You are on page 1of 147

ZXR10 8900E

Series Core Switch


Hardware Description

Version: 3.01.01

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright 2013 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

R1.0 2013-06-24 First edition

Serial Number: SJ-20121213142710-003

Publishing Date: 2013-06-24 (R1.0)

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Contents
About This Manual ......................................................................................... I
Chapter 1 Safety Instructions.................................................................... 1-1
Chapter 2 Cabinet....................................................................................... 2-1
Chapter 3 System Overview ...................................................................... 3-1
3.1 Features ............................................................................................................ 3-1
3.2 Front Panel ........................................................................................................ 3-2
3.3 Slot Layout ........................................................................................................ 3-6
3.4 Architecture ....................................................................................................... 3-9
3.5 Technical Specifications.....................................................................................3-11
3.6 Reliability ......................................................................................................... 3-13

Chapter 4 Power Supply Modules............................................................. 4-1


4.1 ZXR10 8912E/8908E/8905E Power Supply Module.............................................. 4-1
4.2 ZXR10 8902E Power Supply Module ................................................................... 4-3

Chapter 5 Heat Dissipation System .......................................................... 5-1


5.1 Overview ........................................................................................................... 5-1
5.2 Fan Subrack ...................................................................................................... 5-3
5.3 Air Filter............................................................................................................. 5-3

Chapter 6 Cards.......................................................................................... 6-1


6.1 Card Classification ............................................................................................. 6-1
6.2 MCS Card.......................................................................................................... 6-2
6.2.1 8912EMCS1D.......................................................................................... 6-2
6.2.2 8908EMCS1D.......................................................................................... 6-7
6.2.3 8905EMCS1D........................................................................................ 6-12
6.2.4 8902EMCS1D........................................................................................ 6-16
6.2.5 8902EMCS1A ........................................................................................ 6-21
6.2.6 8905EMCS1A ........................................................................................ 6-25
6.2.7 8908EMCS1A ........................................................................................ 6-29
6.2.8 8912EMCS1A ........................................................................................ 6-34
6.3 Line Interface Cards ......................................................................................... 6-37
6.3.1 H2GF48D .............................................................................................. 6-37
6.3.2 H2GF24D .............................................................................................. 6-43
6.3.3 H2GT48D .............................................................................................. 6-49

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


6.3.4 H2XF8D ................................................................................................ 6-51
6.3.5 S1XF12A ............................................................................................... 6-54
6.3.6 S2LQ6L2A............................................................................................. 6-56
6.3.7 S2XF48A ............................................................................................... 6-59
6.3.8 S1GF48A .............................................................................................. 6-62
6.3.9 S1GT48A .............................................................................................. 6-69
6.3.10 S2XF4A ............................................................................................... 6-71
6.3.11 S1GT24A ............................................................................................. 6-74
6.3.12 S1GF24A............................................................................................. 6-76
6.4 Instructions on Card Usage............................................................................... 6-81

Chapter 7 Optical Modules ........................................................................ 7-1


Appendix A Indicator Reference Table.................................................... A-1
A.1 8912EMCS1D Indicators .................................................................................... A-1
A.2 8908EMCS1D Indicators .................................................................................... A-2
A.3 8905EMCS1D Indicators .................................................................................... A-3
A.4 8902EMCS1D Indicators .................................................................................... A-4
A.5 H2GF48D Indicators .......................................................................................... A-5
A.6 H2GF24D Indicators .......................................................................................... A-6
A.7 H2GT48D Indicators .......................................................................................... A-6
A.8 H2XF8D Indicators............................................................................................. A-6
A.9 S1XF12A Indicators ........................................................................................... A-6
A.10 S2LQ6L2A Indicators ....................................................................................... A-7
A.11 S2XF48A Indicators.......................................................................................... A-7
A.12 S1GT48A Indicators ......................................................................................... A-7
A.13 S1GT24A Indicators ......................................................................................... A-8
A.14 S1GF48A Indicators ......................................................................................... A-8
A.15 S1GF24A Indicators ......................................................................................... A-8
A.16 Fan Module Indicators ...................................................................................... A-9

Appendix B Card Reference Table........................................................... B-1


B.1 Card List ........................................................................................................... B-1
B.2 Technical Specifications of the Cards .................................................................. B-2

Figures............................................................................................................. I
Tables ............................................................................................................ III
Glossary .......................................................................................................VII

II

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


About This Manual
Purpose
This manual describes the hardware of the ZXR10 8900E (V3.01.01) switch.

Intended Audience
This manual is intended for:
l Network planning engineers
l Equipment installation engineers
l Debugging engineers
l Maintenance engineers

What Is in This Manual


This manual contains the following chapters:

Chapter Summary

1, Safety Instructions Describes safety instructions for the ZXR10 8900E series
switches.

2, Cabinet Describes the overview, structure, and technical parameters of


the cabinet used for the ZXR10 8900E.

3, System Overview Describes the overview, functions, structure, technical


parameters, and reliability of the ZXR10 8900E.

4, Power Supply Modules Describes power supply modules of the ZXR10 8900E.

5, Heat Dissipation System Describes the heat dissipation system of the ZXR10 8900E.

6, Cards Describes the main control and switching modules and line
interface cards of the ZXR10 8900E, and instructions on card
usage.

7, Optical Modules Describes optical modules of the ZXR10 8900E.

Conventions
This manual uses the following typographical conventions:

Typeface Meaning

Italics Variables in commands. It may also refer to other related manuals and documents.

Bold Menus, menu options, function names, input fields, option button names, check boxes,
drop-down lists, dialog box names, window names, parameters, and commands.

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Typeface Meaning

Caution: indicates a potentially hazardous situation. Failure to comply can result in


moderate injury, equipment damage, or interruption of minor services.

II

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 1
Safety Instructions
Only duly trained and qualified personnel can install, operate and maintain the equipment.
During the equipment installation, operation and maintenance, users must comply with
local safety specifications and related instructions. Failure to comply may result in personal
injury or damage to the equipment. The safety instructions mentioned in this manual are
only a supplement to local safety specifications.
Running the debug command improperly may affect the equipment performance, so it is
not recommended to run the debug command when the equipment operates properly. The
debug all command opens all debug processes, so it should not be used on the equipment
that is operating services.
ZTE Corporation bears no responsibility for consequences resulting from violation
of the general specifications for safety operations or the safety rules for designing,
manufacturing, and using the equipment.

1-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

1-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 2
Cabinet
The ZXR10 8900E system uses a B608020 cabinet manufactured by ZTE. The cabinet
complies with the international standard IEC 60297-2, and the maximum internal space is
47U.

Overview
For the overview of the B608020 cabinet, see Figure 2-1.

2-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 2-1 B6080-20 Cabinet

Structure
For the structure of the B6080-20 cabinet, see Figure 2-2.

2-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 2 Cabinet

Figure 2-2 Structure of the B6080-20 Cabinet

1. Front door 6. Connecting plate 11. Air filter


2. Top panel 7. Top side panel 12. Leg
3. Rack 8. Supporting plate 13. Decoration plate
4. Top cable trough 9. Side door
5. Connection board 10. Side decoration plate

Technical Parameters
For the technical parameters of the B608020 cabinet, refer to Table 2-1.

Table 2-1 Technical Parameters of the B608020 Cabinet

Parameter Specification

2000 mm 600 mm 800 mm (H W D)


Dimensions (If the side door and top decoration plate is included, the dimensions are
2200 mm 648 mm 800 mm.)

2-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Parameter Specification

Internal space The maximum internal space is 47 U.

Maximum weight The net weight of the cabinet is 110 kg. In full configuration, the total weight is
not more than 350 kg.

Cable routing mode Top routing and bottom routing are supported.

2-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3
System Overview
Table of Contents
Features.....................................................................................................................3-1
Front Panel ................................................................................................................3-2
Slot Layout .................................................................................................................3-6
Architecture................................................................................................................3-9
Technical Specifications ...........................................................................................3-11
Reliability..................................................................................................................3-13

3.1 Features
The ZXR10 8900E series switches of ZTE Corporation are applicable to the backbone
layer or convergence layer of Metropolitan Area Network (MAN). They can serve as
backbone/convergence layer switches for corporation and campus networks.
The ZXR10 8900E series switches can provide gigabit, 10-gigabit, 40-gigabit, and
100-gigabit Ethernet interfaces, and support Synchronous Ethernet, the IEEE 1588v2
precision time protocol, and GPS time synchronization. All the ports support full
wire-speed forwarding of Layer 2 and Layer 3, which means that they satisfy the
increasing requirements for bandwidth. The ZXR10 8900E series switches support
multiple unicast and multicast protocols.
Services carried by data network increase rapidly with the network development. It
requires higher Quality of Service (QoS) and better security for network equipment. The
ZXR10 8900E series switches provide policies and resources of QoS and Access Control
List (ACL), which assures the system security.

The ZXR10 8900E series switches provide the hot-swapping function for power supply
modules and Main Control and Switching (MCS) modules, which means that they are
applicable to large-capacity networks with high reliability.

The ZXR10 8900E series switches have the following features:


l Large system capacity
l Carrier-class reliability
l Capability to bearing all services
l Full wire-speed forwarding and filtering capability
l Support of multiple network protocols
l Open architecture that supports high upgrade performance
l Energy saving and environment friendly
l Intelligent unified operation and maintenance system

3-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

3.2 Front Panel


This section describes the front panel of each type of ZXR10 8900E switch.
For the front panel of the ZXR10 8912E switch, see Figure 3-1.

3-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

Figure 3-1 ZXR10 8912E Front Panel

For the front panel of the ZXR10 8908E switch, see Figure 3-2.

3-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 3-2 ZXR10 8908E Front Panel

For the front panel of the ZXR10 8905E switch, see Figure 3-3.

3-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

Figure 3-3 ZXR10 8905E Front Panel

For the front panel of the ZXR10 8902E (DC) switch, see Figure 3-4.

Figure 3-4 ZXR10 8902E (DC) Front Panel

For the front panel of the ZXR10 8902E (AC) switch, see Figure 3-5.

3-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 3-5 ZXR10 8902E (AC) Front Panel

3.3 Slot Layout


The ZXR10 8900E switch consists of a chassis, power subracks, cards, a fan subrack,
and a back panel. It uses a standard 19 chassis that can be installed independently or in
a standard 19 cabinet.
l The ZXR10 8912E has 14 slots, two for MCS modules and 12 for line interface cards.
l The ZXR10 8908E has 10 slots, two for MCS modules and eight for line interface
cards.
l The ZXR10 8905E has seven slots, two for MCS modules and five for line interface
cards.
l The ZXR10 8902E has four slots, two for MCS modules and two for line interface
cards.
For the ZXR10 8912E slot layout, see Figure 3-6.

3-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

Figure 3-6 ZXR10 8912E Slot Layout

For the ZXR10 8908E slot layout, see Figure 3-7.

3-7

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 3-7 ZXR10 8908E Slot Layout

For the ZXR10 8905E slot layout, see Figure 3-8.

Figure 3-8 ZXR10 8905E Slot Layout

For the ZXR10 8902E slot layout, see Figure 3-9.

3-8

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

Figure 3-9 ZXR10 8902E Slot Layout

3.4 Architecture
The ZXR10 8900E uses different racks to implement the functions of switching plane,
management plane, and monitoring plane, which operate together to serve as a switch.
MCS modules and line interface cards are installed on a back panel with fast serial
buses. An MCS module contains a switching matrix, a CPU module, and a memory,
and operates in 1:1 redundancy mode. The switching matrix ensures the large switching
capacity required during wire-speed operation of the switch. The high-performance CPU
module ensures fast protocol processing, and the memory provides sufficient storage
space required due to large tables. Each line interface card provides wire-speed packet
processing through its ASIC and provides gigabit and 10-gigabit interfaces.
For the hardware architecture of the ZXR10 8912E/8908E/8905E switch, see Figure 3-10.

3-9

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 3-10 ZXR10 8912E/8908E/8905E Hardware Architecture

For the hardware architecture of the ZXR10 8902E switch, see Figure 3-11.

Figure 3-11 ZXR10 8902E Hardware Architecture

The ZXR10 8900E consists of the following components:


l MCS module
An MCS module contains a CPU module, a large memory, an inter-card switching
module, a monitoring module, and a clock module. The MCS module operates in
1:1 redundancy mode. Each MCS module of the ZXR10 8912E/8908E/8905E switch
also contains a large-capacity switching matrix (with independent planes) to ensure
the switching and capacity expansion capabilities. The MCS modules of the ZXR10
8902E switch have no switching matrix, and the line interface cards are connected

3-10

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

through a fast-speed back panel. Two MCS modules can provide a maximum
switching capacity of 2048 Gbps.
l Line interface cards
Line interface cards process packets and send the packets to a specific port of the
destination line interface card based on the processing result. Each line interface
card has its own forwarding table, and forwarding decisions are determined locally
to ensure the wire-speed switching capability. Some line interface cards support
the clock synchronization and intelligent monitoring functions. The ZXR10 8900E
provides the following line interface cards:

Gigabit Ethernet interface card


10-gigabit Ethernet interface card
40-gigabit Ethernet interface card

l Power supply module


The power supply modules of the ZXR10 8900E can be monitored by the MCS module
through teleindication. The MCS module intelligently monitors the temperature and
operational status (such as overvoltage/undervoltage, power failure alarms, and
current limiting) of the power supply modules with the RS485 interface.
l Fan subrack
The ZXR10 8900E uses an intelligent fan subrack, which can regulate the rotation
speed of each fan based on the temperature of the corresponding card slot. The fan
subrack can also send alarms for fan failure and underspeed.

3.5 Technical Specifications


Configuration
For the ZXR10 8900E configuration, refer to Table 3-1.

Table 3-1 ZXR10 8900E Configuration

Item Specification

CPU Single core, CPU speed: 800 MHz

Flash Maximum capacity: 256 MB

SD card Maximum capacity: 32 GB

BOOT Flash 16 MB

DDR3 SDRAM Maximum capacity: 4 GB

Physical Parameters
For physical parameters of the ZXR10 8900E, refer to Table 3-2.

3-11

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 3-2 ZXR10 8900E Physical Parameters

Parameter ZXR10 8912E ZXR10 8908E ZXR10 8905E ZXR10 8902E

Dimensions 753 mm 442 575 mm 442 442 mm 442 175 mm 442


(height width mm 446 mm mm 446 mm mm 446 mm mm 420 mm
depth)

Weight (single 35.8 kg 26.3 kg 24.3 kg 14 kg


cabinet)

Weight (full 89.7 kg 64.9 kg 51.2 kg 24 kg


configuration)

Power supply AC: 100V to 240V, 60 Hz to 50 Hz


DC: -57V to -40V

Power 2718 W 2084 W 1235 W 300 W


consumption (full
configuration)

Reliability EMC:
l FCC Part 15 (CFR 47) Class A
l EN 55022 Class A
l EN 300 386 V1.3.1
l EN55024
l ICES-003 Class A
Safety:
l UL 60950 3rd Edition
l CSA C22.2 No. 60950 3rd Edition
l IEC 6095
l EN 60950
l EN60825-1+A1 and EN60825-2

Lightening 4 KV
protection

Operational For long term: 5 to 45


ambient For short term: -5 to 50
temperature

Storage ambient -40 to +70


temperature

Relative humidity 5% to 95% (non-condensing)

GE ports 576 384 240 96

10-GE ports 576 384 240 96

40-GE ports 96 64 40 16

3-12

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 3 System Overview

3.6 Reliability
For ZXR10 8900E reliability parameters, refer to Table 3-3.

Table 3-3 ZXR10 8900E Reliability Parameters

Parameter Specification

MTBF >200000 hours.

MTTR <30 minutes.

Reliability 99.999%.

Hot swapping All the cards are hot swappable.

MCS module 1:1 redundancy.


redundancy

Power supply module ZXR10 8912E: 2+1 redundancy (AC)


redundancy Others: 1+1 redundancy

3-13

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

3-14

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 4
Power Supply Modules
Table of Contents
ZXR10 8912E/8908E/8905E Power Supply Module ...................................................4-1
ZXR10 8902E Power Supply Module..........................................................................4-3

4.1 ZXR10 8912E/8908E/8905E Power Supply Module


Introduction
The power supply modules of the ZXR10 8912E/8908E/8905E switch are hot standby.
Either -48 V DC or 220 V AC power supply modules can be used. The DC power supply
modules operate in 1+1 redundancy mode and the AC power supply modules operate in
1+1 or 2+1 redundancy mode.
For the front panel of the ZXR10 8912E/8908E/8905E power supply module, see Figure
4-1.

Figure 4-1 Front Panel of the ZXR10 8912E/8908E/8905E Power Supply Module

DC Power Supply Module


A DC power supply module of the ZXR10 8912E/8908E/8905E switch provides -48 V DC
output and has the following functions:
l Overcurrent protection
l Short circuit protection
l Alarms for overtemperature, overpressure, fan failure, and current limiting
l Voltage detection and reporting
l Current detection and reporting
l Temperature detection and reporting
Two DC power supply modules are used for 1+1 redundancy. One power supply module
can fully meet the power requirement of the entire chassis. When both modules operate, if
one module fails, the other module is not affected and still can supply power to the system.

