You are on page 1of 164

3

Siemens AG 2016

HMI Software

3/2 Introduction 3/79 SCADA system SIMATIC WinCC V7


3/79 Introduction
3/5 HMI Software in the TIA Portal
3/80 SIMATIC WinCC V7
3/5 Introduction
3/101 SIMATIC WinCC options
3/6 SIMATIC WinCC (TIA Portal) Engineering
3/102 SIMATIC Information Server
3/12 SIMATIC WinCC (TIA Portal) Runtime
3/105 SIMATIC Process Historian
3/13 WinCC Runtime Advanced
3/107 WinCC/Calendar Scheduler
3/18 WinCC Runtime Professional
3/108 WinCC/ChangeControl & WinCC/Audit
3/23 WinCC Runtime Communication 3/110 WinCC/Connectivity Pack &
3/28 SIMATIC WinCC (TIA Portal) options WinCC Connectivity Station
3/30 WinCC Recipes 3/112 WinCC/DataMonitor
3/32 WinCC Logging 3/115 WinCC/Event Notifier
3/34 WinCC Audit 3/116 WinCC/IndustrialDataBridge
3/35 SIMATIC Logon 3/119 WinCC/Open Development Kit (ODK)
3/37 WinCC Sm@rtServer 3/120 WinCC/PerformanceMonitor
3/41 WinCC Server / WinCC Client 3/123 WinCC/Redundancy
3/43 WinCC Redundancy
3/124 WinCC/SES
3/44 WinCC WebNavigator
(Sequence Execution System)
3/48 WinCC DataMonitor
3/125 WinCC/Server
3/51 WinCC ControlDevelopment
3/127 WinCC/TeleControl
3/52 Software for energy management 3/132 WinCC/User Archives
3/52 SIMATIC B.Data 3/133 WinCC/WebNavigator
3/56 SIMATIC powerrate 3/137 WinCC/WebUX

3/59 SIMATIC WinCC flexible HMI system 3/139 WinCC add-ons and
3/59 SIMATIC WinCC flexible ES partner management
3/63 SIMATIC WinCC flexible RT 3/139 Introduction
3/69 SIMATIC WinCC flexible options 3/141 SCADA System
3/70 WinCC flexible /ChangeControl SIMATIC WinCC Open Architecture
3/71 WinCC flexible /Archives 3/141 SIMATIC WinCC Open Architecture V3.14
3/72 WinCC flexible /Recipes 3/154 SIMATIC WinCC Open Architecture
3/73 WinCC flexible /Audit
Add-ons
3/74 SIMATIC Logon for WinCC flexible
3/75 WinCC flexible /Sm@rtAccess 3/160 SIMATIC ProAgent
3/76 WinCC flexible /Sm@rtService process diagnostics software
3/77 WinCC flexible /OPC-Server 3/160 SIMATIC ProAgent
3/78 WinCC flexible /ProAgent

Siemens ST 80 / ST PC 2016
Siemens AG 2016

HMI Software

Introduction

Overview
SIMATIC HMI Efficient to a new level SIMATIC WinCC (TIA Portal)
Creation of applications in the machine-level area and of
Innovative, efficient, scalable and open software for the process visualization or SCADA systems
machine-level area and for SCADA solutions.
SIMATIC WinCC flexible
With the SIMATIC WinCC (TIA Portal), SIMATIC WinCC and Maintenance of visualization solutions in the machine-level
SIMATIC WinCC Open Architecture product families, area:
SIMATIC HMI offers visualization and configuration software for
the entire HMI spectrum, from the machine-level area right up to SCADA system SIMATIC WinCC
SCADA systems: Creation of process visualization or SCADA systems
SCADA system SIMATIC WinCC Open Architecture
Creation of applications with a high demand for customer-
specific adaptations, large and/or complex applications, as
well as projects that demand special system requirements
and functions.
SIMATIC WinCC (TIA Portal)

3
WinCC Professional
Engineering
software

WinCC Advanced

WinCC Comfort

WinCC Basic

Basic Panels Comfort Panels PC-based single-user PC-based multi-user systems


Mobile Panels systems, SCADA functionality
x77 Panels and e.g. SIMATIC IPC
Multi Panels
Integrated runtime Integrated runtime WinCC Runtime WinCC Runtime Professional
and target sytems
Runtime software

module module Advanced

G_ST80_XX_00461
WinCC (TIA Portal) is based on the central engineering In addition, WinCC (TIA Portal) offers:
framework Totally Integrated Automation Portal (TIA Portal) Intuitive user interface with maximum degree of operator
which offers users a niform, efficient and intuitive solution to all friendliness
their automation tasks. SIMATIC WinCC (TIA Portal) covers
applications in the machine-level area and applications in the Clear configuration of devices and network topologies
process visualization or SCADA environment. WinCC Shared data management and uniform symbols via controller
(TIA Portal) offers the uniform and scalable configuration tools and HMI
WinCC Basic, Comfort, Advanced and Professional for Optimum interaction with the controller and HMI in a working
configuring the current SIMATIC HMI devices: environment
SIMATIC Basic Panels Powerful editors for efficient engineering
SIMATIC Comfort Panels Integrated mass data operations for efficient configuration
SIMATIC Mobile Panels System diagnostics as an integral component
PC-based systems for the machine-level area Comprehensive library concept
- SIMATIC WinCC Runtime Advanced
- SIMATIC WinCC Runtime Professional

3/2 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software

Introduction

Overview (continued)
SIMATIC SCADA systems
The data volume in modern industrial plants is growing continu-
ously and along with it the challenges faced by the SCADA
solutions used: Enormous data volumes must be administered
and archived for the long term. This is accompanied by increas-
ing demands on performance. Technologies, including some
from the consumer environment, are finding their way into indus-
try. Globalization calls for higher-level SCADA systems that can
be used worldwide and the need for mobile access to plant
information is also growing. On top of all these requirements in
these times of ever increasing (energy) costs is the need to
improve energy efficiency and productivity.
With SIMATIC SCADA systems, you are fit for the future
Efficiency
Efficiency: As a key to greater productivity, SIMATIC SCADA
systems combine efficient engineering with high-performance 3
archiving and maximum data security. These features provide
the basis for efficient operations management and intelligent http://www.siemens.com/scada
production analyses.
SCADA system SIMATIC WinCC V7
Scalability
The process visualization or SCADA system for visualizing and
We offer stationary and mobile solutions to cover increasing operating processes, production flows, machines and plants in
demands security guaranteed. In this area, we apply more all sectors from the simple single-user station through to
than 15 years of SCADA know-how from all industry sectors. distributed multi-user systems with redundant servers and
No matter how large or small your request is we have the right cross-location solutions with web clients. WinCC is the informa-
answer. tion hub for company-wide, vertical integration (process visual-
Innovation ization and platform for IT & business integration).
Stay informed with mobile SCADA solutions anywhere and at All HMI functions on-board with industry-standard functions
any time including with existing tablet and smartphone hard- for signaling and acknowledging events, archiving of
ware. The use of multi-touch gestures in the industrial environ- messages and measured values, logging of all process and
ment opens the door for modern operating concepts. configuration data, user administration and visualization
(WinCC basic software).
Openness Company-wide, flexible client/server structures with operator
Due to the support of international standards and system-inter- stations on the Web, distributed servers and data integrity
nal script and programming interfaces, special requests can thanks to redundancy
also be easily implemented. Easy to integrate over standard interfaces such as OPC (OLE
for Process Control), WinCC OLE-DB, VBA (Visual Basic for
Applications), VB script, C-API (ODK)
Integration platform in the company thanks to the Historian
functionality integrated into WinCC based on the Microsoft
SQL Server, standard and programming interfaces and tools
and clients for evaluation
Modular expansion with options and add-ons as well as
individual functional expansions with VB Script, Visual Basic
for Applications, C-API (ODK) and integration of ActiveX
elements.
SIMATIC SCADA and SIMATIC IPCs
Perfect interaction for optimum productivity.
Price advantage as "Package" comprising hardware and
software
System-tested solutions reduce testing overhead
Simple ordering and synchronized logistics
Only if ordered together with the SIMATIC IPC.
http://www.siemens.com/scada-ipc

Siemens ST 80 / ST PC 2016 3/3


Siemens AG 2016

HMI Software

Introduction

Overview (continued)
SCADA system SIMATIC WinCC Open Architecture PC-based HMI solutions (machine-level / SCADA)
with SIMATIC industrial PCs
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific Our reliable and innovative SIMATIC IPC industrial PCs are the
adaptations, large and/or complex applications, as well as optimal PC hardware platforms. SIMATIC industrial PCs are
projects that demand special system requirements and offered with low-cost software packages. For runtime versions
functions. with SIMATIC WinCC V7, WinCC Runtime Professional or WinCC
Runtime Advanced visualization software products, as well as
SIMATIC WinCC Open Architecture demonstrates its high the SIMATIC WinAC RTX (F) software controller. The simultane-
performance in networked and redundant high-end control ous purchase of industrial PC and software package results in a
systems in particular. From the field level to the control station, price advantage.
from the machine to the company headquarters integrated,
high-performance communication is ensured. In every situation, http://www.siemens.com/pc-based
a high level of availability, reliable information, fast interaction
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium.

3 With its disaster recovery system and SIL3 certification,


SIMATIC WinCC Open Architecture demonstrates its reliability in
a wide range of critical applications. SIMATIC WinCC Open
Architecture can be used on any platform and is available for
Windows, Linux, iOS and Android.
SIMATIC WinCC Open Architecture is open for independent
in-house developments, which means that ideas can be turned
into new applications quickly and easily.
Object-orientation supports efficient engineering and flexible
plant expansion
For large, distributed systems with up to 2048 servers
Scalable from a small single-user system up to a networked,
redundant high-end system
WinCC OA can be used on any platform and is available for
Windows, Linux, iOS and Android
Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
WinCC OA offers a platform for customer-specific solutions
Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements

3/4 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
Introduction

Overview
SIMATIC WinCC Runtime Advanced visualization software
PC-based HMI solution for single-user systems directly at the
machine
Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
Basic package expandable by means of option packages
Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
Can be integrated into automation solutions based on TCP/IP
networks
Expanded service concepts with remote operation,
diagnostics and administration over the Intranet and Internet
in combination with email communication

SIMATIC WinCC Runtime Professional visualization software 3


PC-based operator control and monitoring system for visual-
ization and operator control of processes, production flows,
SIMATIC WinCC (TIA Portal) engineering software machines and plants in all sectors from the simple single-
Family of configuration systems with WinCC Basic, Comfort, user station through to distributed multi-user systems and
Advanced and Professional for SIMATIC operator panels, as well cross-location solutions with web clients. WinCC Runtime
as for the PC-based visualization systems WinCC Runtime Professional is the information hub for corporation-wide
Advanced and WinCC Runtime Professional vertical integration.
Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
Basic package expandable by means of option packages
Also included are APIs for the Runtime to utilize the open
programming interfaces
Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment

Siemens ST 80 / ST PC 2016 3/5


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Overview Application
Integrated family of engineering tools for configuring SIMATIC SIMATIC WinCC in the editions Basic, Comfort, Advanced and
HMI operator panels, as well as for the PC-based visualization Professional are innovative engineering tools for configuring
systems WinCC Runtime Advanced and WinCC Runtime SIMATIC HMI operator panels, as well as for the PC-based
Professional. visualization systems WinCC Runtime Advanced and WinCC
WinCC (TIA Portal) is based on the new central engineering Runtime Professional.
framework Totally Integrated Automation Portal (TIA Portal), Depending on the selected product, various target systems can
which offers the user a uniform, efficient and intuitive solution be configured:
to all automation tasks.
WinCC (TIA Portal) also offers uniform engineering from the WinCC Basic
Basic Panel through to SCADA applications. Basic Panels (1st Generation)
Together with the STEP 7 (TIA Portal) products, WinCC Basic Panels (2nd Generation)
(TIA Portal) forms the optimum solution for integrated, efficient
engineering. WinCC Comfort

Current version: As WinCC Basic, plus:


Comfort Panels
3
SIMATIC WinCC Basic V13 SP1
SIMATIC WinCC Comfort V13 SP1 Mobile Panels 2nd Generation
SIMATIC WinCC Advanced V13 SP1 Mobile Panels of the x77 series
SIMATIC WinCC Professional V13 SP1 Panels of the 77 series
- Panels/Multi Panels of the 177 series
- Panels/Multi Panels of the 277 series
Benefits - Multi Panels of the 377 series
The integrated configuration software reduces training, WinCC Advanced
maintenance and service overhead and protects the
customer's investments. As WinCC Comfort, plus:
Minimized engineering overhead and reduction of lifecycle SIMATIC PCs with WinCC Runtime Advanced:
costs thanks to Totally Integrated Automation (TIA) - SIMATIC Rack PC:
- IPC547B, IPC547C, IPC547D, IPC547E
Minimized configuration overhead due to reuse of scalable
- IPC647B, IPC647C, IPC647D
and dynamizable objects
- IPC847B, IPC847C, IPC847D
Intelligent tools for efficient and simple configuration: - SIMATIC Box PC
- Wizard for defining the basic structure of the HMI project - IPC227D, IPC227E
- Table-based editors simplify the generation and processing - IPC427B, IPC427C, IPC427D
of similar types of object, e.g. for tags, texts, or alarms. - IPC627B, IPC627C, IPC627D
- Complex configuration tasks such as the definition of paths - IPC827B, IPC827C, IPC827D
of motion or the creation of the fundamental operator - SIMATIC Panel PC
prompting are simplified by means of graphical configu- - IPC277D, IPC277E
ration. - IPC477B, IPC477C, IPC477D
Comprehensive support of multi-language configurations for - IPC577B, IPC577C
worldwide use - IPC677B, IPC677C, IPC677D
- Selectable views for entering configuration data in several - SIMATIC modular Embedded Controller: EC31
languages - SIMATIC S7 Open Controller: ET 200SP Open Controller
- System and user-specific text lexicons - Industrial Flat Panel (Multi-Touch)
- Export/import of language-dependent texts Standard PC with WinCC Runtime Advanced
Investment protection due to SINUMERIK PC: PCU 50.3, PCU 50.5
- Import of the configuration from WinCC flexible 2008 SP2
and 2008 SP3 WinCC Professional
- Transfer of the configuration from WinCC V7.2 As WinCC Advanced, plus:
SIMATIC PCs with WinCC Runtime Professional:
- SIMATIC Rack PC
- Rack PC 547B, IPC547C, IPC547D, IPC547E
- Rack PC 647B, IPC647C, IPC647D
- Rack PC 847B, IPC847C, IPC847D
- SIMATIC Box PC
- Box PC 427B, IPC427C, IPC427D,
- Box PC 627B, IPC627C, IPC627D,
- Box PC 827B, IPC827C, IPC827D
- SIMATIC Panel PC
- IPC477C, IPC477D
- Panel PC 577B, IPC577C
- Panel PC 677B, IPC677C, IPC677D
- Industrial Flat Panel (Multi-Touch)
Standard PC with WinCC Runtime Professional

3/6 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Design Screen editor with comprehensive options for efficient and


fast screen configuration
The functionalities of the engineering tools of the SIMATIC Generation of interconnected screen objects via Drag&Drop,
WinCC family are based on each other. The available editors e.g. tags for the creation of input/output fields with process
are largely determined by the respective configurable target interfacing or buttons with screen selection function
systems and their function. A more comprehensive engineering Definition of screen templates and functions
tool such as WinCC Advanced can always be used to configure (comparable with the Slide Master in MS PowerPoint)
lower-level target devices as well (e.g. Basic Panels)
User-friendly editor for the creation of faceplates with defined
A Powerpack can be used to upgrade from a smaller edition to external interface from screen objects
a larger one. This does not apply to WinCC Basic.
Graphics-based configuration of motion paths
The functionality of WinCC engineering tools already contains Layer technology with up to 32 layers
the configuration support of the available Runtime options for
SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime Tools for the Align, Rotate and Mirror functions
Professional, irrespective of the purchased RT licenses. A sepa- Import/export
rate license is required for the target system when using the con-
figured Runtime options. of tags, links, text lists, and alarms
Tabular editors
Function Quick and easy generation and modification of configuration
objects of the same type, e.g. tags, texts or messages, in
3
Integration into automation systems tabular editors
Integration into the SIMATIC Totally Integrated Automation Portal Intelligent default settings depending on previously
(TIA Portal) configured data, e.g. automatic incrementing of addresses
Shared data management and uniform symbols via the when generating consecutive tags
controller and HMI Simple access to the properties of an object without super-
Optimum interaction between the controller and HMI in a fluous user intervention
working environment Simultaneous modification of common object properties
System diagnostics as an integral component
Object-based data management with user-friendly search
Shared use of communication settings and process point and edit options
definitions
Configuration of alarms and logs directly on the HMI tag, no
Simple dragging and dropping of tags from STEP 7 to an HMI switching between different editors
device, e.g. onto a screen
Cross-reference list with direct access to all objects, e.g. for
Excellent support for the new SIMATIC S7-1500 controller editing or selection
- With symbolic addressing
Search for objects in entire project
- Access to the new memory-optimized data blocks
- New alarm and diagnostics concept Text search and replace functions
Configuration interface Project documentation
Intuitive user interfaces with maximum degree of user friend- Selective project documentation, the following contents can
liness be printed:
- An entire project
Comprehensive and fast access to editors and project data
- One or more project-associated devices
Adaptive user interface of engineering tools depending on - Contents of an editor
configured target system - Libraries
User-definable user interface settings, e.g. layout, toolbars
Integrated mass data operations for efficient configuration
Project handling
Device-independent configuration data can be used on a
variety of target systems without the need for conversion. The
interface adapts itself to the functional possibilities of the
target device.
Cross-device utilization of common configuration data
(e.g. alarm classes, text library) in multi-device projects
Wizard-assisted definition of basic structure of HMI projects
(e.g. display layout, operator prompting)

Siemens ST 80 / ST PC 2016 3/7


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Function (continued)
Libraries for predefined/user-defined configuration objects System prerequisites
Storage of all configuration objects in the library, e.g. blocks WinCC engineering software
and even entire screens or tags
Faceplates can be constructed from simple screen objects on Processor type Core i5; 3.3 GHz or comparable
a customer-specific or project-specific basis. Changes to (recommended)
these faceplates can be made centrally (block definition).
RAM (recommended) 8 GB
A large number of scalable and dynamizable screen objects
Free hard disk space 2 GB on system drive "C:"
is included in the scope of delivery
Operating systems 32-bit operating systems
Size-scalable graphics for industrial applications are included Windows 7 Home Premium SP1
in the scope of delivery (only WinCC Basic)
Preview function for library objects Windows 7 Professional SP1
Windows 7 Enterprise SP1
Language support Windows 7 Ultimate SP1
64-bit operating systems
Multilingual project creation (max. 32 languages) in editors Windows 7 Home Premium SP1
thanks to selectable views
3
(only WinCC Basic)
Central management of language-specific texts and graphics Windows 7 Professional SP1
Windows 7 Enterprise SP1
in libraries Windows 7 Ultimate SP1
Edit, export and import of texts for translation Windows 8.1 (only WinCC Basic)
Windows 8.1 Professional
Language-specific graphics Windows 8.1 Enterprise
Windows Server 2008 R2 StdE SP1
Visual Basic and C-Script Support (not WinCC Basic)
IntelliSense function for fast programming of access to Windows Server 2012 R2 StdE
runtime objects Screen resolution 1920 x 1080 recommended
Simple creation of control sequences in script code Optical drive DVD-ROM
Visual Basic Script debugging in simulator and WinCC Note:
Runtime Advanced and WinCC Runtime Professional
Opening several instances of WinCC on your engineering PC at
Test and commissioning support the same time may result in more demanding hardware require-
Simulation of HMI projects on engineering PC ments.
Marking of incomplete or incorrect configuration directly in the In addition to WinCC, Windows also requires space on the hard
respective editor disk; e.g. free disk space should be available for the swap file.
Jump to error cause based on alarm messages in the The following formula has proven itself in the past: Size of swap
Compiler file = 3 x size of RAM. For further information, refer to your
Windows documentation
Migration of existing HMI projects
Data transfer in projects from WinCC flexible
Data transfer in projects from WinCC

3/8 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Ordering data Article No. Article No.

SIMATIC WinCC Basic V13 SP1 SIMATIC WinCC Professional V13


Engineering software for the SP1
configuration and simulation of Engineering software for the
Basic Panels; configuration and simulation of
electronic documentation in SIMATIC Panels;
English, German, French, Italian, SIMATIC WinCC Runtime Advanced
Spanish, Chinese and Runtime Professional;
Software and documentation on 6AV2100-0AA03-0AA5 electronic documentation in
DVD, floating license, English, German, French, Italian,
license key on USB stick Spanish, Chinese
as download 1) 6AV2100-0AA03-0AH5 SIMATIC WinCC Professional
software and license key (with a maximum of 512 PowerTags)
download, floating license, Software and documentation 6AV2103-0DA03-0AA5
email address required for the on DVD,
delivery floating license,
SIMATIC WinCC Comfort V13 SP1 license key on USB stick
Engineering software for the as download 1) 6AV2103-0DA03-0AH5
floating license, license key
3
configuration and simulation of
SIMATIC Panels; download,
electronic documentation in email address required for the
English, French, German, Italian, delivery
Spanish, simplified Chinese, SIMATIC WinCC Professional (with
traditional Chinese a maximum of 4 096 PowerTags)
Software and documentation on 6AV2101-0AA03-0AA5 Software and documentation on 6AV2103-0HA03-0AA5
DVD, DVD,
floating license, license key on floating license,
USB stick license key on USB stick
as download 1) 6AV2101-0AA03-0AH5 as download 1) 6AV2103-0HA03-0AH5
software and license key floating license,
download, floating license, license key download,
email address required for the email address required for the
delivery delivery
SIMATIC WinCC Advanced V13 SIMATIC WinCC Professional
SP1 max. PowerTags
Engineering software for the (unlimited PowerTags)
configuration and simulation of Software and documentation on 6AV2103-0XA03-0AA5
SIMATIC Panels; SIMATIC WinCC DVD,
Runtime Advanced floating license,
electronic documentation in license key on USB stick
English, German, French, Italian, as download 1) 6AV2103-0XA03-0AH5
Spanish, Chinese floating license,
Software and documentation on 6AV2102-0AA03-0AA5 license key download,
DVD, floating license, license key email address required for the
on USB stick delivery
as download 1) 6AV2102-0AA03-0AH5 SIMATIC WinCC V13 SP1
floating license, software and Engineering
license key download, Trial Licenses
email address required for the
delivery on DVD, 21 day trial
SIMATIC WinCC Basic 6AV2100-0AA03-0AA7
SIMATIC WinCC 6AV2102-0AA03-0AA7
Comfort/Advanced
SIMATIC WinCC Professional 6AV2103-0AA03-0AA7

1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC 2016 3/9


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Ordering data Article No. Article No.


Powerpacks Software Update Service
SIMATIC WinCC V13 Engineering For a period of 12 months and for a
Powerpacks fixed price, the customer is
(without version change) automatically provided with all
upgrades and service packs for
Floating license, each installed WinCC engineering
license key only on USB stick system or option. The contract is
SIMATIC WinCC Basic to 6AV2101-2AA03-0AC5 automatically extended by a further
SIMATIC WinCC Comfort 2) year unless canceled at least
SIMATIC WinCC Comfort to 6AV2102-2AA03-0BD5 12 weeks prior to expiration.
SIMATIC WinCC Advanced
Software Update Service
SIMATIC WinCC Advanced to 6AV2103-2AD03-0AC5 (Standard Edition)
SIMATIC WinCC Professional
512 PowerTags The delivery is implemented
SIMATIC WinCC Professional 6AV2103-2DH03-0BD5 according to the number of ordered
Powerpack 512 PowerTags to SUS products
4 096 PowerTags (e.g. 10 upgrade packages with
10 DVDs, 10 USB flash drives, etc.)
SIMATIC WinCC Professional 6AV2103-2HX03-0BD5

3
Powerpack 4 096 PowerTags to SIMATIC WinCC Comfort 6AV6612-0AA00-0AL0
max. PowerTags SIMATIC WinCC Advanced 6AV6613-0AA00-0AL0
as download 1) SIMATIC WinCC Professional 6AV2103-0DA00-0AL0
floating license, license key 512 PowerTags
download only, SIMATIC WinCC Professional 6AV2103-0HA00-0AL0
email address required for the 4 096 PowerTags
delivery SIMATIC WinCC Professional 6AV2103-0XA00-0AL0
SIMATIC WinCC Basic to 6AV2101-2AA03-0BJ5 max. PowerTags
SIMATIC WinCC Comfort 2) Software Update Service
SIMATIC WinCC Comfort to 6AV2102-2AA03-0BJ5 (Compact Edition)
SIMATIC WinCC Advanced
SIMATIC WinCC Advanced to 6AV2103-2AD03-0BJ5 The delivery items are combined.
SIMATIC WinCC Professional For several contracts, only 1 pack-
512 PowerTags age with 1 data medium set, 1 USB
flash drive with the corresponding
SIMATIC WinCC Professional 6AV2103-2DH03-0BJ5 number of licenses and the corre-
Powerpack 512 PowerTags to sponding number of CoLs will be
4 096 PowerTags supplied.
SIMATIC WinCC Professional 6AV2103-2HX03-0BJ5
Powerpack 4 096 PowerTags to Delivery items to be combined must
max. PowerTags be ordered as one item.
SIMATIC WinCC Comfort 6AV6612-0AA00-0AM0
SIMATIC WinCC Advanced 6AV6613-0AA00-0AM0
SIMATIC WinCC Professional 6AV2103-0DA00-0AM0
512 PowerTags
SIMATIC WinCC Professional 6AV2103-0HA00-0AM0
4 096 PowerTags
SIMATIC WinCC Professional 6AV2103-0XA00-0AM0
max. PowerTags
Software Update Service
(download) 1)
email address required for the
delivery
SIMATIC WinCC Comfort 6AV6612-0AA00-0AY0
SIMATIC WinCC Advanced 6AV6613-0AA00-0AY0
SIMATIC WinCC Professional 6AV2103-0DA00-0AY0
512 PowerTags
SIMATIC WinCC Professional 6AV2103-0HA00-0AY0
4 096 PowerTags
SIMATIC WinCC Professional 6AV2103-0XA00-0AY0
max. PowerTags
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
2)
valid only for Article No.'s 6AV2100-0AA03-0AA5 and
6AV2100-0AA03-0AH5

3/10 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

Ordering data Article No. Article No.


SIMATIC WinCC Engineering WinCC V7.0 / V7.2 RC -> WinCC
Upgrades Professional V13 SP1 and
WinCC Runtime Professional V13
WinCC V11..V12 -> WinCC V13 SP1 (continued)
SP1
SIMATIC WinCC RC 2 048 6AV2103-4FH03-0AE5
Software and documentation -> WinCC Professional
on DVD, 4 096 PowerTags and WinCC RT
upgrade license, Professional 2 048 PowerTags
license key on USB stick
SIMATIC WinCC V7.0 RC 8 192 6AV2103-4KX03-0AE5
SIMATIC WinCC Basic 6AV2100-3AA03-0AE5 -> WinCC Professional max.
SIMATIC WinCC Comfort 6AV2101-3AA03-0AE5 PowerTags and WinCC RT
SIMATIC WinCC Advanced 6AV2102-3AA03-0AE5 Professional 8 192 PowerTags
SIMATIC WinCC Professional 6AV2103-3DA03-0AE5 SIMATIC WinCC 65 536 6AV2103-4MX03-0AE5
512 PowerTags -> WinCC Professional max.
SIMATIC WinCC Professional 6AV2103-3HA03-0AE5 PowerTags and WinCC RT
4 096 PowerTags Professional 65 536 PowerTags
SIMATIC WinCC Professional 6AV2103-3XA03-0AE5 SIMATIC WinCC RC 102 400 6AV2103-4PX03-0AE5
max. PowerTags -> WinCC Professional max.

3
PowerTags and WinCC RT
as download 1)
Professional 102 400 PowerTags
floating license, software and
license key download, SIMATIC WinCC RC 153 600 6AV2103-4RX03-0AE5
email address required for the -> WinCC Professional max.
delivery PowerTags and WinCC RT
Professional 153 600 PowerTags
SIMATIC WinCC Basic 6AV2100-3AA03-0AK5
SIMATIC WinCC RC 262 144 6AV2103-4TX03-0AE5
SIMATIC WinCC Comfort 6AV2101-3AA03-0AK5
-> WinCC Professional max.
SIMATIC WinCC Advanced 6AV2102-3AA03-0AK5 PowerTags and WinCC RT
SIMATIC WinCC Professional 6AV2103-3DA03-0AK5 Professional 262 144 PowerTags
512 PowerTags as download 1)
SIMATIC WinCC Professional 6AV2103-3HA03-0AK5 upgrade license, software and
4 096 PowerTags license key download,
SIMATIC WinCC Professional 6AV2103-3XA03-0AK5 email address required for the
max. PowerTags delivery
SIMATIC WinCC RC 128 6AV2103-4BD03-0AK5
WinCC flexible 2008 -> WinCC -> WinCC Professional
V13 SP1 512 PowerTags and WinCC RT
Software and documentation Professional 128 PowerTags
on DVD, SIMATIC WinCC RC 512 6AV2103-4DD03-0AK5
upgrade license, -> WinCC Professional
license key on USB stick 512 PowerTags and WinCC RT
WinCC flexible Compact to 6AV2101-4AB03-0AE5 Professional 512 PowerTags
WinCC Comfort SIMATIC WinCC RC 2 048 6AV2103-4FH03-0AK5
WinCC flexible Standard to 6AV2101-4BB03-0AE5 -> WinCC Professional
WinCC Comfort 4 096 PowerTags and WinCC RT
WinCC flexible Advanced to 6AV2102-4AA03-0AE5 Professional 2 048 PowerTags
WinCC Advanced SIMATIC WinCC RC 8 192 6AV2103-4KX03-0AK5
as download 1) -> WinCC Professional max.
upgrade license, software and PowerTags and WinCC RT
license key download, Professional 8 192 PowerTags
email address required for the SIMATIC WinCC RC 65 536 6AV2103-4MX03-0AK5
delivery -> WinCC Professional max.
WinCC flexible Compact to 6AV2101-4AB03-0AK5 PowerTags and WinCC RT
WinCC Comfort Professional 65 536 PowerTags
WinCC flexible Standard to 6AV2101-4BB03-0AK5 SIMATIC WinCC RC 102 400 6AV2103-4PX03-0AK5
WinCC Comfort -> WinCC Professional max.
PowerTags and WinCC RT
WinCC flexible Advanced to 6AV2102-4AA03-0AK5 Professional 102 400 PowerTags
WinCC Advanced
SIMATIC WinCC RC 153 600 6AV2103-4RX03-0AK5
WinCC V7.0 / V7.2 RC -> WinCC -> WinCC Professional max.
Professional V13 SP1 and PowerTags and WinCC RT
WinCC Runtime Professional V13 Professional 153 600 PowerTags
SP1 SIMATIC WinCC RC 262 144 6AV2103-4TX03-0AK5
Software and documentation -> WinCC Professional max.
on DVD, PowerTags and WinCC RT
upgrade license, Professional 262 144 PowerTags
license key on USB stick
1) Current information and availability regarding the new delivery package
SIMATIC WinCC RC 128 6AV2103-4BD03-0AE5
-> WinCC Professional can be found at:http://www.siemens.com/tia-online-software-delivery
512 PowerTags and
WinCC RT Professional
128 PowerTags
SIMATIC WinCC RC 512 6AV2103-4DD03-0AE5
More information
-> WinCC Professional Further information can be found in the Internet at:
512 PowerTags and
WinCC RT Professional http://www.siemens.com/tia-portal
512 PowerTags

Siemens ST 80 / ST PC 2016 3/11


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime

Overview
SIMATIC WinCC Runtime Professional visualization
software
PC-based operator control and monitoring system for
visualization and operator control of processes, production
flows, machines and plants in all sectors from the simple
single-user station through to distributed multi-user systems
and cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
Basic package expandable by means of option packages
Also included are APIs for the Runtime to utilize the open
3 programming interfaces
Integration of customer-specific ActiveX Controls created with
SIMATIC WinCC Runtime Advanced visualization software WinCC ControlDevelopment
PC-based HMI solution for single-user systems directly at the For more detailed information, refer to:
machine
http://www.siemens.com/wincc-tia-portal
Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts http://www.siemens.com/wincc-professional
Basic package expandable by means of option packages
Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
Can be integrated into automation solutions based on
TCP/IP networks
Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with e-mail communication

3/12 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

Overview Design
PC-based HMI solution for single-user systems directly at the SIMATIC WinCC Runtime Advanced is available as a software
machine. SIMATIC WinCC Runtime Advanced is configured with package with 128, 512, 2 048, 4 096 or 8 192 PowerTags.
the SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software. The term PowerTags is used to identify process variables and
area pointers that have a process link to the controller. Variables
without process link, constant limit values of variables, and mes-
Benefits sages (up to 4 000 bit-triggered messages) are also available for
Functions for all visualization tasks: additional system performance. The range of functions of
- Operator functions WinCC Runtime Advanced includes the centralized HMI compo-
- Graphics and trend displays nents for visualizing and reporting, and it can be expanded to
- Alarm logging suit requirements and costs by using optional packages.
- Report system SIMATIC WinCC Runtime Advanced is configured with the
- Archiving (option) SIMATIC WinCC Advanced or SIMATIC WinCC Professional
- Recipe management (option) configuration software.
- Audit Trail (option)
Flexible runtime functionality due to Visual Basic scripts Function
Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as Visualization via Windows-compliant user interface 3
well as e-mail communication to increase availability (option) Made up of parameterizable screen objects and faceplates
Support for simple distributed automation solutions based on created on a project-specific basis:
TCP/IP networks at the machine-level (option) Numeric and alphanumeric input/output fields
Part of the Totally Integrated Automation Portal Static text and graphic display plus vector graphics
- Direct access to the tag and message configuration of the
SIMATIC controller Dynamizable graphics from HMI symbol library
- Excellent support of the new SIMATIC S7-1500 controller Bar graph, trend curve graph with scroll and zoom function as
With symbolic addressing well as read line
Access to the new memory-optimized data blocks Signal-specific text and graphic lists
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity Buttons and switches for operator-process communication
Editing fields for process values (signals)
Application Analog display, slider as example for further screen objects
SIMATIC WinCC Runtime Advanced is the high-performance vi- Project-specific faceplates created from basic objects of the
sualization software for simple, machine-oriented visualization system
tasks. It can be used as a single-user solution for all automation Graphic displays for various standard graphic formats,
applications in production automation, process automation and e.g. bitmaps, .jpg, .wmf
building services automation.
Alarms and messages
SIMATIC WinCC Runtime Advanced can be used in combination Discrete alarms and analog alarms as well as event-driven
with the following HMI devices: Alarm-S/Alarm-D message procedure with SIMATIC S7
SIMATIC Panel PC: IPC277D, IPC277E, Panel PC 477B, The new alarm and diagnostics concept of the S7-1500
HMI IPC477C, IPC477D, Panel PC 577B, HMI IPC577C, controller is also supported
Panel PC 677B, HMI IPC677C, IPC677D
Freely-definable alarm classes for definition of acknowl-
SIMATIC Box PC: IPC227D, IPC227E, Box PC 427B, IPC427C, edgment response and display of alarm events
IPC427D, Box PC 627B, IPC627C, IPC627D, Box PC 827B,
IPC827C, IPC827D Logging of alarms and process values 1)
SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, Logging in files (e.g. CSV or TXT file) and Microsoft SQL
IPC547E, Rack PC 647B, IPC647C, IPC647D, Rack PC 847B, databases
IPC847C, IPC847D Online evaluation of process value and alarm logs
SIMATIC S7 Embedded Controller: EC31 Evaluation of process value and alarm logs using standard
SIMATIC S7 Open Controller: ET200SP Open Controller Microsoft tools such as Excel
SINUMERIK PC: PCU 50.3, PCU 50.5 Recipes 1)
Standard PCs with resolutions (W x H in pixels) of: Generation of data records for machine data or production
- 4:3 Format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024, data
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768, Display or entry of data records via a configurable screen
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200, object or via process screens distributed within the project
1980 x 1080 Transmission of data records from or to the controller
Import/export of data records from/to CSV files for further
processing with other tools (e.g. MS Excel)

1) Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be


purchased separately. For further information, refer to "WinCC options".

Siemens ST 80 / ST PC 2016 3/13


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

Function (continued)
Documentation of process data, alarm events, and recipes WinCC Sm@rtServer for the remote control via the Intranet
Time or event-driven report output and Internet 1)
User-definable layout Display and control of process screens on remote PC or Panel
A SIMATIC HMI system can be used to control or monitor
Flexible expansion of integrated system function using another system remotely; entry level for client/server configu-
Visual Basic script rations for distributed operator stations or for solutions with
Language support for multilingual projects head end or control room
Up to 32 online languages WinCC ControlDevelopment for extending the functionality
Language-dependent texts and graphics by adding own Controls 1)
Language selection during runtime Development of proprietary VB.net or C# Controls for
integration in SIMATIC WinCC Runtime Advanced
User-oriented access protection according to requirements
of regulated sectors 1)
Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
Authentication with user ID and password purchased separately. For further information, refer to "WinCC options".

3 User group-specific rights


Central system-wide user administration based on
System prerequisites
SIMATIC Logon1) SIMATIC WinCC Runtime Advanced
Monitoring of changes by operators in runtime operation1) Processor type (min.) 1) At least Intel Atom 1.3 GHz or
Recording of operator actions in an Audit Trail 1) comparable and
all CPUs of SIMATIC IPC
Onboard controller connection to many different controllers RAM (min.) 2) 2 GB
Communication via native drivers and standard OPC channel Free hard disk space 3) 2 GB on system drive "C:"
Simultaneous connection using several protocols: OPC Client Operating systems 32-bit operating systems
and SIMATIC HMI HTTP protocol are additive, i.e. they can be Windows 7 Professional SP1
used in conjunction with other controller connections Windows 7 Enterprise SP1
Windows 7 Ultimate SP1
Open communication between HMI systems and with 64-bit operating systems
higher-level systems Windows 7 Professional SP1
OPC server Windows 7 Enterprise SP1
Windows 7 Ultimate SP1
- Use of the visualization system as a data server Windows 8.1 Professional
(OPC Server) for higher-level automation components, Windows 8.1 Enterprise
e.g. control systems or systems in the office area Windows Server 2008 R2 StdE SP1
- OPC-DA-Server: tags, e.g. process values Windows Server 2012 R2 StdE
Windows 7 Home Premium SP1 (only
Communication between HMI systems is established on the WinCC Basic)
basis of Ethernet networks, or via the Intranet/Internet Windows 7 Professional SP1
- Read and write access to tags. The WinCC Runtime Windows 7 Enterprise SP1
Advanced or SIMATIC Panels provide other SIMATIC HMI Windows 7 Ultimate SP1
Windows 8.1 (only WinCC Basic)
systems or office applications with data (variables) Windows 8.1 Professional
Sending of e-mails on demand or event-driven Windows 8.1 Enterprise
- e.g. to maintenance personnel via SMTP server (Simple Mail Windows Server 2008 R2 StdE SP1
(not WinCC Basic)
Transfer Protocol) Windows Server 2012 R2 StdE
- The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required) Optical drive DVD-ROM
1)
System diagnostics via device-specific HTML pages; the In combination with options, more powerful systems may be required
following functions are available: 2)
The required RAM is determined primarily by the size of the graphics used.
- Starting and stopping the HMI runtime for maintenance 3)
Without taking archives into account.
- Remote access to recipe data records, passwords and infor-
mation specific to the HMI system
- Access to the HMI system files via a file explorer Note:
- Download of configuration data via the Intranet/Internet In addition to WinCC, Windows also requires space on the hard
- Supplement with own HTML pages disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation.

3/14 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

Technical specifications
The following tables of system limitations provide assistance in of configurations that make full use of all system limits on the HMI
estimating whether a specific project is still within the system devices. In addition to the limitations specified, allowances must
limitations for WinCC Runtime Advanced. The stated maximum be made for restrictions in configuration memory resources.
values are not additive. We cannot guarantee proper functioning

SIMATIC WinCC Runtime Advanced SIMATIC WinCC Runtime Advanced


Tags Trends
Number of tags in the project 6 144 Number of trends 800
Number of PowerTags 128 4 096 Text lists and graphics lists
Number of elements per array 1 600 Number of graphic lists 500
Number of local tags 2 048 Number of text lists 500
Alarms Number of entries per text or 3 500
graphic list

3
Number of alarm classes 32
Number of graphic objects 2 000
Number of discrete alarms 4 000
Number of text elements 30 000
Number of analog alarms 500
Scripts
Length of an alarm in characters 80
Number of scripts 200
Number of process values per alarm 8
Communication
Size of the alarm buffer 1 024
Number of connections 8
Number of queued alarm events 500
Number of connections based on 16
Screens "SIMATIC HMI HTTP"
Number of screens 500 Maximum number of connected 44)
Number of fields per screen 400 Sm@rtClients (including a service
client)
Number of tags per screen 400
Help system
Number of complex objects per 40
screen1) Number of characters in a help text 320
Recipes Languages

Number of recipes 999 Number of runtime languages 32


Number of elements per recipe2) 2 000 Scheduler

User data length in KB per data 256 Time-triggered tasks5) 48


record User administration
Number of data records per recipe 5 000 Number of user groups 50
Logs Number of user rights 32
Number of logs 100 Number of users 100
Number of entries per log 500 000
(including all log segments)3)
Number of log segments 400
Cyclical trigger for tag logging 1s
Number of tags that can be logged 6 144
per log
1)
Complex objects are: Bars, sliders, symbol library, clock, and all objects
from the Controls area.
2)
When using arrays, each array element represents a recipe element
3)
For the "segmented circular log" logging method, the number of entries for
all sequence logs is valid. The product derived from the number of circular
logs times the number of data records in this log may not be exceeded.
4)
Up to three Sm@rtClients can interconnect with the Sm@rtServer on
Panel PC 477.
5)
Event-triggered tasks are not relevant for the system limits.

Siemens ST 80 / ST PC 2016 3/15


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

Ordering data Article No. Article No.

