You are on page 1of 3

EXTRACTIONPLANTPT.

PERTASAMTANGAS
MAINTENANCEREPORT
25January2017
I.SKGX
No. Equipment RH Activities Status Remark
1 FeedGasMeteringPackage VisualCheck Good
2 LeanGasMeteringPackage VisualCheck Good
3 FuelGasMeteringPackage VisualCheck Good OnprogressapprovalbyMigas
4 InletSlugCatcher VisualCheck Good
5 CondensateDegasserVessel VisualCheck Good
II.GASTURBINECOMPRESSORS&FACILITIES
No. Equipment RH Activities Status Remark
1 FeedGasSuctionScrubbersA/B/C VisualCheck Good
1.CheckalloperatingparameteronHMI(logsheet)
A=29121
2.Checkbeltandbearingnoiseoflubeoilcoolersand A=Running
2 FeedGasCompressorsA/B Good
fansuctionstrength B=Running
B=28500
3.Checkalarmsummary
3 FeedGasComp.Disch.CoolersA/B/C VisualCheck Good
4 FeedGasDisch.ScrubbersA/B/C VisualCheck Good
5 CommonSpareCompressorC C=21213 VisualCheck Good C=Standby
1.CheckalloperatingparameteronHMI(logsheet)
A=26674 A=Running
2.Checkbeltandbearingnoiseoflubeoilcoolersand
6 LeanGasCompressorsA/B Good B=Running
fansuctionstrength
B=27134
3.Checkalarmsummary
7 LeanGasComp.Disch.CoolersA/B VisualCheck Good

III.GASDEHYDRATIONUNIT
No. Equipment RH Activities Status Remark
1 DehydrationVesselsA/B/C VisualCheck Good
2 KVValve VisualCheck Good
3 DustFilter VisualCheck Good
1.PMVisualCheck&LogSheetParameter Monitoringincreasesealleakage
4 RegenerationGasCompressor Good
2.PMcheckalarmsummary from0.4psigto2.34psig
1.PMchecksettingpressurefuel
BNR=21982
2.PMcheckminmaxreadingflamescanner
5 RegenerationGasHeater Good
3.PMCheckalarmsummary
SYS=35810
4.PMcheckinstrumentairpurgingenclosure
1.VisualCheck
6 RegenGasCooler Good
2.WeeklycheckVibration
7 K.O.Drum VisualCheck Good