4-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

For the rear panel of the DC power supply module of the ZXR10 8912E/8908E/8905E
switch, see Figure 4-2.

Figure 4-2 Rear Panel of the ZXR10 8912E/8908E/8905E DC Power Supply Module

1. Handle 5. Negative input terminal 9. Grounding screw hole


2. PWR3 power supply switch of the -48V PWR1 power
3. Negative input terminal supply
of the -48V PWR3 power 6. Positive input terminal of
supply the -48V PWR1 power
4. Positive input terminal of supply
the -48V PWR3 power 7. Fastening screw
supply 8. PWR1 power supply switch

For technical specifications of the ZXR10 8912E/8908E/8905E DC power supply module,


refer to Table 4-1.

Table 4-1 Technical Specifications of the ZXR10 8912E/8908E/8905E DC Power Supply


Module

Parameter Specification

Rated input voltage -48 V DC

Input voltage range -57V DC to -40 V DC

Maximum output power 2700 W

AC Power Supply Module


An AC power supply module of the ZXR10 8912E/8908E/8905E switch provides -53.5 V
DC output and has the following functions:

l Output overcurrent protection


l Output overvoltage protection
l Output undervoltage protection
l Over temperature protection
l Short circuit protection
l Input overvoltage protection
l Input undervoltage protection
l Alarms for overtemperature, overvoltage, fan failure, and current limiting
l Voltage detection and reporting
l Current detection and reporting
l Temperature detection and reporting

4-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 4 Power Supply Modules

The ZXR10 8912E AC power supply modules operate in 2+1 redundancy mode and the
ZXR10 8908E/8905E AC power supply modules operate in 1+1 redundancy mode. A
switch can have two or three AC power supply modules as required.
For the rear panel of the AC power supply module of the ZXR10 8912E/8908E/8905E
switch, see Figure 4-3.

Figure 4-3 Rear Panel of the ZXR10 8912E/8908E/8905E AC Power Supply Module

For technical specifications of the ZXR10 8912E/8908E/8905E AC power supply module,


refer to Table 4-2.

Table 4-2 Technical Specifications of the ZXR10 8912E/8908E/8905E AC Power Supply


Module

Parameter Specification

Rated input voltage 100 V AC to 240 V AC

Input frequency 50 Hz to 60 Hz

Rated output power 2140 W

Rated output voltage -53.5 V DC

4.2 ZXR10 8902E Power Supply Module


Introduction
The power supply modules of the ZXR10 8902E switch are hot standby. Either -48 V DC
or 220 V AC power supply modules can be used.
Both DC and AC power supplies operate in 1+1 redundancy mode.
The switch and input cable of the ZXR10 8902E power supply module are located on the
front of the chassis. The power supply system uses a modular design. Users can select
power supply modules as required.

DC Power Supply Module


A DC power supply module of the ZXR10 8902E switch provides -48 V DC output and has
the following functions:
l Output overcurrent protection
l Short circuit protection
l Alarms for overtemperature, overvoltage, fan failure, and current limiting

4-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

l Voltage detection and reporting


l Current detection and reporting
l Temperature detection and reporting
The ZXR10 8902E DC power supply modules operate in 1+1 redundancy mode. A switch
can have 12 DC power supply modules as required.
For the front panel of the ZXR10 8902E DC power supply module, see Figure 4-4.

Figure 4-4 Front Panel of the ZXR10 8902E DC Power Supply Module

For technical specifications of the ZXR10 8902E DC power supply module, refer to Table
4-3.

Table 4-3 Technical Specifications of the ZXR10 8902E DC Power Supply Module

Parameter Specification

Rated input voltage -48 V DC

Input voltage range -57 V DC to -40 V DC

Rated output power 300 W

AC Power Supply Module


An AC power supply module of the ZXR10 8902E switch provides -53.5 V DC output and
has the following functions:
l Output overcurrent protection
l Output overvoltage protection
l Output undervoltage protection
l Overtemperature protection
l Short circuit protection
l Input overvoltage protection
l Input undervoltage protection
l Alarms for overtemperature, overvoltage, fan failure, and current limiting
l Voltage detection and reporting
l Current detection and reporting
l Temperature detection and reporting

The ZXR10 8902E AC power supply modules operate in 1+1 redundancy mode. A switch
can have 12 AC power supply modules as required. For the front panel of the ZXR10
8902E AC power supply module, refer to Figure 4-5.

4-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 4 Power Supply Modules

Figure 4-5 Front Panel of the ZXR10 8902E AC Power Supply Module

For technical specifications of the ZXR10 8902E AC power supply module, refer to Table
4-4.

Table 4-4 Technical Specifications of the ZXR10 8902E AC Power Supply Module

Parameter Specification

Rated input voltage 100 V AC to 240 V AC

Input frequency 50 Hz to 60 Hz

Rated output power 318 W

Rated output voltage -53.5 V DC

4-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

4-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 5
Heat Dissipation System
Table of Contents
Overview ....................................................................................................................5-1
Fan Subrack...............................................................................................................5-3
Air Filter .....................................................................................................................5-3

5.1 Overview
The ZXR10 8900E switch fan subrack takes in air at the chassis right side (in face of the
chassis) and dissipates heat by forcing air out from the chassis left side. Aluminum/copper
is used as heat-sink material. An air filter is installed at the air inlet to filter the inducted air,
which can be removed for easy maintenance. The ZXR10 8900E switch supports speed
control of each fan for the corresponding slot.
The ZXR10 8900E series switches have the following types of fan subracks:
l ZXR10 8912E fan subrack
l ZXR10 8908E fan subrack
l ZXR10 8908E fan subrack
l ZXR10 8902E fan subrack
For the overview of the ZXR10 8912E fan subrack, see Figure 5-1.

Figure 5-1 ZXR10 8912E Fan Subrack

For the overview of the ZXR10 8908E fan subrack, see Figure 5-2.

5-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 5-2 ZXR10 8908E Fan Subrack

For the overview of the ZXR10 8905E fan subrack, see Figure 5-3.

Figure 5-3 ZXR10 8905E Fan Subrack

For the overview of the ZXR10 8902E fan subrack, see Figure 5-4.

Figure 5-4 ZXR10 8902E Fan Subrack

The ZXR10 8912E/8908E/8905E fan subrack has two indicators. For a description of
indicators, refer to Table 5-1.

Table 5-1 ZXR10 8912E/8908E/8905E Indicator Descriptions

Indicator Description

RUN (green) Not lit: The fan subrack operates improperly.


Lit: The fan subrack operates properly.

ALM (red) Not lit: The fan subrack operates properly.


Lit: The fan subrack operates improperly.

The ZXR10 8902E fan subrack has no indicator. The fan operation is indicated by the FAN
indicator on the active MCS module.

5-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 5 Heat Dissipation System

5.2 Fan Subrack


The ZXR10 8900E series switches have four types of fan subracks. For technical
specifications of the fan subracks, refer to Table 5-2.

Table 5-2 Technical Specifications of Fan Subracks

Type Dimensions (width Number of Fans Maximum Air Flow


height depth) (Unit: Rate (Unit: CFM)
mm)

ZXR10 8902E 30.1171.8379.5 6 326.7

ZXR10 8905E 36.2284.2372.5 9 675

ZXR10 8908E 36.1406.7372.4 12 900

ZXR10 8912E 37.7571.8374.4 18 1350

The ZXR10 8900E series switches can automatically regulate the fan speed according
to temperatures of MCS modules and line interface cards. Or users can regulate the fan
speed manually.

5.3 Air Filter


There is a vertical air filter at the air inlet of the ZXR10 8900E chassis.
For how to install or remove an air filter of the ZXR10 8902E switch, see Figure 5-5.

Figure 5-5 ZXR10 8902E Air Filter

For how to install or remove an air filter of the ZXR10 8905E switch, see Figure 5-6.

5-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 5-6 ZXR10 8905E Air Filter

For how to install or remove an air filter of the ZXR10 8908E switch, see Figure 5-7.

Figure 5-7 ZXR10 8908E Air Filter

For how to install or remove an air filter of the ZXR10 8912E switch, see Figure 5-8.

5-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 5 Heat Dissipation System

Figure 5-8 ZXR10 8912E Air Filter

5-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

5-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6
Cards
Table of Contents
Card Classification .....................................................................................................6-1
MCS Card ..................................................................................................................6-2
Line Interface Cards .................................................................................................6-37
Instructions on Card Usage ......................................................................................6-81

6.1 Card Classification


For the cards that the ZXR10 8900E supports, refer to Table 6-1.

Table 6-1 Cards Supported by the ZXR10 8900E

Name Type Description

8912EMCS1D Main control and switching card ZXR10 8912E MCS with a clock
module

8908EMCS1D Main control and switching card ZXR10 8908E MCS with a clock
module

8905EMCS1D Main control and switching card ZXR10 8905E MCS with a clock
module

8902EMCS1D Main control and switching card ZXR10 8902E MCS with a clock
module

8902EMCS1A Main control and switching card ZXR10 8902E MCS without
clock module

8905EMCS1A Main control and switching card ZXR10 8905E MCS without
clock module

8908EMCS1A Main control and switching card ZXR10 8908E MCS without
clock module

8912EMCS1A Main control and switching card ZXR10 8912E MCS without
clock module

H2GF48D Line interface card 48-port GE optical interface


card with a clock module

H2GF24D Line interface card 24-port GE optical interface


card with a clock module

H2GT48D Line interface card 48-port GE electrical interface


card with a clock module

6-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Name Type Description

H2XF8D Line interface card 8-port 10-GE optical interface


card with a clock module

S1XF12A Line interface card 12-port 10-GE optical interface


card with a clock module, which
has no expansion slot

S2LQ6L2A Line interface card 8-port 40-GE optical interface


card with a clock module

S2XF48A Line interface card 48-port 10-GE optical interface


card with a clock module

S1GF48A Line interface card 48-port GE optical interface


card with a clock module

S1GT48A Line interface card 48-port GE electrical interface


card with a clock module

S2XF4A Line interface card 4-port 10-GE optical interface


card with a clock module

6.2 MCS Card


As the core of the ZXR10 8900E, the Main Control and Switching (MCS) card implements
the control and switching functions. Its flash memory stores the system software and
configuration information.

6.2.1 8912EMCS1D
Function
The 8912EMCS1D module is an enhanced MCS module of the ZXR10 8912E switch,
and provides the active/standby switchover function based on 1+1 redundancy. The
8912EMCS1D module supports Synchronous Ethernet, IEEE 1588v2, and GPS time
synchronization.
The 8912EMCS1D module provides the following functions:
l Large switching capacity
A single card provides a maximum switching capacity of 1024 Gbps.
l Gigabit out-of-band communication
It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8912EMCS1D module provides the online upgrade function through
simulating the JTAG interface.

6-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

l JTAG test
The 8912EMCS1D module connects to main chips of line interface cards through a
daisy chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the module to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.

l Synchronous Ethernet & IEEE 1588v2 & GPS time synchronization


l Time synchronization through GPS or BITS.

Panel
For the 8912EMCS1D front panel, see Figure 6-1.

Figure 6-1 8912EMCS1D Front Panel

Interfaces
The 8912EMCS1D module provides the following interfaces:
l Console port

The console port connects to a back-end management terminal, which performs


operations and maintenance of the ZXR10 8912E through the HyperTerminal. The
console port uses an RJ45 connector. It connects to the COM port of the back-end
management terminal through a serial cable. One end of the serial cable is connected
to the RJ45 connector of the ZXR10 8912E, and the other end is connected to
the DB9 female connector of the back-end management terminal. For the wiring
sequence of the console cable, refer to Table 6-2.

Table 6-2 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port

6-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

The IPMC port connects to a back-end management terminal, which performs


operations and maintenance of the internal intelligent platform management system
of the ZXR10 8912E through the HyperTerminal. The IPMC port uses an RJ45
socket. It connects to the COM port of the back-end management terminal through a
serial cable. One end of the serial cable is connected to the RJ45 connector of the
ZXR10 8912E, and the other end is connected to the DB9 female connector of the
back-end management terminal. For the wiring sequence of the IPMC cable, refer to
Table 6-3.

Table 6-3 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port


The 8912EMCS1D module has a 10/100Base-TX Ethernet port (MGT) for connecting
to a back-end management system. It uses an RJ45 connector and an Category 5
Unshielded Twisted Pair (UTP) cable with the maximum transmission distance of 100
m.
l SD card slot
An SD card can be inserted to store system software and configuration information.
An SD card up to 32 GB is supported.

Caution!
When information stored on the SD card is being read, the ACT indicator flashes. It's
not allowed to remove the SD card when it is being read to prevent data loss.

l PPS&TOD OUT

This port is used for GPS Pulse Per Second (PPS) and Time of Date (TOD) output. It
uses an RJ 45 connector and provides RS422 level output. For the wiring sequence
of the PPS&TOD OUT cable, refer to Table 6-4.

Table 6-4 Wiring Sequence of the PPS&TOD OUT Cable

RJ45 Signal RJ45 Signal

3 1PPS_OUT_N 6 1PPS_OUT_P

7 TOD_OUT_N 8 TOD_OUT_P

6-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

l PPS&TOD IN
This port is used for GPS PPS and TOD input. It uses an RJ45 connector and provides
RS422 level input. For the wiring sequence of the PPS&TOD IN cable, refer to Table
6-5.

Table 6-5 Wiring Sequence of the PPS&TOD IN Cable

RJ45 Signal RJ45 Signal

3 1PPS_IN_N 6 1PPS_IN_P

7 TOD_IN_N 8 TOD_IN_P

l BITS IN
This port is used for BITS signal input. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.
l BITS OUT
This port is used for BITS signal output. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.

Indicators
There are 37 indicators on the front panel of the 8912EMCS1D module. For a description
of these indicators, refer to Table 6-6.

Table 6-6 8912EMCS1D Indicator Descriptions

Indicator Description

112 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

6-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

Buttons
There are three buttons on the front panel of the 8912EMCS1D module. For a description
of these buttons, refer to Table 6-7.

Table 6-7 Button Descriptions

Button Description

RST Reset button: resets the module.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

Technical Parameters
For technical parameters of the 8912EMCS1D module, refer to Table 6-8.

Table 6-8 8912EMCS1D Technical Parameters

Parameter Description

Silk screen name 8912EMCS1D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 56.5 W


Full-load power consumption: about 84.8 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version FLASH: 512 MB


Boot FLASH: 16 MB

Memory Slot One SODIMM slot

Maximum capacity 4 GB

6-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Parameter Description

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (upper)


management port

RS232 Console Two-layer RJ45 port (lower)

SD card slot One

PPS&TOD OUT One

PPS&TOD IN One

BITS IN One

BITS OUT One

6.2.2 8908EMCS1D
Function
The 8908EMCS1D module is an enhanced MCS module of the ZXR10 8902E switch,
and provides the active/standby switchover function based on 1+1 redundancy. The
8908EMCS1D module supports Synchronous Ethernet, IEEE 1588v2, and GPS time
synchronization.

The 8908EMCS1D module provides the following functions:


l Large switching capacity
A single card provides a maximum switching capacity of 1024 Gbps.
l Gigabit out-of-band communication
It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8908EMCS1D module provides the online upgrade function through
simulating the JTAG interface.

l JTAG test
The 8908EMCS1D module connects to main chips of line interface cards through a
daisy chain to conduct the JTAG test.

l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the module to implement real-time monitoring through the IIC bus.

l IPMC management and control unit

6-7

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2 & GPS time synchronization
l Time synchronization through GPS or BITS.

Panel
For the 8908EMCS1D front panel, see Figure 6-2.

Figure 6-2 8908EMCS1D Front Panel

Interfaces
The 8908EMCS1D module provides the following interfaces:
l Console port
The console port connects to a back-end management terminal, which performs
operations and maintenance of the ZXR10 8908E through the HyperTerminal. The
console port uses an RJ45 socket. It connects to the COM port of the back-end
management terminal through a serial cable. One end of the serial cable is connected
to the RJ45 connector of the ZXR10 8908E, and the other end is connected to
the DB9 female connector of the back-end management terminal. For the wiring
sequence of the console cable, refer to Table 6-9.

Table 6-9 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port
The IPMC port connects to a back-end management terminal, which performs
operations and maintenance of the internal intelligent platform management system
of the ZXR10 8908E through the HyperTerminal. The IPMC port uses an RJ45
socket. It connects to the COM port of the back-end management terminal through a
serial cable. One end of the serial cable is connected to the RJ45 connector of the
ZXR10 8908E, and the other end is connected to the DB9 female connector of the
back-end management terminal. For the wiring sequence of the IPMC cable, refer
to Table 6-10.

6-8

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-10 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port


The 8908EMCS1D module has a 10/100/1000Base-T Ethernet port (MGT) for
connecting to a back-end management system. It uses an RJ45 connector and an
Category 5 UTP cable with the maximum transmission distance of 100 m.
l SD card slot
An SD card can be inserted to store system software and configuration information.
An SD card up to 32 GB is supported.