Basic packages SIMATIC WinCC Runtime


Advanced V13 SP1 to
SIMATIC WinCC Runtime SIMATIC WinCC Runtime
Advanced V13 SP1 Professional V13 SP1
Software and documentation on Single license, software and
DVD, including options software 1) documentation on DVD,
Single license, license key on license key on USB stick for
USB stick PowerTags from
128 PowerTags 6AV2104-0BA03-0AA0 128 PowerTags to 128 PowerTags 6AV2105-2BB03-0AC0
512 PowerTags 6AV2104-0DA03-0AA0 512 PowerTags to 512 PowerTags 6AV2105-2DD03-0AC0
2 048 PowerTags 6AV2104-0FA03-0AA0 2 048 PowerTags to 6AV2105-2FF03-0AC0
4 096 PowerTags 6AV2104-0HA03-0AA0 2 048 PowerTags
8 192 PowerTags 6AV2104-0KA03-0AA0 4 096 PowerTags to 6AV2105-2HH03-0AC0
4 096 PowerTags
3)
as download 8 192 PowerTags to 6AV2105-2KK03-0AC0
Single license, software and license 8 192 PowerTags
key download.
as download 3)

3
email address required for the
delivery. Single license, software and
128 PowerTags 6AV2104-0BA03-0AH0 license key download.
512 PowerTags 6AV2104-0DA03-0AH0 email address required for the
delivery.
2 048 PowerTags 6AV2104-0FA03-0AH0
128 PowerTags to 128 PowerTags 6AV2105-2BB03-0AJ0
4 096 PowerTags 6AV2104-0HA03-0AH0
512 PowerTags to 512 PowerTags 6AV2105-2DD03-0AJ0
8 192 PowerTags 6AV2104-0KA03-0AH0
2 048 PowerTags to 6AV2105-2FF03-0AJ0
Powerpacks 2 048 PowerTags
4 096 PowerTags to 6AV2105-2HH03-0AJ0
SIMATIC WinCC Runtime
4 096 PowerTags
Advanced V13
(without version change) 8 192 PowerTags to 6AV2105-2KK03-0AJ0
8 192 PowerTags
Single license, license key only on
USB stick for PowerTags from SIMATIC WinCC Runtime
128 PowerTags to 512 PowerTags 6AV2104-2BD03-0BD0 Advanced V13 SP1 to
512 PowerTags to 6AV2104-2DF03-0BD0 SIMATIC WinCC Runtime
2 048 PowerTags Professional ASIA V13 SP1
2 048 PowerTags to 6AV2104-2FH03-0BD0 128 PowerTags to 128 PowerTags 6AV2105-2BB13-0AC0
4 096 PowerTags 512 PowerTags to 512 PowerTags 6AV2105-2DD13-0AC0
4 096 PowerTags to 6AV2104-2HK03-0BD0 2 048 PowerTags to 6AV2105-2FF13-0AC0
8 192 PowerTags 2 048 PowerTags
4 096 PowerTags to 6AV2105-2HH13-0AC0
as download 3)
4 096 PowerTags
Single license, software and 8 192 PowerTags to 6AV2105-2KK13-0AC0
license key download. 8 192 PowerTags
email address required for the
delivery. Update
128 PowerTags to 512 PowerTags 6AV2104-2BD03-0BJ0 SIMATIC WinCC Runtime 6AV2105-0XX03-0DU8
512 PowerTags to 6AV2104-2DF03-0BJ0 Advanced V13 to V13 SP1
2 048 PowerTags
2 048 PowerTags to 6AV2104-2FH03-0BJ0 Software and documentation on
4 096 PowerTags DVD, including options software
(only DVD, without license key)
4 096 PowerTags to 6AV2104-2HK03-0BJ0
8 192 PowerTags

3/16 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

Ordering data Article No. Article No.


Upgrades SIMATIC WinCC flexible Panel 6AV2107-4XP00-0BF0
Options to
SIMATIC WinCC Runtime SIMATIC WinCC (TIA Portal)
Advanced V11..12 to V13 SP1 Panel Options
Software and documentation on WinCC flexible /Audit
DVD, including options software for SIMATIC Panels to
single license, license keys on USB SIMATIC WinCC Audit for
stick for SIMATIC Panels
128 PowerTags 6AV2104-3BB03-0AE0 WinCC flexible /Sm@rtAccess
512 PowerTags 6AV2104-3DD03-0AE0 for SIMATIC Panel to
2 048 PowerTags 6AV2104-3FF03-0AE0 SIMATIC WinCC Sm@rtServer for
SIMATIC Panels
4 096 PowerTags 6AV2104-3HH03-0AE0
WinCC flexible /Sm@rtService
8 192 PowerTags 6AV2105-3KK03-0AE0 for SIMATIC Panels to
as download 3) SIMATIC WinCC Sm@rtServer for
SIMATIC Panels
Single license, software and
license key download. as download 3)
email address required for the Single license,
license key download only.
3
delivery.
128 PowerTags 6AV2104-3BB03-0AK0 email address required for the
512 PowerTags 6AV2104-3DD03-0AK0 delivery.
2 048 PowerTags 6AV2104-3FF03-0AK0 SIMATIC WinCC flexible Panel 6AV2107-4XP00-0BK0
4 096 PowerTags 6AV2104-3HH03-0AK0 Options to
8 192 PowerTags 6AV2104-3KK03-0AK0 SIMATIC WinCC (TIA Portal)
Panel Options
SIMATIC WinCC flexible 2008 to WinCC flexible /Audit for
SIMATIC WinCC Runtime SIMATIC Panels to
Advanced V13 SP1 SIMATIC WinCC Audit for
Software and documentation on SIMATIC Panels
DVD, including options software WinCC flexible /Sm@rtAccess for
single license, license keys on USB SIMATIC Panel to SIMATIC WinCC
stick for Sm@rtServer for SIMATIC Panels
128 PowerTags to 6AV2104-4BB03-0AE0 WinCC flexible /Sm@rtService for
128 PowerTags 2) SIMATIC Panels to SIMATIC
512 PowerTags to 6AV2104-4DD03-0AE0 WinCC Sm@rtServer
512 PowerTags 2) for SIMATIC Panels
2 048 PowerTags to 6AV2104-4FF03-0AE0
2 048 PowerTags 2)
4 096 PowerTags to 6AV2104-4HH03-0AE0
4 096 PowerTags 2)
8 000 PowerTags to 6AV2104-4KK03-0AE0
8 192 PowerTags 2)
as download 3)
Single license, software and
license key download.
email address required for the
delivery.
128 PowerTags to 6AV2104-4BB03-0AK0
128 PowerTags 2)
512 PowerTags to 6AV2104-4DD03-0AK0
512 PowerTags 2) 1)
Runtime licenses for WinCC Runtime Advanced options must be
2 048 PowerTags to 6AV2104-4FF03-0AK0 purchased separately for each target system
2 048 PowerTags 2)
2)
4 096 PowerTags to 6AV2104-4HH03-0AK0 Each including 1 upgrade license to the WinCC Runtime Advanced
4 096 PowerTags 2) options
3)
8 000 PowerTags to 6AV2104-4KK03-0AK0 Current information and availability regarding the new delivery package
8 192 PowerTags 2) can be found at: http://www.siemens.com/tia-online-software-delivery

More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal

Siemens ST 80 / ST PC 2016 3/17


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

Overview Design
PC-based operator control and monitoring system for SIMATIC WinCC Runtime Professional is available as a software
visualization and operator control of processes, production package with 128, 512, 2 048, 4 096, 8 192, 65 536, 102 400,
flows, machines and plants in all sectors from the simple 153 600 and 262 144 PowerTags.
single-user station through to distributed multi-user systems
and cross-location solutions with web clients. PowerTags are data points that are connected to controllers or
other data sources via a WinCC Runtime Professional channel.
SIMATIC WinCC Runtime Professional is the information hub for Up to 32 alarms can be obtained from one data point. Moreover,
corporation-wide vertical integration. SIMATIC WinCC Runtime internal tags without coupling are available for additional system
Professional is configured with the SIMATIC WinCC Professional performance. WinCC Runtime Professional also contains
configuration software. 500 archive tags. Additional archive licenses can be obtained
for greater quantity structures.
Benefits Licenses for a multi-user configuration
Functions for all visualization tasks: The system software with the required number of PowerTags and
- Operator functions additionally the SIMATIC WinCC Server for Runtime Professional
- Graphics and trend displays option must be installed on the server. For the clients in the basic
- Alarm logging
3
configuration, a SIMATIC WinCC Client for Runtime Professional
- Report system license is sufficient.
- Archiving (option)
Function
- Recipe management (option)
Universally scalable
- Expandable from single station to client-server Visualization via Windows-compliant user interface
configurations
- Process visualization via the web with the WinCC Made up of parameterizable screen objects and faceplates
WebNavigator created on a project-specific basis:
Open standards for easy integration Numeric and alphanumeric input/output fields
- Efficient real-time database MS SQL Server Static text and graphic display plus vector graphics
- Open for application modules with ActiveX controls Dynamizable graphics from HMI symbol library
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication Bar graph, trend curve graph with scroll and zoom function as
well as read line
Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the Signal-specific text and graphic lists
SIMATIC controller Buttons and switches for operator-process communication
- Excellent support of the new SIMATIC S7-1500 controller Editing fields for process values (signals)
With symbolic addressing
Access to the new memory-optimized data blocks Analog display, slider as example for further screen objects
New alarm and diagnostics concept Project-specific faceplates created from basic objects of the
- Integrated diagnostic functions for increasing productivity system
Graphic displays for various standard graphic formats,
Application e.g. bitmaps, .jpg, .wmf
SIMATIC WinCC Runtime Professional is designed for visualiza- Alarms and messages
tion and operation of processes, manufacturing cycles, Discrete alarms and analog alarms, as well as event-driven
machines and plants. With its powerful process interface, Alarm-S/Alarm-D message procedure with SIMATIC S7
especially to the SIMATIC family, and the secure data logging,
WinCC Runtime Professional enables solutions for the process The new alarm and diagnostics concept of the S7-1500
control. controller is also supported
Freely-definable alarm classes for definition of acknowl-
The sector-neutral basic system enables universal usage in all
edgment response and display of alarm events
automation applications.
SIMATIC WinCC Runtime Professional can be used in Logging of alarms and process values 1)
combination with the following HMI devices: Signaling system for detecting and archiving events with
display and control options according to DIN 19235
SIMATIC PCs:
Process logging for the acquisition, compression and storage
SIMATIC Panel PC: HMI IPC477C (Client), IPC477D (Client), of measured values
Panel PC 577B, HMI IPC577C (Client), Panel PC 677B,
HMI IPC677C Online evaluation of process value and alarm logs
SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B, 1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
IPC627C, IPC627D, IPC827C, IPC827D purchased separately. For further information, refer to "WinCC options".
SIMATIC Rack PC: PC 547B, IPC547C, IPC547D, IPC547E,
PC 647B, IPC647C, IPC647D, PC 847B, IPC827C, IPC827D
Standard PC

3/18 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

Function (continued)
Recipes 1) Language support for multilingual projects
Generation of data records for machine data or production Language-dependent texts and graphics
data Language selection during runtime
Display or entry of data records via a configurable screen
object or via process screens distributed within the project Onboard controller connection to many different controllers
Transmission of data records from or to the controller Communication via native drivers and standard OPC channel
Import/export of data records for further processing with other For communication with subordinate controls (SIMATIC
tools (e.g. MS Excel) protocols, PROFIBUS DP, PROFIBUS FMS, DDE and OPC
server included in the scope of delivery)
Documentation of process data, alarm events, and recipes
WinCC ControlDevelopment for extending the functionality
Time or event-driven report output by adding own Controls 1)
User-definable layout Development of proprietary VB.net or C# Controls for
Flexible expansion by means of Visual Basic Script and integration in WinCC Runtime Professional
ANSI-C
3
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
Programming interfaces for individual access to data and purchased separately. For further information, refer to "WinCC options".
functions of WinCC Runtime Professional and for the
integration in user programs with VBA, VB Script, C-API,
C-Script (ANSI-C) System prerequisites SIMATIC WinCC Runtime Professional

Open communication between HMI systems and with Processor type (min.) 1) Windows 7 (32-bit): 3.5 GHz P4 or
comparable, dual core
higher-level systems
Windows Server 2008: 3 GHz P4 or
OPC-Server comparable, dual/multi core
Use of the visualization system as a data server (OPC Server)
RAM (min.) 2) 2 GB
for higher-level automation components such as control
systems or systems in the office sector Free hard disk space 3) 2 GB on system drive "C:"
- OPC-DA-Server: tags, e.g. process values Operating systems 32-bit operating systems
- OPC-HDA-Server: logged process values Windows 7 Professional SP1
- OPC-A&E-Server: Alarms Windows 7 Enterprise SP1
- OPC-XML-DA-Server: tags, e.g. process values Windows 7 Ultimate SP1
- OPC-UA-DA Server: tags, e.g. process values 64-bit operating systems
Windows 7 Professional SP1
OLE DB Server Windows 7 Enterprise SP1
- Standardized and user-friendly access to WinCC log data Windows 7 Ultimate SP1
(MS SQL Server 2005). Windows 8.1 Professional
- Access is via the OLE-DB Provider supplies all WinCC log Windows 8.1 Enterprise
Windows Server 2008 R2 StdE SP1
data available along with the accompanying process values, Windows Server 2012 R2 StdE
as well as alarm and user texts.
- The WinCC OLE-DB provider also supports analysis Graphics card 32 MB RAM, 24 bit color depth
functions such as minimum, maximum, alarm hit list, etc. Network Ethernet 10 Mbit/s or higher
WinCC WebNavigator for Runtime Professional 1) Optical drive DVD-ROM
- Option for SIMATIC WinCC Runtime Professional for 1)
operating and monitoring plants over the Internet, company In combination with options, more powerful systems may be required
2) The required RAM is determined primarily by the size of the graphics used.
Intranet or LAN.
- Configuration from a web server with the SIMATIC WinCC 3)
Without taking archives into account.
Runtime Professional software as a single-user, client or
server version and a web client that enables operator control Note:
and monitoring of a current WinCC Runtime Professional
project via an Internet browser with ActiveX support. The In addition to WinCC, Windows also requires space on the hard
WinCC basic system does not have to be installed on the disk; e.g. free disk space should be available for the swap file.
client computer. The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM. For further information, refer to your
WinCC DataMonitor for Runtime Professional 1)
Windows documentation.
- The WinCC DataMonitor is used for displaying and evalu-
ating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel. The DataMonitor Client is supported by a
web server with current and historic process data and
alarms. All staff ranging from machine operators to corporate
managers can use the DataMonitor to obtain information.

Siemens ST 80 / ST PC 2016 3/19


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

Integration
Integration in company-wide solutions Access. Just as important: Visual Basic Scripting (VBS) as an
(IT and business integration) easy-to-learn, open Runtime language. If desired, professional
application developers can also use ANSI-C.
WinCC Runtime Professional is strictly based on Microsoft tech-
nology, which provides for the greatest possible compatibility WinCC Runtime Professional integrates a powerful and scalable
and integration ability. ActiveX and .net Controls support tech- Historian function based on the Microsoft SQL Server in the
nology and sector-specific expansions. Cross-manufacturer basic system. Thus the user is given all possibilities: from high-
communication is also a simply exercise. The reason: WinCC performance archiving of current process data, to long-term
Runtime Professional can be used as an OPC client and server, archiving with high data compression, through to a central infor-
and in addition to access to current process values, it also mation turntable in form of a company-wide Process Historian.
supports standards such as OPC HDA (Historical Data Access), Open interfaces form the basis for an effective IT and business
OPC Alarm & Events, OPC UA Data Access and OPC XML Data integration.

Technical specifications
The following tables of system limits provide assistance in We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices.
3
estimating whether a specific project is still within the system
limitations for WinCC Runtime Professional. The stated maximum In addition to the limitations specified, allowances must be made
values are not additive. for restrictions in configuration memory resources.

SIMATIC WinCC Runtime SIMATIC WinCC Runtime


Professional Professional
Alarms Logs
Configurable alarms per 20 000 Trend views per screen 25
server/single user
Trends per trend view 80
PowerTags per alarm line 10
Tables per screen 25
User text blocks per alarm line 10
Columns per table 12
Alarm classes (incl. system alarm 18
classes) Values per table 30 000

Alarm types 16 Logs per single-user station/server 100

Alarm priorities 17 (0...16) Log tags per single-user 8 000


station/server 7)
Alarms in Runtime
Trends
Alarms per alarm log Unlimited1)
Trend views per image 25
Alarms per short-term log list 1 000
Trends per trend view 80
Alarms per long-term log list 1 0002)
User administration
Alarms per alarm display 5 0003)
Number of user groups 128
Screens
Number of user rights 999
Objects per screen 4) 3 0005)
Number of users 128
Levels per screen 32
Configurations Quantity
Screens per project 1 0005) structure in a multi-user system
Instances of fixed faceplates in a 31 instances of the same picture type WinCC clients in a system 328) 9)
process screen
Web clients in a system 5010)
Screen size in pixels 10 000 x 10 000
Nesting levels of screen objects 20
Recipes
Number of recipes 1 0005)
Number of recipe elements 5006)
Number of recipe data records 3 0006)
Number of views Unlimited5)

1) 6)
Limited by system resources. The sum of the number of recipe elements and number of data records
2)
On single-user station or server or on client per server if must not exceed a value of 320,000.
7)
"LongTimeArchiveConsistency" is set to "No". On single-user station, Dependent on the Logging PowerPack used for the log tags. 500 log tags
server, or client if "LongTimeArchiveConsistency" is set to "Yes". are contained in the basis version.
3) 8)
On single-user station or server or on client per server. If the server is also used as an operating unit, the number of clients for this
4) The number and complexity of the objects affect the performance. server is reduced to four.
9) Mixed configuration: 32 Clients + 3 Web Clients
5) Limited by system resources.
10) Mixed configuration: 50 Web Clients + 1 WinCC Client

3/20 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

Ordering data Article No. Article No.

Basic software Powerpacks


SIMATIC WinCC Runtime SIMATIC WinCC Runtime
Professional V13 SP1 Professional V13 and
For PC systems; SIMATIC WinCC Runtime
incl. software options 1), Professional ASIA V13
language/script versions: Single license, license key only on
De, En, Fr, It, Es USB sticks for PowerTags from
Single License, on DVD 128 to 512 PowerTags 6AV2105-2BD03-0BD0
incl. licensing, on USB stick, 512 to 2 048 PowerTags 6AV2105-2DF03-0BD0
for:
2 048 to 4 096 PowerTags 6AV2105-2FH03-0BD0
128 PowerTags 6AV2105-0BA03-0AA0
4 096 to 8 192 PowerTags 6AV2105-2HK03-0BD0
512 PowerTags 6AV2105-0DA03-0AA0
8 192 to 65 536 PowerTags 6AV2105-2KM03-0BD0
2 048 PowerTags 6AV2105-0FA03-0AA0
65 536 to 102 400 PowerTags 6AV2105-2MP03-0BD0
4 096 PowerTags 6AV2105-0HA03-0AA0
102 400 to 153 600 PowerTags 6AV2105-2PR03-0BD0
8 192 PowerTags 6AV2105-0KA03-0AA0
153 600 to 262 144 PowerTags 6AV2105-2RT03-0BD0
65 536 PowerTags 6AV2105-0MA03-0AA0
as download 3)
3
102 400 PowerTags 6AV2105-0PA03-0AA0
153 600 PowerTags 6AV2105-0RA03-0AA0 Single license,
262 144 PowerTags 6AV2105-0TA03-0AA0 license key download only.
email address required for the
Incl. 500 archive tags each delivery.
as download 3) 128 to 512 PowerTags 6AV2105-2BD03-0BJ0
Single license, software and 512 to 2 048 PowerTags 6AV2105-2DF03-0BJ0
license key download. 2 048 to 4 096 PowerTags 6AV2105-2FH03-0BJ0
email address required for the 4 096 to 8 192 PowerTags 6AV2105-2HK03-0BJ0
delivery. 8 192 to 65 536 PowerTags 6AV2105-2KM03-0BJ0
128 PowerTags 6AV2105-0BA03-0AH0 65 536 to 102 400 PowerTags 6AV2105-2MP03-0BJ0
512 PowerTags 6AV2105-0DA03-0AH0 102 400 to 153 600 PowerTags 6AV2105-2PR03-0BJ0
2 048 PowerTags 6AV2105-0FA03-0AH0 153 600 to 262 144 PowerTags 6AV2105-2RT03-0BJ0
4 096 PowerTags 6AV2105-0HA03-0AH0
Upgrades WinCC V11..12 to
8 192 PowerTags 6AV2105-0KA03-0AH0 WinCC V13 SP1
65 536 PowerTags 6AV2105-0MA03-0AH0
102 400 PowerTags 6AV2105-0PA03-0AH0 SIMATIC WinCC Runtime
Professional V11..12 and
153 600 PowerTags 6AV2105-0RA03-0AH0
262 144 PowerTags 6AV2105-0TA03-0AH0 SIMATIC WinCC Runtime
Professional ASIA V11..V12 to
Incl. 500 archive tags each V13 SP1
SIMATIC WinCC Runtime Single license, on DVD
Professional ASIA V13 SP1 incl. licensing on USB stick
For PC systems; SIMATIC WinCC Runtime 6AV2105-3BB03-0AE0
incl. software options 1), Professional 128 PowerTags
language/script versions: SIMATIC WinCC Runtime 6AV2105-3DD03-0AE0
En, Chs, Cht, Kor, Jpn Professional 512 PowerTags
Single License, on DVD SIMATIC WinCC Runtime 6AV2105-3FF03-0AE0
incl. licensing, for: Professional 2 048 PowerTags
128 PowerTags 6AV2105-0BA13-0AA0 SIMATIC WinCC Runtime 6AV2105-3HH03-0AE0
512 PowerTags 6AV2105-0DA13-0AA0 Professional 4 096 PowerTags
2 048 PowerTags 6AV2105-0FA13-0AA0 SIMATIC WinCC Runtime 6AV2105-3KK03-0AE0
4 096 PowerTags 6AV2105-0HA13-0AA0 Professional 8 192 PowerTags
8 192 PowerTags 6AV2105-0KA13-0AA0 SIMATIC WinCC Runtime 6AV2105-3MM03-0AE0
Professional 65 536 PowerTags
65 536 PowerTags 6AV2105-0MA13-0AA0
102 400 PowerTags 6AV2105-0PA13-0AA0 as download 3)
153 600 PowerTags 6AV2105-0RA13-0AA0 Single license, software and
license key download.
262 144 PowerTags 6AV2105-0TA13-0AA0
email address required for the
Incl. 500 archive tags each delivery.
SIMATIC WinCC Runtime 6AV2105-3BB03-0AK0
SIMATIC WinCC Client for
Professional 128 PowerTags
Runtime Professional V13 SP1
SIMATIC WinCC Runtime 6AV2105-3DD03-0AK0
WinCC Client for Runtime 6AV2107-0DB03-0AA0
Professional 512 PowerTags
Professional
SIMATIC WinCC Runtime 6AV2105-3FF03-0AK0
WinCC Client for Runtime 6AV2107-0DB03-0AH0
Professional 2 048 PowerTags
Professional (as download 3))
SIMATIC WinCC Runtime 6AV2105-3HH03-0AK0
WinCC Client for Runtime 6AV2107-0DB13-0AA0
Professional 4 096 PowerTags
Professional ASIA
SIMATIC WinCC Runtime 6AV2105-3KK03-0AK0
Professional 8 192 PowerTags
SIMATIC WinCC Runtime 6AV2105-3MM03-0AK0
Professional 65 536 PowerTags

1)
Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.
3)
Current information and availability regarding the new type of delivery can
be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC 2016 3/21


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

Ordering data Article No. Article No.


3)
Upgrades WinCC V7.0/V7.2 to as download
WinCC V13 SP1 Single license, software and
SIMATIC WinCC Runtime license key download.
V7.0/V7.2 to email address required for the
SIMATIC WinCC Runtime delivery.
Professional V13 SP1 and WinCC Runtime 128 PowerTags to 6AV2105-4BB03-0AK0
WinCC Runtime Professional
SIMATIC WinCC Runtime 128 PowerTags 2)
V7.0/V7.2 ASIA to
SIMATIC WinCC Runtime WinCC Runtime 512 PowerTags to 6AV2105-4DD03-0AK0
Professional ASIA V13 SP1 WinCC Runtime Professional
512 PowerTags 2)
Single license, on DVD
incl. licensing on USB stick WinCC Runtime 2 048 PowerTags 6AV2105-4FF03-0AK0
to WinCC Runtime Professional
WinCC Runtime 128 PowerTags to 6AV2105-4BB03-0AE0 2 048 PowerTags 2)
WinCC Runtime Professional
128 PowerTags2) WinCC Runtime 8 192 PowerTags 6AV2105-4KK03-0AK0
to WinCC Runtime Professional
WinCC Runtime 512 PowerTags to 6AV2105-4DD03-0AE0 8 192 PowerTags 2)
WinCC Runtime Professional
512 PowerTags 2) WinCC Runtime 6AV2105-4MM03-0AK0

3 WinCC Runtime 2 048 PowerTags


to WinCC Runtime Professional
6AV2105-4FF03-0AE0
65 536 PowerTags to
WinCC Runtime Professional
65 536 PowerTags 2)
2 048 PowerTags 2)
WinCC Runtime 6AV2105-4PP03-0AK0
WinCC Runtime 8 192 PowerTags 6AV2105-4KK03-0AE0 102 400 PowerTags to WinCC
to WinCC Runtime Professional Runtime Professional 102 400 2)
8 192 PowerTags 2)
WinCC Runtime 6AV2105-4RR03-0AK0
WinCC Runtime 6AV2105-4MM03-0AE0 153 600 PowerTags to WinCC
65 536 PowerTags to Runtime Professional 153 600 2)
WinCC Runtime Professional
65 536 PowerTags 2) WinCC Runtime 6AV2105-4TT03-0AK0
262 144 PowerTags to WinCC
WinCC Runtime 6AV2105-4PP03-0AE0 Runtime Professional 262 144 2)
102 400 PowerTags to WinCC
Runtime Professional 102 400 2) WinCC RC/RT128 / RC/RT 6AV2107-4DB03-0AK0
Client to WinCC Client for Runtime
WinCC Runtime 6AV2105-4RR03-0AE0 Professional
153 600 PowerTags to WinCC
Runtime Professional 153 600 2)
WinCC Runtime 6AV2105-4TT03-0AE0
262 144 PowerTags to WinCC
Runtime Professional 262 144 2)
WinCC RC/RT128 / RC/RT 6AV2107-4DB03-0AE0
Client to WinCC Client for Runtime
Professional
1)
Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.
2)
Each including 1 upgrade license to the WinCC Runtime Professional
options.
3)
Current information and availability regarding the new type of delivery can
be found at: http://www.siemens.com/tia-online-software-delivery

More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
http://www.siemens.com/wincc-professional

3/22 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

Overview
Communication SIMATIC WinCC Runtime Advanced Protocol Description PC interface
WinCC Advanced is an open visualization system and offers the Third-party controllers (from WinCC V11.0) 3)
option of connecting the most diverse control systems. Allen Bradley Channel for communication with max. CP 1612 A2
Number of connectable controllers Ethernet IP 4 x Allen Bradley controllers via
Ethernet TCP/IP with Allen Bradley
WinCC Advanced permits the parallel coupling of up to Ethernet IP protocol
The controllers ControlLogix /
8 controllers. CompactLogix, SLC500 / MicroLogix
Connection to third-party controllers and PLC5 are supported
The following "Coupling overview" table includes lists of Allen Bradley DF1 Channel for communication with Allen COM1/COM2
third-party protocols and controllers which are directly Bradley controllers via DF1 protocol
supported by WinCC Advanced. Generally it is also possible The controllers SLC500 / MicroLogix
and PLC5 are supported 3)
to connect third-party controllers via OPC (OLE for Process
Control). Mitsubishi MC Channel for communication with max. CP 1612 A2
TCP/IP 4 x Mitsubishi controllers via Ethernet
Current notes and information about OPC servers from many TCP/IP with Mitsubishi MC TCP/IP
different suppliers can be found at:
3
protocol
http://www.opcfoundation.org/ The FX3, Q, and iQ/QnUD controller
series are supported
WinCC Advanced supports the standards: Mitsubishi FX Channel for communication with COM1/COM2
OPC Data Access 2.05a Mitsubishi controllers via FX protocol
The FX1N, FX2N controllers are
OPC UA Data Access 1.01 supported
OPC XML Data Access 1.00 (client via DCOM/XML gateway) Modbus TCP/IP Channel for communication with max. CP 1612 A2
4 x Modicon controllers via Ethernet
Coupling overview for WinCC Runtime Advanced TCP/IP using the Modbus TCP/IP
protocol
Protocol Description PC interface The Quantum, Momentum, Premium,
TSX Micro, Compact and M340
SIMATIC HMI controllers are supported
Ethernet TCP/IP HTTP communication for data CP 1612 A2 Modbus RTU Channel for communication with COM1/COM2
(HTTP exchange between SIMATIC HMI Modicon controllers via the Modbus
communication) (client + server) 1) RTU protocol
SIMATIC S7 The Quantum, Momentum, and
Compact controllers are supported
Ethernet TCP/IP Channel for communication via CP 1612 A2
(S7 communication) Ethernet TCP/IP with max. CP 1613 A2 Omron Link / Channel for communication with COM1/COM2
8 x SIMATIC S7 controllers CP 1623 Multi Link Omron controllers via the Link/
S7-1200, S7-1500 Multi protocol
S7-300, S7-400, The CP1x, CJ1x, CJ2H, CS1x, and
S7-200 with CP 243-1 CP2MC controllers are supported
MPI, PROFIBUS Channel for communication via CP 5611 A2 Cross-vendor
(S7 communication) MPI, PROFIBUS with max. CP 5612 OPC client 1) 4) Channel for OPC communication, CP 1612 A2
8 x SIMATIC S7 controllers CP 5621 for OPC DA, WinCC can acquire data from OPC
S7-1200 with CM 1243-5 (DP master), CP 5622 OPC UA DA, server applications
S7-1500 CP 5711 XML DA
CP 5613 A2
S7-300, S7-400, CP 5613 A3 OPC server Server applications for OPC communi- CP 1612 A2
S7-200 (passive S7-200 only) CP 5623 for OPC DA cation; WinCC provides process data
to OPC clients
PPI Channel for communication via CP 5611 A2
(PPI protocol) PPI with CP 5612 1) HTTP and OPC communication can be used in combination with the other
1 x SIMATIC S7-200 CP 5621 couplings; regarding SIMATIC Panels that support HTTP or OPC commu-
(network operation, e.g. parallel PG CP 5622 nication, see the overview under "System interfaces (WinCC V11)".
possible) CP 5711 2) "SINUMERIK Operate WinCC RT Advanced" license required; for further
CP 5613 A2
information, see NC 60 Catalog.
CP 5613 A3
3) For detailed information regarding supported controllers, see "System
CP 5623
interfaces (WinCC V11)"
Software interface Channel for communication via 4)
(S7 communication) software interface with WinAC Application note: Parallel use of the OPC client channel allows, for
example, connection to an SNMP OPC Server for visualization of the data
SINUMERIK 2) present there. The SNMP OPC Server enables monitoring of any network
components (e.g. switches) that support the SNMP protocol. Further
Ethernet TCP/IP Channel for communication via CP 1612 A2 information can be foundunder SIMATIC NET communications systems/
(S7 communication) Ethernet TCP/IP CP 1613 A2 SNMP OPC Server.
with SINUMERIK 840D sl CP 1623
MPI Channel for communication via CP 5611 A2
(S7 communication) MPI with SINUMERIK 840D sl CP 5612
CP 5621
CP 5622
CP 5711
CP 5613 A2
CP 5613 A3
CP 5623

Siemens ST 80 / ST PC 2016 3/23


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

Overview (continued)
Communication SIMATIC WinCC Runtime Professional Coupling overview for WinCC Runtime Professional
WinCC Professional is an open process visualization system and Protocol Description PC interface
offers the option of connecting the most diverse control systems.
SIMATIC S7
Released communication software SIMATIC S7 Protocol Suite with channel units for CP 5611 A2
Only communication software with the listed (or higher) product communication with SIMATIC S7 via CP 5612
Ethernet TCP/IP
versions should be used. Corresponding SIMATIC NET (S7 communication) to CP 5621
upgrades are available for the upgrading of older versions. S7-1200, S7-1500, S7-300, S7-400 CP 5622
MPI, PROFIBUS
Number of connectable controllers (S7 communication) to CP 5711
S7-1200 with CM 1243-5 (DP master), CP 5613 A3
With CP 1613 A2/CP 1623, a maximum of 64 S7 controllers can S7-1500, S7-300, S7-400
be connected via Industrial Ethernet; with CP 5612/CP 5622 a CP 5623
Software interface
maximum of 8 and with CP 5613 A3 a maximum of 44 S7 control- (S7 communication) to Win AC
lers via PROFIBUS. With approx. 10 or more controllers, the use Non-Siemens controllers (from WinCC V11.0)
of Industrial Ethernet is recommended.
Allen Bradley Channel for communication with Allen CP 1612 A2

3 Client-server communication
Communication between the clients and the server is
Ethernet IP Bradley controllers via Ethernet TCP/IP
with Ethernet IP protocol
The controllers ControlLogix /
implemented using the TCP/IP protocol. The construction of CompactLogix,
a separate PC-LAN is recommended. For small projects with SLC500 / MicroLogix, and PLC5 are
correspondingly small message frame advent, a SIMATIC NET supported
Industrial Ethernet can be used for both process communication Mitsubishi MC Channel for communication with CP 1612 A2
(WinCC/server PLC) and for PC-PC communication TCP/IP Mitsubishi controllers via Ethernet
(WinCC/client WinCC/server) TCP/IP with Mitsubishi MC TCP/IP
protocol
Connection to third-party controllers The FX3, Q, and iQ/QnUD controller
series are supported
The following "Coupling overview" table includes lists of Modbus TCP/IP Channel for communication with CP 1612 A2
third-party protocols and controllers which are directly Modicon controllers via Ethernet
supported by WinCC Professional. Generally it is also TCP/IP using the Modbus TCP/IP
possible to connect third-party controllers via OPC protocol
(OLE for Process Control). The Quantum, Momentum, Premium,
TSX Micro, Compact and M340 con-
Current notes and information about OPC servers from many trollers are supported
different suppliers can be found at: Cross-vendor
http://www.opcfoundation.org/
OPC client 1) Channel for OPC communication, CP 1612 A2
WinCC Professional supports the standards: for OPC DA, WinCC can acquire data from OPC
OPC XML DA server applications
OPC Data Access 2.05a
OPC server Server applications for OPC communi- CP 1612 A2
OPC Data Access 3.00 for OPC DA, cation; WinCC provides process data
OPC UA Data Access 1.01 OPC UA DA, to OPC Clients
OPC XML DA,
OPC XML Data Access 1.00 OPC A&E,
OPC HDA
OPC HDA 1.20
1) Application note: Parallel use of the OPC client channel allows, for
OPC A&E 1.10
example, connection to an SNMP OPC Server for visualization of the data
present there. The SNMP OPC Server enables monitoring of any network
components (e.g. switches) that support the SNMP protocol. Further infor-
mation can be found under SIMATIC NET communications systems/
SNMP OPC Server.

3/24 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

Overview (continued)
Communications examples

Industrial Ethernet

SIMATIC S7-400

WinCC
Runtime
Advanced

PROFIBUS 3
SIMATIC S7-300
SIMATIC S7-1200

G_ST80_XX_00469
WinCC Runtime Advanced single-user system

WinCC RT WinCC RT WinCC RT WinCC RT


Professional Professional Professional Professional
Client Client Client Client

Industrial Ethernet

WinCC RT
Professional
Server

PROFIBUS
G_ST80_XX_00471

SIMATIC S7-1500 SIMATIC S7-1500

WinCC Runtime Professional multi-user system with operable Server

Siemens ST 80 / ST PC 2016 3/25


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

Overview (continued)

OPC Client

WinCC RT
Professional

Industrial Ethernet

OPC Server

3 WinCC RT
Advanced

PROFIBUS

G_ST80_XX_00470
SIMATIC S7-300
SIMATIC S7-1200

OPC coupling

Ordering data Article No. Article No.

SIMATIC WinCC (TIA Portal) SIMATIC NET SOFTNET-IE S7 V12


Communication Software for S7 and S5-compatible
Communication via communication, incl. OPC server,
Industrial Ethernet TCP/IP PG/OP communication and NCM
PC, up to 64 connections, single
CP 1612 A2 6GK1161-2AA01 license for 1 installation, runtime
PCI card (32-bit) for connecting a software, software and electronic
programming device or PC to manual on CD-ROM, license key on
Industrial Ethernet USB stick, Class A
(10/100/1000 Mbps) Single license for 1 installation 6GK1704-1CW12-0AA0
with RJ45 connection via Upgrade package for 6GK1704-1CW00-3AE0
SOFTNET-S7 and SOFTNET PG. SIMATIC NET from Edition 2006
Software requirement: Upgrade package for 6GK1704-1CW00-3AE1
WinCC Runtime Advanced: SIMATIC NET V6.0, V6.1, V6.2 and
No further installation is required Edition 2005
(SOFTNET-S7)
SIMATIC NET SOFTNET-IE S7
WinCC Runtime Professional:
LEAN V12
SOFTNET-S7 Lean (maximum of
8 connections) or SOFTNET-S7 (included in the scope of delivery of
(maximum of 64 connections) must WinCC Runtime Professional)
be installed (SOFTNET-S7 Lean is Software for S7-compatible and
included in the scope of delivery of S5-compatible communication
WinCC Runtime Professional) incl. OPC server,
PG/OP communication and
NCM PC,
up to 8 connections, single license
for one installation of runtime
software, software and electronic
manual on CD-ROM, license key on
USB stick; Class A
Single license for 1 installation 6GK1704-1LW12-0AA0
Upgrade package for 6GK1704-1LW00-3AE0
SIMATIC NET from Edition 2006
Upgrade package for 6GK1704-1LW00-3AE1
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

3/26 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

Ordering data Article No. Article No.


CP 1613 A2 6GK1161-3AA01 CP 5613 A3 6GK1561-3AA02
PCI card (32-bit) for connecting a PCI Card (32-bit) for connecting a
PG/PC to Industrial Ethernet PC to PROFIBUS
(communications software must be (communications software must be
ordered separately) ordered separately)
SIMATIC NET HARDNET-IE S7 CP 5623 6GK1562-3AA00
V12 PCI Express X1 card (32-bit) for
Software for S7, connection of PG/PC to Industrial
open communication; OPC, Ethernet (communications software
PG/OP communication, project must be ordered separately)
software; up to 120 connections;
single license for one installation of S7-5613 Version 8.0 SP1 /
runtime software, software and Edition 2008 SP2 (V7.1)
electronic manual on DVD; Software for S7 communication
license key on USB stick; Class A incl. PG/OP protocol, FDL,
Single license for 1 installation 6GK1716-1CB12-0AA0 OPC server;
runtime software, software and
Upgrade package for SIMATIC 6GK1716-1CB00-3AE0 electronic manual on CD-ROM,
NET from Edition 2006
3
license key on USB stick, Class A
Upgrade package for 6GK1716-1CB00-3AE1
SIMATIC NET V6.0, V6.1, V6.2 and Version 8.0 SP1
Edition 2005 For (32-bit) Windows 7 Ultimate,
Professional; for CP 5613 A2,
CP 1623 6GK1162-3AA00 CP 5623 German/English
PCI Express X1 card (32-bit) for For (32-bit) Windows XP
connection of PG/PC to Industrial Professional, Windows 2003 Server,
Ethernet (communications software VISTA Ultimate/Business;
must be ordered separately) for CP 5613 A2, CP 5623
Communication via PROFIBUS German/English
Single license for 1 installation 6GK1713-5CB80-3AA0
USB A2 PC adapter 6GK1571-0BA00-0AA0
Upgrade package for 6GK1713-5CB00-3AE0
Can be used under Windows XP, SIMATIC NET from Edition 2006
Windows 7 32/64-bit
Upgrade package 6GK1713-5CB00-3AE1
CP 5612 6GK1561-2AA00 for SIMATIC NET V6.0, V6.1, V6.2
PCI card (32-bit) for connecting a and Edition 2005
PG/PC to PROFIBUS (communica-
tions software included in the
WinCC basic package)
CP 5622 6GK1562-2AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5622 MPI 6GK1562-2AM00
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
or MPI (communications software
included in the WinCC basic
package)
CP 5711 6GK1571-1AA00
USB adapter (USB V2.0) for
connecting a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC Basic
package)

Siemens ST 80 / ST PC 2016 3/27


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options

Overview
Options for SIMATIC Panels, SIMATIC WinCC Runtime SIMATIC WinCC Sm@rtServer
Advanced and SIMATIC WinCC Runtime Professional for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
SIMATIC WinCC Recipes Flexible solution for location-independent access to
for SIMATIC WinCC Runtime Advanced and HMI systems
SIMATIC WinCC Runtime Professional Remote maintenance of machines and plants via the
Generation and management of data records for machine or Internet/intranet
production data Reduced downtimes for machines and plants due to direct
Display or entry of data records via a configurable screen remote access
object or via process pictures distributed within the project Flexible solution for location-independent access to machines
Transmission of data records from or to the PLC and plants
Import/export of data records for further processing with other SIMATIC WinCC Server and SIMATIC WinCC Client
tools (e.g. MS Excel) for SIMATIC WinCC Runtime Professional
SIMATIC WinCC Logging For setting up a high-performance client-server system
for SIMATIC WinCC Runtime Advanced and
3 SIMATIC WinCC Runtime Professional
A number of coordinated HMI stations can be operated in a
single group with networked automation systems
Logging of alarms and process values Client/server solution:
Online evaluation of process value logs and alarm logs - One server supplies up to 32 connected clients with process
Evaluation of process value and alarm logs using standard MS and archive data, alarms, screens and reports.
tools such as Excel SIMATIC WinCC Redundancy
SIMATIC WinCC Audit for SIMATIC WinCC Runtime Professional
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced For configuring a high-performance, fail-safe client-server
Recording of operator actions in an audit trail system. One WinCC/Redundancy package is required for each
Electronic signature for important user actions relevant to redundant pair of servers.
production SIMATIC Information Server 2014
Audit supports users in meeting special quality requirements, for SIMATIC WinCC Runtime Professional
e.g. The SIMATIC Information Server 2014 is an open, Web-based
- Production plants requiring validation according to reporting system for interactive areas. Reports can be used in
FDA 21 CFR Part 11 Internet Explorer, for Excel, Word or PowerPoint, as well as for
- In respect of traceability according to EU 175/2002 Adobe Reader (pdf). The SIMATIC Information Server has
(EU directive) access to archived process values and messages, and can be
SIMATIC Logon used either directly in conjunction with WinCC / WinCC/RT
for SIMATIC Panels, SIMATIC WinCC Runtime Advanced Professional / PCS7 OS as well as with SIMATIC Process
and SIMATIC WinCC Runtime Professional Historian 2014.
Creates user administration on a central computer to which For more detailed information on the SIMATIC Information Server
one or more WinCC stations can be connected over Ethernet. and article numbers, see SCADA System SIMATIC WinCC.
With each logging-on/off of a user on one of the connected http://www.siemens.com/simatic-information-server
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon supports the user in combination with the
Audit option in meeting requirements in accordance with
FDA 21 CFR Part 11 and EU178.