IV.CRYOGENICUNIT
No. Equipment RH Activities Status Remark
1 GasLiquidExchanger VisualCheck Good
2 FeedResiduExchanger VisualCheck Good
3 ColdSeparator VisualCheck Good
Undermonitoringafterresetting:
1.PMVisualCheck&LogSheetParameter
1.TimedelayOST3S
4 TurboExpanderPackage 32760 2.PMCheckalarmsummary
2.TimedelayHighVibTripComp
3.PMcheckinstrumentairpurgingenclosure
Side5S
5 ExpanderComp.DischargeCooler VisualCheck Good
6 DeEthanizerColumn&Reboiler VisualCheck Good
7 RefluxExchanger VisualCheck Good
A=19787 A=Standby
8 RefluxPumpsA/B VisualCheck Good
B=4069 B=Running
9 RefluxAccumulator VisualCheck Good
A=16936 A=Running
10 NGLPumpsA/B VisualCheck Good
B=15755 B=Standby
EXTRACTIONPLANTPT.PERTASAMTANGAS
MAINTENANCEREPORT
25January2017
V.UTILITIES
No. Equipment RH Activities Status Remark
A=19870 A=Standby
1 PotableWater VisualCheck Good
B=15572 B=Running
A=16509 A=Standby
2 UtilityWaterPump VisualCheck Good
B=18228 B=Running
A=2010 A=Standby
3 RawWaterPump VisualCheck Good
B=7654 B=Standby
A=7380 A=Lead
4 InstrumentAirCompressorA/B VisualCheck Good
B=8387 B=Lag
5 InstrumentAirReceiver&Header VisualCheck Good
6 MethanolInjectionPumpsA/B VisualCheck Good
7 HotOilMakeUpPump&ExpansionVessel 4,54 VisualCheck Good Standby
A=17099 A=Standby
8 HotOilCirculationPump&Filter VisualCheck Good
B=19525 B=Running
BRN=32470 1.PMchecksettingpressurefuel
Monitoringplugleakageafter
9 HotOilHeater 2.PMcheckminmaxreadingflamescanner Good
SYS=36871 groutingwithSIKA
3.PMcheckalarmsummary
10 HPFlarePackage VisualCheck Good
A=7.48
11 K.O.Drum&Pump VisualCheck Good
B=7.17
12 ColdVent VisualCheck Good
13 ClosedDrainDrum&Pump 188,52 VisualCheck Good Standby
14 ClosedDrainSumpPump 483,45 VisualCheck Good Standby
15 APISeparator&Pumps 181,67 VisualCheck Good Standby
16 WaterSumpPump 693,18 VisualCheck Good Standby
17 PigLauncher&PigReceiver VisualCheck Good
18 DieselFireWaterPump 79,00 VisualCheck Good Standby
19 JockeyPump 113,00 VisualCheck Good Standby
20 FuelGas&SealGas VisualCheck Good
A=14901 1.VisualCheck&LogSheetParameterGEGA&GEGB
A=Running
2.MonitorReadingTempCylinderHeadGEGA#9until
B=30235 B=Running
21 GEGA/B/CandDEG 1255degF&#11until1230degF Good
C=27219 C=Standby
(range11901292degFrefermanualbook)
D=Standby
D=385,1 3.MakeupubeoilGEGA&Beach20Ltr

VI.FACILITY&PIPELINE
No. Equipment Activities Remark
1 Pipeline MonitoringPressureNGL
Visualcheck,Rushremoval,RepaintingValves&LinetoFlareheader,Fuelgas
2 DHUSystemArea
metering,AirinstrumentareapiperackContinue
3 LineHotOilHeater Check&monitoringareaHotoilheateraftercementingplug(causeleaking)
InstallSlipBlindLineLVRegentGasKODrum,GroutinngLineHotOiland
4 CorrectiveMaintenance
Monitoring.
CheckRepairLevelTransmitter,ChangeSettingforURV&LRV,Calibrateand
5 FeedGTCA&GTCCommon Finished
Simulatetehetransmitterwithoilmedia

6 I/ACompressor01K5501A ActionFollowuptriphightemperaturedischarge2ndstage

1.Visualcheck
LinetoFlareheader,Fuelgasmetering&Air
7 2.Rushremoval
instrumentatPipeRack
3.RepaintingValves
8 DelugeSystem MonitorleakageaftertemporaryrepairseatvalveXV6022 Inprogressprocureseatvalve
VII.OTHERS
No. Equipment Activities Remark
1.PMchecktemperature
1 CCRArea 2.PMvisualcheck&logsheetparameterDCS&PLC
3.ReplacevbeltHVACcompressorB
1.PMchecktemperature
2.PMvisualcheck&logsheetparameterDCS&PLC
2 MCCArea&BatteryChargerRoom 3.VisualcheckandLogsheetLVSGR&MCC01SGR7102/MCC7101/
MCC7102andLVSGR&MCCEmergency01SGR7102/MCC7103,
01BC7101A/B,01UPS7101A/B/C
EXTRACTIONPLANTPT.PERTASAMTANGAS
MAINTENANCEREPORT
25January2017
VIII.MAINTENANCEISSUE/OUTSTANDINGITEM
No. Item Activities Remarks
1 LTZ1001HH(bypass)&LTZ1001LLspikevaluewhenlightning Addsurgearrestertoprotectfalsesignalduetolightning
2 FeedGasCompressorBconnectiontoDCSmodbad WaitingEthernetcard,POalreadysubmittotransavia
3 P6003 ChangeitemPRfromcrankmoduletopanelsystem
IX.SPAREPART/WAREHOUSE
No. Item Remarks
1 RepairmanualvalveGLT16"=2ea&GLT6"=2eaforbackupKVValve Alreadydelivertovendor
2 PrepareselenoidvalveforcontrolvalvewithbrandAscoforspareitem Logistic/Procurementprocess
3 Repair12unitCylinderHeadGEGforspareitem(estimationusedendofJanuary2017TOHB) SpeedupprocesstoTrakindo
4 PMGEGC(estimationfirstofJanuary2017),additionalworkformeasuregasemissionsbyTrakindo Procurementprocess
5 TOHGEGB(estimationendofJanuary2017),additionalworkformeasuregasemissionsbyTrakindo Procurementprocess
6 PrepareprocureEMCP+2forsparepanelGEG Procurementprocess
7 PreparecreatePRreplaceflexiblecable,valvemembrane&columnforAT3501 Procurementprocess
8 PrepareprocurenewHMISolarTurbineforspareitem Procurementprocess

