....................................................................................... 13-6
13.10 Timer 206140 ..................................................................................... 13-7
13.11 Timer 206141 ..................................................................................... 13-7
13.12 Timer 206142 ..................................................................................... 13-8
13.13 Timer 206145 ..................................................................................... 13-8
13.14 Timer 206146 ..................................................................................... 13-9
13.15 Timer 206147 ....................................................................................13-10
13.16 Timer 206148 ....................................................................................13-10
13.17 Timer 206150 ....................................................................................13-11
13.18 Timer 206151 ....................................................................................13-12
13.19 Timer 206152 ....................................................................................13-12
13.20 Timer 206153 ....................................................................................13-13
13.21 Timer 206154 ....................................................................................13-14
Chapter 14 Timers Related with G_DH Module............................................... 14-1
14.1 Timer 206197 ....................................................................................... 14-1
14.2 Timer 206198 ....................................................................................... 14-1
14.3 Timer 206199 ....................................................................................... 14-2
14.4 Timer 206200 ....................................................................................... 14-3
Chapter 15 Timers Related with BICC Module................................................ 15-1
15.1 Timer 208402 ....................................................................................... 15-1
15.2 Timer 208403 ....................................................................................... 15-2
XI
15.3 Timer 208404 ........................................................................................15-3
15.4 Timer 208405 ........................................................................................15-4
15.5 Timer 208406 ........................................................................................15-5
15.6 Timer 208407 ........................................................................................15-6
15.7 Timer 208408 ........................................................................................15-7
15.8 Timer 208409 ........................................................................................15-8
15.9 Timer 208410 ........................................................................................15-9
15.10 Timer 208411 ....................................................................................15-10
15.11 Timer 208412 .................................................................................... 15-11
15.12 Timer 208413 ....................................................................................15-12
15.13 Timer 208414 ....................................................................................15-12
15.14 Timer 208415 ....................................................................................15-13
15.15 Timer 208416 ....................................................................................15-14
15.16 Timer 208417 ....................................................................................15-14
Index I

XII
About This Manual

Purpose

The purpose of writing this manual is to enable you to know the name, value range,
default duration, adjustment step length, flow description, and the function
description of each timer in the ZXWN MSCS system.
ZXWN MSCS MSC Server Timer Reference divides to two volumes:
z ZXWN MSCS MSC Server Timer Reference I
z ZXWN MSCS MSC Server Timer Reference
This manual is ZXWN MSCS MSC Server Timer Reference.

Intended Audience

This document is intended for:


z Engineers who have basic knowledge about mobile communications
z Engineers who have known the basic structure, and basic functions of ZXWN
MSCS
z Engineers who need to know the functions and value ranges of the timers of
ZXWN MSCS.

Prerequisite Skill and Knowledge

To use this document effectively, users should have a general understanding of


wireless telecommunications technology

What Is in This Manual

This manual contains the following chapters:

Chapter Summary
Chapter 1, Timers Related with G_MM Describes the detailed information of the timers
Module related with G_MM module.
Chapter 2, Timers Related with G_MCC Describes the detailed information of the timers
Module related with G_MCC module.
Chapter 3, Timers Related with Describes the detailed information of the timers
G_GMSC Module related with G_GMSC module.
Chapter 4, Timers Related with G_MCF Describes the detailed information of the timers
Module related with G_MCF module.
Chapter 5, Timers Related with Describes the detailed information of the timers
G_Common Module related with G_Common module.
Chapter 6, Timers Related with G_HO Describes the detailed information of the timers
Module related with G_HO module.
I
Chapter Summary
Chapter 7, Timers Related with Describes the detailed information of the timers
G_MSCMAP Module related with G_MSCMAP module.
Chapter 8, Timers Related with Describes the detailed information of the timers
G_VLRMAP Module related with G_VLRMAP module.
Chapter 9, Timers Related with G_TM Describes the detailed information of the timers
Module related with G_TM module.
Chapter 10, Timers Related with Describes the detailed information of the timers
G_TCAP Module related with G_TCAP module.
Chapter 11, Timers Related with Describes the detailed information of the timers
G_GSMSSF Module related with G_GSMSSF module.
Chapter 12, Timers Related with Describes the detailed information of the timers
G_BSSAP Module related with G_BSSAP module.
Chapter 13, Timers Related with Describes the detailed information of the timers
G_RANAP Module related with G_RANAP module.
Chapter 14, Timers Related with G_DH Describes the detailed information of the timers
Module related with G_DH module.
Chapter 15, Timers Related with BICC Describes the detailed information of the timers
Module related with BICC module.

Conventions

ZTE documents employ the following typographical conventions.

Typeface Meaning

Italics References to other Manuals and documents.

Quotes Links on screens.

Bold Menus, menu options, function names, input fields, radio button
names, check boxes, drop-down lists, dialog box names, window
names.

CAPS Keys on the keyboard and buttons on screens and company name.

Note: Provides additional information about a certain topic.

Checkpoint: Indicates that a particular step needs to be checked


before proceeding further.

Tip: Indicates a suggestion or hint to make things easier or more


productive for the reader.

II
Mouse operation conventions are listed as follows:

Typeface Meaning
Click Refers to clicking the primary mouse button (usually the left mouse
button) once.
Double-click Refers to quickly clicking the primary mouse button (usually the left
mouse button) twice.
Right-click Refers to clicking the secondary mouse button (usually the right mouse
button) once.

III
IV
Declaration of RoHS
Compliance

To minimize environmental impacts and take more responsibilities to the earth we


live on, this document shall serve as a formal declaration that ZXWN MSCS
manufactured by ZTE CORPORATION is in compliance with the Directive
2002/95/EC of the European Parliament - RoHS (Restriction of Hazardous
Substances) with respect to the following substances:
z Lead (Pb)
z Mercury (Hg)
z Cadmium (Cd)
z Hexavalent Chromium (Cr (VI))
z PolyBrominated Biphenyls (PBBs)
z PolyBrominated Diphenyl Ethers (PBDEs)

ZXWN MSCS manufactured by ZTE CORPORATION meets the requirements of


EU 2002/95/EC; however, some assemblies are customized to client specifications.
Addition of specialized, customer-specified materials or processes which do not
meet the requirements of EU 2002/95/EC may negate RoHS compliance of the
assembly. To guarantee compliance of the assembly, the need for compliant
product must be communicated to ZTE CORPORATION in written form.
This declaration is issued based on our current level of knowledge. Since
conditions of use are outside our control, ZTE CORPORATION makes no
warranties, express or implied, and assumes no liability in connection with the use
of this information.

I
II
Chapter 1
Timers Related with G_MM Module

1.1 Timer 201001


Macro Name of Timer

mcaT3210

Timer Name

G_MM Wait LUAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

The MS starts the location update request procedure by sending a location update
request message to the network, and this timer is started. When the MM module
receives various events stopping the location update procedure, it stops this timer.
When this timer expires, the MM module sends a location update reject message to
the MS.

1.2 Timer 201002


Macro Name of Timer

mcaT3255

Timer Name

1-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_MM Wait FollowOn

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

If any subsequent service exists after the location update is successful, this timer is
started. When the MM module receives a CM Service Req message from the MS,
it stops this timer. When this timer expires, the MM module releases the SCCP
connection.

1.3 Timer 201003


Macro Name of Timer

mcaT3250

Timer Name

G_MM Wait ReallTmsiCmp

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

When the MSC receives a TMSI re-allocation request from the VLR, it starts this
timer. When the MM module receives a TMSI Relocation Complete message from
the MS, it stops this timer. When this timer expires, the MM module continues the

1-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

normal flow.

1.4 Timer 201004


Macro Name of Timer

mcaT3260

Timer Name

G_MM Wait AuthAck

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

When the MSC sends an authentication request to the MS, it starts this timer. When
the MM module receives an authentication response message from the MS, it stops
this timer. When this timer expires, the MM module releases the SCCP connection.

1.5 Timer 201005


Macro Name of Timer

mcaT3270

Timer Name

G_MM Wait PvdIdAck

Value Range

0~86400000ms

Default Duration

12000ms

1-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

When the MSC sends an IDENTITY REQUEST message (requesting for the IMSI
and IMEI) to the MS, it starts this timer. When the MM module receives an
IDENTITY RESPONSE message from the MS, it stops this timer. When this timer
expires, the MM module releases the SCCP connection.

1.6 Timer 201006


Macro Name of Timer

mcaT3230

Timer Name

G_MM Wait ProcAccAck

Value Range

0~60000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

When the MSC receives a CM SERV REQ message from the MS, it starts this
timer. When the MM module sends a "CM SERV REJ" or "CM SERV ACC"
message to the MS, or after the cipher mode is set, the MM module stops this timer.
When this timer expires, the MM module rejects the service.

1.7 Timer 201007


Macro Name of Timer

mcaWatchMsInfoT

Timer Name
1-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

G_MM Watch MsInfo

Value Range

0~86400000ms

Default Duration

1000ms

Adjustment Step Length

1ms

Flow Description

When the active service is powered on or the standby service is switched to the
active one, the MM module starts this timer, and monitors the subscriber data table.
When this timer expires, the MM module scans the activated test data area. If there
is any data area meeting the conditions, the MM module sends an activation test
request.

1.8 Timer 201009


Macro Name of Timer

mcaResetT

Timer Name

G_MM Reset or Swap

Value Range

0~86400000ms

Default Duration

1000ms

Adjustment Step Length

1ms

Flow Description

When the MM module processes the Reset message from the RANAP/BSSAP
module, it starts this timer. When this timer expires, the MM module scans the

1-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

subscriber data table to find the corresponding subscriber whose hasResetFg flag is
set. The MM module releases all the services of this subscriber.

1.9 Timer 201010


Macro Name of Timer

mcaT3113

Timer Name

G_MM Wait PageRsp

Value Range

0~86400000ms

Default Duration

6000ms

Adjustment Step Length

1ms

Flow Description

When the MM module sends a paging (page/search) request to the MS, it starts this
timer. When the MM module receives a paging response message from the MS, it
stops this timer. When this timer expires, the MM module ends the processing if
multiple numbers of times of paging is not performed. Otherwise, the MM module
re-sends a paging message and re-sets the timer.

1.10 Timer 201011


Macro Name of Timer

mcaWaitSetupT

Timer Name

G_MM Wait Setup

Value Range

0~86400000ms

1-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

Default Duration

200000ms

Adjustment Step Length

1ms

Flow Description

Because a subscriber has been involved in another stable call, this call enters the
call waiting status. Then the MM module starts this timer. When the MM module
receives a setup message from the MS during the mobile call origination procedure,
or when the MM module receives a setup message from the CC module during the
mobile call termination procedure, it stops this timer. When this timer expires, the
MM module releases the service.

1.11 Timer 201012


Macro Name of Timer

mcaSST

Timer Name

G_MM Wait SS Completion

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

After the NI access is completed during the call-unrelated supplementary services


or the USSD service, the MM module starts this timer, and waits for the subsequent
service request. When the MM module receives a Register message from the MS or
a USSD request from the VLRMAP module, it stops this timer. When this timer
expires, the MM module releases the service.

1-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1.12 Timer 201013


Macro Name of Timer

mcaWaitCPAckT

Timer Name

G_MM Wait CPAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

When the MM module receives a RPAck message from the MSCAMP module
during the mobile call origination procedure, or when the MM module receives a
RPMTData message from the MSCAMP module during the mobile call termination
procedure, it starts this timer. When the MM module receives a CP-ACK message
from the MS, it stops this timer. When this timer expires, the MM module releases
the service.

1.13 Timer 201014


Macro Name of Timer

mcaWaitSMMOAckT

Timer Name

G_MM Wait SMMO Ack

Value Range

0~86400000ms

Default Duration

50000ms

1-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

Adjustment Step Length

1ms

Flow Description

After the MS sends a CPData message, the MM module starts this timer. When the
MM module receives a response message from the MSCAP module, it stops this
timer. When this timer expires, the MM module releases the service.

1.14 Timer 201015


Macro Name of Timer

mcaWaitSMMTAckT

Timer Name

G_MM Wait SMMT Ack Time

Value Range

0~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

After the MS returns a CPAck message, the MM module starts this timer. When the
MM module receives a CP-DATA message from the MS, it stops this timer. When
this timer expires, the MM module releases the service.

1.15 Timer 201016


Macro Name of Timer

mcaWaitSMST

Timer Name

G_MM Wait SMS

1-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

After the access is completed during the SMS-MO or SMS-MT procedure, the MM
module starts this timer. When the MM module receives a CP-DATA message from
the MS during the SMS-MO procedure, or when the MM module receives a short
message from the MSCMAP module during the SMS-MT procedure, it stops this
timer. When this timer expires, the MM module releases the service.

1.16 Timer 201018


Macro Name of Timer

mcaWaitRelResT

Timer Name

G_MM Slave Wait Master Rel

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

When the active server is switched to the standby one, the MM module starts this
timer. When MM module scans the subscriber data table, it stops this timer.

1-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

1.17 Timer 201020


Macro Name of Timer

mcaWaitLCST

Timer Name

G_MM Wait LCS

Value Range

0~86400000ms

Default Duration

180000ms

Adjustment Step Length

1ms

Flow Description

After the access is completed during the LCSMO or LCSMT procedure, the MM
module starts this timer. When the location is completed or stooped by the VLRMAP
module, the MM module stops this timer. If this timer expires, the MM module
releases the service.

1.18 Timer 201021


Macro Name of Timer

mcaUSSDT

Timer Name

G_MM Wait USSD

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

During the USSDMO or USSDMT service, after the MM module receives a service
request, it starts this timer to avoid the long-time suspension of the data area (which
is caused by too long duration of the USSD service request timer). When the USSD
service ends or the VLRMAP/subscriber terminates the USSD service, the MM
module stops this timer. If this timer expires, the MM module releases the USSD
service.

1.19 Timer 201022


Macro Name of Timer

mcaWaitMCCRelReq

Timer Name

G_MM WaitMCCRelReq

Value Range

0~86400000ms

Default Duration

15700ms

Adjustment Step Length

1ms

Flow Description

After receiving a Setup message, the MM module starts this timer. After receiving a
message of releasing the MM data area from the CC module, the MM module stops
this timer. If this timer expires, the MM module releases the USSD service.

1.20 Timer 201023


Macro Name of Timer

mcaWaitMChangeOverT

Timer Name

1-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

G_MM WaitMChangeOver

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After receiving a request for switching the standby server to the active one, the MM
module starts this timer. After receiving a message of the standby server being
successfully switched to the active one, the MM module stops this timer. If this timer
expires, the original standby server is forcibly switched to the active one.

1.21 Timer 201024


Macro Name of Timer

mcaScanFreeCtrlT

Timer Name

G_MM ScanFreeCtrl

Value Range

0~86400000ms

Default Duration

18000000ms

Adjustment Step Length

1ms

Flow Description

After the active/standby servers are powered on or switched, the MM starts this
timer, and starts to scan the msInfo, ccInfo, and MM data areas. If the MM module

1-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

normally stops this timer, it makes the unused tables not in the list of idle tables be
idle.

