You are on page 1of 10

16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

English(US) Submitarequest Signin

SmartPTTTechnicalSupportCenter>KnowledgeArticles>All Search

Emergencymodesettings

TableofContents

Introduction

1.Emergencymodesettingsofthesubscriberradio

1.1.EmergencymodesettingsofthesubscriberradiowhenworkingwithControlstationsorIPSiteConnectNetworks

1.2.EmergencymodesettingsofthesubscriberradiowhenworkingwithCapacityPlusSystems

2.ControlStationConfiguration

2.1.ControlStationconfiguration(Controlstationsystem)

2.2.ControlStationconfigurationforCapacityPlussystem

3.SmartPTTServerConfigurationwhenworkingwithIPSiteConnectNetworks

4.HowtoexitEmergencyMode

Introduction

MOTOTRBOprovidestheabilityforaradiouserindistresstosendaconfirmedemergencyalarmmessage,andemergencyvoicetoauserona
supervisoryradio.TheemergencyalarmmessagecontainstheindividualradioIDoftheinitiator.Uponreceptionofanemergencyalarm,the
supervisorreceivesaudibleandvisualindicationsoftheemergencyandtheinitiatingradioIDaredisplayed.Dependingonconfiguration,emergency
voicemayfollowbetweentheinitiatorandthesupervisor.Oncethesupervisorhandlestheemergencysituation(i.e.solvestheproblem),heclears
theemergencyonthesupervisorradio.Oncetheinitiatorclearshisemergencyontheinitiatorradio,theemergencyisconsideredover.

1.Emergencymodesettingsofthesubscriberradio
ToconfigureEmergencyModeoption,itsnecessarytomakesomechangesinconfigurationsofcontrolstationandsubscriberradiosradiosusing
theMOTORBOCPSapplication.

Toconfiguresubscriberradio,usetheparagraph1.1or1.2dependingonsystemconfiguration.

1.1.EmergencymodesettingsofthesubscriberradiowhenworkingwithControlstationsorIPSiteConnectNetworks

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 1/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

InconfigurationsofsubscriberradiointheButtonstabintheRadioButtonsfieldspecifythebuttonwhichwillturnEmergencyAlarmonandturn
EmergencyAlarmoff.

EachmobileradiocanprogramtheEmergencyAlarmtoanyoftheprogrammablebuttons,whereasfortheportableradiotheEmergencyAlarmcan
onlybeprogrammedtotheorangebutton.Pressingtheemergencybuttoncausestheradiotoenteremergencymode,andbeginitsemergency
process.

WhenauserpressestheEmergencybutton,theradiogivesaudibleandvisualindicationstoshowthatithasenteredemergencymode.

Forportableradio:

Formobileradio:

2.InconfigurationsofsubscriberradiointheDigitalEmergency(SignalingSystems)tabspecifyoneofthealarmtypes:

RegularTheradiotransmitsanalarmsignalandprovidesaudioandvisualindicationthatitisinEmergencymode.

SilentTheradiotransmitsanalarmsignalbutgivesnoaudioorvisualindicationthatitisinEmergencymode.Inaddition,itwillnotunmutetoany
receivedaudio.

Silentw/VoiceTheradiotransmitsanalarmsignalbutgivesnoaudioorvisualindicationthatitisinEmergencymode.Theradiothenunmutesto
qualifiedchannelactivity

3.Definebehavioroftheradiowhentheradioemergencybuttonispressed:

EmergencyAlarmTheradiosendsanemergencyalarmandexitstheemergencymode.Thisalarmisanonvoicesignalthattriggersanalert
indicationonanotherradio.

EmergencyAlarmw/CallAnemergencyalarmissent,afterwhichanemergencycallcanbetransmittedbypressingthePushToTalk(PTT)
button.

EmergencyAlarmw/VoicetoFollowAnemergencyalarmissentandthemicrophoneisactivatedforanemergencycall.Voiceistransmitted
withouttheneedtopressthePTTbutton.

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 2/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

4.Choosethechannelusedfordigitalemergencyalarmorvoice.AnysinglesitedigitalchannelmaybesetastheRevertChannel,includingthe
channelindicatedbytheradiochannelselector.

5.IntheChannelstabselectcheckboxesEmergencyAlarmIndicationandEmergencyCallIndicationforeachchannelonwhichthesubscriber
radioshouldhavepossibilitytouseEmergencyMode.SpecifytheEmergencySystemwhichisusedonthischannel.

EmergencyAlarmIndicationDeterminesifaudioandvisualindicationisgivenbytheradiowhenanemergencyalarmisreceived.Ifthecheckboxis
unchecked,theradiodisplaysnothingwhenitreceivesanemergencyalarm.

EmergencyAlarmAckDeterminesiftheradioisallowedtoacknowledgeanemergencyalarm.Itisrecommendedthatonlyasingleradioonthe
groupbeprogrammedtoacknowledgeemergencyalarms.Thischeckboxshouldtypicallyonlybecheckedonthedispatchersradio.

EmergencyCallIndicationDeterminesifavisualindicationisgivenbytheradiowhenanemergencycallisreceived.

EmergencySystemdeterminestheEmergencySystem,whichisprogrammedintheDigitalEmergencytab.

ContactNameAtleastonechannelmusthaveaGroupCallasitsContactName.

