Professional Documents
Culture Documents
INDEX
1. INTRODUCTION .................................................................................................................................. 3
2. APPLICABLE STANDRDS/REFERENCES................................................................................................ 3
3. MATERIAL PROPERTIES AND CONSTANTS .......................................................................................... 3
4. DESIGN OF ANCHOR BLOCK ............................................................................................................... 5
ANNEXURE-I PIPING LAYOUT ............................................................................................................... 8
ANNEXURE-II STRESS ANALYSIS REPORT ............................................................................................. 9
ANNEXURE-III SOIL REPORT ............................................................................................................... 10
NEW FLOWLINES FOR 5 EXTG. INJECTION WELLS, 1 NEW SOURCE CONTRACT NUMBER : 15050923
PROJECT: WELL & REPLACEMENT OF 19 EXTG.BRACKISH WATER FLOWLINES
WK PLUS EMERGENCY BRACKISH WATER LINE TO NTF PROJECT NUMBER : EF/1874
DOCUMENT NUMBER: 15050923-A-C-5003 REV B Page 3 of 10 DATE: 06.01.2016
1. INTRODUCTION:
The design report indicates the calculation of 8-AW-5017-F30A pipeline anchor block at MWIP area
and MN-47 well head area for the New flow lines for 5 existing injection wells, 1 new source well &
replacement of 19 existing brackish water flow lines WK plus emergency brackish water line to NTF
project.
2. APPLICABLE STANDARDS/REFERENCES:
1. ACI 318-11, Building code requirements for Reinforced Concrete
3. ASCE 7.05 - Minimum design loads for buildings and other structures
5. Foundation analysis & design by Bowles, fourth edition, published by McGraw Hill
REINFORCING STEEL:
Modulus of Elasticity (Es) = 2 x 105 MPa
= 29 x 106 psi
= 414 MPa
STRUCTURAL STEEL:
Modulus of Elasticity (Es) = 2 x 105 MPa
Z Z'
X'
ANCHOR POINT
1 2
Anchor flange
0.75 m
Z'
2m
0.75 m
4 3
3m Pipe line axis X'
Plan of anchor block
Ground level NGL 178.4
1.358 m
3m
Top of Anchor block
1.5 m
NGL 178.4
Zero pressure at top
1.36 m
3.33x18x1.36= 0.3x18x1.36=
82 kN/m^2 Pressure at top of anchor block 7.3 kN/m^2
Force excerted on anchor block base due to active earth pressure along X- = (7.34x2x1.5)+(0.5x(15.44-7.34)x2x1.5)
direction = 34.17 kN
Force excerted on anchor block base due to passive earth pressure along X- = (81.52x2x1.5)+(0.5x(171.43-81.52)x2x1.5)
direction = 379.43 kN
Overturning moment on anchor block bottom due to active earth pressure = (7.34x2x1.5x1.5/2)+(0.5x(15.44-7.34)x2x1.5x1.5/3)
along X-direction (Moment about Z direction) = 22.59 kN.m
Overturning moment on anchor block bottom due to passive earth pressure = (81.52x2x1.5x1.5/2)+(0.5x(171.43-81.52)x2x1.5x1.5/3)
along X-direction (Moment about Z direction) = 250.85 kN.m
Reinforcement calculation:
Reinforcement calculation for anchor block outer skin:
Minimum steel required in kg per metre cube of concrete for block = 25 kg/m3
foundation in static case (Distributed in all faces of block foundation)
Length of the anchor block = 3 m
Width of the anchor block = 2 m
Thickness of the anchor block = 1.5 m
Concrete Volume of the anchor block = 3 x 1.5 x 2
= 9 m3
Minimum steel required = 25 x 9