1.22 Timer 201025


Macro Name of Timer

mcaScanFreeT

Timer Name

G_MM ScanFree

Value Range

0~86400000ms

Default Duration

1800000ms

Adjustment Step Length

1ms

Flow Description

This timer is for starting to scan the msInfo, ccInfo, and other data areas. If the MM
module normally stops this timer, it makes the unused tables not in the list of idle
tables be idle.

1.23 Timer 201026


Macro Name of Timer

mcaT3212

Timer Name

G_MM T3212

Value Range

0~86400000ms

Default Duration

3600000ms
1-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 1 Timers Related with G_MM Module

Adjustment Step Length

1ms

Flow Description

This timer is for setting Phase1 of load reallocation.

1.24 Timer 201027


Macro Name of Timer

mcaPSIT

Timer Name

G_MM PSIT

Value Range

0~6000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

After the PSI service ends, if the A/Iu connection is not released, the MM module
starts this timer. It is recommended to keep the A/Iu-interface connection for a short
period of time (such as 2s) after the PSI paging procedure. Thus, the paging
procedure need not be initiated in the subsequent call procedure to avoid conflicts
between different procedures. If the MM module performs settings to keep the
connection after the PSI procedure, it stops this timer. If this timer expires, the MM
module keeps the connection if any new service is accessed; otherwise, the MM
module releases the connection.

1-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


1-16

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2
Timers Related with G_MCC Module

2.1 Timer 201031


Macro Name of Timer

mccT301

Timer Name

G_MCC T301

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

1. The called side receives an ALERT message from the wireless side.
2. The MCC module starts this timer, and waits for a CONNECT message.
3. If this timer expires, the MCC module immediately releases the call.

2.2 Timer 201032


Macro Name of Timer

mccT303

Timer Name

G_MCC T303
2-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. During a call, the called side sends a SETUP message to the MS.
2. The MCC module starts this timer, and waits for a CallConfirm message
from the MS.
3. If this timer expires, the MCC module releases the call.

2.3 Timer 201033


Macro Name of Timer

mccT305

Timer Name

G_MCC T305

Value Range

0~86400000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

1. After timeout occurs when the network side waits for a message from
the MS, the network side releases the call.
2. The network side sends a Disconnect message to the MS.
3. The network side starts this timer, and waits for a response message
from the MS.

2-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.4 Timer 201034


Macro Name of Timer

mccT306

Timer Name

G_MCC T306

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. During the call release procedure, the network side sends a Disconnect
message to the MS.
2. The network side starts this timer, and waits for a Release message
from the MS.
3. If this timer expires, the network side directly sends a Release message
to the MS.

2.5 Timer 201035


Macro Name of Timer

mccT308

Timer Name

G_MCC T308

Value Range

0~86400000ms

Default Duration

5000ms

2-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

1. During the call release procedure, the network side sends a Release
message to the MS.
2. The network side starts this timer, and waits for a Release complete
message from the MS.
3. On the first expiry of this timer, the network side resends the Release
message to the MS, and restarts this timer.
4. On the second expiry of this timer, the network side directly releases the
call-related resources.

2.6 Timer 201036


Macro Name of Timer

mccT310

Timer Name

G_MCC T310

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. After a call enters the stable status, the MCC module at the called side
receives a CallConfirm message.
2. The MCC module starts this timer, and waits for an ALERT message
from the MS.

2-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.7 Timer 201037


Macro Name of Timer

mccT313

Timer Name

G_MCC T313

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. During a call, the MCC module at the network side receives a Connect
message from the MS.
2. The MCC module starts this timer, and waits for a ConnectAck message
from the MS.
3. If this timer expires, the MCC module releases the call.

2.8 Timer 201038


Macro Name of Timer

mccT322

Timer Name

G_MCC T322

Value Range

0~86400000ms

Default Duration

30000ms

2-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

1. During an activation test or call reestablishment procedure, the MCC


module sends a status request message to the MS.
2. The MCC module starts this timer, and waits for a response from the
MS.
3. If this timer expires, the MCC module releases the call.

2.9 Timer 201039


Macro Name of Timer

mccT323

Timer Name

G_MCC T323

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. After sending a bearer information modification notification of the access


side to the MS, the MCC module starts this timer, and waits for a
response from the MS.
2. If this timer expires, the MCC module releases the call.

2.10 Timer 201040


Macro Name of Timer

mccOpWaitCmpCallT

2-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Timer Name

G_MCC OpWaitCmpCall

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

1. After sending a SIFPC outgoing call request to the VLR, the OCH at the
calling side starts this timer, and waits for a CompleteCall message from
the VLR.
2. If this timer expires, the MCC module releases the call.

2.11 Timer 201041


Macro Name of Timer

mccOpWaitTpAckT

Timer Name

G_MCC OpWaitTpAck

Description

This timer is not used at present.

2.12 Timer 201042


Macro Name of Timer

mccOpWaitTpAcmT

Timer Name

G_MCC OpWaitTpAcm

Value Range
2-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. The calling side starts this timer, and waits for an Alerting message from
the called side.
2. If this timer expires, the calling side releases the call.
3. If the calling side receives an Alerting, answer, or release message from
the called side, it stops this timer.

2.13 Timer 201043


Macro Name of Timer

mccOpWaitTpAnmT

Timer Name

G_MCC OpWaitTpAnm

Value Range

0~86400000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

1. The calling side starts this timer, and waits for an ANM message from
the called side.
2. If this timer expires, the calling side releases the call.
3. If the calling side receives an ANM or Release message from the called
side, it stops this timer.

2-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.14 Timer 201044


Macro Name of Timer

mccTpWaitCmpCallT

Timer Name

G_MCC TpWaitCmpCall

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. After sending a SIFIC incoming call request to the VLR, the MCC
module at the called side starts this timer, and waits for a CompleteCall
message from the VLR.
2. If this timer expires, the MCC module releases the call.

2.15 Timer 201045


Macro Name of Timer

mccTpWaitFwdAcmT

Timer Name

G_MCC TpWaitFwdAcm

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

2-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

1. The called side starts this timer, and waits for an ALERT message from
the forwarded-to side.
2. If this timer expires, the called side releases the call.
3. If the called side receives an alert, answer, or release message from the
forwarded-to side, it stops this timer.

2.16 Timer 201046


Macro Name of Timer

mccTpWaitFwdAnmT

Timer Name

G_MCC TpWaitFwdAnmEvent

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

1. The called side starts this timer, and waits for an ANM message from the
forwarded-to side.
2. If this timer expires, the called side releases the call.
3. If the called side receives an answer or release message, it stops this
timer.

2.17 Timer 201047


Macro Name of Timer

mccTpNryT

2-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Timer Name

G_MCC TpNry

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

When the called side starts this timer, and waits for a response message from the
MS, and if the subscriber is a CAMEL subscriber and "O-no-response event" is
configured on the SCP, the following method to determine the duration of
no-response timer can be used. If the SCP does not send the "Application Timer"
parameter, the MSC should use the user-defined default duration of the response
timer, which equals 5s subtracted from the duration of timer mccTpNryT. If the SCP
sends the "Application Timer" parameter that exceeds the duration of timer
mccTpNryT, the MSC also should use the user-defined default duration of the
response timer. Otherwise, the MSC uses the duration of the Application Timer
sent by the SCP.

2.18 Timer 201048


Macro Name of Timer

mccTpWaitAcceptT

Timer Name

G_MCC TpWaitAccept

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length


2-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

1. During a call waiting procedure, the VLR does not return a no-response
message.
2. The MCC module starts this timer, and waits for the call to be accessed.
3. If this timer expires, the MCC module releases the call.

2.19 Timer 201049


Macro Name of Timer

mccTpWaitReconnResultT

Timer Name

G_MCC TpWaitReconnect

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. In case of call re-connection, the MCC module sends a re-connection


request to the VLR.
2. The MCC module starts this timer, and waits for a response from the
VLR.
3. If this timer expires, the MCC module releases the call.

2.20 Timer 201050


Macro Name of Timer

mccPeriodBillT

2-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Timer Name

G_MCC PeriodBill

Value Range

0~86400000ms

Default Duration

1800000ms

Adjustment Step Length

1ms

Flow Description

1. After receiving an ANM message, the called side starts this timer.
2. If this timer expires, a CDR is generated. Then this timer is restarted.
3. If this timer expires, another CDR is generated. This cycle is repeated.

2.21 Timer 201051


Macro Name of Timer

mccWaitStopToneT

Timer Name

G_MCC WaitStopTone

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module receives a playtone response message.


2. The MCC module starts this timer, and waits for a tone-play stopping
action from the H248 module.
2-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

3. After receiving a tone-play stopping response (RSP), the MCC module


stops this timer.

2.22 Timer 201052


Macro Name of Timer

mccRabAssRspT

Timer Name

G_MCC WaitRabRsp

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. During a 3G call, the MSC sends a "RAB ASSIGNMENT REQUEST"


message to request the RNC to establish the RAB.
2. The MSC starts this timer, and waits for a "RAB ASSIGNMENT
RESPONSE" message from the RNC.
3. If this timer expires, the MSC releases the call.

2.23 Timer 201053


Macro Name of Timer

mccRabAssQueT

Timer Name

G_MCC WaitRabQue

Value Range

0~86400000ms

2-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. During a 3G call, the MSC sends a "RAB ASSIGNMENT REQUEST"


message to the RNC.
2. The RNC returns a "RAB ASSIGNMENT RESPONSE" message
carrying the queuing indicator.
3. The MSC stops timer mccRabAssRspT, and starts timer
mccRabAssQueT.
4. The MSC waits for a "RAB ASSIGNMENT RESPONSE" message from
the RNC again.

2.24 Timer 201054


Macro Name of Timer

mccRabAssRelT

Timer Name

G_MCC WaitRabRel

Value Range

0~86400000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

1. During a 3G call, the MSC sends a "RAB ASSIGNMENT REL


REQUEST" message (mcRabAssRelReqEvent) to request the RNC to
release the RAB.

2-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

2. The MSC starts this timer, and waits for a "RAB ASSIGNMENT
RESPONSE" message from the RNC.
3. After receiving an mcRabAssRelRspEvent message from the RCN, the
MSC stops this timer.

2.25 Timer 201055


Macro Name of Timer

mccHoldSwapT

Timer Name

G_MCC HoldSwap

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

1. In case of multiple calls, when the call in the holding status and that in
the conversation status are swapped, this timer is started.
2. When this time expires, the MCC module rejects the swap request.

2.26 Timer 201056


Macro Name of Timer

mccDtmfGuardT

Timer Name

G_MCC DtmfGuard

Value Range

0~86400000ms

2-16

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Default Duration

300ms

Adjustment Step Length

1ms

Flow Description

1. After receiving a DTMF start message from the MS, the MCC module at
the network side starts this timer, and waits for a DTMF signal stopping
message from the MS.
2. After receiving a DTMF signal stopping message from the MS, the MCC
module at the network side stops this timer.
3. The MCC module at the network side sends an mcL3StopDtmfAckEvent
message to the MS.

2.27 Timer 201057


Macro Name of Timer

mccAliveTestT

Timer Name

G_MCC AliveTest

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. During an activation test procedure, the MCC module sends an


activation test request to the call module.
2. The MCC module starts this timer, and waits for an activation test
response.

2-17

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

3. If this timer expires, the MCC module releases the call.

2.28 Timer 201058


Macro Name of Timer

mccWaitAoCcAckT

Timer Name

G_MCC WaitAoCCAck

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

1. The called side receives an mcL3ConnectEvent message.


2. The billing procedure is started (with the precondition that the AOC
supplementary service is subscribed).
3. The called side starts this timer, and waits for an AOC billing response
message from the MS.
4. After receiving an AOC billing response message, the called side stops
this timer.
5. If this timer expires, the called side releases the call.

2.29 Timer 201059


Macro Name of Timer

mccApplyWarnT

Timer Name

G_MCC ApplyWarning

Value Range

2-18

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

0~86400000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

1. During the intelligent service, when the MCC module plays a warning
tone, it starts this timer.
2. If this timer expires, the MCC module performs the corresponding
processing according to the play status of the returned warning tone.
Four played warning statuses exist as follows:
noWarning
playWarning
pauseWarning
waitH248Rsp.

2.30 Timer 201060


Macro Name of Timer

mccStartBearerEst

Timer Name

G_MCC StartBearerEst

Value Range

0~86400000ms

Default Duration

180000ms

Adjustment Step Length

1ms

Flow Description

1. During a tone play procedure, the MCC module needs to apply for a
terminal.
2-19

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

2. The MCC module starts this timer, and waits for a response from the
H248 module after sending a terminal establishment request.
3. If the MCC module has not received the response from the H248
module before this timer expires, it releases the call.

2.31 Timer 201061


Macro Name of Timer

mccWaitBearerRsp

Timer Name

G_MCC WaitBearerRsp

Value Range

0~86400000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

1. During the interaction with the MGW, the MCC module sends a terminal
establishment or terminal attribute modification request to the MGW.
2. The MCC module starts this timer, and waits for a response from the
H248 module at the MGW side.
3. If this timer expires, the MCC module releases the call.

2.32 Timer 201062


Macro Name of Timer

mccWaitCodecNegoRsp

Timer Name

G_MCC WaitCodecNegoRsp

Value Range

2-20

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module starts the codec negotiation procedure as required.


2. The MCC module starts this timer, and waits for a codec negotiation
response.
3. If the MCC module receives a codec negotiation response, the codec
negotiation procedure is successful.
4. If this timer expires, the MCC module restores Codec backed up in the
MCC process data area, and releases the call.

2.33 Timer 201063


Macro Name of Timer

mccWaitCodecModRsp

Timer Name

G_MCC WaitCodecModRsp

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module starts the codec modification procedure as required.


2. The MCC module starts this timer, and waits for a codec modification
response.

2-21

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

3. If the MCC module receives a codec modification response, the codec


modification procedure is successful.
4. If this timer expires, the MCC module restores Codec backed up in the
MCC process data area, and releases the call.

2.34 Timer 201064


Macro Name of Timer

mccWaitTunnelInfo

Timer Name

G_MCC WaitTunnelInfo

Description

This timer is not used at present.

2.35 Timer 201065


Macro Name of Timer

mccWaitH248Rsp

Timer Name

G_MCC WaitH248Rsp

Value Range

0~86400000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

1. The MCC module sends a message of modifying the terminal bearer


capability.
2. The MCC module starts this timer, and waits for a response from the
H248 module.
2-22

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

3. If the MCC module has received a response, it stops this timer.


4. If this timer expires, the MCC module performs H248 failure processing.

2.36 Timer 201066


Macro Name of Timer

mccScanTimeT

Timer Name

G_MCC ScanTime

Flow Description

This timer is not used at present.

2.37 Timer 201067


Macro Name of Timer

mcMpPoweroffT

Timer Name

G_MCC MpPoweroff

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. The MP is successfully restarted.