3/28 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options

Overview (continued)
SIMATIC Process Historian 2014 SIMATIC WinCC WebNavigator
for SIMATIC WinCC Runtime Professional for SIMATIC WinCC Runtime Professional
The SIMATIC Process Historian 2014 is a powerful, long-term Operator control and monitoring of plants via the Internet or
archive server solution that stores the WinCC process values the in-house intranet/LAN
and messages in a central database. The system offers full Web Client permits the operator control and monitoring of a
scalability for performance and scope. It records and stores current WinCC Runtime Professional project via an Internet
data from one or more WinCC, WinCC/RT Professional and browser with ActiveX support
PCS 7 projects. The number of connected single stations,
servers, or redundant server pairs is unrestricted. SIMATIC SIMATIC WinCC DataMonitor
Process Historian is designed for use throughout your plant, and for SIMATIC WinCC Runtime Professional
is positioned below the corporate management level Display and analysis of current process states and historical
(ERP, MES). data on office PCs with standard tools
For more detailed information on the SIMATIC Process Historian Information can be individually compiled online during
and article numbers, see SCADA System SIMATIC WinCC. runtime via the Internet/intranet.
http:www.siemens.com/simatic-process-historian SIMATIC WinCC ControlDevelopment
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional 3
Expansion of the basic functionality with proprietary controls
Development of proprietary VB.net or C# controls for
integration in WinCC Runtime Advanced and WinCC Runtime
Professional
Overview of the individual options
Options WinCC RT Advanced WinCC RT Professional SIMATIC Panels
WinCC Recipes -
WinCC Logging -
WinCC Audit -
SIMATIC Logon
WinCC Sm@rtServer -
WinCC Server/WinCC Client - -
WinCC Redundancy - -
SIMATIC Information Server - -
SIMATIC Process Historian - -
WinCC WebNavigator - -
WinCC DataMonitor - -
WinCC ControlDevelopment -

Possible

Siemens ST 80 / ST PC 2016 3/29


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Recipes

Overview Function
Input of data records (e.g. operating parameters of a
machine, production data for a plastics machine) on the
HMI device as well as their storage and transfer to the control
Display or entry of data records via a configurable screen
object or via several process screens distributed within the
project
The data record elements are coupled with the process via a
direct tag connection
Transmission of data records from or to the controller
Powerful interfaces enable a synchronized data exchange
with the controller.
Storage of data records on local data carriers or on remote
data servers via networks
Logging of data records, e.g. as batch report/shift report

3 User-friendly and flexible management of data records by


powerful standard functions
Option for SIMATIC WinCC Runtime Advanced and
WinCC Runtime Professional for managing data records in The recipes and the associated data records are created using
recipes that contain related machine or production data a separate, user-friendly WinCC Engineering editor and data is
pre-assigned to them. A configurable table object is used for
The data in a data set can be transferred, for example, from displaying the data at runtime. Furthermore, the individual data
the control unit to the PLC to switch production to a different record elements can also be displayed directly based on stan-
product variant dard input/output fields across several process screens. In this
Licensing: way, the data in technological views can be presented clearly to
- SIMATIC Panels / Multi Panels / Comfort Panels: the operator.
No license is required. Import and export functions support the importing and exporting
- WinCC Runtime Advanced: of data via external applications (e.g. MS Excel).
One license is required per operator station
- WinCC Runtime Professional:
A license is only required on the server
(or single-user system).

Benefits
Generation and management of machine parameters and
production data on the basis of data records, and exchange
with the automation device, e.g. with the machine.
Clear tabular representation of the data elements with the aid
of a configurable screen object, or depiction in technological
relationships across several process screens.
Simple operator guidance through standard functions.
Export/import of data records for further processing with other
tools (e.g. MS Excel)

3/30 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Recipes

Technical specifications Ordering data Article No.

WinCC Recipes SIMATIC WinCC Recipes


for Runtime Advanced for Runtime Advanced 1)
The values specified are maximum Single license, 6AV2107-0JA00-0BB0
values license key only on USB stick
Number of recipes 999 as download 2) 6AV2107-0JA00-0BH0
1) Single license, license key
Number of elements per recipe 2000 download only; E-mail address
User data length in KB per data 256 required for the delivery
record SIMATIC WinCC Recipes + 6AV2107-0HA00-0BB0
Number of data records per recipe 5000 Logging for Runtime Advanced 1)
Single license,
1) When using arrays, each array element represents a recipe element license key only on USB stick

WinCC Recipes SIMATIC WinCC Recipes


for Runtime Professional for Runtime Professional 1)

The values specified are maximum Single license, 6AV2107-0JB00-0BB0

3
values license key only on USB stick

Number of recipes 1000 2) as download 2) 6AV2107-0JB00-0BH0


Single license, license key
Number of elements per recipe 1) 500 3)
download only; E-mail address
required for the delivery
User data length in KB per data 3000 3)
record 1) One license is required for each operator console. A license is not required
Number of data records per recipe 3000 2) for the engineering system for configuring the runtime option.
2) Current information and availability regarding the new delivery package
1)
When using arrays, each array element represents a recipe element can be found at: http://www.siemens.com/tia-online-software-delivery
2)
Limited by system resources.
3)
The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.

Siemens ST 80 / ST PC 2016 3/31


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Logging

Overview Application
Transfer of the logs for evaluation and long-term archiving
Detection of recurring error states
Optimization of maintenance cycles
Ensuring the quality standard
Quality assurance and checking the utilization of production
sequences
Documentation of process sequences

Function
Time-controlled as well as manual or process-controlled
swapping out of process data and alarms for long-term
archiving
During runtime, swapped out data are read in and selectively

3
analyzed using WinCC Runtime Professional
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
Option for SIMATIC WinCC Runtime Advanced and WinCC
facilitated by a read line.
Runtime Professional for logging process values and alarms
- Presentation and evaluation of archived alarms based on a
Logging of process values and alarms supports the acqui- configurable alarm view.
sition and processing of process data from an industrial plant - User-friendly navigation in the logs
or machine. Evaluation of the logged process data provides
External evaluation of the logs using MS standard tools
information about the operating states of the plant or machine
Various log types are supported: sequence and circular logs
Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels: Logging of process values and alarms on external,
No license is required. Windows-supported storage media
- WinCC Runtime Advanced: - SIMATIC Panels and WinCC Runtime Advanced:
One license is required per operator station CSV files, RDB files, Microsoft SQL Server via ODBC
- WinCC Runtime Professional: - WinCC Runtime Professional: Microsoft SQL Server 2005
500 Logging Tags are already included in the basic package Powerful standard functions permit user-friendly and flexible
The number of Logging Tags can be increased by means of utilization of the logs
additional licenses

Benefits
Alarm and process value logs enable predictive diagnostics,
which avoids downtimes
Early detection of danger and fault conditions
Increase of the product quality and the productivity thanks to
regular analysis of the alarm and process value logs

3/32 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Logging

Technical specifications Ordering data Article No.

WinCC Logging SIMATIC WinCC Logging


for Runtime Advanced for Runtime Advanced 1)
The values specified are maximum Single license, license key only on 6AV2107-0GA00-0BB0
values USB stick
Number of logs 100 as download 2) 6AV2107-0GA00-0BH0
Single license,
Archivable data Process values, alarms license key download only
Cyclical trigger for archiving process 1 s e-mail address required for the
values (variables) delivery

Max. number of entries per log 500.000 1) SIMATIC WinCC Recipes + 6AV2107-0HA00-0BB0
(incl. sequence log) Logging for Runtime Advanced 1)
Single license per option,
Log types Circular logs, license key only on USB stick
sequence logs (max. 400 per log)
SIMATIC WinCC Logging
Data storage format CSV (Comma Separated Variable), for Runtime Professional
RDB (Runtime Data Base), 1500 Logging Tags

3
Microsoft SQL database (database
not included in scope of delivery) Single license, 6AV2107-0GB00-0BB0
license key only on USB stick
1) Dependent on memory medium used
as download 2)
6AV2107-0GB00-0BH0
WinCC Logging Single license,
for Runtime Professional license key download only
e-mail address required for the
The values specified are maximum delivery
values
SIMATIC WinCC Logging
Number of logs per single-user 100 for Runtime Professional
station/server 5000 Logging Tags
Archivable data Process values, alarms Single license, 6AV2107-0GD00-0BB0
license key only on USB stick
Measured values per second, max. Server/single-user station:
5 000 per sec. as download 2) 6AV2107-0GD00-0BH0
2) Single license,
Log tags per single-user station/ 8.000 license key download only
server e-mail address required for the
Log types Circular log with and without long-term delivery
logging SIMATIC WinCC Logging for
Data storage format Microsoft SQL 2008 database Runtime Professional Powerpack
1500 -> 5000 LoggingTags
Single license, 6AV2107-2GD00-0BD0
license key only on USB stick
as download 2) 6AV2107-2GD00-0BJ0
Single license,
license key download only
e-mail address required for the
delivery
WinCC Logging Upgrade 6AV2107-4GX00-0BF0
for SIMATIC WinCC Archives V7.0
(10 licenses)
Single license per option,
license key only on USB stick
2) 1)
Dependent on the Logging PowerPack used for the log tags. 500 log tags One license is required for each operator console. A license is not required
are contained in the basis version. for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC 2016 3/33


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Audit

Overview Technical specifications


WinCC Audit
Storage location for Audit Trail when Plug-in Flash memory card or
used on the Panel via Ethernet in the higher-level PC
Storage location for Audit Trail when Local hard disk or
using WinCC Runtime Advanced via Ethernet in the higher-level PC
Execution platform
SIMATIC Panels Mobile Panel 277, TP/OP 277
SIMATIC Multi Panels MP 277, MP 377
SIMATIC Comfort Panels all
PC systems SIMATIC WinCC Runtime Advanced

Ordering data Article No.

3 SIMATIC WinCC Audit


for SIMATIC Panels
Option for SIMATIC WinCC Runtime Advanced as well as Single license, 6AV2107-0RP00-0BB0
SIMATIC Panels for recording operations in an audit trail, and license key only on USB stick
electronic signature
as download 1) 6AV2107-0RP00-0BH0
The audit trail is furnished with a security mechanism that Single license,
displays subsequent manipulations. license key download only
E-mail address required for the de-
A user-friendly configuration function, which is included as livery
standard in WinCC, is used to define the following:
SIMATIC WinCC Audit
- Which user actions should be recorded in the audit trail for Runtime Advanced 2)
during runtime
- Which important operator actions during execution time Single license, 6AV2107-0RA00-0BB0
require electronic signature/comments license key only on USB stick

Available for the following SIMATIC HMI systems: as download 1) 6AV2107-0RA00-0BH0


Single license,
- Comfort Panels license key download only
- Mobile Panels E-mail address required for the de-
- TP/OP 277 livery
- MP 277 1)
Current information and availability regarding the new delivery package
- MP 377 can be found at: http://www.siemens.com/tia-online-software-delivery
- WinCC Runtime Advanced 2)
The following license is also required: SIMATIC WinCC Logging for
Licensing: Runtime Advanced
- A license for SIMATIC WinCC Logging und SIMATIC WinCC
Audit is required for every operator control unit (panel or PC).

Benefits
Audit supports the user in meeting special quality require-
ments, e.g.
- Production plant requiring validation according to
21 CFR Part 11 FDA 1)
- In respect of traceability according to EU 175/2002 2)
The entries in the audit trail are uniquely assigned to users.
This means that responsibilities are clearly identifiable.
The audit trail, stored as a CSV file 3), can be checked via a
security mechanism to find out if subsequent changes have
been made.
For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.

1)
The FDA (Food and Drug Administration) is the American public health
body
2)
21 CFR Part 11- law on plant validation
3)
CSV Comma Separated Values

3/34 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
SIMATIC Logon

Overview Benefits
Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times.
Time-consuming multiple configurations for each individual
local station become unnecessary. Accordingly, users can be
easily configured from a central location.
All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.

Design
SIMATIC Logon for Panels and WinCC Runtime Advanced
SIMATIC Logon and SIMATIC Logon Remote Access are in-
Option for connecting SIMATIC Panels and PCs with stalled on a central station.
SIMATIC WinCC Runtime Advanced as well as WinCC
Runtime Professional to a central user administration. The following Runtime stations are connected to the central sta-
Creates user administration on a central computer to which
one or more panels or WinCC stations can be connected over
tion via the Ethernet network:
PCs with WinCC Runtime Advanced
3
Ethernet. SIMATIC Panels from the 177 series or higher
With each logging-on/off of a user on one of the connected (with Ethernet interface)
stations, SIMATIC Logon checks whether a user password has SIMATIC Mobile Panels from the 177 series or higher
been created and that the required privileges exist. (with Ethernet interface)
SIMATIC Logon for Panels and WinCC Runtime Advanced SIMATIC Multi Panels
All users of the SIMATIC Panels or WinCC Runtime Advanced SIMATIC Comfort Panels
stations can be managed plant-wide from a central location
SIMATIC Logon for WinCC Runtime Professional
Supports the user in combination with the Audit option in
meeting requirements in accordance with FDA 21 CFR Part 11 The SIMATIC Logon can be used for the central user manage-
and EU178. ment of several WinCC Runtime Professional stations. Operation
in a Windows Workgroup or even in a domain is possible.
Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for the connection of 3 panels or Function
WinCC Runtime Advanced stations to a central user adminis-
tration. Additional stations can be connected by using further Users receive a unique user ID, user name and password.
SIMATIC Logon Remote Access licenses (3-pack/10-pack). This information is encrypted and stored at a central point
(for SIMATIC Logon in the Windows user management). Func-
SIMATIC Logon for WinCC Runtime Professional tions such as changing the password, automatic log-off after a
All users of WinCC Runtime Professional can be managed predefined time and lockout after several incorrect entries of a
plant-wide from a central location. password ensure maximum security of operation. In addition,
SIMATIC Logon allows setting up new users online, plant-wide
The central user management with SL utilizes Windows and across applications, or blocking of existing users.
mechanisms and must be installed on all participating WinCC SIMATIC Logon also supports electronic signature.
Runtime Professional stations.
Licensing
SIMATIC Logon (basic license) is included in the basic
package of WinCC Runtime Professional

Siemens ST 80 / ST PC 2016 3/35


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
SIMATIC Logon

Ordering data Article No.

SIMATIC Logon V1.5 6ES7658-7BX51-0YA0


Basic license 1)
For panels or WinCC Runtime
Advanced stations, the
corresponding number of additional
SIMATIC Logon Remote Access
licenses is required.
No SIMATIC Logon Remote Access
licenses are required for
WinCC Runtime Professional
SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0
SIMATIC Logon Remote Access 6ES7658-7BA00-2YB0
(3 clients)
Remote Access for 3 clients;
Single License for 3 SIMATIC Logon
Remote Access clients;

3
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
SIMATIC Logon Remote Access 6ES7658-7BB00-2YB0
(10 clients)
Remote Access for 10 clients;
Single License for 10 SIMATIC
Logon Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
1)
SIMATIC Logon V1.5 included in scope of supply of WinCC Runtime
Professional.

3/36 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

Overview

Sm@rtServer Sm@rtClient

Master station Operator station 1 Operator station 2 Operator station n

...

G_ST80_XX_00071
Industrial Ethernet

Option for SIMATIC WinCC Runtime Advanced plus SIMATIC Licensing:


Panels for communication between various SIMATIC HMI The "SIMATIC WinCC Sm@rtServer for Panel" or
systems. "SIMATIC WinCC Sm@rtServer for WinCC Runtime Advanced"
Available for the following SIMATIC HMI systems: license must be installed on the server HMI device. A license
- Comfort Panels is not required for the engineering system for configuring the
- Mobile Panel 177 PN, Mobile Panel 277 runtime option.
- TP 177B PN/DP, OP 177B PN/DP Note:
- TP 277, OP 277
- MP 177, MP 277, MP 377 When accessing the operator stations via the Sm@rtServer
- WinCC Runtime Advanced option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
A SIMATIC HMI system can be used to control or monitor safe operation of the system.
another system remotely; entry level for client/server
configurations for distributed operator stations or for solutions You will find more information on the topic of Industrial Security
with head end or control room on the Internet at:
Local operation, visualization and data processing are as http://www.siemens.com/industrialsecurity
possible as plant-wide access to information. Integrated infor-
mation flows ensure an overview of the status of all processes.

Benefits
Flexible solution for remote access to HMI systems
Quick elimination of malfunctions or downtimes thus
increasing the productivity through global access to
machines/plants by the service and maintenance personnel.
Avoidance of on-site service calls.

Siemens ST 80 / ST PC 2016 3/37


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

Application
Operator control and monitoring of machines covering large Remote maintenance and servicing of machines/plants over
areas with several operator stations by one operator. the Internet/Intranet
Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)

Sm@rtServer Sm@rtClient

Master station Operator station 1 Operator station 2 Operator station n

...

G_ST80_XX_00071
Industrial Ethernet

Application of the Sm@rtClient concept: Coordinated operation of several operator stations

Master Control Station Sm@rtClient display

Industrial Ethernet

Server 1 Server 2 Server 3 Server 4

Sm@rtServer Sm@rtServer Sm@rtServer Sm@rtServer

PROFIBUS
G_ST80_XX_00072

Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station

3/38 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

Application (continued) Function


Coordinated operation of several operator stations:
The HMI application and communication with the controller
takes place via the master station. "Sm@rtClients" can be
TCP/IP
activated from here in the case of machines/plants with larger
ISDN/DSL
dimensions which require a larger number of HMI devices.
Engineering Station Modem/Router The Sm@rtClients are then provided with access to the master
PG/PC station and thus to the process. Access procedures guarantee
that only one operator system can actively access the process
at any given time.
Internet Embedded in process screens, a configurable screen object
(Sm@rtClient display) represents the screen of the relevant
HMI system (Sm@rtServer)
Powerful standard functions permit user-friendly and flexible
ISDN/DSL operation of the display
Modem/Router
Remote control of an operating station:
The HMI application and communication with the controller 3
G_ST80_XX_00073
Industrial Ethernet takes place via the HMI system. Using the Sm@rtServer, the
HMI systems in the machines/systems can be serviced
remotely. An access process ensures that only one operator
(either locally at the machine or remotely via Internet Explorer)
can actively access the process at one time.
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet accessing an HMI system.

Case 2:
Operator control and monitoring
using the Internet/Intranet with
access to the complete device;
Engineering Station softkeys and function keys
PC/PG
Case 1:
Operator control and monitoring
using the
Microsoft Internet Explorer

Industrial Ethernet
G_ST80_XX_00076

PROFIBUS

Remote operator control and monitoring of SIMATIC HMI systems using


Industrial Ethernet and/or via the Intranet/Internet

Siemens ST 80 / ST PC 2016 3/39


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

Technical specifications Ordering data Article No.

WinCC Sm@rtServer WinCC Sm@rtServer


for SIMATIC Panels 1)
The values specified are maximum
values Single license, 6AV2107-0CP00-0BB0
license key only on USB stick
Execution platform
as download 2) 6AV2107-0CP00-0BH0
SIMATIC Comfort Panels all Single license,
SIMATIC Panels Mobile Panel 177 PN, license key download only
Mobile Panel 277, E-mail address required for the
TP/OP 177B PN/DP, delivery
TP/OP 277 WinCC Sm@rtServer
SIMATIC Multi Panels MP 177, for Runtime Advanced 1)
MP 277, Single license, 6AV2107-0CA00-0BB0
MP 377 license key only on USB stick
PC systems SIMATIC WinCC Runtime Advanced as download 2) 6AV2107-0CA00-0BH0
Number of Sm@rtClients Single license,
that can simultaneously connect license key download only
3 to a Sm@rtServer
Comfort Panel 2 clients for 4" devices
E-mail address required for the
delivery

as Sm@rtServer 3 clients for 7", 9", 12" and 15" devices 1) The license must be installed on the Sm@rtServer HMI device. A license is
2 clients for 19" devices not required for the engineering system for configuring the runtime option.
1 client for 22" devices 2) Current information and availability regarding the new delivery package
Mobile Panel 177 PN, 2 clients can be found at: http://www.siemens.com/tia-online-software-delivery
TP/OP 177B PN/DP,
MP 177 as Sm@rtServer
Mobile Panel 277, 3 clients for 6" devices
TP/OP 277, 2 clients for 8" and 10" devices
MP 277 as Sm@rtServer
MP 377 as Sm@rtServer 3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
WinCC Runtime Advanced as 5 clients
Sm@rtServer

3/40 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client

Overview

WinCC RT WinCC RT WinCC RT WinCC RT


Professional Professional Professional Professional
Client Client Client Client

Industrial Ethernet

WinCC RT

3
Professional
Server

PROFIBUS

G_ST80_XX_00471
SIMATIC S7-1500 SIMATIC S7-1500

WinCC TIA RT Professional - Multi-user system with operable server

Option for SIMATIC WinCC Runtime Professional, which Client/server solution: One server can supply up to
permits the configuration of a powerful client/server system 32 connected clients with process and archive data, alarms,
One of the following operating systems must be available to screens and reports
install the option on the server: Windows Server 2003 R2 SP2, - Requirement: Network connection (TCP/IP) between the
Windows Server 2008 SP2 or Windows XP Professional. When server PC and the connected clients
using Windows XP Professional, max. 3 clients can be Licensing:
connected. - A WinCC Runtime Professional license on the server with the
A number of coordinated OCM stations can be operated appropriate number of PowerTags and the "WinCC Server for
in a single group with networked automation systems RT Professional" license.
- The "WinCC Client for RT Professional" license on the clients.

Benefits
Integrated scalability from the single-user system to the
client/server solution
Considerably expanded quantity structure, relieves the load
on the individual servers, and thus better performance
through the distribution of the overall application or of the
tasks among several servers

Siemens ST 80 / ST PC 2016 3/41


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client

Application Ordering data Article No.


In a complex plant, WinCC Runtime Professional can be SIMATIC WinCC server
configured as a distributed system depending on the for Runtime Professional
requirements: Single license, 6AV2107-0EB00-0BB0
Functional distribution (e.g. alarm server, log server, etc.), or license key only on USB stick
Distribution corresponding to the physical plant structure as download 1) 6AV2107-0EB00-0BH0
(e.g. body-in-white, paint shop, etc.). Single license,
license key download only,
email address required for delivery
Function SIMATIC WinCC Client for
Runtime Professional V13 SP1
All process data of a WinCC project is stored in different Runtime
databases, e.g. alarms, trend values, etc. These Runtime data- Single license, 6AV2107-0DB03-0AA0
bases are located on a central computer, the WinCC Server, license key on USB stick,
software and documentation
instead on each HMI device. The operator stations, i.e. the on DVD
WinCC Clients, then access the WinCC Server.
as download 1) 6AV2107-0DB03-0AH0
WinCC Clients and WinCC Server are independent systems. Single license,
3 You can also connect WinCC Clients subsequently. Alternatively,
you can activate and deactivate a project from a WinCC Client.
software and license key
download.
email address required for the
delivery
SIMATIC WinCC Client for 6AV2107-0DB13-0AA0
Runtime Professional ASIA
V13 SP1
Single license,
license key on USB stick,
software and documentation
on DVD
1) Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
A license is not required for the engineering system for
configuring the runtime option.

3/42 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC Redundancy

Overview Ordering data Article No.

Option for SIMATIC WinCC (TIA Portal), supporting the parallel SIMATIC WinCC Redundancy
operation of two interfaced WinCC single-user systems or pro- for Runtime Professional
cess data servers for mutual monitoring Single license for 2 installations, 6AV2107-0FB00-0BB0
If one of the two server PCs or one of the two WinCC stations license key on USB stick,
software and documentation
fails, the second one will take over control of the entire system. on DVD
Once the failed server or station is restored to operation, the con-
tents of all the message and process value archives are copied as download 1) 6AV2107-0FB00-0BH0
Single license for 2 installations,
to it. license key download only,
One WinCC Redundancy package is required for each e-mail address required for
delivery
redundant pair of servers.
1)
Current information and availability regarding the new delivery package
Benefits can be found at: http://www.siemens.com/tia-online-software-delivery

Increased system availability with gap-free data integrity A license is not required for the engineering system for
configuring the runtime option.
Automatic switchover of the client when a server fails or the
communication to the server fails
Continuous operation and visualization through automatic
3
switchover of the clients to the intact server
Automatic synchronization of all archives in the background
after a fault is cleared

Function
Normally, two WinCC stations or process data servers run in par-
allel. Each station has its own process connection and its own
data archives. WinCC Redundancy ensures automatic matching
of system and user archive data.
If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
visualization and operation on every operator station.
When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automat-
ically matched with the partner. This process runs in the back-
ground and does not affect plant continuity. Once this is com-
plete, two equivalent servers/stations will be available again.
Communication with the SIMATIC S7 PLC can also be config-
ured with redundancy (an H Series SIMATIC S7 is required) by
plugging in two communication modules and configuring two
communication paths (S7-REDCONNECT software package).
The use of failsafe H Series SIMATIC S7 PLCs can, if required,
further increase availability at control level.

Siemens ST 80 / ST PC 2016 3/43


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

Overview

Web client/ Web client/


WinCC DataMonitor DataMonitor
SCADA clients on www on www

LAN

WinCC server
3 + WebNavigator/
DataMonitor
server

PROFINET

G_ST80_XX_00556
PROFIBUS
S7-1500 S7-1500 S7-300

Option for SIMATIC WinCC Runtime Professional for operating Note:


and monitoring plants over the Internet, company Intranet or
LAN. When accessing the operator stations via the WinCC
WebNavigator option, suitable protective measures (including
Configuration from: IT security such as network segmentation) should be taken in
- A web server with SIMATIC WinCC Runtime Professional as order to ensure safe operation of the system.
single-user or server version and a web client that permits
operator control and monitoring of a current WinCC Runtime You will find more information on the topic of Industrial Security
Professional project using the Internet Explorer. on the Internet at:
Licensing: http://www.siemens.com/industrialsecurity
- A license is required for using the Web server.
- Server-based licenses are available for access to the web
server by 3, 10, 25 or 50 clients.
- Client-based licenses are available for guaranteed access to
the web server (Diagnostics Client)

3/44 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

Benefits Application
Operator control and monitoring across long distances and on In addition to the typical use of the WebNavigator in WANs
different platforms (PC, local panel, mobile PDA) (Wide Area Networks), the WebNavigator can also be used to
Large configurations with up to 50 operator stations implement especially low-cost applications. This especially
Fast update rates due to event-driven communication includes applications that have a pronounced distributed struc-
ture (water/wastewater, oil and gas), or in which access to
Optimally tailored clients for operating and monitoring, process information is only sporadic (building management).
analysis, service and diagnostics
The WebNavigator also permits vertical integration, i.e. a net-
Acceptance of configuration data for the web, generally worked IT landscape with integrated data flow between the plan-
without changes ning and operating level of a company. Only a standard browser
Minimum maintenance costs due to central software is required for direct access to current process information.
administration
In addition to the standard WebNavigator licensing, there is the
High security standards and availability "Diagnostics Client" with identical functionality but different li-
- Support for commonly used security mechanisms (routers, censing. It is especially suitable for the following applications:
firewalls, proxy servers)
- WinCC access authorizations and user administration Remote diagnostics/operation of several unmanned WinCC
Runtime Professional stations
Support of Microsoft Internet Explorer, including "tabbed
browsing". A new license is not required for separate tabs. Central control rooms that monitor several web servers via one
user interface
3
With the WinCC Web Viewer (WinCC Viewer RT), the process
screens can be displayed on the web client independently of Maintenance personnel who require guaranteed access to the
the Internet Explorer. Settings for the client are made on the server at any time, regardless of the number of users already
client itself. The WinCC Web Viewer can also be used in logged on to the server. On the server side, only one WebNav-
conjunction with the MS Terminal Service. igator Diagnostics Server license or, alternatively, one
Standard WebNavigator license is required.
The SIMATIC WinCC WebNavigator can also be operated in
"view only" mode and is thus used as tool for monitoring and
navigating using Internet Explorer or WinCC Web Viewer
(WinCC Viewer RT).
Web server logins and logouts are recorded in the alarm and
audit log.
There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. No additional WebNavigator license is required for
the gadget. The WebNavigator server can be selected directly
via the gadget.
Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Highlights:
Multiple Web servers can be accessed from a single Web
client
User-friendly services and tools for distributing customized
objects (controls, files) to web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-web/server navigation.
Both Internet Explorer and the supplied, browser-independent
WinCC Web Viewer (WinCC Viewer RT) can be used as a front
end
Access to WebNavigator Server of the WinCC V7.x series.

Siemens ST 80 / ST PC 2016 3/45


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

Design Hybrid configuration


System requirements: WinCC WebNavigator Server V12
Licenses for the WebNavigator
Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
The WebNavigator Client software can be installed as many Ultimate (max. 3 Clients)
times as required without the need for a license. Windows XP Professional Service Pack 3 (max. 3 clients)
Server-based licensing Windows Server 2003 SP2
- A license is required for using the WebNavigator Server.
- Licenses are available for simultaneous access to the Web Windows Server 2008 SP2 32-bit
server by 3, 10, 25 or 50 clients. Windows Server 2008 R2 SP1 64-bit
Diagnose Client licensing Internet Explorer V7.0, V8.0, V9.0
- For cost-optimized access by one or a small number of Microsoft SQL Server 2008 R2 SP1 32-bit (included in the
WebNavigator clients to numerous Web servers (e.g. for WinCC product delivery)
diagnostic purposes). This client license provides
guaranteed access to Web servers at any time. In respect of WinCC Basic System V12
function there is no difference compared with regular System requirements: WinCC WebNavigator Client V12
WebNavigator clients and the two can be mixed.
Internet Explorer 7, IE 8, IE9

3 WebNavigator Clients are capable of accessing several different


Web Servers.
System requirements: WinCC WebNavigator Server V11
Windows 7 (32-bit) Business, Enterprise and Ultimate
Thin client solutions (max. 3 clients)
The WebNavigator can also run under Windows Server 2003 or Windows XP Professional Service Pack 2 (max. 3 clients)
Windows Server 2008 terminal services. A Windows Server 2003 Windows Server 2003 SP2 and Windows Server R2 SP2
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients Windows Server 2008
as visualization stations to WinCC Runtime Professional, Internet Explorer 7 as well as Internet Explorer 8
for example. Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
For this purpose, the Windows terminal services must be WinCC Runtime Professional V11
installed on the PC on which the Web Client is installed.
A Windows Server 2003 or Windows Server 2008 (or higher) System requirements: WinCC WebNavigator Client V11
operating system is required. Up to 25 thin clients can be Internet Explorer 7 as well as Internet Explorer 8
connected to one terminal server.
Applications: Function
Mobile devices WinCC Professional makes setting up and configuring a Web-
Handhelds Navigator server very easy. WinCC process screens to be visu-
alized via the Internet are created as usual in WinCC Profes-
Rugged on-site visualizations sional and the web access is activated via a process screen
option. To display WinCC process screens on the web client, the
Microsoft Internet Explorer or browser is used independent of
the supplied WinCC Web Viewer (WinCC Viewer RT).
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the sys-
tem according to the configured access rights. The WebNaviga-
tor supports all standard security mechanisms that can be used
for applications on the Internet, e.g. routers, firewalls and proxy
servers.

3/46 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

Ordering data Article No. Article No.

SIMATIC WinCC WebNavigator WinCC WebNavigator


for Runtime Professional (WinCC V13 or higher)
Single license, Standard scope of delivery
license key only on USB stick
3 clients, runtime software 6AV2107-0KD00-0BB0 SIMATIC WinCC WebNavigator
10 clients 6AV2107-0KF00-0BB0 for Runtime Professional
25 clients 6AV2107-0KH00-0BB0 1 client 6AV2107-0KB00-0BB0
50 clients 6AV2107-0KK00-0BB0 5 clients 6AV2107-0KE00-0BB0
100 clients 6AV2107-0KM00-0BB0 SIMATIC WinCC WebNavigator
150 clients 6AV2107-0KP00-0BB0 for Runtime Professional
Powerpack
SIMATIC WinCC WebNavigator 1 -> 3 clients 6AV2107-2KD00-0BD0
for Runtime Professional
Powerpacks 3 -> 5 clients 6AV2107-2KE00-0BD0
Single license, 5 -> 10 clients 6AV2107-2KG00-0BD0
license key only on USB stick as download
From 3 to 10 clients 6AV2107-2KF00-0BD0
SIMATIC WinCC WebNavigator
From 10 to 25 clients
From 25 to 50 clients
6AV2107-2KH00-0BD0
6AV2107-2KK00-0BD0
for Runtime Professional
1 client 6AV2107-0KB00-0BH0
3
From 50 to 100 clients 6AV2107-2KM00-0BD0 5 clients 6AV2107-0KE00-0BH0
From 100 to 150 clients 6AV2107-2KP00-0BD0
SIMATIC WinCC WebNavigator
SIMATIC WinCC WebNavigator for Runtime Professional
Diagnose Server/Client Powerpack
Single license, 1 -> 3 clients 6AV2107-2KD00-0BJ0
license key only on USB stick 3 -> 5 clients 6AV2107-2KE00-0BJ0
WinCC WebDiagnostics Server for 6AV2107-0KR00-0BB0 5 -> 10 clients 6AV2107-2KG00-0BJ0
Runtime Professional,
Runtime software
WinCC WebDiagnostics Client for 6AV2107-0KT00-0BB0
Runtime Professional,
Runtime software
as download 1)
WinCC WebNavigator
for Runtime Professional
Single license,
license key download only,
e-mail address required for the
delivery
3 clients 6AV2107-0KD00-0BH0
10 clients 6AV2107-0KF00-0BH0
25 clients 6AV2107-0KH00-0BH0
50 clients 6AV2107-0KK00-0BH0
100 clients 6AV2107-0KM00-0BH0
150 clients 6AV2107-0KP00-0BH0
WinCC WebNavigator for
Runtime Professional
Powerpacks
Single license,
license key download only,
e-mail address required for the
delivery
3 to 10 clients 6AV2107-2KF00-0BJ0
10 to 25 clients 6AV2107-2KH00-0BJ0
25 to 50 clients 6AV2107-2KK00-0BJ0
50 to 100 clients 6AV2107-2KM00-0BJ0
100 to 150 clients 6AV2107-2KP00-0BJ0
WinCC WebNavigator
Diagnostics Server/Client
Single license,
license key download only,
e-mail address required for the
delivery
WinCC Web Diagnostics Server 6AV2107-0KR00-0BH0
for Runtime Professional
WinCC Web Diagnostics Client 6AV2107-0KT00-0BH0
for Runtime Professional
1) Current information and availability regarding the new type of delivery can
be found at:http://www.siemens.com/tia-online-software-delivery
A license is not required for the engineering system for
configuring the runtime option.

Siemens ST 80 / ST PC 2016 3/47


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

Overview

Web client/ Web client/


WinCC DataMonitor DataMonitor
SCADA clients on www on www

LAN

WinCC server
3 + WebNavigator/
DataMonitor
server

PROFINET

G_ST80_XX_00556
PROFIBUS
S7-1500 S7-1500 S7-300

WinCC TIA WebNavigator

The WinCC DataMonitor is used for displaying and evaluating DataMonitor does not require manual client installation
current process states and historical data on office PCs using because it loads the required components from the
standard tools such as Microsoft Internet Explorer or Microsoft DataMonitor server
Excel. In doing so, the DataMonitor client is supplied by a Web There is no installation required on the client for the Webcenter
server with current and historic process data and alarms. All and Trends and Alarms functions
staff ranging from machine operators to corporate managers
can use the DataMonitor to obtain information. Licensing:
- Licenses for access by 1, 3, 10, 25, or 50 DataMonitor clients
DataMonitor is a suite of Internet-capable tools: are available
- Process screens - Any combination of DataMonitor and WebNavigator licenses
Tool exclusively for monitoring and navigating via WinCC can be used in an application
Runtime Professional screens using the WinCC Web Viewer
(WinCCViewerRT) in the "view only" mode Note:
- Excel Workbooks When accessing the operator stations via the
Logging tool that integrates WinCC Runtime Professional WinCC DataMonitor option, suitable protective measures
Archive and online values into Microsoft Excel and supports (including IT security such as network segmentation) should be
online analysis taken in order to ensure safe operation of the system.
- Published Reports
Event or time-driven implementation of Excel or PDF reports You will find more information on the topic of Industrial Security
for the output of process data and analysis results on the Internet at:
- Webcenter
Individual configuration of Internet pages and summary of http://www.siemens.com/industrialsecurity
information within a portal with reference to WinCC Runtime
Professional applications
- Trends and Alarms
(tables and graphs) are preconfigured Webcenter pages

3/48 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

Benefits Function
Information can be compiled online individually during All tools are fully Internet-compatible and, therefore, support
runtime via the Internet/Intranet. access via any type of connection (LAN, GSM, radio, modem,
Efficiently monitor and analyze production lines. Internet, etc.).
- Display and evaluation of current process states and All popular security mechanisms such as login/password,
historical data on remote office PCs with standard tools such firewalls, encryption, etc. are supported.
as Microsoft Internet Explorer or Excel. Users can combine the available tools at will. Licensing only
- Easy access to production data via the Intranet or Internet takes into account simultaneous access to one Web server.
- Quick ascertainment of the production situation
For display purposes, screens from the WinCC project can be
Easily collect and distribute information. used or special overview displays configured. Animations,
- Automated report creation scripts, navigation and access rights remain valid.
- No additional configuration effort through direct use of
screens from the WinCC project The WinCC DataMonitor has purely a display function
- No training required for standard products Company-wide Excel reports, which contain historical and
- Easy exchange of configuration data current process values, can be stored centrally for general
Substantiate decisions with reports. access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
3
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics) online. Plot and tabular representation are supported for
- Display bottlenecks transparently archive data already swapped out.
- Individual views for user and situation Data can be automatically entered into created report
- Relative and absolute timeframe for information generation templates and distributed by e-mail.
View production status anywhere and anytime. Pre-made elements make the assembly of individual web
- Individual views of information in production pages easier for evaluating information.
- View the process and system operation Individual information compilation on one or more Internet
- Historical data can be compiled online individually pages with the option of branching to other detail pages.
Highlights: Pre-made Internet pages for trend and alarm display enable
With the Webcenter function, WinCC Runtime Professional an ad-hoc entry to Internet data evaluation.
archive tags can be accessed without changing the configu- An higher-level navigation feature provides a common
ration system. framework for the various tools.
Dedicated Internet pages can be created for displaying data Enhanced user management for WebCenter in order to assign
with the Webcenter. For this purpose, the following tools, individual Internet pages and created reports to specific user
which can be integrated in the Internet sites, are available. groups
- Bar chart, pie chart, trend curve display A search function simplifies the management of connections
- Process value table and statistics functions for the process to the WinCC server
values
- Alarms, hit list for alarms Swapped out archives can be connected and evaluated in the
- Message text display for individual message texts, message DataMonitor WebCenter.
display, selection list of created reports, Excel reports created offline can be loaded onto the
- Links to internal and external pages DataMonitor server and are thus made available to selected
- Display of graphics in jpg format user groups or for automatic distribution.
- Representation of the WinCC Runtime Professional process
screens converted into jpg
The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
Reports generated with Excel or with WinCC Professional can
be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
Connections to WinCC Runtime Professional and to swapped
out archives can be established
Support of Microsoft Internet Explorer version, including
"tabbed browsing".

Siemens ST 80 / ST PC 2016 3/49


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

Ordering data Article No. Article No.

SIMATIC WinCC DataMonitor as download 1)


for Runtime Professional
SIMATIC WinCC DataMonitor
Single license, for Runtime Professional
license key only on USB stick
Single license,
1 client 6AV2107-0LB00-0BB0 license key download only,
3 clients 6AV2107-0LD00-0BB0 e-mail address required for the
10 clients 6AV2107-0LF00-0BB0 delivery
25 clients 6AV2107-0LH00-0BB0 1 client 6AV2107-0LB00-0BH0
50 clients 6AV2107-0LK00-0BB0 3 clients 6AV2107-0LD00-0BH0
SIMATIC WinCC DataMonitor 10 clients 6AV2107-0LF00-0BH0
for Runtime Professional 25 clients 6AV2107-0LH00-0BH0
Powerpacks 50 clients 6AV2107-0LK00-0BH0
Single license, SIMATIC WinCC DataMonitor
license key only on USB stick for Runtime Professional
From 1 to 3 Clients 6AV2107-2LD00-0BD0 Powerpacks
From 3 to 10 Clients 6AV2107-2LF00-0BD0 Single license,

3 From 10 to 25 Clients
From 25 to 50 Clients
6AV2107-2LH00-0BD0
6AV2107-2LK00-0BD0
license key download only,
e-mail address required for the
delivery
From 1 to 3 clients 6AV2107-2LD00-0BJ0
From 3 to 10 clients 6AV2107-2LF00-0BJ0
From 10 to 25 clients 6AV2107-2LH00-0BJ0
From 25 to 50 clients 6AV2107-2LK00-0BJ0
1) Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
A license is not required for the engineering system for
configuring the runtime option.

3/50 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) options
WinCC ControlDevelopment

Overview Ordering data Article No.

You use the ControlDevelopment option to create your own WinCC ControlDevelopment V13
.net controls for controlling and monitoring processes. You can Runtime license, single license, 6AV2107-0TA03-0DA8
use the controls in screens for WinCC Runtime Advanced and software and documentation
WinCC Runtime Professional. You create the controls based on on CD
the standard controls from Visual Studio 2005/2008 Professional Runtime software, single license, 6AV2107-0TA03-0DG8
.net. software download
(e-mail address required for the
Application examples delivery) 1)
Special trend views 1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Own recipe managements
Complex display objects
More information
Benefits Further information can be found in the Internet at:
The ControlDevelopment option enables user-specific software http://www.siemens.com/tia-portal

3
solutions based on a proven building block principle:
Lower development overhead by using standards
(Visual Studio 2005/2008 Professional .net)
Very short "Time-to-Market" resulting in a competitive
advantage
Utilization of tried components and proven industrial
functionality
The development of proprietary controls for WinCC Runtime
Advanced and WinCC Runtime Professional does not require
expensive, special hardware.

Siemens ST 80 / ST PC 2016 3/51


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC B.Data

Overview
Software for energy management SIMATIC B.Data V6.0 SP1 Energy Management System
SIMATIC offers numerous reasons for corporate energy man- SIMATIC B.Data is a modular, cross-sector energy management
agement in industrial plants. However, there is one in particular: system for industrial firms.
It makes an important contribution towards improving plant pro-
ductivity. This results in enhanced competitiveness. Energy
management with SIMATIC makes energy flows transparent in
production plants. This supports the analysis and derivation of
energy saving potential.
The result: Permanently increased efficiency, higher productivity
and an improved cost situation.

