Structural Analysis Report

118' Monopole Tower

Prepared for:
Crown Castle
BU No. 877737
Pelican Bay

T-Mobile Co-Locate
Global/Beville 3019077
A2A0461A

B+T Project Number


81117.010.01
March 3rd, 2015

Hp B+T GRP

B+T Group
1717 S. Boulder, Suite 300
Tulsa, OK 74119
(918)587-4630
btwo@btgrp.com
J B+T GRP
March 3, 2015

David Robertson
r
B+T Group
Crown Castle 1717 S. Boulder, Suite 300
12725 Morris Road Extension Suite 400 Tulsa, OK 74119
Alpharetta, GA 30004 (918)587-4630
(678)366-1273 btwo@btgrp.com

Subject: Structural Analysis Report

Carrier Designation: T-Mobile Co-Locate


Carrier Site Number: A2A0461A
Carrier Site Name: Global/Beville 3019077

Crown Castle Designation: Crown Castle BU Number: 877737


Crown Castle Site Name: Pelican Bay
Crown Castle JDE Job Number: 320765
Crown Castle Work Order Number: 1016810
Crown Castle Application Number: 280411 Rev. 3

Engineering Firm Designation: B+T Group Project Number: 81117.010.01

Site Data: 2050 Beville Rd, Daytona Beach, Volusia County, FL


Latitude 29 9' 49.3", Longitude -81 3'34.2"
118 Foot - Monopole Tower

Dear David Robertson,

B+T Group is pleased to submit this "Structural Analysis Report" to determine the structural integrity of the
above mentioned tower. This analysis has been performed in accordance with the Crown Castle Structural
'Statement of Work' and the terms of Crown Castle Purchase Order Number 761389, in accordance with
application 280411, revision 3.

The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we
have determined the tower stress level for the structure and foundation, under the following load case, to be:

LC7: Existing + Reserved + Proposed Equipment Sufficient Capacity


Note: See Table 1 and Table 2 for the proposed and existing/reserved loading, respectively.

This analysis has been performed in accordance with the 2010 Florida Building Code based upon an ultimate 3-
second gust wind speed of 140 mph converted to a nominal 3-second gust wind speed of 108 mph per section
1609.3.1 as required for use in the TIA-222-G Standard per Exception #5 of Section 1609.1.1. Exposure
Category C and Risk Category II were used in this analysis.

All equipment proposed in this report shall be installed in accordance with the attached drawings for the
determined available structural capacity to be effective.

We at B+T Group appreciate the opportunity of providing our continuing professional services to you and Crown
Castle. Ifyou have any questions or need further assistance on this or any other projects please give us a call.

Respectfully submitted by:


B+T Engineering, Inc.

JNo.6<
John Landon JohnW. Kelly, P.E., S.E. r* ;
Project Engineer Vice President STAl
COA: 27496 Expires: 02-28-201'

tnxTower Report - version 6.1.4.1


NX\t\H>K"//;/y
.\N '/:

^v*

V- -10 dTATB
March 3, 2015
118 Ft Monopole TowerStructural Analysis Report CCIBU No. 877737
Project Number 81117.010.01, Application 280411, Revision 3 Page 2

TABLE OF CONTENTS

1) INTRODUCTION

2) ANALYSIS CRITERIA
Table 1 - Proposed Antenna and Cable Information
Table 2 - Existing and Reserved Antenna and Cable Information
Table 3 - Design Antenna and Cable Information

3) ANALYSIS PROCEDURE
Table 4 - Documents Provided
3.1) Analysis Method
3.2) Assumptions

4) ANALYSIS RESULTS
Table 5 - Section Capacity (Summary)
Table 6 - Tower Components vs. Capacity
4.1) Recommendations

5) APPENDIX A
tnxTower Output

6) APPENDIX B
Base Level Drawing

7) APPENDIX C
Additional Calculations

tnxTower Report - version 6.1.4.1


March 3, 2015
118FtMonopole Tower Structural Analysis Report CCIBU No. 877737
Project Number 81117.010.01, Application 280411, Revision 3 Page 3

1) INTRODUCTION

This tower is a 118 ft Monopole tower designed by Summit in May of 2001. The tower was originally designed
for a wind speed of 105 mph per TIA/EIA-222-F. This tower is modified by IETS and Sabre in February 2010
and those modifications are incorporated in this analysis.

2) ANALYSIS CRITERIA

The structural analysis was performed for this tower in accordance with the requirements of TIA-222-G
Structural Standards for Steel Antenna Towers and Antenna Supporting Structures using a 3-second gust wind
speed of 108 mph with no ice and 60 mph under service loads, exposure category C with topographic category
1 and crest height of 0 feet.

Table 1 - Proposed Antenna and Cable Information


Center
Number Number Feed
Mounting Line Antenna
of Antenna Model of Feed Line Note
Level (ft) Elevation Manufacturer
Antennas Lines Size (in)
(ft)
93.0 94.0 3 Andrew SBNHH-1D65B - -
-

Table 2 - Existing and Reserved Antenna and Cable Information


Center Feed
Number Number
Mounting Line Antenna Line
of Antenna Model of Feed Note
Level (ft) Elevation Manufacturer Size
Antennas Lines
(ft) (in)
I 3 Ericsson 800MHZ SMR FILTER
3 Ericsson RRUS 31 B25
3 Ericsson I RRUS-11 800MHz
3 Nokia | FZHJ-RRH
3 1 3/16
120.0 120.0 3 Nokia RADAR FILTER 1
1 5/8
9 | Rfs Celwave ACU-A20-N
3 | Rfs Celwave | APXVERR18-C
3 j TongyuCommn. | TYDA-252718DER4-65P
1 j - | T-Arm Mount [TA 602-3]
3 j CSS | AXP19-60-2 ~ ~ 2
114.0
113.0 3 f Antel BXA-70063/6CFx2
12 1 5/8
113.0 1 | T-Arm Mount [TA 602-3] 1
1 | Andrew j VHLP2-18-1WH
1 Andrew | VHLP2-11-2WH
106.0
1 j Andrew | VHLP2.5-11
6 5/16
100.0 3 Dragonwave ! Horizon DUO 3 1/2 1
3 Kathrein j 840 10054
103.0
3 | Motorola DAPVxRF
100.0 f i ! Side Arm Mount [SO 102-3]
3 | Andrew j TMBX-6517-R2M
3
3 | Andrew | TMBXX-6517-A2M
~ -

94.0
93.0
3 | Andrew | TMBXX-6517-A2M 1 1 3/5
1
93.0 1 __

T-Arm Mount [TA 602-3] 6 1 1/4

tnxTower Report - version 6.1.4.1


March 3, 2015
118 Ft Monopole Tower Structural Analysis Report CCIBU No. 877737
Project Number 81117.010.01, Application 280411, Revision 3 Page 4

Center
Number Feed
Mounting Line Antenna Number
of Line
Level (ft) Elevation Antenna Model of Feed Note
Manufacturer Size
Antennas Lines
(ft) (in)
Nokia TME-FRIG
Nokia TME-FXFB
91.0 91.0
Raycap TME-ASU9338TYP01
1 Pipe Mount [PM 601-3]
Notes:
1) Existing Equipment
2) Reserved Equipment
3) Equipment To Be Removed