2. The MCC module starts this timer, and MCC module releases calls in
batches.
3. After releasing mccBatchRelLimit_M calls, the MCC module doest not
release all the calls successfully.

2-23

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

4. If this timer expires, the MCC module restarts this timer, and continues
to releases the rest calls.

2.38 Timer 201068


Macro Name of Timer

mccGetCICRspT

Timer Name

G_MCC GetCICRsp

Value Range

0~86400000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

1. In case of 2G access, when the MSCS requests for the terrestrial circuit
resources to the BSC, it starts this timer, and waits for a response.
2. In case of 2B or 3C model with the TDM bearer between MGWs, the
MSCS starts this timer, and waits for the CIC from the database.
3. If this timer expires, the MSCS performs failure processing.

2.39 Timer 201069


Macro Name of Timer

mccWaitBearerEst

Timer Name

G_MCC WaitBearerEst

Value Range

0~86400000ms

2-24

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. When the MCC module needs to monitor the bearer establishment, it


starts this timer, and periodically monitors the bearer establishment.
2. After receiving a response from the wireless side, the MCC module
stops this timer, and sets the flag of the network bearer-connection
being successfully established.

2.40 Timer 201070


Macro Name of Timer

mccleg1OnlyT

Timer Name

G_MCC Leg1Only

Description

This timer is not used for the G-MCC module.

2.41 Timer 201103


Macro Name of Timer

mccDDCDelayIndT

Timer Name

G_MCC DDCDelayInd

Value Range

0~86400000ms

Default Duration

12000ms

2-25

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

During a Brazil DDC call, if it is required to play tones to the calling party and the
called party, this time is started after the tone play processing is completed. Within
the timer duration, if the called party hangs up, the call ends, with the release cause
value as 21 (Q850CallRefused), and the local office normally generates a CDR. The
CDR should contain the DDC flag. This call is not charged in the accounting system.
After this timer ends, the calling party and the called party enter the conversation
phase. After this, whether the calling party or the called party hangs up, the call
ends, with the release cause value as 16 (Q850No7NormalClearing), and the local
office normally generates a CDR. The CDR should contain the DDC flag. The called
party is charged in the accounting system, with the timer duration deducted from the
call duration.

2.42 Timer 201104


Macro Name of Timer

mccDDCToneCmpIndT

Timer Name

G_MCC DDCToneCmpInd

Description

This timer is not used at present.

2.43 Timer 201105


Macro Name of Timer

mccDDCAvoidCHT

Timer Name

G_MCC DDCAvoidCH

Description

This timer is not used at present.

2-26

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.44 Timer 201106


Macro Name of Timer

mccCallPeriodTrafficT

Timer Name

G_MCC CallPeriodTraffic

Value Range

60000~300000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the interval for periodically reporting the traffic statistics.
1. After this timer expires, the MCC module periodically reports the traffic
statistics.
2. After releasing the call, the MCC module stops this timer.

2.45 Timer 201107


Macro Name of Timer

mccSendToneRepeatT

Timer Name

G_MCC ToneRepeatT

Value Range

0~86400000ms

Default Duration

540000ms

Adjustment Step Length

2-27

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

1. The local-office-originated service is analyzed to the tone-play service


with the called number being analyzed, and there is no restriction on the
tone-play duration.
2. The MCC module plays the tone to the calling party. Because the
maximum tone-play duration supported by the MGW is about 10
minutes at present, the MCC module starts this timer after receiving the
first tone-play response message from the MGW. Thus no restriction on
the tone-play duration is implemented.
3. The MCC module sends a tone-play message to the MGW every the
timer duration.

2.46 Timer 201134


Macro Name of Timer

IntraBSCHandover

Timer Name

G_MCC mccIntraHo

Value Range

3000~30000ms

Default Duration

6000ms

Adjustment Step Length

1ms

Flow Description

1. The calling and called parties receive an internal handover detection


message from the BSC at the wireless side.
2. The MCC module starts this timer, and waits for an internal handover
result from the BSC.
3. If the MCC module has not received an internal handover result before
this timer expires, it performs failure processing.

2-28

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.47 Timer 201136


Macro Name of Timer

mccT331

Timer Name

G_MCC T331

Value Range

5000~30000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. After sending a CM Service Prompt message, the network starts this


timer, and waits for a Start CC message.
2. If the network has not received a Start CC message before this timer
expires, it performs failure processing.

2.48 Timer 201137


Macro Name of Timer

mccT333

Timer Name

G_MCC T333

Value Range

5000~30000ms

Default Duration

20000ms

Adjustment Step Length

2-29

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

1. This timer is timer T333 for the CCBS function. After sending a "CC
Establishment" message, the MCC module at the network side starts
this timer.
2. The MCC module waits for a "CC Establishment Confirm" message.
3. If the MCC module has not received a CC Establishment Confirm
message before this timer expires, it performs response failure
processing.

2.49 Timer 201138


Macro Name of Timer

mccCCBST1

Timer Name

G_MCC CCBST1

Value Range

15000~60000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

1. This timer is timer T1 for the CCBS function. When the network sends a
"DISCONNECT" message to trigger the CCBS function, the MCC
module starts this timer.
2. The MCC module waits for a RELEASE message from the monitored
MS.
3. If the MCC module has received a RELEASE message from the CC
module due to tone-play failure or other internal failure, it stops timer
T306. Then it sends the RELEASE message to the MS, and stops timer
CCBST1.

2-30

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.50 Timer 201139


Macro Name of Timer

mccCCBST4

Timer Name

G_MCC CCBST4

Value Range

20000~30000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. This timer is timer T4 for the CCBS function. When the network sends a
RECALL message to the MS, it starts this timer.
2. After starting this timer, the network monitors the RECALL procedure.
3. After receiving a SETUP message, the network stops this timer.

2.51 Timer 201140


Macro Name of Timer

mccWaitStopTone2T

Timer Name

G_MCC WaitStopTone2

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

2-31

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

1. After a call drop occurs at the call access side, the MCC module judges
that License Function Set - Whether to play announcement after
temporarily disconnection is Yes.
2. The MCC module plays the notification tone to the peer end instead of
immediately releasing the peer end. The MCC module starts this timer,
and monitors the tone play being completed.
3. After this timer expires, the MCC module stops playing the tone to the
peer end.

2.52 Timer 201159


Macro Name of Timer

mccCCBST10

Timer Name

G_MCC CCBST10

Value Range

20000~30000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

1. This timer is timer T10 for the CCBS function. When the network sends
a RECALL message to the MS, it starts this timer.
2. After starting this timer, the network monitors the RECALL procedure.
3. After receiving a SETUP message from the MS, the network stops this
timer.

2-32

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

2.53 Timer 201679


Macro Name of Timer

mccWaitPBRTT

Timer Name

G_MCC Wait PBRTT

Value Range

0~86400000ms

Default Duration

3000ms

Adjustment Step Length

1ms

Flow Description

1. In case of the PBRT being triggered, the MCC module starts this timer,
and waits for a response.
2. When the MCC module stops the PBRT service, it stops this timer.

2.54 Timer 201681


Macro Name of Timer

mccIstReponseTimer

Timer Name

G_MCC IstReponseTimer

Value Range

0~86400000ms

Default Duration

32000ms

Adjustment Step Length

1ms
2-33

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

1. After sending an IST ALERT request to the MSCMAP module, the


MCC module starts this timer.
2. After receiving an IST ALERT message from the MSCMAP module,
the MCC module stops this timer.

2.55 Timer 201682


Macro Name of Timer

mccPositionLowDelayTimer

Timer Name

G_MCC PositionLowDelayTimer

Value Range

1000~30000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

BSC MSC

1
SETUP

2
CALL PROCEEDING

3
PERFORM LOCATION REQUEST

4
PERFORM LOCATION RESPONSE

5
IAM

2-34

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

RNC MSC

1
SETUP

2
CALL PROCEEDING

3
LOCATION REPORTING CONTROL

4
LOCATION REPORT

5
IAM

1. The MSC receives a SETUP message (indicating the call is an E911 call)
from the BSC/RNC.
2. The MSC sends a CALL PROCEEDING message to the BSC/RNC.
3. After sending a location request message (PERFORM LOCATION
REQUEST message to the BSC, and LOCATION REPORTING
CONTROL message to the RNC) to the BSC/RNC, the MSC starts this
timer.
4. After receiving a location response message (PERFORM LOCATION
RESPONSE message from the BSC, and LOCATION REPORT
message from the RNC) from the BSC/RNC, the MSC stops this timer.
5. In case of Phase II Push mode, the MSC directly sends an IAM
message to another MSC. In case of Phase II Pull GMLC routing mode
(accurate locating), the MSC reports the location of the subscriber to the
GMLC before sending an IAM message to another MSC.
6. If this timer expires, the call continues.

2.56 Timer 201683


Macro Name of Timer

mccPositionDelayTolerTimer

Timer Name

G_MCC PositionDelayTolerTimer

Value Range

1000~300000ms
2-35

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

During an E911 call adopting the Phase II Pull MSC routing mode, the MSC starts
this timer. The call flow is shown in the figures below.

BSC MSC

1
SETUP

2
CALL PROCEEDING

3
PERFORM LOCATION REQUEST
4
IAM
5
PERFORM LOCATION RESPONSE

RNC MSC

1
SETUP

2
CALL PROCEEDING

3
LOCATION REPORTING CONTROL
4
IAM
5
LOCATION REPORT

1. The MSC receives a SETUP message (indicating the call is an E911 call)
from the BSC/RNC.
2. The MSC sends a CALL PROCEEDING message to the BSC/RNC.
2-36

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

3. After sending a location request message (PERFORM LOCATION


REQUEST message to the BSC, and LOCATION REPORTING
CONTROL message to the RNC) to the BSC/RNC, the MSC starts this
timer.
4. The MSC directly sends an IAM message to another MSC without
waiting for a location response message.
5. After receiving a location response message (PERFORM LOCATION
RESPONSE message from the BSC, and LOCATION REPORT
message from the RNC) from the BSC/RNC, the MSC stops this timer. If
this timer expires, the MSC will not report to the GMLC.

2.57 Timer 201684


Macro Name of Timer

mccWaitGMLCRouteTimer

Timer Name

G_MCC WaitGMLCRouteTimer

Value Range

1000~30000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During an E911 call adopting the Phase II Pull GMLC routing mode (accurate
locating or inaccurate locating), the MSC starts this timer. The call flow is shown in
the figure below.

2-37

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1. The MSC receives a SETUP message (indicating the call is an E911 call)
from the BSC/RNC.
2. The MSC sends a CALL PROCEEDING message to the BSC/RNC.
3. The MSC sends a location request message (PERFORM LOCATION
REQUEST message to the BSC, and LOCATION REPORTING
CONTROL message to the RNC) to the BSC/RNC. In case of
inaccurate locating, this step is skipped.
4. The MSC receives a location response message (PERFORM
LOCATION RESPONSE message from the BSC, and LOCATION
REPORT message from the RNC) from the BSC/RNC. In case of
inaccurate locating, this step is skipped.
5. After sending a MAP_SUB_LOCATION_REPORT message to the
GMLC, the MSC starts this timer, and waits for a response message.

2-38

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 2 Timers Related with G_MCC Module

6. After receiving a MAP_SUB_LOCATION_REPORT_RSP message from


the GMLC, the MSC stops this timer. If this timer expires, the MSC
continues processing the call.
7. The MSC sends an IAM message to another MSC.

2.58 Timer 201762


Macro Name of Timer

mcc23205StartBearerEst

Timer Name

G_MCC 23205StartBearerEst

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

1. When the BICC incoming call lands, if the BICC module does not
establish the calling bearer, and the security variable "Call control
parameters -> Whether to support Start Bearer Timer While Paging at
VMSC" is "Yes", the MCC module starts this timer.
2. After this timer expires, the MCC module tells the BICC module to
establish the calling bearer.

2-39

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


2-40

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3
Timers Related with G_GMSC
Module

3.1 Timer 201071


Macro Name of Timer

mcgWtRoutRspT

Timer Name

G_GMSC Wait RoutRsp

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

3-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

This timer is for the routing from the GMSC to the HLR. After sending a routing
request, the GMSC module waits for a routing response.

3.2 Timer 201072


Macro Name of Timer

mcgWtTpAckT

Timer Name

G_GMSC Wait TpAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

3-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

When the roaming number of the GMSC module is outgoing, the GMSC module
starts this timer, and waits for a TpInfo message from the peer end. After this timer
expires, the GMSC module releases the call.

3.3 Timer 201073


Macro Name of Timer

mcgWtAcmT

Timer Name

G_GMSC Wait Acm

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

3-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

After sending a SETUP message, the GMSC module waits for an Alerting message
from the called side. After this timer expires, the GMSC module releases the call.

3.4 Timer 201074


Macro Name of Timer

mcgWtAnmT

Timer Name

G_GMSC Wait Anm

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

3-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

The GMSC module starts this timer, and waits for a StartConvEvent message from
the peer end. After this timer expires, the GMSC module releases the call.

3.5 Timer 201076


Macro Name of Timer

mcgWtOpBearEstT

Timer Name

G_GMSC Wait OpBearEst

Value Range
0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

3-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

The GMSC module starts this timer, and waits for an OPConnectedEvent (bearer
establishment of the calling side) message. After this timer expires, the GMSC
module releases the call.

3.6 Timer 201077


Macro Name of Timer

mcgWtH248RspT

Timer Name

G_GMSC Wait H248Rsp

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

3-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

3.7 Timer 201078


Macro Name of Timer

mcgWtAliveTstAckT

Timer Name

G_GMSC Wait AliveTstAck

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

3.8 Timer 201079


Macro Name of Timer

mcgWtAfiAckT
3-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Timer Name

G_GMSC Wait AfiAck

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

3.9 Timer 201080


Macro Name of Timer

mcgWtPlayToneT

Timer Name

G_GMSC Wait PlayTone

Value Range

0~86400000ms

Default Duration

10000ms

3-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

Adjustment Step Length

1ms

Flow Description

3.10 Timer 201082


Macro Name of Timer

mcgPBRTWtAcmT

Timer Name

G_GMSC PBRT Wait Acm

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

GMSC PBRT MCC

Alerting
SetUp
T-
201082
PBRT Alerting

3-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

3.11 Timer 201083


Macro Name of Timer

mcgPBRTWtTpAckT

Timer Name

G_GMSC PBRT Wait TpAck

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

3.12 Timer 201084


Macro Name of Timer

mcgWaitBearerRspT

Timer Name

G_GMSC Wait BearerRsp

Value Range

0~86400000ms

3-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

3.13 Timer 201085


Macro Name of Timer

mcgPBRTWtClearT

Timer Name

G_GMSC PBRT Wait Clear

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

3-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

3.14 Timer 201086


Macro Name of Timer

mcgWtVlrModuleNoT

Timer Name

G_GMSC Wait VlrModuleNo

Value Range

0~86400000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

3-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 3 Timers Related with G_GMSC Module

3.15 Timer 201087


Macro Name of Timer

mcgPBRTWtStopOKT

Timer Name

G_GMSC PBRT Wait StopOK

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

3.16 Timer 201088


Macro Name of Timer

mcgStartBearerEst

Timer Name

G_GMSC StartBearerEst

Value Range

3-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

During a BICC incoming call, if the BICC module has not established the calling
bearer before the GMSC module sends a routing request, and the security variable
"Call control parameters -> Whether to support Start Bearer Timer While Paging at
VMSC" is "Yes", the GMSC module starts this timer. When this timer expires, the
GMSC module tells the BICC module to establish the calling bearer.

