You are on page 1of 6

Alarm Types Narrow Bands

A2 - 8.2.4. BPFI Pomp PNV


P1/K10 -PNV POMP NIET-KOPP VERTIKAAL
14
Route Spectrum
30-jan-96 15:14:51
Imbalance
12 OVERALL= 13.52 V-DG
RMS = 13.46
LOAD = 100.0
RPM = 2987. (49.78 Hz)
10 Fault Limit
RMS Velocity in mm/Sec

8
Misalignment

6
Looseness

Bearing
2

0
Freq: 475.00
0 500 1000 1500 2000 2500 Ordr: 9.542
Frequency in Hz Spec: .06356
Label: BPFI with 1xrPM modulations.
Overall Vibration
The total vibration energy
measured within a specific
frequency range.

includes a combination of all


vibration signals within
measured frequency range
does not include vibration
signals outside measured
frequency range
produces a numerical value
Alarm Types Overall Alarm
Look to the global vibration level
A2 - 8.2.4. BPFI Pomp PNV
P1/K10 -PNV POMP NIET-KOPP VERTIKAAL
12
Route Spectrum
30-jan-96 15:14:51

OVERALL= 13.52 V-DG


RMS = 13.46
LOAD = 100.0
9 RPM = 2987. (49.78 Hz)
Fault Limit
RMS Velocity in mm/Sec

0
Freq: 1321.9
0 500 1000 1500 2000 2500 Ordr: 26.55
Frequency in Hz Spec: .119
Label: BPFI with 1xrPM modulations.
Analyse of data: Spectra,
Waveform and Trends
Vibration
-Imbalance
-Misalignment
-Looseness
-Bearing problems
-Belt problems
-Gear problems
-Lubrification
-Electrical problems
-Resonance
-Sleeve Bearing problems
-Other
Vibration analysis

"Of all the parameters that can be measured non


intrusively in industry today, the one containing the
most information is the vibration signature." Art
Crawford

Vibration Analysis is the foundation of a predictive


maintenance program