Table 3 - Design Antenna and Cable Information


Center
Number Number Feed
Mounting Line Antenna
of Antenna Model of Feed Line
Level (ft) Elevation Manufacturer
Antennas Lines Size (in)
(ft)
3 Generic T-Arm
118 118 - -

9 Decibel DB948F65E-M
1 Generic 14' LP Clamp Platform I
100 100
! 12 Dapa 48000 i I
! j
80 wn
1 Generic | 14' LP Clamp Platform
12 | Dapa 48000 i

3) ANALYSIS PROCEDURE

Table 4 - Documents Provided

Document Remarks Reference Source

Online Application T-Mobile Co-Locate Revision # 3 280411 CCI Sites


Summit Manufacturing, Inc.
Tower Manufacturer Drawing 1548523 CCI Sites
Drawing No. 14075-D1
Tower Modification Drawing IETS, Drawing. No. 2010-70019 2592390 CCI Sites
Post Modification Inspection IETS, Project. No. 2010-70191 2699677 CCI Sites

Foundation Drawing
Summit Manufacturing, Inc. I
Job No. 29201-0509 j ^"4b4l CCI Sites
i

Geotech Report j UES, Project No. 45291-001-01 j 1549663 CCI Sites


Antenna Configuration Crown CAD Package jDate: 02/27/2015 CCI Sites

3.1) Analysis Method

tnxTower (version 6.1.4.1), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.

tnxTower Report - version 6.1.4.1


March 3, 2015
118 Ft Monopole TowerStructural Analysis Report CCI BU No. 877737
Project Number 81117.010.01, Application 280411, Revision 3 Page 5

3.2) Assumptions

1) Tower and structures were built in accordance with the manufacturer's specifications.
2) Thetower and structures have been maintained in accordance with the manufacturer's
specification.
3) The configuration of antennas, transmission cables, mounts and other appurtenances are as
specified in Tables 1 and 2 and the referenced drawings.
4) Mount areas and weights are assumed based on photographs provided.
This analysis may be affected if any assumptions are not valid or have been made in error. B+T
Group should be notified to determine the effect on the structural integrity ofthe tower.

4) ANALYSIS RESULTS

Component Critical SF*P allow %


Section Size P(K) Pass / Fail
Elevation (ft) Element (K) Capacity
No. Type
TP29.63x22x0.219 1 -8.102 1365.400 62.8 Pass
L1 118-76.75 Pole

TP35.9x28.499x0.25 2 -13.626 1850.790 94.1 Pass


L2 76.75 - 40.5 Pole

TP39.561x34.567x0.313 3 -19.528 2707.090 86.6 Pass


L3 40.5-18 Pole

TP42.89x39.561x0.458 4 -24.642 2892.690 93.6 Pass


L4 18-0 Pole
iSummaryj
Pole(L4) ! 94.1 Pass

Table 6 - Tower Component Stresses vs. Capacity - LC7


Notes Component Elevation (ft) % Capacity Pass / Fail

Anchor Rods Base 75.8 Pass

Base Plate Base 75.4 Pass

Base Foundation Base 75.4 Pass

Structure Rating (max from all components) = 94.1%

Notes
D
See additional documentation in "Appendix C- Additional Calculations" for calculations supporting the %capacity
consumed.
2) Capacities up to 105% are considered acceptable based on analysis methods used.

4.1) Recommendations

The tower and its foundation have sufficient capacity to carry the existing, reserved, and proposed
loads. No modifications are required at this time.

tnxTower Report - version 6.1.4.1


APPENDIX A

TNXTOWER OUTPUT
DESIGNED APPURTENANCE LOADING
TYPE ELEVATION TYPE ELEVATION
Lightning Rod 3/4" x 8' (E) 122 AXP19-60-2 vil Mount Pipe (R) 113
APXVERR18-C w/ Mount Pipe (E) 120 7'x2" Antenna Mount Pipe (E) 113
APXVERR18-C w/ Mount Pipe (E) 120 7'x2" Antenna Mount Pipe (E) 113
APXVERR18-C w/ Mount Pipe (E) 120 7'x2" Antenna Mount Pipe (E) 113
TYDA-252718DER4-65P w/ Mount 120 T-ArmMount [TA602-3] (E) 113
Pipe (E)
840 10054 w/ Mount Pipe (E) 100
TYDA-252718DER4-65P w/ Mount 120 840 10054 w/ Mount Pipe (E) 100
Pipe (E)
840 10054 w/ Mount Pipe (E) 100
TYDA-252718DER4-65P w/ Mount 120
Pipe (E) DAP Vx RF (E) 100

DAP Vx RF (E) 100


RRUS-11 800MHz (E) 120
DAP Vx RF (E) 100
RRUS-11 800MHz (E) 120
RRUS-11 800MHz (E) Horizon DUO (E) 100
120
Horizon DUO (E) 100
(3) ACU-A20-N (E) 120

(3) ACU-A20-N (E) Horizon DUO (E) 100


120
6' x 2" Mount Pipe (E) 100
(3) ACU-A20-N (E) 120
6' x 2" Mount Pipe (E) 100
RRUS31 B25(E) 120
6' x 2" Mount Pipe (E) 100
RRUS31 825(E) 120
RRUS31 B25(E) Side Arm Mount [SO 102-3] (E) 100
120
VHLP2-11-2WH(E) 100
800MH2 SMR FILTER (E) 120

800MHZ SMR FILTER (E) 120


VHLP2.5-11 (E) 100
800MHZ SMR FILTER (E) 120
TMBXX-6517-A2M vil Mount Pipe (E) 93
RADAR FILTER (E) 120
TMBXX-6517-A2M w/ Mount Pipe (E) 93
RADAR FILTER (E) 120
TMBXX-6517-A2M vil Mount Pipe (E) 93
RADAR FILTER (E) 120
FZHJ-RRH (E) T-Arm Mount [TA602-3] (E) 93
120
FZHJ-RRH (E) SBNHH-1D65B vil Mount Pipe (P) 93
120
SBNHH-1D65BW/Mount Pipe (P) 93
FZHJ-RRH (E) 120

(2) 61x 2' Mount Pipe (E) SBNHH-1D65Bw/Mount Pipe (P) 93


120
(2) 6' x 2 Mount Pipe (E) TME-FXFB vil Mount Pipe (E) 91
120
(2) 6' x 2 Mount Pipe (E) TME-FXFB vil Mount Pipe (E) 91
120
TME-ASU9338TYP01 vil Mount Pipe 91
T-Arm Mount (TA602-3] (E) 120
(E)
BXA-70063/6CFx2 w/ Mount Pipe (E) 113
Pipe Mount [PM 601-3] (E) 91
BXA-70063/6CFx2 w/ Mount Pipe (E) 113
TME-FRIG (E) 91
BXA-70063/6CFx2 w/ Mount Pipe (E) 113
TME-FRIG (E) 91
o AXP19-60-2 w/ Mount Pipe (R) 113
TME-FRIG (E) SI
AXP19-60-2 w/ Mount Pipe (R) 113