3.17 Timer 201089


Macro Name of Timer

mcgIstReponseTimer

Timer Name

G_GMSC IstReponseTimer

Value Range

0~86400000ms

Default Duration

32000ms

Adjustment Step Length

1ms

Flow Description

After sending an "IST ALERT" request, the GMSC module starts this timer. After
receiving an "IST ALERT" response, the GMSC module stops this timer.

3-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 4
Timers Related with G_MCF Module

4.1 Timer 201092


Macro Name of Timer

mcfWaitTpAckT

Timer Name

G_MCF Wait TpAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

4-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

4.2 Timer 201093


Macro Name of Timer

mcfWaitAcmT

Timer Name

G_MCF Wait Acm

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

MCF GMSC

SetUp

T-
201093

Alerting

4.3 Timer 201094


Macro Name of Timer

mcfWaitAnmT

Timer Name

G_MCF Wait Anm

4-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 4 Timers Related with G_MCF Module

Value Range

0~86400000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

4.4 Timer 201095


Macro Name of Timer
mcfWaitClearT

Timer Name

G_MCF Wait Clear

Value Range

0~86400000ms

Default Duration

1800000ms

Adjustment Step Length

1ms

4-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

This timer specifies the interval for periodically generating CDRs. The default
duration of a periodical CDR is 30 minutes, which can be modified on the OMM
Client.

4.5 Timer 201096


Macro Name of Timer

mcfAliveTstAckT

Timer Name

G_MCF AliveTstAck

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

Before generating CDRs, the MCF module performs an activation test. Then the
MCF module starts this timer, and waits for an activation test response message
from the peer end. If the activation test fails, a 10s CDR is generated.

4.6 Timer 201097


Macro Name of Timer

mcfAfiAckT

Timer Name

G_MCF Afi Ack

Value Range

0~86400000ms

4-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 4 Timers Related with G_MCF Module

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

After sending an AFIReq message to the calling process, the MCF module starts
this timer, and waits for an AfiAckEvent message from the calling process.

4.7 Timer 201102


Macro Name of Timer

mcfWaitVlrAckT

Timer Name

G_MCF Wait VlrAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

4-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


4-6

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 5
Timers Related with G_Common
Module

5.1 Timer 201099


Macro Name of Timer

mcWaitLocalAnmT

Timer Name

G_WaitLocalAnm

Value Range

0~86400000ms

Default Duration
60000ms

Adjustment Step Length

1ms

Flow Description

During the local call or local outgoing service, the G_Common module starts this
timer, and waits for a StartConvEvent message from the peer end. If this timer
expires, the G_Common module releases the call.

5.2 Timer 201100


Macro Name of Timer

5-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

mcWaitNatAnmT

Timer Name

G_WaitNatAnm

Value Range

0~86400000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

During the national toll service, the G_Common module starts this timer, and waits
for a StartConvEvent message from the peer end. If this timer expires, the
G_Common module releases the call.

5.3 Timer 201101


Macro Name of Timer

mcWaitIntAnmT

Timer Name

G_WaitIntAnm

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

During the international toll service, the G_Common module starts this timer, and

5-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 5 Timers Related with G_Common Module

waits for a StartConvEvent message from the peer end. If this timer expires, the
G_Common module releases the call.

5-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


5-4

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6
Timers Related with G_HO Module

6.1 Timer 201111


Macro Name of Timer

mchRlcWtChannelT

Timer Name

G_HO_RlcWtChannelT

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

During the intra-office, basic inter-office, or subsequent handover, after sending a


handover request to the target side, or sending a bearer preparation request to the
H.248 module, the HO module starts this timer, and waits for the corresponding
response message. If this timer expires, the HO module cancels the handover.

6.2 Timer 201112


Macro Name of Timer

mchRlcWtAccessT
Timer Name

6-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_HO_RlcWtAccessT

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

During the intra-office, basic inter-office, or subsequent handover, after sending a


handover request to the source side, the target side starts this timer, and waist for
the wireless terminal to be accessed.

6.3 Timer 201113


Macro Name of Timer

mchARlcWtAckT

Timer Name

G_HO_ARlcWtAckT

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

During the basic inter-office or subsequent handover, after sending an MAP


handover request to the target side, side A starts this timer, and waits for a response
from the target side.

6-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with G_HO Module

6.4 Timer 201114


Macro Name of Timer

mchARlcWtCmpT

Timer Name

G_HO_ARlcWtCmpT

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

During the basic inter-office or subsequent handover, after sending a handover


command to the target side, side A starts this timer, and waits for a response to the
MAP handover completion message from the target side.

6.5 Timer 201115


Macro Name of Timer

mchAWtTpInfoT
Timer Name
G_HO_AWtTpInfoT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

6-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

During the basic inter-office or subsequent handover, after applying for an outgoing
circuit, side A starts this timer, and waits for the corresponding response from the
NNI module.

6.6 Timer 201116


Macro Name of Timer

mchAWtAlertT

Timer Name

G_HO_AWtAlertT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the basic inter-office or subsequent handover, after sending a setup


message to the NNI module, side A starts this timer, and waits for an Alerting
message from the NNI module.

6.7 Timer 201117


Macro Name of Timer

mchAWtConvT

Timer Name

G_HO_AWtConvT

Value Range

0~86400000ms

6-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with G_HO Module

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is used for the TDGSM handover.

6.8 Timer 201118


Macro Name of Timer

mchARlcWtSHCmpT

Timer Name

G_HO_ARlcWtSHCmpT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the subsequent handover, after sending an mcPSHACKEvent message, side


A starts this timer.

6.9 Timer 201119


Macro Name of Timer

mchBWtMshnT

Timer Name

G_HO_BWtMshnT

6-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the inter-office handover, after sending a request for the handover number to
the database, side B starts this timer.

6.10 Timer 201120


Macro Name of Timer

mchBWtSetupT

Timer Name

G_HO_BWtSetupT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the basic inter-office handover, after sending a PHACK message to side A,
side B starts this timer.

6.11 Timer 201121


Macro Name of Timer

6-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with G_HO Module

mchBWtAssignCmpT

Timer Name

G_HO_BWtAssignCmpT

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

After the basic inter-office handover without circuits is completed, when side B
assigns the Rab, it starts this timer.

6.12 Timer 201122


Macro Name of Timer

mchBRlcWtAccessT

Timer Name

G_HO_BRlcWtAccessT

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

During the basic inter-office handover without circuits, after sending a PHACK
message, side B starts this timer. During the basic inter-office handover with circuits,

6-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

when HO module needs to wait for an OpConnected message from the NNI module,
after the HO module sends an Alerting message, it starts this timer. When the HO
module needs to wait for an OpConnected message from the NNI module, the HO
module directly starts this timer.

6.13 Timer 201123


Macro Name of Timer

mchBRlcWtSHAckT

Timer Name

G_HO_BRlcWtSHAckT

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

During the subsequent handover, after sending a HoRequire or RlcRequire


message, side B starts this timer.

6.14 Timer 201124


Macro Name of Timer

mchBRlcWtSHCmpT

Timer Name

G_HO_BRlcWtSHCmpT

Value Range

0~86400000ms

Default Duration
6-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with G_HO Module

15000ms

Adjustment Step Length

1ms

Flow Description

During the subsequent handover, after sending a handover command request


(RlcCmd or HoCmd), side B starts this timer.

6.15 Timer 201125


Macro Name of Timer

mchBWtDiscT

Timer Name

G_HO_BWtDiscT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

When the handover is released at side B, if the NNI module still exists, this timer is
started.

6.16 Timer 201129


Macro Name of Timer

mchScanTimeT

Timer Name

G_HO_ScanTimeT

6-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

This timer is a periodical scanning timer for activation tests.

6.17 Timer 201130


Macro Name of Timer

mch248ActionT

Timer Name

G_HO_248ActionT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After sending an operation request to the H.248 module, the HO module starts this
timer.

6.18 Timer 201131


Macro Name of Timer

mchRlcWtCicT

6-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 6 Timers Related with G_HO Module

Timer Name

G_HO_RlcWtCicT

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the 2G intra-office handover at side A, after the HO module sends an


mbGetBscCicReqEvent message, it starts this timer.
Timer 201132

Macro Name of Timer

mchWtBearIndT

Timer Name

G_HO_WtBearIndT

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

When the H.248 status machine is operated, after the HO module sends a bearer
establishment request, it starts this timer.

6-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

6.19 Timer 201133


Macro Name of Timer

mch248BmT

Timer Name

G_HO_248BmT

Value Range

0~86400000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

After sending a setup message to the BCBM module, the H.248 status machine
starts this timer.

6-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 7
Timers Related with G_MSCMAP
Module

7.1 Timer 201141


Macro Name of Timer

mcmWtRoutT

Timer Name

G_MSCMAP Wait Routing Complete

Value Range

5000~86400000ms

Default Duration
100000ms

Adjustment Step Length

1ms

Flow Description

When the MSCMAP module receives a routing request message from the GMSC
process, it starts this timer. When the service normally ends, the MSCMAP module
stops this timer. If this timer expires, the MSCMAP module releases the service.

7.2 Timer 201142


Macro Name of Timer

7-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

mcmWtHOCmpT

Timer Name

G_MSCMAP Wait HO Complete

Value Range

1000~86400000ms

Default Duration

100000ms

Adjustment Step Length

1ms

Flow Description

When the MSCMAP module receives a request for starting a handover procedure
from the HO module or the MSCMAP module of another office, it starts this timer.
When the handover procedure enters the stable status or fails, the MSCMAP
module stops this timer. If this timer expires, the MSCMAP module releases the
service.

7.3 Timer 201143


Macro Name of Timer

mcmWtEndTalkT

Timer Name

G_MSCMAP Wait End Talk afterHO

Value Range

1000~172800000ms
Default Duration
86400000ms

Adjustment Step Length

1ms

Flow Description

7-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with G_MSCMAP Module

When the handover enters the stable status, the MSCMAP module starts this timer.
After the call is released, or the subscriber moves to another MSC subsequently,
the MSCMAP module stops this timer. If this timer expires, the MSCMAP module
releases the service.

7.4 Timer 201144


Macro Name of Timer

mcmWtMOSMST

Timer Name

G_MSCMAP Wait MO SMS

Value Range

5000~86400000ms

Default Duration

210000ms

Adjustment Step Length

1ms

Flow Description

During the SMS-MO procedure, when the MSCMAP module receives a MO short
message from the MM module, it starts this timer. When the short message is
successfully sent or fails to be sent, the MSCMAP module stops this timer. If this
timer expires, the MSCMAP module releases the service.

7.5 Timer 201145


Macro Name of Timer

mcmWtMTSMST

Timer Name

G_MSCMAP Wait MT SMS

Value Range

5000~86400000ms
7-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Default Duration

100000ms

Adjustment Step Length

1ms

Flow Description

When the MSCMAP module receives a short message from the SC or the module,
it starts this timer. When the MT short message is successfully sent or any
exceptional message is received, the MSCMAP module stops this timer. If this timer
expires, the MSCMAP module releases the service.

7.6 Timer 201146


Macro Name of Timer

mcmWtRepSMT

Timer Name

G_MSCMAP Wait StatusReportCmpl

Value Range

1000~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

When an MT short message is successfully sent or fails to be sent, and if it is


required to start status reports, the MSCMAP module starts this timer. When the
short-message status report procedure normally ends or any exceptional message
is received, the MSCMAP module stops this timer. If this timer expires, the
MSCMAP module releases the service.

7-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with G_MSCMAP Module

7.7 Timer 201147


Macro Name of Timer

mcmWtSSNoteT

Timer Name

G_MSCMAP Wait SSInvokeNoteCmpl

Value Range

5000~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

When the MSCMAP module receives a supplementary-service invoking notification


message from the VLR, it starts this timer. When the MSCMAP module receives an
acknowledgement message of the supplementary-service invoking notification or
exceptional message, it stops this timer. If this timer expires, the MSCMAP module
releases the service.

7.8 Timer 201148


Macro Name of Timer

mcmWtLcsModTimer

Timer Name

G_MSCMAP Wait Lcs Mod Ack

Value Range

1000~86400000ms

Default Duration

20000ms

7-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

The MSCMAP module receives an MT location message from the GMLC module.
When the MSCMAP module receives an mcvGetLcsModAckEvent message from
the VLR, it stops this timer. If this timer expires, the MSCMAP module releases the
service.

7.9 Timer 201149


Macro Name of Timer

mcmWtMTLCS

Timer Name

G_MSCMAP Wait MTLR Complete

Value Range

5000~86400000ms

Default Duration

660000ms

Adjustment Step Length

1ms

Flow Description

The MSCMAP module receives an MT location message from the GMLC module.
When the location is successful or interrupted due to exceptional messages being
received, the MSCMAP module stops this timer. If this timer expires, the MSCMAP
module releases the service.

7.10 Timer 201150


Macro Name of Timer

mcmWtMOLCS

7-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with G_MSCMAP Module

Timer Name

G_MSCMAP Wait MOLR Complete

Value Range

5000~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

The MSCMAP module receives an mcvSendLocInfoToGmlcReqEvent message


from the VLR. When the MSCMAP module successful receives a response or fails
to receive a response due to receiving exceptional messages, it stops this timer. If
this timer expires, the MSCMAP module releases the service.

7.11 Timer 201151


Macro Name of Timer

mcmScanTimeT

Timer Name

G_MSCMAP Scan

Value Range

1000~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After the MSCMAP module in the initial status receives a message of the active
7-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

server being powered on, it starts this timer. When the active server is switched to
the standby one, the MSCMAP module stops this timer. When this timer expires, the
MSCMAP module scans the data areas, and releases those exceeding the pre-set
usage duration.

7.12 Timer 201152


Macro Name of Timer

mcmWaitMChangeOverT

Timer Name

G_MSCMAP Wait MChangeOver


Value Range
0~20000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the active/standby switching, when the standby server is switched to the
active one, the MSCMAP module starts this timer, and waits for the originally active
server to be successfully switched to the standby one. When the MSCMAP module
receives a message of the active server being successfully switched to the standby
one, it stops this timer. If this timer expires, the original standby server is forcibly
switched to the active one.

