ANNEXURE - A

Observation Remarks
MB advised to replace the bed tubes from Enmas agreed to do the same at a later date.
plain bore to rifle bore tubes.

Boiler performance: Since the Superheater steam temperature


Jindal has two fuels for the steam generation, short fall is at 60% BMCR which may not be a
the Indian coal & the Imported coal. risk since operating the boiler at such low
The SH performance is short by 60C at control load will be a remote.
load (60% BMCR) while firing imported coal.

Coal Nozzle. Coal nozzle design is not as per MB


standards and the design of the same has
been modified by Enmas based on the Indian
industry experience.

Air nozzle design The criteria specified by MB is deviated and


hence there is a chance of back flow of solids
into the plenum chamber during very low load
operation. It is advisable to operate at high
excess air at part loads in order to avoid back
flow of solids.

Gas mass velocity through the Air heater Gas mass velocity is higher than MBs
tubes. recommendations which may lead to high
erosion on Airheater tubes particularly with
high ash Indian coals.

Bed drains location Arrangement of bed drains are not


symmetrical from the central line of the boiler,
. 8 nos. are provided on one side and 4 Nos.
on the other side. 4 Nos. drains on one side
may not be adequate. Enmas shall make
provision for future addition.

Superheater metal temperature calculations The primary Superheater outlet legs have
been modified from SA 213 T11 to SA 213
T22 as per our advise.