MATERIAL STRENGTH
GRADE Fy Fu GRADE Fy Fu
A572-55 65 ksi 80 ksi 41.049463ksi 41 ksi 55 ksi

TOWER DESIGN NOTES


1. Tower is located in Volusia County, Florida.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 108 mph basic wind in accordance with the TIA-222-G Standard.
4. Deflections are based upon a 60 mph wind.
5. Tower Structure Class II.
6. Topographic Category 1 with Crest Height of 0.000 ft
7. TOWER RATING: 94.1%

ALL REACTIONS
ARE FACTORED

SHEAR" , MOMENT
26K ( r \ 2337 kip-ft
TORQUE 1 kip-ft
REACTIONS - 108 mph WIND

r- B+T Group 101'81117.010.01 - Pelican Bay, FL (BIM 8777X


*=J13 1717 S Boulder, Suite 300 Project: App'd:
b*tgrp Tulsa, OK 74119 Client: Crown Castle Drawn by jlandon
Code: T|A_222-G Date: 03/03/15 Scale: NTS
Phone: (918)587-4630
FAX: (918)295-0265 Path: Dwg No. p_.<
TIA-222-G -108 mph Exposure C Maximum Values
Vx Vz Mx Mz

Global Mast Shear (K) cSI ol Da I VI ast Mom erIt (cip-1Ft)

]j '\
5 5( 0 5 50 1C 00 1. 00 2C 00 2! 00
118.00C
118 000

76.750 76750

C
o
'+-"
03
>

.:;:: i _ . J _ _ _ J _ _ j - J _ _ J - J _ J _ J _ 4
40.500
\ -

18.000 18.000

0.000
\ \\ 50 :::
0.000

P B+T Group 'ob 81117.010.01 - Pelican Bay, FL (BU# 87773]


^.p3 1717 SBoulder, Suite 300 Project
Drawn by: j|andon App'd
bvtgrp Tulsa, OK 74119 Clienl Crown Castle
Dale: 03/03/1 5 Scale NTS
Phone: (918) 587-4630 Code TIA-222-G
FAX: (918) 295-0265
Path JDwgNo. p_
TIA-222-G - Service - 60 mph Maximum Values

Defied ion (in) Tilt(deg) Twist (deg)


) 5 10 15 2C ) 0 05 0 1
118 00C 118.000

>\ i;;

76.75( I _ J L I L I 1 L 76.750

c
o

03
>

LU

4050C _ 1_ J. _l _ u . _i _ u j. _i _ _ _L _l_ U J. _
_
_-L i_
i

40.500

1800( 18.000

)000
0000

) 0. )5 0 1

r- B+T Group m 81117.010.01 - Pelican Bay, FL (BU#87773',


^j113 1717 SBoulder, Suite 300 Project:
Drawn by. j|andon App'd
b'Tgrp Tulsa, OK 74119 Cl,enl; Crown Castle
code: T|A_222-G Dale: 03/03/15 Scale: NTg
Phone: (918)587-4630
Path: Dwg No.p e
FAX: (918)295-0265
Feed Line Distribution Chart
0'-118'
App Out Face Truss Leg

118.000
Face A Face B Face C

113.000 113.000

100.000 100.000

93.000 93.000

76.750

S
^
^ CO

w
0
1 Gj"
c
<
o ST
3 < "?
15 0
03 <
c >-
| j 0
>
0 0
u? t/1 0

HI
</)

Si ^
2
<
o

6 O
a 111

40.500 n 40.500

20.000 20.000

18.000 18.000

' ' *


5j
a a 5!

0.000 0.000

/HT Group 81117.010.01 - Pelican Bay, FL (BU# 87773]


=r;p3 1717 S Boulder, Suite 300 Project:
App'd:
a" Tulsa, OK 74119 Crown Castle D,awnby:ilandon
Phone: (918) 587-4630 Code: T|A_222-G ^_ 03/03/15 NTS
Path Dwg No.
FAX: (918)295-0265 E-7

Job
Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 1 Of 11

Project Date
B+T Group
09:15:22 03/03/15
1717SBoulder. Suite 300
Tulsa. OK 74119 Client Designed by
Phone: (918) 587-4630 Crown Castle jiandon
FAX: (918) 295-0265

Tower Input Data

There is a pole section.


This tower is designed using the TIA-222-G standard.
The following design criteria apply:
Tower is located in Volusia County, Florida.
Basic wind speed of 108 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.000 ft.
Deflections calculated using a wind speed of 60 mph.
TOWER RATING: 94.1%.
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.

Options 3
Consider Moments - Legs Distribute Leg Loads As Uniform Treat Leedline Bundles As Cylinder
Consider Moments -1 lorizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals Assume Rigid Index Plate Calculate Redundant Bracing Forces
Use Moment Magnification Use Clear Spans For Wind Area Ignore Redundant Members in FEA
Use Clear Spans Lor kl./r SR Leg Bolts Resist Compression
V Use Code Stress Ratios
V Use Code Safety Factors- Guys Relcnsion GuysTo Initial Tension All Leg Panels Have Same Allowable
Bypass MastStability Checks Offset Gin At Foundation
Escalate Ice
Use Azimuth Dish Coefficients Consider Feedline Torque
Always Use Max kz
Use Special Wind Profile Project Wind Area of Appurt. Include Angle Block Shear Check
Autocalc Torque Arm Areas Poles
Include Bolts In Member Capacity
SR Members Have Cut Ends Include Shear-Torsion Interaction
LegBolts Arc AtTop Of Section
Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination Use TIA-222-G Tension Splice Capacity
Exemption

Tapered Pole Section Geometry


Section Elevation Section Splice Number Top Bottom Wall Bend Vole Grade
Length Length of Diameter Diameter Thickness Radius
ft Sides in in__ in '
" A572-65
22.000 29.630 0.219 0.875
"LI 118.000-76.750 41.250 3.750 18
(65 ksi)
28.499 35.900 0.250 1.000 A572-65
1.2 76.750-40.500 40.000 4.500 18
(65 ksi)
34.567 39.561 0.313 1.250 A572-65
L3 40.500-18.000 27.000 0.000 18
(65 ksi)
39.561 42890 0.458 1 831 41.049463ksi
1.4 18.000-0.000 18.000 18
(41 ksi)
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 2 of 11

Project Date
B+T Group
! 1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Designed by
Phone: (918) 587-4630 Crown Castle
FAX: (918) 295-0265 jiandon

Tapered Pole Properties


Section Tip Dia. Area 1 r C 1/C J It/Q w w/t
in itr in' in in in in4 iir in
LI 22.339 15.123 906.444 7.732 11.176 81.106 1814.080 7.563 3.487 15.941
30.087 20.421 2231.685 10.441 15.052 148.265 4466.306 10.212 4.830 22.079
1.2 29.643 22.415 2259.890 10.028 14.477 156.098 4522.754 11.210 4.576 18.303
36.454 28.288 4542.166 12.656 18.237 249.060 9090.308 14.147 5.878 23.514
1.3 35.946 33.977 5036.878 12.160 17.560 286.834 10080.384 16.992 5.534 17.708
40.171 38.930 7576.382 13.933 20.097 376.991 15162.734 19.468 6.413 20.521
1.4 40.171 56.815 10975.544 13.882 20.097 546.130 21965.531 28.413 6.157 13.45
43.552 61.652 14024.179 15.063 21.788 643.662 28066.811 30.832 6.743 14.73

Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness -'/ Factor Stitch Bolt Stitch Bolt
(perfac e) Ar Spacing Spacing
Diagonals Horizontals
fi fl: in in in
LI 1 1 1
118.000-76.75
0
L2 1 1 1
76.750-40.500
L3 1 1 1
40.500-18.000
L4 1 1 0.977705
18.000-0.000

Feed Line/Linear Appurtenances - Entered As Round Or Flat


Description Sector Component Placement Toial Number Start/End Widthor Perimeter Weight
Type Xumbe, Per Row Position Diameter
f in in klf
*$SS*
LC6-50(1 1/4") C Surface Ar 93.000 - 0.000 7 4 -0.500 1.530 0.001
(E) (CaAa) 0.400
*$$$*
Safety Line 3/8 A Surface Ar 118.000-0.000 1 1 -0.500 0.375 0.000
(E) (CaAa) -0.500
*s$s*
1" Plate C Surface Af 20.000 - 0.000 1 1 -0.100 6.000 14.000 0.000
(E) (CaAa) 0.100
1" Plate A Surface Af 20.000 - 0.000 1 1 -0.100 6.000 14.000 0.000
(H) (CaAa) 0.100
1" Plate B Surface Af 20.000 - 0.000 1 1 -0.100 6.000 14.000 0.000
(E) (CaAa) 0.100
*$ss*

Feed Line/Linear Appurtenances - Entered As Area


Description Face lllow Component Placement Total CMa Weight
or Shield Type Numhei
Leg f fM klf
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 3 of 11

Project Date
B+T Group
1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Designed by
Phone: (918) 587-4630 Crown Castle
FAX: (918) 295-0265 jiandon

Description Face Allow Component Placement Total CaAa Weight


or Shield Type Number
U'g ft fr/fi kit
TSZ 999 c No Inside Pole 118 000 - 0.000 3 No Ice 0.000 0.001
067/xxxM-8AWG(
1-3/16")
(E)
FIBER ONLY CABLE c No Inside Pole 118.000-0.000 1 No Ice 0.000 0.000
16(5/8")
(E)
*sss*
LDF7-50A( 1-5/8") c No Inside Pole 113.000-0.000 12 No Ice 0.000 0.001
(E)
*$$$*
2" Riuid Conduit A No Inside Pole 100.000-0.000 1 No Ice 0.000 0.003
(E)
LDI;4-50A(l/2") A No Inside Pole 100.000-0.000 -> No Ice 0.000 0.000
(E-Inside Conduit)
RG-11(5/16") A No Inside Pole 100.000-0.000 6 No Ice 0.000 0.000
(L-Inside Conduit)
*sss*

Feed Line/Linear Appurtenances Section Areas


Tower Tower Face Ah AF CaAa CaAa Weight
Section Elevation In Face Out Face
ft f': fr f': ft2 K
LI 118.000-76.750 A 0.000 0.000 1.547 0.000 0.097
B 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 9.945 0.000 0.578
L2 76.750-40.500 A 0.000 0.000 1.359 0.000 0.145
1! 0.000 0.000 0.000 0.000 0.000
C 0.000 0.000 22.185 0.000 0.657
L3 40.500-18.000 A 0.000 0.000 2.844 0.000 0.090
1? 0.000 0.000 2.000 0.000 0.000
C 0.000 0.000 15.770 0.000 0.408
1.4 18.000-0.000 A 0.000 0.000 18.675 0.000 0.072
B 0.000 0.000 18.000 0.000 0.000
C 0.000 0.000 29.016 0.000 0.326

Feed Line Center of Pressure

Section Elevation CPx CPz CPx CP,


Ice Ice
ft in in in in

LI 118.000-76.750 -0.003 0.4 11 -0.003 0.411


L2 76750-40.500 0.046 0.830 (1046 0.830
L3 40.500-18.000 0.043 0.786 0.043 0.786
L4 18.000-0.000 0.027 0.491 0.027 0.491

Shielding Factor Ka
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 4 of 11

Project Date
B+T Group
1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Designed by
Phone: (918) 587-4630 Crown Castle
FAX: (9IS) 295-0265 jiandon

Tower Feed Line Description Feed Line K.. K:


Section Record No. Segment Elev. No Ice Ice
LI 10 LC6-50(I 1/4") 76.75 - 93.00 1.0000 1.0000
LI 13 Safety Line 3/8 76.75- 118.00 1.0000 1.0000
L2 10 EC6-50(I 1/4") 40.50 - 76.75 1.0000 1.0000
L2 13 Safety Line 3/8 40.50-76.75 1.0000 1.0000
L2 15 1" Plate 40.50 - 20.00 1.0000 1.0000
L2 16 1" Plate 40.50 - 20.00 1.0000 1.0000
L2 17 I" Plate 40.50 - 20.00 1.0000 1.0000
L4 10 EC6-50(I 1/4") 0.00 - 18.00 1.0000 1.0000
L4 13 Safety Line 3/8 0.00- 18.00 1.0000 1.0000
1.4 15 1" Plate 0.00- 18.00 1.0000 1.0000
L4 16 1" Plate 0.00- 18.00 1.0000 1.0000
1.4 17 1" Plate 0.00- 18.00 1.0000 1.0000

Discrete Tower Loads

Description Face Offset Offsets: Azimuth Placement CaAa CaAa Weight


or Type Hoi- Adjustment Front Side
Leg Lateral
Vert
fi
fi ft2 fi2 K

ft
Lightning Rod 3/4" x 8' C None 0.000 122.000 No Ice 0.600 0.600 0.030
(E)
**//**
APXVERR18-Cw/Mount A From Leg 4.000 0.000 120.000 No Ice 8.498 6.946 0.076
Pipe 0.000
(E) 0.000
APXVERR18-Cw/ Mount B From Leg 4.000 0.000 120.000 No Ice 8.498 6.946 0.076
Pipe 0.000
(E) 0.000
APXVLRR18-Cw/ Mount C From Leg 4.000 0.000 120.000 No Ice 8.498 6.946 0.076
Pipe 0.000
(E) 0.000
TYDA-25271SDLR4-65P w/ A From Leg 4.000 0.000 120.000 No Ice 8.301 5.492 0.077
Mount Pipe 0.000
(E) 0.000
TYDA-252718DER4-65P w/ B From Leg 4.000 0.000 120.000 No Ice 8.301 5.492 0.077
Mount Pipe 0.000
(E) 0.000
TYDA-252718DER4-65P w/ C From Leg 4.000 0.000 120.000 No Ice 8.301 5.492 0.077
Mount Pipe 0.000
(E) 0.000
RRUS-11 800MHz A From Leg 4.000 0.000 120.000 No Ice- 2.942 1.521 0.054
(E) 0.000
0.000
RRUS-11 800MHz B From Leg 4.000 0.000 120.000 No Ice 2.942 1.521 0.054