Preparedby, Acknowledgedby,

Dandy AcepSaefuddin
(MaintenanceSuperintendent) (Operation&MaintenanceManager)

TrendingTurboExpander
15.660 15.621 15.393 15.463 15.664 15.722 15.530 15.345 15.616 15.607
15.112 15.059 15.209 15.196 15.436 15.433 15.426 15.426 15.336 15.452 15.379 15.432 15.387 15.372
2,40 16.000
2,20
14.000
2,00

Exp.SuctionPressure
1,80 1,79 12.000
1,63 1,72
1,59 1,74 1,61
1,60 1,57
1,60 1,55
1,56 1,50 1,60 1,49 10.000
1,45 1,54
Vibration

1,47 1,37
1,40 1,43 1,30 1,34 1,23 1,35

Speed
1,14 1,23 1,20 1,20
1,20 1,16
1,21 1,19 1,25 1,09 1,23 8.000
1,18 1,18
0,98 1,20 1,16 1,11
1,07
1,05 0,93 0,94 1,05 0,94 1,05 1,10
1,03 0,98 0,97 1,19 0,99 0,95 1,01
1,00 1,00 0,93 1,02 0,98 0,92 0,97
0,95 0,94 0,93 0,97 0,84
0,85 0,86 0,91 0,90 0,91 0,92 0,92 0,73 6.000
0,70 0,77 0,82
0,80 0,83 0,65 0,74
0,59 0,73
0,82 0,64 0,66 0,66 0,70
0,60 0,57 0,63 0,60 0,65 0,61 0,63 0,65 4.000
0,59 0,58
0,58 0,63
0,40
732 725 723 725 722 719 715 719 720 720 720 721 725 722 720 720 724 728 734 734 724 721 722 721 2.000
0,20

8:40 11:15 14:00 17:10 8:40 11:30 14:25 17:10 8:20 10:35 14:15 17:10 6:00 8:00 17:30 20:00 6:00 8:20 17:30 20:00 6:00 8:20 17:30 20:00
20Jan17 21Jan17 22Jan17 23Jan17 24Jan17 25Jan17
Time

ExpVib"X"(mils) ExpVib"Y"(mils) CompVib"X"(mils) CompVib"Y"(mils) Speed(Rpm) ExpSuctPress(Psi)

PipelinePressure
350
286 278
300 270 263 256 248 243 237 232 230
250
Pressure(Psi)

210
186,38
185,03 185,00
200
184,38 134,77
134,96 133
132 132,28
131,85 130,80 130
130,79 128
129 127,37
127,37 125 123
122 120,43
119,75
150 188,5 111,3
110,7
135,19 133 132,69 130,47 130 128 127,98 125 123 119,13 109,7
100 137,89 137 135,44 133,79 133 132 130,89 127 125 121,91 112,4
50
0
KP0 KP9 KP21 KP33 KP42 KP54 KP63 KP68 KP78 KP79 KP86 NGLSurge
Drum
Location
PresureDesign 21Jan17 23Jan17 24Jan17 25Jan17

You might also like