Caution!
When information stored on the SD card is being read, the ACT indicator flashes. It's
not allowed to remove the SD card when it is being read to prevent data loss.

l PPS&TOD OUT
This port is used for GPS Pulse Per Second (PPS) and Time of Date (TOD) output. It
uses an RJ 45 connector and provides RS422 level output. For the wiring sequence
of the PPS&TOD OUT cable, refer toTable 6-11.
Table 6-11 Wiring Sequence of the PPS&TOD OUT Cable

RJ45 Signal RJ45 Signal

3 1PPS_OUT_N 6 1PPS_OUT_P

7 TOD_OUT_N 8 TOD_OUT_P

l PPS&TOD IN
This port is used for GPS PPS and TOD input. It uses an RJ45 connector and provides
RS422 level input. For the wiring sequence of the PPS&TOD IN cable, refer to Table
6-12.
Table 6-12 Wiring Sequence of the PPS&TOD IN Cable

RJ45 Signal RJ45 Signal

3 1PPS_IN_N 6 1PPS_IN_P

7 TOD_IN_N 8 TOD_IN_P

6-9

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

l BITS IN
This port is used for BITS signal input. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.
l BITS OUT
This port is used for BITS signal output. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.

Indicators
There are 29 indicators on the front panel of the 8908EMCS1D module. For a description
of these indicators, refer to Table 6-13.

Table 6-13 8908EMCS1D Indicator Descriptions

Indicator Description

18 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

6-10

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Buttons
There are three buttons on the front panel of the 8908EMCS1D module. For a description
of these buttons, refer to Table 6-14.

Table 6-14 Button Descriptions

Button Description

RST Reset button: resets the module.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

Technical Parameters
For technical parameters of the 8908EMCS1D module, refer to Table 6-15.

Table 6-15 8908EMCS1D Technical Parameters

Parameter Description

Silk screen name 8908EMCS1D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 56.5 W


Full-load power consumption: about 84.8 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version FLASH: 512 MB


Boot FLASH: 16 MB

Memory Slot One SODIMM slot

Maximum capacity 4 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (upper)


management port

RS232 Console Two-layer RJ45 port (lower)

SD card slot One

PPS&TOD OUT One

PPS&TOD IN One

BITS IN One

BITS OUT One

6-11

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

6.2.3 8905EMCS1D
Function
The 8905EMCS1D module is an enhanced MCS module of the ZXR10 8905E switch,
and provides the active/standby switchover function based on 1+1 redundancy. The
8905EMCS1D module supports Synchronous Ethernet, IEEE 1588v2, and GPS time
synchronization.
The 8905EMCS1D module provides the following functions:
l Large switching capacity
A single card provides a maximum switching capacity of 640 Gbps.
l Gigabit out-of-band communication
It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8905EMCS1D module provides the online upgrade function through
simulating the JTAG interface.
l JTAG test
The 8905EMCS1D module connects to main chips of line interface cards through a
daisy chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the module to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2 & GPS time synchronization
l Time synchronization through GPS or BITS.

Panel
For the 8905EMCS1D front panel, see Figure 6-3.

Figure 6-3 8905EMCS1D Front Panel

Interfaces
The 8905EMCS1D module provides the following interfaces:
l Console port

6-12

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

The console port connects to a back-end management terminal, which performs


operations and maintenance of the ZXR10 8905E through the HyperTerminal. The
console port uses an RJ45 socket. It connects to the COM port of the back-end
management terminal through a serial cable. One end of the serial cable is connected
to the RJ45 connector of the ZXR10 8905E, and the other end is connected to
the DB9 female connector of the back-end management terminal. For the wiring
sequence of the console cable, refer to Table 6-16.

Table 6-16 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port
The IPMC port connects to a back-end management terminal, which performs
operations and maintenance of the internal intelligent platform management system
of the ZXR10 8905E through the HyperTerminal. The IPMC port uses an RJ45
socket. It connects to the COM port of the back-end management terminal through a
serial cable. One end of the serial cable is connected to the RJ45 connector of the
ZXR10 8905E, and the other end is connected to the DB9 female connector of the
back-end management terminal. For the wiring sequence of the IPMC cable, refer
to Table 6-17.

Table 6-17 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port

The 8905EMCS1D card has a 10/100/1000Base-T Ethernet port (MGT) for connecting
to a back-end management system. It uses an RJ45 connector and an Category 5
UTP cable with the maximum transmission distance of 100 m.

l SD card slot

An SD card can be inserted to store system software and configuration information.


An SD card up to 32 GB is supported.

6-13

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Caution!
When information stored on the SD card is being read, the ACT indicator flashes. It's
not allowed to remove the SD card when it is being read to prevent data loss.

l PPS&TOD OUT
This port is used for GPS Pulse Per Second (PPS) and Time of Date (TOD) output. It
uses an RJ 45 connector and provides RS422 level output. For the wiring sequence
of the PPS&TOD OUT cable, refer to Table 6-18.

Table 6-18 Wiring Sequence of the PPS&TOD OUT Cable

RJ45 Signal RJ45 Signal

3 1PPS_OUT_N 6 1PPS_OUT_P

7 TOD_OUT_N 8 TOD_OUT_P

l PPS&TOD IN
This port is used for GPS PPS and TOD input. It uses an RJ45 connector and provides
RS422 level input. For the wiring sequence of the PPS&TOD IN cable, refer to Table
6-19.

Table 6-19 Wiring Sequence of the PPS&TOD IN Cable

RJ45 Signal RJ45 Signal

3 1PPS_IN_N 6 1PPS_IN_P

7 TOD_IN_N 8 TOD_IN_P

l BITS IN
This port is used for BITS signal input. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.
l BITS OUT

This port is used for BITS signal output. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.

Indicators
There are 23 indicators on the front panel of the 8905EMCS1D module. For a description
of these indicators, refer to Table 6-20.

6-14

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-20 8905EMCS1D Indicator Descriptions

Indicator Description

15 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

PWR15 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

Buttons
There are three buttons on the front panel of the 8905EMCS1D module. For a description
of these buttons, refer to Table 6-21.

Table 6-21 Button Descriptions

Button Description

RST Reset button: resets the module.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

6-15

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Technical Parameters
For technical parameters of the 8905EMCS1D module, refer to Table 6-22.

Table 6-22 8905EMCS1D Technical Parameters

Parameter Description

Silk screen name 8905EMCS1D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 56.5 W


Full-load power consumption: about 84.8 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version FLASH: 512 MB


Boot FLASH: 16 MB

Memory Slot One SODIMM slot

Maximum capacity 4 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (upper)


management port

RS232 Console Two-layer RJ45 port (lower)

SD card slot One

PPS&TOD OUT One

PPS&TOD IN One

BITS IN One

BITS OUT One

6.2.4 8902EMCS1D
Function
The 8902EMCS1D module is an enhanced MCS module of the ZXR10 8902E switch,
and provides the active/standby switchover function based on 1+1 redundancy. The
8902EMCS1D module supports Synchronous Ethernet, IEEE 1588v2, and GPS time
synchronization.
The 8902EMCS1D module provides the following functions:

l Gigabit out-of-band communication


It communicates with the CPU module of each line interface card.

6-16

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

l EPLD online upgrade


The EPLD of the 8902EMCS1D module provides the online upgrade function through
simulating the JTAG interface.
l JTAG test
The 8902EMCS1D module connects to main chips of line interface cards through a
daisy chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the module to implement real-time monitoring through the IIC bus.

l IPMC management and control unit


It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.

l Synchronous Ethernet & IEEE 1588v2 & GPS time synchronization


l Time synchronization through GPS or BITS.

Panel
For the 8902EMCS1D front panel, see Figure 6-4.

Figure 6-4 8902EMCS1D Front Panel

Interfaces
The 8902EMCS1D module provides the following interfaces:
l Console port
The console port connects to a back-end management terminal, which performs
operations and maintenance of the ZXR10 8902E through the HyperTerminal. The
console port uses an RJ45 socket. It connects to the COM port of the back-end
management terminal through a serial cable. One end of the serial cable is connected
to the RJ45 connector of the ZXR10 8902E, and the other end is connected to
the DB9 female connector of the back-end management terminal. For the wiring
sequence of the console cable, refer to Table 6-23.

6-17

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 6-23 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port

The IPMC port connects to a back-end management terminal, which performs


operations and maintenance of the internal intelligent platform management system
of the ZXR10 8902E through the HyperTerminal. The IPMC port uses an RJ45
socket. It connects to the COM port of the back-end management terminal through a
serial cable. One end of the serial cable is connected to the RJ45 connector of the
ZXR10 8902E, and the other end is connected to the DB9 female connector of the
back-end management terminal. For the wiring sequence of the IPMC cable, refer
to Table 6-24.

Table 6-24 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port


The 8902EMCS1D module has a 10/100/1000Base-T Ethernet port (MGT) for
connecting to a back-end management system. It uses an RJ45 connector and an
Category 5 UTP cable with the maximum transmission distance of 100 m.

l SD card slot
An SD card can be inserted to store system software and configuration information.
An SD card up to 32 GB is supported.

Caution!
When information stored on the SD card is being read, the ACT indicator flashes. It's
not allowed to remove the SD card when it is being read to prevent data loss.

l PPS&TOD OUT

6-18

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

This port is used for GPS Pulse Per Second (PPS) and Time of Date (TOD) output. It
uses an RJ 45 connector and provides RS422 level output. For the wiring sequence
of the PPS&TOD OUT cable, refer to Table 6-25.

Table 6-25 Wiring Sequence of the PPS&TOD OUT Cable

RJ45 Signal RJ45 Signal

3 1PPS_OUT_N 6 1PPS_OUT_P

7 TOD_OUT_N 8 TOD_OUT_P

l PPS&TOD IN

This port is used for GPS PPS and TOD input. It uses an RJ45 connector and provides
RS422 level input. For the wiring sequence of the PPS&TOD IN cable, refer to Table
6-26.

Table 6-26 Wiring Sequence of the PPS&TOD IN Cable

RJ45 Signal RJ45 Signal

3 1PPS_IN_N 6 1PPS_IN_P

7 TOD_IN_N 8 TOD_IN_P

l BITS IN
This port is used for BITS signal input. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.

l BITS OUT
This port is used for BITS signal output. It uses a BNC connector and connects to the
BITS network through a 75-ohm coaxial cable.

Indicators
There are 15 indicators on the front panel of the 8902EMCS1D module. For a description
of these indicators, refer to Table 6-27.

Table 6-27 8902EMCS1D Indicator Descriptions

Indicator Description

12 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

6-19

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

PWR12 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

FAN R (green) Not lit: Power is not properly supplied to the fan subrack.
Lit: Power is properly supplied to the fan subrack.

A (red) Not lit: The fan subrack operates normally.


Lit: The fan subrack has an alarm.

Buttons
There are three buttons on the front panel of the 8902EMCS1D module. For a description
of these buttons, refer to Table 6-28.

Table 6-28 Button Descriptions

Button Description

RST Reset button: resets the module.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

Technical Parameters
For technical parameters of the 8902EMCS1D module, refer to Table 6-29.

6-20

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-29 8902EMCS1D Technical Parameters

Parameter Description

Silk screen name 8902EMCS1D

Dimensions 373.1 mm 197.2 mm 40.3 mm

Power consumption Idle power consumption: 28.6 W


Full-load power consumption: about 31 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version FLASH: 512 MB


Boot FLASH: 16 MB

Memory Slot One SODIMM slot

Maximum capacity 4 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (right)


management port

RS232 Console Two-layer RJ45 port (left)

SD card slot One

PPS&TOD OUT One

PPS&TOD IN One

BITS IN One

BITS OUT One

6.2.5 8902EMCS1A
Functions
The 8902EMCS1A card is an enhanced MCS module of the ZXR10 8902E switch, and
provides the active/standby switchover function based on 1+1 redundancy.

The 8902EMCS1A card provides the following functions:


l Gigabit out-of-band communication

It communicates with the CPU module of each line interface card.

l EPLD online upgrade


The EPLD of the 8902EMCS1A card provides the online upgrade function by
simulating the JTAG interface.

l JTAG test

6-21

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

The 8902EMCS1A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control
It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.

Panel
For the front panel of the 8902EMCS1A card, see Figure 6-5.

Figure 6-5 Front Panel of the 8902EMCS1A Card

Interfaces
The 8902EMCS1A card provides the following interfaces:
l Console port
The console port connects to a back-end management terminal, which allows users to
operate and maintain the ZXR10 8902E through the HyperTerminal. The console port
uses an RJ45 socket, and connects to the COM port of the back-end management
terminal through a serial cable. One end of the serial cable is connected to the RJ45
connector of the ZXR10 8902E, and the other end is connected to the DB9 female
connector of the back-end management terminal. For the wiring sequence of the
console cable, refer to Table 6-30.

Table 6-30 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port
The IPMC port connects to a back-end management terminal, which allows users
to operate and maintain the internal intelligent platform management system of the

6-22

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

ZXR10 8902E through the HyperTerminal. The IPMC port uses an RJ45 socket, and
connects to the COM port of the back-end management terminal through a serial
cable. One end of the serial cable is connected to the RJ45 connector of the ZXR10
8902E, and the other end is connected to the DB9 female connector of the back-end
management terminal. For the wiring sequence of the IPMC cable, refer to Table 6-31.

Table 6-31 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port


The 8902EMCS1A card has a 10/100/1000Base-T Ethernet port (MGT) for connecting
to the back-end management system. It uses an RJ45 connector and a Category 5
UTP cable with the maximum transmission distance of 100 m.
l SD card slot

An SD card can be inserted into the SD card slot to store system software and
configuration information. An SD card up to 32 GB is supported.

Caution!

Do not remove the SD card when data in the SD card is being read. Failure to comply
will result in data loss.

Indicators
There are 15 indicators on the front panel of the 8902EMCS1A card. For a description of
these indicators, refer to Table 6-32.

Table 6-32 8902EMCS1A Card Indicator Descriptions

Indicator Description

12 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

6-23

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

PWR12 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS card is faulty.


(green) Flashing: The MCS card is operating normally.

ALM Not lit: The MCS card has no alarm.


(red) Lit: The MCS card has an alarm.

MST RUN Lit: The card is in active status.


(green) Not lit: The card is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is inserted.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: Data is being read from, or written into, the SD card.

FAN R (green) Not lit: Power is not properly supplied to the fan subrack.
Lit: Power is properly supplied to the fan subrack.

A (red) Not lit: The fan subrack operates normally.


Lit: The fan subrack has an alarm.

Buttons
There are three buttons on the front panel of the 8902EMCS1A card. For a description of
these buttons, refer to Table 6-33.

Table 6-33 Button Descriptions

Button Description

RST Reset button: resets the card.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

Technical Parameters
For technical parameters of the 8902EMCS1A card, refer to Table 6-34.

Table 6-34 8902EMCS1A Technical Parameters

Parameter Specification

Silk screen name 8902EMCS1A

6-24

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Parameter Specification

Dimensions 373.1 mm 197.2 mm 40.3 mm

Power consumption Static power consumption: 28.6 W


Operating power consumption: about 31 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version flash: 256 MB


Boot flash: 16 MB

Memory Maximum capacity 2 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (right)


management port

RS232 console Two-layer RJ45 port (left)


port

SD card slot One

6.2.6 8905EMCS1A
Functions
The 8905EMCS1A card is an enhanced MCS module of the ZXR10 8905E switch, and
provides the active/standby switchover function based on 1+1 redundancy.
The 8905EMCS1A card provides the following functions:
l Data switching with a large capacity
A single card provides a maximum switching capacity of 320 Gbps.
l Gigabit out-of-band communication
It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8905EMCS1A card provides the online upgrade function by
simulating the JTAG interface.
l JTAG test
The 8905EMCS1A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.

6-25

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

l IPMC management and control


It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent management system.

Panel
For the front panel of the 8905EMCS1A card, see Figure 6-6.

Figure 6-6 Front Panel of the 8905EMCS1A Card

Interfaces
The 8905EMCS1A card provides the following interfaces:

l Console port
The console port connects to a back-end management terminal, which allows
users to operate and maintain the ZXR10 8905E through the HyperTerminal. The
console port uses an RJ45 socket, and connects to the COM port of the back-end
management terminal through a serial console cable. One end of the serial console
cable is connected to the RJ45 connector of the ZXR10 8905E, and the other end is
connected to the DB9 female connector of the back-end management terminal. For
the wiring sequence of the console cable, refer to Table 6-35.

Table 6-35 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port

The IPMC port connects to a back-end management terminal, which allows users
to operate and maintain the internal intelligent platform management system of the
ZXR10 8905E through the HyperTerminal. The IPMC port uses an RJ45 socket, and
connects to the COM port of the back-end management terminal through a serial
cable. One end of the serial cable is connected to the RJ45 connector of the ZXR10
8905E, and the other end is connected to the DB9 female connector of the back-end
management terminal. For the wiring sequence of the IMPC cable, refer to Table 6-36.

