Sanken Lanka (Pvt) Ltd.

Record
Design Office

subject FISHERIES job


CALCULATION SHEET SEYCHELLES job no
computed CA date
checked PP page

REF CALCULATION

M20 bolts
Torque : 150 Nm
Torque coefficient : 0.15
Bolt diameter : 20 mm

T= KDP
T :- Torque (lb in)
K :- Torque coefficient
D :- Bolt diameter (in)
P :- Bolt tension (lb)

Hence, P = 11160.7143 lb
50.73 kN

Min Tensile load = 225 kN Gr. 8.8

Hence satisfactory

M16 bolts
Torque : 100 Nm
Torque coefficient : 0.15
Bolt diameter : 16 mm

T= KDP
T :- Torque (lb in)
K :- Torque coefficient
D :- Bolt diameter (in)
P :- Bolt tension (lb)

Hence, P = 9300.59524 lb
42.28 kN

Min Tensile load = 144 kN Gr. 8.8

Hence satisfactory
Record No:SL/DD/CLS/11
Revision No.00

SOSE4
45
7/23/2009
1 of
1 pages

OUTPUT