7.13 Timer 201153


Macro Name of Timer

mcmWtRCHCmpT

Timer Name

G_MSCMAP Wait RCHCmp

Value Range

7-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 7 Timers Related with G_MSCMAP Module

5000~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

In the following two cases, the MSCMAP module starts this timer.
The MSCMAP module receives an mcRCHReqEvent message from the
MCC module.
The MSCMAP module receives a call-processing recovery message
from the peer-end VMSC.
In the following two cases, the MSCMAP module stops this timer.
The MSCMAP module receives a call-processing recovery response
message from the GMSC module.
The MSCMAP module receives an mcRCHRspEvent (call-processing
recovery) or mcGmscAndMscmapReleaseEvent message from the
GMSC module.
If this timer expires, the MSCMAP module releases the service.

7.14 Timer 201500


Macro Name of Timer

mlACnetworkUnstructSsTimer

Timer Name

G_MSCMAP_USSDMT

Value Range

0~86400000ms

Default Duration

600000ms

Adjustment Step Length

1ms

7-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

After receiving the USSD MT service, the MSCMAP module starts this timer. If this
timer expires, the MSCMAP module releases the service.

7-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP
Module

8.1 Timer 201161


Macro Name of Timer

mvmTMSIReallocTimer

Timer Name

G_VLRMAP Wait ReallTmsiAck

Value Range

1000~86400000ms

Default Duration

40000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module sends a joint location-update acceptance response,


and needs to allocate the TMSI, it starts this timer. When the VLRMAP module
receives a TMSI re-allocation completion message from the SGSN, it stops this
timer. If this timer expires, it is considered that the location update is successful, and
that both the new TMSI and the old one are saved in the database.

8-11

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

8.2 Timer 201162


Macro Name of Timer

mvmPageTimer

Timer Name

G_VLRMAP Wait PageRsp

Value Range

1000~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module sends a paging request message to the MM module, it
starts this timer. When the VLRMAP module receives an access request message
or a paging failure message from the MM module, it stops this timer. If this timer
expires, the VLRMAP module releases the service.

8.3 Timer 201163


Macro Name of Timer

mvmAlertTimer

Timer Name

G_VLRMAP SMS Alert

Value Range

1000~86400000ms

Default Duration

4000ms

Adjustment Step Length

8-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP Module

1ms

Flow Description

The VRL failed to send the short message. If this MS is both GPRS attached and
IMSI attached, the VLR starts this timer after sending an alert request to the SGSN.
When the VLR receives an alert response from the SGSN, it stops this timer. If this
timer expires, and the VLR has received no response, the VLR needs to re-send the
request. If the VLR still does not successfully receive a response after the number
of resent requests reaches a certain value, the VLR reports it to the OMC.

8.4 Timer 201164


Macro Name of Timer

mvmMsInfoTimer
Timer Name
G_VLRMAP PvdMsInfo

Value Range

1000~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

After the VLR sends a message to ask the SGSN for the subscriber data, it starts
this timer. When the VLR receives a message containing the subscriber data from
the SGSN, it stops this timer. If this timer expires, the VLR releases the service.

8.5 Timer 201165


Macro Name of Timer

mvmResetTimer

Timer Name

G_VLRMAP Notify SGSN Reset


8-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

4000ms

Adjustment Step Length

1ms

Flow Description

When the system is powered on, it starts this timer, which is used for the Gs to send
a Reset message. If this timer expires, the VLR sends a Reset message to the
SGSN.

8.6 Timer 201167


Macro Name of Timer

mvmProtectTimer

Timer Name

G_VLRMAP ProtectDataArea

Value Range

1000~86400000ms

Default Duration

200000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module applies for a data area, it starts this timer. When the
service normally ends, the VLRMAP module stops this timer. If this timer expires,
the VLRMAP module releases the service.

8-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP Module

8.7 Timer 201169


Macro Name of Timer

mvmLocRepTimer

Timer Name

G_VLRMAP Wait LocReport

Value Range

1000~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module sends a location request message to the MM module, it
starts this timer. When the VLRMAP module receives a location response message,
it stops this timer. If this timer expires, the VLRMAP module releases the service.

8.8 Timer 201170


Macro Name of Timer

mvmNotifRetResTimer

Timer Name

G_VLRMAP LCS Wait NotifAck

Value Range

1000~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms
8-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

During the MS-terminated location, when it is required to notify the subscriber


according to the subscription information of the subscriber, the VLRMAP module
starts this timer. When the VLRMAP module receives a notification success
message or notification failure message from the MM module, it stops this timer. If
this timer expires, the VLRMAP module determines whether to perform the location
according to the subscription information of the subscriber.

8.9 Timer 201171


Macro Name of Timer

mvmWFMolrTimer

Timer Name

G_VLRMAP LCS Wait next MOLR

Value Range

1000~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

After the calling party is successfully located, the VLRMAP module starts this timer,
and waits for the next location request. When the calling-party location request
actively initiated by the MS ends, the VLRMAP module stops this timer. If this timer
expires, the VLRMAP module releases the MM and VLR data areas.

8.10 Timer 201172


Macro Name of Timer

mvmWFSndLocToGmlcTimer

Timer Name

G_VLRMAP Send Loc To Gmlc


8-16

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP Module

Value Range

1000~86400000ms

Default Duration

50000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module sends a location report request message to the MM
module, it starts this timer. When the VLRMAP module receives a location report
response message, it stops this timer. If this timer expires, the VLRMAP module
releases the service.

8.11 Timer 201173


Macro Name of Timer

mvmScanTimeT

Timer Name

G_VLRMAP Scan

Value Range

1000~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After the VLRMAP module in the initial status receives a message of the active
server being powered on, it starts this timer. When the active server is switched to
the standby one, the VLRMAP module stops this timer. When this timer expires, the
VLRMAP module scans the data areas, and releases those exceeding the pre-set
usage duration.

8-17

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

8.12 Timer 201174


Macro Name of Timer

mvmWaitMChangeOverT

Timer Name

G_VLRMAP Wait MChangeOverT

Value Range

0~20000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the active/standby switching, when the standby server is switched to the
active one, the VLRMAP module starts this timer, and waits for the originally active
server to be successfully switched to the standby one. When the VLRMAP module
receives a message of the active server being successfully switched to the standby
one, it stops this timer. If this timer expires, the original standby server is forcibly
switched to the active one.

8.13 Timer 201175


Macro Name of Timer

mvmReSendDeferLocReqTimer

Timer Name

G_VLRMAP ReSendDeferLocReq

Value Range

1000~86400000ms

Default Duration

60000ms

8-18

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP Module

Adjustment Step Length

1ms

Flow Description

During the MS-terminated location, if the paging fails with failure cause as "Network
Determined User Busy", and the subscriber delay location flag has been set, the
VLRMAP module starts this timer. If this timer expires, the VLRMAP module
resends a location request message.

8.14 Timer 201176


Macro Name of Timer

mvmDeferLocReqTimer

Timer Name

G_VLRMAP DeferLocReq

Value Range

1000~86400000ms

Default Duration

3600000ms

Adjustment Step Length

1ms

Flow Description

When the VLRMAP module receives a location delay request, it starts this timer.
When the location delay is successful, this timer is stopped. If this timer expires,
VLRMAP module releases the service.

8.15 Timer 201177


Macro Name of Timer

mvmWaitSndWelSMSTimer

Timer Name

8-19

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_VLRMAP Wait for Welcome SMS

Value Range

1000~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After the location update procedure ends, the VLRMAP module starts this timer
when it is required to send a welcome message. If this timer expires, the VLRMAP
module starts the welcome message procedure.

8.16 Timer 201178


Macro Name of Timer

mvmDHLUTimer

Timer Name

G_VLRMAP DHLU

Value Range

1000~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

When the system is powered on, it starts this timer. This timer controls the ratio of
the subscribers with asynchronous dual-homing data whose locations are updated
to the HLR within each timer duration. If this timer expires, the VLRMAP module
clears the data accumulated in the previous period of time, and re-calculates the

8-20

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 8
Timers Related with G_VLRMAP Module

ratio.

8-21

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


8-22

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9
Timers Related with G_TM Module

9.1 Timer 201211


Macro Name of Timer

mlSigMPResetTimer

Timer Name

G_TM SigMPReset

Value Range

0~86400000ms

Default Duration

1000ms

Adjustment Step Length

1ms

Flow Description

This timer is for releasing unreliable data areas.

9.2 Timer 201214


Macro Name of Timer

mlWaitMChangeOverT

Timer Name

G_TM WaitMChangeOver

9-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is for active/standby switching of the TM module.

9.3 Timer 201215


Macro Name of Timer

mlHOSteadyTimer

Timer Name

G_TM HOSteady

Value Range

0~86400000ms

Default Duration

86400000ms

Adjustment Step Length

1ms

Flow Description

This timer is for dialog protection in HO steady status.

9.4 Timer 201216


Macro Name of Timer

mlCapPDBTimer

9-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

Timer Name

G_TM CapPDB

Value Range

0~86400000ms

Default Duration

86400000ms

Adjustment Step Length

1ms

Flow Description

This timer is for dialog protection in the CAP service.

9.5 Timer 201219


Macro Name of Timer

mlOmapPDBTimer

Timer Name

G_TM OmapPDB

Value Range

0~86400000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

This timer is for dialog protection in the CAP service.

9-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

9.6 Timer 201220


Macro Name of Timer

mlOmapActionTimer

Timer Name

G_TM OmapAction

Value Range

0~86400000ms

Default Duration

80000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for VT operations.

9.7 Timer 201233


Macro Name of Timer

mmUpLocTimer

Timer Name

G_TM UpLoc

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

This timer is a protection timer for "updateLocation" operations.

9.8 Timer 201234


Macro Name of Timer

mmCnlLocTimer

Timer Name

G_TM CnlLoc

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for collectInformation operations.

9.9 Timer 201235


Macro Name of Timer

mmRomNumTimer

Timer Name

G_TM RomNum

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

This timer is a protection timer for provideRoamingNumber operations.

9.10 Timer 201237


Macro Name of Timer

mmRCHTimer

Timer Name

G_TM RCH

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for resumeCallHandling operations.

9.11 Timer 201238


Macro Name of Timer

mmInsUsrDataTimer

Timer Name

G_TM InsUsrData

Value Range

0~86400000ms

Default Duration

9-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for insertSubscriberData operations.

9.12 Timer 201239


Macro Name of Timer

mmDelUsrDataTimer

Timer Name

G_TM DelUsrData

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for deleteSubscriberData operations.

9.13 Timer 201240


Macro Name of Timer

mmSndParaTimer

Timer Name

G_TM SndPara

Value Range

9-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendParameters operations.

9.14 Timer 201241


Macro Name of Timer

mmRegSSTimer

Timer Name

G_TM RegSS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for registerSS operations.

9.15 Timer 201242


Macro Name of Timer

mmErsSSTimer

Timer Name

9-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

G_TM ErsSS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for eraseSS operations.

9.16 Timer 201243


Macro Name of Timer

mmActSSTimer

Timer Name

G_TM ActSS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for activateSS operations.

9.17 Timer 201244


Macro Name of Timer

9-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

mmDetSSTimer

Timer Name

G_TM DetSS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for deactivateSS operations.

9.18 Timer 201245


Macro Name of Timer

mmIgtSSTimer

Timer Name

G_TM IgtSS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for interrogateSS operations.

9-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

9.19 Timer 201246


Macro Name of Timer

mmAuthFailTimer

Timer Name

G_TM AuthFail

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for authenticationFailureReport operations.

9.20 Timer 201248


Macro Name of Timer

mmRegPwdTimer

Timer Name

G_TM RegPwd

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

This timer is a protection timer for registerPassword operations.

9.21 Timer 201249


Macro Name of Timer

mmGetPwdTimer

Timer Name

G_TM GetPwd

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for getPassword operations.

9.22 Timer 201253


Macro Name of Timer

mmSndRutInfoTimer

Timer Name

G_TM SndRutInfo

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

1ms

Flow Description

This timer is a protection timer for sendRoutingInfo operations.

9.23 Timer 201254


Macro Name of Timer

mmUpdateGPRSLocTimer

Timer Name

G_TM UpdateGPRSLoc

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for updateGprsLocation operations.

9.24 Timer 201255


Macro Name of Timer

mmSndRoutInfoGPRSTimer

Timer Name

G_TM SndRoutInfoGPRS

Value Range

0~86400000ms

Default Duration

9-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendRoutingInfoForGprs operations.

9.25 Timer 201256


Macro Name of Timer

mmFailureReportTimer

Timer Name

G_TM FailureReport

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for failureReport operations.

9.26 Timer 201257


Macro Name of Timer

mmNoteMSPreForGPRSTimer

Timer Name

G_TM NoteMSPreForGPRS

Value Range

9-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for noteMsPresentForGprs operations.

9.27 Timer 201259


Macro Name of Timer

mmPerfHandTimer

Timer Name

G_TM PerfHand

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for performHandover operations.

9.28 Timer 201260


Macro Name of Timer

mmSndEndSigTimer

Timer Name

9-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_TM SndEndSig

Value Range

0~172800000ms

Default Duration

86400000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendEndSignal operations.

9.29 Timer 201261


Macro Name of Timer

mmPerfSubHandTimer

Timer Name

G_TM PerfSubHand

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for performSubsequentHandover operations.

9.30 Timer 201264


Macro Name of Timer

9-16

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

mmProcAccSigTimer

Timer Name

G_TM ProcAccSig

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for processAccessSignalling operations.

9.31 Timer 201265


Macro Name of Timer

mmFordAccSigTimer

Timer Name

G_TM FordAccSig

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for forwardAccessSignalling operations.

9-17

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

9.32 Timer 201266


Macro Name of Timer

mmNoteInterHandTimer

Timer Name

G_TM NoteInterHand

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for noteInternalHandover operations.

9.33 Timer 201268


Macro Name of Timer

mmRetTimer

Timer Name

G_TM Ret

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-18

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

This timer is a protection timer for reset operations.

9.34 Timer 201269


Macro Name of Timer

mmFordChkSSTiemr

Timer Name

G_TM FordChkSSTiemr

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for forwardCheckSS-Indication operations.

9.35 Timer 201274


Macro Name of Timer

mmChkIMEITimer

Timer Name

G_TM ChkIMEI

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-19

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

This timer is a protection timer for checkIMEI operations.

9.36 Timer 201275


Macro Name of Timer

mmMTFwdSMTimer

Timer Name

G_TM MTFwdSM

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for mt-forwardSM operations.

9.37 Timer 201276


Macro Name of Timer

mmSndRutSMTimer

Timer Name

G_TM SndRutSM

Value Range

0~86400000ms

Default Duration

9-20

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendRoutingInfoForSM operations.

9.38 Timer 201277


Macro Name of Timer

mmFordSMTimer

Timer Name

G_TM FordSM

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for mo-forwardSM operations.

9.39 Timer 201278


Macro Name of Timer

mmSMDlyTimer

Timer Name

G_TM SMDly

Value Range

9-21

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for reportSM-DeliveryStatus operations.

9.40 Timer 201279


Macro Name of Timer

mmNoteSubTimer

Timer Name

G_TM NoteSub

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for noteSubscriberPresent operations.

