COMPANY PROFILE
Digicont, a 2 decade old company manufacturing Electronic Instruments for Process Industries, has generated lot of goodwill
for quality, timely deliveries at low cost. Companys name is specially remembered for its well accepted product - Alarm Annunciator. The
fact - that repeat orders are received from clients in India and abroad - in itself is an evidence of products quality and good services.
Regular Indian customers include EIL, ONGC, IPCL, BHEL, SAIL, FCI, IOC, NTPC, CCI, ILK, Siemens, Alstom, Grasim, Indian
Rayons, all State Electricity Boards. Products are being exported to Kuwait, Qatar, Malaysia, Philippines, Dubai, Thailand, Mauritius,
Vietnam & Korea, etc.

PRODUCTS
u ALARM ANNUNCIATOR
With Terrificfeatures like - LED type windows, any voltage AC/DC working, easy NO/NC input changeability. Accessories such
as Electronic Hooter & Push Button station available.
m Series - 1800. Annunciation system. Microcontroller based 4-channel plug-in card type system for easy maintenance.
Available in integral as well as remote version in various enclosure types. With 8 selectable Alarm Operating sequences.
Automatic sound cancellation.
m Model - 1604/06/08/12. Low cost 4 / 6 / 8 / 12 window integral flush panel mounting Annunciators with built in push button.
No plug-in cards. Mocrocontroller based technology. 8-selectable Alarm sequences. Auxilliary tripping contact. Automatic
sound cancellation.

u ELECTRONIC TIMER
Available in 4 timing modes, ON-Delay, OFF-Delay, Monoshot & Free running.
m Series-2400 : Plug-in base mounting / Flush panel mounting versions available
m Series-2000D : Din Rail mounting
m Series -2000 : Wall / surface mounting.

u DIGITAL TEMP. SCANNER 3116-M


with RTD / ThC inputs. Upto 16 channels, Auto LRC, Auto CJC, Auto Linearisation. Auto/Manual scanning. Open channel
indication. Set points, 2 maxm., for each channel. Scanning speed etc. programmable. Max. 8 relay contacts for Alarm/Trip
signalling/controls. Compact size 144 x 144.

u DIGITAL INDICATOR
Microcontrollser based. Soft touch keys for programming. EEprom memory for programmed data retention under no power. Bright
7 segment LED displays.
m Model DTC213 / 234 / 4121 : Digital Temp. Indicating controllers with selectable input sensor type. 90-270 V AC opera
tion. Upto 2 set-points & alarm relays. Various DIN sizes.
m Model LI-4113 / DPC4131 : 4-20 mA / 0-20 mA / 1-5 V dc input Digital Indicating Cintrollers with programmable range.
24V DC supply output available for powering the current loop transmitter. Upto 2 set-point & alarm relays. Various DIN sizes.

u MULTICHANNEL TEMP. INDICATOR


Upto 8 channel temp. indication. Displays channel no. & its temperature reading one-by-one. Auto or Manual channel selection
facility. Selectable input sensor type. 2 set-point & alarm relays with common setpoints for all channels. Channel Hold facility
for alarm channel.

u DC REGULATED POWER SUPPLY


Fixed voltage models available in various current capacities ( 0.5A / 1A / 2A /5A ) with analog load current meter. Output S/C &
O/L protection. Load & line regulation - 0.1%

u AND OTHER ITEMS such as :


m DIGITAL MAINS FREQUENCY INDICATOR
m DIGITAL PRESET COUNTER
m DIGITAL TIMER & TIME TOTALISER
m PROGRAMMED SEQUENCE TIMER
m ALARM RELAY
m DIGITAL CLOCK
Alarm Annunciation System
Digilarm Series - 1800

FEATURES
Latest Technology, Microcontroller based.
Masterless 4-channel Plugin cards.
LED windows with computer composed legends
on photofilm.
Works on any volts AC or DC. Plug-in type SMPS
module.
Jumper selectable alarm sequences, separately for
every card.
NO/NC input selectable by DIP switches on every
card
First - out group expansion
Auxillary tripping contact
Automatic sound cancellation