6-26

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-36 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port

The 8905EMCS1A card has a 10/100/1000 Base-T Ethernet port (MGT) for
connecting to the back-end management system. It uses an RJ45 connector and a
Category 5 UTP cable with the maximum transmission distance of 100 m.

l SD card slot
An SD card can be inserted into the SD card slot to store system software and
configuration information. An SD card up to 4 GB is supported. A SanDisk or
Kingston SD card is recommended.

Caution!
Do not remove the SD card when data in the SD card is being read. Failure to comply
will result in data loss.

l USB(HOST) interface
A USB storage device can be inserted into the USB interface to store system software
and configuration information.

Indicators
There are 24 indicators on the front panel of the 8905EMCS1A card. For a description of
these indicators, refer to Table 6-37.

Table 6-37 8905EMCS1A Card Indicator Descriptions

Indicator Description

15 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

6-27

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS card is faulty.


(green) Flashing: The MCS card is operating normally.

ALM Not lit: The MCS card has no alarm.


(red) Lit: The MCS card has an alarm.

MST RUN Lit: The card is in active status.


(green) Not lit: The card is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the USB Lit: A USB storage device is connected to the interface.
interface Not lit: No USB storage device is connected to the interface.
Flashing: Data is being read from, or written into, the USB storage
device.

ACT (green) for the SD card Lit: An SD card is inserted.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: Data is being read from, or written into, the SD card.

ACT (yellow) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

Buttons
There are four buttons on the front panel of the 8905EMCS1A card. For a description of
these buttons, refer to Table 6-38.

Table 6-38 Button Descriptions

Button Description

RST Reset button: resets the card.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY for the SD card slot SD card copy button: copies the system software and
configuration information from the SD card to the flash
memory of the MCS card and restarts the MCS card.

6-28

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Button Description

CPY for the USB interface USB interface copy button: copies the system software and
configuration information from the USB storage device to the
flash memory of the MCS card and restarts the MCS card.

Technical Parameters
For technical parameters of the 8905EMCS1A card, refer to Table 6-39.

Table 6-39 8905EMCS1A Technical Parameters

Parameter Specification

Silk screen name 8905EMCS1A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Static power consumption: about 29 W


Operating power consumption: about 52 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum Version flash: 256 MB


capacity Boot flash: 16 MB

Memory Maximum 2 GB
capacity

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC One RJ45 port


management port

RS232 console One RJ45 port


port

SD card slot One

USB interface One

6.2.7 8908EMCS1A
Functions
The 8908EMCS1A card is an enhanced MCS module of the ZXR10 8908E switch, and
provides the active/standby switchover function based on 1+1 redundancy.

The 8908EMCS1A card provides the following functions:

l Data switching with a large capacity


A single card provides a maximum switching capacity of 512 Gbps.

6-29

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

l Gigabit out-of-band communication


It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8908EMCS1A card provides the online upgrade function by
simulating the JTAG interface.
l JTAG test
The 8908EMCS1A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control
It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent management system.

Panel
For the front panel of the 8908EMCS1A card, see Figure 6-7.

Figure 6-7 Front Panel of the 8908EMCS1A Card

Interfaces
The 8908EMCS1A card provides the following interfaces:
l Console port
The console port connects to a back-end management terminal, which allows users to
operate and maintain the ZXR10 8908E through the HyperTerminal. The console port
uses an RJ45 socket, and connects to the COM port of the back-end management
terminal through a serial console cable. One end of the serial cable is connected to
the RJ45 connector of the ZXR10 8908E, and the other end is connected to the DB9
female connector of the back-end management terminal. For the wiring sequence of
the serial cable, refer to Table 6-40.

Table 6-40 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6-30

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

RJ45 Signal DB9 (Back-End Signal


Computer)

6 T232RX 3 computerTX

l IPMC port
The IPMC port connects to a back-end management terminal, which allows users
to operate and maintain the internal intelligent platform management system of the
ZXR10 8908E through the HyperTerminal. The IPMC port uses an RJ45 socket, and
connects to the COM port of the back-end management terminal through a serial
cable. One end of the serial cable is connected to the RJ45 connector of the ZXR10
8908E, and the other end is connected to the DB9 female connector of the back-end
management terminal. For the wiring sequence of the IPMC cable, refer to Table 6-41.

Table 6-41 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port

The 8908EMCS1A card has a 10/100/1000 Base-T Ethernet port (MGT) for
connecting to the back-end management system. It uses an RJ45 connector and a
Category 5 UTP cable with the maximum transmission distance of 100 m.
l SD card slot
An SD card can be inserted into the SD card slot to store system software and
configuration information. An SD card up to 4 GB is supported. A SanDisk or
Kingston SD card is recommended.

Caution!
Do not remove the SD card when data in the SD card is being read. Failure to comply
will result in data loss.

l USB(HOST) interface

A USB storage device can be inserted into the USB interface to store system software
and configuration information.

6-31

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicators
There are 30 indicators on the front panel of the 8908EMCS1A card. For a description of
these indicators, refer to Table 6-42.

Table 6-42 8908EMCS1A Card Indicator Descriptions

Indicator Description

18 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS card is faulty.


(green) Flashing: The MCS card is operating normally.

ALM Not lit: The MCS card has no alarm.


(red) Lit: The MCS card has an alarm.

MST RUN Lit: The card is in active status.


(green) Not lit: The card is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the USB Lit: A USB storage device is connected to the interface.
interface Not lit: No USB storage device is connected to the interface.
Flashing: Data is being read from, or written into, the USB storage
device.

ACT (green) for the SD card Lit: An SD card is inserted.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: Data is being read from, or written into, the SD card.

ACT (yellow) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

Buttons
There are four buttons on the front panel of the 8908EMCS1A card. For a description of
these buttons, refer to Table 6-43.

6-32

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-43 Button Descriptions

Button Description

RST Reset button: resets the card.

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY for the SD card slot SD card copy button: copies the system software and
configuration information from the SD card to the flash
memory of the MCS card and restarts the MCS card.

CPY for the USB interface USB interface copy button: copies the system software and
configuration information from the USB storage device to the
flash memory of the MCS card and restarts the MCS card.

Technical Parameters
For technical parameters of the 8908EMCS1A card, refer to Table 6-44.

Table 6-44 8908EMCS1A Technical Parameters

Parameter Specification

Silk screen name 8908EMCS1A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Static power consumption: about 29 W


Operating power consumption: about 52 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version flash: 256 MB


Boot flash: 16 MB

Memory Maximum capacity 2 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC One RJ45 port


management port

RS232 console One RJ45 port


port

SD card slot One

USB interface One

6-33

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

6.2.8 8912EMCS1A
Functions
The 8912EMCS1A card is an enhanced MCS module of the ZXR10 8912E switch, and
provides the active/standby switchover function based on 1+1 redundancy.
The 8912EMCS1A card provides the following functions:
l Data switching with a large capacity
A single card provides a maximum switching capacity of 1024 Gbps.
l Gigabit out-of-band communication
It communicates with the CPU module of each line interface card.
l EPLD online upgrade
The EPLD of the 8912EMCS1A card provides the online upgrade function by
simulating the JTAG interface.
l JTAG test
The 8912EMCS1A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control
It connects to the IPMC management and control unit of each line interface card
through a bus to establish an intelligent platform management system.

Panel
For the front panel of the 8912EMCS1A card, see Figure 6-8.

Figure 6-8 Front Panel of the 8912EMCS1A Card

Interfaces
The 8912EMCS1A card provides the following interfaces:
l Console port
The console port connects to a back-end management terminal, which allows users to
operate and maintain the ZXR10 8912E through the HyperTerminal. The console port
uses an RJ45 socket, and connects to the COM port of the back-end management
terminal through a serial cable. One end of the serial cable is connected to the RJ45

6-34

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

connector of the ZXR10 8912E, and the other end is connected to the DB9 female
connector of the back-end management terminal. For the wiring sequence of the
console cable, refer to Table 6-45.

Table 6-45 Wiring Sequence of the Console Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l IPMC port
The IPMC port connects to a back-end management terminal, which allows users
to operate and maintain the internal intelligent platform management system of the
ZXR10 8912E through the HyperTerminal. The IPMC port uses an RJ45 socket, and
connects to the COM port of the back-end management terminal through a serial
cable. One end of the serial cable is connected to the RJ45 connector of the ZXR10
8912E, and the other end is connected to the DB9 female connector of the back-end
management terminal. For the wiring sequence of the IPMC cable, refer to Table 6-46.

Table 6-46 Wiring Sequence of the IPMC Cable

RJ45 Signal DB9 (Back-End Signal


Computer)

3 T232TX 2 computerRX

5 GND 5 GND

6 T232RX 3 computerTX

l 10/100/1000 Base-T Ethernet port


The 8912EMCS1A card has a 10/100/1000Base-T Ethernet port (MGT) for connecting
to the back-end management system. It uses an RJ45 connector and a Category 5
UTP cable with the maximum transmission distance of 100 m.

l SD card slot
An SD card can be inserted into the SD card slot to store system software and
configuration information. An SD card up to 32 GB is supported.

Caution!
Do not remove the SD card when data in the SD card is being read. Failure to comply
will result in data loss.

6-35

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicators
There are 37 indicators on the front panel of the 8912EMCS1A card. For a description of
these indicators, refer to Table 6-47.

Table 6-47 8912EMCS1A Card Indicator Descriptions

Indicator Description

112 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS card is faulty.


(green) Flashing: The MCS card is operating normally.

ALM Not lit: The MCS card has no alarm.


(red) Lit: The MCS card has an alarm.

MST RUN Lit: The card is in active status.


(green) Not lit: The card is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is inserted.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: Data is being read from, or written into, the SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

Buttons
There are three buttons on the front panel of the 8912EMCS1A card. For a description of
these buttons, refer to Table 6-48.

Table 6-48 Button Descriptions

Button Description

RST Reset button: resets the card.

6-36

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Button Description

EXCH Active/standby switchover button. If users press this button


on a standby board, no change occurs.

CPY Reserved.

Technical Parameters
For technical parameters of the 8912EMCS1A card, refer to Table 6-49.

Table 6-49 8912EMCS1A Technical Parameters

Parameter Specification

Silk screen name 8912EMCS1A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Static power consumption: about 56.5 W


Operating power consumption: about 84.8 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Flash Maximum capacity Version flash: 256 MB


Boot flash: 16 MB

Memory Maximum capacity 2 GB

Interface 10/100/1000M One RJ45 port


Ethernet
management port

IPMC Two-layer RJ45 port (upper)


management port

RS232 console Two-layer RJ45 port (lower)


port

SD card slot One

6.3 Line Interface Cards


6.3.1 H2GF48D
Function
The H2GF48D card provides 48 MPLS GE optical interfaces for wire-speed access. It is
applicable to all the ZXR10 8900E series switches and provides the Synchronous Ethernet,
IEEE 1588v2, and OAM functions.
The H2GF48D card provides the following functions:
l Large switching capacity

6-37

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

It provides 48 GE optical interfaces for wire-speed forwarding and supports large table
entries and the MPLS function.
l Gigabit out-of-band communication
The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the H2GF48D card provides the online upgrade function through
simulating the JTAG interface.
l JTAG test

The H2GF48D card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection

Temperature, voltage, and power consumption monitoring circuits are designed on


the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2
It supports Synchronous Ethernet & IEEE 1588v2 time synchronization.
l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the H2GF48D front panel, see Figure 6-9.

Figure 6-9 H2GF48D Front Panel

Interfaces
The H2GF48D card uses hot-swappable SFP optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-50.

6-38

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-50 H2GF48D Card Interface Descriptions

Interface Description

1000BASE-SX (SFP-M500) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
500 m
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -18 dBm, overload power: 0 dBm

1000BASE-SX (SFP-M500-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
500 m, with the digital diagnosis function
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -17 dBm, overload power: 0 dBm

1000BASE-LX (SFP-S10K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km
Transmission power range: -9.5 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S10K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km, with the digital diagnosis function
Transmission power range: -9 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -4.5 dBm to 5 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -22 dBm, overload power: -3 dBm

1000BASE-LH (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 3 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

6-39

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

1000BASE-LH (SFP-S120K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 120 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -30 dBm, overload power: -9 dBm

100BASE-FX (SFP-M2K-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -10 dBm

LC connector, connected with a multi-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -14 dBm

100BASE-FX (SFP-S15K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S15K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km, with the digital diagnosis function
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S40K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -36 dBm, overload power: -10 dBm

100BASE-FX (SFP-S80K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -8 dBm

6-40

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

100BASE-FX (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -5 dBm to 5 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S100K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -34 dBm

1.25G single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1490 nm RX, maximum
module (SFP-S10K-D-S) transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum
transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

1.25G single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1490 nm RX, maximum
module (SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum
transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

6-41

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

155M single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1550 nm RX, maximum
module (SFP-S15K-D-S) transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

155M single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1550 nm RX, maximum
module (SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -10 dBm

For H2GF48D card interface attributes, refer to Table 6-51.

Table 6-51 H2GF48D Card Interface Attributes

Attribute Specification

Connector LC

Technical specifications Depending on the type of SFP module used

Operating mode Full duplex

Standard IEEE802.3z Gigabit Ethernet standard

Frame format Ethernet frame

Network protocol Ethernet

Indicators
There are 48 indicators on the front panel of the H2GF48D card, indicating the operation
of 48 optical interfaces respectively. For a description of these optical interface indicators,
refer to Table 6-52.

6-42

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-52 H2GF48D Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

Technical Parameters
For technical parameters of the H2GF48D card, refer to Table 6-53.

Table 6-53 H2GF48D Technical Parameters

Parameter Specification

Silk screen name H2GF48D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 40.2 W


Power consumption without any optical module: 51.7 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 4 GB

6.3.2 H2GF24D
Function
The H2GF24D card provides 24 MPLS GE optical interfaces for wire-speed access. It is
applicable to all the ZXR10 8900E series switches and provides the Synchronous Ethernet,
IEEE 1588v2, and OAM functions.
The H2GF24D card provides the following functions:
l Large switching capacity
It provides 24 GE optical interfaces for wire-speed forwarding and supports large table
entries and the MPLS function.

l Gigabit out-of-band communication

The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.

l EPLD online upgrade

The EPLD of the H2GF24D card provides the online upgrade function through
simulating the JTAG interface.

l JTAG test

6-43

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

The H2GF24D card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2

It supports Synchronous Ethernet and IEEE 1588v2 time synchronization.


l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the H2GF24D front panel, see Figure 6-10.

Figure 6-10 H2GF24D Front Panel

Interfaces
The H2GF24D card uses hot-swappable SFP optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-54.

Table 6-54 H2GF24D Card Interface Descriptions

Interface Description

1000BASE-SX (SFP-M500) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
500 m
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -18 dBm, overload power: 0 dBm

1000BASE-SX (SFP-M500-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
500 m, with the digital diagnosis function
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -17 dBm, overload power: 0 dBm

6-44

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

1000BASE-LX (SFP-S10K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km
Transmission power range: -9.5 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S10K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km, with the digital diagnosis function
Transmission power range: -9 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -4.5 dBm to 5 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -22 dBm, overload power: -3 dBm

1000BASE-LH (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 3 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

1000BASE-LH (SFP-S120K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 120 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -30 dBm, overload power: -9 dBm

100BASE-FX (SFP-M2K-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -10 dBm

LC connector, connected with a multi-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -14 dBm

6-45

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

100BASE-FX (SFP-S15K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S15K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km, with the digital diagnosis function
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S40K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -36 dBm, overload power: -10 dBm

100BASE-FX (SFP-S80K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -8 dBm

100BASE-FX (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -5 dBm to 5 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S100K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -34 dBm

6-46

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

1.25G single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1490 nm RX, maximum
module (SFP-S10K-D-S) transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum
transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

1.25G single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1490 nm RX, maximum
module (SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum
transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

155M single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1550 nm RX, maximum
module (SFP-S15K-D-S) transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

6-47

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

155M single-fiber and bidirectional LC connector, connected with a single-mode optical fiber,
SFP transmitting/receiving optical optical wavelength: 1310 nm TX/1550 nm RX, maximum
module (SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -10 dBm

For H2GF24D card interface attributes, refer to Table 6-55.

Table 6-55 H2GF24D Card Interface Attributes

Attribute Specification

Connector LC

Technical specifications Depending on the type of SFP module used

Operating mode Full duplex

Standard IEEE802.3z Gigabit Ethernet standard

Frame format Ethernet frame

Network protocol Ethernet

Indicators
There are 24 indicators on the front panel of the H2GF24D card, indicating the operation
of 24 optical interfaces respectively. For a description of these optical interface indicators,
refer to Table 6-56.

Table 6-56 H2GF24D Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

Technical Parameters
For technical parameters of the H2GF24D card, refer to Table 6-57.