= 225 kg
Assume diameter of reinforcement for all faces = 12 mm = 0.012 m
Assume spacing of reinforcement for all faces = 175 mm = 0.175 m
Clear cover to reinforcement for all faces = 75 mm = 0.075 m
Length wise reinforcement in top and bottom face of anchor block = 0.007 m3
Width wise reinforcement in top and bottom face of anchor block = 0.007 m3
Length wise reinforcement in both side face of anchor block = 0.006 m3
Width wise reinforcement in both side face of anchor block = 0.004 m3
Vertical reinforcement in both side face of anchor block-length face = 0.005 m3
Vertical reinforcement in both side face of anchor block-width face = 0.004 m3
Total volume of provided steel = 0.033 m3
Unit weight of reinforcement steel = 7850 kg/m3
Total weight of provided steel = 259.05 kg > 225 kg
NEW FLOWLINES FOR 5 EXTG. INJECTION WELLS, 1 NEW SOURCE CONTRACT NUMBER : 15050923
PROJECT: WELL & REPLACEMENT OF 19 EXTG.BRACKISH WATER FLOWLINES
WK PLUS EMERGENCY BRACKISH WATER LINE TO NTF PROJECT NUMBER : EF/1874
DOCUMENT NUMBER: 15050923-A-C-5003 REV B Page 7 of 10 DATE: 06.01.2016
Z Z'
X'
ANCHOR POINT
1 2
Anchor flange
0.75 m
Z'
2m
0.75 m
4 3
3m Pipe line axis X'
Plan of anchor block
Ground level NGL 187.4
1.158 m
3m
Top of Anchor block
1.5 m
NGL 187.4
Zero pressure at top
1.16 m
3.33x18x1.16= 0.3x18x1.16=
70 kN/m^2 Pressure at top of anchor block 6.3 kN/m^2
Force excerted on anchor block base due to active earth pressure along X- = (6.26x2x1.5)+(0.5x(14.36-6.26)x2x1.5)
direction = 30.93 kN
Force excerted on anchor block base due to passive earth pressure along X- = (69.53x2x1.5)+(0.5x(159.44-69.53)x2x1.5)
direction = 343.46 kN
Overturning moment on anchor block bottom due to active earth pressure = (6.26x2x1.5x1.5/2)+(0.5x(14.36-6.26)x2x1.5x1.5/3)
along X-direction (Moment about Z direction) = 20.16 kN.m
Overturning moment on anchor block bottom due to passive earth pressure = (69.53x2x1.5x1.5/2)+(0.5x(159.44-69.53)x2x1.5x1.5/3)
along X-direction (Moment about Z direction) = 223.88 kN.m
Reinforcement calculation:
Reinforcement calculation for anchor block outer skin:
Minimum steel required in kg per metre cube of concrete for block = 25 kg/m3
foundation in static case (Distributed in all faces of block foundation)
Length of the anchor block = 3 m
Width of the anchor block = 2 m
Thickness of the anchor block = 1.5 m
Concrete Volume of the anchor block = 3 x 1.5 x 2
= 9 m3
Minimum steel required = 25 x 9
= 225 kg
Assume diameter of reinforcement for all faces = 12 mm = 0.012 m
Assume spacing of reinforcement for all faces = 175 mm = 0.175 m
Clear cover to reinforcement for all faces = 75 mm = 0.075 m
Length wise reinforcement in top and bottom face of anchor block = 0.007 m3
Width wise reinforcement in top and bottom face of anchor block = 0.007 m3
Length wise reinforcement in both side face of anchor block = 0.006 m3
Width wise reinforcement in both side face of anchor block = 0.004 m3
Vertical reinforcement in both side face of anchor block-length face = 0.005 m3
Vertical reinforcement in both side face of anchor block-width face = 0.004 m3
Total volume of provided steel = 0.033 m3
Unit weight of reinforcement steel = 7850 kg/m3
Total weight of provided steel = 259.05 kg > 225 kg
NEW FLOWLINES FOR 5 EXTG. INJECTION WELLS, 1 NEW SOURCE CONTRACT NUMBER : 15050923
PROJECT: WELL & REPLACEMENT OF 19 EXTG.BRACKISH WATER FLOWLINES