1.2.EmergencymodesettingsofthesubscriberradiowhenworkingwithCapacityPlusSystems

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 3/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

1.ToconfigureEmergencyModeofCapacityPlussystems,specifytheAlarmType(Regular,Silent,Silentw/Voice)andModeoftheradios
behaviorwhentheradio'semergencybuttonispressed(EmergencyAlarm,EmergencyAlarmw/Call,EmergencyAlarmw/VoicetoFollow)In
configurationsofsubscriberradioinCapacityPlusEmergencytab.IntheContactfieldspecifytheGroupwhichreceivestheemergencyalarm.

2.SelectcheckboxEmergencyAlarmIndicationandEmergencyCallIndicationonthecreatedCapacityPlusPersonalityChannel.Specifythe
EmergencySystemwhichisusedonthischannel.

2.ControlStationConfiguration
2.1.ControlStationconfiguration(Controlstationsystem)

Warning!Themobileradiowhichisprogrammedtoacknowledgeemergencyalarmsmustbedisplaymobileradio(DM36XX).

Note:EmergencymodeconfigurationofControlstationsofCapacityPlusSystemsisdescribedinparagraph4ofthisdocument.

1.SpecifyoneofthesignaltypesintheDigitalEmergency(SignalingSystems)tab:

RegularTheradiotransmitsanalarmsignalandprovidesaudioandvisualindicationthatitisinEmergencymode.
SilentTheradiotransmitsanalarmsignalbutgivesnoaudioorvisualindicationthatitisinEmergencymode.Inaddition,itwillnotunmute
toanyreceivedaudio.

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 4/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

Silentw/VoiceTheradiotransmitsanalarmsignalbutgivesnoaudioorvisualindicationthatitisinEmergencymode.Thentheradio
unmutestoqualifiedchannelactivity.

2.Specifytheradiosbehaviorwhentheradio'semergencybuttonispressed:

EmergencyAlarmTheradiosendsanemergencyalarmandexitstheemergencymode.Thisalarmisanonvoicesignalthattriggersan
alertindicationonanotherradio.
EmergencyAlarmw/CallAnemergencyalarmissent,afterwhichanemergencycallcanbetransmittedbypressingthePushToTalk(PTT)
button.
EmergencyAlarmw/VoicetoFollowAnemergencyalarmissentandthemicrophoneisactivatedforanemergencycall.Voiceistransmitted
withouttheneedtopressthePTTbutton.

3.Choosethechannelwhichisusedfordigitalemergencyalarmorvoice.AnysinglesitedigitalchannelmaybesetastheRevertChannel,
includingthechannelindicatedbytheradio'schannelselector.

4.IntheChannelstabselectcheckboxesEmergencyAlarmIndication,EmergencyAlarmAckandEmergencyCallIndicationforeachchannel
onwhichthesubscriberradioshouldhavepossibilitytouseEmergencyMode.SpecifytheEmergencySystemwhichisusedonthechannel.

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 5/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

2.2.ControlStationconfigurationforCapacityPlussystem

Warning!Themobileradiowhichisprogrammedtoacknowledgeemergencyalarmsmustbedisplaymobileradio(DM36XX).

1.ToconfigureEmergencyModeofCapacityPlussystems,specifytheAlarmType(Regular,Silent,Silentw/Voice)andModeoftheradios
behaviorwhentheradio'semergencybuttonispressed(EmergencyAlarm,EmergencyAlarmw/Call,EmergencyAlarmw/VoicetoFollow)in
configurationsofsubscriberradioinCapacityPlusEmergencytab.IntheContactfieldspecifytheGroupwhichreceivestheemergencyalarm.

2.IntheChannelstabselectcheckboxesEmergencyAlarmIndication,EmergencyAlarmAckandEmergencyCallIndicationforeachchannel
onwhichthesubscriberradioshouldhavepossibilitytouseEmergencyMode.SpecifytheEmergencySystemwhichisusedonthechannel.

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 6/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

3.SmartPTTServerConfigurationwhenworkingwithIPSiteConnect
Networks
IfMOTOTRBOIPSiteConnectNetworksareused,thenbesidessubscriberradioconfigurationSmartPTTRadioservermustbeconfiguredaswell.

SelectcheckboxEmergencyAlarmConfirmationforbothslots(SmartPTTServerConfiguration>IPSiteConnect1>Slot1(Slot2))ifEmergency
willbeusedonbothslots.

EmergencyAlarmConfirmationdeterminesiftheemergencyalarmisallowedtobeacknowledgedbySmartPTTRadioserver.

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 7/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

4.HowtoexitEmergencyMode
ThenameofControlStationintheEmergencymodeishighlightedwithredcolorontheSmartPTTDispatcherConsole.

Toexitemergencymode:

1.selectthecontrolstationwhichisinemergencymodeandrightclickonit
2.clickonthebuttonExitEmergencyMode

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 8/10
16/9/2016 EmergencymodesettingsSmartPTTTechnicalSupportCenter

Relatedarticles

1.7.IPSiteConnectCodeplugsConfiguration.SubscriberRadios.

EnhancedGPS

DynamicMixedMode(DMM)

CapacityPlusDeploymentGuide(MOTOTRBO+SmartPTT)

Recentlyviewedarticles

DynamicMixedMode(DMM)

Wasthisarticlehelpful?

1outof1foundthishelpful

Havemorequestions?Submitarequest

http://support.smartptt.com/hc/enus/articles/200241248Emergencymodesettings 9/10