6-48

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Table 6-57 H2GF24D Technical Parameters

Parameter Specification

Silk screen name H2GF24D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 40.2 W


Power consumption without any optical module: 51.7 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 4 GB

6.3.3 H2GT48D
Function
The H2GT48D card provides 48 MPLS GE electrical interfaces for wire-speed
1000BASE-T access. It is applicable to all the ZXR10 8900E series switches and provides
the Synchronous Ethernet, IEEE 1588v2, and OAM functions.
The H2GT48D card provides the following functions:
l Large switching capacity
It provides 48 GE electrical interfaces for wire-speed forwarding and supports large
table entries and the MPLS function.
l Gigabit out-of-band communication
The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the H2GT48D card provides the online upgrade function through
simulating the JTAG interface.
l JTAG test
The H2GT48D card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2

6-49

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

It supports Synchronous Ethernet and IEEE 1588v2 time synchronization.


l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the H2GT48D front panel, see Figure 6-11.

Figure 6-11 H2GT48D Front Panel

Interfaces
The H2GT48D card uses RJ45 electrical interfaces for all the 48 ports. For a description
of these interfaces, refer to Table 6-58.

Table 6-58 H2GT48D Card Interface Descriptions

Interface Description

10/100/1000Base-T Complies with the IEEE 802.3z standard.


RJ45 connector.
Uses a Category 5 UTP cable.
Maximum transmission distance: 100 m.
MDI/MDIX.

Indicators
There are 48 indicators on the front panel of the H2GT48D card, indicating the operation
of 48 electrical interfaces respectively. For a description of these interface indicators, refer
to Table 6-59.

Table 6-59 H2GT48D Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

Technical Parameters
For technical parameters of the H2GT48D card, refer to Table 6-60.

Table 6-60 H2GT48D Technical Parameters

Parameter Description

Silk screen name H2GT48D

6-50

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Parameter Description

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 49.5 W


Power consumption without network cables installed: 58.5 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 4 GB

6.3.4 H2XF8D
Function
The H2XF8D card provides eight 10-GE optical interfaces for wire-speed access. It is
applicable to the ZXR10 8912E/8908E/8905E switch only (if installed on the ZXR10 8912E,
it can be installed on any of the first four slots only). It supports the Synchronous Ethernet,
IEEE 1588v2, and OAM functions.
The H2XF8D card provides the following functions:
l Large switching capacity
It provides eight 10-GE optical interfaces for wire-speed forwarding and supports large
table entries and the MPLS function.
l Gigabit out-of-band communication
The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the H2XF8D card provides the online upgrade function through
simulating the JTAG interface.
l JTAG test
The H2XF8D card connects to main chips of line interface cards through a daisy chain
to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2
l Power supply management

6-51

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

A power management chip can control the power-on sequence of devices. A power
management chip can control the power-on sequence of devices.

Panel
For the H2XF8D front panel, see Figure 6-12.

Figure 6-12 H2XF8D Front Panel

Interfaces
The H2XF8D card uses hot-swappable SFP+ optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-61.

Table 6-61 H2XF8D Card Interface Descriptions

Interface Description

10 GBASE-SR (SFP+-300-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
300 m, with the digital diagnosis function
Output optical modulation amplitude: -2.8 dBm, receiving
sensitivity: -11.1 dBm, overload power: 0.5 dBm

10 GBASE-LR (SFP+-S10K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km, with the digital diagnosis function
Output optical modulation amplitude: -5.2 dBm, receiving
sensitivity: -12.6 dBm, overload power: 0.5 dBm

10 GBASE-ER&EW (SFP+-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Output optical modulation amplitude: -2.1 dBm, receiving
sensitivity: -14.1 dBm, overload power: -1 dBm

For H2XF8D card interface attributes, refer to Table 6-62.

Table 6-62 H2XF8D Card Interface Attributes

Attribute Specification

Connector Duplex LC

Technical specifications Depending on the type of SFP+ module used

Operating mode Full duplex

Standard IEEE 802.3ae 10 GBASE-R

6-52

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Attribute Specification

Frame format Ethernet frame

Network protocol Ethernet

Indicators
There are eight indicators on the front panel of the H2XF8D card, indicating the operation of
eight optical interfaces respectively. For a description of these optical interface indicators,
refer to Table 6-63.

Table 6-63 H2XF8D Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

Technical Parameters
For technical parameters of the H2XF8D card, refer to Table 6-64.

Table 6-64 H2XF8D Technical Parameters

Parameter Specification

Silk screen name H2XF8D

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 71.0 W


Power consumption without any optical module: 80.9 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 4 GB

Caution!

The H2XF8D card is applicable only to the ZXR10 8908E/8905E switch and the first four
slots of the ZXR10 8912E.

6-53

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

6.3.5 S1XF12A
Function
The S1XF12A card provides 12 10-GE optical interfaces for wire-speed access. It is
applicable to all the ZXR10 8900E series switches and provides the Synchronous Ethernet
function.
The S1XF12A card provides the following functions:
l Large switching capacity
It provides 12 10-GE SFP+ optical interfaces for wire-speed forwarding.
l Gigabit out-of-band communication
The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S1XF12A card provides the online upgrade function through
simulating the JTAG interface.
l JTAG test
The S1XF12A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet
It supports Synchronous Ethernet time synchronization.
l Power supply management
A power management chip can control the power-on sequence of devices. A power
management chip can control the power-on sequence of devices.

Panel
For the S1XF12A front panel, see Figure 6-13.

Figure 6-13 S1XF12A Front Panel

6-54

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interfaces
The S1XF12A card uses hot-swappable SFP+ optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-65.

Table 6-65 S1XF12A Card Interface Descriptions

Interface Description

10 GBASE-SR (SFP+-300-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 850 nm, maximum transmission distance:
300 m, with the digital diagnosis function
Output optical modulation amplitude: -2.8 dBm, receiving
sensitivity: -11.1 dBm, overload power: 0.5 dBm

10 GBASE-LR (SFP+-S10K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km, with the digital diagnosis function
Output optical modulation amplitude: -5.2 dBm, receiving
sensitivity: -12.6 dBm, overload power: 0.5 dBm

10 GBASE-ER&EW (SFP+-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Output optical modulation amplitude: -2.1 dBm, receiving
sensitivity: -14.1 dBm, overload power: -1 dBm

For S1XF12A card interface attributes, refer to Table 6-66.

Table 6-66 S1XF12A Card Interface Attributes

Attribute Specification

Connector Duplex LC

Technical specifications Depending on the type of SFP+ module used

Operating mode Full duplex

Standard IEEE 802.3ae 10 GBASE-R

Frame format Ethernet frame

Network protocol Ethernet

Indicators
There are 12 indicators on the front panel of the S1XF12A card, indicating the operation
of 12 optical interfaces respectively. For a description of these interface indicators, refer
to Table 6-67.

6-55

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 6-67 S1XF12A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

Technical Parameters
For technical parameters of the S1XF12A card, refer to Table 6-68.

Table 6-68 S1XF12A Technical Parameters

Parameter Specification

Silk screen name S1XF12A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Idle power consumption: about 51.3 W


Power consumption without any optical module: 60.7 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 4 GB

6.3.6 S2LQ6L2A
Function
The S2LQ6L2A card provides eight 40-GE optical interfaces (two CFP interfaces and six
QSFP interfaces). It is applicable to all the ZXR10 8900E series switches and provides
the MPLS 40-GE wire-speed access, Synchronous Ethernet, IEEE 1588v2, and OAM
functions.
The S2LQ6L2A card provides the following functions:
l Large switching capacity
It provides eight 40-GE optical interfaces (six QSFP interfaces and two CFP
interfaces).
l Gigabit out-of-band communication
The MCS module communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S2LQ6L2A card provides the online upgrade function through
simulating the JTAG interface.
l JTAG test

6-56

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

The S2LQ6L2A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS module through a
bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2

It supports Synchronous Ethernet and IEEE 1588v2 time synchronization.


l Power supply management
A power management chip can control the power-on sequence of devices. A power
management chip can control the power-on sequence of devices.

Panel
For the S2LQ6L2A front panel, see Figure 6-14.

Figure 6-14 S2LQ6L2A Front Panel

Interfaces
The S2LQ6L2A card provides QSFP and CFP interfaces, both of which are hot swappable.
For a description of the interfaces, refer to Table 6-69.

Table 6-69 S2LQ6L2A Card Interface Descriptions

Interface Description

40 GBASE-SR4 (QSFP+-150-D) l Data rate: 10.3125 Gbps (single channel)


l Optical wavelength: 850 nm
l Output power: -7.6 dBm to -2.4 dBm (single channel)
l Extinction ratio: 3.0 dB
l Sensitivity: -5.4 dBm (single channel)
l Overload: 3.4 dBm (single channel)
l Transmission distance: 150 m (OM4 optical fiber)
l Encapsulation: compliant with the MSA standard scale
of QSFP

6-57

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

40 GBASE-LR4 (CFP-S10K-D) l Data rate: 4 10G


l Optical wavelength: 1270 nm, 1290 nm, 1310 nm, 1330
nm
l Output power: -7 to +2.3 dBm (each channel)
l Extinction ratio: 3.5 dB
l Sensitivity: -11.5 dBm
l Overload: 3.3 dBm
l Transmission distance: 10 km
l Encapsulation: 148-pin CFP MSA
l LC optical connector

For S2LQ6L2A card interface attributes, refer to Table 6-70.

Table 6-70 S2LQ6L2A Card Interface Attributes

Attribute Specification

Connector LC, SC, MPO

Technical specifications Depending on the QSFP and CFP modules used

Operating mode Full duplex

Standard IEEE P802.3ba 40 GBASE-SR4, IEEE P802.3ba


40 GBASE-LR4

Frame format Ethernet frame

Network protocol Ethernet

For optical module attributes, refer to Table 6-71.

Table 6-71 Optical Module Attributes

Attribute Specification

QSFP CFP

Transmission distance OM3100 m, OM4150 m 10 km

Central wavelength 850 nm 1270 nm, 1290 nm, 1310 nm,


1330 nm

Minimum optical power for -7.6 dBm -7 dBm


transmission

Maximum optical power for 2.4 dBm 2.3 dBm


transmission

receiving sensitivity -5.4 dBm -11.5 dBm

Overload optical power 4.0 dBm 3.5 dBm

Fiber type Multi mode Single mode

6-58

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Indicators
There are six indicators for the QSFP interfaces and two indicators for the CFP interfaces
on the front panel of the S2LQ6L2A card. For a description of these indicators, refer to
Table 6-72.

Table 6-72 S2LQ6L2A Interface Indicator Descriptions

Indicator Description

LINK/ACT l Lit: A link is established.


l Not lit: There is no connection with this interface.
l Flashing: Data is being sent or received through this
interface.

Technical Parameters
For technical parameters of the S2LQ6L2A card, refer to Table 6-73.

Table 6-73 S2LQ6L2A Technical Parameters

Parameter Specification

Silk screen name S2LQ6L2A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Static power consumption: about 90 W


Full-load power consumption: 120 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One DIMM slot

Maximum 4 GB
capacity

6.3.7 S2XF48A
Functions
The S2XF48A card provides forty-eight 10-GE optical interfaces for wire-speed access. It
is applicable to the 8912E/8908E/8905E/8902E switch only. It supports the Synchronous
Ethernet, IEEE 1588v2, and OAM functions.
The S2XF48A card provides the following functions:
l Data switching with a large capacity
It provides forty-eight 10-GE SFP+ optical interfaces.
l Gigabit out-of-band communication
The MCS card communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.

6-59

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

l EPLD online upgrade


The EPLD of the S2XF48A card provides the online upgrade function by simulating
the JTAG interface.
l JTAG test
The S2XF48A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
Temperature, voltage, and power consumption monitoring circuits are designed on
the card to implement real-time monitoring through the IIC bus.
l IPMC management and control
The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2
It supports Synchronous Ethernet and IEEE 1588v2 time synchronization.
l Power supply management
A power management chip can control the power-on sequence of devices. A power
management chip can control the power-on sequence of devices.

Panel
For the front panel of the S2XF48A card, see Figure 6-15.

Figure 6-15 Front Panel of the S2XF48A Card

Interfaces
The S2XF48A card uses hot-swappable SFP+ optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-74.

Table 6-74 S2XF48A Card Interface Descriptions

Interface Description

10 GBASE-SR (SFP+-300-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 850 nm,
maximum transmission distance: 300 m, with the
digital diagnosis function
Transmission power range: -7.3 dBm to -1
dBm, receiving sensitivity: -11.1 dBm, overload
power: 0.5 dBm

6-60

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

10 GBASE-LR (SFP+-S10K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 10 km, with the
digital diagnosis function
Transmission power range: -8.2 dBm to 0.5
dBm, receiving sensitivity: -10.3 dBm, overload
power: 0.5 dBm

10 GBASE-ER&EW (SFP+-S40K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 40 km, with the
digital diagnosis function
Transmission power range: -4.7 dBm to 4 dBm,
receiving sensitivity: -14.1 dBm, overload
power: -1 dBm

10 GBASE-ER&EW (SFP+-S80K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: 0 dBm to 4 dBm,
receiving sensitivity: -24 dBm, overload power:
-7 dBm

For a description of the S2XF48A card interfaces, refer to Table 6-75.

Table 6-75 S2XF48A Card Interface Attributes

Attribute Specification

Connector Duplex LC.

Optical interface attribute Depends on the specific SFP+ module.

Operating mode Full duplex.

Standard IEEE 802.3ae 10 GBASE-R.

Frame format Ethernet frame.

Network protocol Ethernet.

Indicators
There are eight indicators on the front panel of the S2XF48A card, indicating the operation
of eight optical interfaces respectively. For a description of these interface indicators, refer
to Table 6-76.

6-61

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 6-76 S2XF48A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this interface.

Technical Parameters
For technical parameters of the S2XF48A card, refer to Table 6-77.

Table 6-77 S2XF48A Technical Parameters

Parameter Specification

Silk screen name S2XF48A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Full-load power consumption: 180 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One DIMM slot

Maximum 4 GB
capacity

6.3.8 S1GF48A
Functions
The S1GF48A card provides 48 GE optical interfaces for wire-speed access. It is
applicable to all the ZXR10 8900E series switches and supports the Synchronous
Ethernet function.
The S1GF48A card provides the following functions:
l Data switching with a large capacity
It provides 48 GE SFP optical interfaces for wire-speed forwarding.
l Gigabit out-of-band communication
The MCS card communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S1GF48A card provides the online upgrade function by simulating
the JTAG interface.
l JTAG test
The S1GF48A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.

6-62

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control
The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.
l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the front panel of the S1GF48A card, see Figure 6-16.

Figure 6-16 Front Panel of the S1GF48A Card

Interfaces
The S1GF48A card uses hot-swappable SFP optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-78.

Table 6-78 S1GF48A Card Interface Descriptions

Interface Description

1000BASE-SX (SFP-M500) LC connector, connected with a multi-mode


optical fiber, optical wavelength: 850 nm,
maximum transmission distance: 500 m
Transmission power range: -9.5 dBm to -4 dBm,
receiving sensitivity: -18 dBm, overload power:
0 dbm

1000BASE-SX (SFP-M500-D) LC connector, connected with a multi-mode


optical fiber, optical wavelength: 850 nm,
maximum transmission distance: 500 m, with the
digital diagnosis function
Transmission power range: -9.5 dBm to -4 dBm,
receiving sensitivity: -17 dBm, overload power:
0 dbm

6-63

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

1000BASE-LX (SFP-S10K) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 10 km
Transmission power range: -9.5 dBm to -3 dBm,
receiving sensitivity: -20 dBm, overload power:
-3 dbm

1000BASE-LX (SFP-S10K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 10 km, with the
digital diagnosis function
Transmission power range: -9 dBm to -3 dBm,
receiving sensitivity: -20 dBm, overload power:
-3 dbm

1000BASE-LX (SFP-S40K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 40 km, with the
digital diagnosis function
Transmission power range: -4.5 dBm to 5 dBm,
receiving sensitivity: -22 dBm, overload power:
-5 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 40 km, with the
digital diagnosis function
Transmission power range: -5 dBm to 0 dBm,
receiving sensitivity: -22 dBm, overload power:
-3 dbm

1000BASE-LH (SFP-S80K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: 0 dBm to 3 dBm,
receiving sensitivity: -22 dBm, overload power:
-5 dbm

1000BASE-LH (SFP-S120K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 120 km, with
the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm,
receiving sensitivity: -30 dBm, overload power:
-9 dbm

6-64

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

100BASE-FX (SFP-M2K-D) LC connector, connected with a multi-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 2 km, with the
digital diagnosis function
Transmission power range: -19 dBm to -14 dBm,
receiving sensitivity: -30 dBm, overload power:
-10 dbm

LC connector, connected with a multi-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 2 km, with the
digital diagnosis function
Transmission power range: -19 dBm to -14 dBm,
receiving sensitivity: -30 dBm, overload power:
-14 dbm

100BASE-FX (SFP-S15K) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 15 km
Transmission power range: -8 dBm to -14 dBm,
receiving sensitivity: -31 dBm, overload power:
-8 dbm

100BASE-FX (SFP-S15K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 15 km, with the
digital diagnosis function
Transmission power range: -8 dBm to -14 dBm,
receiving sensitivity: -31 dBm, overload power:
-8 dbm

100BASE-FX (SFP-S40K) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 40 km
Transmission power range: -4 dBm to 0 dBm,
receiving sensitivity: -37 dBm, overload power:
-10 dbm