General Masterless Modules


By adopting modular design combined with latest In safety critical applications like Alarm Annunciators, it
Microcontroller technology, Digilarm Series 1800 is paramount that the reliablity of equipment is second
provides more features than any other system available. to none. Unlike other microprocessor based systems,
High noise immunity is provided at very low power, hence the Series - 1800 Annunciator has no master module
ideally suited for all industrial environments. and hence no single source of system failure. Each 4 -
way alarm card has its own Microcontroller which is
4-Annunciation channels are mounted on one card capable of complete function including flasher
module for compactness and cost reduction. generation. If this board is removed or the IC goes faulty,
then no other cards working is affacted. The worst
For input derived from dry field contacts, the system is
system fault that could occur would be loss of 4 - Alarm
supplied either in Integral on Split architecture. The visual
ways. And it can be set right just by replacing with a
displays are available in any Rows x Column
spare card.
configuration of 8 or more windows. The integral unit
and the windows cabinet in case of Split system are flush Field Programmability
panel mounting type.
System uses a Plug-in, SMPS type, Power supply
Audible alarm device (Hooter/buzzer etc.) and Push
module having Universal input (any volts between 90-
Buttons are generally supplied loose for separate
270V AC or DC). System working voltage alteration is
mounting but can be provided on front of the Annunciation
therefore easily possible without making any change in
unit itself, if so required by the customer.
the supply unit.
Unsurpassed versatility of the Series - 1800 system
Alarm operational sequence, one out of 8 given in the
permits field alteration of virtually every major aspect of
sequence chart can be selected by shorting / opening
Annunciators operation - Working voltage, NO/NC input
of 3-jumpers provided on each card. This will assign
Alarm Sequence, First-out groups, etc.
alarm sequence for the 4-Ann. channels on that very
Use of microcontroller has greatly reduced the number card. Desired sequence must be individualy assigned
of components, thereby enhancing reliability. No to every card in an Ann. unit.
maintenance required. Not even lamps. Long life, super
Operation from NO or NC input contact can be changed
bright LEDs have been used. No parts that could call
on a per point basis simply by flip of DIP switches
for replacements.
provided on every card.
TECHNICAL DATA Sequence Logic Cards
Power Supply Any volts between 90-270V AC or DC The Alarm logic module uses Solid State Microcontroller
earthed or floating technology to provide unparalled reliability. Glass epoxy
Power Consumption 1.5 Watts per channel. PC boards are used. 4 - idendical annunciation ways
are packaged on each card moudle which plug into
(i) Potential free contact NO or NC connector sockets of the mother board and are
type. Individually selectable for each interchangeable. 4 Red LED indicators working in
channel by DIP switch on the logic parallel to the LED lamps output is a standard feature.
card. One Yellow LED indicator is provided to show
(ii) Optionally available Transistor or healthiness of the mocrocontroller IC and it flashes when
logic level input from PLC or any other everything is healthy.
device. Single 24 V DC Power is needed and voltages for
Line Resistance Resistance of field cable can be upto working of logic, lamps etc. are generated on the card
1.0 K Ohm itself. Conscientiously designed circuit schemes are
Interrogation voltage 24V D.C. used to filter out EM & RF noises associated with the
field inputs, Push Buttons and Power Supply.
Response Time 50 m Sec. (Max.)
First - out Resolution 50 m Sec. (Max.)
LED windows
The visual display window requires only 30 mA to
SWC at Inputs 2.5 KV as per IEEE, 472, 1974
operate in comparison to 120 mA for conventional
Flashing Frequency Fast Flash - 270 c/s per Min. filament lamps and do not require replacements. LEDs
Normal/Slow flash - 54 c/s per Min. can be ordered in two different colours. RED/YELLOW
Output Contacts 2NO Contacts, One for hooter driving. to easily differentiate groups of points by urgency, First
Other as Tripping contact. - out groups or nature of alarms.
Contact Rating 250 V AC, 3A (Resistive) Push Buttons
Ambient Temp. Upto 55 0C Terminals are provided to connect 4 PBs for Test (Full
Relative Humidity Upto 95% sequence test), Lamp Test, Accept and Reset functions.
In case of First - out sequence test facility is irrelevant
Windows (i) 4 - sizes are availavle. Customer
and therefore has not been provided. The Test button
may give his choice looking into
works as First out Reset Button. In case of Integral
available panel space.
Annunciators the push buttons, as an option, can be
Window Legends Letter provided on the front of the Annunciation Unit itself
size Lines Letters size
First-out Group Expansion
70 50 4 16 4 mm
In case of First -out sequences the first fault in a group
75 42 4 18 4 mm
of faults has to be notified. In some applications the group
70 40 4 16 4 mm
can be very large. Series-1800 can be used in multi-
55 30 4 16 3 mm
units. First-out group expander output has been made
(ii) All windows are ABS plastic
available on each unit. FOEXP of the different units
moulded. The window facia is slanted
can be looped together to make a bigger first-out group.
7.5 0 off vertical so that display faces
into the viewing area. Facia is slide- Automatic Sound Cancellation
in type from top of the window so that Whenever any new fault occurs, the alarm hooter contact
legend plate can be replaced easily. HTR closes. It breaks when ACK button is pressed or
Color of window light Either Red or Yellow (Choice to be after 10 Mins. automatically.
given while ordering) Split Architecture
The windows and the Logics can be supplied in seperate
enclosures to be mounted seperately.
Windows are arranged in any rows x column
configuration in flush panel mounting window-boxes with
rear connection terminals. Logics together with power
6-F, Industrial Estate, Tel : 91-744-450568, 364612
KOTA - 324007, INDIA Fax : 91-744-450568, 430587 supply modules and the input/output terminals are
supplied in wall mounting chasses (if the system is small)
e-mail : digicont@kappa.net.in or in standard Cabinets for large systems.
Alarm Annunciator
General Purpose, Integral MODEL : 1604/1606/1608/1612

