EXTRACTIONPLANTPT.

PERTASAMTANGAS
MAINTENANCEREPORT
14January2017
I.SKGX
No. Equipment RH Activities Status Remark
1.VisualCheck
2.ProblemFlowcomduetocommunicationtoDCSnot
1 FeedGasMeteringPackage connected Good Continue
USBtoserialconverteralreadyinstall
WaitingPEPtoresettingthecommmunication

1.VisualCheck
2.ProblemFlowcomduetocommunicationtoDCSnot
2 LeanGasMeteringPackage connected Good Continue
USBtoserialconverteralreadyinstall
WaitingPEPtoresettingthecommmunication

3 FuelGasMeteringPackage VisualCheck Good OnProgressapprovalbyMigas


4 InletSlugCatcher VisualCheck Good
5 CondensateDegasserVessel VisualCheck Good

II.GASTURBINECOMPRESSORS&FACILITIES
No. Equipment RH Activities Status Remark
1 FeedGasSuctionScrubbersA/B/C VisualCheck Good
A=28857 1.CheckalloperatingparameteronHMI(logsheet)
2.Checkbeltandbearingnoiseoflubeoilcoolersand A=Running
2 GasTurbineCompressorFeedA/B Good
fansuctionstrength B=Running
B=28236
3.Checkalarmsummary
3 FeedGasComp.Disch.CoolersA/B/C VisualCheck Good
4 FeedGasDisch.ScrubbersA/B/C VisualCheck Good
5 GasTurbineCompressorCommonC C=21189 SwithGTCCommonCtoLeanA Good C=Standby
1.CheckalloperatingparameteronHMI(logsheet)
A=26434 A=Running
2.Checkbeltandbearingnoiseoflubeoilcoolersand
6 GasTurbineCompressorLeanA/B Good B=Running
fansuctionstrength
PrepareprocurenewHMI
B=26870 3.Checkalarmsummary
7 LeanGasComp.Disch.CoolersA/B VisualCheck Good
III.GASDEHYDRATIONUNIT
No. Equipment RH Activities Status Remark
1 DehydrationVesselsA/B/C VisualCheck Good
2 KVValve VisualCheck Good
3 DustFilter VisualCheck Good
1.PMVisualCheck&LogSheetParameter Monitoringincreasesealleakage
4 RegenerationGasCompressor Good
2.PMcheckalarmsummary from0.4psigto1.5psig
1.PMchecksettingpressurefuel
BNR=21718
2.PMcheckminmaxreadingflamescanner
5 RegenerationGasHeater Good
3.PMCheckalarmsummary
SYS=35546
4.PMcheckinstrumentairpurgingenclosure
6 RegenGasCooler VisualCheck Good
7 K.O.Drum VisualCheck Good
IV.CRYOGENICUNIT
No. Equipment RH Activities Status Remark
1 GasLiquidExchanger VisualCheck Good
2 FeedResiduExchanger VisualCheck Good
3 ColdSeparator VisualCheck Good
1.PMVisualCheck&LogSheetParameter
2.PMCheckalarmsummary
4 TurboExpanderPackage AlreadyStarted
3.PMcheckinstrumentairpurgingenclosure4.
ExpanerTripduetohighvibration
5 ExpanderComp.DischargeCooler VisualCheck Good
6 DeEthanizerColumn&Reboiler VisualCheck Good
7 RefluxExchanger VisualCheck Good
1.VisualCheck
A=19739
2.PMPumpB A=Running
8 RefluxPumpsA/B Good
Cleaningpump&accessories B=Standby
B=3829
Replacethrustbearingoil
9 RefluxAccumulator VisualCheck Good
A=16696 A=Running
10 NGLPumpsA/B VisualCheck Good
B=15707 B=Standby
EXTRACTIONPLANTPT.PERTASAMTANGAS
MAINTENANCEREPORT
14January2017
V.UTILITIES
No. Equipment RH Activities Status Remark
A=19870 A=Standby
1 PotableWater VisualCheck Good
B=15308 B=Running
B=16485 A=Standby
2 UtilityWaterPump VisualCheck Good
B=17964 B=Running
A=2010 A=Standby
3 RawWaterPump VisualCheck Good
B=7654 B=Standby
A=7324 A=Lead
4 InstrumentAirCompressorA/B VisualCheck Good
B=8308 B=Lag
5 InstrumentAirReceiver&Header VisualCheck Good
6 MethanolInjectionPumpsA/B VisualCheck Good
7 HotOilMakeUpPump&ExpansionVessel 4,54 VisualCheck Good Standby
A=17075 A=Standby
8 HotOilCirculationPump&Filter VisualCheck Good
B=19261 B=Running
BRN=32206 1.PMchecksettingpressurefuel
9 HotOilHeater 2.PMcheckminmaxreadingflamescanner Good
SYS=36607 3.PMcheckalarmsummary
10 HPFlarePackage VisualCheck Good
A=7.48
11 K.O.Drum&Pump VisualCheck Good
B=7.17
12 ColdVent VisualCheck Good
13 ClosedDrainDrum&Pump 188,52 VisualCheck Good Standby
14 ClosedDrainSumpPump 483,45 VisualCheck Good Standby
15 APISeparator&Pumps 181,67 VisualCheck Good Standby
16 WaterSumpPump 693,18 VisualCheck Good Standby
17 PigLauncher&PigReceiver VisualCheck Good
18 DieselFireWaterPump 79,00 VisualCheck Good Standby
19 JockeyPump 113,00 VisualCheck Good Standby
20 FuelGas&SealGas VisualCheck Good
A=14638
1.VisualCheck&LogSheetParameterGEGA&GEGB A=Running
B=29971 2.MonitorTempCylinderHeadGEGA#9=1255degF& B=Running
21 GEGA/B/CandDEG Good
C=27219 #11=1230degFverifiedwithIRTempGun C=Standby
(range11901292degFrefermanualbook) D=Standby
D=385,1