100BASE-FX (SFP-S40K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 40 km, with the
digital diagnosis function
Transmission power range: -5 dBm to 0 dBm,
receiving sensitivity: -36 dBm, overload power:
-10 dbm

6-65

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

100BASE-FX (SFP-S80K) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km
Transmission power range: -4 dBm to 0 dBm,
receiving sensitivity: -37 dBm, overload power:
-8 dbm

100BASE-FX (SFP-S80K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: -3 dBm to 3 dBm,
receiving sensitivity: -37 dBm, overload power:
-10 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: -5 dBm to 5 dBm,
receiving sensitivity: -37 dBm, overload power:
-10 dbm

100BASE-FX (SFP-S100K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: 0 dBm to 5 dBm,
receiving sensitivity: -34 dBm

1.25G two-way single-fiber SFP transceiver LC connector, connected with a single-mode


module (SFP-S10K-D-S) optical fiber, optical wavelength: 1310 nm
TX/1490 nm RX, maximum transmission
distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm,
receiving sensitivity: -19.5 dBm, overload
power: -3 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1490 nm
TX/1310 nm RX, maximum transmission
distance: 10 km, with the digital diagnosis
function

6-66

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

Transmission power range: -9 dBm to 3 dBm,


receiving sensitivity: -19.5 dBm, overload
power: -3 dbm

1.25G two-way single-fiber SFP transceiver LC connector, connected with a single-mode


module (SFP-S40K-D-S) optical fiber, optical wavelength: 1310 nm
TX/1490 nm RX, maximum transmission
distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm,
receiving sensitivity: -19.5 dBm, overload
power: -3 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1490 nm
TX/1310 nm RX, maximum transmission
distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm,
receiving sensitivity: -19.5 dBm, overload
power: -3 dbm

155M two-way single-fiber SFP transceiver LC connector, connected with a single-mode


module (SFP-S15K-D-S) optical fiber, optical wavelength: 1310 nm
TX/1550 nm RX, maximum transmission
distance: 15km, with the digital diagnosis function
Transmission power range: -14 dBm to -8 dBm,
receiving sensitivity: -31 dBm, overload power:
-8 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm
TX/1310 nm RX, maximum transmission
distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm,
receiving sensitivity: -31 dBm, overload power:
-8 dbm

6-67

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

155M two-way single-fiber SFP transceiver LC connector, connected with a single-mode


module (SFP-S40K-D-S) optical fiber, optical wavelength: 1310 nm
TX/1550 nm RX, maximum transmission
distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm,
receiving sensitivity: -34 dBm, overload power:
-3 dbm

LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm
TX/1310 nm RX, maximum transmission
distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm,
receiving sensitivity: -34 dBm, overload power:
-10 dbm

For S1GF48A card interface attributes, refer to Table 6-79.

Table 6-79 S1GF48A Card Interface Attributes

Attribute Specification

Connector LC.

Optical interface attribute Depends on the specific SFP optical module.

Operating mode Full duplex.

Standard IEEE 802.3ae 10GBASE-R.

Frame format Ethernet frame.

Network protocol Ethernet.

Indicators
There are 48 indicators on the front panel of the S1GF48A card, indicating the operation
of 48 optical interfaces respectively. For a description of these optical interface indicators,
refer to Table 6-80.

Table 6-80 S1GF48A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this interface.

6-68

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Technical Parameters
For technical parameters of the S1GF48A card, refer to Table 6-81.

Table 6-81 S1GF48A Technical Parameters

Parameter Specification

Silk screen name S1GF48A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Maximum power consumption: 67.7 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

Memory Slot One SODIMM slot

Maximum capacity 1 GB

6.3.9 S1GT48A
Functions
The S1GT48A card provides 48 GE electrical interfaces (1000BASE-T). It is applicable to
all the ZXR10 8900E series switches, and supports the MPLS GE wire-speed access and
48-port POE (or 24-port POE+) functions.
The S1GT48A card provides the following functions:
l Data switching with a large capacity
It provides 48 GE electrical interfaces for MPLS wire-speed forwarding and supports
the 48-port POE (or 24-port POE+) function.
l Gigabit out-of-band communication
The MCS card communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S1GT48A card provides the online upgrade function by simulating
the JTAG interface.
l JTAG test

The S1GT48A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection

The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.

l IPMC management and control

6-69

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.
l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the front panel of the S1GT48A card, see Figure 6-17.

Figure 6-17 Front Panel of the S1GT48A Card

Interfaces
The S1GT48A card uses RJ45 electrical interfaces for all the 48 ports. For a description
of these interfaces, refer to Table 6-82.

Table 6-82 S1GT48A Card Interface Descriptions

Interface Description

10/100/1000Base-T Complies with the IEEE 802.3z standard.


Uses RJ45 connectors and CAT5 UTP cables.
Maximum transmission distance: 100 m.
MDI/MDIX.

Indicators
There are 48 indicators on the front panel of the S1GT48A card, indicating the operation
of 48 electrical interfaces respectively. For a description of these electrical interface
indicators, refer to Table 6-83.

Table 6-83 S1GT48A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this interface.

Technical Parameters
For technical parameters of the S1GT48A card, refer to Table 6-84.

Table 6-84 S1GT48A Technical Parameters

Parameter Specification

Silk screen name S1GT48A

6-70

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Parameter Specification

Dimensions 366.7 mm 338.8 mm 2.4 mm

Power consumption Static power consumption: about 37.8 W


Operating power consumption without Ethernet cables
connected: 60 W

CPU Capacity Single-core CPU, CPU speed: 800 MHz

Memory Maximum 2 GB
capacity

6.3.10 S2XF4A
Functions
The S2XF4A card provides four 10-GE optical interfaces for wire-speed access. It is
applicable to the 8912E/8908E/8905E/8902E switch only. It supports the Synchronous
Ethernet, IEEE 1588v2, and OAM functions.
The S2XF4A card provides the following functions:
l Data switching with a large capacity
It provides four 10-GE SFP+ optical interfaces.
l Gigabit out-of-band communication
The MCS card communicates with the CPU of the card through this function, for
example, downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S2XF4A card provides the online upgrade function by simulating the
JTAG interface.
l JTAG test
The S2XF4A card connects to main chips of line interface cards through a daisy chain
to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control
The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.
l Synchronous Ethernet & IEEE 1588v2
Synchronous Ethernet & IEEE 1588v2
l Power supply management

6-71

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

A power management chip can control the power-on sequence of devices.

Panel
For the front panel of the S2XF4A card, see Figure 6-18.

Figure 6-18 Front Panel of the S2XF4A Card

Interfaces
The S2XF4A card uses hot-swappable SFP+ optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-85.

Table 6-85 S2XF4A Card Interface Descriptions

Interface Description

10GBASE-SR (SFP+-300-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 850 nm,
maximum transmission distance: 300 m, with the
digital diagnosis function
Transmission power range: -7.3 dBm to -1 dBm,
receiving sensitivity: -11.1 dBm, overload
power: 0.5 dbm

10GBASE-LR (SFP+-S10K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1310 nm,
maximum transmission distance: 10 km, with the
digital diagnosis function
Transmission power range: -8.2 dBm to 0.5
dBm, receiving sensitivity: -10.3 dBm, overload
power: 0.5 dbm

10GBASE-ER&EW (SFP+-S40K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 40 km, with the
digital diagnosis function
Transmission power range: -4.7 dBm to 4 dBm,
receiving sensitivity: -14.1 dBm, overload
power: -1 dbm

6-72

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

10GBASE-ER&EW (SFP+-S80K-D) LC connector, connected with a single-mode


optical fiber, optical wavelength: 1550 nm,
maximum transmission distance: 80 km, with the
digital diagnosis function
Transmission power range: 0 dBm to 4 dBm,
receiving sensitivity: -24 dBm, overload power:
-7 dbm

For a description of the S2XF4A card interfaces, refer to Table 6-86.

Table 6-86 S2XF4A Card Interface Attributes

Attribute Specification

Connector Duplex LC.

Optical interface attribute Depends on the specific SFP+ optical module.

Operating mode Full duplex.

Standard IEEE 802.3ae 10GBASE-R.

Frame format Ethernet frame.

Network protocol Ethernet.

Indicators
There are four indicators on the front panel of the S2XF4A card, indicating the operation of
four optical interfaces respectively. For a description of these optical interface indicators,
refer to Table 6-87.

Table 6-87 S2XF4A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this interface.

Technical Parameters
For technical parameters of the S2XF4A card, refer to Table 6-88.

Table 6-88 S2XF4A Technical Parameters

Parameter Specification

Silk screen name S2XF4A

Dimensions 374.61 mm 395.4 mm 40.3 mm

Power consumption Full-load power consumption: 180 W

CPU Capacity Dual-core CPU, CPU speed: 800 MHz

6-73

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Parameter Specification

Memory Slot One DIMM slot

Maximum 4 GB
capacity

6.3.11 S1GT24A
Functions
The S1GT24A card provides 24 gigabit electrical interfaces, providing the 1000BASE-T
service. The S1GT24A card is applicable to all the ZXR10 8900E series switches and
supports MPLS line-speed access on gigabit interfaces.
The S1GT24A card provides the following functions:
l Data switching with a large capacity
The S1GT24A card provides 24 gigabit electrical interfaces, and supports MPLS
line-speed forwarding, 24-port POE and 24-port POE+.
l Gigabit out-of-band communication
This function is used for communication between the S1GT24A card and the CPU of
the card, and between the S1GT24A card and the main control card, for example,
downloading the CPU initialization information.

l EPLD online upgrade


The EPLD of the S1GT24A card provides the online upgrade function by simulating
the JTAG interface.

l JTAG test
The S1GF48A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.

l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.

l IPMC management and control unit


The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.

l Power supply management


A power management chip can control the power-on sequence of devices.

Panel
For the S1GT24A front panel, see Figure 6-19.

6-74

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Figure 6-19 S1GT24A Front Panel

Interfaces
The S1GT24A card uses RJ45 electrical interfaces for all the 24 ports. For a description
of these interfaces, refer to Table 6-89.

Table 6-89 S1GT24A Card Interface Descriptions

Interface Description

10/100/1000Base-T Complies with the IEEE 802.3z standard.


RJ45 connector.
Uses a Category 5 UTP cable.
Maximum transmission distance: 100 m.
MDI/MDIX.

Indicators
There are 24 indicators on the front panel of the S1GT24A card, indicating the operation
of 24 Ethernet electrical interfaces respectively. For a description of these interface
indicators, refer to Table 6-90.

Table 6-90 S1GT24A Interface Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this
interface.

Technical Parameters
For technical parameters of the S1GT24A card, refer to Table 6-91.

Table 6-91 S1GT24A Technical Parameters

Parameter Specification

Silk screen name S1GT24A

Dimensions 366.7 mm 338.8 mm 2.4 mm

Power consumption Static power consumption: 34.8


W
Power consumption when the
card is started but no network
cable is installed: 47.8W

6-75

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Parameter Specification

CPU Capacity Dual-core CPU, CPU speed:


800 MHz

Memory Maximum capacity 2 GB

6.3.12 S1GF24A
Functions
The S1GF24A card provides 24 gigabit optical interfaces for gigabit line-speed access.
The S1GF24A card is applicable to all the ZXR10 8900E series switches and supports the
Synchronous Ethernet function.
The S1GF24A card provides the following functions:
l Data switching with a large capacity
The S1GF24A card provides 24 gigabit SFP optical interfaces, and supports full
line-speed forwarding.
l Gigabit out-of-band communication
This function is used for communication between the S1GF24A card and the CPU of
the card, and between the S1GF24A card and the main control card, for example,
downloading the CPU initialization information.
l EPLD online upgrade
The EPLD of the S1GF24A card provides the online upgrade function by simulating
the JTAG interface.
l JTAG test
The S1GF24A card connects to main chips of line interface cards through a daisy
chain to conduct the JTAG test.
l Intelligent detection
The card provides temperature, voltage, and power consumption monitoring circuits
to implement real-time monitoring through the IIC bus.
l IPMC management and control unit
The IPMC of each line interface card connects to the IPMC of the MCS card through
a bus to establish an intelligent platform management system.
l Power supply management
A power management chip can control the power-on sequence of devices.

Panel
For the S1GF24A front panel, see Figure 6-20.

6-76

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Figure 6-20 S1GF24A Front Panel

Interfaces
The S1GF24A card uses hot-swappable SFP optical modules. Interface types are not
identified on the panel. For a description of the interfaces, refer to Table 6-92.

Table 6-92 S1GF24A Card Interface Descriptions

Interface Description

1000BASE-SX (SFP-M500) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission
distance: 500 m
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -18 dBm, overload power: 0 dBm

1000BASE-SX (SFP-M500-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 850 nm, maximum transmission
distance: 500 m, with the digital diagnosis function
Transmission power range: -9.5 dBm to -4 dBm, receiving
sensitivity: -17 dBm, overload power: 0 dBm

1000BASE-LX (SFP-S10K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km
Transmission power range: -9.5 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S10K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 10 km, with the digital diagnosis function
Transmission power range: -9 dBm to -3 dBm, receiving
sensitivity: -20 dBm, overload power: -3 dBm

1000BASE-LX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -4.5 dBm to 5 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -22 dBm, overload power: -3 dBm

6-77

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

1000BASE-LH (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 3 dBm, receiving
sensitivity: -22 dBm, overload power: -5 dBm

1000BASE-LH (SFP-S120K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 120 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -30 dBm, overload power: -9 dBm

100BASE-FX (SFP-M2K-D) LC connector, connected with a multi-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -10 dBm

LC connector, connected with a multi-mode optical fiber


, optical wavelength: 1310 nm, maximum transmission
distance: 2 km, with the digital diagnosis function
Transmission power range: -19 dBm to -14 dBm, receiving
sensitivity: -30 dBm, overload power: -14 dBm

100BASE-FX (SFP-S15K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S15K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 15 km, with the digital diagnosis function
Transmission power range: -8 dBm to -14 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

100BASE-FX (SFP-S40K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S40K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 40 km, with the digital diagnosis function
Transmission power range: -5 dBm to 0 dBm, receiving
sensitivity: -36 dBm, overload power: -10 dBm

6-78

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Interface Description

100BASE-FX (SFP-S80K) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -37 dBm, overload power: -8 dBm

100BASE-FX (SFP-S80K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: -5 dBm to 5 dBm, receiving
sensitivity: -37 dBm, overload power: -10 dBm

100BASE-FX (SFP-S100K-D) LC connector, connected with a single-mode optical fiber,


optical wavelength: 1310 nm, maximum transmission
distance: 80 km, with the digital diagnosis function
Transmission power range: 0 dBm to 5 dBm, receiving
sensitivity: -34 dBm

1.25G single-fiber and bidirectional SFP LC connector, connected with a single-mode optical fiber,
transmitting/receiving optical module optical wavelength: 1310 nm TX/1490 nm RX, maximum
(SFP-S10K-D-S) transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum
transmission distance: 10 km, with the digital diagnosis
function
Transmission power range: -9 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

1.25G single-fiber and bidirectional SFP LC connector, connected with a single-mode optical fiber,
transmitting/receiving optical module optical wavelength: 1310 nm TX/1490 nm RX, maximum
(SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1490 nm TX/1310 nm RX, maximum

6-79

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Interface Description

transmission distance: 40 km, with the digital diagnosis


function
Transmission power range: -3 dBm to 3 dBm, receiving
sensitivity: -19.5 dBm, overload power: -3 dBm

155M single-fiber and bidirectional SFP LC connector, connected with a single-mode optical fiber,
transmitting/receiving optical module optical wavelength: 1310 nm TX/1550 nm RX, maximum
(SFP-S15K-D-S) transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 15 km, with the digital diagnosis
function
Transmission power range: -14 dBm to -8 dBm, receiving
sensitivity: -31 dBm, overload power: -8 dBm

155M single-fiber and bidirectional SFP LC connector, connected with a single-mode optical fiber,
transmitting/receiving optical module optical wavelength: 1310 nm TX/1550 nm RX, maximum
(SFP-S40K-D-S) transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -3 dBm

LC connector, connected with a single-mode optical fiber,


optical wavelength: 1550 nm TX/1310 nm RX, maximum
transmission distance: 40 km, with the digital diagnosis
function
Transmission power range: -4 dBm to 0 dBm, receiving
sensitivity: -34 dBm, overload power: -10 dBm

For S1GF24A card interface attributes, refer to Table 6-93.

Table 6-93 S1GF24A Card Interface Attributes

Attribute Specification

Connector LC

Optical interface attribute Depending on the type of SFP module used

Operating mode Full duplex

Standard 10 G standard, and IEEE 802.3ae 10GBASE-R

Frame format Ethernet frame

Network protocol Ethernet

6-80

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 6 Cards

Indicators
There are 24 indicators on the front panel of the S1GF24A card, indicating the operation
of 24 Ethernet optical interfaces respectively. For a description of these optical interface
indicators, refer to Table 6-94.