FEATURES
Latest Technology
Microcontroller based
LED Windows
Works on any volts AC or DC
DIP switch selectable Alarm
Sequences
NO/NC input selectable by DIP
switches
Low cost
Small in size & weight

STANDARD FACILITIES INCLUDE


Alarm Hooter driving contact
Ring back Hooter driving Contact
Auxillary/Tripping Contact
First-out group expansion
Flasher Synchronisation
Automatic Sound Cancellation
Built-in Push buttons with facility
to connect Remote also.

16XX represents more than a premier use of CMOS microcontroller has been used, whose quality is well known.
Microcontroller based Logic in a general Number of components used have been greatly reduced, thereby
purpose Annuciator. It has some uncanny enhancing realibility. Small size allows application to users not
versatillity. Virtually every major aspect of the having large panel space. High noise immunity, robust cabinet,
quality plated terminals make the instrument suitable for use in
annunciators operation can be altered in the
Power plants, Chemical Plants, Small D.G. sets etc. Outstanding
field with nothing more than the flip of a dip
features are
switch. (i) Operates on any volts AC or DC
16XX is functional & cost efficient for the routine (ii) Selectable sequences.
monitoring of a few points as it is for Mount it, connect it & forget it. No maintenance required. Not
sophisticated multi-sequence applications. even Lamps. Longlife superbright LEDs have been used. No
components, no parts, that could call for replacements.
TECHNICAL DATA FILED PROGRAMMABILITY
Power Supply Any volts between 90-270 V AC Alarm operational sequence can be selected or changed
or DC, earthed or floating simply by change of DIP switches. Operation from NO
Power Consumption 1604 - 15VA or NC input contact can be changed on a per point basis
1606 - 20VA again simply by change of DIP switches. One DIP switch
1608 - 20VA marked RB/X has been provided to programme a
1612 - 25 VA common relay contact marked RBHTR / XRL. It selects
Alarm Inputs (i) Potential Free contact NO or either Ringback Hooter contact or Auxillary/Tripping
NC type (Selectable by dip switch contact in case of Ringback sequences. In case of other
available at the rear. Seperate sequence (without Ringback) this switch is inoperative
switch available for every input) and the output contact in Aux. /Tripping contact only.
(ii) Optionaly available Transistor LED WINDOWS
or Logic level input from This visual display window requires 20 mA to operate
Programmable Logic Controllers versus 120 mA for conventional filament lamps and do
(PLC) or any other device not require replacements. LEDs can be ordered in two
Line Resistance Resistance of field cable can be different colours, Red/Yellow to easily differentiate
upto 1.0 K-om. groups of points by urgency, First-out grouping or nature
Input Interrogation Voltage 24 DC of alarms.
Responce Time 50 m-sec. (max.) PUSH BUTTONS
First Out Resolution Time 50 m-sec. (max.) 4- Push buttons have been provided on every unit for
SWC at Inputs 2.5 KV as per IEEE : 472, 1974 Test (Full sequence test). Lamp test, Acknowledge and
Reset functions. In case of First-out sequences a
Flashing frequency Fast Flash - 270 c/s per Min. Slow
sequence test facility is irrelevant and therefore has not
Flash - 54 c/s per Min.
been provided. The Test button works as First-out Reset
Output Contacts 2 NO contacts. One for hooter button. These 4- PBs connections have been brought
driving. Other selectable as out to the rear terminals also for remote PBs connections
Ringback Hooter/Auxiliary or for common PBs in case of multi-unit system.
contact.
FLASHER SYNCHRONISATION
Contacts Rating 250V AC, 3A, (resistive)
Windows Legend 45 30 mm.Can accomodate Every 16XX unit has its own flasher built inside. In case
of multi-unit system the flashing of each unit may be
writing area 4-lines different and therefore visualy does not look appealing.
Characters/line 12 of 4mm letters or 16 of 3mm A flasher synchronisation facility has therefore been
letters made available. Any unit can be considered as master
Colour of window light Either Red or Yellow (Choice to and the flasher output from master unit may be connected
be given while ordering) to the Flasher Synch. Inputs of all other units.
Ambient temp. Upto 55 deg. C FIRST-OUT GROUP EXPANSION
Relative humidity Upto 95% In case of First-out sequences the first faults has to be
Mounting Flush Panel notified. In some applications the group can be very large.
Model Over all size Cut-out size 16XX can be used in multi-units. First-out group expander
output has been made available on each unit. FOEXP
1604 96 96 mm 92 92 mm of the different units can be looped together to make a
1606 192 96 mm 186 92 mm bigger first-out group.
1608 192 96 mm 186 92 mm AUTOMATIC SOUND CANCELLATION
1612 192 126 mm 186 120 mm Whenever any new fault occurs, the alarm hooter contact
HTR closes. It breaks when ACK button is pressed or
after 10 min. automatically. In case of Ringback
sequences whenever any existing fault returns back to
6-F, Industrial Estate, Tel : 91-744-450568, 364612 normal the Ringback hooter contact RBHTR close. It
KOTA - 324007, INDIA Fax : 91-744-450568, 430587 breaks when RST button is pressed or after 10-mins
e-mail : digicont@kappa.net.in automatically.
Digital Temperature Indicator
Models : DTC213 / DTC234 / DTC4121