(E) 0.000
0.000
RRUS-11 800MHz C From Leg 4.000 0.000 120.000 No Ice 2.942 1.521 0.054
(E) 0.000
0.000
(3) ACU-A20-N A From Leg 4.000 0.000 120.000 No Ice 0.078 0.136 0.001

(E) 0.000
0.000
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 5 of 11

Project Date
B+T Group
1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Designed by
Phone: (9IS) 587-4630 Crown Castle
FAX: (9IS) 295-0265 jiandon

Description Face Offset Offsets: Azimuth Placement Cut., CaAa Weight


or Type Hon Adjustment Front Side
Leg Lateral
Vert
o

ft ft f2 ft2 K
ft
ft
(3) ACU-A20-N B From Leg 4.000 0.000 120.000 No Ice 0.078 0.136 0.001
(E) 0.000
0.000
(3)ACU-A20-N C From Leg 4.000 0.000 120.000 No Ice 0.078 0.136 0.001
(E) 0.000
0.000
RRUS31 B25 A From Leg 4.000 0.000 120.000 No Ice 1.893 1.492 0.056
(E) 0.000
0.000
RRUS31 B25 B From Leg 4.000 0.000 120.000 No Ice 1.893 1.492 0.056
(E) 0.000
0.000
RRUS3I B25 C From Leg 4.000 0.000 120.000 No Ice 1.893 1.492 0.056
(E) 0.000
0.000
800MIIZ SMR FILTER A From Leg 4.000 0.000 120.000 No Ice 0.758 0.254 0.009
(E) 0.000
0.000
800MIIZ SMR FILTER B From Leg 4.000 0.000 120.000 No Ice 0.758 0.254 0.009
(!:) 0.000
0.000
800MHZSMR FILTER C From Leg 4.000 0.000 120.000 No Ice 0.758 0.254 0.009
(E) 0.000
0.000
RADAR FILTER A From Leg 4.000 0.000 120.000 No Ice 1.143 0.314 0.022
(E) 0.000
0.000
RADAR FILTER B From Leg 4.000 0.000 120.000 No Ice 1.143 0 314 0.022
(E) 0.000
0.000
RADAR FILTER C From Leg 4.000 0.000 120.000 No Ice 1.143 0.314 0.022
(E) 0.000
0.000
FZHJ-RRH A From Leg 4.000 0.000 120.000 No Ice 1.472 1.184 0.055
(E) 0.000
0.000
FZHJ-RRH B From Leg 4.000 0.000 120.000 No Ice 1.472 1.184 0.055
(E) 0.000
0.000
FZHJ-RRH C From Leg 4.000 0.000 120.000 No Ice 1.472 1.184 0.055
(E) 0.000
0.000
(2) 6'x 2'Mount Pipe A From Leg 4.000 0.000 120.000 No Ice 1.425 1.425 0.022
(E) 0.000
0.000
(2)6' x2' Mount Pipe B From Leg 4.000 0.000 120.000 No Ice 1.425 1.425 0.022
(E) 0.000
0.000
(2) 6' x 2' Mount Pipe C From Leg 4.000 0.000 120.000 No Ice 1.425 1.425 0.022
(E) 0.000
0.000
T-Arm Mount [TA 602-3] c None 0.000 120.000 No Ice 11.590 11.590 0.774
(E)
*%%%*
BXA-70063/6CFx2 w/ Mount A From Leg 4.000 0.000 113.000 No Ice 7.969 5.398 0.042
Pipe 0.000
(E) l .000
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 6 of 11

Project Date
B+T Group
1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Designed by
Phone: (918) 5S7-4630 Crown Castle
FAX: (918) 295-0265 jiandon

Description Lace Offset Offsets: Azimuth Placement CaAa CaAa Weight


or Type llorz Adjustment Front Side
Leg Lateral
1'ert
ft
f' fi fi K
ft
ft
BXA-70063/6CFx2 w/ Mount B From Leg 4.000 0.000 113.000 No Ice 7.969 5.398 0.042
Pipe 0.000
(E) 1.000
BXA-70063/6CFx2 w/ Mount C From Leg 4.000 0.000 113.000 No Ice 7.969 5.398 0.042
Pipe ()()()()

(E) 1.000
AX PI 9-60-2 w/ Mount Pipe A From Leg 4.000 0.000 113.000 No Ice- 5.085 4.941 0.038
(R) 0.000
1.000
AXP19-60-2 w/ Mount Pipe B From Leg 4.000 0.000 113.000 No Ice 5.085 4.941 0.038
(R) 0.000
1.000
AXPl9-60-2 w/ Mount Pipe c From Leg 4.000 0.000 113.000 No Ice 5.085 4.941 0.038
(R) 0.000
1.000
7'x2" Antenna Mount Pipe A From Leg 4.000 0.000 113.000 No Ice 1.663 1.663 0.026
(E) 0.000
0.000
7'x2" Antenna Mount Pipe B From Leg 4.000 0.000 113.000 No Ice 1.663 1 663 0.026
(E) 0.000
0.000
7'x2" Antenna Mount Pipe C From Leg 4.000 0.000 113.000 No Ice 1.663 1.663 0.026
(E) 0.000
0.000
T-Arm Mount [TA 602-3] C None 0.000 113.000 No Ice 11.590 11.590 0.774
(E)
*$s$*
840 10054 w/ Mount Pipe A From Leg 2.000 0.000 100.000 No Ice 5.413 2.385 0.051
(E) 0.000
3.000
840 10054 w/Mount Pipe B From Leg 2.000 0.000 100.000 No Ice 5.413 2.385 0.051
(E) 0.000
3.000
840 10054 w/Mount Pipe C From Leg 2.000 0.000 100.000 No Ice 5.413 2.385 0.051
(E) 0.000
3.000
DAP Vx RF A From Leg 2.000 0.000 100.000 No Ice 2.275 2.275 0.026
(E) 0.000
3.000
DAP Vx RF B From Leg 2.000 0.000 100.000 No Ice 2.275 2.275 0.026
(E) 0.000
3.000
DAP Vx RF C From Leg 2.000 0.000 100.000 No Ice 2.275 2.275 0.026
(E) 0.000
3.000
Horizon DUO A From Leg 2.000 0.000 100.000 No Ice 0.547 0.343 0.007
(E) 0.000
6.000
Horizon DUO B From Leg 2.000 0.000 100.000 No Ice 0.547 0.343 0.007
(E) 0.000
6.000
Horizon DUO c From Leg 2.000 0.000 100.000 No Ice 0.547 0.343 0.007
(E) 0.000
6.000
6' x 2" Mount Pipe A From Leg 2.000 0.000 100.000 No Ice 1.425 1 425 0.022
(E) 0.000
0.000
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 7 Of 11

Project Date
B+T Group
09:15:22 03/03/15
1717 S Boulder. Suite 300
Tulsa. OK 74119 Client Designed by
Phone: (918) 587-4630 Crown Castle jiandon
FAX: (91S) 295-0265