9.41 Timer 201280


Macro Name of Timer

mmAlertScNoResTimer
Timer Name
G_TM AlertScNoRes

9-22

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for alertServiceCentreWithoutResult operations.

9.42 Timer 201281


Macro Name of Timer

mmActTceModeTimer

Timer Name

G_TM ActTceMode

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for activateTraceMode operations.

9.43 Timer 201282


Macro Name of Timer

mmDctTceModeTimer

9-23

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Timer Name

G_TM DctTceMode

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for deactivateTraceMode operations.

9.44 Timer 201285


Macro Name of Timer

mmBegSubActTimer

Timer Name

G_TM BegSubAct

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for beginSubscriberActivity operations.

9-24

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

9.45 Timer 201286


Macro Name of Timer

mmSndSubIDTimer

Timer Name

G_TM SndSubID

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendIdentification operations.

9.46 Timer 201287


Macro Name of Timer

mmSndAuthTimer

Timer Name

G_TM SndAuth

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-25

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

This timer is a protection timer for sendAuthenticationInfo operations.

9.47 Timer 201288


Macro Name of Timer

mmRtrDataTimer

Timer Name

G_TM RtrData

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for restoreData operations.

9.48 Timer 201289


Macro Name of Timer

mmSndIMSITimer

Timer Name

G_TM SndIMSI

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-26

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

1ms

Flow Description

This timer is a protection timer for sendIMSI operations.

9.49 Timer 201290


Macro Name of Timer

mmUNSrcSSTimer

Timer Name

G_TM UNSrcSS

Value Range

0~86400000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for processUnstructuredSS-Request operations.

9.50 Timer 201291


Macro Name of Timer

mmUNSrcSSRTimer

Timer Name

G_TM UNSrcSSR

Value Range

0~86400000ms

Default Duration

9-27

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for unstructuredSS-Request operations.

9.51 Timer 201292


Macro Name of Timer

mmUNSrcSSCTiemr

Timer Name

G_TM UNSrcSSCTiemr

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for unstructuredSS-Notify operations.

9.52 Timer 201293


Macro Name of Timer

mmAnyTimeSubIntTimer

Timer Name

G_TM AnyTimeSubInt

Value Range

9-28

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for anyTimeSubscriptionInterrogation operations.

9.53 Timer 201294


Macro Name of Timer

mmInfSCTimer

Timer Name

G_TM InfSC

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for informServiceCentre operations.

9.54 Timer 201295


Macro Name of Timer

mmArtSCTimer

Timer Name

9-29

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_TM ArtSC

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for alertServiceCentre operations.

9.55 Timer 201296


Macro Name of Timer

mmAnyTimeModiTimer

Timer Name

G_TM AnyTimeModi

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for anyTimeModification operations.

9.56 Timer 201297


Macro Name of Timer

9-30

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

mmRdySMTiemr

Timer Name

G_TM RdySMTiemr

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for readyForSM operations.

9.57 Timer 201298


Macro Name of Timer

mmPugMSTimer

Timer Name

G_TM PugMS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for purgeMS operations.

9-31

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

9.58 Timer 201299


Macro Name of Timer

mmPreHndTimer

Timer Name

G_TM PreHnd

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for prepareHandover operations.

9.59 Timer 201300


Macro Name of Timer

mmPreSubHndTimer

Timer Name

G_TM PreSubHnd

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-32

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

This timer is a protection timer for prepareSubsequentHandover operations.

9.60 Timer 201301


Macro Name of Timer

mmPvdSubInfoTimer

Timer Name

G_TM PvdSubInfo

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for provideSubscriberInfo operations.

9.61 Timer 201302


Macro Name of Timer

mmAnyTimeIntTimer

Timer Name

G_TM AnyTimeInt

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-33

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

This timer is a protection timer for anyTimeInterrogation operations.

9.62 Timer 201303


Macro Name of Timer

mmSSInvNotifiTimer

Timer Name

G_TM SSInvNotifi

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for ss-InvocationNotification operations.

9.63 Timer 201304


Macro Name of Timer

mmSetRepStateTimer

Timer Name

G_TM SetRepState

Value Range

0~86400000ms

Default Duration

9-34

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for setReportingState operations.

9.64 Timer 201305


Macro Name of Timer

mmStateRepTimer

Timer Name

G_TM StateRep

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for statusReport operations.

9.65 Timer 201306


Macro Name of Timer

mmRemoteUserFreeTimer

Timer Name

G_TM RemoteUserFree

Value Range

9-35

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for remoteUserFree operations.

9.66 Timer 201307


Macro Name of Timer

mmRegCCEntryTimer

Timer Name

G_TM RegCCEntry

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for RegCCEntry operations.

9.67 Timer 201308


Macro Name of Timer

mmEraseCCEntryTimer

Timer Name

9-36

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

G_TM EraseCCEntry

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms
Flow Description
This timer is a protection timer for EraseCCEntry operations.

9.68 Timer 201314


Macro Name of Timer

mmProvSubLocTimer

Timer Name

G_TM ProvSubLoc

Value Range

0~86400000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for provideSubscriberLocation operations.

9.69 Timer 201316


Macro Name of Timer

mmSndRouteInfForLCSTimer

9-37

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Timer Name

G_TM SndRouteInfForLCS

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendRoutingInfoForLCS operations.

9.70 Timer 201317


Macro Name of Timer

mmSubLocReportTimer

Timer Name

G_TM SubLocReport

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for subscriberLocationReport operations.

9-38

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

9.71 Timer 201318


Macro Name of Timer

mmISTAlertTimer

Timer Name

G_TM ISTAlert

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for istAlert operations.

9.72 Timer 201319


Macro Name of Timer

mmISTCommandTimer

Timer Name

G_TM ISTCoG_TM and

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

9-39

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

This timer is a protection timer for istCommand operations.

9.73 Timer 201320


Macro Name of Timer

mmNoteMMEventTimer

Timer Name

G_TM NoteG_TM Event

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for noteMM-Event operations.

9.74 Timer 201321


Macro Name of Timer

mmAlterSubPATimer

Timer Name

G_TM AlterSubPA

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

9-40

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 9 Timers Related with G_MCC Module

1ms

Flow Description

This timer is a protection timer for AlterSubPA operations.

9.75 Timer 201322


Macro Name of Timer

mmLocNotifyTimer

Timer Name

G_TM LocNotify

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for locationNotify operations.

9-41

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


9-42

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10
Timers Related with G_TCAP
Module

10.1 Timer 201381


Macro Name of Timer

capOpCdInitialDPTimer

Timer Name

G_TCAP OpCdInitialDP

Value Range

0~86400000ms

Default Duration
10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for initialDP operations.

10.2 Timer 201397


Macro Name of Timer

capOpCdAssistRequestInstructionTimer

Timer Name
10-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

G_TCAP OpCdAssistReqInstruction

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for assistRequestInstructions operations.

10.3 Timer 201398


Macro Name of Timer

capOpCdEstTemporaryConnectionTimer

Timer Name

G_TCAP OpCdEstTempConnection

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for establishTemporaryConnection operations.

10.4 Timer 201399


Macro Name of Timer

10-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

capOpCdDiscForwardConnectionTimer

Timer Name

G_TCAP OpCdDiscFwdConnection

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for disconnectForwardConnection operations.

10.5 Timer 201400


Macro Name of Timer

capOpCdConnectToResourceTimer

Timer Name

G_TCAP OpCdConnectToResource

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for connectToResource operations.

10-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

10.6 Timer 201401


Macro Name of Timer

capOpCdConnectTimer

Timer Name

G_TCAP OpCdConnect

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for connect operations.

10.7 Timer 201403


Macro Name of Timer

capOpCdReleaseCallTimer

Timer Name

G_TCAP OpCdReleaseCall

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

10-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

This timer is a protection timer for releaseCall operations.

10.8 Timer 201404


Macro Name of Timer

capOpCdRequestReportBCSMEventTimer

Timer Name

G_TCAP OpCdReqReportBCSMEvent

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for requestReportBCSMEvent operations.

10.9 Timer 201405


Macro Name of Timer

capOpCdEventReportBCSMTimer

Timer Name

G_TCAP OpCdEventReportBCSM

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

10-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

This timer is a protection timer for eventReportBCSM operations.

10.10 Timer 201408


Macro Name of Timer

capOpCdCollectInformationTimer

Timer Name

G_TCAP OpCdCollectInformation

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for collectInformation operations.

10.11 Timer 201412


Macro Name of Timer

capOpCdContinueTimer

Timer Name

G_TCAP OpCdContinue

Value Range

0~86400000ms

Default Duration

10-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for continue operations.

10.12 Timer 201413


Macro Name of Timer

capOpCdInitCallAttemptTimer

Timer Name

G_TCAP OpCdInitCallAttempt

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for initiateCallAttempt operations.

10.13 Timer 201414


Macro Name of Timer

capOpCdResetTimerTimer

Timer Name

G_TCAP OpCdResetTimer

Value Range

10-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for resetTimer operations.

10.14 Timer 201415


Macro Name of Timer

capOpCdFurnishChargingInfoTimer

Timer Name

G_TCAP OpCdFurnishChargingInfo

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for furnishChargingInformation operations.

10.15 Timer 201416


Macro Name of Timer

capOpCdApplyChargingTimer

Timer Name

10-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

G_TCAP OpCdApplyCharging

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for applyCharging operations.

10.16 Timer 201417


Macro Name of Timer

capOpCdApplyChargingReportTimer

Timer Name

G_TCAP OpCdApplyChargingReport

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for applyChargingReport operations.

10.17 Timer 201422


Macro Name of Timer

10-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

capOpCdCallGapTimer

Tim er Name

G_TCAP OpCdCallGap

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for callGap operations.

10.18 Timer 201423


Macro Name of Timer

capOpCdActivateServFilterTimer

Timer Name

G_TCAP OpCdActivateServFilter

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for playTone operations.

10-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

10.19 Timer 201424


Macro Name of Timer

capOpCdServFilteringRspTimer

Timer Name

G_TCAP OpCdServFilteringRsp

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for playTone operations.

10.20 Timer 201425


Macro Name of Timer

capOpCdCallInformationReportTimer

Timer Name

G_TCAP OpCdCallInfoReport

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

10-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

This timer is a protection timer for callInformationReport operations during the


INAP/CAP service.

10.21 Timer 201426


Macro Name of Timer

capOpCdCallInformationRequestTimer

Timer Name

G_TCAP OpCdCallInfoRequest

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for callInformationRequest operations during the


INAP/CAP service.

10.22 Timer 201427


Macro Name of Timer

capOpCdSendChargingInformationTimer

Timer Name

G_TCAP OpCdSendChargingInfo

Value Range

0~86400000ms

Default Duration

10000ms

10-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendChargingInformation operations during the


INAP/CAP service.

10.23 Timer 201428


Macro Name of Timer

capOpCdPlayAnnouncementTimer

Timer Name

G_TCAP OpCdPlayAnnouncement

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for playAnnouncement operations during the


INAP/CAP service.

10.24 Timer 201429


Macro Name of Timer

capOpCdPromptAndCollectUserInfoTimer

Timer Name

G_TCAP OpCdPromptCollectUsrInfo

Value Range

10-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for promptAndCollectUserInformation operations


during the INAP/CAP service.

10.25 Timer 201430


Macro Name of Timer

capOpCdSpecializedResourceReportTimer

Timer Name

G_TCAP OpCdSpecializedResReport

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for specializedResourceReport operations during the


INAP/CAP service.

10.26 Timer 201434


Macro Name of Timer

capOpCdCancelTimer

10-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Timer Name

G_TCAP OpCdCancel

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for cancel operations during the INAP/CAP service.

10.27 Timer 201436


Macro Name of Timer

capOpCdActivityTestTimer

Timer Name

G_TCAP OpCdActivityTest

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for activityTest operations during the INAP/CAP
service.

10-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

10.28 Timer 201437


Macro Name of Timer

capOpCdContinueWithArgumentTimer

Timer Name

G_TCAP OpCdContinueWithArgument

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for continueWithArgument operations during the


CAP service.

10.29 Timer 201441


Macro Name of Timer

capOpCdInitialDPSMSTimer

Timer Name

G_TCAP OpCdInitialDPSMS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

10-16

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Flow Description

This timer is a protection timer for initialDPSMS operations during the CAP service.

10.30 Timer 201442


Macro Name of Timer

capOpCdFurnishChargingInfoSMSTimer

Timer Name

G_TCAP OpCdFurnishChargInfoSMS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for furnishChargingInformationSMS operations


during the CAP service.

10.31 Timer 201443


Macro Name of Timer

capOpcdConnectSMSTimer

Timer Name

G_TCAP OpcdConnectSMS

Value Range

0~86400000ms

Default Duration

20000ms

10-17

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for connectSMS operations during the CAP service.

10.32 Timer 201444


Macro Name of Timer

capOpCdRequestReportSMSEventTimer

Timer Name

G_TCAP OpCdReqReportSMSEvent

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for requestReportSMSEvent operations during the


INAP service.

10.33 Timer 201445


Macro Name of Timer

capOpCdEventReportSMSTimer

Timer Name

G_TCAP OpCdEventReportSMS

Value Range

0~86400000ms

10-18

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for eventReportSMS operations during the CAP
service.

10.34 Timer 201446


Macro Name of Timer

capOpCdContinueSMSTimer

Timer Name

G_TCAP OpCdContinueSMS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for continueSMS operations during the CAP service.

10.35 Timer 201447


Macro Name of Timer

capOpCdReleaseSMSTimer

Timer Name

G_TCAP OpCdReleaseSMS

10-19

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for releaseSMS operations during the CAP service.

10.36 Timer 201448


Macro Name of Timer

capOpCdResetTimerSMSTimer

Timer Name

G_TCAP OpCdResetSMS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for resetTimerSMS operations during the CAP
service.

10.37 Timer 201451


Macro Name of Timer

capActivityTestGPRSTimer

10-20

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Timer Name

G_TCAP ActivityTestGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for activityTestGPRS operations during the CAP
service.

10.38 Timer 201452


Macro Name of Timer

capApplyChargingGPRSTimer

Timer Name

G_TCAP ApplyChargingGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for applyChargingGPRS operations during the CAP
service.

10-21

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

10.39 Timer 201453


Macro Name of Timer

capApplyChargingReportGPRSTimer

Timer Name

G_TCAP ApplyChargingReportGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for applyChargingReportGPRS operations during the


CAP service.

10.40 Timer 201454


Macro Name of Timer

capCancelGPRSTimer

Timer Name

G_TCAP CancelGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

10-22

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Flow Description

This timer is a protection timer for cancelGPRS operations during the CAP service.

10.41 Timer 201455


Macro Name of Timer

capConnectGPRSTimer

Timer Name

G_TCAP ConnectGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for connectGPRS operations during the CAP service.

10.42 Timer 201456


Macro Name of Timer

capContinueGPRSTimer

Timer Name

G_TCAP ContinueGPRS

Value Range

0~86400000ms

Default Duration

20000ms

10-23

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for continueGPRS operations during the CAP
service.