Features
4 Microcontroller based
4 Bright red 0.6 LED display
4 Programmable Input
4 Auto Linearisation / Auto LRC / Auto CJC
4 Alarm / Trip relay outputs
4 Supply 90-270V AC
4 Program retention through EEprom

Digicont offers a vide range of Digital Temperature Indicators for process


industries. Equipped with field selectable input sensor type, the alarms setting
is Digital. Thus, unlike other controllers which have Potentiometer / Thumb wheel
new setting, it gives high control accuracy. Set data is retained using EEprom instead
of battery . Line Resistance Compensation (LRC) in case of RTD input and Cold
Junction Compensation (CJC) in case of Thermocouple inputs is in-built &
automatic.
These instruments are available in various DIN sizes and can therefore
easily replace existing old technology instruments.
new
Specifications DTC213 DTC234 DTC4121
Type Microcontroller based Microcontroller based Microcontroller based
Display 3 digit, 0.6, Red, LED 4 digit, 0.6, Red, LED 5 digit, 0.6, Red, LED
Selectable Input & Range
RTD Pt100, 3 wire - 99 to 600 oC - 99.9 to 600.0 oC - 99.9 to 400.0 oC
K - type t/c - 99 to 999 oC - 100 to 1200 oC - 100 to 1200 oC
J - type t/c - 99 to 600 oC - 100 to 600 oC - 100 to 600 oC
Linearisation Software Software Software
Accuracy +0.25% F.S +1 count +0.25% F.S +1 count +0.25% F.S +1 count
Alarm O/P Single Dual Dual
Indication 1 LED lamp on front 2 LED lamps on front 2 LED lamps on front
Contacts 1 C/o, 5.0 Amp, 230V AC 2 C/o, 5.0 Amp, 230V AC 2 C/o, 2.0 Amp, 230V AC
Hysteresis Programmable Programmable Programmable
Hi / Lo type Programmable Programmable Programmable
Setting / Programing by front Keypad by front Keypad by front Keypad
Sensor Break 1xx indicated, relay off 1xxx indicated, relay off OPEn indicated, relay off
Power supply 90 - 270 VAC, 50 Hz 90 - 270 VAC, 50 Hz 90 - 270 VAC, 50 Hz
Ambient 0 to 50 oC 0 to 50 oC 0 to 50 oC
Humidity Upto 95% Rh NC Upto 95% Rh NC Upto 95% Rh NC
Case ABS plastic molded ABS plastic molded ABS plastic molded
Bezel 48(W) x 48(H) x 100(D) 96(W) x 96(H) x 110(D) 96(W) x 48(H) x 120(D)
Panel Cut-out 45(W) x 45(H) 92(W) x 92(H) 92(W) x 45(H)