Energy management Company portal

3 B.Data Energy planning and procurement Energy controlling Monitoring and reporting

Energy purchase Emission Connection of external systems


Purchase support CO2 emission monitoring Facility management
Scenario calculator Wastewater disposal ERP (e.g. SAP R/3)
Maintenance management

Forecast Energy accounting


Energy forecast Cost center allocation
Budget planning Evaluation/invoicing
Energy reporting system

Energy schedule Energy and material balance Analysis and reporting


Workflow system
Energy purchase schedule KPI calculation Intranet/Internet viewer
Specifications for Load Production allocation
management

WinCC Fault/alarm management Operation and control system Load management


Alarms/messages Central detection Load shedding
Remote alarms (text message) Plant visualization Load control
Data processing and archiving

G_ST80_XX_00379
Automation Process
field level Interfaces to lower-level systems Meters/ control/ PLCs Circuit- Mobile data
measuring building breakers acquisition
devices management
sytems

3/52 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC B.Data

Benefits SIMATIC B.Data Software Update Service (SUS)


For each B.Data System there is a corresponding SUS (Software
The option SIMATIC B.Data forms the basis of a cost-effective Update Service) which is dependent on the number of tags.
energy management system for reducing energy costs and
increasing energy efficiency, and it confers the following imme- The SUS is valid for 1 year. The contract is automatically
diate benefits: extended by 1 more year unless canceled 3 months prior to
expiration.
It creates company-wide transparency, thanks to continuous
energy balancing and materials balancing for the power SIMATIC B.Data V6 expansions
generation systems and loads
The scope of B.Data can be extended by purchasing add-on
It allows energy costs to be allocated according to the costs- packages:
by-cause principle and permits transfer to the billing system
(e.g. SAP R/3 CO) B.Data Web Client
It generates characteristic values for well-informed sugges- B.Data Client
tions for increasing the efficiency of power generation systems B.Data Acquisition Component
and loads B.Data Forecasting and Planning
It provides planning reliability thanks to production-related
load and demand forecasts Function
It supports purchasing with cost-optimized energy
procurement Acquisition and pre-processing of energy and operating
3
It fulfills the legal obligations for monitoring and reporting on data
greenhouse gas emissions (CO2 emissions) In addition to an interface to WinCC, SIMATIC B.Data also
It relieves personnel of extra work through automatically offers the latest interface standards such as OPC DA,
updating internal and external energy reports OPC HDA, MODBUS TCP, ODBC, ASCII or XML
It supports customers in the continuous improvement of Preprocessing of energy data in a real-time calculation core
energy efficiency (e.g. ISO 50001) by integrated project that can be freely modeled including a formula editor for
management for energy efficiency measures defining and configuring new calculation functions (heat
calculations for boilers, quality for cogeneration plants, etc.)
Design B.Data Mobile for mobile recording of energy data including
route planning for meter reading operations
SIMATIC B.Data V6.0 SP1 Management and analysis of energy data
SIMATIC B.Data is available in Professional and Enterprise Automatic plausibility check and generation of simulated
editions: values
Professional Long-term archive with versioning, compression and consoli-
- Incl. 50 tags, 1 B.Data acquisition component, dation functions
1 B.Data Client, 1 Web Client Measured value editor for entering and processing energy
- Can be dynamically expanded with Tag Packages and operating values
(50, 100, 250, 500, 1 000, 5 000)
Trender for presenting up-to-date (online) and historical load
- Reporting, trender, dashboards, document management,
curves (trends), also for setpoint/actual value analyses
matrix, KPI, profile
- Recommended for systems with up to around 10 000 tags Energy management dashboards for creating cross-company
- May only be operated on a server with a maximum of transparency through visualization of performance indicators
4 processor sockets or on 2 4 servers as a Real Application and display of Sankey diagrams.
Cluster (RAC) with a maximum total of 4 processor sockets
Enterprise
- Available in versions for 30 000 tags and 60 000 tags
- Incl. 1 B.Data acquisition component, 1 B.Data Client,
20 Web Clients
- Database designed for the higher performance range
- Reporting, trender, dashboards, document management,
matrix, KPI, profile
- Recommended for systems with more than 10 000 tags
- No restrictions regarding processor sockets

B.Data - Full Client

Siemens ST 80 / ST PC 2016 3/53


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC B.Data

Function (continued) Energy reporting


Generation of energy schedules for registering with the
Energy and material balance energy suppliers. Energy reporting
Freely parameterizable balancing of the energy flows of various Freely parameterizable report generator for creating
media such as electricity, heat, gas, steam, and emissions balances, protocols, shift logs, bills
(CO2) in the B.Data Plant Explorer Fully automated reporting with task management, e-mail
Calculation of characteristic values (KPIs, efficiency coeffi- dispatch and document management
cients, etc.) with direct reference to production (batches, B.Data Intranet/Internet viewer (web client) for company-wide
quantities, etc.). viewing of reports and results
Information about discrepancies from specified parameters
through KPI warning system

Technical specifications
SIMATIC B.Data V6.0 SP1
Operating system Windows Server 2008 R2

3 (German/English)
Windows Server 2012 R2
(German/English)
Windows 7 Professional/Ultimate SP1
(German/English)
Windows 8.1 Pro/Enterprise 64-bit
(German/English)
B.Data - Web Client Minimum of 4 GB RAM

Energy accounting (costs and revenue accounting) Interface In addition to an interface to WinCC and S7
controllers, B.Data also offers the latest
Calculation and allocation/assignment of energy costs to plants interface standards such as OPC DA,
OPC HDA, OPC UA, MODBUS TCP, ODBC,
and/or customers/cost units in accordance with the costs-by- ASCII and XML.
cause principle. The bottom up (measurement) and top down
(allocation) procedures are supported here WinCC versions 1) SIMATIC WinCC V7.0 SP3, V7.2, V7.3 SE
SIMATIC WinCC RT Professional V13
Flexible modeling of the hierarchic accounting structures in
the Plant Explorer PCS 7 versions 2) SIMATIC PCS 7 V8
SIMATIC PCS 7 V8.0 SP1
Tariff allocation of quantities, flexible price assessment with SIMATIC PCS 7 V8.0 SP2
tariff and price time series 1)
If an acquisition computer is installed on a WinCC system, these require-
Transfer of costs/revenues to the ERP system ments must also be complied with.
(e.g. SAP R/3 CO) 2)
The SIMATIC B.Data system for connection to the PCS 7 must always be
installed on a separate PC.

Factors are based on:


Losses Accounting area Numbers of
(e.g. cost center) employees
Area data
Allocation formula
10% 90% 20% 80% etc.

Consumption area 1 ... n Consumption area 100% distribution


(e.g.: building 1) (e.g.: building 2) ensured

75% 25%
G_ST80_XX_00380

Counter 1 Counter 3

Counter 2

Energy planning
Generation of requirement forecasts based on production-
dependent factors (production planning) and basic load
profiles (typical days)

3/54 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC B.Data

Ordering data Article No. Article No.

SIMATIC B.Data V6.0 SP1 SIMATIC B.Data V6 expansions


Professional SIMATIC B.Data 3 Web Clients 6AV6372-2DF20-0AX0
Professional Start Package 6AV6372-2DF06-0AX0 SIMATIC B.Data 20 Web Clients 6AV6372-2DF20-0BX0
(including 50 tags) 1) SIMATIC B.Data 60 Web Clients 6AV6372-2DF20-0CX0
Tag Package 50 2) 6AV6372-2DF06-0CX0 SIMATIC B.Data Client 6AV6372-2DF30-0AX0
Tag Package 100 2) 6AV6372-2DF06-0DX0 SIMATIC B.Data 6AV6372-2DF40-0AX0
Tag Package 250 2) 6AV6372-2DF06-0EX0 Prognosis & Planning
Tag Package 500 2) 6AV6372-2DF06-0FX0 SIMATIC B.Data Acquisition 6AV6372-2DF50-0AX0
Tag Package 1 000 2) 6AV6372-2DF06-0GX0 Component
Tag Package 5 000 2) 6AV6372-2DF06-0HX0 SIMATIC B.Data Aquisition IPC V1.0 6BK1000-2BD00-0AC0
SUS up to 100 Tags 3) 6AV6372-2DF00-0DL0 (EnergyBox, turn-key solution
for max. additional 100 tags comprising IPC and acquisition
through tag packages component)
SUS up to 500 Tags 3) 6AV6372-2DF00-0FL0
for max. additional 500 tags SIMATIC B.Data upgrades
through tag packages V5.2/V5.3 to V6.0 SP1
SUS up to 5 000 Tags 3) 6AV6372-2DF00-0HL0 Upgrade from systems 6AV6372-2DF06-0DX4
for max. additional 5 000 tags
through tag packages
with up to 100 tags 6)
Upgrade from systems
with up to 500 tags 6)
6AV6372-2DF06-0FX4 3
SIMATIC B.Data V6.0 SP1 Upgrade from systems 6AV6372-2DF06-0HX4
Enterprise with up to 5 000 tags 6)
Enterprise 30 000 6AV6372-2DF66-0BX0 Upgrade from systems with more 6AV6372-2DF76-0XX4
with database 4) than 5 000 tags (Enterprise) 6)
Enterprise 30 000 6AV6372-2DF66-0AX0
without database 5)
Enterprise 60 000 6AV6372-2DF76-0BX0
with database 4)
Enterprise 60 000 6AV6372-2DF76-0AX0
without database 5)
SUS Enterprise 6AV6372-2DF70-0XL0
(more than 5 000 tags) 3)
for complete Enterprise line or
for Professional with more than
5 000 additional tags
PowerPack Enterprise, upgrade 6AV6372-2DF70-0XX0
from 30 000 to 60 000 tags

1) B.Data V6.0 SP1 Professional is delivered with an Oracle database 4) This version of SIMATIC B.Data V6.0 SP1 Enterprise is supplied with an
Standard Edition Embedded (max. 4 CPU sockets). For larger configu- Oracle Database Enterprise Edition Embedded. This is designed for larger
ration limits (starting with approx. 250 million stored measured values), you quantity structures (starting with approx. 250 million saved measured
need Oracle Database Enterprise Edition with the Partitioning Option. values).
2) The tag packages dynamically expand the number of tags. The total 5) This version of SIMATIC B.Data SP1 V6.0 Enterprise is supplied without a
number of tags is incremented by the value of the tag package in each database. It is recommended to use the Oracle Database Enterprise
case. Edition, which must be ordered separately from Oracle.
3) The SUS contract runs for 1 year. The contract is automatically extended 6) The upgrades are supplied without Oracle Database Enterprise Edition
by a further year unless canceled 3 months prior to expiration. Embedded.
For more detailed information, refer to:
http://www.siemens.com/bdata

More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-bdata

Siemens ST 80 / ST PC 2016 3/55


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC powerrate

Overview Design
SIMATIC powerrate comprises the following components:
Blocks for acquiring and conditioning energy data
Faceplates for displaying and editing energy data
Blocks for implementing load management (calculating the
trend, monitoring the limit, releasing/inhibiting loads),
batch-related consumption recording and for integrating
measuring instruments and switches
Additional blocks for example, for time synchronization, data
backup, data exchange with archives
Faceplates for displaying results and entering values
(e.g. for configuration, or manually measured values)
Excel-based reports for allocating energy data to cost
centers, for batch-related evaluation and for determining and
displaying the load duration curve
3 Exporting data to Excel

Function
Acquiring and conditioning energy data
SIMATIC powerrate, as an option for WinCC / PCS 7, ensures
transparency in energy consumption from the infeed to the load. Using ready-to-use function blocks, energy data can be
acquired by any PROFIBUS-capable devices. The data can
SIMATIC powerrate is used in all sectors in which WinCC or be input to the function blocks in the form of counter pulses,
PCS 7 are deployed and energy efficiency considerations play a count values or power values. Count values can also be entered
major role. Total integration into WinCC or PCS 7 means that manually.
there is no need for a special system environment. Predefined
modules and symbols give you the assurance of building on From this data, the function block calculates the power averages
tested product components, with interfaces that support and the work values for a predefined period. This calculated
customized expansion. data is subsequently saved in the WinCC archive. In addition, a
final value forecast is extrapolated for the power values for each
SIMATIC powerrate therefore provides a solution that you can period.
use to obtain an overview of the energy consumption of a plant
easily and cost-effectively through integration in an existing A sample function (heat calculation) that can be adapted to the
SIMATIC SCADA system. needs of the customer at any time by means of open interfaces
has been implemented for the purpose of visualizing customized
Benefits calculations.

Identification of energy-intensive equipment and processes to Data from manually read counters can be entered directly into
develop measures for improving energy efficiency. the system and used for further analysis. Absolute numerical val-
ues (entry of an absolute value instead of the difference from the
Comparison of consumption profiles for more efficient previous value) can also be recorded and used in further pro-
processes. cessing.
Optimization of the company according to energy parameters,
based on an evaluation of consumption and costs. Displaying energy data
Compliance with the contractually agreed power limits, thus The up-to-date, acquired energy data is displayed as power
preventing higher power supply costs or penalty payments. averages/work values for each time interval (total value for the
previous interval, current value of the current interval, extrapo-
Integration of the 7KM PAC3200/4200 measuring devices for
lated value for the end of the current interval). A load trend
a clear overview of selected measured values and alarms.
display enables analysis of archived energy data as well as its
Integration of switches with an overview of the switch status representation in tables.
and the switching possibilities.
Accurate assignment and comparison of the consumption
data of specific work processes or batches

3/56 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC powerrate

Function (continued)
Further processing of data Batch-related consumption recording
The archived data can be exported to Excel directly from WinCC A batch comprises all the units of a product that have
using the export functions. The exported energy data can also been produced in one production cycle, i.e. under identical
be included in further customized processing. WinCC tools can conditions. Batch-related consumption recording allows
be used to access the data from the WinCC archive. accurate recording of energy consumption for each batch.
Batch-related consumption recording is possible for five types
Reports of energy each with up to 10 loads. Appropriate reports can be
For this purpose, selected energy data is read from archives generated for analysis of the data (see also the batch report).
(Tag Logging archive, user archives) from the WinCC Runtime Integration of measuring devices 7KM PAC3200/PAC4200
database; using Microsoft Excel the following reports can then
be generated: If the 7KM PAC3200/PAC4200 measuring devices are inte-
Cost center report grated, selected measured values can be displayed and alarms
Here the consumption can be allocated to different cost (current, voltage, pulse frequency too high) can be generated
centers and the costs can be calculated on the basis of from the digital status information and displayed.
predefined tariffs. The results can be output by means of Integration of switches
2 reports in the form of tables or diagrams.
Load duration curve Switch integration via digital inputs/outputs (DI/DO) supports
display of the switch status (On, Off, tripped, unplugged).
3
An analysis is carried out on the basis of the archived power
averages to establish how often a certain power average has With the appropriate authorization, switching is also possible via
occurred in a given period. It can be quickly detected from the faceplate. Switching takes place in a 2-step operation
this characteristic curve whether temporary power peaks exist (switch command is issued, followed by a prompt for repeated
which can represent a possible starting point for cost savings confirmation; the switch command is not forwarded to the switch
by means of load management. until confirmation has been received).
Batch report WinCC WebNavigator support
This is used to allocate consumption to batches, whereby the
data can be presented in chronological order or in order of Makes the powerrate functionality available over the Web.
batch name.
Special functions
The generation of exports or reports can be initiated manually or
automatically time-controlled (daily, weekly or monthly). To avoid data loss in the event of a communication fault, the data
is stored temporarily in a circulating buffer on the S7.
Load management
Contractually agreed power limits (in the case of electricity,
normally the 15-minute average power value) must be observed,
otherwise significantly higher supply prices or even penalty
payments may become due to the energy supply company. The
load management feature of SIMATIC powerrate carries out
cyclic trend calculations in order to issue warnings/alarms if
violation of the limit is likely and to switch off loads in accordance
with the given configuration should this be required. If a limit is
exceeded despite this, the latest load management data is
archived to enable future evaluation or analysis.
To prevent unnecessary switching operations, numerous param-
eters are available for adapting the load management to the cur-
rent process conditions - and all this can be done conveniently
via the faceplate.
For loads that are distributed over different PLCs, SIMATIC
powerrate contains appropriate PLC-to-PLC communication
blocks which can be used to integrate these loads into the load
management system. Load management is scalable, according
to the maximum number of loads to be integrated or monitored,
for up to 10, 25, 50, 75 or 100 loads. Load management
can be performed for different media (e.g. electricity, gas)
simultaneously.

Siemens ST 80 / ST PC 2016 3/57


Siemens AG 2016

HMI Software
Software for energy management
SIMATIC powerrate

Technical specifications Ordering data Article No.

SIMATIC powerrate V4.0 SP3 SIMATIC powerrate V4.0 SP3 ES + 6AV6372-1DE04-0AX0


OS Runtime1)
Hardware requirements
Also includes:
SIMATIC powerrate can be PCS 7 License for WinCC/User Archive
used in the PCS 7 or WinCC STEP 7 and WinCC SCADA Block library PAC3200 for WinCC
SCADA environments. For Block library PAC3200,
installation, the respective 3WL/3VL for PCS 7
hardware requirements of the
following products apply SIMATIC powerrate V4.0 SP3 6AV6372-1DE04-0AX4
Upgrade
Released CPUs - SIMATIC S7-400 CPUs supported by PCS 7 Upgrade V3.x to V 4.0 SP3,
powerrate is released in the WinAC RTX 2010 SP1 and SP2 ES + OS-RT1)
PCS 7 environment for
SIMATIC powerrate V4.0 SP3 6AV6372-1DE04-0AX3
Released CPUs - SIMATIC S7-400 Update
powerrate is released in the S7-300 Update V4.0 (SP1 or SP2)
WinCC SCADA environment for: - SIMATIC S7 CPU 319-3 PN/DP V2.5 and to V4.0 SP3
higher
- SIMATIC S7 CPU 317-2 PN/DP V2.6 and SIMATIC powerrate V4.0 SP3 6AV6372-1DE04-0AX7

3
higher Trial License
- SIMATIC S7 CPU 315-2 PN/DP V3.1 and Limited 30-day
higher ES + OS Runtime license
SIMATIC ET 200S IM151-8 PN/DP CPU
V3.2 and higher 1) For operation on a WinCC/PCS 7 OS single-user workstation or server
Firmware version V3.x or later is and any number of automation systems. When using additional
recommended for S7-300 controllers. WinCC/PCS 7 OS single-user stations/servers, one license is required per
CPUs with firmware version V3.2 or higher WinCC/PCS 7 OS single-user station/server.
must be used for the implementation of
PROFIenergy I-device blocks
PR3_PE_IDEV and PRx_PE_RD. More information
WinAC RTX 2010 SP1 and SP2
Further information can be found on the Internet at:
Software requirements
http://www.siemens.com/simatic-powerrate
You can use SIMATIC PCS 7
powerrate in the PCS 7 or STEP 7 and WinCC SCADA Important information on the use of SIMATIC powerrate is
WinCC SCADA environments. available on the Internet at:
For installation, the respective
software requirements of the http://support.automation.siemens.com/WW/view/en/48204134
following products apply:
The library is released for the SIMATIC PCS 7 V8.1 SP1
following PCS 7 versions SIMATIC PCS 7 V8.1
SIMATIC PCS 7 V8.0 SP2
SIMATIC PCS 7 V7.1 SP4
The library is released for the SIMATIC WinCC V7.3 Second Edition
following WinCC version with SIMATIC WinCC V7.2 Update 1 or higher
the corresponding versions of (Update 2 is recommended)
STEP 7
For use with WinCC V7.3 or WinCC minimum installation
V7.2, the following installations - Basic Process Control
are required: - User archives for load management and
batch-oriented energy acquisition
WinCC add-on "AS-OS Engineering"
For the use of SIMATIC powerrate V4.0,
WinCC must execute in integrated mode
with STEP 7.
SIMATIC NET
STEP 7
powerrate Reports has been Microsoft Excel 2003
released for the following Microsoft Excel 2007
versions Microsoft Excel 2010
Microsoft Excel 2013

3/58 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
Introduction, SIMATIC WinCC flexible ES

Overview SIMATIC WinCC flexible HMI system Overview SIMATIC WinCC flexible ES
SIMATIC WinCC flexible ES engineering software
Family of configuration systems with WinCC flexible
Micro/Compact/Standard/Advanced for SIMATIC operator
panels, the HMI part of SIMATIC C7 as well as for the
PC-based visualization software WinCC flexible Runtime
Runs under Windows XP Professional / Windows 7
Professional, Ultimate, Enterprise
Can be expanded by the option
"WinCC flexible/ChangeControl" for version management and
change logging
SIMATIC WinCC flexible Runtime visualization software
Modular PC-based HMI solution for single-user systems
directly at the machine (further development of
ProTool/Pro RT)
Runs under Windows XP Professional / Windows 7
Professional, Ultimate, Enterprise
3
Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program) Uniform family of engineering tools for configuration
Can be integrated into automation solutions based on SIMATIC HMI Operator Panels, the operator control part of
TCP/IP networks SIMATIC C7 units, SIMOTION/SINUMERIK Panel PCs as well
Expanded service concepts with remote operation, as the PC-based visualization software WinCC flexible
diagnostics and administration over the intranet and Internet Runtime.
in combination with email communication Runs under Windows XP Professional / Windows 7
Professional, Ultimate, Enterprise
Current version:
- SIMATIC WinCC flexible 2008 SP3 Micro
- SIMATIC WinCC flexible 2008 SP3 Compact
- SIMATIC WinCC flexible 2008 SP3 Standard
- SIMATIC WinCC flexible 2008 SP3 Advanced

Siemens ST 80 / ST PC 2016 3/59


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
Introduction, SIMATIC WinCC flexible ES

Application
SIMATIC WinCC flexible Micro/Compact/Standard/Advanced WinCC flexible Standard
are engineering tools for configuring SIMATIC HMI devices, the
operating component of SIMATIC C7 devices, the SIMOTION/ In addition to the target systems that are configured using
SINUMERIK Panel PCs as well as the PC-based visualization WinCC flexible Compact:
system WinCC flexible Runtime. Mobile Panels: Mobile Panel 277
Depending on the selected product, various target systems can 270 series Panels: TP 270, TP 277, OP 270, OP 277
be configured: 270 series Multi Panels: MP 270B, MP 277
WinCC flexible Micro 370 series Multi Panels: MP 370, MP 377
Micro Panels: OP 73micro, TP 170micro, TP 177micro C7 devices: C7-636 (Touch/Key)

WinCC flexible Compact WinCC flexible Advanced

In addition to the target systems that are configured using In addition to the target systems that are configured using
WinCC flexible Micro: WinCC flexible Standard:
Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic, Standard PC

3 TP1500 Basic
Mobile Panels: Mobile Panel 170, Mobile Panel 177
SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77,
Panel PC 477/477B, Panel PC 577/577B, Panel PC 670,
Panel PC 677/677B, Panel PC 870, Panel PC 877
70 series Panels: OP 73, OP 77A, OP 77B
SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR,
170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B, PCR-Touch
OP 170B, OP 177B
SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012,
170 series Multi Panels: MP 177 OP015, TP015, OP015A
C7 devices: C7-635 (Touch/Key)
For configuring panels released after the start of delivery of
WinCC flexible 2008, an HSP (Hardware Support Package) is
required that can be downloaded free of charge via the following
link: http://www.siemens.com/wincc-flexible-hsp

3/60 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
Introduction, SIMATIC WinCC flexible ES

Technical specifications Ordering data Article No.

System requirements WinCC flexible Engineering WinCC flexible 2008 Micro


(minimum requirements) Software incl. SP3
Operating system Windows XP Professional SP3 (32-bit), Software and documentation 6AV6610-0AA01-3CA8
Windows 7 Professional, Ultimate, on DVD, single license,
Enterprise (32-bit and 64-bit) without license key
as download 4), 6AV6610-0AA01-3CH8
Additionally for software download, single license,
SIMATIC WinCC flexible Micro: without license key download,
Windows XP Home SP3 e-mail address required for the
Processor Pentium 4 (or comparable) processor delivery
running at 1.6 GHz or faster WinCC flexible 2008 Compact
Resolution 1024 x 768 or higher incl. SP3
Software and documentation 6AV6611-0AA51-3CA5
Main memory (RAM) 1 GB, on DVD, floating license,
512 MB for WinCC flexible Micro license key on USB stick
Hard disk (free memory space) 1) 2 GB 2) as download 4), 6AV6611-0AA51-3CH5
1.2 GB for WinCC flexible Micro 3) software and license key

3
download, floating license,
DVD drive for software installation e-mail address required for the
1) delivery
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk; WinCC flexible 2008 Standard
e.g. for the swap file. The following formula has proven itself in the past: incl. SP3
The size of the swap file = 3 x the size of available RAM. Software and documentation 6AV6612-0AA51-3CA5
For further information, refer to your Windows documentation on DVD, floating license,
2) When installing one language. An additional 200 MB are required for each license key on USB stick
further language. In the case of different partitions for system and configu- as download 4), 6AV6612-0AA51-3CH5
ration: System partition approx. 700 MB, project partition approx. 1.3 GB. software and license key
3) When installing one language. An additional 80 MB are required for each download, floating license,
e-mail address required for the
further language. In the case of different partitions for system and configu-
delivery
ration: System partition approx. 600 MB, project partition approx. 600 MB.

4) Current information and availability regarding the new type of delivery can
be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC 2016 3/61


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
Introduction, SIMATIC WinCC flexible ES

Ordering data Article No. Article No.


WinCC flexible 2008 Advanced Upgrades
incl. SP3
SIMATIC WinCC flexible
Software and documentation 6AV6613-0AA51-3CA5 2004/2005/2007
on DVD, floating license, to SIMATIC WinCC flexible
license key on USB stick 2008 incl. SP3
as download 4), 6AV6613-0AA51-3CH5 Upgrade to WinCC flexible 2008 6AV6610-0AA01-3CE8
software and license key Micro 3)
download, floating license,
e-mail address required for the Upgrade to WinCC flexible 2008 6AV6611-0AA51-3CE5
delivery Compact, incl. ChangeControl
option 1)
WinCC flexible /ChangeControl Upgrade to WinCC flexible 2008 6AV6612-0AA51-3CE5
for WinCC flexible 2008 Standard, incl. ChangeControl
Compact/Standard/Advanced 1) 2) option 1)
Floating license, option, 6AV6613-6AA01-3AB5 Upgrade to WinCC flexible 2008 6AV6613-0AA51-3CE5
license key only Advanced, incl. ChangeControl
as download 4), 6AV6613-6AA01-3AH5 option 1)
only license key download,
floating license, as download 4)

3 e-mail address required for the


delivery
E-mail address required for the
delivery
Powerpacks Upgrade to WinCC flexible 2008 6AV6610-0AA01-3CK8
Micro 3)
SIMATIC WinCC flexible Upgrade to WinCC flexible 2008 6AV6611-0AA51-3CK5
Power Packs Compact, incl. ChangeControl
Floating license, option 1)
license key only on USB stick Upgrade to WinCC flexible 2008 6AV6612-0AA51-3CK5
WinCC flexible 2008 Standard to 6AV6613-2CD01-3AD5 Standard, incl. ChangeControl
2008 Advanced option 1)
WinCC flexible 2008 Compact to 6AV6613-2BD01-3AD5 Upgrade to WinCC flexible 2008 6AV6613-0AA51-3CK5
2008 Advanced Advanced, incl. ChangeControl
WinCC flexible 2008 Compact to 6AV6612-2BC01-3AD5 option 1)
2008 Standard SIMATIC WinCC flexible ASIA
as download 4), 2004/2005/2007
floating license, to SIMATIC WinCC flexible ASIA
license key download only, 2008 incl. SP3
e-mail address required for the Upgrade to WinCC flexible 2008 6AV6612-0AA11-3CE5
delivery ASIA Standard,
WinCC flexible 2008 Standard to 6AV6613-2CD01-3AJ5 incl. ChangeControl option 1)
2008 Advanced Upgrade to WinCC flexible 2008 6AV6613-0AA11-3CE5
WinCC flexible 2008 Compact to 6AV6613-2BD01-3AJ5 ASIA Advanced,
2008 Advanced incl. ChangeControl option 1)
WinCC flexible 2008 Compact to 6AV6612-2BC01-3AJ5
2008 Standard Versions for
China/Taiwan/Korea/Japan
Updates
WinCC flexible 2008 ASIA 6AV6612-0AA11-3CA5
WinCC flexible 2008 Micro 6AV6610-0AA51-3CU8 Standard incl. SP3
Update 2008, 2008 SP1, 2008 SP2 Floating license, license key on
-> 2008 SP3 USB stick, software and
WinCC flexible 2008 6AV6613-0AA51-3CU8 documentation on DVD,
Compact/Standard/Advanced WinCC flexible 2008 ASIA 6AV6613-0AA11-3CA5
Update 2008, 2008 SP1, 2008 SP2 Advanced incl. SP3
-> 2008 SP3 Floating license, license key on
USB stick, software and
documentation on DVD,
1)
A separate license for WinCC flexible/ChangeControl must be purchased
for each engineering station
2)
The ChangeControl option has not been released for integrated operation
with STEP 7
3)
Original delivery note or Certificate of License (CoL) from previous WinCC
flexible Micro is required
4)
Current information and availability regarding the new type of delivery can
be found at: http://www.siemens.com/tia-online-software-delivery

More information
Additional information is available in the Internet under: Note
http://www.siemens.com/wincc-flexible Do you require a specific modification or extension to the
products described here? You will find information about the
Open Platform Program for the creation of user-specific
functions and controls for WinCC flexible under "Customized
Products".

3/62 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Overview Application
SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PCs 477/477B/477C
- Panel PCs 577/577B/577C
- Panel PCs 670/677/677B/677C
- Panel PCs 870/877
SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
Standard PCs with resolutions (W x H in pixels) of:
3
- 4:3 format: 640 x 480, 800 x 600, 1 024 x 768, 1 280 x 1 024,
1 600 x 1 200
- Widescreen format: 800 x 480, 1 280 x 800, 1 366 x 768,
1 440 x 900, 1 680 x 1 050, 1 920 x 1 080, 1 920 x 1 200,
PC-based visualization software for single-user systems directly 1 980 x 1 080
at the machine.
Runs under Windows XP Professional and Windows 7
Professional, Ultimate, Enterprise
Design
Current version: SIMATIC WinCC flexible 2008 SP3 Runtime SIMATIC WinCC flexible Runtime is available as a software
package with 128, 512, 2048 or 4096 PowerTags. The term
SIMATIC WinCC flexible Runtime is configured with the PowerTags is used exclusively to identify process variables and
SIMATIC WinCC flexible Advanced configuration software. range pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and it
can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.

Siemens ST 80 / ST PC 2016 3/63


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Function Integration
System requirements WinCC flexible Runtime SIMATIC WinCC flexible Runtime supports linking to:
Operating system Windows XP Professional SP3 (32-bit) Protocol PC interfaces
Windows XP Embedded 1)
Windows 7 Professional / Ultimate / SIMATIC S5 via AS511 (TTY)
Enterprise (32-bit and 64-bit)
S5-90U COM1/COM2 13)
Processor4)
S5-90U
Minimum Windows XP: 300 MHz
Windows 7: 1 GHz S5-100U (CPU 100, 102, 103)
Recommended Windows XP: Pentium III, 500 MHz S5-115U
Windows 7: 1 GHz (CPU 941, 942, 943, 944, 945)
Graphics S5-135U (CPU 928A, 928B)
Minimum SVGA
S5-155U (CPU 946/947, 948)
Resolution 640 x 480 to 1600 x 1200 or
800 x 480 to 1980 x 1080 SIMATIC S5 via PROFIBUS DP 1)
RAM 2) S5-95U/L2-DP master CP 5512 2)
CP 5611 A2 2)
3
Minimum Windows XP: 128 MB
S5-115U
Windows 7: 1 GB
(CPU 941, 942, 943, 944, 945)
Recommended Windows XP: 512 MB
Windows 7: 1 GB S5-135U (CPU 928A, 928B)
Hard disk (free memory space) 3)
250 MB S5-155U (CPU 946/947, 948)
1) Only for enabled platforms (e.g. Panel PC 477). You can get information SIMATIC S7 via PPI
from your Siemens contact. S7-200 CP 5611 A2 2)
2) RAM requirements are determined primarily by the size of the graphics CP 5612
used. CP 5621 1)
3) Without taking archives into account. CP 5622
In addition to the space needed by WinCC flexible, Windows also requires CP 5613 A3
space on the hard disk; e.g., for the swap file. The following formula has CP 5614 A3
proven itself in the past: The size of the swap file = 3 x the size of the RAM. CP 5623
For further information, refer to your Windows documentation CP 5624
4) CP 5711
More powerful systems (Pentium 4 and higher) may be required in order to PC/PPI adapter 3)
use options
SIMATIC S7 via MPI
S7-200 (except CPU 212) 4) CP 5611 A2 2)
CP 5612
S7-300 CP 5621 1)
S7-400 CP 5622
CP 5613 A3
WinAC Basis (V3.0 and higher) CP 5614 A3
CP 5623
WinAC RTX
CP 5624
CP 5711
PC adapter USB A2 6)
Teleservice V6.1
1) WinCC flexible Runtime is passive (DP slave); the function block required
for the link is included in the scope of delivery of WinCC flexible
2) For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface
3) Only point-to-point to S7-200; no configuration download, operating
systems: Windows XP; Article number: 6ES7901-3CB30-0AX0
4) Constraint with regard to baud rate for S7-200; see Catalog ST 70
6) Only point-to-point to S7-300/-400; no configuration download, operating
systems: Windows XP or higher; article number: 6GK1571-0BA00-0AA0
(USB)

3/64 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Integration (continued)
Protocol PC interfaces Protocol PC interfaces
SIMATIC S7 via PROFIBUS DP 5) SIMATIC S7 via integrated interface
S7-215 4) CP 5611 A2 2) WinAC Basis (V2.0 and higher) Internal system interface
CP 5612
S7-300 CPUs with integral CP 5621 1) WinAC RTX
PROFIBUS-SS CP 5622 SIMATIC 505 NITP
S7-300 with CP 342-5 CP 5613 A3
CP 5614 A3 SIMATIC 500/505 RS 232/RS 422 COM1/COM2
S7-400 CPUs with integral CP 5623
PROFIBUS-SS SIMATIC 505 via PROFIBUS DP
CP 5624
S7-400 with CP 443-5 or IM 467
CP 5711 SIMATIC 545/555 with CP 5434 CP 5612 2)
CP 5622 2)
WinAC Basis (V3.0 and higher)
SIMOTION 8)
WinAC RTX
SINUMERIK 9)
SIMATIC S7 via Ethernet (TCP/IP)
Third-party controllers
S7-200 with CP 243-1 CP 1612 A2 7)

3
CP 1613 A2 Allen Bradley (DF1/DH485) COM1/COM2
S7-300 CPUs with integral Ethernet
interface Allen Bradley (Ethernet) CP 1612 A2 7)

S7-300 with CP 343-1 GE Fanuc (SNP/SNPX) COM1/COM2

S7-400 CPUs with integral Ethernet LG GLOFA GM COM1/COM2


interface Mitsubishi (FX/MP4) COM1/COM2
S7-400 with CP 443-1 Modicon (Modbus) COM1/COM2
WinAC Basis (V3.0 and higher) Modicon (Modbus TCP/IP) CP 1612 A2 7)
WinAC RTX OMRON (Link/Multilink) COM1/COM2
OPC 10) 12)
Data Access V2.05a (client + server) CP 1612 A2 7)
Data Access XML V1.00 (client)
HTTP communication for data CP 1612 A2 7)
exchange between SIMATIC HMI
(client + server) 11) 12)

1)
WinCC flexible Runtime is passive (DP slave); the function block required Application note
for the link is included in the scope of delivery of WinCC flexible
2)
For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface In parallel with each and every PLC link, WinCC flexible Runtime
3) supports the use of the OPC Client channel; this enables,
Only point-to-point to S7-200; no configuration download, operating
systems: Windows XP; Article number: 6ES7901-3CB30-0AX0 for example, connection to an SNMP OPC Server for the purpose
4) of visualizing the data stored there. The SNMP OPC Server
Constraint with regard to baud rate for S7-200; see Catalog ST 70
5)
provides a means of monitoring network components of any type
WinCC flexible RT is active; communication with S7 functions (e.g. switches) which support the SNMP protocol. For further
6)
Only point-to-point to S7-300/-400; no configuration download, operating information, see Catalog IK PI.
systems: Windows XP or higher; article number: 6GK1571-0BA00-0AA0
(USB) Note:
7)
For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet For further information, see "Operator Control and Monitoring
interface Devices/System interfaces"
8)
For further information, see Catalog PM 10
9)
"SINUMERIK HMI copy license OA" option required; for further information,
see Catalog NC 60
10)
OPC Client is included in scope of delivery, the "WinCC flexible/OPC
Server for WinCC flexible Runtime" license is required for the OPC Server
option
11)
"WinCC flexible/Sm@rtAccess for WinCC flexible Runtime" license required
12)
OPC and HTTP communication are additive, i.e. can be used in
conjunction with the PLC links listed above
13)
Via PC cable with integrated level converter RS 232/TTY;
Article number: 6ES5734-1BD20
For information about SIMATIC Panels that support OPC/http
communication, see the overview under "System interfaces".

Siemens ST 80 / ST PC 2016 3/65


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Technical specifications Ordering data Article No.

Type SIMATIC WinCC flexible Runtime SIMATIC WinCC flexible 2008


Runtime
The specifications are maximum
values for PC systems; software and
documentation on DVD,
Displays 500 including software of the options for
Fields per screen 400 PC systems 1) ;
Variables per screen 400 Single license,
Static text 30,000 license key on USB stick for:
Graphics objects 2,000 128 PowerTags (RT 128) 6AV6613-1BA51-3CA0
Complex objects per display 40 512 PowerTags (RT 512) 6AV6613-1DA51-3CA0
(e.g. bars) 2 048 PowerTags (RT 2 048) 6AV6613-1FA51-3CA0
Trends 800 4 096 PowerTags (RT 4 096) 6AV6613-1GA51-3CA0
Graphics lists 1) 500 as download 2)
Text lists 1) 500 Single license, software and
Number of entries in symbol tables 3,500 license key download.
E-mail address required for the
Variables 4,096 3) delivery.
3 Messages bit-triggered / analog
Message text
4,000 / 500
80
128 PowerTags
512 PowerTags
6AV6613-1BA51-3CH0
6AV6613-1DA51-3CH0
(number of characters) 2 048 PowerTags 6AV6613-1FA51-3CH0
Number of process values 8 4 096 PowerTags 6AV6613-1GA51-3CH0
per message
Powerpacks
Size of message buffer 1,024
Pending message events 500 SIMATIC WinCC flexible 2008
Runtime
Archives 4) 100
Single license, license key only on
Archivable data Process data, messages USB stick for PowerTags from
Max. number of entries per archive 500,000 128 to 512 PowerTags 6AV6613-4BD01-3AD0
(incl. all archive segments)
128 to 2 048 PowerTags 6AV6613-4BF01-3AD0
Archive types Short-term archive, sequence archive
128 to 4 096 PowerTags 6AV6613-4BG01-3AD0
(max. 400 per archive)
512 to 2 048 PowerTags 6AV6613-4DF01-3AD0
Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base), 512 to 4 096 PowerTags 6AV6613-4DG01-3AD0
interface to MS SQL database 2 048 to 4 096 PowerTags 6AV6613-4FG01-3AD0
Recipes4) 1,000 as download 2)
Elements per recipe 2,000 3) Single license,
license key download only.
Data records per recipe 5,000 2)
E-mail address required for the
Password protection delivery.
User rights 32 128 to 512 PowerTags 6AV6613-4BD01-3AJ0
Number of user groups 50 128 to 2 048 PowerTags 6AV6613-4BF01-3AJ0
128 to 4 096 PowerTags 6AV6613-4BG01-3AJ0
Visual Basic scripts 200
512 to 2 048 PowerTags 6AV6613-4DF01-3AJ0
Online languages, max. 16 512 to 4 096 PowerTags 6AV6613-4DG01-3AJ0
Communication 2 048 to 4 096 PowerTags 6AV6613-4FG01-3AJ0
SIMATIC S7 MPI interface/ Updates
PROFIBUS DP interface
SIMATIC WinCC flexible 2008 6AV6613-1XA51-3CU8
Number of connectable stations, Depending on the scope of the Runtime Update 2008, 2008 SP1,
max. configuration (communication) from 2008 SP2 -> 2008 SP3
the point of view of WinCC flexible
Runtime, as many as 8 connections
are possible
SIMATIC S7 PPI interface
Number of connectable stations, 1 from viewpoint of WinCC flexible
max. Runtime
SIMATIC S5
PROFIBUS DP interface
Number of connectable stations, 1 from viewpoint of WinCC flexible
max. Runtime
Multi-protocol operation Yes, OPC Client or SIMATIC HMI
HTTP protocol are additive, i.e. can
be used in conjunction with other PLC
links
1) 1)
Together only 500 text and graphics lists Runtime licenses for WinCC flexible Runtime options must be purchased
2) Dependent on memory medium used separately for each target system.
2)
3) Current information and availability regarding the new delivery package
Dependent on number of licensed PowerTags can be found at: http://www.siemens.com/tia-online-software-delivery
4) Option for SIMATIC WinCC flexible Runtime. For further information, refer to
"WinCC flexible options".

3/66 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Ordering data Article No. Article No.


Upgrades Communication via
Industrial Ethernet
SIMATIC WinCC flexible
2004/2005/2007 Runtime CP 1613 A2 6GK1161-3AA01
to SIMATIC WinCC flexible PCI card (32-bit) for connecting a
2008 Runtime PG/PC to Industrial Ethernet
Upgrade to (communications software must be
SIMATIC WinCC flexible Runtime ordered separately)
2008 PowerTags SIMATIC NET HARDNET-IE S7
including runtime options for: V12
WinCC flexible /Archives; Software for S7 communication and
WinCC flexible /Recipes; open communication; OPC,
WinCC flexible /Audit; PG/OP communication, configuring
WinCC flexible /Sm@rtAccess; software; up to 120 connections;
WinCC flexible /OPC-Server; Single License for 1 installation of
WinCC flexible /ProAgent runtime software, software and
Software and documentation 6AV6613-1XA51-3CE0 electronic manual on DVD
on DVD, single license, Single license for 1 installation 6GK1716-1CB12-0AA0
license key on USB stick
as download 2),
software and license key
6AV6613-1XA51-3CK0
Software Update Service for one
year, with automatic extension;
requirement: Current software
6GK1716-1CB00-3AL0
3
download, single license, version
e-mail address required for the
delivery Upgrade S7-1613 from V6.4 6GK1716-1CB00-3AE0
to S7-1613 V8.0 SP1
Upgrade of the Upgrade S7-1613 from V6.0, V6.1, 6GK1716-1CB00-3AE1
SIMATIC WinCC flexible Panel V6.2 or V6.3 to S7-1613 V8.0 SP1
options:
WinCC flexible /Audit
for SIMATIC Panel;
WinCC flexible /Sm@rtAccess
for SIMATIC Panel;
WinCC flexible /Sm@rtService
for SIMATIC Panel;
WinCC flexible /OPC-Server
for SIMATIC Multi Panel;
WinCC flexible /ProAgent
for SIMATIC Multi Panel
only license key on USB stick, 6AV6618-7XX01-3AF0
single license
as download 2), 6AV6618-7XX01-3AK0
only license key download,
single license,
e-mail address required for the
delivery
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC 2016 3/67


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

Ordering data Article No. Article No.


Communication via PROFIBUS CP 5612 6GK1561-2AA00
CP 5613 A3 6GK1561-3AA02 PCI card (32-bit) for connecting a
PG/PC to PROFIBUS
PCI card (32-bit) for connecting a (communications software included
PC to PROFIBUS in WinCC flexible basic package)
(communications software must be
ordered separately) CP 5622 6GK1562-2AA00
CP 5614 A3 6GK1561-4AA02 PCI Express X1 card (32-bit) for
connection of PG/PC to
PCI card (32-bit) for connecting a PROFIBUS or MPI
PC to PROFIBUS (communications software included
(communications software must be in WinCC flexible basic package)
ordered separately)
CP 5711 6GK1571-1AA00
SIMATIC NET PB S7-5613 V8.0
SP1 USB adapter (USB V2.0) for
connecting a PG/notebook to
Software for S7 communication, PROFIBUS or MPI
incl. PG and FDL protocol, (communications software included
OPC server and NCM PC; in WinCC Basic package)
Runtime software, software and
3 electronic manual on USB flash
drive, license key on diskette,
SIMATIC S7, MPI cable
For linking SIMATIC S7 and
6ES7901-0BF00-0AA0

Class A, for 32-bit Windows 7 PG via MPI


Professional/Ultimate
for up to 4 CP 5613 A2, CP5614 A2, PC/PPI adapter 6ES7901-3CB30-0XA0
CP 5603 / CP 5623 / CP 5624; RS 232, 9-pin; male with RS 232/PPI
Single license for 1 installation 6GK1713-5CB80-3AA0 converter, max. 19.2 kbps
Software Update Service for one 6GK1713-5CB00-3AL0
year, with automatic extension;
requirement: Current software
version
Upgrade S7-5613 from V6.4 6GK1713-5CB00-3AE0
to S7-5613 V8.0 SP1
Upgrade S7-5613 from V6.0, V6.1, 6GK1713-5CB00-3AE1
V6.2 or V6.3 to S7-5613 V8.0 SP1

More information
Additional information is available in the Internet under: Note
http://www.siemens.com/wincc-flexible Do you need a specific modification or option for the products
described here? You will find information about the Open
Platform Program for the creation of user-specific functions and
controls for WinCC flexible under "Customized Products".