Face Offset Offsets: Azimuth Placement CaAa CaAa Weight


Description
or Type Horz Adjustment Front Side
Leg Lateral
Vert
ft fi ft2
f
ft
0.000 100.000 No Ice 1.425 .425 0.022
6' x2" Mount Pipe B From Leg 2.000
(E) 0.000
0.000
0.000 100.000 No Ice 1425 1.425 0022
6' x 2" Mount Pipe C From Leg 2.000
(E) 0.000
0.000
0.000 100.000 No Ice 3.000 3.000 0.081
SideArm Mount [SO I02-3| C None
(E)
*S$$*
4.000 0.000 93.000 No Ice 8.615 7.084 0.076
SBNIIH-1D65B \\l Mount A From Leg
Pipe 0.000
1.000
(P) 93.000 No Ice 8.615 7.084 0.076
SBNIIH-1D65B \\l Mount B From Leg 4.000 0.000

Pipe 0.000
1.000
(P) 93.000 No Ice 8.615 7.084 0.076
SBNHH-1D65B w/ Mount C From Leg 4.000 0.000

Pipe 0.000
1.000
(P) 93.000 No Ice 8.976 6.963 0.071
TMBXX-6517-A2M w/ A From Leg 4.000 0.000
Mount Pipe 0.000
1.000
(E) 6.963 0.071
TMBXX-6517-A2M w/ B From Leg 4.000 0.000 93.000 No Ice 8.976
Mount Pipe 0.000
I.000
(E)
TMBXX-65l7-A2Mw/ C From Leg 4.000 0.000 93.000 No Ice 8.976 6.963 0.071
Mount Pipe 0.000
l .000
(E) 93.000 No Ice 11.590 11.590 0.774
T-Arm Mount [TA 602-3] C None 0.000

(E)

l .000 0.000 ,000 NoIce 2.804 1.103 0.057


TME-FRIG A From Leg
0.000
(E)
0.000
Ij From Leg 1.000 0.000 91.000 NoIce 2.804 1.103 0.057
TME-FRIG
0.000
(E)
0.000
C From Leg 1.000 0.000 91.000 NoIce 2.804 1.103 0.057
TME-FRIG
0.000
(E)
0.000
91.000 No Ice 4.128 1.281 0.059
From I ,eg 1.000 0.000
TME-FXFB w/ Mount Pipe A
0.000
(E)
0.000
91.000 No Ice 4.128 1.281 0.059
From Leg 1.000 0.000
TME-FXFB w/ Mount Pipe B
0.000
(E)
0.000
From I.eg 1.000 0.000 91.000 No Ice 4.759 2.580 0037
TME-ASU9338TYP01 w/ C
Mount Pipe 0.000
0.000
(E) 91.000 NoIce 4.390 4.390 0.195
0.000
Pipe Mount [I'M 601-31 C None

(E)
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 8 of 11
Project
B+T Group Date
1717 S Boulder. Suite 300 09:15:22 03/03/15
Tulsa. OK 74119 Client
Phone: (9IS) 587-4630 Designed by
Crown Castle
FAX: (91S) 295-0265 ilandon

Dishes

Description Face Dish Offset Offsets: Azimuth 3 dli Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
I en

/' // .ft fi K
VHLP2-II-2VVH C Paraboloid From 2.000 90.000 100.000 2.I75 No Ice 3.715 0.031
(E) w/Shroud (HP) Leg 0.000
6.000
VHLP2-I8-IWH Paraboloid From 2.000 46.000 100.000 2.175 No Ice 3.715 0.031
(E) w/Shroud(HP) Leg 0.000
6.000
VHLP2 5-M Paraboloid From 2.000 19.000 100.000 2.917 No Ice 6.681 0.048
(E) w/Shroud(IIP) Leu 0.000
6.000
*sss*

Load Combinations

Comb. Description
No.
Dead Only
1.2 Dcad+1.6 Wind 0 dcg - No Ice
0.9 Dead+1.6 Wind 0 dcg - No Ice
1.2 Dead+1.6 Wind 30 deg - No Ice
0.9 Dead+1.6 Wind 30 deg - No Ice
1.2 Dead+1.6 Wind 60 deg - No Ice
0.9 Dead+1.6 Wind 60 deg - No Ice
1.2 Dead+1.6 Wind 90 deg - No Ice
0.9 Dead+1.6 Wind 90 dcg - No Ice
10 1.2 Dead+1.6 Wind 120 dcg - No Ice
11 0.9 Dead+1.6 Wind 120 deg - No Ice
12 1.2 Dead+1.6 Wind 150 deg-No Ice
13 0.9 Dead+1.6 Wind 150 deg-No Ice
14 1 2 l)cad+1.6 Wind 180 deg-No Ice
15 0 9 Dcad+1.6 Wind 180 dcg-No Ice
16 1.2Dead-f .6 Wind 210 deg-No Ice
17 0.9 Deadn .6 Wind 210 dec-No Ice
18 1.2 Dead+1.6 Wind 240 deg - No Ice
19 0.9 Dcad+1.6 Wind 240 deg - No Ice
20 1.2 Dead+1.6 Wind 270 dcg - No Ice
21 0.9 Dead+1.6 Wind 270 deg - No Ice
22 1.2 Dead+1.6 Wind 300 deg - No Ice
23 0.9 Dead+1.6 Wind 300 deg - No Ice
24 1.2 Dead+1.6 Wind 330 deg - No Ice
25 0.9 Dead+1.6 Wind 330 deg - No Ice
26 Dead+Wind 0 deg - Service
27 Dead+Wind 30 deg - Service
28 Dead+Wind 60 deg - Service
29 Dead+Wind 90 dcg - Service
30 Dead+Wind 120 deg-Service
Dead+Wind 150 deg - Service
Dead+Wind 180 deg - Service
Dead+Wind 210 deg - Service
34 Dead+Wind 240 dcg - Service
35 Dead+Wind 270 dcg - Service
36 Dead+Wind 300 deg - Service
37 Dead+Wind 330 dee - Service
Job
Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 9 of 11

Project Date
B+T Group 09:15:22 03/03/15
1717 S Boulder. Suite 300
Tulsa. OK 74119 Client Designed by
Phone: (918) 587-4630 Crown Castle jiandon
FAX: (918) 295-0265

Maximum Tower Deflections - Service Wind


Gov. III! Twist
Section Elevation Hon.
No. Deflection Load
C'omb.
fi
1 136 0.001
LI 118-76.75 15.440
0.895 0.001
L2 80.5-40.5 7.184
0.452 0.000
I 3 45- 18 2.037
0.279 0.149 0.000
L4 18-0

Critical Deflections and Radius of Curvature - Service Wind


Deflection Tilt Twist Radius of
Appurtenance Gov.
Elevation ('urvature
Load
Comb. fi
Ji 15.440 1.136 0.001 36610
122.000 Lightning Rod 3/4"x 8' 36610
15.440 1.136 0.001
120.000 APXVERR18-C w/ Mount Pipe
14.264 1.112 0.001 36610
113.000 BXA-70063/6CFx2 w/ Mount Pipe
1.077 0.001 15254
VHLP2-11-2WH 12.633
106.000 10169
11.264 1.044 0.001
100.000 840 10054 w/Mount Pipe
0.999 0.001 7321
SBNIIH-1D65B w/ Mount Pipe 9.722
93.000 6779
9.296 0.985 0.001
91.000 TME-FRIG

Maximum Tower Deflections - Design Wind


Gov. Till Twist
Section Elevation Horz.