VI.FACILITY&PIPELINE
No. Equipment Activities Remark
1 Pipeline MonitoringNGLPressurePipeline,MonitoringKp.79&86 Continue

2 ColdInsulationCryogenicArea Cleanning Continue

3 HandrillareaClosedDrain Chippingfoundation Continue


4 StairCloseDrainDrum Repainting Continue
LineOpenDrainExpander&StrainnerGasLiquid
6 Cleanning Finish
ExchangerPassC
7 DelugeSystem MonitorleakageaftertemporaryrepairseatvalveXV6022 Inprogressprocureseatvalve
Replaceharddiskusingexistingbackupserverandrestoreconfigurationtolatest
8 PLDSServer Preparetoprocureharddisk
programduetocan'tbooting
WaitingConverterSerialtoUSB,
9 FlowComp CheckComunicationflowcompSKGXtoDCSduetoStuck
AlreadyLocalPurchase
ClosedMonitoringtemperaturecylinderheadofGEGA,Speciallynumber09,the
10 GEGA
highesttemperature1243"F
11 TurboExpander Changedelaytimetripcompressorsidevibrationfrom3000msto5000ms Statuscompleted

12 PortableWaterPump PMService Statuscompleted


EXTRACTIONPLANTPT.PERTASAMTANGAS
MAINTENANCEREPORT
14January2017
VII.OTHERS
No. Equipment Activities Remark
1.PMchecktemperature
1 CCRArea 2.PMvisualcheck&logsheetparameterDCS&PLC
3.Cleaning&ReplaceBeltIntakefanHVACIF2
1.PMchecktemperature
2.PMvisualcheck&logsheetparameterDCS&PLC
2 MCCArea&BatteryChargerRoom 3.VisualcheckandLogsheetLVSGR&MCC01SGR7102/MCC7101/
MCC7102andLVSGR&MCCEmergency01SGR7102/MCC7103,
01BC7101A/B,01UPS7101A/B/C
PMGasDetector
1.Checkerrorcodeforsensor
3 AE7701/7702 2.Makesureindicationwas"0"
3.Checkconnectioncable
4.Cleaningsensorandhousing
VIII.MAINTENANCEISSUE/OUTSTANDINGITEM
No. Item Activities Remarks
1 LTZ1001HH(bypass)&LTZ1001LLspikevaluewhenlightning Addsurgearrestertoprotectfalsesignalduetolightning
2 FeedGasCompressorBconnectiontoDCSmodbad WaitingEthernetcard,POalreadysubmittotransavia
3 P6003 ChangeitemPRfromcrankmoduletopanelsystem

IX.SPAREPART/WAREHOUSE
No. Item Remarks
1 RepairmanualvalveGLT16"=2ea&GLT6"=2eaforbackupKVValve Alreadydelivertovendor
2 PrepareselenoidvalveforcontrolvalvewithbrandAscoforspareitem Logistic/Procurementprocess
3 Repair12unitCylinderHeadGEGforspareitem(estimationusedendofJanuary2017TOHB) SpeedupprocesstoTrakindo
4 PMGEGC(estimationfirstofJanuary2017),additionalworkformeasuregasemissionsbyTrakindo Procurementprocess
5 TOHGEGB(estimationendofJanuary2017),additionalworkformeasuregasemissionsbyTrakindo Procurementprocess
6 PrepareprocureEMCP+2forsparepanelGEG Procurementprocess
7 PreparecreatePRreplaceflexiblecable,valvemembrane&columnforAT3501 CreatePR