3/68 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options

Overview
Option for SIMATIC WinCC flexible Engineering SIMATIC Logon for WinCC flexible
SIMATIC WinCC flexible /ChangeControl Option for connecting PCs with SIMATIC WinCC flexible Runtime
and SIMATIC Panels to central user administration.
WinCC flexible/ChangeControl enables consistent backup of
configuration data. The history of changes can be verified down SIMATIC WinCC flexible /Sm@rtAccess
to the last detail for applications requiring interruption-free proof Flexible solution for access to HMI systems and process data
for the complete life cycle of a product. from any location
Options for SIMATIC Panels/Multi Panels and Communication between different SIMATIC HMI systems
SIMATIC WinCC flexible Runtime
SIMATIC WinCC flexible /Sm@rtService
SIMATIC WinCC flexible /Archives Remote maintenance and servicing of machines and plant via
Archiving of alarms and process values Internet/intranet
SIMATIC WinCC flexible /Recipes Flexible solution for remote access to machines and plant

Generation and management of data records for machine or SIMATIC WinCC flexible /OPC Server
production data
SIMATIC WinCC flexible /Audit
Incorporation of automation components from different
vendors into a single automation concept 3
Communication for data exchange between HMI systems
Recording of operator actions in an Audit Trail and/or higher-level control system
Audit supports users in meeting special quality requirements, SIMATIC WinCC flexible /ProAgent
e.g.
- Production plant requiring validation according to Precise and rapid process fault diagnostics in plant and
21 CFR Part 11 (Food Drug Administration law) machines for SIMATIC S7 and SIMATIC HMI
- In respect of traceability according to EU 175/2002 Standardized diagnostics concept for various SIMATIC
(EU directive) components
No further configuration overhead for diagnostics functionality

Siemens ST 80 / ST PC 2016 3/69


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl

Overview Ordering data Article No.


Options for the versioning of configuration data and for tracing WinCC flexible /ChangeControl
configuration changes (e.g. as verification in regulated for WinCC flexible 2008
sectors) Compact/Standard/Advanced 1)
For the engineering tool SIMATIC WinCC flexible Floating license, 6AV6613-6AA01-3AB5
Compact/Standard/Advanced license key only on USB stick
One license is required for each configuration computer as download 2) 6AV6613-6AA01-3AH5
Floating license,

Benefits only license key download


E-mail address required for the
delivery
Consistent backup of configuration data
- Delivered versions, approved reference states or 1)
The ChangeControl option has not been released for integrated operation
development stages are managed in a database. with STEP 7.
- Changes to project data can be integrated without problem 2)
Current information and availability regarding the new delivery package
into the version management using new versions. A rollback can be found at: http://www.siemens.com/tia-online-software-delivery
is possible at any time.
More information
3
Tracing of configuration changes
- The history of changes can be verified down to the last detail
for applications requiring interruption-free proof for the Note
complete life cycle of a product. Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.

3/70 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /Archives

Overview Ordering data Article No.


Option for SIMATIC WinCC flexible Runtime for archiving WinCC flexible /Archives for
process values and messages WinCC flexible 2008 Runtime 1)
Archiving of process values and messages supports the Single license, 6AV6618-7ED01-3AB0
acquisition and processing of process data from an industrial license key only on USB stick
plant or machine. Evaluation of the archived process data
as download 2) 6AV6618-7ED01-3AH0
provides information about the operating states of the plant or Single license,
machine license key download only
One license is required per operator station (no license is E-mail address required for the
delivery
required for SIMATIC Panels/Multi Panels)
WinCC flexible /Archives+Recipes
for WinCC flexible 2008 Runtime 1)
Technical specifications Single license per option, 6AV6618-7GD01-3AB0
license key only on USB stick
Type WinCC flexible /Archives
as download 2) 6AV6618-7GD01-3AH0
The specifications are maximum Single license for each option,
values license key download only
Execution platform
Archives
SIMATIC WinCC flexible Runtime
100
E-mail address required for the
delivery 3
1) One license is required for each operator station. A license is not required
Archivable data Process values, messages
Cyclical trigger for archiving process 1s for the engineering system for configuring the runtime option.
values (variables) 2) Current information and availability regarding the new delivery package
Max. number of entries per archive 500,000 1) can be found at: http://www.siemens.com/tia-online-software-delivery
(incl. sequence archive)
Archive types Circulating archive More information
Sequence archive
(max. 400 per archive) Note
Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base) and
Do you need a specific modification or option for the products
interface to Microsoft SQL database described here? Then look up "Customized products", where
(database not included in scope of you will find information about the Open Platform Program for the
delivery) creation of user-specific functions and controls for
1) WinCC flexible.
Dependent on memory medium used

Siemens ST 80 / ST PC 2016 3/71


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /Recipes

Overview Ordering data Article No.


Option for SIMATIC WinCC flexible Runtime for managing data WinCC flexible /Recipes for
records in recipes that contain related machine or production WinCC flexible 2008 Runtime 1)
data
Single license, 6AV6618-7FD01-3AB0
The data in a data set can be transferred, for example, from license key only on USB stick
the control unit to the PLC to switch production to a different 6AV6618-7FD01-3AH0
as download 2)
product variant Single license,
One license is required per operator station (no license is license key download only
required for SIMATIC Panels/Multi Panels) E-mail address required for the
delivery

Technical specifications WinCC flexible /Archives+Recipes


for WinCC flexible 2008 Runtime 1)

Type WinCC flexible /Recipes Single license per option, 6AV6618-7GD01-3AB0


license key only on USB stick
The specifications are maximum
values as download 2) 6AV6618-7GD01-3AH0
Single license for each option,
Execution platform SIMATIC WinCC flexible Runtime license key download only
3 Recipes
Entries per recipe
1000
2000 1)
E-mail address required for the
delivery
1)
Data records per recipe 5000 2) One license is required for each operator station. A license is not required
User data length in bytes per data 8000 KB 2) for the engineering system for configuring the Runtime option.
record 2) Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
1)
Dependent on number of licensed PowerTags

More information
2)
Dependent on memory medium used

Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.

3/72 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /Audit

Overview Ordering data Article No.


Option for SIMATIC WinCC flexible Runtime as well as WinCC flexible /Audit for
SIMATIC Panels for recording operations in an audit trail, and SIMATIC Panels 1)
electronic signature
Single license, 6AV6618-7HB01-3AB0
The audit trail features a safety mechanism that indicates license key only on USB stick
subsequent manipulation.
as download 2) 6AV6618-7HB01-3AH0
An easy-to-use configuration option included as standard in Single license,
WinCC flexible enables you to set: license key download only
- The operator actions to be recorded in the audit trail during E-mail address required for the
delivery
runtime
- The important operator actions requiring electronic WinCC flexible /Audit for
signature/comments during runtime WinCC flexible Runtime 2008 1)

The audit option combined with the WinCC flexible ES Single license, license key only on 6AV6618-7HD01-3AB0
USB stick
ChangeControl option supports the user with plant validation
as download 2) 6AV6618-7HD01-3AH0
Available for the following SIMATIC HMI systems: Single license,
TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377, license key download only
WinCC flexible Runtime
A license for WinCC flexible /Archives and
E-mail address required for the
delivery 3
WinCC flexible /Audit is required for every operator control unit 1) One license is required for each operator console. A license is not required
(panel or PC) for the engineering system for configuring the runtime option.
2) Current information and availability regarding the new delivery package
Technical specifications can be found at: http://www.siemens.com/tia-online-software-delivery

WinCC flexible /Audit More information


Archive for Audit Trail use on the Plug-in flash memory card on the Note
Panel panel
In the higher-level PC (memory Do you need a specific modification or option for the products
medium) connected to the panel via described here? Then look up "Customized products", where
Ethernet you will find information about the Open Platform Program for the
Archive for Audit Trail use of On the PC (storage medium) creation of user-specific functions and controls for
WinCC flexible Runtime WinCC flexible.
Execution platform
SIMATIC Panels Mobile Panel 277, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels MP 270B, MP 277, MP 370, MP 377
PCs SIMATIC WinCC flexible Runtime

Siemens ST 80 / ST PC 2016 3/73


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible

Overview Technical specifications


Option for connecting PCs with SIMATIC WinCC flexible SIMATIC Logon for WinCC flexible
Runtime and SIMATIC Panels to SIMATIC Logon central user
administration. Execution platform
Creates user administration on a central computer to which SIMATIC Panels Mobile Panel 177 PN;
one or more WinCC flexible stations can be connected over Mobile Panel 277,
TP/OP 177B PN/DP, TP/OP 277
Ethernet.
SIMATIC Multi Panels MP 177, MP 277, MP 377
SIMATIC Logon for WinCC flexible supports the user in
combination with the /Audit and /ChangeControl options in PCs WinCC flexible Runtime
meeting requirements in accordance with FDA 21 CFR Part 11
and EU178.
Ordering data Article No.
Design SIMATIC Logon V1.5 6ES7658-7BX51-0YA0
SIMATIC Logon and SIMATIC Logon Remote Access are Basic license;
for panels or WinCC flexible
installed on a central station. Runtime stations,

3 The following WinCC flexible stations are connected to the the corresponding number of
additional SIMATIC Logon Remote
central station via Ethernet network: Access licenses is required.
PCs with WinCC flexible Runtime SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0
SIMATIC Panels from the 177 series or higher (panels with SIMATIC Logon Remote Access 6ES7658-7BA00-2YB0
Ethernet interface) for WinCC flexible (3 clients)
Remote access for
Licensing 3 WinCC flexible 2008 clients;
The following licenses are required: single license for
3 remote access clients;
SIMATIC Logon basic license type of delivery:
CD, license key disk, Certificate of
SIMATIC Logon Remote Access license (3-pack or 10-pack License, Terms and Conditions
license); more than one SIMATIC Logon Remote Access The number of licensed clients is
license can be installed. determined based on the amount of
installed SIMATIC logon remote
The number of connectable stations depends on the SIMATIC access licenses.
Logon Remote Access licenses used. This number is the total of
SIMATIC Logon Remote Access 6ES7658-7BB00-2YB0
the connections provided by the individual licenses. As an for WinCC flexible (10 clients)
example: Two installed licenses for 10 enable the connection of Remote access for
20 stations to the central station. 10 WinCC flexible 2008 clients;
single license for
10 remote access clients;
type of delivery:
CD, license key disk, Certificate of
License, Terms and Conditions
The number of licensed clients is
determined based on the amount of
installed SIMATIC logon remote
access licenses.

More information
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, we provide information on the Open Platform
Program for creating your own functions or Controls for
WinCC flexible.

3/74 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess

Overview Technical specifications


Option for SIMATIC WinCC flexible Runtime plus SIMATIC Type WinCC flexible /Sm@rtAccess
Panels for communication between various SIMATIC HMI
systems. The specifications are maximum
values
Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277 Execution platform
- TP 177B PN/DP, OP 177B PN/DP SIMATIC Panels Mobile Panel 177 PN,
Mobile Panel 277,
- TP 270, TP 277, OP 270, OP 277 TP/OP 177B PN/DP,
- MP 177, MP 270B, MP 277, MP 370, MP 377 TP/OP 270, TP/OP 277
- WinCC flexible Runtime SIMATIC Multi Panels MP 177, MP 270B, MP 277,
Communication between HMI systems is established on the MP 370, MP 377
basis of Ethernet networks, or via the intranet/Internet: PCs WinCC flexible Runtime
- Read and write access to variables Sm@rtAccess
- A SIMATIC HMI system can be used to control or monitor SIMATIC HMI HTTP protocol
another system remotely Number of connections for one client
Licensing: Mobile Panel 177 PN, 4
TP/OP 177 B PN/DP,
3
The license "WinCC flexible /Sm@rtAccess for Panel" or
MP 177 as HTTP server
"WinCC flexible/Sm@rtAccess for WinCC flexible Runtime"
Mobile Panel 277, TP/OP 270, 8
must be installed on both the server and client HMI device. TP/OP 277, MP 270B, MP 277,
Note: MP 370, MP 377 as HTTP server
for WinCC flexible Runtime 16
If the operator stations are accessed using the Sm@rtAccess
Sm@rtAccess
option, suitable protective measures (including IT security such Sm@rtClient concept
as network segmentation) should be taken in order to ensure
safe operation of the system. Number of Sm@rtClients that can
connect to a Sm@rtServer at the same
You will find more information on the topic of Industrial Security time1) 2)
on the Internet at: Mobile Panel 177 PN, 2 clients
TP/OP 177B PN/DP,
http://www.siemens.com/industrialsecurity MP 177 as Sm@rtServer
Mobile Panel 277, TP/OP 270, 3 clients for 6" devices
Ordering data Article No.
TP/OP 277, MP 270B,
MP 277 as Sm@rtServer
2 clients for 8" and 10" devices

MP 370, MP 377 as Sm@rtServer 3 clients for 12" devices


WinCC flexible /Sm@rtAccess for 2 clients for 15" devices
SIMATIC Panel 1) 1 client for 19" devices
Single license, 6AV6618-7AB01-3AB0 for WinCC flexible Runtime as 5 clients
license key only on USB stick Sm@rtServer
as download 2) 6AV6618-7AB01-3AH0 Number of Sm@rtClient displays
Single license, per screen
license key download only for Panels/Multi Panels 1
E-mail address required for the for WinCC flexible Runtime 2
delivery
1)
Including 1 Service Client
WinCC flexible /Sm@rtAccess for
2)
WinCC flexible 2008 Runtime 1) The Sm@rtServer and the WinCC flexible/Pro Agent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
Single license, 6AV6618-7AD01-3AB0 options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
license key only on USB stick context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
as download 2) 6AV6618-7AD01-3AH0 MP 377. Limitation: a maximum of 2 clients can be connected simultane-
Single license, ously to a Sm@rtServer.
license key download only
E-mail address required for the
delivery
More information
1)
The license must be installed on the server and on the client HMI device. Note
Server applications are the options Sm@rtServer, HTTP-Server and SOAP-
Server. Client applications are the screen object Sm@rtClient display, and
Do you need a specific modification or option for the products
the utilization of the communication driver HTTP protocol. A license is not described here? Then look up "Customized products", where
required for the engineering system for configuring the runtime option. you will find information about the Open Platform Program for the
2)
Current information and availability regarding the new delivery package creation of user-specific functions and controls for
can be found at: http://www.siemens.com/tia-online-software-delivery WinCC flexible.

Siemens ST 80 / ST PC 2016 3/75


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService

Overview Ordering data Article No.


Option for SIMATIC WinCC flexible Runtime and SIMATIC WinCC flexible /Sm@rtService for
Panels for remote maintenance and servicing of machines/ SIMATIC Panel 1)
plant via the Internet/intranet
Single license, 6AV6618-7BB01-3AB0
Available for the following SIMATIC HMI systems: license key only on USB stick
- Mobile Panel 177 PN, Mobile Panel 277
as download 2) 6AV6618-7BB01-3AH0
- TP 177B PN/DP, OP 177B PN/DP Single license,
- TP 270, TP 277, OP 270, OP 277 license key download only
- MP 177, MP 270B, MP 277, MP 370, MP 377 E-mail address required for the
- WinCC flexible Runtime delivery
Licensing WinCC flexible /Sm@rtService for
The "WinCC flexible /Sm@rtService for Panel" license or WinCC flexible 2008 Runtime 1)
"WinCC flexible /Sm@rtService for WinCC flexible Runtime" Single license, 6AV6618-7BD01-3AB0
license must be installed on the operator panels that use one license key only on USB stick
of the following options/functions: Sm@rtServer, HTML pages as download 2) 6AV6618-7BD01-3AH0
(mini-Web server), e-mail. Single license,
license key download only
3 Note:
If the operator stations are accessed using the Sm@rtService
E-mail address required for the
delivery
1)
option, suitable protective measures (including IT security such The "WinCC flexible/Sm@rtService for Panel" license or "WinCC flexible/
as network segmentation) should be taken in order to ensure Sm@rtService for WinCC flexible Runtime" license must be installed on the
safe operation of the system. operator panels that use one of the following options: Sm@rtServer, HTML
pages, e-mail. The remote service PC and engineering system do not
You will find more information on the topic of Industrial Security require a license for configuration of the Runtime option.
2)
on the Internet at: Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
http://www.siemens.com/industrialsecurity
More information
Application
Note
Remote maintenance and servicing of machines and plants
via Internet/Intranet Do you need a specific modification or option for the products
Calling of system information, control of target systems, and described here? Then look up "Customized products", where
updating of data sets via Internet/Intranet you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
Automatic sending of emails to experts for fast elimination of WinCC flexible.
faults

Technical specifications
Type WinCC flexible /Sm@rtService
Execution platform
SIMATIC Panels Mobile Panel 177 PN,
Mobile Panel 277, TP 177B PN/DP,
OP 177B PN/DP, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels MP 177, MP 270B, MP 277, MP 370,
MP 377
PCs SIMATIC WinCC flexible Runtime
Sm@rtService 1)
Remote access via Internet Explorer V6.0 SP1 and higher
HTML pages
for Panels/Multi Panels HTML V1.1 (no support for ActiveX,
Java, ASP)
for WinCC flexible Runtime HTML V1.1
Sending emails via SMTP server
Subject, message texts with
250 characters of text per email;
date/time of message, message no.
1)
The Sm@rtServer and the WinCC flexible/ProAgent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected with a
Sm@rtServer.

3/76 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /OPC-Server

Overview Ordering data Article No.


Option for SIMATIC WinCC flexible Runtime as well as Multi WinCC flexible /OPC-Server for
Panels for communication with applications from different SIMATIC Multi Panels 1)
vendors (e.g. MES, ERP, or applications in the office sector)
Single license, 6AV6618-7CC01-3AB0
Available for the following SIMATIC HMI systems: license key only on USB stick
- Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377
as download 2) 6AV6618-7CC01-3AH0
(use of OPC on XML basis) Single license,
- WinCC flexible Runtime (use of OPC based on DCOM) license key download only
One license is required for each operator station. E-mail address required for the
delivery
WinCC flexible /OPC-Server for
Application WinCC flexible Runtime 2008 1)
Single license, 6AV6618-7CD01-3AB0
OPC Foundation license key only on USB stick
as download 2) 6AV6618-7CD01-3AH0
http://www.opcfoundation.org Single license,
license key download only

Technical specifications
E-mail address required for the
delivery 3
1) One license is required for each operator station. A license is not required
Type WinCC flexible /OPC-Server for the engineering system for configuring the Runtime option.
2) Current information and availability regarding the new delivery package
The specifications are maximum
values can be found at: http://www.siemens.com/tia-online-software-delivery
Execution platform

More information
SIMATIC Panels Mobile Panel 277
SIMATIC Multi Panels MP 270B, MP 277, MP 370, MP 377
PCs SIMATIC WinCC flexible Runtime
Note
OPC-Server
XML server for Multi Panels Supports the OPC XML Data Access Do you need a specific modification or option for the products
specification V1.0 1) described here? Then look up "Customized products", where
DCOM server for WinCC flexible Supports the OPC Data Access you will find information about the Open Platform Program for the
Runtime specification V1.0a and V2.0 creation of user-specific functions and controls for
Number of connections that an 8 WinCC flexible.
OPC server can accommodate
1)
Data access via XML has a functional scope that is similar to OPC Data
Access. A software adapter is required that must be installed on the
OPC client PC to enable DCOM-based OPC clients to access the
OPC XML server without any modification. The software adapter is
supplied with WinCC flexible Engineering and Runtime.

Siemens ST 80 / ST PC 2016 3/77


Siemens AG 2016

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible options
WinCC flexible /ProAgent

Overview Ordering data Article No.


Targeted and rapid process diagnostics in plants and WinCC flexible /ProAgent for
machines for SIMATIC S7 and SIMATIC HMI SIMATIC Panels 1)
Standardized diagnostics concept for various SIMATIC executable on Mobile Panel 277,
components TP/OP/MP 270/277 and
No further configuration overhead for diagnostics functionality MP 370/377

Frees up PLC capacity with regard to memory and program Single license, 6AV6618-7DB01-3AB0
license key only on USB stick
execution time
as download 2) 6AV6618-7DB01-3AH0
Note: Single license,
For further information, refer to "SIMATIC ProAgent Process license key download only
Diagnostics Software". E-mail address required for the
delivery
WinCC flexible /ProAgent for
WinCC flexible Runtime 2008 1)
Single license, 6AV6618-7DD01-3AB0
license key only on USB stick
3 as download 2)
Single license,
6AV6618-7DD01-3AH0

license key download only


E-mail address required for the
delivery
1)
One license is required for each operator station. A license is not required
for the engineering system for configuring the Runtime option.
2)
Current information and availability regarding the new form of delivery can
be found at: http://www.siemens.com/tia-online-software-delivery

More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.

3/78 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
Introduction

Overview
SCADA System SIMATIC WinCC V7
The scalable and open SCADA system for maximum
plant transparency and productivity
Efficiency:
As a key to greater productivity, SIMATIC WinCC combines
efficient engineering with high-performance archiving and
maximum data security. With integrated diagnostics functions
and flexible production analysis, you shorten the time-to-
market and also reduce your plant standstill times.
SIMATIC WinCC is the basis for efficient operations
management and intelligent production analyses, so it offers a
secure basis for deciding on optimization measures, and thus
more productivity at lower cost.
Scalability:
With SIMATIC WinCC, it is possible to implement plants in all
industrial sectors and technologies, and easily expand or
modernize them by means of options or add-ons, in functional 3
SIMATIC WinCC terms or sector-specifically.
You can benefit from the redundancy concepts for enhanced
availability, or decide on centralized archiving and analysis of
plant information. SIMATIC WinCC offers stationary and
mobile solutions to cover increasing demands.
Innovation:
With innovative technology, you have all the important infor-
mation in view at all times. In this way, SIMATIC WinCC
simplifies intuitive operation and monitoring of the production
plant even remotely. Stay informed with mobile SCADA
solutions anywhere and at any time including with existing
tablet and smartphone hardware.
The use of multi-touch gestures in the industrial environment
opens the door to modern operator concepts.
Openness:
Since international standards and system-internal script and
programming interfaces are supported, special requests can
also be easily implemented.
SIMATIC WinCC backs cross-vendor communication for
integrating existing hardware, as well as for simple integration
into the IT world. WinCC Specialists are available worldwide
as qualified solution providers. These certified and centrally
audited partners are ready to implement your individual
SCADA project even in diversified client-server architectures
with redundancy, or in applications with energy data
management systems.
SIMATIC WinCC is designed to be independent of any
specific technology or industrial sector, modular in structure,
and easy to expand. It is used worldwide in single-user appli-
cations in mechanical engineering, as well as in complex
multi-user solutions with redundant servers or Web-based
client access. References from many industries prove the
versatility and performance capability.
http://www.siemens.com/wincc-v7

Siemens ST 80 / ST PC 2016 3/79


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Overview
Current versions:
SIMATIC WinCC V7.4
Executable with:
Windows 10 (64-bit) Professional, Enterprise
Windows 7 SP1 (32-bit/64-bit) Professional, Enterprise,
Ultimate
Windows 8.1 (32-bit/64-bit) Professional, Enterprise
Windows Server 2008 R2 SP1 (64-bit) Standard
Windows Server 2012 R2 (64-bit) Standard
Includes Microsoft SQL Server 2014 SP1 (32-bit)
SIMATIC WinCC V7.3
Executable with
3 Windows 7 SP1 (32-bit/64-bit) Professional, Enterprise,
Ultimate
Windows 8.1 (32-bit/64-bit) Professional, Enterprise
PC-based operator control and monitoring system for visual- Windows 2008 Server SP2 (32-bit) Standard
izing and operating processes, production flows, machines
and plants in all sectors from the simple single-user station Windows 2008 Server R2 SP1 (64-bit) Standard
through to distributed multi-user systems with redundant Windows Server 2012 R2 (64-bit) Standard
servers and cross-location solutions with Web clients. WinCC Includes Microsoft SQL Server 2008 R2 SP2 (32-bit)
is the information hub for corporation-wide vertical integration.
The basic system configuration (WinCC basic software) Use in virtual environments for more information see:
includes industry-standard functions for signaling and http://support.automation.siemens.com/WW/view/en/49370459
acknowledging events, archiving of messages and measured
values, logging of all process and configuration data, user http://www.siemens.com/wincc-v7
administration and visualization.
The WinCC basic software forms the core of a wide range of SIMATIC SCADA and SIMATIC IPCs
different applications. Based on the open programming inter-
faces, a wide range of WinCC options (from Siemens Industry Perfect interaction for optimum productivity.
Automation) and WinCC add-ons have been developed (by Price advantage as "Package" comprising hardware and
Siemens-internal and external partners). software
WinCC can be operated with every PC that meets the given System-tested solutions reduce testing overhead
HW requirements. The SIMATIC IPC product range is Simple ordering and synchronized logistics
available in particular for the industrial use of WinCC systems.
SIMATIC IPCs impress with their powerful PC technology, are
designed for round-the-clock operation, and can be operated Only if ordered together with the SIMATIC IPC.
in both office areas and harsh industrial environments.
WinCC/IndustrialDataBridge
Provider (data sources) Consumer (data destinations)
csv, txt
MS Excel 2003, 2007, 2010, 2013
MS Access 2003, 2007, 2010, 2013 MS Access 2003, 2007, 2010, 2013
MS SQL Server 2005, 2008, 2008 R2, MS SQL Server 2005, 2008, 2008 R2,
2012 2012
My SQL 3.5, 5.1, 5.5, 5.6 My SQL 3.5, 5.1, 5.5, 5.6
Oracle 8i, 10g, 11g, 12c release 2 Oracle 8i, 10g, 11g, 12c release 2
OPC Data Access 3.0 OPC Data Access 3.0
OPC XML 1.0 OPC XML 1.0
IDB OPC Server
Send/Receive Send/Receive
WinCC V7.2, V7.3 (via OLE DB) WinCC UserArchives V7.2, V7.3
WinCC UserArchives V7.2, V7.3
WinCC RT Professional V13 SP1 WinCC RT Professional V13 SP1
(via OLE DB) (via OLE DB)
Configurable TXT/ HTML

3/80 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Benefits
All-purpose New in V7.4
- Solutions for all sectors Supports Windows 10 Professional and Enterprise (64-bit)
- Multilingual for worldwide usage
- Can be integrated into all automation solutions Extended functionality for WinCC/WebUX
- Expansion to include additional controls
All operator control & monitoring functions on board - Dynamization can be implemented with VB script and
- User administration dynamic response dialog
- Operator control and monitoring
- Reporting, acknowledging, and archiving of events Expansion of the SIMATIC S7-1200 and
- Collecting, consolidating and archiving measured values S7-1500 communication channels
(including long-term backup) - Increased number of connections
- Logging and documenting of process and configuration (S7-1500 with up to 128 connections)
data - Transmission of byte data blocks
Can be configured simply and efficiently Easier configuration with WinCC Configuration Studio
- Configuration wizards let the user focus on the essentials - Efficient engineering with "drag-and-drop"
- In the picture by means of cross-reference lists and screen - VBA in the WinCC Configuration Studio
property displays Simplified runtime operation
- Configuration of multilingual applications
- Configuring tool for configuring bulk data
- Touch operation in runtime (zoom and pan within "right click"
controls)
3
Universally scalable - Adapt "Favorites" system dialog in Runtime
- Expandable from single station to client-server configura- - Control toolbar size is configurable
tions Uniform license model for WinCC/DataMonitor,
- Increased availability by means of redundant servers WinCC/WebNavigator and WinCC/WebUX.
- Process visualization via the Web with the WinCC Version-independent packages can be cumulated, and
WebNavigator or WebUX WebNavigator and WebUX licenses can be combined
Open standards for simple integration Extended functionality for the WinCC Graphics Designer
- Powerful real-time database Microsoft SQL Server 2008 R2 Introduction of new controls (BarChartControl for displaying
SP2 (32-bit) archive tags in a bar chart, and SysDiagControl for system
- Open for application modules with ActiveX controls diagnostics of S7-1200/1500 controllers)
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication New "OPC UA WinCC Channel" communication channel
Process visualization with Plant Intelligence Remote maintenance via Remote Desktop Protocol
- Integrated evaluation functions for the online analysis and more ...
(statistical process control)
- Production optimization with the help of diverse options New in V7.3
Expandable using options and add-ons Expansion into Graphic Designer
- Options for scalable configurations - Support of SVG image objects and Direct2D
- Options for increasing the availability Expansion of WinCC Configuration Studio
- Options for IT & business integration (configuration options as in Excel)
- Options for SCADA expansions - Alarm Logging
- Options for validation in accordance with - Tag Logging
FDA 21 CFR Part 11 - User Archive
- Options for the use of telecontrol protocols - Text Library
Part of Totally Integrated Automation Expansion of communication channels
- Direct access to the tag and message configuration of the - Communication channel to new CPU (S7-1200 / S7-1500)
SIMATIC control system (support of symbolic address and CPU alarming)
- Integrated diagnostic functions for increasing productivity - OPC UA Server A&C (Alarm & Condition)
Encrypted communication
- SSL encryption for communication of terminal bus
Multi-user engineering for integrated projects
and more ...

Siemens ST 80 / ST PC 2016 3/81


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Application WinCC editors Task or configurable runtime functionality


WinCC Explorer Central project management for the quick
SIMATIC WinCC is designed for visualization and operation of access to all project data and central
processes, manufacturing cycles, machines and plants. With its settings
powerful process interface, especially to the SIMATIC family, WinCC Graphics Designer Graphics system for user-defined visualiza-
and the secure data archiving, WinCC enables highly available tion and operation via pixel-graphic objects
solutions for the process control.
WinCC Configuration Studio Alarm Logging
The sector-neutral basic system enables universal usage in all Signaling system for detecting and archiving
automation applications. Sector-specific solutions can, for ex- events with display and control options
ample, be implemented using WinCC options (e.g. FDA options based on DIN 19235; freely selectable
message classes, message display and
for the pharmaceutical industry) and sector-specific add-ons logging
(e.g. for the water industry).
WinCC Tag Logging

Design Process archiving for the acquisition, com-


pression and storage of measured values,
e.g., presentation in trend and table format
SIMATIC WinCC is available as a complete package and as a as well as further processing
runtime package with 128, 512, 2 048, 8 192, 65 536, 102 400, WinCC User Administrator

3
153 600, 262 144 PowerTags. PowerTags are data points that are
For managing users and authorizations
connected to controllers or other data sources over a WinCC
channel. Up to 32 alarms can be obtained from one data point. WinCC Report Designer Reporting and logging system for time and
Moreover, internal tags without coupling are available for addi- event-controlled documentation of
messages, operator inputs and current
tional system performance. In addition WinCC also contains process data in the form of user reports or
512 archive tags. Additional archive licenses can be obtained project documentation in an arbitrary layout
for larger quantity structures.
WinCC Global Script Processing functions with limitless
Licenses for a multi-user configuration functionality by means of the use of VBScript
and ANSI-C
The system software with the required number of PowerTags and
additionally the option WinCC/Server must be installed on the Interfaces
WinCC server. In the basic configuration, one RT Client License
Task or configurable runtime functionality
is sufficient for the WinCC Clients 1). An RC Client License is
required to configure on clients 1). Remote configuration is Communication channels For communication with subordinate controls
possible if WinCC Clients without their own project (Uni Client) (SIMATIC protocols, PROFIBUS DP,
PROFIBUS FMS, DDE and OPC server
are configured on the server project. included in the scope of delivery)
1) Standard interfaces For the open integration of other Windows
The SQL Server Express is installed for RT / RC Clients. applications via WinCC, WinCC-OLE-DB,
ActiveX, OLE, DDE, OPC, etc.)

Function Programming ports For the individual access to data and func-
tions of WinCC and for the integration in user
programs with VBA, VB Script, C-API (ODK),
The powerful configuration functions of SIMATIC WinCC contrib- C-Script (ANSI-C)
ute to a reduced engineering and training overhead and lead to
a more flexible use of personnel and greater operational reliabil-
ity.
Anyone familiar with Microsoft Windows can also operate the
WinCC Explorer, the central switching point of WinCC.
Even large quantities of data can be processed intuitively and
efficiently with the WinCC Configuration Studio.
In combination with other SIMATIC components, the system is
also equipped with auxiliary functions, such as process diag-
nostics and maintenance. All SIMATIC engineering tools work
together in the configuration of the functions.
SIMATIC WinCC offers a complete basic functionality for
process visualization and operation. To this end WinCC has a
number of editors and interfaces that can be used to individually
configure this functionality according to the respective
application. Expansions of a WinCC station for control tasks
are also possible with minimal engineering effort.

3/82 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration
Integration in company-wide solutions Number of connectable controllers
(IT and business integration)
For the number of controllers which can be connected via
WinCC is based on Microsoft technology, which ensures open- Industrial Ethernet CP 1613, the following applies to a message
ness and integration capability. ActiveX and .net controls facili- frame length of 512 bytes:
tate technology-specific and industry-specific expansions.
Cross-manufacturer communication is also possible since Type of connection Number of nodes
WinCC can be used as an OPC client and server in addition to SIMATIC S5 Ethernet Layer 4 up to 60
accessing current process values and supporting standards + TCP/IP
such as OPC HDA (Historical Data Access), OPC Alarm & SIMATIC S7 Protocol Suite up to 64
Events, OPC XML Data Access, and OPC UA.
SIMATIC 505 Ethernet Layer 4 up to 60
Just as important: Visual Basic for Applications (VBA) is avail- + TCP/IP up to 128
able for user-specific expansions in engineering and Visual OMS+
Basic Scripting (VBS) as an easy-to-learn, open, runtime
language. If desired, professional application developers can Via PROFIBUS, a maximum of 8 controllers can be connected
also use ANSI-C. The Open Development Kit (ODK) simplifies with CP 5612, and a maximum of 44 controllers with CP 5613.
access to the API programming interfaces.
WinCC integrates a powerful and scalable archiving functional-
Industrial Ethernet is recommended when 10 or more controllers
are used. 3
ity based on Microsoft SQL Server 2014 SP1 into the basic Mixed operation with different controllers
system. This gives the user multiple and varied options: With their multi-protocol stack, the CP 1613 and CP 5613
from high-performance archiving of current process data, communication processors enable the parallel operation of two
to long-term archiving with high data compression, through to protocols, such as for the mixed operation of different control-
a connection to the central information hub in the form of a lers, via a single bus cable. WinCC supports the operation of two
company-wide process historian. Versatile clients and tools similar interface boards only in connection with the channels
for evaluation, the open interfaces, and special options SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7
(Connectivity Pack, Connectivity Station, IndustrialDataBridge) Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as
provide the basis for effective IT and business integration. PROFIBUS DP (4 x CP 5613; max. 122 slaves for each
WinCC offers various security mechanisms, such as encrypted CP 5613). In addition to communication via Industrial Ethernet
communication, to ensure secure operation of the plant. If exter- CP 1613 or PROFIBUS CP 5613, one CP 5612/5622 can be used
nal networks are accessed, for example, suitable protective in each case for communication with SIMATIC S7 via MPI.
measures (incl. IT security measures, such as network segmen-
tation) should still also be taken. Client-server communication

You can find more information on the topic of Industrial Security Communication between the clients and the server is via TCP/IP
on the Internet at: protocol. Setting up a separate PC LAN is recommended. For
small projects with a correspondingly low incidence of message
http://www.siemens.com/industrialsecurity frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server PLC)
Integration in automation solutions and PC-PC communication (WinCC/client WinCC/server).
WinCC is an open process visualization system and provides the Channel DLL PROFIBUS DP
option to connect the most diverse control systems.
In accordance with the PROFIBUS standard, DP/slaves are
Approved communication software always permanently assigned to a DP master; i.e. a second
Use communication software with the listed product versions WinCC station (DP/master) cannot access the same controllers
(or higher). Corresponding SIMATIC NET upgrades are available (DP/slaves). This means that redundant operation of two WinCC
for upgrading older versions. stations is not possible using the PROFIBUS DP connection.

Siemens ST 80 / ST PC 2016 3/83


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Connection to controllers from other manufacturers:
If a native driver is not available, OPC (OLE for process control) WinCC supports the standards:
is available for connection to third-party controllers. OPC Data Access 2.05a
Current notes and information about OPC servers from various OPC Data Access 3.00
suppliers can be found at: OPC XML Data Access 1.00 (Connectivity Pack/Connectivity
http://www.opcfoundation.org Station)
OPC HDA 1.20 (Connectivity Pack/Connectivity Station)
OPC A&E 1.10 (Connectivity Pack/Connectivity Station)
OPC UA Client Data Access
OPC UA Server Data Access, HDA, Alarm & Condition
(Connectivity Pack / Connectivity Station)

Connection overview
3 Protocol Description Protocol Description
SIMATIC S7 Third-party controllers
SIMATIC S7 Protocol Suite Channel DLL for S7 functions via MPI, Allen Bradley Channel DLL and drivers for
PROFIBUS or Ethernet Layer 4 + Ethernet IP communication with Allen Bradley
TCP/IP controllers via Ethernet TCP/IP using
Ethernet IP protocol
SIMATIC S5
Modbus TCP/IP Channel DLL and drivers for
SIMATIC S5 Ethernet Layer 4 Channel DLL for communication with Modicon
S5 Layer 4 communication + TCP/IP controllers via Ethernet TCP/IP using
SIMATIC S5 Programmer Port AS511 Channel DLL and driver for Modbus TCP/IP protocol
serial communication with S5 using Mitsubishi MC TCP/IP Channel DLL and drivers for
AS511 protocol to programmers port communication with Mitsubishi
SIMATIC S5 Serial 3964R Channel DLL and driver for controllers via Ethernet TCP/IP using
serial communication with S5 using Mitsubishi MC TCP/IP protocol
RK512 protocol Cross-manufacturer
SIMATIC S5 PROFIBUS-FDL Channel DLL for S5-FDL OPC Client for DA, XML DA Channel DLL for
SIMATIC 505 OPC communication,
WinCC can acquire data from
SIMATIC 505 Serial Channel DLL and driver for OPC server applications.
serial communication with 505 using
NITP/TBP protocol to OPC Server for DA, XML DA, A&E, Server applications for
SIMATIC 535/545/555/565/575 HDA OPC communication;
WinCC provides process data to
SIMATIC 505 Ethernet Layer 4 Channel DLL for OPC Clients
505 Layer 4 communication
OPC UA server for DA, HDA, A&C Server applications for
SIMATIC 505 TCP/IP Channel DLL for OPC UA communication
505 TCP/IP communication
PROFIBUS FMS Channel DLL for PROFIBUS FMS
SIMATIC S7-1200, S7-1500
PROFIBUS DP Channel DLL for PROFIBUS DP
SIMATIC S7-1200, S7-1500 Channel Channel DLL for
S7-1200 and S7-1500 communication SIMOTION Channel DLL for SIMOTION

Application note:
Parallel usage of the OPC client channel allows, for example,
connection to an SNMP-OPC server for visualization of the data
contained there. The SNMP OPC server enables monitoring of
any network components (such as switches) that support the
SNMP protocol. You can find more information under SIMATIC
NET Communications Systems/SNMP OPC Server.