10.43 Timer 201457


Macro Name of Timer

capEntityReleasedGPRSTimer

Timer Name

G_TCAP EntityReleasedGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for entityReleasedGPRS operations during the CAP
service.

10.44 Timer 201458


Macro Name of Timer

capFurnishChargingInfoGPRSTimer

Timer Name

G_TCAP FurnishChargingInfoGPRS

Value Range

10-24

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for furnishChargingInformationGPRS operations


during the CAP service.

10.45 Timer 201459


Macro Name of Timer

capInitialDPGPRSTimer

Timer Name

G_TCAP InitialDPGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for initialDPGPRS operations during the CAP
service.

10.46 Timer 201460


Macro Name of Timer

capReleaseGPRSTimer

10-25

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Timer Name

G_TCAP ReleaseGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for releaseGPRS operations during the CAP service.

10.47 Timer 201461


Macro Name of Timer

capEventReportGPRSTimer

Timer Name

G_TCAP EventReportGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for eventReportGPRS operations during the CAP
service.

10-26

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

10.48 Timer 201462


Macro Name of Timer

capRequestReportGPRSEventTimer

Timer Name

G_TCAP RequestReportGPRSEvent

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for requestReportGPRSEven operations during the


CAP service.

10.49 Timer 201463


Macro Name of Timer

capResetTimerGPRSTimer

Timer Name

G_TCAP ResetGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

10-27

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Flow Description

This timer is a protection timer for resetTimerGPRS operations during the CAP
service.

10.50 Timer 201464


Macro Name of Timer

capSendChargingInfoGPRSTimer

Timer Name

G_TCAP SendChargingInfoGPRS

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for sendChargingInformationGPRS operations during


the CAP service.

10.51 Timer 201467


Macro Name of Timer

capOpCdDFCWithArgumentTimer

Timer Name

G_TCAP OpCdDFCWithArgument

Value Range

0~86400000ms

Default Duration

10-28

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for dFCWithArgument operations during the CAP
service.

10.52 Timer 201469


Macro Name of Timer

capOpCdCPHContinueWithArgTimer

Timer Name

G_TCAP OpCdCPHContinueWithArg

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for CPHcontinueWithArgumen operations during the


CAP service.

10.53 Timer 201471


Macro Name of Timer

capOpCdDisconnectLegTimer

Timer Name

G_TCAP OpCdDisconnectLeg

10-29

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for disconnectLeg operations during the CAP
service.

10.54 Timer 201474


Macro Name of Timer

capOpCdMoveLegTimer

Timer Name

G_TCAP OpCdMoveLeg

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for moveLeg operations during the CAP service.

10.55 Timer 201476


Macro Name of Timer

capOpCdSplitLegTimer

10-30

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 10 Timers Related with G_TCAP Module

Timer Name

G_TCAP OpCdSplitLeg

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for splitLeg operations during the CAP service.

10.56 Timer 201477


Macro Name of Timer

capOpCdEntityReleasedTimer

Timer Name

G_TCAP OpCdEntityReleased

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for playTone operations during the CAP service.

10-31

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

10.57 Timer 201478


Macro Name of Timer

capOpCdPlayToneTimer

Timer Name

G_TCAP OpCdPlayTone

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is a protection timer for playTone operations during the CAP service.

10-32

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 11
Timers Related with G_GSMSSF
Module

11.1 Timer 201611


Macro Name of Timer

SSFTleaf

Timer Name

G_GSMSSF Tleaf

Value Range

0~86400000ms

Default Duration
30000ms

Adjustment Step Length

1ms

Flow Description

The SSF module in the status of not waiting for instructions uses this timer when
monitoring the events of other modules, to avoid being suspended due to failing to
receiving messages for a long time.

11.2 Timer 201612


Macro Name of Timer

11-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

SSFTshort

Timer Name

G_GSMSSF Tshort

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

The SSF module in the status of waiting for instructions uses this timer when wait
for an instruction from the SCP.

11.3 Timer 201613


Macro Name of Timer

SSFTlong

Timer Name

G_GSMSSF Tlong

Value Range

0~86400000ms

Default Duration

600000ms

Adjustment Step Length

1ms

Flow Description

The SSF module in the status of waiting for interaction with users uses this timer
when waiting for the resources to be released after tone play, and an instruction

11-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 11 Timers Related with G_GSMSSF Module

form the SCP.

11.4 Timer 201614


Macro Name of Timer

SSFTccd

Timer Name

G_GSMSSF Tccd

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

This timer specifies the duration of the SSP waiting for the next AC from the SCP
after reporting an ACR to the SCP.

11.5 Timer 201615


Macro Name of Timer

SSFTw

Timer Name

G_GSMSSF Tw

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length


11-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

After this timer expires, the SSF module plays the alarm tone to CAMEL
subscribers.

11-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 12
Timers Related with G_BSSAP
Module

12.1 Timer 206112


Macro Name of Timer

mbTidRESET_R

Timer Name

G_BSSAP Send Reset Ack

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

The CN BSSAP module receives a Reset message from the BSC. After this timer
expires, the CN BSSAP module sends a "Reset Ack" message. Within the valid
duration of this timer, the system recovers the local resources.

12.2 Timer 206113


Macro Name of Timer

mbTidRESET_S

12-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Timer Name

G_BSSAP Wait For ResetAck

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

After sending a Reset message, the CN BSSAP module starts this timer, and waits
for a Reset Ack message from the BSC. If this timer expires, the CN BSSAP
module continues to send Reset messages. The number of sent Reset messages
can be configured, which is three in general. On the Nth expiry of this timer, the CN
BSSAP module considers that the reset is completed.

12.3 Timer 206114


Macro Name of Timer

mbTidRESETCIC

Timer Name

G_BSSAP Wait For ResetCicAck

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After sending a ResetCIC message, the CN BSSAP module starts this timer, and
12-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 12 Timers Related with G_BSSAP Module

waits for a "Reset CIC Ack" message from the BSC. If this timer expires, the CN
BSSAP module continues to send ResetCIC messages. The number of sent
ResetCIC messages can be configured, which is three in general. On the Nth expiry
of this timer, the CN BSSAP module considers that the circuit is successfully reset.

12.4 Timer 206115


Macro Name of Timer

mbTidIGOC

Timer Name

G_BSSAP Congest Short

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN BSSAP module receives an
Over Load message from the BSC, it starts this timer. Before this timer expires, all
the overload messages from the BSC are ignored. After this timer expires, the CN
BSSAP module processes the overload messages from the BSC, and the
congestion level increases.Timer 206116
Macro Name of Timer

mbTidINTC

Timer Name

G_BSSAP Congest Long

Value Range

0~86400000ms

Default Duration
12-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

30000ms

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN BSSAP module receives an
Over Load message from the BSC, it starts this timer. Before this timer expires, if
the CN BSSAP module has not received an overload message from the BSC, the
CN BSSAP module considers that the congestion level in the BSC decreases.

12.6 Timer 206119


Macro Name of Timer

mbTidBSSAPRELEASE

Timer Name

G_BSSAP Wait For ReleaseCmp

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

When the A interface is released, after the CN BSSAP module sends a "Clear
Command" message, it starts this timer, and waits for a "Clear Complete" message
from the BSC. If this timer expires, the CN BSSAP module resends the "Clear
Command" message for n (default value of the system) times. On the Nth expiry of
this timer, the CN BSSAP module forcibly releases the local resources.

12.7 Timer 206120


Macro Name of Timer

12-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 12 Timers Related with G_BSSAP Module

mbTidBSSAPCONNECT

Timer Name

G_BSSAP Wait For CC

Value Range

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

During the handover, the CN BSSAP module needs to establish the A-interface
connection at first, and then sends A-interface data packets on the connection. After
sending a request for establishing an SCCP connection to the new BSC, the CN
BSSAP module starts this timer, and waits for a connection acknowledgement
message from the BSC. If this timer expires, the CN BSSAP module resends the
request for n (default value of the system) times. On the Nth expiry of this timer, the
CN BSSAP module considers the handover fails and performs the related
processing.

12.8 Timer 206121


Macro Name of Timer

mbTidASSIGNMENT

Timer Name

G_BSSAP Wait For AssignRsp

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length


12-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

After sending an "Assignment Request" message, the CN BSSAP starts this timer,
and waits for an "Assignment Complete/Failure" message from the BSC. If this
timer expires, the CN RANAP module tells the MM module to release all resources,
and to end the flow.

12.9 Timer 206122


Macro Name of Timer

mbTidHANDOVER

Timer Name

G_BSSAP Wait For HoAck

Value Range

0~86400000ms
Default Duration
12000ms

Adjustment Step Length

1ms

Flow Description

After sending a "HandOver Request" message, the CN BSSAP module starts this
timer, and waits for a "HandOver Ack/Failure" message from the BSC. If this timer
expires, the CN RANAP module tells the HO module to release all resources, and to
end the flow.

12.10 Timer 206123


Macro Name of Timer

mbTidWaitRelCic

Timer Name

G_BSSAP TidWaitRelCic

12-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 12 Timers Related with G_BSSAP Module

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

Under the 2G TDM call model, when the system releases the resources after a call
ends, the CC/HO module may require to release the A-interface connection at first,
and then to release the A-interface circuit. To ensure that the A-interface circuit can
still be released in exceptional cases, the BSSAP module starts this timer. If this
timer expires, the BSSAP module releases the circuit.

12.11 Timer 206124


Macro Name of Timer

mbTidDualSwitch

Timer Name

G_BSSAP TidDualSwitch

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

After receiving an EV_DH_SIG_DUALSWITCH_IND message from the DH module,


the BSSAP module starts this timer. When this timer is valid, the dual-homing
switching is being performed. To ensure that no call is interrupted, the CN BSSAP
module does not actively initiate the RESET operation. Within the valid duration of

12-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

this timer, the CN BSSAP module performs no operation.

12-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13
Timers Related with G_RANAP
Module

13.1 Timer 206131


Macro Name of Timer

mrTidUNACCESS

Timer Name

G_RANAP SPC UnAccess

Value Range

0~86400000ms

Default Duration
30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for preventing the status of the signaling point being accessible from
jittering. When the RANAP/BSSAP module receives an event of "the peer-end office
is inaccessible" in case that the peer-end office is accessible (which is recorded in
the data area of the office), it starts this timer. After this timer expires, if the office is
still accessible, it is considered that the office enters the status of being stably
accessible; otherwise, it is considered that the office is intermittently connected.

13-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

13.2 Timer 206132


Macro Name of Timer

mrTidACCESS

Timer Name

G_RANAP SPC Access

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

This timer is for preventing the status of the signaling point being accessible from
jittering. When the RANAP/BSSAP module receives an event of "the peer-end office
is inaccessible" in case that the peer-end office is accessible (which is recorded in
the data area of the office), it starts this timer. After this timer expires, if the office is
still inaccessible, it is considered that the office enters the status of being stably
inaccessible; otherwise, it is considered that the office is intermittently disconnected.

13.3 Timer 206133


Macro Name of Timer

mrTidRESET_CS_R

Timer Name

G_RANAP RNC CS Reset

Value Range

0~86400000ms

Default Duration

5000ms

13-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

Adjustment Step Length

1ms

Flow Description

After receiving a "CS Reset" message, the CN RANAP module starts this timer.
After this timer expires, the CN RANAP module sends a "Reset Ack" message.
Within the valid duration of this timer, the system resets the resources.

13.4 Timer 206134


Macro Name of Timer

mrTidRESET_PS_R

Timer Name

G_RANAP RNC PS Reset

Value Range

0~86400000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

After receiving a "PS Reset" message, the CN RANAP module starts this timer.
After this timer expires, the CN RANAP module sends a "Reset Ack" message.
Within the valid duration of this timer, the system resets the resources.

13.5 Timer 206135


Macro Name of Timer

mrTidRESET_CS_S

Timer Name

G_RANAP CN CS Reset

13-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

After sending a "CS Reset" message, the CN RANAP module starts this timer. If this
timer expires, the CN RANAP module resends the "CS Reset" message for n times
("MSC Reset Times" configured in the safety variable configuration of the network
management system). If the CN RANAP module still does not receive a response
message after resending "CS Reset" message for n times, the CN RANAP module
considers the reset has been completed, and performs the related processing. The
system enters the serving status, and services can be accessed.

13.6 Timer 206136


Macro Name of Timer

mrTidRESET_PS_S

Timer Name

G_RANAP CN PS Reset

Value Range

0~86400000ms

Default Duration

20000ms

Adjustment Step Length

1ms

Flow Description

After sending a "PS Reset" message, the CN RANAP module starts this timer. If this
timer expires, the CN RANAP module resends the "PS Reset" message for n

13-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

(default value of the system) times. If the CN RANAP module still does not receive a
response message after resending "CS Reset" message for n times, the CN
RANAP module considers the reset has been completed, and performs the related
processing. The system enters the serving status, and services can be accessed.

13.7 Timer 206137


Macro Name of Timer

mrTidRESETRESOURCE_CS

Timer Name

G_RANAP TidRESETRESOURCE_CS

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After sending a "CS Reset Resource" message, the CN RANAP module starts this
timer. If this timer expires, the CN RANAP module ends the flow. The CN RANAP
module considers that the resources have been reset and performs the related
processing.

13.8 Timer 206138


Macro Name of Timer

mrTidRESETRESOURCE_PS

Timer Name

G_RANAP TidRESETRESOURCE_PS

Value Range

0~86400000ms
13-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After sending a "PS Reset Resource" message, the CN RANAP module starts this
timer. If this timer expires, the CN RANAP module ends the flow. The CN RANAP
module considers that the resources have been reset and performs the related
processing.

13.9 Timer 206139


Macro Name of Timer

mrTidIGOC_CS

Timer Name

G_RANAP CS Congest Ignore

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN RANAP module receives an
Over Load message from the RNC CS domain, it starts this timer. Before this timer
expires, all the overload messages from the RNC are ignored. After this timer
expires, the CN RANAP module processes the overload messages from the RNC,
and the congestion level increases.

13-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

13.10 Timer 206140


Macro Name of Timer

mrTidIGOC_PS

Timer Name

G_RANAP TidIGOC_PS

Value Range

0~86400000ms

Default Duration

60000ms

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN RANAP module receives an
Over Load message from the RNC PS domain, it starts this timer. Before this
timer expires, all the overload messages from the RNC are ignored. After this timer
expires, the CN RANAP module processes the overload messages from the RNC,
and the congestion level increases.

13.11 Timer 206141


Macro Name of Timer

mrTidINTC_CS

Timer Name

G_RANAP TidINTC_CS

Value Range

0~86400000ms

Default Duration

30000ms

13-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN RANAP module receives an
Over Load message from the RNC CS domain, it starts this timer. Before this timer
expires, if the CN has not received an overload message from the RNC, the
congestion level decreases (CS).