Preparedby, Acknowledgedby,

Dandy AcepSaefuddin
(MaintenanceSuperintendent) (Operation&MaintenanceManager)
EXTRACTIONPLANTPT.PERTASAMTANGAS
MAINTENANCEREPORT
14January2017

TrendingTurboExpander
15744,0015543,0015500,00 15781,0015680,0015689,0015724,0015781,0015680,0015689,0015568,0015683,00
15446,0015706,0015671,0015567,0015573,0015724,00 15489,0015546,0015473,0015583,00 15398,0015379,0015281,0015250,0015318,00
2,20 15067,00 16000,00

2,00
14000,00
1,80 1,67 1,76
1,65
1,65 1,73 1,62
1,64 1,70 1,53 12000,00
1,60 1,64

Exp.SuctionPressure
1,39 1,42 1,45 1,49
1,40 1,40
1,39 1,38
1,42 1,40 1,42 1,35
1,40 1,47 1,40 1,35
1,40
1,32 1,36
1,42 10000,00
1,31 1,36 1,32 1,40 1,30 1,23 1,19
Vibration

1,15 1,16 1,24 1,17


1,18
1,17 1,17 1,18 1,25 1,11

Speed
1,20 1,15 1,15 1,16 1,15 1,15 1,24
0,95 0,98
0,96 8000,00
1,06 1,08 0,89
1,00 0,86 0,87 0,88 0,86 0,87 0,88 0,85 0,86
0,98
0,79 0,83 0,83 0,81 0,80 0,82 0,80 0,80 0,80
0,76 0,75 0,86 0,87 0,86 0,87 0,90 0,77 0,76
0,73 0,89 0,83 0,82 0,83 0,82 0,84 6000,00
0,80 0,78 0,81 0,81 0,80 0,80 0,80 0,78
0,75 0,75 0,77 0,79 0,77 0,75 0,77
0,60 0,72 0,58 0,71
0,60 0,61
4000,00
0,38
0,40
2000,00
0,20 723,00 725,00 730,00 723,00 724,00 723,00 724,00 726,00 723,00 718,00 725,00 724,00 723,00 718,00 725,00 724,00 725,00 728,00 723,00 728,00 726,00 724,00 724,00 723,00 726,00 727,00 726,00 725,00

0,00 0,00
17:00:00

20:00:00

17:00:00

20:00:00

11:20:00

14:20:00

18:10:00

11:20:00

14:20:00

18:10:00

10:13:00

14:01:00

16:18:00

10:13:00

14:01:00

16:18:00

10:13:00

14:01:00

16:18:00
6:00:00

8:00:00

6:00:00

8:00:00

8:51:00

8:51:00

8:43:00

8:43:00

8:43:00
08/01/2017 09/01/2017 10/01/2017 11/01/2017 12/01/2017 13/01/2017 14/01/2017
ExpVib"X"(mils) ExpVib"Y"(mils) CompVib"X"(mils)
Time CompVib"Y"(mils) Speed(Rpm) ExpSuctPress(Psi)

PipelinePressure
350,00

300,00 286,00
278,00
270,00
263,00
256,00
248,00
243,00
250,00 237,00 232,00 230,00
210,00

188,92
189,71
Pressure(Psi)

200,00 185,63 185,00


188,07

140,78
137,42 138,00 136,92
150,00
189,47 134,05 135,00
133,00 134,40
131,29 134,07
131,60
129,16 132,00
133,00 132,00
130,00 129,37
130,11
128,00 127,00 126,31 127,00
125,00 125,00
123,00
137,69 135,00 133,62 122,00 120,00 120,04
119,45
116,29
130,84 128,00 127,00 126,31 123,00 122,00 110,20
109,00
107,00
115,17
135,00 106,40
100,00 137,88 132,00 130,00
134,59 131,79 125,00 123,00
128,38
118,43 108,00

50,00

0,00
KP0 KP9 KP21 KP33 KP42 KP54 KP63 KP68 KP78 KP79 KP86 NGLSurge
Drum
Location
PresureDesign 10Jan17 11Jan17 12Jan17 13Jan17 14Jan17