3/84 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.4)
Industrial Ethernet SIMATIC S5 SIMATIC S5 SIMATIC S7 SIMATIC 505 SIMATIC 505 Article No.
Ethernet TCP/IP Protocol Ethernet TCP/IP 1)
Layer 4 Suite Layer 4
WinCC channel DLL
SIMATIC S5 Ethernet Layer 4 Included in the basic
Channel DLL for package
S5 Layer 4 communication + TCP/IP
SIMATIC S7 Protocol Suite Included in the basic
Channel DLL for S7 functions package
SIMATIC 505 Ethernet Layer 4 Included in the basic
Channel DLL for 505 Layer 4 communication package
SIMATIC 505 TCP/IP 1) Included in the basic
Channel DLL for 505 TCP/IP communication package
Communication components for extension of the OS/OP
CP 1612 A2
PCI card for connecting a PG/PC to
6GK1161-2AA01 3
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communication software
must be ordered separately)
SOFTNET-IE S7 6GK1704-1CW13-0AA0
communication software for
S7 functions (max. 64 connections)
Version 13 SP2 2)3)
for Windows 7 SP1 (32/64-bit), Windows 8.1
(32/64-bit), Windows 2008 R2 SP1 Server,
Server 2012 R2 (64-bit), and
Windows 10 (64-bit)
SOFTNET-IE S7 Lean 6GK1704-1LW13-0AA0
communication software for
S7 functions (max. 8 connections)
Version 13 SP2 2)3)
for Windows 7 SP1 (32/64-bit), Windows 8.1
(32/64-bit), Windows 2008 R2 SP1 Server,
Server 2012 R2 (64-bit), and
Windows 10 (64-bit)
CP 1613 A2 6GK1161-3AA01
PCI card (32-bit) for connecting a PG/PC to
Industrial Ethernet (S7-1613 communication
software required)
CP 1623 6GK1162-3AA00
PCI Express X1 card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(S7-1613 communication software required)
CP 1628 6GK1162-8AA00
PCI Express X1 card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(HARDNET-IE S7 / S7-1613 communication
software required)
HARDNET-IE S7 / S7-1613 6GK1716-1CB13-0AA0
communication software for S7 functions,
OPC, PG/OP communication
Version 13 SP2 2)3)
for Windows 7 SP1 (32/64-bit), Windows 8.1
(32/64-bit), Windows 2008 R2 SP1 Server,
Server 2012 R2 (64-bit), and
Windows 10 (64-bit)

System interface possible

1)
Via any interface board with NDIS 3.0 interface; no separate communi-
cation software required
2)
See ordering data for SIMATIC NET upgrade packages
3)
SIMATIC NET Version 12 SP2 is supplied together with WinCC V7.4
4)
SOFTNET-S7 Lean is included in the scope of supply of WinCC V7.4

Siemens ST 80 / ST PC 2016 3/85


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.4)
PROFIBUS SIMATIC S5 SIMATIC S7 PROFIBUS DP PROFIBUS FMS Article No.
PROFIBUS FDL Protocol Suite
WinCC channel DLL
SIMATIC S5 PROFIBUS FDL Included in the basic
Channel DLL for S5-FDL package
SIMATIC S7 Protocol Suite Included in the basic
Channel DLL for S7 functions package
PROFIBUS DP Included in the basic
Channel DLL for PROFIBUS DP package
Communication components for extension of the OS/OP
CP 5612 2) 6GK1561-2AA00
PCI card (32-bit) for connecting a PG/PC
to PROFIBUS (communication software
included in WinCC basic package)
3 CP 5622 2)
PCI Express X1 card (32-bit) for
6GK1562-2AA00

connecting a PG/PC to PROFIBUS


(communication software included in
WinCC basic package)
CP 5711 6GK1571-1AA00
USB adapter for connecting a PG/PC to
PROFIBUS or MPI
(communication software included in
WinCC basic package)
CP 5613 A3 6GK1561-3AA02
PCI card (32-bit) for connecting a PC to
PROFIBUS (S7-5613, DP-5613 or
FMS-5613 communication software
required)
CP 5614 A3 6GK1561-4AA02
PCI card (32-bit) for connecting a PC to
PROFIBUS (communication software
must be ordered separately)
CP 5623 6GK1562-3AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (HARDNET PB S7 or
HARDNET PB DP communication
software required)
HARDNET PB S7 6GK1713-5CB08-2AA0
Communication software for
S7 functions + FDL
Version 8.2 SP1 1)2)
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
HARDNET PB DP 6GK1713-5DB08-2AA0
Communication software for
DP master + FDL
Version 8.2. SP1 1)2) for Windows 7
(32/64-bit) and Server 2008 R2 (64-bit)

System interface possible

1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1 is supplied together with WinCC V7.4

3/86 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.3)
Industrial Ethernet SIMATIC S5 SIMATIC S5 SIMATIC S7 SIMATIC 505 SIMATIC 505 Article No.
Ethernet TCP/IP Protocol Ethernet TCP/IP 1)
Layer 4 Suite Layer 4
WinCC channel DLL
SIMATIC S5 Ethernet Layer 4 Included in the basic
Channel DLL for package
S5 Layer 4 communication + TCP/IP
SIMATIC S7 Protocol Suite Included in the basic
Channel DLL for S7 functions package
SIMATIC 505 Ethernet Layer 4 Included in the basic
Channel DLL for 505 Layer 4 communication package
SIMATIC 505 TCP/IP 1) Included in the basic
Channel DLL for 505 TCP/IP communication package
Communication components for extension of the OS/OP
CP 1612 A2
PCI card for connecting a PG/PC to Industrial
6GK1161-2AA01 3
Ethernet (SOFTNET-S7 or SOFTNET-S7 Lean
communication software must be ordered
separately)
SOFTNET-IE S7
communication software for
S7 functions (max. 64 connections)
Version 8.2 SP1 2)3) 6GK1704-1CW08-2AA0
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
Edition 2008 SP6 (V7.1) 2) 6GK1704-1CW71-3AA0
for Windows XP/2003 Server/(32-bit) 2008
Server
SOFTNET-IE S7 Lean
communication software for S7 functions
(max. 8 connections)
Version 8.2 SP1 2) 4) 6GK1704-1LW08-2AA0
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
Edition 2008 SP6 (V7.1) 2) 4) 6GK1704-1LW71-3AA0
for Windows XP/2003 Server / (32-bit) 2008
Server
CP 1613 A2 6GK1161-3AA01
PCI card (32-bit) for connecting a PG/PC to
Industrial Ethernet
(S7-1613 communication software required)
CP 1623 6GK1162-3AA00
PCI Express X1 card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(S7-1613 communication software required)
CP 1628 6GK1162-8AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to Industrial Ethernet
(HARDNET-IE S7 / S7-1613 communication
software required)
HARDNET-IE S7 / S7-1613
communication software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
Version 8.2 SP1 2)3) 6GK1716-1CB08-2AA0
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
Edition 2008 SP6 (V7.1) 2) 6GK1716-1CB71-3AA0
for Windows XP/2003 Server / (32-bit) 2008
Server

System interface possible

1)
Via any interface board with NDIS 3.0 interface; no separate communi-
cation software required
2)
See ordering data for SIMATIC NET upgrade packages
3)
SIMATIC NET Version 8.2 SP1 is supplied together with WinCC V7.3
4)
SOFTNET S7 Lean included in scope of supply of WinCC V7.3

Siemens ST 80 / ST PC 2016 3/87


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.3)
PROFIBUS SIMATIC S5 SIMATIC S7 PROFIBUS DP PROFIBUS FMS Article No.
PROFIBUS FDL Protocol Suite
WinCC channel DLL
SIMATIC S5 PROFIBUS FDL Included in the basic
Channel DLL for S5-FDL package
SIMATIC S7 Protocol Suite Included in the basic
Channel DLL for S7 functions package
PROFIBUS DP Included in the basic
Channel DLL for PROFIBUS DP package
PROFIBUS FMS Included in the basic
Channel DLL for PROFIBUS FMS package
Communication components for extension of the OS/OP
CP 5612 2) 6GK1561-2AA00

3 PCI card (32-bit) for connecting a PG/PC


to PROFIBUS (communication software
included in WinCC basic package)
CP 5622 2) 6GK1562-2AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communication software included in
WinCC basic package)
CP 5711 6GK1571-1AA00
USB Adapter for connecting a PG/PC to
PROFIBUS or MPI (communications
software included in the WinCC basic
package)
CP 5613 A3 6GK1561-3AA02
PCI card (32-bit) for connecting
a PC to PROFIBUS (S7-5613, DP-5613 or
FMS-5613 communication software
required)
CP 5614 A3 6GK1561-4AA02
PCI card (32-bit) for connecting
a PC to PROFIBUS (communication
software must be ordered separately)
CP 5623 6GK1562-3AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (S7-5613 communication software or
DP-5613 or FMS-5613 required)
HARDNET PB S7
Communication software for
S7 functions + FDL
Version 8.2 SP1 1)2) 6GK1713-5CB08-2AA0
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
Edition 2008 SP6 (V7.1) 1) 2) 6GK1713-5CB71-3AA0
for Windows XP/2003 Server / (32-bit)
2008 Server
HARDNET PB DP
Communication software for
DP master + FDL
Version 8.2. SP1 1)2) 6GK1713-5DB08-2AA0
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
Edition 2008 SP6 (V7.1) 1) 2) 6GK1713-5DB71-3AA0
for Windows XP/2003 Server / (32-bit)
2008 Server
FMS-5613 6GK1713-5FB71-3AA0
communication software for
PROFIBUS-FMS + FDL
Edition 2008 SP6 (V7.1) 1) 2)
for Windows XP/2003 Server / (32-bit)
2008 Server

System interface possible

1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1 is supplied together with WinCC V7.3

3/88 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Communication examples

SIMATIC NET PROFIBUS (S7 functions)

Standard PC with WinCC - CP 5613 A2/A3


e.g. RC 64 k or RT 64 k - CP 5623
- HARDNET-PB S7
(communication software)

PROFIBUS

SIMATIC S7-400 SIMATIC S7-300

- CP 443-5 Extended - CP 342-5 (DP, S7, S/R)


(DP/M, S7, S/R) - CP 343-5 (FMS, S7, S/R)
- CP 443-5 Basis (FMS, S7, S/R)

- NCM S7 manual PROFIBUS - NCM S7 manual PROFIBUS

G_ST80_XX_00010
(SIMATIC NET CD/DVD or (SIMATIC NET CD/DVD or
Internet download) Internet download )

WinCC single-user system: PROFIBUS with S7 communication

SIMATIC NET Industrial Ethernet (S7 functions)

- CP 1613 A2
Standard PC with WinCC 6GK1161-3AA01
e.g. RC 64 k or RT 64 k - CP 1623
6GK1162-3AA00
- S7-1613
(communication software)
6GK1716-1CB80-3AA0

Industrial Ethernet

SIMATIC S7-400 SIMATIC S7-300

- CP 443-1 (S7, S/R) ISO + TCP - CP 343-1 (S7, S/R) ISO + TCP
6GK7443-1EX30-0XE0 6GK7343-1EX30-0XE0
- CP 443-1 Advanced - CP 343-1 Advanced
(S7, S/R, HTTP) (S7, S/R, HTTP)
6GK7443-1GX30-0XE0 6GK7343-1GX31-0XE0
G_ST80_XX_00011

- NCM S7 manual Industrial Ethernet - NCM S7 manual Industrial Ethernet


(SIMATIC NET CD or (SIMATIC NET CD or
Internet download) Internet download)

WinCC single-user system: Industrial Ethernet with S7 communication

Siemens ST 80 / ST PC 2016 3/89


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)

SIMATIC NET PROFIBUS-FMS

- CP 5613 A2
Standard PC 6GK1561-3AA00
with WinCC - CP 5623
e.g. RC 64 k or RT 64 k 6GK1562-3AA00
+ FMS channel DLL - FMS-5613
(communication software)
6GK1713-5FB71-3AA0

PROFIBUS FMS

3
SIMATIC S7-300 SIMATIC S7-400 SIMATIC
- CP 343-5 - CP 443-5 Basic S5-115/135/155U
(FMS, S7, S/R) (FMS, S7, S/R)
6GK7343-5FA01-0XE0 6GK7443-5FX02-0XE0
- CP 5431 FMS/DP
6GK1543-1AA01

G_ST80_XX_00012
- COM 5431 FMS/DP
6GK1745-1AD00-0EA0

WinCC single-user system: PROFIBUS FMS

without operator controls: + TCP/IP 4 clients max.


32 clients + 3 web clients interface with operator
or module controls
Standard PC 150 web clients + 1 client
with WinCC
e.g. RC 64 k or RT 64 k Client Client

Server TERMINAL BUS TCP/IP

PROCESS BUS (Industrial Ethernet/PROFIBUS)

SIMATIC S7-400 SIMATIC S7-300

This allows you to set up the following application examples


- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions
G_ST80_XX_00013

- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions


- WinCC single-user system: SIMATIC NET PROFIBUS-FMS

WinCC multi-user system with operable server

3/90 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Integration (continued)
Higher-level visualisation system
- OPC server functionality
(included in WinCC basic package)
- TCP-IP interface board required

OPC Client

Industrial Ethernet
- OPC Server functionality
- OPC Server On-site visualization (included in WinCC
functionality OPC Server OPC Server
basic package)
(OPC Server - TCP-IP Interface board
option for required
WinCC
required) 3
OPC Client
- integrated - OPC Client
OPC Server
PROFIBUS PROFIBUS functionality (included
interface in WinCC basic
SIMATIC SIMATIC
package)
S7-300 S7-400
- OPC Server required
third-party for interfacing with
PLCs

G_ST80_XX_00015
third-party PLCs

OPC link

Siemens ST 80 / ST PC 2016 3/91


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Technical specifications
Type SIMATIC WinCC V7.4 3) SIMATIC WinCC V7.3
Operating system Windows 10 (64-bit) Professional, Enterprise Windows 7 (32-bit / 64-bit) Ultimate, Professional and
Windows 7 (32-bit / 64-bit) Ultimate, Professional and Enterprise
Enterprise Windows 8.1 (32-bit / 64-bit) Professional and Enterprise
Windows 8.1 (32-bit / 64-bit) Professional and Enterprise Windows Server 2008 SP2 (32-bit) Standard
Windows Server 2008 R2 SP1 (64-bit) Standard Windows 2008 Server R2 SP1 (64-bit) Standard
Windows Server 2012 R2 (64-bit) Standard Windows Server 2012 R2 (64-bit) Standard
PC hardware requirements
Processor type 1)
Minimum Single-user station/server: Dual-core; 2.5 GHz 2) Single-user station/server: Pentium 4; 2.5 GHz 2)
2)
Client: Dual-core; 2.5 GHz Client: Pentium 3; 1 GHz 2)
Web client: Dual-core; 2 GHz WebClient/DataMonitor Client: Pentium III, 600 MHz 2)
Recommended Single-user station/server: Multi-core; 3.5 GHz 2) Single-user station/server: Pentium 4 or dual-core;
3 GHz 2)
3 Client: Multi-core; 3 GHz 2) Client: Pentium 4, 2 GHz 2)
Web client: Dual-core; 3 GHz WebClient/DataMonitor Client: Pentium III, 1 GHz
RAM
Minimum Windows 7/ Windows 8.1 (32-bit) Single-user station / server: 8 GB 2)
Single-user station/server: 2 GB
Client: 1 GB
Web client: 1 GB
Windows 7/ Windows 8.1/ Windows 10 (64-bit) Client: 4 GB 2)
Single-user station/server: 4 GB
Client: 2 GB
Web client: 1 GB
Windows Server 2008 R2/ Windows Server 2012 R2 WebClient/DataMonitor Client: 512 MB 2)
Server: 4 GB
Recommended Windows 7/ Windows 8.1 (32-bit) Single-user station / server: 16 GB 2)
Single-user station/server: 3 GB
Client: 2 GB
Web client: 2 GB
Windows 7/ Windows 8.1/ Windows 10 (64-bit) Client: 8 GB 2)
Single-user station/server: 4 GB
Client: 4 GB
Web client: 2 GB
Windows Server 2008 R2/ Windows Server 2012 R2 WebClient/DataMonitor Client: 1 GB 2)
Server: 8 GB
Graphics card
Minimum 16 MB, 800 x 600 2) 16 MB, 800 x 600 2)
Recommended 32 MByte, 1 920 x 1 080 2) 32 MB, 1 280 x 1 024 2)
Hard disk
Minimum Single-user station/server: 80 GB Single-user station/server: 80 GB
Client: 20 GB Client: 20 GB
WebClient/DataMonitor Client: 5 GB WebClient/DataMonitor Client: 5 GB
Recommended Single-user station/server: 160 GB Single-user station/server: 160 GB
Client: 40 GB Client: 40 GB
WebClient/DataMonitor Client: 10 GB WebClient/DataMonitor Client: 10 GB
Hard disk
(available memory for installation)
- Minimum Server: > 1.5 GB

Client: 1.5 GB
- Recommended Server: > 10 GB

Client: > 1.5 GB


CD-ROM/DVD-ROM/disk drive/USB port For software installation For software installation
1)
An AMD system with comparable performance can also be used
2) Hardware requirements when using Microsoft XP Professional
3) Please refer to the relevant catalog for technical specifications of older
WinCC versions

3/92 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Technical specifications (continued)


Type SIMATIC WinCC V7.4 Type SIMATIC WinCC V7.4
Functionality/ PowerTags 256 K 3)
quantity structure
Trends
Number of messages 150,000 Trend views per image 25
Message text 10 x 256 Trends per trend view 80
(number of characters)
Message archive System-limited 1) User administration
Process values per message 10 User groups 128
Constant load of messages, Server/single-user station: 10/s Number of users 128
max. Authorization groups 999
Message burst, max. Server/single-user station: 2,000/10 s every Configuration languages 5 European (Eng., Fr., Ger., It., Sp.),
5 min 4 Asian (simpl.+trad. Chi/Kor/Jpn)
Archives Protocols
Archive data points Max. 80,000 per server 2) Message sequence reports 1 per server/single-user station
Archive types Short-term archive with and without (simultaneously)
long-term archiving Message archive reports
3
3
Data storage format Microsoft SQL Server 2014 SP1 (simultaneously)
Measured values per second, Server/single-user station: 5 000/s User reports System-limited 1)
max. Report lines per group 66
User archive Tags per report 300 5)
Total archives No limit Multi-user system
Fields per user archive 500 (maximum number of 1 000 000 fields) Server 18
Data records per user archive 10 000 Uni Client max. 64
User archive views No limit (without its own project)
Graphics system Multi-Client max. 50
(with its own project)
Number of screens System-limited 1)
Number of objects per screen System-limited 1)
Number of controllable fields System-limited 1)
per screen
1) Dependent on the available storage space
2) Dependent on the number of licensed archive tags (ArchiveTags)
3) Dependent on the number of licensed PowerTags
4) The number of tags per report is dependent on the process communi-
cation performance

Ordering data Article No. Article No.

SIMATIC WinCC system software Complete packages on DVD


V7.4 Language versions:
De, En, Fr, It, Es; with license for
Runtime packages on DVD WinCC RC Client 6AV6381-2CB07-4AX0
Incl. 512 archive tags each; 128 PowerTags (RC 128) 6AV6381-2BM07-4AX0
language/script versions: 512 PowerTags (RC 512) 6AV6381-2BN07-4AX0
De, En, Fr, It, Es; with license for
2 048 PowerTags (RC 2 048) 6AV6381-2BP07-4AX0
WinCC RT Client 6AV6381-2CA07-4AX0
8 192 PowerTags (RC 8 192) 6AV6381-2BS07-4AX0
128 PowerTags (RT 128) 6AV6381-2BC07-4AX0
65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-4AX0
512 PowerTags (RT 512) 6AV6381-2BD07-4AX0
102 400 PowerTags (RC 102 400) 6AV6381-2BT07-4AX0
2 048 PowerTags (RT 2 048) 6AV6381-2BE07-4AX0
153 600 PowerTags (RC 153 600) 6AV6381-2BU07-4AX0
8 192 PowerTags (RT 8 192) 6AV6381-2BH07-4AX0
262 144 PowerTags (RC 262 144) 6AV6381-2BV07-4AX0
65 536 PowerTags (RT 65 536) 6AV6381-2BF07-4AX0
102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-4AX0 as download
153 600 PowerTags (RT 153 600) 6AV6381-2BK07-4AX0 WinCC RC Client 6AV6381-2CB07-4AH0
262 144 PowerTags (RT 262 144) 6AV6381-2BL07-4AX0 128 PowerTags (RC 128) 6AV6381-2BM07-4AH0
512 PowerTags (RC 512) 6AV6381-2BN07-4AH0
as download
2 048 PowerTags (RC 2 048) 6AV6381-2BP07-4AH0
WinCC RT Client 6AV6381-2CA07-4AH0
8 192 PowerTags (RC 8 192) 6AV6381-2BS07-4AH0
128 PowerTags (RT 128) 6AV6381-2BC07-4AH0
65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-4AH0
512 PowerTags (RT 512) 6AV6381-2BD07-4AH0
102 400 PowerTags (RC 102 400) 6AV6381-2BT07-4AH0
2 048 PowerTags (RT 2 048) 6AV6381-2BE07-4AH0
153 600 PowerTags (RC 153 600) 6AV6381-2BU07-4AH0
8 192 PowerTags (RT 8 192) 6AV6381-2BH07-4AH0
262 144 PowerTags (RC 262 144) 6AV6381-2BV07-4AH0
65 536 PowerTags (RT 65 536) 6AV6381-2BJ07-4AH0
102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-4AH0
153 600 PowerTags (RT 153 600) 6AV6381-2BK07-4AH0
262 144 PowerTags (RT 262 144) 6AV6381-2BL07-4AH0

Siemens ST 80 / ST PC 2016 3/93


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


V7.4 ASIA incl. update 1 V7.4 Archive
Runtime packages on DVD 1 500 archive tags (countable) 6AV6371-1DQ17-4AX0
5 000 archive tags (countable) 6AV6371-1DQ17-4BX0
Incl. 512 archive tags each; 10 000 archive tags (countable) 6AV6371-1DQ17-4CX0
language/script versions:
En, Chs, Cht, Kor, Jpn; 30 000 archive tags (countable) 6AV6371-1DQ17-4EX0
with license for as download
WinCC RT Client 6AV6381-2CA07-4AV0 1 500 archive tags (countable) 6AV6371-1HQ17-4AX0
128 PowerTags (RT 128) 6AV6381-2BC07-4AV0 5 000 archive tags (countable) 6AV6371-1HQ17-4BX0
512 PowerTags (RT 512) 6AV6381-2BD07-4AV0 10 000 archive tags (countable) 6AV6371-1HQ17-4CX0
2 048 PowerTags (RT 2 048) 6AV6381-2BE07-4AV0 30 000 archive tags (countable) 6AV6371-1HQ17-4EX0
8 192 PowerTags (RT 8 192) 6AV6381-2BH07-4AV0
SIMATIC WinCC Upgrades/
65 536 PowerTags (RT 65 536) 6AV6381-2BF07-4AV0 Software Update Service
102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-4AV0
153 600 PowerTags (RT 153 600) 6AV6381-2BK07-4AV0 SIMATIC WinCC V7.4 upgrade 1)
262 144 PowerTags (RT 262 144) 6AV6381-2BL07-4AV0 For upgrading the RT version
From V7.X to V7.4 6AV6381-2AA07-4AX3
3
Complete packages on DVD
Language versions: From V7.X ASIA to V7.4 ASIA 2) 6AV6381-2AA07-4AV3
En, Chs, Cht, Kor, Jpn; as download
with license for
From V7.X to V7.4 6AV6381-2AA07-4AK3
WinCC RC Client 6AV6381-2CB07-4AV0
128 PowerTags (RC 128) 6AV6381-2BM07-4AV0 For upgrading the RC version
512 PowerTags (RC 512) 6AV6381-2BN07-4AV0 From V7.X to V7.4 6AV6381-2AB07-4AX3
2 048 PowerTags (RC 2 048) 6AV6381-2BP07-4AV0 From V7.X ASIA to V7.4 ASIA 2) 6AV6381-2AB07-4AV3
8 192 PowerTags (RC 8 192) 6AV6381-2BS07-4AV0 as download
65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-4AV0 From V7.X to V7.4 6AV6381-2AB07-4AK3
102 400 PowerTags (RC 102 400) 6AV6381-2BT07-4AV0 For upgrading the Client RT
153 600 PowerTags (RC 153 600) 6AV6381-2BU07-4AV0 version
262 144 PowerTags (RC 262 144) 6AV6381-2BV07-4AV0 From V7.X to V7.4 6AV6381-2CA07-4AX3
V7.4 Powerpacks From V7.X ASIA to V7.4 ASIA 6AV6381-2CA07-4AV3
For upgrading from: as download
From V7.X to V7.4 6AV6381-2CA07-4AK3
Runtime packages
128 to 512 PowerTags 6AV6371-2BD07-4AX0 For upgrading the Client RC
512 to 2 048 PowerTags 6AV6371-2BG07-4AX0 version
2 048 to 8 192 PowerTags 6AV6371-2BM07-4AX0 From V7.X to V7.4 6AV6381-2CB07-4AX3
8 192 to 65 536 PowerTags 6AV6371-2BN07-4AX0 From V7.X ASIA to V7.4 ASIA 6AV6381-2CB07-4AK3
65 536 to 102 400 PowerTags 6AV6371-2BP07-4AX0 as download
102 400 to 153 600 PowerTags 6AV6371-2BQ07-4AX0 From V7.X to V7.4 6AV6381-2CB07-4AV3
153 600 to 262 144 PowerTags 6AV6371-2BR07-4AX0 SIMATIC WinCC Software Update
as download Service (SUS) 3) 4) 5)
128 to 512 PowerTags 6AV6371-2BD07-4AJ0 SIMATIC WinCC V7 Update
512 to 2 048 PowerTags 6AV6371-2BG07-4AJ0 Software Update Service for
2 048 to 8 192 PowerTags 6AV6371-2BM07-4AJ0 WinCC basic software and options:
8 192 to 65 536 PowerTags 6AV6371-2BN07-4AJ0 1 license 6AV6381-1AA00-0AX5
65 536 to 102 400 PowerTags 6AV6371-2BP07-4AJ0 3 licenses 6AV6381-1AA00-0BX5
102 400 to 153 600 PowerTags 6AV6371-2BQ07-4AJ0 10 licenses 6AV6381-1AA00-0CX5
153 600 to 262 144 PowerTags 6AV6371-2BR07-4AJ0 as download
Complete packages 1 license 6AV6381-1KA00-0AX5
128 to 512 PowerTags 6AV6371-2BD17-4AX0 3 licenses 6AV6381-1KA00-0BX5
512 to 2 048 PowerTags 6AV6371-2BG17-4AX0 10 licenses 6AV6381-1KA00-0CX5
2 048 to 8 192 PowerTags 6AV6371-2BM17-4AX0
8 192 to 65 536 PowerTags 6AV6371-2BN17-4AX0
65 536 to 102 400 PowerTags 6AV6371-2BP17-4AX0
102 400 to 153 600 PowerTags 6AV6371-2BQ17-4AX0
1) According to licensing provisions, 1 upgrade package must be ordered for
153 600 to 262 144 PowerTags 6AV6371-2BR17-4AX0
each WinCC station
as download 2) Upgrading from V7.X RT/RC ASIA to V7.4 ASIA is carried out using the
128 to 512 PowerTags 6AV6371-2BD17-4AJ0 "respective non-Asia package"
512 to 2 048 PowerTags 6AV6371-2BG17-4AJ0 3) The Software Update Service is valid for 1 year. The contract is
2 048 to 8 192 PowerTags 6AV6371-2BM17-4AJ0 automatically extended by 1 more year unless canceled 3 months prior to
8 192 to 65 536 PowerTags 6AV6371-2BN17-4AJ0 expiration. According to licensing provisions, 1 Software Update Service
65 536 to 102 400 PowerTags 6AV6371-2BP17-4AJ0 must be ordered for each WinCC station.
102 400 to 153 600 PowerTags 6AV6371-2BQ17-4AJ0 4) Requires the current software version
153 600 to 262 144 PowerTags 6AV6371-2BR17-4AJ0 5) SUS is available as download

3/94 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


V7.3 SE incl. Update 1 V7.3 ASIA SE incl. update 1
Runtime packages on DVD Runtime packages on DVD
Incl. 512 archive tags each; Incl. 512 archive tags each;
language/script versions: language/script versions:
Ger, En, Fr, It, Sp; En, Chs, Cht, Kor, Jpn;
with license for with license for
WinCC RT Client 6AV6381-2CA07-3AX0 WinCC RT Client 6AV6381-2CA07-3AV0
128 PowerTags (RT 128) 6AV6381-2BC07-3AX0 128 PowerTags (RT 128) 6AV6381-2BC07-3AV0
512 PowerTags (RT 512) 6AV6381-2BD07-3AX0 512 PowerTags (RT 512) 6AV6381-2BD07-3AV0
2 048 PowerTags (RT 2 048) 6AV6381-2BE07-3AX0 2 048 PowerTags (RT 2 048) 6AV6381-2BE07-3AV0
8 192 PowerTags (RT 8 192) 6AV6381-2BH07-3AX0 8 192 PowerTags (RT 8 192) 6AV6381-2BH07-3AV0
65 536 PowerTags (RT 65 536) 6AV6381-2BF07-3AX0 65 536 PowerTags (RT 65 536) 6AV6381-2BF07-3AV0
102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-3AX0 102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-3AV0
153 600 PowerTags (RT 153 600) 6AV6381-2BK07-3AX0 153 600 PowerTags (RT 153 600) 6AV6381-2BK07-3AV0
262 144 PowerTags (RT 262 144) 6AV6381-2BL07-3AX0 262 144 PowerTags (RT 262 144) 6AV6381-2BL07-3AV0
as download Complete packages on DVD
Including 512 archive tags each
WinCC RT Client 6AV6381-2CA07-3AH0
Language versions:
En, Chs, Cht, Kor, Jpn; 3
with license for
128 PowerTags (RT 128) 6AV6381-2BC07-3AH0 WinCC RC Client 6AV6381-2CB07-3AV0
512 PowerTags (RT 512) 6AV6381-2BD07-3AH0 128 PowerTags (RC 128) 6AV6381-2BM07-3AV0
2 048 PowerTags (RT 2 048) 6AV6381-2BE07-3AH0 512 PowerTags (RC 512) 6AV6381-2BN07-3AV0
8 192 PowerTags (RT 8 192) 6AV6381-2BH07-3AH0 2 048 PowerTags (RC 2 048) 6AV6381-2BP07-3AV0
65 536 PowerTags (RT 65 536) 6AV6381-2BF07-3AH0 8 192 PowerTags (RC 8 192) 6AV6381-2BS07-3AV0
102 400 PowerTags (RT 102 400) 6AV6381-2BJ07-3AH0 65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-3AV0
153 600 PowerTags (RT 153 600) 6AV6381-2BK07-3AH0 102 400 PowerTags (RC 102 400) 6AV6381-2BT07-3AV0
262 144 PowerTags (RT 262 144) 6AV6381-2BL07-3AH0 153 600 PowerTags (RC 153 600) 6AV6381-2BU07-3AV0
Complete packages on DVD 262 144 PowerTags (RC 262 144) 6AV6381-2BV07-3AV0
Language versions: V7.3 Powerpacks
De, En, Fr, It, Es;
with license for For upgrading from:
WinCC RC Client 6AV6381-2CB07-3AX0 Runtime packages
128 PowerTags (RC 128) 6AV6381-2BM07-3AX0 128 to 512 PowerTags 6AV6371-2BD07-3AX0
512 PowerTags (RC 512) 6AV6381-2BN07-3AX0 512 to 2 048 PowerTags 6AV6371-2BG07-3AX0
2 048 PowerTags (RC 2 048) 6AV6381-2BP07-3AX0 2 048 to 8 192 PowerTags 6AV6371-2BM07-3AX0
8 192 PowerTags (RC 8 192) 6AV6381-2BS07-3AX0 8 192 to 65 536 PowerTags 6AV6371-2BN07-3AX0
65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-3AX0 65 536 to 102 400 PowerTags 6AV6371-2BP07-3AX0
102 400 PowerTags (RC 102 400) 6AV6381-2BT07-3AX0 102 400 to 153 600 PowerTags 6AV6371-2BQ07-3AX0
153 600 PowerTags (RC 153 600) 6AV6381-2BU07-3AX0 153 600 to 262 144 PowerTags 6AV6371-2BR07-3AX0
262 144 PowerTags (RC 262 144) 6AV6381-2BV07-3AX0
as download
as download 128 to 512 PowerTags 6AV6371-2BD07-3AJ0
WinCC RC Client 6AV6381-2CB07-3AH0 512 to 2 048 PowerTags 6AV6371-2BG07-3AJ0
128 PowerTags (RC 128) 6AV6381-2BM07-3AH0 2 048 to 8 192 PowerTags 6AV6371-2BM07-3AJ0
512 PowerTags (RC 512) 6AV6381-2BN07-3AH0 8 192 to 65 536 PowerTags 6AV6371-2BN07-3AJ0
2 048 PowerTags (RC 2 048) 6AV6381-2BP07-3AH0 65 536 to 102 400 PowerTags 6AV6371-2BP07-3AJ0
8 192 PowerTags (RC 8 192) 6AV6381-2BS07-3AH0 102 400 to 153 600 PowerTags 6AV6371-2BQ07-3AJ0
65 536 PowerTags (RC 65 536) 6AV6381-2BQ07-3AH0 153 600 to 262 144 PowerTags 6AV6371-2BR07-3AJ0
102 400 PowerTags (RC 102 400) 6AV6381-2BT07-3AH0
153 600 PowerTags (RC 153 600) 6AV6381-2BU07-3AH0
262 144 PowerTags (RC 262 144) 6AV6381-2BV07-3AH0

Siemens ST 80 / ST PC 2016 3/95


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


Complete packages SIMATIC WinCC Upgrades/
128 to 512 PowerTags 6AV6371-2BD17-3AX0 Software Update Service
512 to 2 048 PowerTags 6AV6371-2BG17-3AX0 SIMATIC WinCC V7.3 upgrade 1)
2 048 to 8 192 PowerTags 6AV6371-2BM17-3AX0
For upgrading the RT version
8 192 to 65 536 PowerTags 6AV6371-2BN17-3AX0
From V6.2/7.0 to V7.3 6AV6381-2AA07-3AX4
65 536 to 102 400 PowerTags 6AV6371-2BP17-3AX0
From V7.2 to V7.3 6AV6381-2AA07-3AX3
102 400 to 153 600 PowerTags 6AV6371-2BQ17-3AX0
From V6.2 ASIA to V7.3 ASIA 2) 6AV6381-2AA07-3AV4
153 600 to 262 144 PowerTags 6AV6371-2BR17-3AX0
From V7.2 ASIA to V7.3 ASIA 6AV6381-2AA07-3AV3
as download
as download
128 to 512 PowerTags 6AV6371-2BD17-3AJ0
From V6.2/7.0 to V7.3 6AV6381-2AA07-3AK4
512 to 2 048 PowerTags 6AV6371-2BG17-3AJ0
From V7.2 to V7.3 6AV6381-2AA07-3AK3
2 048 to 8 192 PowerTags 6AV6371-2BM17-3AJ0
8 192 to 65 536 PowerTags 6AV6371-2BN17-3AJ0 For upgrading the RC version
65 536 to 102 400 PowerTags 6AV6371-2BP17-3AJ0 From V6.2/7.0 to V7.3 6AV6381-2AB07-3AX4
102 400 to 153 600 PowerTags 6AV6371-2BQ17-3AJ0 From V7.2 to V7.3 6AV6381-2AB07-3AX3
From V6.2 ASIA to V7.3 ASIA 2) 6AV6381-2AB07-3AV4
3
153 600 to 262 144 PowerTags 6AV6371-2BR17-3AJ0
From V7.2 ASIA to V7.3 ASIA 6AV6381-2AB07-3AV3
V7.3 Archives
1 500 Archive Tags 6AV6371-1DQ17-3AX0 as download
5 000 Archive Tags 6AV6371-1DQ17-3BX0 From V6.2/7.0 to V7.3 6AV6381-2AB07-3AK4
10 000 Archive Tags 6AV6371-1DQ17-3CX0 From V7.2 to V7.3 6AV6381-2AB07-3AK3
30 000 Archive Tags 6AV6371-1DQ17-3EX0 For upgrading the Client RT
80 000 Archive Tags 6AV6371-1DQ17-3GX0 version
From V6.2 to V7.3 6AV6381-2CA07-3AX4
as download
1 500 Archive Tags 6AV6371-1HQ17-3AX0 From V7.0/7.2 to V7.3 6AV6381-2CA07-3AX3
From V6.2 ASIA to V7.3 ASIA 6AV6381-2CA07-3AV4
5 000 Archive Tags 6AV6371-1HQ17-3BX0
10 000 Archive Tags 6AV6371-1HQ17-3CX0 From V7.0/7.2 ASIA to V7.3 ASIA 6AV6381-2CA07-3AV3
30 000 Archive Tags 6AV6371-1HQ17-3EX0 as download
80 000 Archive Tags 6AV6371-1HQ17-3GX0 From V6.2 to V7.3 6AV6381-2CA07-3AK4
From V7.0/7.2 to V7.3 6AV6381-2CA07-3AK3
V7.3 Archive Powerpacks
For upgrading archiving from For upgrading the Client RC
version
1 500 to 5 000 Archive Tags 6AV6371-1DQ17-3AB0
From V7.x to V7.3 6AV6381-2CB07-3AX3
5 000 to 10 000 archive tags 6AV6371-1DQ17-3BC0
From V7.X ASIA to V7.3 ASIA 2) 6AV6381-2CB07-3AV3
10 000 to 30 000 Archive Tags 6AV6371-1DQ17-3CE0
30 000 to 80 000 Archive Tags 6AV6371-1DQ17-3EG0 as download
From V7.x to V7.3 6AV6381-2CB07-3AK3
as download
1 500 to 5 000 Archive Tags 6AV6371-1JQ17-3AB0 SIMATIC WinCC Software Update
Service (SUS) 3) 4) 5)
5 000 to 10 000 archive tags 6AV6371-1JQ17-3BC0
10 000 to 30 000 Archive Tags 6AV6371-1JQ17-3CE0 SIMATIC WinCC V7 Update
30 000 to 80 000 Archive Tags 6AV6371-1JQ17-3EG0 Software Update Service for
WinCC basic software and options:
1 license 6AV6381-1AA00-0AX5
3 licenses 6AV6381-1AA00-0BX5
10 licenses 6AV6381-1AA00-0CX5
as download
1 license 6AV6381-1KA00-0AX5
3 licenses 6AV6381-1KA00-0BX5
10 licenses 6AV6381-1KA00-0CX5
SIMATIC WinCC V7.3 SE S79220-B5964-P
incl. Update 1
DVD WinCC V7.3 SE incl. Update 1

1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
Upgrading from V7.0 RT/RC ASIA to V7.3 ASIA is carried out using the
"respective non-Asia package"
3)
The Software Update Service is valid for 1 year. The contract is automati-
cally extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.
4)
Requires the current software version
5)
SUS is available as download

3/96 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


SIMATIC WinCC V7.4 communication
Communication via HARDNET IE S7 V13 SP2
Industrial Ethernet / PROFIBUS Software for S7-compatible and
CP 1612 A2 6GK1161-2AA01 S5-compatible communication
incl. OPC server,
PCI card (32-bit) for connection of a PG/OP communication and
PG/PC to Industrial Ethernet NCM PC, single license for
(10/100/1000 Mbps) with RJ45 one installation of Runtime software,
connection via SOFTNET S7 and software and electronic manual
SOFTNET PG. on CD-ROM, license key on
Windows 8.1 and Windows 2012 USB flash drive, Class A
Server are not supported. for CP 1613 A2, CP 1623, CP 1628;
SOFTNET IE S7 Version 13 SP2 English/German
Software for S7-compatible and Single license for 1 installation 6GK1716-1CB13-0AA0
S5-compatible communication Upgrade package for SIMATIC 6GK1716-1CB00-3AE0
incl. OPC server, NET Edition 2006 or higher
PG/OP communication and Upgrade package for SIMATIC 6GK1716-1CB00-3AE1
NCM PC; up to 64 connections; NET V6.0, V6.1, V6.2 and
single license for one installation of
Runtime software, software and
Edition 2005
Communication via PROFIBUS
3
electronic manual on CD-ROM;
license key on USB flash drive; CP 5612 6GK1561-2AA00
Class A for CP 1612 A2
English/German PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (
Single license for 1 installation 6GK1704-1CW13-0AA0 communication software included
Upgrade package for 6GK1704-1CW00-3AE0 in WinCC Basic package).
SIMATIC NET Edition 2006 or
higher CP 5622 6GK1562-2AA00
Upgrade package for 6GK1704-1CW00-3AE1 PCI Express X1 card (32-bit) for
SIMATIC NET V6.0, V6.1, V6.2 and connecting a PG/PC to PROFIBUS
Edition 2005 (communication software included
in WinCC Basic package)
SOFTNET IE S7 Lean
Version 13 SP2 CP 5711 6GK1571-1AA00
(license included in scope of USB adapter for connecting a
delivery of WinCC V7.4) PG/PC to PROFIBUS or MPI
Software for S7-compatible and (communication software included
S5-compatible communication in WinCC Basic package)
including OPC server, CP 5613 A3 6GK1561-3AA02
PG/OP communication and
NCM PC; PCI card (32-bit) for connecting a
up to 8 connections; single license PC to PROFIBUS
for one installation of runtime (communication software must be
software, software and electronic ordered separately)
manual on CD-ROM, license key on CP 5614 A3 6GK1561-4AA02
USB flash drive, Class A,
PCI card (32-bit) for connecting a
for CP 1612 A2, English/German
PC to PROFIBUS
Single license for 1 installation 6GK1704-1LW13-0AA0 (communication software must be
Upgrade package for 6GK1704-1LW00-3AE0 ordered separately)
SIMATIC NET Edition 2006 or
higher CP 5623 6GK1562-3AA00
Upgrade package for 6GK1704-1LW00-3AE1 PCI Express X1 card (32-bit) for
SIMATIC NET V6.0, V6.1, V6.2 and connection of PG/PC to Industrial
Edition 2005 Ethernet (communication software
must be ordered separately)
CP 1613 A2 6GK1161-3AA01
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(communication software must be
ordered separately)
CP 1623 6GK1162-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communication software
must be ordered separately)
CP 1628 6GK1162-8AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to Ind.
Ethernet (communication software
must be ordered separately)

Siemens ST 80 / ST PC 2016 3/97


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


HARDNET PB S7 V8.2 SP1 HARDNET PB DP V13 SP2
Software for S7 communication Software for DP protocol
incl. PG/OP communication, FDL, incl. PG/OP communication, FDL,
OPC server, Runtime software, DP OPC server, Runtime software,
software and electronic manual on software and electronic manual on
CD-ROM, license key on USB flash CD-ROM,
drive, Class A License key on USB flas drive,
for CP 5613 A3, CP 5614 A3, Class A
CP 5623 for CP 5613 A3, CP 5614 A3,
English/German CP 5623 English/German
Single license for 1 installation 6GK1713-5CB08-2AA0 Single license for 1 installation 6GK1713-5DB13-0AA0
Upgrade package for 6GK1713-5CB00-3AE0 Upgrade package for 6GK1713-5DB00-3AE0
SIMATIC NET Edition 2006 or SIMATIC NET Edition 2006 or
higher higher
Upgrade package for 6GK1713-5CB00-3AE1 Upgrade package for 6GK1713-5DB00-3AE1
SIMATIC NET V6.0, V6.1, V6.2 and SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005 Edition 2005
HARDNET PB S7 V13 SP2 FMS 5613 V7.1 SP6
3 Software for S7 communication
incl. PG/OP communication, FDL,
(Edition 2008 + SP6)
Software for FMS protocol
OPC server, Runtime software, incl. PG/OP communication, FDL,
software and electronic manual on OPC server, Runtime software,
CD-ROM, license key on USB flash software and electronic manual on
drive, Class A CD-ROM, license key on USB flash
for CP 5613 A3, CP 5614 A3, drive, Class A,
CP 5623 for CP 5613 A2, CP 5614 A2,
English/German CP 5623; English/German
Single license for 1 installation 6GK1713-5CB13-0AA0 Single license for 1 installation 6GK1713-5FB71-3AA0
Upgrade package for SIMATIC 6GK1713-5CB00-3AE0 Upgrade package for 6GK1713-5FB00-3AE0
NET Edition 2006 or higher SIMATIC NET Edition 2006 or
Upgrade package for 6GK1713-5CB00-3AE1 higher
SIMATIC NET V6.0, V6.1, V6.2 and Upgrade package for 6GK1713-5FB00-3AE1
Edition 2005 SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

3/98 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. Article No.