Tel : 917442450568 / 2364612


Fax : 917442450568
e-mail : digicont@kappa.net.in 6-F, Industrial Estate,
Website : www.digicont.co.in KOTA - 324 007 (INDIA)
Digital Multichannel Temp. Indicator
MODEL : LI - 4108 M

INTRODUCTION
Digital Multichannel Temp. Indicator Model LI-4108M is based
on CMOS Microcontroller to achieve high reliability. This indicator
has Universal Input. It accepts signal from Temp. sensor such
as RTD/ Thermocouple and can be configured accordingly by
programming the instrument. The Alarms level setting is also
Digital, unlike other controllers which have Potentiometer/Thumb
wheell setting, thus giving high control accuracy. Set data is
retained using EEprom instead of battery back up.
This low cost multichannel indicator performs almost like 8-
channel Temp. Scanner. Available in standard DIN size,
therefore, can easily replace existing old technology instruments.

DESCRIPTION
The Temp. Indicator has two display fields. Data field in 3 digit &
F E AT U R E S
Mode field in 2 digits. All digits are of 0.6" 7-segment Red LED
displays. In normal mode, Data field shall display temp. value and
4 Selectable inputs Pt100 / Tc-K / J / T
Mode field shall show Auto or Manuall mode and scanned channel
(same type for all channels ) no. There are 4 push Buttons on the front of the instrument panel
4 Avoids mechanical selector switches namely MOD, INC, SHR & ENT.
4 Auto Linearisation MOD Button
4 Auto LRC Upon power on, the system always enters in Auto mode and
shall select channel-1. This is indicated by A1 at the mode
4 Auto CJC
display field. The data field shows ch. 1 temp. value. The
4 Optional dual Set point & Alarm Relays, channel no. will be incremented automatically at the earlier
common to all channels with channel programmed Scan Rate.
Hold facility Press MOD button and the system shall enter into manuall mode.
4 Program retention by EEprom Mode field shall show 'M1'. Data field shall display temp. value
for ch.1, but, now the channel no. can be incremented manually
by pressing the INC button.

S P E C I F I C AT I O N Press MOD button again and system returns back to Auto


scanning mode.
Input : RTD Pt-100, Th/C - K, T, J
No. Of Channels : 8 (Max.) If MOD button is kept pressed for more than 10 seconds, the
Display : 0.6" Red, 7-segment LED displays system jumps to Set modes, explained separately.
Temp. Reading - 3 digit
Scan mode & Ch.No.- 2 digit INC Button
If the instrument is working in manual mode , by pressing this
Accuracy : +/- 0.5% +/- 1 digit
P.B., we can increment the selected channel no.
Alarm contacts : Two ; common for all channels
Setting : By front push button keys If the instrument lies in set modes, then, through this P.B. we
Relay Contacts : 2A at 250 V AC, resistive, can increase the value of a digit where cursor lies.
Relay Status indicated by Yellow &
Red LED lamps
SHR Button
If the instrument lies in set modes, then, through this P.B. we
Memory : EEprom
can shift the cursor right in the data field.
Supply voltage : 110/230 V AC
Ambient Condn. : 0 - 50 Deg. Cent. ENT Button
Upto 95% Rh. In case of set modes, after the set value/program is set by
using INC & SHR P.B's, ENT button is pressed and whatever
Size : 192 x 96 mm
data is available in the data field, it is saved in the memory.
Mounting : Flush Panel It is retained even when there is no power because of
Cut-out reqd.- 186 x 92 mm EEprom.
Input Sensor Sensor Code Range Resolution Accuracy Compensation
RTD, Pt-100, 2 wire 0 -25.0 to 199.9 0.10 C +/- 0.25% +/- 1digit Programmable LRC*
200 to 600 10 C
RTD, Pt-100, 3 wire 1 -25.0 to 199.9 0.10 C +/- 0.25% +/- 1digit Automatic LRC*
200 to 600 10 C
Th/C type K, Cr-Al 4 0 to 1200 10 C +/- 0.5% +/- 1digit Automatic CJC**
Th/C type J, Fe-Co 5 0 to 600 10 C +/- 0.5% +/- 1digit Automatic CJC**
Th/C type T, Cu-Co 6 0 to 600 10 C +/- 0.5% +/- 1digit Automatic CJC**