Table 6-94 S1GF24A Card Interface Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through this
interface.

Technical Parameters
For technical parameters of the S1GF24A card, refer to Table 6-95.

Table 6-95 S1GF24A Technical Parameters

Parameter Specification

Silk screen name S1GF24A

Dimensions 374.61 mm 395.4 mm 40.3


mm

Power consumption Maximum power consumption:


41 W

CPU Capacity Dual-core CPU, CPU speed:


800 MHz

Memory Slot One SODIMM slot

Maximum capacity 1GB

6.4 Instructions on Card Usage


Users must pay attention to the following instructions:
1. The H2XF8D card is not applicable to the ZXR10 8902E switch or slots 512 of the
ZXR10 8912E switch.
2. The switching bandwidth of slots 512 of the ZXR10 8912E switch is 64 Gbps, and
only half-wire-speed is available. Packet forwarding among the S1XF12A cards on
slots 512 converges.
3. The H2XF8D, E1GF24A, and S2XF48A cards of the ZXR10 8900E have the largest
power consumption. The H2XF8D and E1GF24A cards have a power consumption
of nearly 140 W, and the S2XF48A card has a power consumption of nearly 200 W.
Users should focus on the power consumption and heat dissipation.

6-81

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

The heat dissipation at the first and last slots is worse than other slots. It is not
suggested to install the H2XF8D or E1GF24A card at the first or last slot.

6-82

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 7
Optical Modules
Overview
For the types of optical modules used by the line interface cards for the ZXR10 8900E
series switches, refer to Table 7-1.

Table 7-1 Types of Optical Modules

Type Example

Small Form-factor Pluggable (SFP)

Small Form-factor Pluggable Plus (SFP+)

Quad Small Form-factor Pluggable (QSFP)

C form-factor pluggable (CFP)

Indicators
An optical module has two indicators (ACT and LNK). For a description of the indicators,
refer to Table 7-2.

Table 7-2 Optical Module Indicator Descriptions

Indicator Color Description

Green Transmission status indicator of an optical port. When


ACT Green
data is being transmitted, this indicator flashes.

7-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Color Description

Physical connection status indicator of an optical port. If the


physical connection of the optical port is normal, this indicator
LNK Green
is lit. If the physical connection is abnormal or there is no
connection, the indicator is not lit.

SFP Attributes
For the attributes of the SFP optical module, refer to Table 7-3.

Table 7-3 SFP Attributes

MMF/500 M SMF/10 KM SMF/40 KM SMF/80 KM SMF/120


Attribute
Port Port Port Port KM Port

Transmission 500 m 10 km 40 km 80 km 120 km


distance

Central 850 nm 1310 nm 1310 nm/1550 1550 nm 1550 nm


wavelength nm

Minimum optical -9.5 dBm -11.5 dBm -11.5 dBm -11.5 dBm -11.5 dBm
power for
transmission

Maximum optical -4 dBm -3 dBm -3 dBm -3 dBm -3 dBm


power for
transmission

receiving <-19 dBm <-19 dBm <-19 dBm <-19 dBm <-19 dBm
sensitivity

Overload optical 0 dBm -3 dBm -3 dBm -3 dBm -3 dBm


power

Fiber type Multi mode Single mode Single mode Single mode Single mode

SFP+ Attributes
For the attributes of the SFP+ optical module, refer to Table 7-4.

Table 7-4 SFP+ Attributes

Attribute MMF/300 M Port SMF/10 KM Port SMF/40 KM Port SMF/80 KM Port

Transmission 0300 m 010 km 40 Km 80 Km


distance

Central 850 nm 1310 nm 1550 nm 1550 nm


wavelength

Minimum optical -7.3 dBm -8.2 dBm -4.7 dBm 0 dBm


power for
transmission

7-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Chapter 7 Optical Modules

Attribute MMF/300 M Port SMF/10 KM Port SMF/40 KM Port SMF/80 KM Port

Maximum optical -1.0 dBm 0.5 dBm 4 dBm 4 dBm


power for
transmission

Receiving <-9.9 dBm <-12.6 dBm -14.1 dBm -24 dBm


sensitivity

Overload optical 0.5 dBm 0.5 dBm -1 dBm -7 dBm


power

Fiber type Multi mode Single mode Single mode Single mode

QSFP Attributes
For the attributes of the QSFP optical module, refer to Table 7-5.

Table 7-5 QSFP Attributes

Attribute SMF/40 KM Port

Transmission distance 40 Km

Central wavelength 850 nm

Minimum optical power for transmission -7.6 dBm

Maximum optical power for transmission 2.4 dBm

Receiving sensitivity -5.4 dBm

Overload optical power 2.4 dBm

Fiber type MPO

CFP Attributes
For the attributes of the CFP optical module, refer to Table 7-6.

Table 7-6 CFP Attributes

Attribute SMF/40 KM Port

Transmission distance 40 Km

Central wavelength 1271nm, 1291nm, 1311nm, 1331nm

Minimum optical power for transmission 1 dBm

Maximum optical power for transmission 4 dBm

Receiving sensitivity -20 dBm

Overload optical power -5 dBm

Fiber type Single mode

7-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

7-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix A
Indicator Reference Table
Table of Contents
8912EMCS1D Indicators ........................................................................................ A-1
8908EMCS1D Indicators ........................................................................................ A-2
8905EMCS1D Indicators ........................................................................................ A-3
8902EMCS1D Indicators ........................................................................................ A-4
H2GF48D Indicators ............................................................................................... A-5
H2GF24D Indicators ............................................................................................... A-6
H2GT48D Indicators ............................................................................................... A-6
H2XF8D Indicators ................................................................................................. A-6
S1XF12A Indicators................................................................................................ A-6
S2LQ6L2A Indicators.............................................................................................. A-7
S2XF48A Indicators................................................................................................ A-7
S1GT48A Indicators ............................................................................................... A-7
S1GT24A Indicators ............................................................................................... A-8
S1GF48A Indicators ............................................................................................... A-8
S1GF24A Indicators ............................................................................................... A-8
Fan Module Indicators ............................................................................................ A-9

A.1 8912EMCS1D Indicators


For a description of the 8912EMCS1D indicators, refer to Table A-1.

Table A-1 8912EMCS1D Indicator Descriptions

Indicator Description

112 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

A-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

A.2 8908EMCS1D Indicators


For a description of the 8908EMCS1D indicators, refer to Table A-2.

Table A-2 8908EMCS1D Indicator Descriptions

Indicator Description

18 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

A-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix A Indicator Reference Table

Indicator Description

PWR13 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

A.3 8905EMCS1D Indicators


For a description of the 8905EMCS1D indicators, refer to Table A-3.

Table A-3 8905EMCS1D Indicator Descriptions

Indicator Description

15 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

A-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Indicator Description

PWR15 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

ACT (green) Flashing: Data is being sent or received.

LINK (green) Lit: A link is established.


Not lit: No link is established.

A.4 8902EMCS1D Indicators


For a description of the 8902EMCS1D indicators, refer to Table A-4.

Table A-4 8902EMCS1D Indicator Descriptions

Indicator Description

12 RUN Not lit: The corresponding line interface card is faulty or out of position.
(green) Flashing: The corresponding line interface card is operating normally.

ALM Not lit: The corresponding line interface card has no alarm or is out
(red) of position.
Lit: The corresponding line interface card has an alarm.

A-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix A Indicator Reference Table

Indicator Description

PWR12 RUN Not lit: The corresponding power module is faulty or the module is
(green) out of position.
Lit: The corresponding power module is operating normally.

ALM Not lit: The corresponding power module has no alarm or is out of
(red) position.
Lit: The corresponding power module has an alarm.

RUN RUN Not lit: The MCS module is faulty.


(green) Flashing: The MCS module is operating normally.

ALM Not lit: The MCS module has no alarm.


(red) Lit: The MCS module has an alarm.

MST RUN Lit: The module is in active status.


(green) Not lit: The module is in standby status.

ALM Lit: The active/standby status is abnormal.


(red) Not lit: The active/standby status is normal.

ACT (green) for the SD card Lit: An SD card is installed.


slot Not lit: No SD card is installed or the SD card is faulty.
Flashing: The SD card is being read or data is being written into the
SD card.

FAN R (green) Not lit: Power is not properly supplied to the fan subrack.
Lit: Power is properly supplied to the fan subrack.

A (red) Not lit: The fan subrack operates normally.


Lit: The fan subrack has an alarm.

A.5 H2GF48D Indicators


There are 48 indicators on the front panel of the H2GF48D card, indicating the operation
of the 48 optical interfaces respectively. For a description of these indicators, refer to Table
A-5.

Table A-5 H2GF48D Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

A.6 H2GF24D Indicators


There are 24 indicators on the front panel of the H2GF24D card, indicating the operation
of the 24 optical interfaces respectively. For a description of these indicators, refer to Table
A-6.

Table A-6 H2GF24D Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.7 H2GT48D Indicators


There are 48 LINK/ACT indicators on the front panel of the H2GT48D card, indicating the
operation of the 48 interfaces respectively. For a description of these indicators, refer to
Table A-7.

Table A-7 H2GT48D Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.8 H2XF8D Indicators


There are eight LINK/ACT indicators on the front panel of the H2XF8D card, indicating the
operation of the eight interfaces respectively. For a description of these indicators, refer
to Table A-8.

Table A-8 H2XF8D Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.9 S1XF12A Indicators


There are 12 LINK/ACT indicators on the front panel of the S1XF12A card, indicating the
operation of the 12 interfaces respectively. For a description of these indicators, refer to
Table A-9.

A-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix A Indicator Reference Table

Table A-9 S1XF12A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.10 S2LQ6L2A Indicators


There are eight LINK/ACT indicators on the front panel of the S2LQ6L2A card (six QSFP
interface indicators and two CFP interface indicators). For a description of these indicators,
refer to Table A-10.

Table A-10 S2LQ6L2A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.11 S2XF48A Indicators


There are 48 LINK/ACT indicators on the front panel of the S2XF48A card, indicating the
operation of the 12 interfaces respectively. For a description of these indicators, refer to
Table A-11.

Table A-11 S2XF48A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: No link is established.
Flashing: Data is being sent or received.

A.12 S1GT48A Indicators


There are 48 indicators on the front panel of the S1GT48A card, indicating the operation
of the 48 interfaces respectively. For a description of these indicators, refer to Table A-12.

A-7

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table A-12 S1GT48A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through
this interface.

A.13 S1GT24A Indicators


There are 24 indicators on the front panel of the S1GT24A card, indicating the operation
of the 24 interfaces respectively. For a description of these indicators, refer to Table A-13.

Table A-13 S1GT24A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through
this interface.

A.14 S1GF48A Indicators


There are 48 indicators on the front panel of the S1GF48A card, indicating the operation
of the 48 interfaces respectively. For a description of these indicators, refer to Table A-14.

Table A-14 S1GF48A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through
this interface.

A.15 S1GF24A Indicators


There are 24 indicators on the front panel of the S1GF24A card, indicating the operation
of the 24 interfaces respectively. For a description of these indicators, refer to Table A-15.

A-8

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix A Indicator Reference Table

Table A-15 S1GF24A Indicator Descriptions

Indicator Description

LINK/ACT Lit: A link is established.


Not lit: There is no connection with this interface.
Flashing: Data is being sent or received through
this interface.

A.16 Fan Module Indicators


There are two indicators on the fan subrack of the ZXR10 8912E/8908E/8905E switch.
For a description of these indicators, refer to Table A-16.

Table A-16 ZXR10 8912E/8908E/8905E Fan Module Indicator Descriptions

Indicator Description

RUN (green) Not lit: Power is not properly supplied to the fan subrack.
Lit: Power is properly supplied to the fan subrack.

ALM (red) Not lit: The fan subrack operates normally.


Lit: The fan subrack has an alarm.

There is no indicator on the ZXR10 8902E fan subrack. The fan operation is indicated by
the FAN indicator on the MCS module of the ZXR10 8902E switch.

A-9

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

A-10

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix B
Card Reference Table
Table of Contents
Card List................................................................................................................. B-1
Technical Specifications of the Cards...................................................................... B-2

B.1 Card List


For the cards that the ZXR10 8900E supports, refer to Table B-1.

Table B-1 Cards Supported by the ZXR10 8900E

Silk Screen Name Description

8912EMCS1D ZXR10 8912E main control and switching card with a clock
module

8908EMCS1D ZXR10 8908E main control and switching card with a clock
module

8905EMCS1D ZXR10 8905E main control and switching card with a clock
module

8902EMCS1D ZXR10 8902E main control and switching card with a clock
module

8902EMCS1A ZXR10 8902E main control and switching card without clock
module

8905EMCS1A ZXR10 8905E main control and switching card without clock
module

8908EMCS1A ZXR10 8908E main control and switching card without clock
module

8912EMCS1A ZXR10 8912E main control and switching card without clock
module

H2GF48D 48-port GE optical interface card with a clock module

H2GF24D 24-port GE optical interface card with a clock module

H2GT48D 48-port GE electrical interface card with a clock module

H2XF8D 8-port 10-GE optical interface card with a clock module

S1XF12A 12-port 10-GE optical interface card with a clock module,


which has no expansion slot

B-1

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Silk Screen Name Description

S2LQ6L2A 8-port 40-GE optical interface card with a clock module

S2XF48A 48-port 10-GE optical interface card with a clock module

S1GF48A 48-port GE optical interface card with a clock module

S1GT48A 48-port GE electrical interface card with a clock module

S2XF4A 4-port 10-GE optical interface card with a clock module

S1GT24A 24-port GE electrical interface card with a clock module

S1GF24A 24-port GE optical interface card with a clock module

B.2 Technical Specifications of the Cards


For the weights, power consumptions, and thermal loads of the ZXR10 8900E cards, refer
to Table B-2.

Table B-2 Technical Specifications of the ZXR10 8900E Cards

Silk Screen Name Weight Power Consumption Thermal Load (BTU/Hour)

8912EMCS1D 3.7 kg Static power consumption: Static thermal load: 158.09


about 56.5 W Thermal load after power-on:
Power consumption after 237.27
power-on: about 84.8 W Full wire-speed thermal load:
Full wire-speed power 321.21
consumption: 114.8 W

8908EMCS1D 3.7 kg Static power consumption: Static thermal load: 158.087


about 56.5 W Thermal load after power-on:
Power consumption after 237.27
power-on: about 84.8 W Full wire-speed thermal load:
Full wire-speed power 321.21
consumption: 114.8 W

8905EMCS1D 3.7 kg Static power consumption: Static thermal load: 158.087


about 56.5 W Thermal load after power-on:
Power consumption after 237.27
power-on: about 84.8 W Full wire-speed thermal load:
Full wire-speed power 321.21
consumption: 114.8 W

8902EMCS1D 1.5 kg Static power consumption: Static thermal load: 80.02


28.6 W Thermal load after power-on:
Full-load power 86.74
consumption: about 31
W

B-2

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix B Card Reference Table

Silk Screen Name Weight Power Consumption Thermal Load (BTU/Hour)

8902EMCS1A 1.3 kg Static power consumption: Static thermal load: 80.02


23.6 W Thermal load after power-on:
Full-load power 86.74
consumption: about 26
W

8905EMCS1A 2.8 kg Static power consumption: Static thermal load: 81.14


about 29 W Thermal load after power-on:
Power consumption after 145.5
power-on: about 52 W Full wire-speed thermal load:
Full wire-speed power 167.88
consumption: 60 W

8908EMCS1A 2.8 kg Static power consumption: Static thermal load: 81.14


about 29 W Thermal load after power-on:
Power consumption after 145.5
power-on: about 52 W Full wire-speed thermal load:
Full wire-speed power 167.88
consumption: 60 W

8912EMCS1A 3.5 kg Static power consumption: Static thermal load: 158.09


about 51.5 W Thermal load after power-on:
Power consumption after 237.27
power-on: about 79.8 W Full wire-speed thermal load:
Full wire-speed power 321.21
consumption: 109.8 W

H2GF48D 3.3 kg Static power consumption: Static thermal load: 112.48


about 40.2 W Thermal load after power-on:
Power consumption without 144.66
optical modules: 51.7 W Full wire-speed thermal load:
Full wire-speed power 296.59
consumption: 106.0 W

H2GF24D 3.2 kg Static power consumption: Static thermal load: 112.48


about 40.2 W Thermal load after power-on:
Power consumption without 144.66
optical modules: 51.7 W Full wire-speed thermal load:
Full wire-speed power 264.69
consumption: 94.6 W

B-3

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Silk Screen Name Weight Power Consumption Thermal Load (BTU/Hour)

H2GT48D 3.3 kg Static power consumption: Static thermal load: 138.50


about 49.5 W Thermal load after power-on:
Power consumption without 163.68
network cables installed: Full wire-speed thermal load:
58.5 W 297.15
Full wire-speed power
consumption: 106.2 W

H2XF8D 3.6 kg Static power consumption: Static thermal load: 198.66


about 71.0 W Thermal load after power-on:
Power consumption without 226.36
optical modules: 80.9 W Full wire-speed thermal load:
Full wire-speed power 399.0
consumption: 142.9 W

S1XF12A 3.0 kg Static power consumption: Static thermal load: 143.54


about 51.3 W Thermal load after power-on:
Power consumption without 169.84
optical modules: 60.7 W Full wire-speed thermal load:
Full wire-speed power 281.48
consumption: 100.6 W

S2LQ6L2A 3.9 kg Static power consumption: Static thermal load: 251.82


about 90 W Full wire-speed thermal load:
Full wire-speed power 335.76
consumption: 120 W

S2XF48A 3.9 kg Full wire-speed power Full wire-speed thermal load:


consumption: 197 W 551.22

S1GF48A 3.0 kg Static power consumption: Static thermal load: 75.54


about 27 W Full wire-speed thermal load:
Full wire-speed power 189.41
consumption: 67.7 W

S1GT48A 2.8 kg Static power consumption: Static thermal load: 105.76


about 37.8 W Thermal load after power-on:
Power consumption without 157.8
optical modules: 56.4 W Full wire-speed thermal load:
Full wire-speed power 167.88
consumption: 60 W

S2XF4A 3.4 kg Static power consumption: Static thermal load: 137.72


about 49.22 W Full wire-speed thermal load:
Full wire-speed power 154.17
consumption: 55.1 W

B-4

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Appendix B Card Reference Table

Silk Screen Name Weight Power Consumption Thermal Load (BTU/Hour)

S1GT24A 2.6 kg Static power consumption: Static thermal load: 97.44


about 34.8 W Thermal load after power-on:
Power consumption without 126
optical modules: 45 W Full wire-speed thermal load:
Full wire-speed power 133.84
consumption: 47.8 W

S1GF24A 2.9 kg Static power consumption: Static thermal load: 67.76


about 24.2 W Full wire-speed thermal load:
Full wire-speed power 114.8
consumption: 41 W

B-5

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

This page intentionally left blank.

