AIR TO WATER HEAT PUMPS DOMESTIC

What is an air to water heat pump? 12 kW (heating) single package unit Advantages
A device which extracts energy from the will be about 1500 1200 750 mm. Relatively low capital cost (higher than
air and uses it to heat water. Heat pump efficiency usually given gas condensing boiler, lower than
as the Coefficient of Performance ground source heat pump).
How does it work? (CoP)* at a specific operating condition Low running costs.
An air to water heat pump absorbs low (the Standard rating condition is
temperature energy from the air (usually A7W35, i.e. input air at 7C, output Easy to install.
outside air) raises it to a higher, more water at 35C). High efficiency.
useful temperature using a refrigerant The operating range of the heat pump Low energy consumption.
cycle and uses water to deliver the heat. usually the minimum air Low carbon emissions (lower than gas
A heat exchanger transfers the energy temperature is 15C (or 20C if it is condensing boiler).
from the air to a refrigerant with a low fitted with a supplementary direct
boiling point which evaporates and electric heater which boosts the Aspects to consider
circulates in a closed system. The output at low air temperatures). The Possible disturbance from noise
pressure of the refrigerant gas is raised by maximum water temperature is especially from the outdoor fan at
a compressor, which also raises the typically 55C but can be up to 65C. night.
temperature to a useable level. The
The type of heating distribution Possible fouling of the air intake.
refrigerant then condenses in a second
system, including buffer/storage tank
heat exchanger and releases heat to a At low air temperatures water from the
arrangement.
water delivery system. The pressure of air can condense to form ice on the
the refrigerant is then reduced by an Applications outdoor heat exchanger which will
expansion valve, its temperature falls, and need to be defrosted. This is usually
Space heating
it is ready to start the cycle again and done automatically by reversing the
absorb energy from the air. This is the main application. The lower the refrigerant flow. During this short
distribution temperature in the heating process heat output from the heat
Types of air to water heat pump system the higher the efficiency of the pump can be interrupted.
Air to water heat pumps can be: heat pump will be. Heat pumps are With a single phase electricity supply
Single packaged for outdoor therefore best suited for use with low the maximum output is about 12 kW
installation (fully weatherproofed with temperature heating systems such as: (heating), i.e. sufficient to heat a well
insulated water distribution pipes to Underfloor heating (delivery insulated property of over 200 m2.
and from the building). temperature 30-45C). Larger capacity products will require a
Single packaged for indoor installation Fan coils (delivery temperature 3 phase electricity supply.
(requires air intake and outlet, one or 35-55C). When supplementary heating is in use
both of which will be ducted unless Low temperature radiators (delivery the system efficiency will be significantly
the heat pump is installed in a corner). temperature 45-55C). decreased so its use needs to be
Split (a matched pair of units with the carefully controlled. Ensure that the
Domestic hot water heat pump is sized to achieve the
heat pump evaporator mounted
outside and the condenser mounted Heat pumps able to provide supply water majority of the required duty.
indoors the two units are linked in the range 60-65C can provide full
Financial incentives
with pipework containing refrigerant). water heating.
VAT on heat pumps is charged at 5%.
Exhaust air may also be used as the Where the output temperature is lower
source in which case the heat pump is than this the heat pump can provide the Possible grants are available for domestic
usually a single packaged unit mounted in majority of the water heating but installations (Low Carbon Building
the loft. supplementary heating will be needed. Programme, or from Electricity suppliers).
See overleaf diagrams of basic heat Space cooling MCS See Microgeneration Certification
pump system configurations. Scheme product and installer criteria.
Reversible heat pumps can be used with
What you need to know to select fan coils to provide cooling in summer.
a product With underfloor heating partial cooling
can be provided (the minimum water * The Coefficient of Performance is
The building heat loss it is temperature is limited to about 18C to measured as the heating output (kW)
important to size the heat pump limit the risk of condensation). divided by the total power consumed by
accurately. Heat pumps can be sized
Air to water heat pumps are suitable the system including fans, pumps and
to meet all or part of the heating load.
for both new build and retrofit controls (kW). The European Standard for
Heat pump dimensions and location testing and rating heat pump
requirements the physical size will The ideal site:
performance is EN 14511.
vary depending on the output and Is new build (easy to use low
type but will be larger than a gas boiler temperature heating system).
of the same capacity. Typically a Has no access to gas (relatively high
fuel prices).
AIR TO WATER
HEAT PUMPS
DOMESTIC
Types of air to water heat pump
Air to Water
(Repeated from front of leaflet) Single Packaged System
Air to water heat pumps can be:
Single packaged for outdoor
installation (fully weatherproofed with
insulated water distribution pipes to DHW
and from the building). Cylinder
Single packaged for indoor installation
(requires air intake and outlet, one or
both of which will be ducted unless Distribution System
the heat pump is installed in a corner).
Split (a matched pair of units with the M
heat pump evaporator mounted Heat Pump
outside and the condenser mounted
indoors the two units are linked
with pipework containing refrigerant). UF
Exhaust air may also be used as the RAD
Note: Heat Pump may
source in which case the heat pump is be mounted inside but
FC
usually a single packaged unit mounted in return and supply
the loft. airflows will need to be
ducted to the outside.
Diagrams and notes
The diagrams are for illustrative purposes Definitions
UF = Underfloor heating 30-45C
only. Refer to supplier for comprehensive RAD = Low temperature radiators 45-55C
installation details. FC = Fan coils 35-55C
The Heat Pumps shown represent
equipment that supplies warm water for
space heating or DHW on a priority basis.
Heat Pumps that can supply warm water
for space heating and DHW
Air to Water
simultaneously will have two separate Split System
heat pump circuits.
Domestic hot water must be regularly
heated to at least 60C to eliminate any
risk of legionella. This may be achieved by DHW
the heat pump itself or by auxiliary Cylinder
(electric) heating as dictated by the
individual machine specification.
HPA members list and products Distribution System
Heat Pump
For information on heat pump products M
Outdoor
available, please go to our website where
Unit
there is an up-to-date list of members
contact details.
Heat Pump UF
Indoor
RAD
Unit FC

Ne
ww w a FETA Association

w. HP Heat Pump Association


he
atp A 2 Waltham Court, Milley Lane,

um We
Hare Hatch, Reading, Berks RG10 9TH
Telephone: 0118 940 3416
. b
ps
org sit Facsimile: 0118 940 6258
E-mail: info@feta.co.uk
.uk e

You might also like