At the rear of the instrument, 2 rows of terminals have Push SHR button, the second digit from left shall start
been provided for connecting power supply, sensor and flashing. Set it 0/1/4/5/6 by pressing INC push button.
relay out-put contacts. These are codes of Input sensors to be used.
The status of the relays are indicated on the front by 2
LED lamps marked RL1 & RL2. A fixed level of The last two digits of the data field are for Scan Rate in
Hysteresis has been provided for the set points S1 & S2. seconds. Press SHR button so that one of the last 2
Provision has been made for automatic Line Resistance digits starts flashing. By use of INC push button set the
Compensation (LRC) in case of RTD and Cold Junction digit value as per desired scan rate. Press ENT push
Compensation (CJC) in case of thermocouples. button. Press MOD button to come out of the 'P' mode and
to put the instrument into its normal Temp. reading mode.
For nonlinear characteristics of the sensors, automatic
Linearisation has been provided through software.
CALIBRATION PROCEDURE
PROGRAMMING THE SET POINTS S1 / S2 Connect standard resistance box in 3-wire connection.
Keep MOD Button pressed for more than 10 secs. The Take value 138.5 ohm. Program the instrument in code 2
mode field shall show 'S1' and data field shall display the as described above and adjust Zero with the help of Zero
value of Set point no.1. To change this value press SHR adjust pot. Now, program the instruement in code 1 and
push button till the most significant digit starts flashing. adjust 100 with the help of Span adjust pot. The
Now change this digit value by pressing INC button till the instrument is now calibrated for all types of sensors.
desired value is displayed. Press SHR button again and Disconnect the calibrating resistance box and
the next digit shall start flashing. By use of INC push reprogramme the input sensor type as per your
button set the next digit value also. Repeat the process till requirement.
all the digits are set for desired value of S1. Now press
ENT push button and the set point S1 is programmed. SENSOR BREAK INDICATION
Press MOD button again, Mode field shall show 'S2' and Whenever input sensor for any channel gets open or is
data field shall display the value of S2. Programme S2 as unconnected then instrument shows Open on the data
explained above. field. Both the alarm relays remain de-energised in this
Now, press MOD button twice, Mode field shall show 'A1' condition
and data field shall start displaying the measured
Temperature reading. CHANNEL SKIP FACILITY
PROGRAMMING THE INSTRUMENT Though, instrument is for 8 channels, however, it can be
FOR CHANNEL HOLD / NO HOLD FACILITY, used for any number of channels lower than 8. The
SENSOR TYPE & SCAN RATE unused channel gets skipped automatically within 0.5
Sec. In Manual mode, however, channel will not skip but
shall show Open.
Keep MOD Button pressed for more than 10 secs. Mode
Field shall show 'S1' .Press MOD button twice further.
Mode Field shall now show 'P' denoting that instrument is OTHER MODELS AVAILABLE
in programming mode. In data field the most significant
LI- 4104 : 4 Channel indicator, in size 9696 mm
digit (first from left) shall start flashing. When it is set as
without any set point & alarm relay
'1', channel hold facility is selected. Channel under alarm
condition will hold and will not get incremented in Auto
LI- 4104 M : 4 Channel indicator, in size 9696 mm
mode. When the digit is set as '0', alarm channel will not
with 2 set points & alarm relays
hold even in Auto mode. So select first digit either 0 or 1
as per your requirement.
LI- 4108 A : 8 Channel indicator, in size 19296 mm
without any set point & alarm relay

* LRC - Line Resistance Compensation


** CJC - Cold Junction Compensation

DIGICONT, 6-F, Industrial Estate, KOTA - 324007 (INDIA)


Tel./Fax : 91-744-2450568 e-mail : digicont@kappa.net.in
Digital Process Indicator
Models : L I- 4113 / DPC4131

Features
4 Microcontroller based
4 Bright red 0.6 LED display
4 Accepts 4-20 mA or any other mA dc input
4 Programmable Range
4 24V dc output available for feeding transmitter
4 Alarm / Trip relay outputs
4 Supply 90-270V AC
4 Program retention through EEprom

Digicont offers a range of Digital Process Indicators for process


new industries. Equipped with field programmable range, the alarms setting is
Digital. Thus, unlike other controllers which have Potentiometer / Thumb wheel
setting, it gives high control accuracy. Set data is retained using EEprom instead
of battery. 24V DC supply output is available for feeding the mA dc signal
transmitter.
These instruments are available in various DIN sizes and can therefore
easily replace existing old technology instruments.