SIMATIC WinCC V7.3 communication
Communication via Industrial HARDNET-IE S7 V13 SP2 1)
Ethernet / PROFIBUS Software for S7-compatible and
CP 1612 A2 6GK1161-2AA01 S5-compatible communication
incl. OPC server,
PCI card (32-bit) for connection of a PG/OP communication and
programming device or NCM PC,
PC to Industrial Ethernet single license for one installation of
(10/100/1000 Mbps) with runtime software,
RJ45 connection via SOFTNET S7 software and electronic manual on
and SOFTNET PG. Windows 8.1 CD-ROM,
and Windows 2012 Server are not license key on USB flash drive,
supported. Class A
SOFTNET-IE S7 Version 13 SP2 1) for CP 1613 A2, CP 1623, CP 1628;
Software for S7-compatible and English/German
S5-compatible communication incl. Single license for 1 installation 6GK1716-1CB13-0AA0
OPC server, PG/OP communication Upgrade package for 6GK1716-1CB00-3AE0
and NCM PC; up to 64 connections; SIMATIC NET Edition 2006 or
single license for one installation of
Runtime software, software and
higher
Upgrade package for 6GK1716-1CB00-3AE1
3
electronic manual on CD-ROM; SIMATIC NET V6.0, V6.1, V6.2 and
license key on USB stick; Class A Edition 2005
for CP 1612-A2 English/German
Single license for 1 installation 6GK1704-1CW13-0AA0 Communication via PROFIBUS
Upgrade package for SIMATIC 6GK1704-1CW00-3AE0 CP 5612 2) 6GK1561-2AA00
NET Edition 2006 or higher PCI card (32-bit) for connecting a
Upgrade package for SIMATIC 6GK1704-1CW00-3AE1 PG/PC to PROFIBUS
NET V6.0, V6.1, V6.2 and Edition (communications software included
2005 in the WinCC basic package).
SOFTNET-IE S7 Lean CP 5622 2) 6GK1562-2AA00
Version 13 SP2 1) PCI Express X1 card (32-bit) for
(license included in scope of connecting a PG/PC to PROFIBUS
delivery of WinCC V7.4/V7.3) (communications software included
Software for S7 and S5-compatible in WinCC Basic package)
communication including OPC
server, PG/OP communication and CP 5711 6GK1571-1AA00
NCM PC; up to 8 connections; USB adapter for connecting a
single license for one installation of PG/PC to PROFIBUS or MPI
runtime software, software and (communications software included
electronic manual on CD-ROM, in WinCC Basic package)
License Key on USB stick, Class A, CP 5613 A3 6GK1561-3AA02
for CP 1612-A2, English/German
PCI card (32-bit) for connecting a
Single license for 1 installation 6GK1704-1LW13-0AA0
PC to PROFIBUS
Upgrade package for 6GK1704-1LW00-3AE0 (communications software must be
SIMATIC NET Edition 2006 or ordered separately)
higher
Upgrade package for 6GK1704-1LW00-3AE1 CP 5614 A3 6GK1561-4AA02
SIMATIC NET V6.0, V6.1, V6.2 and PCI card (32-bit) for connecting a
Edition 2005 PC to PROFIBUS
(communications software must be
CP 1613 A2 6GK1161-3AA01 ordered separately)
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet CP 5623 6GK1562-3AA00
(communications software must be PCI Express X1 card (32-bit) for
ordered separately) connection of PG/PC to Industrial
Ethernet (communications software
CP 1623 6GK1162-3AA00 must be ordered separately)
PCI Express X1 card (32-bit) for
1)
connection of PG/PC to Industrial The SIMATIC NET PC software delivered with SIMATIC WinCC V7.3 must
Ethernet (communications software always be used. The scope of supply for WinCC V7.3 includes the
must be ordered separately) SIMATIC NET PC software V12 SP2 / supported operating systems:
32/64-bit Windows 7 SP1 Professional, Ultimate, 32/64-bit Windows 8.1,
CP 1628 6GK1162-8AA00 64-bit Windows 2008 Server R2 SP2, 64-bit Windows 2012 Server R2 and
PCI Express X1 card (32-bit) for SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) / supported
connecting a PG/PC to Ind. operating systems: Windows 2012 Server R2 (64-bit), Windows 7 SP1 (
Ethernet (communication software 32-bit/64-bit) Professional, Enterprise, Ultimate, Windows Server 2008
must be ordered separately) Standard. Only use the license from the product package of the above
listed SIMATIC NET PC software products. Licenses supplied with
SIMATIC NET V12 SP2 are valid for all older versions as of Edition 2006.
Windows 2003, Windows XP and VISTA are no longer supported.
2)
Only for WinCC single-user system / supported operating systems:
32/64-bit Windows 7 Professional, Ultimate

Siemens ST 80 / ST PC 2016 3/99


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC V7

Ordering data Article No. More information


HARDNET-PB S7 V8.2 SP1 1) WinCC language versions
Software for S7 communication incl.
PG/OP communication, FDL,
SIMATIC WinCC is also offered in simplified Chinese, traditional
OPC server, Runtime software, Chinese, Korean and Japanese especially for Asian markets.
software and electronic manual on These WinCC versions are intended for machine manufacturers,
CD-ROM, license key on USB stick, plant constructors and exporters who supply the regions of
Class A China, Taiwan, Korea and Japan.
for CP 5613-A2, CP 5614-A2,
CP 5623 WinCC ASIA includes all familiar WinCC functions and offers in
English/German addition the configuration user interface in the respective
Single license for 1 installation 6GK1713-5CB08-2AA0 national language and English. The online help is available in
Upgrade package for 6GK1713-5CB00-3AE0 simplified Chinese, traditional Chinese, Korean, Japanese and
SIMATIC NET Edition 2006 or
higher
English. A Chinese, Korean, Japanese or multilingual Windows
Upgrade package for 6GK1713-5CB00-3AE1
operating system is required for operation.
SIMATIC NET V6.0, V6.1, V6.2 and The runtime licenses are language-neutral. The English handling
Edition 2005
program (Automation License Manager ALM) is executable
HARDNET-PB S7 V13 SP2 1)
3
under the Chinese, Korean and Japanese Windows versions.
Software for S7 communication incl.
PG/OP communication, FDL, In order to use the Asian languages in WinCC, an Asia hardware
OPC server, Runtime software, dongle is required.
software and electronic manual on
CD-ROM, license key on USB stick, Additional information is available on the Internet at:
Class A
for CP 5613-A2, CP 5614-A2, http://www.siemens.com/wincc
CP 5623
English/German http://www.siemens.com/wincc-v7
Single license for 1 installation 6GK1713-5CB13-0AA0 IPC packages
Upgrade package for 6GK1713-5CB00-3AE0
SIMATIC NET Edition 2006 or There are attractive packages available with SIMATIC Rack PCs
higher (IPC347, IPC547, IPC647, IPC847), SIMATIC Box PCs (IPC227,
Upgrade package for 6GK1713-5CB00-3AE1 IPC427, IPC627, IPC827) and SIMATIC Panel PCs (IPC277,
SIMATIC NET V6.0, V6.1, V6.2 and IPC477, IPC677) for a completely matched software and
Edition 2005
hardware package. These IPCs can be configured in different
HARDNET-PB DP V13 SP2 1) ways for use as single station, server or client.
Software for DP protocol incl.
PG/OP communication, FDL, Downloads:
DP OPC server, Runtime software,
software and electronic manual on In most cases, the products can also be obtained as software
CD-ROM, license key on USB stick, downloads.
Class A,
for CP 5613-A2, CP 5614-A2, Additional information on Online Software Delivery is available
CP 5623; English/German here:
Single license for 1 installation 6GK1713-5DB13-0AA0
http://www.automation.siemens.com/mcms/topics/en/simatic/
Upgrade package for 6GK1713-5DB00-3AE0
SIMATIC NET Edition 2006 or online-software-delivery/pages/default.aspx
higher
Upgrade package for 6GK1713-5DB00-3AE1
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
FMS-5613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for FMS protocol incl.
PG/OP communication, FDL,
OPC server, Runtime software,
software and electronic manual on
CD ROM, License Key on
USB stick, Class A;
For CP 5613-A2, CP 5614-A2,
CP 5623; English/German
Single license for 1 installation 6GK1713-5FB71-3AA0
Upgrade package for 6GK1713-5FB00-3AE0
SIMATIC NET Edition 2006 or
higher
Upgrade package for 6GK1713-5FB00-3AE1
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
1)
The SIMATIC NET PC software delivered with SIMATIC WinCC V7.3 must
always be used. The scope of supply for WinCC V7.3 includes the
SIMATIC NET PC software V12 SP2 / supported operating systems:
32/64-bit Windows 7 SP1 Professional, Ultimate, 32/64-bit Windows 8.1,
64-bit Windows 2008 Server R2 SP2, 64-bit Windows 2012 Server R2 and
SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) / supported
operating systems: Windows 2012 Server R2 (64-bit), Windows 7 SP1
(32-bit/64-bit) Professional, Enterprise, Ultimate, Windows Server 2008
Standard. Only use the license from the product package of the above
listed SIMATIC NET PC software products. Licenses supplied with
SIMATIC NET V12 SP2 are valid for all older versions as of Edition 2006.
Windows 2003, Windows XP and VISTA are no longer supported.

3/100 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
Introduction

Overview Options for greater efficiency in operations management


SIMATIC Information Server
Web-based, integrated reporting from production to
management, based on archived data
http://www.siemens.com/simatic-information-server
WinCC/Calendar Scheduler
Calendar-based planning of events
WinCC/ChangeControl
- Change and version management
- Generation of audit trails for engineering
WinCC/Audit
- Change management
- Generation of audit trails for engineering and runtime
WinCC/DataMonitor
For displaying and evaluating current process states and
historical data on office PCs with standard tools

3
WinCC/Event Notifier
For sending of notifications triggered by specific events in the
WinCC message system
WinCC/PerformanceMonitor
The universal WinCC basic software is the basis for modular Analysis and optimization of production on the basis of
expansions. These functional expansions can be obtained in the individual performance indicators
form of WinCC options and as WinCC Premium add-ons. WinCC/SES (Sequence Execution System)
WinCC options are created by WinCC Development and are Sie- Scalable sequence control for sequence-based processes
mens Industry Automation products. You can obtain support WinCC/User Archives
from our Advisory Services and via the central hotline. For managing data records in user archives
Options for scalable plant configurations Options for openness and individual system expansions
SIMATIC Process Historian WinCC/Connectivity Pack
Central, scalable long-term archive for the whole plant Access to WinCC logs via OPC HDA, OPC A&E,
http://www.siemens.com/wincc-process-historian OPC XML Server, OPC UA Server/Client and
WinCC/Redundancy WinCC OLE-DB /OLE-DB
For increasing system availability through redundancy WinCC/Connectivity Station
WinCC/Server Gateway to WinCC server data via OPC HDA, OPC A&E,
For configuring a powerful client/server system OPC XML server, OPC UA Server/Client,
and WinCC OLE-DB /OLE-DB from independent computers
WinCC/TeleControl
For connecting outlying stations (remote terminal units = WinCC/IndustrialDataBridge
RTUs) via telecontrol protocols in a WinCC SCADA system Configurable connection to databases and IT systems
http://www.siemens.com/industrial-data-bridge
WinCC/WebNavigator
For controlling and monitoring plants via the Internet, in-house WinCC/ODK (Open Development Kit)
intranet or LAN For the use of open programming interfaces and the gener-
ation of customer-specific WinCC ActiveX objects
WinCC/WebUX
For controlling and monitoring plants, independent of You can find more information under:
platforms and browsers, via the Internet, in-house intranet or
LAN http://www.siemens.com/simatic-wincc-options

More information
WinCC options
http://www.siemens.com/wincc-options

Siemens ST 80 / ST PC 2016 3/101


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
SIMATIC Information Server

Overview

Microsoft Office
Dashboard WinCC (Excel/ Word / Powerpoint)
Dashboard PCS 7
Information Information
Server Server
Information
Server
SIMATIC
Information Server

WinCC reports

3
WinCC V7
PCS 7 systems
systems

G_ST80_XX_00594
WinCC RT
Professional
systems

Information Server 2014 SP2


Information Server 2014 SP2 is an open, Web-based reporting Reports can be integrated directly in Word and Excel, thus
system for interactive areas. Reports can be used in Internet greatly simplifying work steps.
Explorer, Excel, Word or PowerPoint, as well as for Adobe Process values can be displayed in tabular or graphic form
Reader (PDF). depending on various filter functions
SIMATIC Information Server has access to archived process
values and messages, and can be used either directly in Support of subscriptions for cyclic report generation including
conjunction with WinCC / WinCC/RT Professional / PCS7 OS as e-mail service
well as with Process Historian 2014 SP2. Performance increase through automatic aggregation
Access to archived process values and messages from: Web-based creation and provision of reports
- WinCC V7.2 UD 4, V7.3 Second Edition UD 1 and V7.4 Use of the standard tools MS Excel, MS Word and
- WinCC/Performance Monitor V7.3 or V7.4 MS PowerPoint for individual report templates
- WinCC RT Professional V13 SP1
- PCS7 V8.0 SP1, V8.0 SP2 and V8.1 Reporting system based on MS Reporting Services for more
complex individual report templates
Process Historian 2014 SP2
Can be used for HTML5-enabled tablet PCs larger than 10.5"
Open reporting system with report templates for both inter-
active online reports (Web-based) and printed documents Automatic cyclic and event-based reporting
(PDF) (PDF, Excel, Word, PowerPoint)
Thanks to the add-in technology for Microsoft Office environ- Central storage and automatic transmission of reports created
ments, simple and direct access is established to the archived by e-mail
Process Historian database. Data security thanks to access protection, user administration,
SSL encryption and SMTP authentication

3/102 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
SIMATIC Information Server

Overview (continued) Benefits


Operating systems, browsers, MS Office, virtualization Central, web-based reporting system as an interface for all
Windows 2008 Server R2 SP1 Standard Edition (64-bit) corporate areas up to the management level.
Windows 7 SP1 (32-bit/64-bit) Professional, Enterprise, Easy handling thanks to the use of standard tools such as
Ultimate MS Word, Excel and PowerPoint
Windows 8.1 Provision of freely configurable reports via Web-based
dashboards
Windows Server 2012 R2
Automatic transmission of reports by e-mail
Windows 10
Import of data from any number of WinCC, WinCC RT
The browsers to be used must have HTML5 capability Professional and PCS7 applications
Internet Explorer as of Version 11.0 Transparent access to WinCC tag and alarm archive and to
Mozilla Firefox (current version) the data of the SIMATIC Process Historian
Google Chrome (current version) Highlights
Office add-ins for Microsoft Excel, PowerPoint and Word, for Set of frequently used report templates for process values,
the following 32-bit Office versions: 2007 SP2, 2010 SP1 and messages and batches
2013 Open reporting system for creating any number of new report
templates
3
SIMATIC Information Server 2014 SP2 has been released for the
following virtual environments: Storage of configured (parameterized) report templates for
VMWare vSphere Hyper Visor (ESXi) V5.5 faster access
Microsoft Hyper-Server 2012 Export of reports in common document formats
Support of subscriptions for cyclic report generation including
e-mail service
Creation and storage of application-specific dashboards
Role management for Windows users; supports workgroups
and Active Directory; user rights can be assigned for specific
projects
Generation of reports and inserting as graphics in Microsoft
Office Word documents
Creation of Microsoft Excel, Word and PowerPoint reports for
historical process values and messages as well as storage of
the Excel report templates on the Information Server
Support of subscriptions for Excel report templates
Mobile access to reports via HTML5-enabled browser, also
from tablets > 10.5

Siemens ST 80 / ST PC 2016 3/103


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
SIMATIC Information Server

Function Ordering data Article No.


Easy creation and individual design of own web pages SIMATIC Information Server 2014 6AV6361-2AA01-4AA0
No web page programming knowledge (html, asp) is SP2 "Basic Package"
necessary Information Server
Information Server -
Creation of meaningful reports with Office knowledge Client access (3)
Easy parameterization of predefined report templates Information Server -
Data source access (1)
Creation of your own report templates based on the Microsoft
Reporting Services as download (for 2014 SP1 only) 6AV6361-2AA01-4AH0
Information Server
High flexibility due to access to numerous WinCC projects and Information Server -
the SIMATIC Process Historian Client access (3)
Information Server -
Use of Microsoft Word and Excel for individual reports Data source access (1)
Consistent configuration of the access protection SIMATIC Information Server
Installation-free in HTML5-enabled browsers on Web client or Client and data source license,
tablet > 10.5" version-independent
1 Client access 6AV6361-2BD00-0AD0
3 3 Client access
5 Client access
6AV6361-2BE00-0AD0
6AV6361-2BF00-0AD0
10 Client access 6AV6361-2BG00-0AD0
1 Data source access 6AV6361-2CD00-0AD0
3 Data source access 6AV6361-2CE00-0AD0
as download
1 Client access 6AV6361-2BD00-0AJ0
3 Client access 6AV6361-2BE00-0AJ0
5 Client access 6AV6361-2BF00-0AJ0
10 Client access 6AV6361-2BG00-0AJ0
1 Data source access 6AV6361-2CD00-0AJ0
3 Data source access 6AV6361-2CE00-0AJ0
Upgrade
Upgrade Information Server 2013 6AV6361-2AA01-4AE0
to Information Server 2014 SP2
as download
Upgrade Information Server 2013 6AV6361-2AA01-4AK0
to Information Server 2014 SP1

3/104 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
SIMATIC Process Historian

Overview

Microsoft Office
Dashboard WinCC (Excel/ Word / Powerpoint)
Dashboard PCS 7 SIMATIC SIMATIC
Information Information
SIMATIC
Server Server
Information
Server SIMATIC
Process Historian

WinCC reports

3
WinCC V7
PCS 7 systems
systems

G_ST80_XX_00604
WinCC RT
Professional
systems

The Process Historian is a powerful, long-term-archive server SIMATIC Process Historian 2014 SP2
solution that stores the WinCC process values and messages in Central, plant-wide long-term archive as corporate information
a central database. The system offers full scalability for perfor- hub
mance and scope. It records and stores data from one or more
WinCC, WinCC RT Professional and PCS 7 projects. The number Real-time archiving of process values and messages from:
of connected single stations, servers, or redundant server pairs - WinCC V7.0 SP3, V7.2, V7.3, V7.4
is unrestricted. SIMATIC Process Historian is designed for use - Data migration, WinCC V 6.2 SP 3 and higher
throughout your plant, and is positioned below the corporate - WinCC/Performance Monitor V7.3 or V7.4
management level (ERP, MES). - WinCC RT Professional, V13 SP1 and higher
- PCS7 V8.0, V8.1
The SIMATIC Information Server is used as a reporting system - SIMATIC BATCH
for the Process Historian. It accesses the central database of the High performance with very large data volumes
Process Historian and visualizes the data in clear, user-friendly
displays on WinCC stations or office PCs. The central Process Data access via OPC UA Server
Historian database provides access to real-time data throughout Migration support for data migration from
the plant. This data is the key to sustainable plant optimization WinCC/ Storage plus, CAS Storage plus and
measures. Since the archive system can be fully integrated, no WinCC segments.
additional engineering is required. SIMATIC Process Historian High availability thanks to redundancy concept with
uses the integrated relational database, SQL Server from observer/witness server for increasing data integrity
Microsoft. No complex reconfiguration is needed because the
archive system is integrated into WinCC. Selected WinCC pro- High degree of security due to integrated, complete backup
cess values or messages are archived long-term on a time or and restore of all segments (disaster recovery)
event-driven basis. Enhanced data security through store and forward
The Process Historian is used for the long-term archiving of mechanism
process values and messages. Scalable without breaks in production
Maximum data transparency
High degree of security thanks to integrated backup system
Simple and fast management and diagnostics with the
Process Historian Management "Dashboard"
Backup & Restore for PCS 7 Batch

Siemens ST 80 / ST PC 2016 3/105


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
SIMATIC Process Historian

Overview (continued) Ordering data Article No.


Operating systems, virtualization
SIMATIC Process Historian 2014
Windows Server 2012 R2 (64-bit Standard / Enterprise) SP2
Windows Server 2008 R2 SP1 (64-bit Standard / Enterprise) Single License 6AV6361-1AA01-4AA0
Single License 6AV6361-1BA01-4AA0
MS SQL Server 2014 SP1 (Redundancy Complete)
2 x Process Historian Server
Process Historian 2014 has been released for the following vir- 2 x Process Historian Server
tual environments: Redundancy
VMWare vSphere Hyper Visor (ESXi) V5.5 Single License Redundancy 6AV6361-1CA00-0AD0
Microsoft Hyper-V Server 2012 as download (for 2014 SP1 only)
Single License 6AV6361-1AA01-4AH0

Benefits Single License


(Redundancy Complete)
6AV6361-1BA01-4AH0

Fully integrated archiving solution for large volumes of data 2 x Process Historian Server
2 x Process Historian Server
Central, plant-wide long-term archive as corporate information Redundancy
hub Single License Redundancy 6AV6361-1CA00-0AJ0

3 Process data and messages from any number of subordinate


WinCC systems can be archived
Process Historian OPC UA Server 6AV6361-1HA01-4AB0
Upgrades
Plant expansions can be implemented without interrupting the Upgrade from CAS (Central 6AV6361-1AA01-4AE0
production process Archive Server) V7.0 SP3 or
High availability in redundant mode Process Historian 2013 to
Process Historian 2014 SP2
High degree of security due to integrated backup system
as download
Database for analyses with the aim of optimizing the plant and
Process Historian OPC UA Server 6AV6361-1HA01-4AJ0
thereby raising productivity
Upgrades
Function Upgrade from CAS (Central
Archive Server) V7.0 SP3 or
6AV6361-1AA01-4AK0

Real-time storage of the WinCC archive data (process values Process Historian 2013 to
and messages) from any number of WinCC stations Process Historian 2014 SP1
Upgrade from CAS V6.2 to V7.0 6AV6371-1DQ17-0XX3
Visualization of the archive data on WinCC clients or WinCC SP3
single stations either directly or using the SIMATIC Information Upgrade from CAS V6.2 ASIA to 6AV6371-1DQ17-0XV3
Server. Process Historian configuration tool for quick and easy V7.0 SP3 ASIA
engineering
The redundant Process Historian is based on Microsoft SQL
Server Mirroring (3rd system for monitoring redundancy avail-
ability)
High degree of security due to integrated complete backup
and restore of all segments
During the initial configuration the database and the segmen-
tation are set up.
The PH-Ready component is installed on the WinCC server for
the process of archiving to the PH
The PH automatically detects all connected WinCC server
projects (via the PH-Ready component)
The Process Historian Management "Dashboard" enables
simple and fast management and diagnostics

3/106 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Calendar Scheduler

Overview Function
With the WinCC Calendar Scheduler, events and their associ-
ated actions can be configured in a user-friendly and clear way
in an editor in WinCC Explorer.
The events are represented in a calendar. The period repre-
sented can be freely selected. Recurring events can be defined
as serial events with any desired exceptions.
The events are displayed in a .Net control. The Calendar
Scheduler is easy and intuitive to operate and supports
drag & drop during configuration and runtime.

Ordering data Article No.

WinCC/Calendar Scheduler
WinCC V7.4 6AV6372-1DC07-4AX0
WinCC V7.3 6AV6372-1DC07-3AX0
as download
WinCC V7.4 6AV6372-1HC07-4AX0
3
WinCC V7.3 6AV6372-1HC07-3AX0
V7.x -> V7.4 6AV6372-1KC07-4AX3
V7.0/7.2 -> V7.3 6AV6372-1KC07-3AX3
Option for SIMATIC WinCC for managing events in a calendar. Upgrade
Setting WinCC variables or starting global scripts at defined V7.x -> V7.4 6AV6372-1DC07-4AX3
times. V7.0/7.2->V7.3 6AV6372-1DC07-3AX3
A license is only necessary on the server (or single user
system).

Benefits
Simple operation, configuration and planning of events thanks
to handling in the style of Microsoft Office Calendar
Simple configuration of the actions by parameterization
(execution of WinCC scripts or writing of WinCC tags at certain
times)
Configuration of recurring events taking account of configu-
rable public holidays, vacation periods, and maintenance
periods
Secure operation of the plant taking account of different
authentication levels
Clear representation of events at runtime by means of
Calendar Runtime Control
Flexible use in all typical WinCC plant configurations,
client/server, redundant systems, WebNavigator

Siemens ST 80 / ST PC 2016 3/107


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit

Overview Benefits
Quick and easy traceability configuration
Gap-free and automated recording of engineering changes
and operator actions in an audit trail
Reduction in plant downtimes thanks to fast analysis of the
gap-free recorded audit trail information
Logging of defined WinCC project status with all database
information and files of the application
Gap-free documentation of the project version definition
procedures with version number, user and comments
Complete tracing support by WinCC single and multi-station
systems, single and multi-project solutions, Client/Server
architecture
Extensive reduction in engineering outlay in order to meet the
requirements of FDA 21 CFR Part11 & EU 178/2002

3 WinCC/ChangeControl is used to trace engineering


changes in a tamper-proof long-term audit trail database,
Compliance with the requirements of the Food and Drug
Administration (FDA) for the food, beverages and tobacco
called the audit trail for short. All changes are automatically industries
entered in the engineering system in the audit trail. This
enables all the changes to be traced that have been made, to
deduce the causes and minimize downtimes on the system.
Design
To begin tracing at a defined project status, a project version WinCC/ChangeControl and WinCC/Audit consist of
definition is provided that contains all data and files of a five components:
WinCC project version. The project version definition naturally The audit editor for configuration the audit trail content
provides the ability to reactivate earlier project versions.
Document management is also provided, which manages and The project version definition for logging WinCC projects
archives intermediate status for system graphics, reports or Document management for automatic archiving and
user files and stores change information of the user. An audit versioning of WinCC plant mimics, scripts, reports, and
viewer with helpful filter functions can be used for quickly and project-specific documents, and the recording of the
simply evaluating the audit trail, exporting it to an Excel sheet associated change information
or printing it out. The audit viewer for visualizing, exporting and printing WinCC
WinCC/Audit Includes the full functionality of and WinCC flexible audit trails. The viewer is available as an
WinCC/ChangeControl and is also used for tracing all executable program under Windows, as well as OCX with
operations. All operations are automatically recorded in the WinCC Runtime.
audit trail at RT. The audit trail, which tracks all changes in respect of both
Licensing: To configure which change information from the engineering and plant operation in a separate SQL database.
project should be recorded in the audit trail, the The audit trail can be set up as a central audit trail for a
WinCC/ChangeControl RC or WinCC/Audit RC package is number of projects or even just for a single project.
required. "RC" stands for Runtime and Configuration. It is
required on the station that is to be configured and also WinCC/ChangeControl and WinCC/Audit support both single-
includes an RT license. For recording an audit trail, one user and multi-user systems, client/server architectures and
WinCC/Audit RT license is required per WinCC station even the WinCC redundancy system. No redundant audit trail is
(Client/Server). created however.
The options WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon support users in the validation of his/her plant
and meet the requirements of FDA CFR 21 Part 11. This can
be looked up in the declaration of conformity (White Paper).

3/108 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit

Function Ordering data Article No.

WinCC/ChangeControl WinCC/ChangeControl
For the configuration of the audit
WinCC/ChangeControl is a functional subset of WinCC/Audit. trail incl. RT
WinCC/ChangeControl is for tracing engineering changes in the WinCC V7.4 6AV6371-1DV27-4AX0
engineering phase or in online operation. All change data is WinCC V7.3 6AV6371-1DV27-3AX0
recorded in an audit trail.
as download
There are two types of engineering changes: WinCC V7.4 6AV6371-1HV27-4AX0
those that change the WinCC database or are executed WinCC V7.3 6AV6371-1HV27-3AX0
through the WinCC Explorer, such as e.g. changes to tag WinCC/Audit RC
management or creating a user group,
For the configuration of the audit
and those trail incl. RT
WinCC V7.4 6AV6371-1DV17-4AX0
limited to changing files, the so-called document
administration. WinCC V7.3 6AV6371-1DV17-3AX0
as download
The document management manages system images, scripts WinCC V7.4 6AV6371-1HV17-4AX0
and log layouts and customer-specific documents and stores
respective intermediate versions as backups. All of these docu-
WinCC V7.3
WinCC/Audit RT
6AV6371-1HV17-3AX0
3
ments or files are subject to a change process, i.e. documents
can be booked out for processing, booked in for finalization and Creation of audit trails in RT
intermediate versions can be retrieved from backup storage with WinCC V7.4 6AV6371-1DV07-4AX0
a rollback function. WinCC V7.3 6AV6371-1DV07-3AX0
The project version definition as a component of as download
WinCC/ChangeControl archives WinCC projects and creates WinCC V7.4 6AV6371-1HV07-4AX0
reproducible project status or defined start-time points for WinCC V7.3 6AV6371-1HV07-3AX0
starting tracing. An audit trail is also provided with information on Upgrades
who has created which project version or which version has
been reproduced or deleted. V7.x to V7.4
for WinCC/Audit RT 6AV6371-1DV07-4BX3
Configuring the audit trail, the project version definition and the for WinCC/Audit RC or 6AV6371-1DV17-4BX3
document management is simple, quick and comfortable. WinCC/ChangeControl
The audit trail data is visualized from WinCC, as well as from as download
WinCC flexible via the audit viewer, an executable program WinCC/Audit RT 6AV6371-1KV07-4BX3
under Windows. The data can also be evaluated with the audit for WinCC/Audit RC or 6AV6371-1KV17-4BX3
viewer OCX in Runtime by WinCC however. Users select the WinCC/ChangeControl
desired view of the audit trail information via filters or selection V7.x to V7.3
criteria and can export the data to an Excel file or print it on a for WinCC/Audit RT 6AV6371-1DV07-3BX3
printer. Audit trail information is tamper-proof and can thus not for WinCC/Audit RC or 6AV6371-1DV17-3BX3
be modified or deleted. An export function can be used to swap WinCC/ChangeControl
out the audit trail to an XML file or to archive it. as download
WinCC/Audit RT 6AV6371-1KV07-3BX3
WinCC/Audit
For WinCC/Audit RC or 6AV6371-1KV17-3BX3
WinCC/Audit has all of the functionality of WinCC/ChangeControl WinCC/ChangeControl
and is also used for tracing user operations in RT operation. V6.x to V7.3
Tracing can be used for determining who, when and what con- for WinCC/Audit RT 6AV6371-1DV07-3BX4
ditions the machine has undergone. In addition to recording op- for WinCC/Audit RC or 6AV6371-1DV17-3BX4
erator activities, the audit trail also records the starting and mod- WinCC/ChangeControl
ifying of recipes or user logs. At specific objects or events, such as download
as function buttons or sliders, the user can also record activities WinCC/Audit RT 6AV6371-1KV07-3BX4
of an individual nature such as e.g., pressing a function button,
For WinCC/Audit RC or 6AV6371-1KV17-3BX4
moving sliders and other actions with a so-called audit entry WinCC/ChangeControl
function in the audit trail.
WinCC/Audit is not released for virtualization and redundancy.
A WinCC/ChangeControl RC license or a WinCC/Audit RC
license is required for configuring the audit trail. One RT license
is required for each station (client/server) to be monitored. One More information
RC license always includes one RT license.
Information about FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC to
FDA21 CFR Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm

Siemens ST 80 / ST PC 2016 3/109


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Connectivity Pack & WinCC Connectivity Station

Overview

VB (.NET), C#
MES ERP MES
VBScript, VBA

Online data access Online messages Online data access Access to database through
(to tags) (Forward / Acknowledge) (to historical data) 3rd party application

* * *

OPC UA Server (DA, A&E, HDA)

OPC A&E
OPC UA DA OPC XML DA OPC A&E (historical) OPC HAD WinCC OLE DB
3 (client) (server/client) (server) (server) (server)

WinCC/ConnectivityPack

G_ST80_XX_00066
SIMATIC WinCC MS SQL Server

* 3rd party OPC client is required

Cross-vendor communication in the automation sector has The Connectivity Pack includes OPC XML DA 1.00,
always been of primary importance for WinCC. This is even more OPC HDA 1.20 (Historical Data Access), OPC A&E 1.10
true for the release of preprocessed production data for higher- (Alarm & Events) as well as a WinCC OLE-DB interface, which
level information systems (e.g., MES = Management Execution also gives remote computers without installed WinCC access
System, ERP = Enterprise Resource Planning or Office to WinCC archive and alarm data.
packages = MS Excel, MS Access etc.). WinCC features The function of the OPC servers (XML DA, HDA and A&E) and
integrated OPC Data Access and OPC XML DA servers for the OPC UA servers (DA, HDA, AC) is assured by the
access to all online values in the system and makes open WinCC/Connectivity Pack. In order to access data in the
interfaces available for access to historical WinCC data. database via WinCC OLE-DB/OLE-DB, you will also need a
license for the WinCC/Connectivity Pack.
A Connectivity Pack license is required for every
WinCC system to be accessed.
If the Connectivity Station is used, an additional Connectivity
Pack license does not have to be installed on the WinCC
systems that are accessed. The Connectivity Station functions
autonomously and does not require a WinCC installation on
the computer.

3/110 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Connectivity Pack & WinCC Connectivity Station

Benefits OPC interfaces of the Connectivity Station


The Connectivity Station provides interfaces via which you can
Access to variables, historical WinCC data, alarm data and
access the following using an OPC-Client.
user archives from any computer
OPC-DA-Server: tags, e.g. process values
Options for analyzing and evaluating process data with
specialist tools or user-defined applications OPC-HDA-Server: archived process values
(e.g., via VisualBasic) OPC-A&E-Server: alarms

Function Licensing
You require the "WinCC Connectivity Station" license in order
As an OPC HDA server, WinCC makes historical data from the to utilize the OPC interfaces of the Connectivity Station on a
WinCC archive system available to other applications. computer without WinCC installed.
An OPC HDA client (e.g. a reporting tool) can define the time
interval for the required data by entering a start and end time. If you only use the OPC interfaces of a WinCC installation,
OPC HDA servers also support the generation of a variety of you only need the "Connectivity Pack" license.
aggregate functions on the server itself (e.g. standard deviation, The following table shows the combinations:
variance, mean values, integral values, etc.), thereby helping to
relieve the load on the network, as only preprocessed data are New: WinCC-independent Standard installation:
transmitted.
OPC A&E servers are used to forward WinCC messages (along
installation with
Connectivity Station
OPC with WinCC
3
OPC DA "WinCC Connectivity Station" No license required
with all associated process values) to any client at production or license
enterprise control level. Filter mechanisms and subscriptions en-
sure that only selected modified data are transmitted. Acknowl- OPC HDA "WinCC Connectivity Station" "WinCC Connectivity Pack"
license license
edgement is of course also supported.
OPC A&E "WinCC Connectivity Station" "WinCC Connectivity Pack"
The WinCC OPC XML DA server makes cross-platform commu- license license
nication between Windows and non-Windows systems possible,
OPC UA DA "WinCC OPC UA HDA / AC
even via the Internet. This enables read and write WinCC online Connectivity Pack" license
values (external and internal WinCC variables) to be exchanged
with non-Siemens systems. The Connectivity Station is planned over NCM PC Manager or
SIMATIC Manager. In the versions 7.0 and higher, the
WinCC OLE-DB makes standardized and user-friendly access to
Connectivity Station does not run as a service.
WinCC archive data possible (MS SQL Server 2005). In exactly
the same way as access via the OPC HDA and OPC A&E inter-
faces, access via the WinCC OLE DB provider makes all WinCC Ordering data Article No.
archive data available along with the associated process values
and message/user texts. The WinCC OLE-DB provider also sup- WinCC/Connectivity Pack &
ports analysis functions such as minimum, maximum, message WinCC/Connectivity Station
hit list, etc. V7.4; for WinCC V7.4

The WinCC Connectivity Station was designed as a stand-alone Basic packages


gateway to WinCC server data. It supports access to WinCC/Connectivity Pack V7.41) 6AV6371-1DR07-4AX0
WinCC server data over the OPC channels described as well as WinCC/Connectivity Station V7.41) 6AV6371-1DR17-4AX0
those for process values (not alarms) over OLE DB . Access to as download
WinCC data is transparent, i.e. independent of which server of a WinCC/Connectivity Pack V7.4 6AV6371-1HR07-4AX0
redundant pair is active or whether data have already been WinCC/Connectivity Station V7.4 6AV6371-1HR17-4AX0
transferred to the central archive server.
V7.3; for WinCC V7.3
Connectivity Station Basic packages
If no visualization is required at a station, any Windows computer WinCC/Connectivity Pack V7.3 1) 6AV6371-1DR07-3AX0
with access to WinCC via OPC and OLE-DB can be configured WinCC/Connectivity Station V7.3 1) 6AV6371-1DR17-3AX0
via the Connectivity Station. This permits access to WinCC as download
stations with server packages from a central computer without WinCC/Connectivity Pack V7.3 6AV6371-1HR07-3AX0
WinCC installation. The WinCC stations can be accessed via the WinCC/Connectivity Station V7.3 6AV6371-1HR17-3AX0
following interfaces: 1)
Upgrades to V7.x are included in the WinCC V7.x basic software
OPC interfaces of the Connectivity Station upgrades.
OLE DB interface of the Connectivity Pack
The two access variants are autonomous access options with
different ranges of functions.

Siemens ST 80 / ST PC 2016 3/111


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/DataMonitor

Overview
Dashboard SIMATIC
WinCC Information Server

Internet
WinCC WinCC SCADA client
SCADA clients + SIMATIC Information Server Dashboard
or DataMonitor server WinCC

3 LAN

WinCC server
(18 max.)

PROFINET

PROFIBUS

G_ST80_XX_00021
S7-300

S7-1500
S7-400

The WinCC/DataMonitor is a component of WinCC Plant DataMonitor does not require manual client installation
Intelligence and is used for displaying and evaluating current because it loads the required components from the
process statuses and historical data on office PCs with DataMonitor server
standard tools such as Microsoft Internet Explorer or Microsoft There is no installation required on the client for the
Excel. The DataMonitor client is provided with current and Webcenter, Trends and Alarms functions.
historic process data and alarms by a DataMonitor server. All
staff ranging from machine operators to corporate managers Licenses for simultaneous access by 1, 3, 10, 25 or 50
can use the DataMonitor to obtain information. DataMonitor clients. Any combination of DataMonitor and
WebNavigator licenses can be used for an application.
DataMonitor is a suite of Internet-capable tools:
- Process Screens - Tool for simple visualization and Preconfigured Web Center pages permit ad hoc entry
navigation with WinCC screens using WinCC Web Viewer
(WinCC Viewer RT) in "view only" mode
- Excel Workbooks - Protocol tool that integrates
WinCC archives and online values into MS Excel and
supports online analysis
- Published Reports - Event- or time-driven execution of Excel
or PDF reports for the output of process data and analysis
results
- WebCenter - Individual configuration of Internet pages and
compilation of information within a portal related to WinCC
applications.
- Trends and alarms are preconfigured Web Center pages

3/112 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/DataMonitor

Benefits
Information can be compiled online individually during New in DataMonitor
runtime via the Internet/intranet. Excel Workbook Wizard
Efficiently monitor and analyze production lines. - Settings for the properties can be saved in templates
- Display and evaluation of current process states and - For the display of messages, the time span can be
historical data on remote office PCs with standard tools such configured in a relative or absolute time format.
as Microsoft Internet Explorer or Excel. - Log File for logging events which have arisen during
- Easy access to production data via the intranet or Internet reporting.
- Quick ascertainment of the production situation WebCenter
- Use of standard products - Language-specific display of static process images in the
Easily collect and distribute information. WebCenter
- Automated report creation - Execution of time-triggered reports
- No additional configuration effort through direct use of - Configuring of different start times for reporting.
images from the WinCC project The starting and ending times can be before the report
- No training required for standard products creation time. For example, a report is created at 5 PM which
- Easy exchange of configuration data contains values for the time between 8 AM and 4 PM.

3
Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics)
- Make bottlenecks transparent
- Individual views for user and situation
- Relative and absolute timeframe for information generation
View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights
Access to the lower-level servers when installing the
DataMonitor server on a WinCC Client with separate project
(RT128 license)
Tag logging archive tags can be accessed by means of the
web center function without changing the WinCC configu-
ration system.
Installation of the DataMonitor web center function on a
WinCC file server
Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools which
can be integrated in the Internet sites are available.
- Bar diagram, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports
- Links to internal and external pages
- Display of graphics in converted jpg format
- Display of the WinCC process images
The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
Reports generated with Excel or the WinCC Report Designer
can be made available on the DataMonitor server or emailed
automatically to the relevant group of people based on time
intervals or triggered by events.
- Connections can be established to WinCC Runtime, the
central archive server, and the swapped-out archives.

Siemens ST 80 / ST PC 2016 3/113


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/DataMonitor

Function Ordering data Article No.


All tools are fully Internet-compatible and, therefore, support WinCC/DataMonitor V7.4 for
access via any type of connection (LAN, GSM, radio, modem, WinCC V7.4 and WinCC V7.4
Internet, etc.). ASIA
All popular security mechanisms such as login/password, 1 client license (countable) 6AV6362-3AB00-0BB0
firewalls, encryption, etc. are supported. 3 client licenses (countable) 6AV6362-3AD00-0BB0
10 client licenses (countable) 6AV6362-3AF00-0BB0
Users can combine the available tools at will. Licensing only
30 client licenses (countable) 6AV6362-3AJ00-0BB0
takes into account simultaneous access to one Web server.
as download
For display purposes, screens from the WinCC project can be
1 client license (countable) 6AV6362-3AB00-0AH0
used or special overview displays configured. Animations,
3 client licenses (countable) 6AV6362-3AD00-0AH0
scripts, navigation and access rights remain valid.
10 client licenses (countable) 6AV6362-3AF00-0AH0
The WinCC/DataMonitor has purely a display function. 30 client licenses (countable) 6AV6362-3AJ00-0AH0
Company-wide Excel reports, which contain historical and WinCC/DataMonitor V7.3 for
current process values, can be stored centrally for general WinCC V7.3 and WinCC V7.3
access (reports, statistics). However, local queries to meet ASIA
individual requirements can be compiled and executed 1 client license 6AV6371-1DN07-3LX0
3 online. Plot and tabular representation are supported for
archive data already swapped out.
3 client licenses
10 client licenses
6AV6371-1DN07-3AX0
6AV6371-1DN07-3BX0
Data can be automatically entered into created report 25 client licenses 6AV6371-1DN07-3CX0
templates and distributed by e-mail or saved on the server. 50 client licenses 6AV6371-1DN07-3DX0

Pre-made elements make the assembly of individual web as download


pages easier for evaluating information. 1 client license 6AV6371-1HN07-3LX0
3 client licenses 6AV6371-1HN07-3AX0
Individual information compilation on one or more Internet 10 client licenses 6AV6371-1HN07-3BX0
pages with the option of branching to other detail pages. 25 client licenses 6AV6371-1HN07-3CX0
Pre-made Internet pages for trend and alarm display enable 50 client licenses 6AV6371-1HN07-3DX0
an ad-hoc entry to Internet data evaluation.
WinCC/DataMonitor Powerpacks
An higher-level navigation feature provides a common V7.3
framework for the various tools. From 1 to 3 clients 6AV6371-1DN07-3LA0
The screens are displayed in the WinCC Web Viewer or in the From 3 to 10 clients 6AV6371-1DN07-3AB0
Internet Explorer in the view only mode of the WebNavigator. From 10 to 25 clients 6AV6371-1DN07-3BC0
From 25 to 50 clients 6AV6371-1DN07-3CD0
Enhanced user management for the web center in order to
assign individual Internet pages and created reports to as download
specific user groups. From 1 to 3 clients 6AV6371-1JN07-3LA0
From 3 to 10 clients 6AV6371-1JN07-3AB0
Integrating WinCC process screens on Internet pages without From 10 to 12 clients 6AV6371-1JN07-3BC0
installation download From 25 to 50 clients 6AV6371-1JN07-3CD0
A search function facilitates the management of connections
to the WinCC Server.
Swapped out archives can be connected and evaluated in the
DataMonitor Web center. Expansion of the display area in the
Web center (Menu Hide function)
Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.

3/114 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Event Notifier

Overview Function
The WinCC Event Notifier enables the following to be configured
in a clear and user-friendly manner via the Calendar Options
Editor in the WinCC Explorer:
The e-mail service for sending and receiving messages
The messages by selecting configured messages in the
WinCC Alarm System as well the setup and contents of the
message by selecting the message blocks
Contacts by selecting predefined persons from the WinCC
user administration.
In a calendar it is then possible to select the persons to be noti-
fied within in the opened time slot from the existing contacts. If
several persons or groups of persons are set up for the same
time slot, escalation levels can be implemented by assigning dif-
ferent escalation times (= dead time before notification). The pe-
riod represented by the calendar can be freely selected. Recur-
ring events can be defined as serial events with any desired
exceptions.
3
The calendar can also be integrated as .Net Control in WinCC
screens; the appearance of the calendar controls at runtime is
configurable. Via the calendar control, you can create time slots
Option for SIMATIC WinCC for notifying selected persons by during runtime with contacts who should be notified upon occur-
email in specified time slots. rence of the configured events in the WinCC Alarm System. In
Notification depends on events occurring in the WinCC Alarm addition, the calendar control allows the creation of new con-
System. tacts by means of selection from the WinCC user management.
Escalation levels, i.e. Group 2 is only notified when nobody "on The Event Notifier is easy and intuitive to operate and supports
site" or from Group 1 has reacted within a specified time. drag & drop during configuration and runtime.
Final notification of all persons previously notified in
connection with the specific event about the reaction that has
taken place
Ordering data Article No.