No.
Deflection Load
('omb.
ft 0.007
89.665 24 6 610
LI 118-76.75
5.211 0.004
80.5 - 40.5 41.768 24
L2
24 2.629 0.001
45- 18 11.850
L3 0.000
1.625 24 0.866
L4 18-0

Critical Deflections and Radius of Curvature - Design Wind


Deflection Till Twist Radius of
Appurtenance Gov.
Elevation ('.urvature
Load
Comb __z>
6.610 0.007 6455
Lightning Rod 3/4" x 8' 24 89.665
122.000 0.007 6455
24 89.665 6.610
120.000 APXVERR18-C w/ Mount Pipe 6455
82.843 6.473 0.006
BXA-70063/6CFx2 w/ Mount Pipe 24
113.000 0.006 2688
24 73.383 6.271
106.000 VHLP2-11-2WH 1790
65.446 6.078 0.005
840 10054 w/ Mount Pipe 24
100.000 0.005 1287
24 56.502 5.817
93.000 SBNHH-1D65B w/ Mount Pipe 1191
54.026 5.733 0.005
TME-FRIG 24
91000
Job
Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 10 Of 11

Project Date
B+T Group
09:15:22 03/03/15
1717 S Boulder. Suite 300
Tulsa. OK 74119 Client Designed by
Phone: (9IS) 5S7-4630 Crown Castle jiandon
FAX: (9IS) 295-0265

Compression Checks

Pole Design Data "J


Kir Pu <}>/' Ratio
Section Elevation Size
P
No.
K /?P
ft
0.0 19.939 -8.102 1365 400 0 006
118-76.75(1) TP29.63x22.x0219 41.250 0.000
27.628 -13.626 1850.790 0.007
L2 76.75 - 40.5 (2) TP35.9x28.499x0.25 40.000 0.000 0.0
38.930 -19.528 2707.090 0.007
L3 40.5- 18(3) P39.561x34.567x0.313 27.000 0.000 0.0
61.652 -24.642 2892.690 0.009
L4 18-0(4) TP42.89.\39.561x0.458 18.000 0.000 0.0

Pole Bending Design Data


Mm Ratio
Section Elevation Size M 4>A/,1V Ratio tyMny
Muv
No.
kip-ft kip-fi 4>A/t kip-ft kip-ft <!>A-/m
f'
0.000 806.503 0.000
LI 118-76.75(1) TP29.63x22x0.219 502.034 806.503 0.622
0.934 0.000 1325.983 0.000
L2 76.75-40.5(2) TP35 9x28.499x0.25 1238.383 1325.983
0.000 2184.608 0.000
L3 40.5- 18(3) P39.561x34.567x0.313 1877.200 2184.608 0.859
0.000 2516.692 0.000
L4 18-0(4) TP42 89x39.561x0.458 2336.950 2516.692 0.929

Pole Shear Design Data


Ratio Actual )T Ratio
Section Elevation Size [dual
T '/'
No.
V
K K kip-ft kip-ft 7;
fi
0.028 0.117 1614.975 0.000
TP29.63x22x0.219 19.012 682.701
118-76.75(1) 2655.208 0.000
22.445 925.394 0.024 0.117
L2 76.75 - 40.5 (2) TP35.9x28.499x0.25
0.018 0.116 4374.558 0.000
TP39.561x34.567x0.313 24.831 1353.540
L3 40.5-18(3) 5039.542 0.000
1446350 0.018 0.116
L4 18-0(4) TP42.89x39.561x0.458 26.297

Pole Interaction Design Data


Ratio Comb. Allow. Criteria
Ratio Ratio Ratio Ratio
Section Elevation
May Vu T Stress Stress
No. P A/,
Ratio Ratio
>.W, <j)A/, Wn 47;
f 4.
Tl 118-76.75(1) 0.006 0.622 0.000 0.028 0.000 0.629 1.000
4.8.2 S

L2 76.75-40 5(2) 0.007 0.934 0.000 0.024 0.000 0.942 1.000
4.8.2 ^
1.000
1.3 40.5-18(3) 0 007 0.859 0.000 0.018 0.000 0.867
4.8.2 /
1.4 18-0(4) 0.009 0.929 0.000 0.018 0.000 0.937 1.000
4.8.2 l/
Job Page
tnxTower 81117.010.01 -Pelican Bay, FL (BU# 877737) 11 of 11

Project Date
B+T Group
09:15:22 03/03/15
1717 S Boulder. Suite 300

Tulsa. OK 74119 Client Designed by


Phone: (918) 5S7-4630 Crown Castle jiandon
FAX: (918) 295-0265

Ratio Ratio Ratio Ratio Comb. Allow. ('riteria


Section Elevation Ratio
A/, Stress Stress
No. P.,
Ratio Ratio
ft hPj, 4>.U j>A/m 11" Mu

Section Capacity Table


('ritical Ol'all.m % Pass
Elevation ( omponenl Size
Section K C'opacity Fail
Type Element
No. f
'TP29.63x22x0.2l9 -8.102 1365.400
LI 118-76.75 Pole
TP35.9x28.499xO.25 -13.626 1850.790 **
L2 76.75 - 40.5 Pole
TP39.561x34.567x0.313 -19.528 2707.090
L3 40.5- 18 Pole
TP42.89x39.561x0.458 -24.642 2892690
L4 18-0 Pole
Summary
Pole (1.2) 94.1 Pass
RATING = 94.1 Pass