new
Specifications L I - 4113 DPC4131
Type Microcontroller based Microcontroller based
Display 4 digit, 0.6, Red, LED 5 digit, 0.6, Red, LED
Range & Decimal point Programmable Programmable
Pre-programmed Ranges Not Available 2 pre-programmed ranges selectable
i) Std -1 4-20 mA = 0 - 100
ii) Std -2 4-20 mA = 4.0 - 20.0
Calibration By Software By Software
Accuracy +0.25% F.S +1 count +0.25% F.S +1 count
Alarm O/P Dual Dual
Indication 2 LED lamp on front 2 LED lamps on front
Contacts 2 C/o, 5.0 Amp, 230V AC 2 C/o, 2.0 Amp, 230V AC
Hysteresis Programmable Programmable
Hi / Lo type Programmable Programmable
Setting / Programing by front Keypad by front Keypad

Power supply 110 / 220 VAC 90 - 270 VAC, 50 Hz


Ambient 0 to 50 oC 0 to 50 oC
Humidity Upto 95% Rh Upto 95% Rh
Case ABS plastic molded ABS plastic molded
Bezel 96(W) x 96(H) x 150(D) 96(W) x 48(H) x 120(D)
Panel Cut-out 92(W) x 92(H) 92(W) x 45(H)

Tel : 917442450568 / 2364612


Fax : 917442450568
e-mail : digicont@kappa.net.in 6-F, Industrial Estate,
Website : www.digicont.co.in KOTA - 324 007 (INDIA)
Digital Temperature Scanner
MODEL : Digiscan 3116 - M

Digicont make Digital Temperature Scanner, Digiscan Model : 3116-


FEATURES : M is microprocessor based instrument and is a result of continuous
Microprocessor based development in the field of Instrumentation Technology. It has been
designed keeping reliability, good appearence and easy maintenance
technology in view. Well planned layout with plug-in type modular construction of
Scanning by solid state PCBs reduces down-time.
switches. 3116-M is meant to Scan, Monitor and Control upto maximum 16-
Operation & Programming from inputs. Both, Auto or Manual channel selection facility is available.
The channel inputs can be from RTDs or Thermocouples. However,
front panel Keyboard. single type of sensors must be connected to all inputs. Bright, 7-
Led indicators for Alarm & Trip segment LED displays give distant visibility of Temperature Reading
for each Input and Channel number. Alarm/Trip indications are indicated by LED
lamps for each channel separately.
Battery back-up for Programmed
Temperature is monitored with grouped relay outputs associated with
data individual LED indication. Setting can be adjusted independently over
Software Linearisation. full span, for each channel. System is also available with single Set-
Relibility & stability even under point & Control OR without any Set-point & Control.
high electromagnetic Front panel Keyboard provides user friendly operation and
programming facility with easily understood display prompts. A
interference. Memory Lock switch has been provided at the rear so that
Std. DIN size 144 144 and Flush unauthorised tempering with the set-points is avoided. Applications
Panel mounting. include-Motor Winding and Bearing Temperature Monitoring, Furnace
Temperature Measurements etc.
SPECIFICATION Picture shows terminals for 8-channel scanner with
Display 2-Alarm & 2-Trip relay contacts. Number of terminals
Temp. Reading : 4 digits. will vary as per actual requirment.
Channel No. : 2 digits.
Mode : 2 digits with easily understood prompts.
Range : 0-200 oC with resolution of 0.1 oC. or
0-1200 oC with resolution of 1oC.
No. of Channel : 6, 8, 10, 12 or 16.
Scanning Medium : Solid State Switches, CMOS multiplexers.
Inputs : RTDs or Thermocouples of any type. But,
same type of inputs must be connected to
all channels.
Accuracy : +/- 0.25% of range +/- 1 digit
Power Supply : 110V AC ir 230 V AC, site selectable.
No. of Set-points 2 per channel ; Alarm and Trip (Also available
with single Set-Point or without it.)
Set-points
Programming : Adjustable over the full span by front panel
keyboard.
Type of control : On-Off
Alarm Indication : By LED lamps, seperate indicators for
each channel. Yellow lamps for Alarm OPERATION
and Red lamps for Trip. Mode Switch : To select Auto, Manual, Set Alarm Set
Output Relays : 8 Nos. Maximum with 4 groups of inputs. Trip and Set Scan Rate modes. On each
Grous of inputs. Grouping details to be pressing of the switch, Mode advances to
furnished by the user while ordering. the next step.
Relay Contact Rating : One SPST contact per relay. Rated These modes are indicated at the mode -
3A - 240 VAC. display field as -
Hysterisis : 5-degrees. & respectively. In
Scan Rate : Adjustable by keyboard switches between Auto mode channel number advances
1-sec to 32 sec. automatically at the pre-set Scan Rate.
Programmed INR Switch : To increment the Ch. No. when system is
Data Retention : Alarm/Trip set values, Scan rate. Alarm in Manual or Set Modes.
status etc, is retained by battery back- & Switch : To increment / decrement the blinking
up.Battery keeps on charging when power display when the system is in set modes.
is ON. Relation time when power Off- & Switch : To right - shift or left-shift the blinking
3days. display when system is in set modes.
Sensor Linerisation : Through software. ENT Switch : To enter the set value into the memory
Line resistance when system is in set modes.
Compensation : For RTD inputs, Automatic with 3-wire ACK Switch : To acknowledge and cancel the Alarm
connection system. relays.
Cold-Junction RST Switch : To Reset the system except the set data.
Compensation : For Thermocouple inputs. Automatic CJC Lock Switch : Provided at the rear, When put in Lock
provided. position, ENT Switch is disabled.
Sensor Open
Condition : Indicated by data field as OPEN, Relays Alarm indication and Alarm Relay Contact also appear when
get deenergised. the channel Temperature is Under Range or Over Range. This is
Mounting : Flush Panel. displayed as and on the data field.
Terminals : Screw type, suitable for 1.5 sq. mm cable
at the rear of the instrument.
Dimentions in mm : Over all ; 144(H) 144(W) 300(D) cut-
out required for mounting 136(H) 136(W)
Power Consumption : 20VA 6-F, Industrial Estate, Tel : 91-744-450568, 364612
Weight : 4.0 kg KOTA - 324007, INDIA Fax : 91-744-450568, 430587
Ambient Temp. : 0 - 50 0C e-mail : digicont@kappa.net.in
Electronic Timer
DIGIDELAY SERIES - 2400 / 2000 D