13.12 Timer 206142


Macro Name of Timer

mrTidINTC_PS

Timer Name

G_RANAP TidINTC_PS

Value Range

0~86400000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

When no congestion occurs in the system, after the CN RANAP module receives an
Over Load message from the RNC PS domain, it starts this timer. If the CN has
not received an overload message from the RNC before this timer expires, the
congestion level decreases (PS).

13.13 Timer 206145


Macro Name of Timer

mrTi dIURELEASE

Timer Name
13-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

G_RANAP IU Release

Value Range

0~86400000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

After sending an "IU Release Command" message, the CN RANAP module starts
this timer, and waits for an "IU Release Complete" message from the RNC. If this
timer expires, the CN RANAP module resends the "IU Release Command"
message for n (default value of the system) times. If the CN RANAP module still
does not receive a response message after resending "CS Reset" message for n
times, the CN RANAP module forcibly releases the local resources.

13.14 Timer 206146


Macro Name of Timer

mrTidIUCONNECT

Timer Name

G_RANAP IU Connection

Value Range

0~86400000ms

Default Duration

8000ms

Adjustment Step Length

1ms

Flow Description

After receiving a Relocation Request and sending a SCCP connection request, the

13-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

CN RANAP module starts this timer, and waits for a connection acknowledgement
message from the RNC. If this timer expires, the CN RANAP module resends the
connection request for n (default value of the system) times. On the Nth expiry of
this timer, the CN BSSAP module considers that the connection fails to be
established, and performs the related processing.

13.15 Timer 206147


Macro Name of Timer

mrTidASSIGNMENT

Timer Name

G_RANAP RAB Assignment

Value Range

0~86400000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

After sending a "RAB Assignment Request" message, the CN RANAP module starts
this timer, and waits for a "RAB Assignment RESPONSE" message from the RNC.
If this timer expires, the CN RANAP module tells the MM module to release all
resources, and to end the flow.

13.16 Timer 206148


Macro Name of Timer

mrTidRELOCATION

Timer Name

G_RANAP Relocation

Value Range

13-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

0~86400000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

After sending a "Relocation Request" message, the CN RANAP module starts this
timer, and waits for a "Relocation Ack/Failure" message from the RNC. If this timer
expires, the CN RANAP module tells the HO module to release all resources, and to
end the flow.

13.17 Timer 206150


Macro Name of Timer

mrTidMSROTATE

Timer Name

G_RANAP Slave To Master

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the active/standby switching of the MP boards, after the standby board
receives a message, the CN RANAP module starts this timer. If the CN RANAP
module receives a message of the active board being successfully switched to the
standby one, the standby board is switched to the active one, and the CN RANAP
module stops this timer. If this timer expires, the quasi active board is successfully
switched to the active server from the standby one.

13-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

13.18 Timer 206151


Macro Name of Timer

mrTidCOMMRESET

Timer Name

G_RANAP Comm Reset

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

After the communication between the active MP board and the standby on is
recovered, the RANAP process on the standby MP board sends an
mrSynchrDataReqEvent message to that on the active MP board, requesting to
synchronize the data requiring backing up. At the same time, the RANAP module
starts this timer with the protection duration as 3s. If this timer expires, the data
synchronization is re-initiated. After the data synchronization ends, the RANAP
module stops this timer. If the RANAP module has received an
mrBackupSynchrDataEvent or mrCallMasterSynDataEndEvent message before this
timer expires, it stops this timer.

13.19 Timer 206152


Macro Name of Timer

mrTidSessionStart

Timer Name

G_RANAP TidSessionStart

Value Range

0~86400000ms

13-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 13 Timers Related with G_RANAP Module

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the PS MBMS service, after the RANAP module receives a


grSessionStartEvent message from the PS MBMS, it sends an
mrMBMSSessionStart_M message to the RNC, and starts this timer. If the RANAP
module has not received a response from the RNC before this timer expires, it
releases the IU data area, and sends a grSessionStartFailureEvent message
(indicating failure) to the MBMS.

13.20 Timer 206153


Macro Name of Timer

mrTidSessionStop

Timer Name

G_RANAP TidSessionStop

Value Range

0~86400000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the PS MBMS service, after the RANAP module receives a


grSessionStopEvent message from the PS MBMS, it sends an
mrMBMSSessionStop_M message to the RNC, and starts this timer. If the RANAP
module has not received a response from the RNC before this timer expires, it
releases the IU data area, and sends a grSessionStopFailureEvent message
(indicating failure) to the MBMS.

13-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

13.21 Timer 206154


Macro Name of Timer

mrTidDualSwitch

Timer Name

G_RANAP TidDualSwitch

Value Range

0~86400000ms

Default Duration

30000ms

Adjustment Step Length

1ms

Flow Description

After receiving an EV_DH_SIG_DUALSWITCH_IND message from the DH module,


the RANAP module starts this timer. When this timer is valid, the dual-homing
switching is being performed. To ensure that no call is interrupted, the CN BSSAP
module does not actively initiate the RESET operation. If the RANAP module has
not received a message indicating whether the link is connected before this timer
expires, it does not initiate the RESET operation.

13-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 14
Timers Related with G_DH Module

14.1 Timer 206197


Macro Name of Timer

DH_TIMERLEN_DOMAINLINKOP

Timer Name

DH Domain Link Operate

Value Range

8000~18000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

During the dual-homing status transformation process, when the inter-office link is
operated, the DH module starts this timer, and waits for the operation result
response. If the DH module has not received a response before this timer expires, it
reports the notification to make the link manually maintained and to keep the service
in the normal status. If the DH module has received a response, it stops this timer.

14.2 Timer 206198


Macro Name of Timer

14-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

DH_TIMERLEN_QUERYMGWREG

Timer Name

DH Query MGW Register

Value Range

3000~10000ms

Default Duration

5000ms

Adjustment Step Length

1ms

Flow Description

In the following two cases, the DH module starts this timer.


Case 1: When the dual-homing standby domain enters the temporary
status, the DH module starts this timer. Within a timer duration, if any
MGW registers to the standby domain, the standby domain is switched
to the active one.
Case 2: When it is found that the heartbeat is unavailable in the
dual-homing active domain, the DH module starts this timer. Within a
timer duration, if no MGW registers to the active domain, the active
domain is switched to the standby one.

14.3 Timer 206199


Macro Name of Timer

DH_TIMERLEN_START

Timer Name

DH Start State

Value Range

180000600000ms

Default Duration

300000ms

14-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 14 Timers Related with G_DH Module

Adjustment Step Length

1ms

Flow Description

When the MSCS enters the Start status after dual-homing power-on, the DH
module starts this timer, and waits for the heartbeat association to be established.
After this timer expires, the DH module starts to perform the status switching of the
dual-homing domains. If the heartbeat association has been successfully
established before this timer expires, the DH module stops this timer, and performs
status switching of the dual-homing domains as required.

14.4 Timer 206200


Macro Name of Timer

DH_TIMER_SWITCH

Timer Name

DH Switch Monitor

Value Range

60000~900000ms

Default Duration

420000ms

Adjustment Step Length

1ms

Flow Description

When the dual-homing work domains are switched with the dynamic management
tool of the network management system being used, the DH module starts this timer.
Before this timer expires, the DH module continually reports the status of each office
during the switching of the work domains. After this timer expires, the switching
guard ends. If the switching has normally ended before this timer expires, the DH
module stops this timer.

14-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


14-4

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15
Timers Related with BICC Module

15.1 Timer 208402


Macro Name of Timer

BICC_T5

Timer Name

BICC_T5

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-1

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

When a call is released, after SP A sends a REL message, it starts both short timer
BICC_T1 and long timer BICC_T5, and waits for a RLC message from SP B. After
T5 expires, SP A stops T1, and sends a RSC message. This timer is long timer T5.

15.2 Timer 208403


Macro Name of Timer

BICC_T6

Timer Name

BICC_T6

Value Range

0~90000ms

Default Duration

90000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-2

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

After a call enters stable status (the call is answered), SP A receives a SUS
(suspension) message from SP B. Then SP A starts this timer, and waits for a RES
(restoration) message from SP B. After receiving the RES message from SP B, SP
A stops this timer.

15.3 Timer 208404


Macro Name of Timer

BICC_T7

Timer Name

BICC_T7

Value Range

0~30000ms

Default Duration
30000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-3

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

SPA SPB

IAM
T7

ACM

ANM

REL

RLC

SP A originates a call to SP B by sending an IAM or SAM (not shown in the above


figure) message to SP B. Then it starts this timer, and waits for an ACM message
from SP B. After SP A receives the ACM message from SP B, it stops this timer. The
subsequent steps are the same with those of the basic call flow.

15.4 Timer 208405


Macro Name of Timer

BICC_T8

Timer Name

BICC_T8

Value Range

0~15000ms

Default Duration

15000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-4

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

SPA SPB

IAM

COT

ACM
ANM

REL

SP B originates a call to SP A by sending an IAM message to SP A. After receiving


the IAM message indicating that the forward bearer is not established, SP A starts
this timer, and waits for a COT message. After receiving the COT message, SP A
stops this timer. The subsequent steps are the same with those of the basic call
flow.

15.5 Timer 208406


Macro Name of Timer

BICC_T9

Timer Name

BICC_T9

Value Range

0~120000ms

Default Duration

120000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-5

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

SPA SPB

IAM

ACM
T9

ANM

REL

RLC

SP A originates a call to SP B by sending an IAM message to SP B. After receiving


an ACM message, SP A starts this timer, and waits for an ANM message from SP B.
After SP B returns the ANM message to SP A, SP A stops this timer. The
subsequent steps are the same with those in the message release flow after the
call.

15.6 Timer 208407


Macro Name of Timer

BICC_T17

Timer Name

BICC_T17

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-6

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

SPA SPB

RSC
T16
RSC
T17

RSC

RLC

After sending a RSC message to SP B, SP A starts both long timer T17 and short
timer T16, and waits for a RLC message from SP B. After T17 expires, SP A stops
T16. This timer is long timer T17.

15.7 Timer 208408


Macro Name of Timer

BICC_T19

Timer Name

BICC_T19

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-7

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

SPA SPB

CGB
T18

CGB
T19

CGB

CGBA

After sending a CGB message to SP B, SP A starts both long timer T19 and short
timer T18, and waits for a CGBA message from SP B. After T19 expires, SP A stops
T18. This timer is long timer T19.

15.8 Timer 208409


Macro Name of Timer

BICC_T21

Timer Name

BICC_T21

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-8

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

SP A SP B

CGU

T20
CGU
T21

CGU

CGUA

After sending a CGU message to SP B, SP A starts both long timer T21 and short
timer T20, and waits for a CGUA message from SP B. After T21 expires, SP A stops
T20. This timer is long timer T21.

15.9 Timer 208410


Macro Name of Timer

BICC_T23

Timer Name

BICC_T23

Value Range

0~900000ms

Default Duration

300000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-9

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

SP A SP B

T22 GRS

GRS
T23

GRS

GRA

After sending a GRS message to SP B, SP A starts both long timer T23 and short
timer T22, and waits for a GRA message from SP B. After T23 expires, SP A stops
T22. This timer is long timer T23.

15.10 Timer 208411


Macro Name of Timer

BICC_T33

Timer Name

BICC_T33

Value Range

0~15000ms

Default Duration

12000ms

Adjustment Step Length

1ms

Flow Description

The service flow is shown in the figure below.

15-10

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

SP A SP B

IAM

INR

T33
INF

ACM

ANM

1. After receiving an IAM message, SP B finds no calling number, so it


requests for the calling number.
2. SP B sends an INR message of requesting for the calling number, and
starts this timer.
3. After receiving the INR message, SP A fills the calling number in an INF
message.
4. After receiving the INF message, SP B stops this timer. The flow of
requesting for the calling number ends. The subsequent steps are the
same with those of the basic call flow.

15.11 Timer 208412


Macro Name of Timer

BICC_T34

Timer Name

BICC_T34

Value Range

0~4000ms

Default Duration

2000ms

Adjustment Step Length

15-11

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

1ms

Flow Description

After receiving a signaling message carrying a segmentation indicator, the BICC


module starts this timer, and waits for an SGM (segmentation) message.

15.12 Timer 208413


Macro Name of Timer

BICC_TWtSetupAck

Timer Name

BICC_TWtSetupAck

Value Range

0~5000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


During an incoming call, after the BICC module sends an L3L4_SETUP_IND
message to the GCM module, it starts this timer, and waits for an
L4L3_SETUP_ACK message from the GCM module.

15.13 Timer 208414


Macro Name of Timer

BICC_Treass

Timer Name

BICC_Treass

Value Range
15-12

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

0~18000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

The BICC module receives an APM message, and decodes the APP parameter in
this message. If the BICC module finds a segmentation indictor in the APP
parameter, it starts this timer, and waits for the subsequent APP messages.

15.14 Timer 208415


Macro Name of Timer

BICC_SetUp

Timer Name

BICC_SetUp

Value Range

0~10000ms

Default Duration

10000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


During an outgoing call, after the BICC module receives an L4L3_TPCALL_ACK
message from the GCM module, it starts this timer, and waits for an
L4L3_SETUP_IND message from the GCM module.

15-13

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


ZXWN MSCS Timer Reference

15.15 Timer 208416


Macro Name of Timer

BICC_TWtTpcallAck

Timer Name

BICC_WtTpRsp

Value Range

0~5000ms

Default Duration

2000ms

Adjustment Step Length

1ms

Flow Description

This timer is for interaction between internal modules.


During an outgoing call, after the BICC module receives a message from the DB, it
sends an L3L4_TPCALL_IND message to the GCM module. Then it starts this timer,
and waits for an L4L3_TPCALL_AC message from the GCM module.

15.16 Timer 208417


Macro Name of Timer

BICC_TWtRelAck

Timer Name

BICC_TWtRelAck

Value Range

0~5000ms

Default Duration

2000ms

Adjustment Step Length

15-14

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


Chapter 15 Timers Related with BICC Module

1ms

Flow Description

This timer is for interaction between internal modules.


During the course of call release, after the BICC module sends an L3L4_ RELEASE
_IND message to the GCM module, it starts this timer, and waits for an
L4L3_RELEASE_ACK message from the GCM module.

15-15

SJ-20100914141201-002|2010-10-30(R1.0) ZTE Proprietary and Confidential


15-16

SJ-20100914141201-031|2010-10-30(R1.0) ZTE Proprietary and Confidential


Index

BICC module II, 2-39, 3-14, 15-12, 15-13, G_RANAP module II


15-14, 15-15 G_TCAP module II
G_Common module I, 5-1, 5-2 G_TM module II
G_DH module II G_VLRMAP module II
G_GSMSSF module II GMSC module I, 3-2, 3-3, 3-4, 3-5, 3-6, 3-14,
G_HO module I 7-9
G_MCC module I MM module I, 1-1, 1-2, 1-3, 1-4, 1-5, 1-6, 1-7,
G_MCF module I 1-8, 1-9, 1-10, 1-11, 1-12, 1-13, 1-14, 1-15,
G_MSCMAP module II 7-3, 8-12, 8-15, 8-16, 8-17, 12-6, 13-10