B-6

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Figures
Figure 2-1 B6080-20 Cabinet.................................................................................... 2-2
Figure 2-2 Structure of the B6080-20 Cabinet ........................................................... 2-3
Figure 3-1 ZXR10 8912E Front Panel ....................................................................... 3-3
Figure 3-2 ZXR10 8908E Front Panel ....................................................................... 3-4
Figure 3-3 ZXR10 8905E Front Panel ....................................................................... 3-5
Figure 3-4 ZXR10 8902E (DC) Front Panel............................................................... 3-5
Figure 3-5 ZXR10 8902E (AC) Front Panel............................................................... 3-6
Figure 3-6 ZXR10 8912E Slot Layout........................................................................ 3-7
Figure 3-7 ZXR10 8908E Slot Layout........................................................................ 3-8
Figure 3-8 ZXR10 8905E Slot Layout........................................................................ 3-8
Figure 3-9 ZXR10 8902E Slot Layout........................................................................ 3-9
Figure 3-10 ZXR10 8912E/8908E/8905E Hardware Architecture ............................ 3-10
Figure 3-11 ZXR10 8902E Hardware Architecture................................................... 3-10
Figure 4-1 Front Panel of the ZXR10 8912E/8908E/8905E Power Supply
Module.................................................................................................... 4-1
Figure 4-2 Rear Panel of the ZXR10 8912E/8908E/8905E DC Power Supply
Module.................................................................................................... 4-2
Figure 4-3 Rear Panel of the ZXR10 8912E/8908E/8905E AC Power Supply
Module.................................................................................................... 4-3
Figure 4-4 Front Panel of the ZXR10 8902E DC Power Supply Module .................... 4-4
Figure 4-5 Front Panel of the ZXR10 8902E AC Power Supply Module .................... 4-5
Figure 5-1 ZXR10 8912E Fan Subrack ..................................................................... 5-1
Figure 5-2 ZXR10 8908E Fan Subrack ..................................................................... 5-2
Figure 5-3 ZXR10 8905E Fan Subrack ..................................................................... 5-2
Figure 5-4 ZXR10 8902E Fan Subrack ..................................................................... 5-2
Figure 5-5 ZXR10 8902E Air Filter ............................................................................ 5-3
Figure 5-6 ZXR10 8905E Air Filter ............................................................................ 5-4
Figure 5-7 ZXR10 8908E Air Filter ............................................................................ 5-4
Figure 5-8 ZXR10 8912E Air Filter ............................................................................ 5-5
Figure 6-1 8912EMCS1D Front Panel....................................................................... 6-3
Figure 6-2 8908EMCS1D Front Panel....................................................................... 6-8
Figure 6-3 8905EMCS1D Front Panel..................................................................... 6-12
Figure 6-4 8902EMCS1D Front Panel..................................................................... 6-17

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Figure 6-5 Front Panel of the 8902EMCS1A Card................................................... 6-22


Figure 6-6 Front Panel of the 8905EMCS1A Card................................................... 6-26
Figure 6-7 Front Panel of the 8908EMCS1A Card................................................... 6-30
Figure 6-8 Front Panel of the 8912EMCS1A Card................................................... 6-34
Figure 6-9 H2GF48D Front Panel ........................................................................... 6-38
Figure 6-10 H2GF24D Front Panel ......................................................................... 6-44
Figure 6-11 H2GT48D Front Panel.......................................................................... 6-50
Figure 6-12 H2XF8D Front Panel............................................................................ 6-52
Figure 6-13 S1XF12A Front Panel .......................................................................... 6-54
Figure 6-14 S2LQ6L2A Front Panel ........................................................................ 6-57
Figure 6-15 Front Panel of the S2XF48A Card........................................................ 6-60
Figure 6-16 Front Panel of the S1GF48A Card ....................................................... 6-63
Figure 6-17 Front Panel of the S1GT48A Card ....................................................... 6-70
Figure 6-18 Front Panel of the S2XF4A Card.......................................................... 6-72
Figure 6-19 S1GT24A Front Panel.......................................................................... 6-75
Figure 6-20 S1GF24A Front Panel.......................................................................... 6-77

II

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Tables
Table 2-1 Technical Parameters of the B608020 Cabinet ........................................ 2-3
Table 3-1 ZXR10 8900E Configuration.................................................................... 3-11
Table 3-2 ZXR10 8900E Physical Parameters......................................................... 3-12
Table 3-3 ZXR10 8900E Reliability Parameters....................................................... 3-13
Table 4-1 Technical Specifications of the ZXR10 8912E/8908E/8905E DC Power
Supply Module ......................................................................................... 4-2
Table 4-2 Technical Specifications of the ZXR10 8912E/8908E/8905E AC Power
Supply Module ......................................................................................... 4-3
Table 4-3 Technical Specifications of the ZXR10 8902E DC Power Supply
Module..................................................................................................... 4-4
Table 4-4 Technical Specifications of the ZXR10 8902E AC Power Supply
Module..................................................................................................... 4-5
Table 5-1 ZXR10 8912E/8908E/8905E Indicator Descriptions................................... 5-2
Table 5-2 Technical Specifications of Fan Subracks .................................................. 5-3
Table 6-1 Cards Supported by the ZXR10 8900E...................................................... 6-1
Table 6-2 Wiring Sequence of the Console Cable ..................................................... 6-3
Table 6-3 Wiring Sequence of the IPMC Cable ......................................................... 6-4
Table 6-4 Wiring Sequence of the PPS&TOD OUT Cable ......................................... 6-4
Table 6-5 Wiring Sequence of the PPS&TOD IN Cable ............................................. 6-5
Table 6-6 8912EMCS1D Indicator Descriptions......................................................... 6-5
Table 6-7 Button Descriptions ................................................................................... 6-6
Table 6-8 8912EMCS1D Technical Parameters......................................................... 6-6
Table 6-9 Wiring Sequence of the Console Cable ..................................................... 6-8
Table 6-10 Wiring Sequence of the IPMC Cable ....................................................... 6-9
Table 6-11 Wiring Sequence of the PPS&TOD OUT Cable ....................................... 6-9
Table 6-12 Wiring Sequence of the PPS&TOD IN Cable ........................................... 6-9
Table 6-13 8908EMCS1D Indicator Descriptions..................................................... 6-10
Table 6-14 Button Descriptions ............................................................................... 6-11
Table 6-15 8908EMCS1D Technical Parameters..................................................... 6-11
Table 6-16 Wiring Sequence of the Console Cable ................................................. 6-13
Table 6-17 Wiring Sequence of the IPMC Cable ..................................................... 6-13
Table 6-18 Wiring Sequence of the PPS&TOD OUT Cable ..................................... 6-14
Table 6-19 Wiring Sequence of the PPS&TOD IN Cable ......................................... 6-14

III

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 6-20 8905EMCS1D Indicator Descriptions..................................................... 6-15


Table 6-21 Button Descriptions ............................................................................... 6-15
Table 6-22 8905EMCS1D Technical Parameters..................................................... 6-16
Table 6-23 Wiring Sequence of the Console Cable ................................................. 6-18
Table 6-24 Wiring Sequence of the IPMC Cable ..................................................... 6-18
Table 6-25 Wiring Sequence of the PPS&TOD OUT Cable ..................................... 6-19
Table 6-26 Wiring Sequence of the PPS&TOD IN Cable ......................................... 6-19
Table 6-27 8902EMCS1D Indicator Descriptions..................................................... 6-19
Table 6-28 Button Descriptions ............................................................................... 6-20
Table 6-29 8902EMCS1D Technical Parameters..................................................... 6-21
Table 6-30 Wiring Sequence of the Console Cable ................................................. 6-22
Table 6-31 Wiring Sequence of the IPMC Cable ..................................................... 6-23
Table 6-32 8902EMCS1A Card Indicator Descriptions ............................................ 6-23
Table 6-33 Button Descriptions ............................................................................... 6-24
Table 6-34 8902EMCS1A Technical Parameters ..................................................... 6-24
Table 6-35 Wiring Sequence of the Console Cable ................................................. 6-26
Table 6-36 Wiring Sequence of the IPMC Cable ..................................................... 6-27
Table 6-37 8905EMCS1A Card Indicator Descriptions ............................................ 6-27
Table 6-38 Button Descriptions ............................................................................... 6-28
Table 6-39 8905EMCS1A Technical Parameters ..................................................... 6-29
Table 6-40 Wiring Sequence of the Console Cable ................................................. 6-30
Table 6-41 Wiring Sequence of the IPMC Cable ..................................................... 6-31
Table 6-42 8908EMCS1A Card Indicator Descriptions ............................................ 6-32
Table 6-43 Button Descriptions ............................................................................... 6-33
Table 6-44 8908EMCS1A Technical Parameters ..................................................... 6-33
Table 6-45 Wiring Sequence of the Console Cable ................................................. 6-35
Table 6-46 Wiring Sequence of the IPMC Cable ..................................................... 6-35
Table 6-47 8912EMCS1A Card Indicator Descriptions ............................................ 6-36
Table 6-48 Button Descriptions ............................................................................... 6-36
Table 6-49 8912EMCS1A Technical Parameters ..................................................... 6-37
Table 6-50 H2GF48D Card Interface Descriptions................................................... 6-39
Table 6-51 H2GF48D Card Interface Attributes ....................................................... 6-42
Table 6-52 H2GF48D Interface Indicator Descriptions............................................. 6-43
Table 6-53 H2GF48D Technical Parameters ........................................................... 6-43
Table 6-54 H2GF24D Card Interface Descriptions................................................... 6-44

IV

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Tables

Table 6-55 H2GF24D Card Interface Attributes ....................................................... 6-48


Table 6-56 H2GF24D Interface Indicator Descriptions............................................. 6-48
Table 6-57 H2GF24D Technical Parameters ........................................................... 6-49
Table 6-58 H2GT48D Card Interface Descriptions................................................... 6-50
Table 6-59 H2GT48D Interface Indicator Descriptions............................................. 6-50
Table 6-60 H2GT48D Technical Parameters ........................................................... 6-50
Table 6-61 H2XF8D Card Interface Descriptions ..................................................... 6-52
Table 6-62 H2XF8D Card Interface Attributes ......................................................... 6-52
Table 6-63 H2XF8D Interface Indicator Descriptions ............................................... 6-53
Table 6-64 H2XF8D Technical Parameters.............................................................. 6-53
Table 6-65 S1XF12A Card Interface Descriptions ................................................... 6-55
Table 6-66 S1XF12A Card Interface Attributes........................................................ 6-55
Table 6-67 S1XF12A Interface Indicator Descriptions ............................................. 6-56
Table 6-68 S1XF12A Technical Parameters ............................................................ 6-56
Table 6-69 S2LQ6L2A Card Interface Descriptions ................................................. 6-57
Table 6-70 S2LQ6L2A Card Interface Attributes...................................................... 6-58
Table 6-71 Optical Module Attributes....................................................................... 6-58
Table 6-72 S2LQ6L2A Interface Indicator Descriptions ........................................... 6-59
Table 6-73 S2LQ6L2A Technical Parameters .......................................................... 6-59
Table 6-74 S2XF48A Card Interface Descriptions ................................................... 6-60
Table 6-75 S2XF48A Card Interface Attributes........................................................ 6-61
Table 6-76 S2XF48A Interface Indicator Descriptions ............................................. 6-62
Table 6-77 S2XF48A Technical Parameters ............................................................ 6-62
Table 6-78 S1GF48A Card Interface Descriptions ................................................... 6-63
Table 6-79 S1GF48A Card Interface Attributes ....................................................... 6-68
Table 6-80 S1GF48A Interface Indicator Descriptions ............................................. 6-68
Table 6-81 S1GF48A Technical Parameters............................................................ 6-69
Table 6-82 S1GT48A Card Interface Descriptions ................................................... 6-70
Table 6-83 S1GT48A Interface Indicator Descriptions ............................................. 6-70
Table 6-84 S1GT48A Technical Parameters............................................................ 6-70
Table 6-85 S2XF4A Card Interface Descriptions ..................................................... 6-72
Table 6-86 S2XF4A Card Interface Attributes.......................................................... 6-73
Table 6-87 S2XF4A Interface Indicator Descriptions ............................................... 6-73
Table 6-88 S2XF4A Technical Parameters .............................................................. 6-73
Table 6-89 S1GT24A Card Interface Descriptions ................................................... 6-75

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


ZXR10 8900E Hardware Description

Table 6-90 S1GT24A Interface Indicator Descriptions ............................................. 6-75


Table 6-91 S1GT24A Technical Parameters............................................................ 6-75
Table 6-92 S1GF24A Card Interface Descriptions ................................................... 6-77
Table 6-93 S1GF24A Card Interface Attributes ....................................................... 6-80
Table 6-94 S1GF24A Card Interface Descriptions ................................................... 6-81
Table 6-95 S1GF24A Technical Parameters............................................................ 6-81
Table 7-1 Types of Optical Modules .......................................................................... 7-1
Table 7-2 Optical Module Indicator Descriptions........................................................ 7-1
Table 7-3 SFP Attributes ........................................................................................... 7-2
Table 7-4 SFP+ Attributes ......................................................................................... 7-2
Table 7-5 QSFP Attributes ........................................................................................ 7-3
Table 7-6 CFP Attributes........................................................................................... 7-3
Table A-1 8912EMCS1D Indicator Descriptions ........................................................A-1
Table A-2 8908EMCS1D Indicator Descriptions ........................................................A-2
Table A-3 8905EMCS1D Indicator Descriptions ........................................................A-3
Table A-4 8902EMCS1D Indicator Descriptions ........................................................A-4
Table A-5 H2GF48D Indicator Descriptions...............................................................A-5
Table A-6 H2GF24D Indicator Descriptions...............................................................A-6
Table A-7 H2GT48D Indicator Descriptions...............................................................A-6
Table A-8 H2XF8D Indicator Descriptions .................................................................A-6
Table A-9 S1XF12A Indicator Descriptions................................................................A-7
Table A-10 S2LQ6L2A Indicator Descriptions............................................................A-7
Table A-11 S2XF48A Indicator Descriptions ..............................................................A-7
Table A-12 S1GT48A Indicator Descriptions .............................................................A-8
Table A-13 S1GT24A Indicator Descriptions .............................................................A-8
Table A-14 S1GF48A Indicator Descriptions .............................................................A-8
Table A-15 S1GF24A Indicator Descriptions .............................................................A-9
Table A-16 ZXR10 8912E/8908E/8905E Fan Module Indicator Descriptions .............A-9
Table B-1 Cards Supported by the ZXR10 8900E .....................................................B-1
Table B-2 Technical Specifications of the ZXR10 8900E Cards .................................B-2

VI

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential


Glossary
ACL
- Access Control List
ASIC
- Application Specific Integrated Circuit
CFP
- C Form-factor Pluggable
DC
- Direct Current
GPS
- Global Positioning System
IEEE
- Institute of Electrical and Electronics Engineers
MAN
- Metropolitan Area Network
PPS
- Pulse Per Second

QoS
- Quality of Service

SFP
- Small Form-factor Pluggable
SFP+
- Small Form-factor Pluggable Plus
TOD
- Time of Day
UTP
- Unshielded Twisted Pair

VII

SJ-20121213142710-003|2013-06-24 (R1.0) ZTE Proprietary and Confidential