APPLICATION FEATURES :
Digidelay Series 2400/2000D Timers are suitable Based on CMOS IC Technology
in applications involving reliable and accurate tim-
ing such as in Batch process, Process Control In- High Repeat Accuracy
strumentation, Motor Controls, Sequence & Inter-
lock schemes, Moulding & Welding Machines, Exceptionally Reliable & Rugged
Machinetools, Photographic and X-Ray equipment Low Power Consumption
etc.
Available in 4 - timing modes
DESCRIPTION
Circuit scheme adopts technique of CMOS IC Timing Range available from Sec. to
based clock generation and counter. Two LED in- Hrs & days.
dicators are provided on front face. One, to show
Power on and the other, to show status of timer
Rugged terminals & screws with high
output Relay. A knob is provided to preset the time quality plating and grip washer
with continuous setting.
TIMING MODES
SPECIFICATIONS
Operating voltage : 110V AC / 220V AC / 24V DC
On-delay : The output relay operates after the set
Repeat Accuracy : 1% delay from the instant the input contact is closed.
Setting Accuracy : 10%; setting range, 1 to 10,
continuous, with a multiplica- Off-delay : The output relay de-operates after the set
tion factor. delay from the instant the input contact is opened.
Reset Time : Almost Nil.
Monoshot : The output relay operates as soon as the
Contact outputs : 2 - changeover Rating - 6A, input contact is closed and de-operates automatically
250V AC (Resistive) (1 - after set time.
changeover in case of Models
242X-P/F) On-Off : The output relay operates and de-operates
Insulation : Between power or output con- with the set period. The on-off ratio shall be equal.
tacts & Body - 1.5 KV. The on/off time is set with single knob
Ambient Temp. : Upto 55 Deg. Cent.
Humidity : Upto Rh 80%
SERIES 2400
Size : 48 48 mm, Hight = 95 mm
Models : 24XX-P, available in plug-in type case alongwith Models : 24XX-F, available in Flush Panel mounting case
DIN Rail / Surface mounting Terminal socket. Terminal socket with Rear connection Terminals. Panel cutout required 4545
size 50 40 20 mm mm. Plastic Ring type mounting Clamp is supplied alongwith.

SERIES 2000
Size : 76 53 mm, Hight = 115 mm
Available in DIN Rail / Surface mounting case. Terminationat
top - level

6-F, Industrial Estate, Tel : 91-744-450568, 364612


KOTA - 324007, INDIA Fax : 91-744-450568, 430587

e-mail : digicont@kappa.net.in

You might also like