WK PLUS EMERGENCY BRACKISH WATER LINE TO NTF PROJECT NUMBER : EF/1874
DOCUMENT NUMBER: 15050923-A-C-5003 REV B Page 8 of 10 DATE: 06.01.2016
Bi-linear X2;
3793 Bi-linear X2;
Bi-linear Y2
1(HYD) 2157 0 -5308 0 0 0
2(OPE) 10164 0 -25054 0 0 0
3(SUS) 1427 0 -3510 0 0 0
MAX 10164/L2 0/L3 -25054/L2
Bi-linear X2;
3800 Bi-linear Z2;
Bi-linear Y2
1(HYD) -11 0 -462 0 0 0
2(OPE) -61 0 -1948 0 0 0
3(SUS) -7 0 -307 0 0 0
MAX -61/L2 0/L1 -1948/L2
Bi-linear X2;
3810 Bi-linear Z2;
Bi-linear Y2
1(HYD) -516 0 -17377 0 0 0
2(OPE) -2857 0 -71085 0 0 0
3(SUS) -338 0 -11562 0 0 0
MAX -2857/L2 0/L1 -71085/L2
Bi-linear X2;
3820 Bi-linear Z2;
Bi-linear Y2
1(HYD) 0 0 14 0 0 0
2(OPE) 184 0 68 0 0 0
3(SUS) 0 0 9 0 0 0
MAX 184/L2 0/L2 68/L2
Bi-linear X2;
Bi-linear Z2;
3830
Bi-linear Y2;
Rigid ANC
1(HYD) -909 -426 109 -22 -120 398
2(OPE) -58629 -1313 253 -371 -819 1227
3(SUS) -505 -270 86 30 -68 253
MAX -58629/L2 -1313/L2 253/L2 -371/L2 -819/L2 1227/L2
Bi-linear X2;
3840 Bi-linear Z2;
Bi-linear Y2
1(HYD) -0 -4 1 0 0 0
2(OPE) -22 -13 2 0 0 0
3(SUS) -0 -3 1 0 0 0
MAX -22/L2 -13/L2 2/L2
580
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: AUG 15, 2015 Time: 11:19
Job:: MN-47B
Licensed To:: GULF SPIC GENERAL TRADING AND CONTRACTING COM
RESTRAINT SUMMARY REPORT: Loads On Restraints
Various Load Cases
Bi-linear X2;
3031 Bi-linear X2;
Bi-linear X2
1(HYD) 768 -1338 744 0 0 0
2(OPE) 1841 -3053 1768 0 0 0
3(SUS) 543 -962 525 0 0 0
MAX 1841/L2 -3053/L2 1768/L2
Bi-linear X2;
3040 Bi-linear X2;
Bi-linear Y2
1(HYD) 70 463 69 0 0 0
2(OPE) 206 1914 216 0 0 0
3(SUS) 44 211 42 0 0 0
MAX 206/L2 1914/L2 216/L2
Bi-linear X2;
3050 Bi-linear X2;
Bi-linear Y2
1(HYD) 1048 -540 1113 0 0 0
2(OPE) 3181 2261 3329 0 0 0
3(SUS) 641 -969 692 0 0 0
MAX 3181/L2 2261/L2 3329/L2
Bi-linear X2;
3060 Bi-linear X2;
Bi-linear Y2
1(HYD) 1 -7 1 0 0 0
2(OPE) 50 -24 50 0 0 0
3(SUS) 1 -4 1 0 0 0
MAX 50/L2 -24/L2 50/L2
Bi-linear X2;
Bi-linear X2;
3070
Bi-linear Y2;
Rigid ANC
1(HYD) 26060 -112 26061 191 -2 -183
581
CAESAR II 2014 Ver.7.00.00.2800, (Build 140416) Date: AUG 15, 2015 Time: 11:19
Job:: MN-47B
Licensed To:: GULF SPIC GENERAL TRADING AND CONTRACTING COM
RESTRAINT SUMMARY REPORT: Loads On Restraints
Various Load Cases
Bi-linear X2;
3080 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 0 -0 0 0 0
2(OPE) -141 0 -141 0 0 0
3(SUS) -0 0 -0 0 0 0
MAX -141/L2 0/L2 -141/L2
Bi-linear X2;
3081 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 -0 -0 0 0 0
2(OPE) -139 -0 -139 0 0 0
3(SUS) -0 -0 -0 0 0 0
MAX -139/L2 -0/L3 -139/L2
Bi-linear X2;
3082 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 -0 -0 0 0 0
2(OPE) -72 -0 -72 0 0 0
3(SUS) -0 -0 -0 0 0 0
MAX -72/L2 -0/L2 -72/L2
Bi-linear X2;
3083 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 -0 -0 0 0 0
2(OPE) -35 -0 -35 0 0 0
3(SUS) -0 -0 -0 0 0 0
MAX -35/L2 -0/L3 -35/L2
Bi-linear X2;
3084 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 -0 -0 0 0 0
2(OPE) -16 -0 -16 0 0 0
3(SUS) -0 -0 -0 0 0 0
MAX -16/L2 -0/L2 -16/L2
Bi-linear X2;
3085 Bi-linear X2;
Bi-linear Y2
1(HYD) -0 -0 -0 0 0 0
2(OPE) -8 -0 -8 0 0 0
3(SUS) -0 -0 -0 0 0 0
NEW FLOWLINES FOR 5 EXTG. INJECTION WELLS, 1 NEW SOURCE CONTRACT NUMBER : 15050923
PROJECT: WELL & REPLACEMENT OF 19 EXTG.BRACKISH WATER FLOWLINES
WK PLUS EMERGENCY BRACKISH WATER LINE TO NTF PROJECT NUMBER : EF/1874
DOCUMENT NUMBER: 15050923-A-C-5003 REV B Page 10 of 10 DATE: 06.01.2016