**See Appendix C for calculated capacities.

Program Version 6.1.4.1


APPENDIX B

BASE LEVEL DRAWING


(INSTALLED-BUNDLED IN A 2" CONDUIT)
(3) 1/2" TO 100 FT LEVEL
(6) 5/16" TO 100 FT LEVEL

(INSTALLED)
(1) 5/8" TO 120 FT LEVEL
(3) 1-3/16" TO 120 FT LEVEL

(INSTALLED)
(12) 1-5/8" TO 113 FT LEVEL

(INSTALLED)
(6) 1-1/4" TO 93 FT LEVEL
(1) 1-3/5" TO 93 FT LEVEL-

BUSINESS UNIT: 877737


APPENDIX C

ADDITIONAL CALCULATIONS
Reinforcement J
R. nforcement 2
",- t)L-i:t-mr-.! 1 QTY Typo Petition Gap I.-n/. MIH1
QTY Typo Poilllon Gap Ttn/Comp Bottom Top
Gap Ttn/Co Bottom Top
TVP P 0 T&C
0 0
T&C 0 0 T&C
T&C
T&C 0 T&C
0 T&C
T&C 0 T&C
0 T&C
T&C T&C
0 T&C
T&C 0 T&C
0 T&C
T&C T&C
0 T&C
T&C 0 T&C
0 T&C
T&C TEC
CI rec
T&C
triulvalent Equivalent lorn Top
Original Reinlorced Section Top Shalt Eo.ulv.Lnt Weight Elevation Novation Section
Relnf. 2 Rein. 2 Relnl. 3
Bottom Top Orijhul Oilcinal Ultimate Shalt Pelnl. 1 Re Inf. 1 Ml Thlcknell Shalt Fy Mult. lira failure Failures
Top Height length Up Splice of Side* Dlametei
QTY Typo Typo Cp.<lty TYPO
Elevation llevation DillkMli YteldSiren Siren Capacity 118.0000 41.2500 3.7500 220000 296300 0 2188 65 0 1.00
76.7500 118.0000 0.218S 60 SO 62.8N 80.5000 40.0000 4.5000 284989 359000 02500 650 1.00
40.5000 80.5000 0.2500 65 80 94.M 450000 27.0000 00000 34.5674 39.5609 0.3125 65 0 100
130000 45.0000 0.3125 65 80 86.6S 18 0000 13.0000 0.0000 395609 428900 04578 401 0.98
0.0000 1SO000 0.3125 65 80 74.3%
Reinl Flats (Used for relative orientation only. Actual flat numbers may vary.)
Bottom Top Qty Model Position T or T&C 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Position T or T&C
AcroSotutions llc
Reinforcement Capacity
3

Dimensions and Properties

MowtbU
Ccntrold
Slender. Slendc Axial w/ Design A*i.il
Centrokl (rom Bolt Web Flange Hole
Ratio Unbraced Ratio Unbraced ilowable increase Governing Strength Govemin
Moment of Moment ol from Mating Hole Center Thickness Flange Thickness Diameter Yield Stress Ultimate
Weight A.ial(k. A.I.I [tip| Aial
Width (in) [in] Stress (ksi) Coellident Length (in) Coefficient Length (In)
|lb/H) Inertia (in*) Inertia (In*) Edge (In) (in) |in) Width (In) I'")
Rupture
050 1800 O.S

1/3/201$ 9.09 AM
S.\Pro;erts\CrownCojrMSin7_oV77J7_PeKconBovl^
Square, Stiffened / Unstiffened Base Plate, Any Rod Material - Rev. F /(
Assumptions: 1)Rod groups at corners. Total # rods divisible by 4. Maximum total # ofrods =48 (12 perCorner).
2) Rod Spacing = Straight Center-to-Center distance between any (2) adjacent rods (same corner)
3) Clearspace between bottom of leveling nut and top of concrete not exceeding (1)*(Rod Diameter)
Site Data Base Reactions "
BU#: 877737 TIA Revision: G
Site Name: PELICAN BAY Factored Moment, Mu: 2336.94993 ft-kips
App #: 280411 Revision # 3 Factored Axial, Pu: 24.6419 kips
Anchor Rod Data Factored Shear, Vu: 26.297038 kips
Eta Factor, n 0.5 TIA G (Fig. 4-4)
Qty: 12
Diam: 2.25 in Anchor Rod Results
Rod Material: A615-J TIA G -> Max Rod (Cu+ Vu/n.): 197.2 Kips
Yield, Fy: 75 ksi Axial Design Strength, $*Fu*Anet: 260.0 Kips
Strength, Fu: 100 ksi Anchor Rod Stress Ratio: 75.8% Pass
Bolt Circle: 49 in
Anchor Spacing: in

Plate Data Base Plate Results Flexural Check


W=Side 48 in Base Plate Stress: 37.3 ksi
Thick 2.5 in PL Design Bending Strength, <*Fy: 49.5 ksi
Grade 55 ksi Base Plate Stress Ratio: 75.4% Pass
Clip Distance in
N/A - Unstiffened
Stiffener Data (Welding at both sides) Stiffener Results
Configuration: Unstiffened Horizontal Weld : N/A
Weld Type: Vertical Weld: N/A
Groove Depth: in** Plate Flex+Shear, fb/Fb+(fv/Fv)A2: N/A
Groove Angle: degrees Plate Tension+Shear, ft/Ft+(fv/Fv)A2: N/A
Fillet H. Weld: <-- Disregard Plate Comp. (AISC Bracket): N/A
Fillet V.Weld: in Pole Results
Width: in Pole Punching Shear Check: N/A
Height: in Max PL Length

Thick: in
Notch: in
THICKNESS
Grade: ksi
Weld str.: ksi

Pole Data
Diam 42.89 in

Thick 0.3125 in nput Clear Space


3t B.C. for Single
Grade 65 ksi Anchor Case

# of Sides "0" IF Round

{Input Clear Spoce)

" Note: for complete joint penetration groove welds the groove depth must be exactly 1/2 the stiffener thickness for calculation purposes

CCIplate 1.5 - Square Base F-G 1.2, Effective March 19, 2012 Analysis date: 3/3/2015
CCI Foundation Tool Suite - Monopole Pier
CCIFTS 1.2.108.14286 - Phase 1-2
Date: 3/3/2015

BU: 877737
Site Name: Pelican Bay, FL
App Number: 280411 Revision S3 CROWN
Work Order: CASTLE

Monopole Drilled Pier

Input
Criteria
TIA Revision: G
ACI 318 Revision: 2008
Seismic Category:

Forces
Compression 25 kips
Shear 26 kips
Moment 2337 k-ft
Swelling Force 0 kips

Foundation Dimensions
Pier Diameter: 6 ft
Ext. above grade: 0.5 ft
Depth below grade: 24.5 ft
(16) -#11

Material Properties
Number of Rebar: 16
Rebar Size: 11
Tie Size 5
Rebar tensile strength: 60 ksi
Concrete Strength: 3000 psi
Ultimate Concrete Strain 0.003 in/in
Clear Cover to Ties: 4 in

Soil Profile: Soil

Ultimate Ultimate Ultimate


Friction Uplift Skin Comp. Skin Bearing
Thickness From To Unit Weight Cohesion Angle Friction Friction Capacity SPT'N'
Layer (ft) (ft) (ft) (pcf) (psf) (deg) (ksf) (ksf) (ksf) Counts
3 0 3 110 0 0 0
1.3 3 4.3 110 30 0.2 0.2
4.7 4.3 9 50 30 0.2 0.2
3 9 12 50 29 0.3 0.3
11 12 23 50 28 0.1 0.1
1.5 23 24.5 50 30 0.4 0.4

Analysis Results
Concrete/Steel Check
Soil Lateral Capacity Mu (from soil analysis) 2489.43 k-ft
Depth to Zero Shear: 5.06 ft rJiMn 3300.52 k-ft
Max Moment, Mu: 2489.43 k-ft RATING: 75.4%
Soil Safety Factor: 1.85
Safety Factor Req'd: 1.33
RATING: 71.7% rho provided 0.61
rho required 0.33 OK
Soil Axial Capacity
Skin Friction (k): 53.72 kips Rebar Spacing 10.63
End Bearing (k): 148.44 kips Spacing required 22.56 OK
Comp. Capacity (k), 4>Cn: 202.16 kips
Comp. (k), Cu: 25.00 kips
RATING: 12.4% Dev. Length required 19.11
Dev. Length provided 61.78 OK

Overall Foundation Rating: 75.4%

Page 1 of 1