WinCC/Event Notifier
A license is only necessary on the server (or single user system).
for WinCC V7.4 6AV6372-1DD07-4AX0

Benefits
for WinCC V7.3 SE 6AV6372-1DD07-3AX0
as download
Simple operation, configuration and planning of notifications for WinCC V7.4 6AV6372-1HD07-4AX0
thanks to handling like the Microsoft Office Calendar for WinCC V7.3 SE 6AV6372-1HD07-3AX0
Easy configuration of the notifications including support of the
WinCC Runtime languages by connecting to the WinCC alarm
system
Configuration of recurring events taking account of configu-
rable public holidays, vacation periods, and maintenance
periods
Secure operation of the plant taking account of different
authentication levels
Clear display and intuitive operation at runtime by means of
Calendar Control
Flexible use in all typical WinCC plant configurations, single
station, client/server, redundant systems, WebNavigator

Siemens ST 80 / ST PC 2016 3/115


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/IndustrialDataBridge

Overview

Microsoft Excel
SIMATIC NET OPC Server Microsoft SQL Server Oracle
File (CSV)
OPC DA & OPC XML DA Microsoft Access My SQL Server
Free Text

online online online online


data exchange data exchange data exchange data storage

3 SIMATIC WinCC - IndustrialDataBridge

G_ST80_XX_00067
Microsoft SQL Server
SIMATIC WinCC WinCC OLE DB database
WinCC RT Professional Send & Receive
User Archive (Alarm, Tag Logging)

The WinCC/IndustrialDataBridge option uses standard inter- For example, SIMATIC WinCC with its OPC DA server
faces in order to connect the automation world with the world interface is the data source and an external database is the
of IT and ensure two-way information flow. Typical examples of data destination.
such interfaces are OPC in the field of automation and SQL - Very flexible, due to the support of different database
database interfaces in the world of IT. formats and standard interfaces
Using the SIMATIC WinCC/IndustrialDataBridge, communi- - Fast and safe due to configuration instead of programming
cation links between different data sources and data targets In addition to access to WinCC variables, access to
can be created by means of simple configuration/ messages, process values and user archive data (in the
programming. The IndustrialDataBridge can either be WinCC database) is also supported.
integrated into WinCC or used in stand-alone mode (not in WinCC/IndustrialDataBridge can be used as a standalone
conjunction with WinCC) application with its standard interfaces.

3/116 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/IndustrialDataBridge

Benefits
Connection of the automation level to the IT world Highlights
Integration of systems from different manufacturers via No programming knowledge required
numerous standard interfaces (including OPC, OLE-DB, office Efficient due to transmission of individual data or block
formats, etc.) transfer (">", "<", "inside where)
Simple configuration using standard software without Unicode support
programming which reduces costs
Support of Asian languages (Simplified Chinese, Japanese)
High-performance data exchange between several systems
at the same time OPC XML DA Provider / Consumer (data exchange over the
Internet using http and SOAP)
WebNavigator; support of the IndustrialDataBridge controls in
WinCC images
IndustrialDataBridge runs as system service or as an
application in connection with WinCC or as a standalone
application

Design 3
The software comprises a configuration environment and a run- The connections between data source and data destination are
time environment. The different data interfaces are integrated via created in the configuration environment. In the runtime environ-
software modules. In each case, one module is required as the ment, the IndustrialDataBridge establishes the connection au-
data source and one module as the data destination. The differ- tonomously and transfers the data of the linked variables.
ent modules can be combined in any way.

Function
Storage of process data in Office formats such as Excel or
Access. Databases can also be integrated for the archiving of
larger aggregates.
One of the features of IndustrialDataBridge is a Send/Receive
interface supporting data transfer to SIMATIC S5/S7 stations
or other Send/Receive-compatible devices.
IndustrialDataBridge enables SCADA and control systems
from different vendors to be linked via the OPC interface.
Communication via RFC1006 or Send/Receive is also
supported.
SQL databases are available as data destinations for
production data acquisition. Data can be transferred from the
data source on an event-driven basis with the OPC module or
sent directly from the PLC with the Send/Receive module.
Cyclic data archiving can be implemented via the OPC Data
Access, WinAC ODK or Send/Receive data sources and the
SQL database data destinations. On the database side,
various transmission mechanisms are supported. Individual
control during the runtime for every Industrial Databridge
connection (Start, Stop, Connect and Disconnect).
IndustrialDataBridge establishes a link between the source
Integration of the IndustrialDatabridge runtime control into
and destination interfaces and transfers data on the basis of a
WinCC screens when installing the IDB on a WinCC station.
change in value, once a configurable period of time has
elapsed or when a specific event occurs. Independent CSV files are created on reaching a program-
mable number of entries or if the value of a WinCC tag
IndustrialDataBridge exchanges data between automation
changes.
systems from different vendors, e.g., via OPC. The connection
of OPC servers via IndustrialDataBridge enables communi- Block transfer for databases through the support of the
cation between a variety of devices, data sources and data operators "<" and ">" in the Select instruction.
destinations. The OPC international interface standard is the Available providers (data sources) can be connected to any
key to open systems both now and in the future. Thanks to consumers (data targets) (see Table below)
IndustrialDataBridge, OPC data exchange can already be
supported.
WinCC supports access to tags, tag logging, alarm logging
and user archive data.

Siemens ST 80 / ST PC 2016 3/117


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/IndustrialDataBridge

Function (continued) Ordering data Article No.


New functions in Version 7.4
WinCC/IndustrialDataBridge
Functions for configuration: V7.4, option for WinCC 7.4
Graphic design of links via drag-and-drop For data exchange with databases
and OPC servers;
Import and export of links language versions: English,
Highlighting of selected links German, Simplified Chinese,
Japanese
Renaming of links at any time Basic package 6AV6362-4AA07-4AA0
Fast switch to graphic link configuration With 300 tags (countable) 6AV6362-4AD00-0BB0
With 1 000 tags (countable) 6AV6362-4AF00-0BB0
Functions for extended connection: With 3 000 tags (countable) 6AV6362-4AH00-0BB0
Freely editable text and XML Consumer (for writing tag values
as download
in an SAP iDoc file, for example)
Basic package 6AV6362-4AA07-4AH0
Support for updated provider/consumer data providers: With 300 tags (countable) 6AV6362-4AD00-0AH0
MySQL 5.7, MS SQL Server 2014, Microsoft Access 2013, With 1 000 tags (countable) 6AV6362-4AF00-0AH0
Oracle 12c (latest patch) With 3 000 tags (countable) 6AV6362-4AH00-0AH0
3 Licensing: V7.3, option for WinCC 7.3 SE
New flexible license model For data exchange with databases
and OPC servers;
(300 tags + 1000 tags = 1 300 tags) language versions: English,
German, Simplified Chinese,
New functions in Version 7.3 Japanese
Copy & Paste in the project navigation With 128 tags 6AV6371-1DX07-3AX0
Adding of new links in the project navigation With 512 tags 6AV6371-1DX07-3BX0
With 2 048 tags 6AV6371-1DX07-3CX0
Creation of new lines in the CSV consumer With 10 000 tags 6AV6371-1DX07-3DX0
WinCC Professional V13 SP1 (via OLE DB provider and as download
consumer) With 128 tags 6AV6371-1HX07-3AX0
Freely-editable text and HTML consumer With 512 tags 6AV6371-1HX07-3BX0
Provider data can be inserted at any text positions of the With 2 048 tags 6AV6371-1HX07-3CX0
consumer. With 10 000 tags 6AV6371-1HX07-3DX0
Therefore optional TXT or HTML pages can be produced for
WinCC/IndustrialDataBridge V7.3
archiving or visualization via HTML pages. Powerpack
The IndustrialDatabridge can be controlled over the Internet in From 128 to 512 tags 6AV6371-1DX07-3AB0
combination with the WebNavigator Server. From 512 to 2 048 tags 6AV6371-1DX07-3BC0
From 2 048 to 10 000 tags 6AV6371-1DX07-3CD0
Interfaces:
as download
The table below shows the possible data sources and From 128 to 512 tags 6AV6371-1JX07-3AB0
destinations From 512 to 2 048 tags 6AV6371-1JX07-3BC0
From 2 048 to 10 000 tags 6AV6371-1JX07-3CD0
Provider (data sources) Consumer (data destinations)
WinCC/IndustrialDataBridge,
csv, txt Upgrade
MS Excel 2003, 2007, 2010, 2013 From V7.x to V7.4 6AV6362-4AA07-4AE0
MS Access 2003, 2007, 2010, 2013 MS Access 2003, 2007, 2010, 2013 From V7.x to V7.3 6AV6371-1DX07-3XX3
From V6.2 to V7.3 6AV6371-1DX07-3XX4
MS SQL Server 2005, 2008, 2008 MS SQL Server 2005, 2008, 2008
R2, 2012 R2, 2012 as download
MySQL 3.5, 5.1, 5.5, 5.6 MySQL 3.5, 5.1, 5.5, 5.6 From V7.x to V7.4 6AV6362-4AA07-4AK0
From V7.x to V7.3 6AV6371-1KX07-3XX3
Oracle 8i, 10g, 11g, 12c release 2 Oracle 8i, 10g, 11g, 12c release 2 From V6.2 to V7.3 6AV6371-1KX07-3XX4
OPC Data Access 3.0, OPC XML 1.0 OPC Data Access 3.0, OPC XML 1.0
IDB OPC Server
Send/Receive Send/Receive
WinCC V7.2, V7.3 (via OLE DB) WinCC UserArchives V7.2, V7.3
WinCC UserArchives V7.2, V7.3
WinCC RT Professional V13 SP1 WinCC RT Professional V13 SP1
(via OLE DB) (via OLE DB)
Configurable TXT/ HTML

3/118 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Open Development Kit (ODK)

Overview Function
WinCC/ODK (Open Development Kit) The API functions are configuration and runtime functions, and
WinCC option for utilization of the exposed programming inter- include:
faces that can be used to access data and functions of the MSRTCreateMsg: Creates a message
WinCC configuration and WinCC runtime system DMGetValue: Gets the value of a variable
The interfaces are designed as "C-Application Programming PDLRTSetProp: Sets the object properties in a display
Interface" (C-API)
They can be used in the following places:
Scope of delivery: CD-ROM with documentation and
examples within WinCC, for example in global scripts or as part of C
actions in the Graphics Designer,
Benefits in Windows applications in the programming language C
(the current version of Microsoft Visual C++ is necessary as a
Individual system expansions via an open standard development environment for WinCC).
programming language
Access to data and functions of the WinCC configuration and
runtime system
Ordering data Article No.

Development of your own applications and add-ons for the


WinCC basic system
SIMATIC WinCC/ODK
Open Development Kit,
3
Option for SIMATIC WinCC
V7.4 6AV6371-1CC07-4AX0
V7.3 SE 6AV6371-1CC07-3AX0
as download
V7.4 6AV6371-1GC07-4AX0
V7.3 SE 6AV6371-1GC07-3AX0

Siemens ST 80 / ST PC 2016 3/119


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/PerformanceMonitor

Overview

SCADA clients SCADA clients

LAN
WinCC server
WinCC SCADA server
SCADA server
+ PerformanceMonitor
(17 max.)

3
PROFINET

PROFIBUS
S7-400 S7-1500 S7-300

G_ST80_XX_00602
WinCC/PerformanceMonitor
Analysis and optimization of production on the basis of
individual performance indicators
The WinCC/PerformanceMonitor facilitates flexible calculation Analysis of the indicators and their operands can be carried out
and powerful analysis of plant-specific key performance indica- in the WinCC system at any time. Indicators, along with their
tors (KPIs). The indicators provide the basis for deriving optimi- associated values if required, can be clearly displayed in bar
zation potential, thus enabling productivity enhancement. graphs, allowing easy comparison. In addition, the input values
of each performance indicator can be shown via an integrated
They relate to individual machine groups, plant sections or analysis function (drill-down). The Gantt chart illustrates the
production lines. The elements to be monitored are designated chronological sequence of the operands. The table display lists
as equipment. Indicators are calculated based on operands the archived values, allowing subsequent correction if required.
which are derived from already configured WinCC tags. By com- Performance indicators calculated online, either cyclically or
bining them with associated values, more accurate production triggered by a tag, can be written to WinCC tags for further
correlations can be highlighted, such as quality/supplier depen- processing, and display in WinCC images, for example.
dencies. The calculation formulas used are quick and simple to
create in WinCC.

3/120 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/PerformanceMonitor

Overview (continued) Servicing and maintenance


Support through cyclic and process-event triggered calculation
The PerformanceMonitor can be combined with the
of characteristics:
WebNavigator for distribution on the internet, and with the
Information Server for reporting purposes. Integration into Standardization of new plants by defining controller-based
WinCC ensures fast configuration and complete transparency status information for key figure calculation
across all machine and plant data as a basis for optimizing plant Individual, targeted analysis using plant-specific performance
productivity. indicators.
The WinCC/PerformanceMonitor can be installed on a WinCC Weak-point analysis in production processes and recording of
stand-alone system, WinCC Server or WinCC client project undesirable process activities.
(RT 128 license), and consists of an engineering client as well
Cause analysis by examining "drill down to operands" calcu-
as a runtime user interface.
lation basis.
The WinCC/PerformanceMonitor provides ActiveX control
Identification of the events that lead to cost-intensive failures.
elements for embedding in WinCC images.
- PerformanceControl: Bar graphs for displaying performance Line management and plant operator
indicators in relation to context values, showing the
operands for cause analysis in each case. The operator is always kept up-to-date by graphical display of
- Gantt chart: Chronological sequence of time-based the characteristics.
operands
- TableControl: Tabular listing of operands with post correction
Later modification of archived input values.
Continuous information at the operator interface thanks to
3
option. integration in the WinCC user interface.
With the help of the integrated configuration environment, Alarm messaging of limit violations and trend recording
operands are calculated (based on tags) which can be used through cyclic calculation of characteristics.
to calculate key statistics at the set evaluation time.
Integration into the WinCC system means it is not necessary
For analysis via intra- or Internet, the controls of the to train operating personnel
WinCC/PerformanceMonitor are available when using the
WinCC/WebNavigators. Quick detection of weaknesses in the process using cyclic
calculation of characteristics.
The SIMATIC Information Server can be used for generating
plant-specific, Web-based reports (predefined, expandable WinCC Engineering
exports). Quick configuration of WinCC operator displays with WinCC
The archived values (operands, context) form the foundation and web-based reports from the Information Server.
for the analysis and are one-by-one licensing relevant on an Minimal networking overhead by using the WinCC infra-
additive basis. structure in the local network as well as for the Internet.
The basic package comprises a configuration environment, Short familiarization times and simple configuration using
runtime controls (bars, Gantt, tables) and a license for familiar tools for user interfaces and reports (WinCC, SIMATIC
archiving 30 values. The logged values (operands, context) Information Server)
form the basis of the analysis.
Minimal configuration overhead due to the type-instance
If more values are to be archived, the number of archive concept
values can be increased in steps of 30, 100, 300 or 1 000.
Minimal administrative overhead by using the WinCC infra-
structure in the local network as well as for the Internet.
Benefits Highlights
Management and quality assurance
Creation of performance indicators by the WinCC engineer with
Complete transparency throughout the machine park as the subsequent utilization by all user groups in the manufacturing
basis for optimizing plant productivity. company on WinCC stations or Internet clients.
Recording of downtimes, localizing causes and reasons for
failure times, and monitoring of equipment efficiency.
Decision making based on performance indicators.
Global availability of information server reports means they
can be used by different user groups.
Recognition of production correlations by combining
associated values with indicators such as material used.

Siemens ST 80 / ST PC 2016 3/121


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/PerformanceMonitor

Application Ordering data Article No.

All user groups benefit from the PerformanceMonitor, from the WinCC/PerformanceMonitor
application engineer to management-level evaluators. The engi-
WinCC/PerformanceMonitor
neer can use the application environment integrated in WinCC to
WinCC/PerformanceMonitor V7.4 6AV6372-2DG07-4AA0
derive individual formulas for calculating performance indica- for WinCC V7.4
tors. WinCC/PerformanceMonitor V7.3 6AV6372-2DG07-3AA0
Management uses Web-based reporting without the need for for WinCC V7.3
installation on standard computers. For maintenance, the web as download
client of the WebNavigator can be used for analysis with the WinCC/PerformanceMonitor V7.4 6AV6372-2HG07-4AA0
bar (for performance), progression (Gantt) and table controls. for WinCC V7.4
Performance indicators can be displayed on local user inter- WinCC/PerformanceMonitor V7.3 6AV6372-2HG07-3AA0
faces using standard WinCC resources to keep machine for WinCC V7.3
operators up to date. Performance indicators in the on-site Option for
WinCC system keep machine operators up to date. The service WinCC/PerformanceMonitor
engineer can analyze the plant from his/her workstation using V7.3 and V7.4
the WinCC Client, the Webclient of the WinCC/WebNavigator, Basic package
for example. At the management level, it is possible to access
3
including 30 PerformanceMonitor
Web-based reports without the need for installation on standard Archive Tags
computers. 30 additive PerformanceMonitor 6AV6372-2CG20-0BA0
Archive Tags

Function 100 additive PerformanceMonitor


Archive Tags
6AV6372-2CG20-0CA0

Structuring of the production plant in equipment units 300 additive PerformanceMonitor 6AV6372-2CG20-0DA0
Archive Tags
constituting central elements for evaluation
1 000 additive 6AV6372-2CG20-0EA0
Use of structured tags in order to facilitate implementation of PerformanceMonitor Archive Tags
machine status models as download
WinCC tags are compressed to an operand using formulas 30 additive PerformanceMonitor 6AV6372-2JG20-0BA0
Archive Tags
Calculated operands are stored in the archive
100 additive PerformanceMonitor 6AV6372-2JG20-0CA0
Archived operands are used as input values for calculating Archive Tags
performance indicators 300 additive PerformanceMonitor 6AV6372-2JG20-0DA0
Archive Tags
Bar graphs for analyzing performance indicators and root
1 000 additive 6AV6372-2JG20-0EA0
cause determination (drill down) PerformanceMonitor Archive Tags
Indicator input values (operands) can be displayed if
required. WinCC/PerformanceMonitor
Upgrade
Tabular presentation of all operands (input values)
V7.x to V7.4
Progression diagrams (Gantt charts) of time-based operands Standard software 6AV6372-2DG07-4AX3
Cyclic or event-triggered calculation results are written to as download 6AV6372-2KG07-4AX3
WinCC tags Upgrade
WinCC Runtime, alarm logging and trend logging can utilize WinCC/DowntimeMonitor
cyclically-calculated values 7.2 and 7.3 to
WinCC/PerformanceMonitor
Database information and evaluations can be displayed at Standard software 6AV6372-2DG87-3AA0
every WinCC station as download 6AV6372-2KG87-3AA0
Information server reports can be displayed on independent
PC workstations

3/122 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Redundancy

Overview Function
Normally, two WinCC stations or process data servers run in par-
allel. Each station has its own process connection and its own
data archives. WinCC/Redundancy ensures automatic matching
WinCC of system and user archive data.
Clients
If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
LAN visualization and operation on every operator station.
WinCC
Servers
When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automat-
ically matched with the partner. This process runs in the back-
PROFINET ground and does not affect plant continuity. Once this is com-
plete, two equivalent servers/stations will be available again.
3
PROFIBUS
Communication with the SIMATIC S7 PLC can also be config-
ured with redundancy (an H Series SIMATIC S7 is required) by
G_ST80_XX_00084
plugging in two communication modules and configuring two
communication paths (S7-REDCONNECT software package).
The use of failsafe H Series SIMATIC S7 PLCs can, if required,
further increase availability at control level.

Ordering data Article No.

Option for SIMATIC WinCC, supporting the parallel operation SIMATIC WinCC//Redundancy
of two interfaced WinCC single-user systems or process data Option for SIMATIC WinCC V7.4, 6AV6371-1CF07-4AX0
Runtime software, single license
servers for mutual monitoring for 2 installations
If one of the two server PCs or one of the two WinCC stations Option for SIMATIC WinCC V7.3, 6AV6371-1CF07-3AX0
fails, the second one will take over control of the entire system. Runtime software, single license
Once the failed server or station is restored to operation, the for 2 installations
content of all the message and process value archives are as download
copied to it. Option for SIMATIC WinCC V7.4, 6AV6371-1HF07-4AX0
Runtime software, single license
One WinCC/Redundancy package is required for each for 2 installations
redundant pair of servers. Option for SIMATIC WinCC V7.3, 6AV6371-1HF07-3AX0
Runtime software, single license
Benefits for 2 installations

Increased system availability with continuous data integrity


Automatic changeover of client in the event of failure of a
server or failure of the communication to a server
Continuous operator control and visualization thanks to
automatic client changeover to the intact server
Automatic updating of all archives in the background after
rectification of the fault

Siemens ST 80 / ST PC 2016 3/123


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/SES (Sequence Execution System)

Overview Ordering data Article No.

SIMATIC WinCC/SES Sequence


Execution System
Software option package for the
sequential control of recipe and
sequence-based processes in
production, functional enhance-
ment for SIMATIC WinCC;
electronic documentation in
English, German
V7.4
Basic package 6AV6372-2DJ07-4AA0
For configuration of the Sequence
Execution System incl. 2 units 2)
Extension 5 units 6AV6372-2BJ07-4BA0
For increasing the number of
units 2)
as download

3 Basic package
Extension 5 units
6AV6372-2HJ07-4AA0
6AV6372-2JJ07-4BA0
V7.3
WinCC/SES 7.3 Basic Package 6AV6372-2DJ07-3AA0
For configuration of the Sequence
The WinCC/SES (Sequence Execution System) is designed for Execution System incl. 2 units 1)
the sequential control of recipe and sequence-based processes Extension 5 units 6AV6372-2BJ07-3BA0
in production. WinCC/SES is especially suitable for production For increasing the number of
plants in which dosing, mixing and material transport are import- units 1)
ant process actions. as download
Sequence controls can be structured with a high degree of Basic package 6AV6372-2HJ07-3AA0
flexibility, with the production steps being defined in a clear Extension 5 units 6AV6372-2JJ07-3BA0
engineering interface and freely combined to form individual Upgrades
process sequences. In addition both the step sequences and Basic Package Upgrade 7.4 6AV6372-2DJ17-4AA0
the parameters can be modified online during production runs. Extension 5 units Upgrade 7.4 6AV6372-2BJ17-4BA0
WinCC/SES helps the user to fine tune their production pro- as download
cesses by allowing them to easily combine automatic se- Basic Package Upgrade 7.4 6AV6372-2HJ17-4AA0
quences with manual interventions. This means that operators Extension 5 units Upgrade 7.4 6AV6372-2JJ17-4BA0
can react quickly and intervene in the running process, for ex- 1)
also requires the WinCC/User Archives option, STEP 7 V5.5 including CFC
ample when quality of the raw materials fluctuates or if a different V8 SP1. Based on SIMATIC S7-300 S7-315 or higher. Redundancy,
sequence among the production steps becomes necessary to WebNavigator, S7-1200/1500 are not supported.
facilitate more versatile production paths. 2)
additionally requires STEP7 V5.5. Based on SIMATIC S7-300 from S7-315
WinCC/SES also offers a high level of system availability and or higher, redundancy and WebNavigator are not supported.
rapid response times since the program sequence takes place
directly on the automation controller instead of on the PC.
WinCC/SES complies with the requirements of the
ISA-88 standard.

3/124 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Server

Overview

SCADA clients SCADA clients

LAN

WinCC server
(max. 18)

3
PROFINET

PROFIBUS

G_ST80_XX_00601
S7-300

S7-1500

S7-400

Option for SIMATIC WinCC, which permits the configuration of Client/server solution:
a powerful client/server system - One server can supply up to 64 connected clients with
One of the following operating systems must be available to process and archive data, messages, images and reports
install the option on the server: - Depending on the size of the plant, up to 18 servers can be
- Windows Server 2008 R2 SP1, employed.
- Windows Server 2012 R2, - 32 clients (max. 18 redundant WinCC servers) are possible
- Windows 7 SP1, per system
- Windows 8.1 or Windows 10 Requirement: Network connection (TCP/IP) between the
A maximum of 3 clients can be connected when using the server PC and the connected clients
non-server operating systems Windows 7 SP1, Windows 8.1 One license is required per server
and Windows 10.
A number of coordinated HMI stations can be operated in a
single group with networked automation systems

Siemens ST 80 / ST PC 2016 3/125


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/Server

Benefits Ordering data Article No.


Plant-wide scalability from the single-user system to the SIMATIC WinCC/Server
client/server solution Option for SIMATIC WinCC V7.4, 6AV6371-1CA07-4AX0
Significantly higher quantity framework, relieving the Runtime software, single license
individual servers and better performance due to distributing Option for SIMATIC WinCC V7.3, 6AV6371-1CA07-3AX0
the complete application or tasks over several servers Runtime software, single license
Low-cost configuration on the client is possible as download
(the minimum RC license is sufficient) Option for SIMATIC WinCC V7.4, 6AV6371-1HA07-4AX0
Runtime software, single license
Option for SIMATIC WinCC V7.3,
Application Runtime software, single license
6AV6371-1HA07-3AX0

In a complex plant, WinCC can also be configured as a


distributed system according to requirements:
Functional distribution (e.g. message servers, archive
servers, etc.) or
Distribution according to the physical plant structure
3 (e.g. body-in-white, paintshop, etc.)

Function
Each client can access more than one server at a time. Clients
can also be used for configuration on the server.
A configuration of WinCC clients as a central Web server - as a
distributed system if required - with an overview of all server
projects in the system is also possible.
For WinCC clients, only the smallest runtime license RT128 is
required. In order to also configure on WinCC clients, the small-
est complete license RC128 is required. Remote configuration is
possible if WinCC clients without their own project (Uniclients)
on the server project are configured. This makes it possible to
configure inexpensive operator and configuration stations in a
network.

3/126 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/TeleControl

Overview DNP3 telecontrol protocol


SIMATIC WinCC/TeleControl for WinCC V7.0 SP3 also supports
SIMATIC WinCC/TeleControl the DNP3 telecontrol protocol. Widely distributed outstations
SIMATIC WinCC/TeleControl for WinCC supports connection to (RTUs) can be controlled and monitored with the DNP3 telecon-
outlying stations (Remote Terminal Units = RTUs) via telecontrol trol protocol via serial or Ethernet TCP/IP communication links by
protocols. means of the telecontrol center in SIMATIC WinCC.
SIMATIC WinCC/TeleControl V7.0 SP3 Update 2 has been The control center integrated with SIMATIC WinCC/TeleControl
released for use with WinCC V7.3 Update 1 (SE). into the SCADA system is the master during telecontrol commu-
nication. The slaves are represented by the remote stations.
SIMATIC WinCC/TeleControl V7.0 SP3 Update 2 is not
SIMATIC S7-300/S7-300F and S7-400/S7-400F/S7-400H/
released for use with WinCC V7.4.
S7-400FH controllers as well as third-party RTUs can be used as
remote stations.
Benefits Further hardware and software components round off the range
SIMATIC WinCC/TeleControl for WinCC V7.0 SP3 cannot only of products:
integrate newly configured RTUs, it can also integrate units TIM communication modules
which already exist in outlying areas by means of DNP3 or
IEC 870-5-101/104 drivers. TCP/IP converters serial and MD modem modules

For communication with the outstations,


Mobile radio components (GSM/GPRS)
TCP/IP routers and switches
3
SIMATIC WinCC/TeleControl for WinCC V7.0 SP3 uses the
SINAUT ST7 and DNP3 protocols (both via serial and SCALANCE S612 and S613 security modules
TCP/IP communication connections) as well as IEC 870-5-101 Dedicated line accessories
(serial) and IEC 870-5-104 (Ethernet TCP/IP).
Cables
The serial RTU link is possible via the following components,
Engineering package for configuration of DNP3 data objects,
which can be connected directly via WinCC (single station or
stations, networks and connections as well as for diagnostics
server):
SINAUT TIM communication modules In order to implement telecontrol networks, basic topologies in-
(SINAUT ST7 telecontrol protocol) cluding point-to-point, multi-point, star and ring can be config-
ured using classic or TCP/IP-based media. These can be com-
TCP/IP serial converter (telecontrol protocols DNP3, Modbus bined flexibly depending on the existing infrastructure.
(not released for WinCC TC), IEC 870-5-101)
Classic WAN media:
Equipment from MOXA or Lantronix, for example, can be used
as TCP/IP serial converters. Dedicated line via modem, e.g. SINAUT MD2
Private radio networks
By means of Ethernet TCP/IP, the RTUs can be connected
directly or via TCP/IP WAN routers to the SIMATIC WinCC system Analog telephone network
bus (SINAUT ST7, DNP3, IEC 870-5-104 telecontrol protocols). Digital ISDN network
When using the SINAUT ST7 telecontrol protocol, the SINAUT
Mobile radio network GSM
TIM communication module can be used in addition to the
TCP/IP WAN router or as an alternative. TCP/IP-based WAN media:
Ethernet networks, e.g. SCALANCE X with fiber-optic cables
Application Industrial Wireless LAN with SCALANCE W
Telecontrol communication over the wide area network is largely Public networks and the Internet using DSL and/or GPRS
determined by the communication infrastructure which already
exists. Various transmission media such as dedicated line, ana-
log or digital telephone networks, wireless networks (GSM or
private), DSL or GPRS can also be combined with each other.
SINAUT ST7 telecontrol protocol
Detailed information for implementing telecontrol applications
with the SINAUT ST 7 telecontrol protocol via the Industry Mall.
IEC 870-5-101/-104 telecontrol protocols
Detailed information for implementing telecontrol applications
with the IEC 870-5-101/-104 telecontrol protocols via the
Industry Mall.

Siemens ST 80 / ST PC 2016 3/127


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/TeleControl

Function Prevention of data loss due to communications failure through


data backup in the RTU
Special characteristics of DNP3 communication Support of communication media with serial interface
Change-driven data transmission (dedicated lines, dial-up connections over analog telephone
- Change-driven transmission of process data between RTU lines and ISDN lines), various radio devices (standard, spread
and control center spectrum modulation), microwave and GSM
- Signaling of RTU, control center or connection failure Support for TCP/IP-based WANs (Wide Area Networks) such
- Automatic data updating for all communication partners as DSL, GPRS or Ethernet radio networks
involved following troubleshooting and following the startup Support for redundant communication connections
of the RTU or control center
Expanded communication diagnostics functions for
Chronological processing of process data RTU communication links
- Time tagging of all data frames at the place of origin allows
process data to be archived by the process control system Remote programming of RTUs
in the correct chronological order Support for different communication topologies
- The time of the DNP3 stations in the WAN can be synchro- Point-to-point, multidrop (multistation mode) and hierarchic
nized via SIMATIC WinCC (including summertime/wintertime network structures
switchover) High quality server redundancy scheme without data loss in
3 Local data storage
- The TIM communication module can temporarily store
the case of server failure
Through the support of communication protocols for RTUs such
(for several hours or even days) message frames should the
connection or the communication partner fail as IEC 60870-5 and DNP3, SIMATIC WinCC/TeleControl for
- Intermediate storage of message frames of lower priority in WinCC V7.0 SP3 supports the following advanced communica-
the case of priority-controlled data transmission (with dial-up tion concepts:
networks or quantity-dependent data transmission costs) Reduction in the transferred data volume by means of event-
controlled communication mechanisms for alarm and
Operating modes measured value information.
The DNP3 telecontrol protocol supports the following operating Time synchronization of RTUs and correct time stamping of all
modes: data in the RTU.
Polling Tolerance of lower bandwidth, high latency or lack of reliability
Polling with time slot procedure of communication lines
Multi-master polling with time slot procedure Prevention of data loss due to communications failure through
data backup in the RTU (not all non-Siemens RTUs support
Spontaneous mode in dial-up networks
this)
Spontaneous mode in the TCP/IP-based WAN
Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
Integration lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
Integration of SIMATIC WinCC/TeleControl for WinCC V7.0 SP3
into the WinCC SCADA system offers particular advantages for Support for TCP/IP-based WANs (Wide Area Networks) such
the sectors water/wastewater, as well as oil and gas, especially as DSL, GPRS or Ethernet radio networks
in the case of the following types of plant: Support for redundant communication connections
Freshwater treatment and distribution Expanded communication diagnostics functions for
Wastewater treatment plants RTU communication links
Oil and gas pipelines and water pipes Remote programming of RTUs
Oil and gas drilling fields and the associated treatment plants Support for different communication topologies Point-to-
point, multidrop (multistation mode) and hierarchic network
In these types of plant, remote outstations such as pumping sta- structures
tions, valve stations or automated stations for wellheads must be
High quality server redundancy scheme without data loss in
integrated.
the case of server failure
Through the support of communication protocols for RTUs such
as SINAUT ST7, SIMATIC WinCC/TeleControl for WinCC V7.0
SP3 supports the following advanced communication concepts:
Reduction in the transferred data volume by means of event-
controlled communication mechanisms for alarm and
measured value information.
Time-synchronization of RTUs and correct time stamping of all
data in the RTU.
Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines

3/128 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/TeleControl

Integration (continued)
Outstations/remote terminal units
SIMATIC WinCC/TeleControl for WinCC V7.0 SP3 supports the S7-400/S7-400F controller (SINAUT ST7, DNP3,
following preferred outstations for local distributed automation: IEC 870-5-101/104 telecontrol protocols);
Controller integrated into ET 200S (IEC 870-5-101/104 up to 500 I/O signals or approx. 5000 data points
telecontrol protocols); for cost-sensitive applications, up to S7-400/S7-400F redundant controller (IEC 870-5-101/104 and
approx. 30 I/O signals or approx. 200 data points DNP3 telecontrol protocols); up to 500 I/O signals or approx.
S7-300/S7-300F controller (SINAUT ST7, DNP3, 5000 data points
IEC 870-5-101/104 telecontrol protocols); for extremely Third-party station with the IEC 870-5-101/104 and DNP3
flexible configuration, up to 100 I/O signals or approx. telecontrol protocols (depending on type of station)
2000 data points
The following table provides an overview of the current
options for connecting to these outstations:
Spectrum of outstations and integration versions

3
Telecontrol protocol SINAUT ST 7 DNP3 IEC 870-5-01 IEC 870-5-04
Type of communication Serial Ethernet TCP/IP Serial Ethernet TCP/IP Serial Ethernet TCP/IP
Interface TIM 4R-IE TCP/IP WAN router TCP/IP serial con- TCP/IP WAN TCP/IP serial TCP/IP WAN router
or/and TIM 4R-IE verter router converter
RTU/interface ET 200S with - - - - IM 151-7 CPU or IM 151-8 PN/DP
integr. CPU (cor- IM 151-8 PN/DP CPU
responds to S7- CPU + SIPLUS RIC
314) as well as library
1 SI module +
SIPLUS RIC library
S7-300/S7-300F TIM 3V-IE TIM 3V-IE TIM 3V-IE DNP3 TIM 3V-IE DNP3 CP 341 CP 343 + IEC on S7
+ SIPLUS RIC or integr.
library PN interface
+ SIPLUS RIC
Library
S7-400/S7-400F TIM 4R-IE TIM 4R-IE TIM 4R-IE DNP3 TIM 4R-IE DNP3 CP 441 CP 443 + SIPLUS
+ SIPLUS RIC RIC library or
library integrated
PN interface
+ SIPLUS RIC
library
S7-400H/S7- - - TIM 4R-IE DNP3 TIM 4R-IE DNP3 ET 200M + CP 443
400FH 2 x CP 341 + + SIPLUS RIC
SIPLUS RIC library library
Third-party station - - Depends on type of station Depends on type of station
Dial-up lines - - - -
Dedicated line and radio
networks
Master/slave
Peer-to-peer - -
Mesh networks
Time tagging in RTU
RTU time synchronization
Data buffering in RTU 1) 1)
Routing with SIMATIC PDM - - -
International standard - -
1)
Data buffering is limited to two SIMATIC S7 data blocks. Depending on the
SIMATIC CPU, this corresponds to approx. 800 to 3200 buffered frames.

Siemens ST 80 / ST PC 2016 3/129


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/TeleControl

Ordering data Article No. Article No.

SIMATIC WinCC/TeleControl 7.0 6DL5000-7AA07-0XA5 SIMATIC WinCC/TeleControl 7.0 6DL5002-7AB07-0XA0


SP3 SP3
for WinCC Basic Engineering for Server Runtime (12 stations)
Software package with SIMATIC Software package with SIMATIC
WinCC/TeleControl for WinCC WinCC/TeleControl for WinCC
Engineering Software, 2 languages Runtime software, 2 languages
(English, German), executable with (English, German), executable with
Windows XP Professional/Server Windows Server 2003, single
2003, Floating License for one user; license for one user; electronic
electronic documentation documentation on CD/DVD,
on CD/DVD, 2 languages 2 languages (English, German)
(English, German) Type of delivery:
Type of delivery: License key memory stick,
License key memory stick, Certificate of License incl. terms
Certificate of License incl. terms and conditions, SIMATIC WinCC
and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP3
Data Medium Package V7.0 + SP3 and CD "WinCC/TeleControl Option
and CD "WinCC/TeleControl Option V7.0 + SP3"

3
V7.0 + SP3"
SIMATIC WinCC/TeleControl 7.0 6DL5002-7AE07-0XA0
SIMATIC WinCC/TeleControl 7.0 6DL5002-7AA07-0XA0 SP3
SP3 for Server Runtime (256 stations)
for Server Runtime (6 stations) Software package with SIMATIC
Software package with SIMATIC WinCC/TeleControl for WinCC
WinCC/TeleControl for WinCC Runtime software, 2 languages
Runtime software, 2 languages (English, German), executable with
(English, German), executable with Windows Server 2003, single
Windows Server 2003, single license for one user; electronic
license for one user; electronic documentation on CD/DVD,
documentation on CD/DVD, 2 languages (English, German)
2 languages (English, German) Type of delivery:
Type of delivery: License key memory stick,
License key memory stick, Certificate of License incl. terms
Certificate of License incl. terms and conditions, SIMATIC WinCC
and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP3
Data Medium Package V7.0 + SP3 and CD "WinCC/TeleControl Option
and CD "WinCC/TeleControl Option V7.0 + SP3"
V7.0 + SP3"

3/130 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/TeleControl

Ordering data Article No. Article No.


SIMATIC WinCC/TeleControl 7.0 6DL5002-7AF07-0XA0 TeleControl DNP3 Driver 6DL5101-8EX00-0XB0
SP3 Runtime license for one WinCC
for Server Runtime Single Station or one WinCC server,
(unlimited stations) single license for 1 installation
Software package with SIMATIC Requirement:
WinCC/TeleControl for WinCC Software SIMATIC WinCC/
Runtime software, 2 languages TeleControl 7.0 SP3 for
(English, German), executable with WinCC Server Runtime
Windows Server 2003, single (6, 12, 256 stations)
license for one user; electronic Type of delivery:
documentation on CD/DVD, License key memory stick,
2 languages (English, German) Certificate of License incl. terms
Type of delivery: and conditions
License key memory stick,
Certificate of License incl. TeleControl IEC 870-5-101/-104 6DL5101-8CX00-0XB0
terms and conditions, SIMATIC Driver
WinCC Data Medium Package V7.0 Runtime license for one WinCC
+ SP3 and CD "WinCC/TeleControl Single Station or one WinCC server,
Option V7.0 + SP3" single license for 1 installation
Driver software for telecontrol
protocols
6DL5101-8AX00-0XB0
Requirement:
Software SIMATIC WinCC/
TeleControl 7.0 SP3 for
3
TeleControl SINAUT Driver WinCC Server Runtime
Runtime license for one WinCC (6, 12, 256 stations)
Single Station or one WinCC server, Type of delivery:
single license for 1 installation License key memory stick,
Requirement: Certificate of License incl. terms
Software SIMATIC WinCC/ and conditions
TeleControl 7.0 SP3 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions

More information
For an overview of the complete performance range on the Technical Support (Hotline):
Internet, visit:
https://support.industry.siemens.com/My/ww/en/requests
Service & Support:
https://support.industry.siemens.com/cs/?lc=en-WW

Siemens ST 80 / ST PC 2016 3/131


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/User Archives

Overview Function
Input of parameter sets (e.g. operating parameters of a
machine) in WinCC, storage of the sets in the user archive,
and forwarding to the automation level
Continuous acquisition of production parameters by the
automation system and forwarding of the parameters to
WinCC at the end of the shift
Acquisition of batch data
Specification of production parameters
Management of warehousing data
WinCC user archives are created and assigned data in a user-
friendly way using a dedicated editor. Special ActiveX controls
are used for displaying data from the user archives at runtime.
Data sets and fields from user archives are linked to the process
via direct tag linking.
3 Import and export functions support read-in/out of data via ex-
ternal applications (e.g. MS Excel). Freely selectable filter crite-
Option for SIMATIC WinCC for managing data sets in user ria allow clear representation of data sets.
archives that contain related data.
WinCC and its automation partners (e.g. a SIMATIC S7 WinCC provides functions for free organization of the data stor-
controller) write these data sets and exchange them if age in the user archives that affect archives, data sets and fields.
required. Archives can thus be generated, opened, closed, or reset, and
data sets or field contents can be read, written or overwritten.
A license is only required for the server (or single-user
system). Sequence archives can accommodate batch data, shift produc-
tion data, or also product quality data, and meet legal obliga-
The WinCC/User Archives option can also be used tions for verification thanks to gap-free recording.
in the context of the WinCC/WebNavigator
(see also WinCC/WebNavigator option).
Ordering data Article No.

Benefits SIMATIC WinCC/User Archives


Storing and managing of any user data in data sets Option for SIMATIC WinCC V7.4, 6AV6371-1CB07-4AX0
Runtime software, single license
Flexible display using ActiveX controls Option for SIMATIC WinCC V7.3, 6AV6371-1CB07-3AX0
Simple linking of data set fields to the process via direct tag Runtime software, single license
linking as download
Import/export functions for further processing with other tools Option for SIMATIC WinCC V7.4, 6AV6371-1HB07-4AX0
Runtime software, single license
(e.g. MS Excel)
Option for SIMATIC WinCC V7.3, 6AV6371-1HB07-3AX0
Runtime software, single license

3/132 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebNavigator

Overview

WinCC
WinCC SCADA client WinCC WinCC
SCADA clients + web server web client web client

Internet

LAN

WinCC server
(max. 18)
3

PROFINET

PROFIBUS

G_ST80_XX_00599
S7-300

S7-1500

S7-400

Option for SIMATIC WinCC for operator control and monitoring Highlights:
of plants via the Internet, in-house intranet or LAN Installation of the Web server - in distributed systems - also on
Configuration from: a WinCC Client;
- a Web server with the SIMATIC WinCC software as a single- - Access to as many as 18 subordinate WinCC stations
user, client or server version and a Web client that enables (servers) possible
operator control and monitoring of a current WinCC project - Web clients offer common views of data on various WinCC
via an Internet browser with ActiveX support. The WinCC Servers
basic system does not have to be installed on the client - If you are using WinCC/Redundancy, the Web clients will
computer. It is also possible to use the Web client without also transfer via the subordinate WinCC servers (requires
Microsoft Internet Explorer. WebNavigator server to be installed on the WinCC Client
Licensing: (RT128) )
- A license is required in order to use the Web server. The - Separating the Web functionality from the WinCC data
number of clients with simultaneous access is licensed. servers makes the overall system safer and more scalable in
- Licenses are available for access to the Web server by 1, 3, respect of load. Integrated user management with WinCC:
5, 10, 25, 50, 100 or 150 clients. The configured WinCC operator authorizations are taken into
- Low-priced WebNavigator diagnostics licenses are account on the Web client.
available for the remote diagnostics via multiple, distributed Access to WebNavigator server from the WebNavigator
Web servers. TIA Portal series of products
Access to user archives
VB scripts are supported in the same way as the new objects
and RT functions in WinCC V7.x

Siemens ST 80 / ST PC 2016 3/133


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebNavigator

Overview (continued) Application


User-friendly services and tools for distributing customized In addition to the typical use of the WebNavigator in WANs
objects (controls, files) to Web clients can be supplied for use (Wide Area Network), the WebNavigator is also suitable for
as an integration platform. These components can then also solving especially low-cost applications. This especially in-
be integrated into cross-Web/Server navigation. cludes applications that have a pronounced distributed struc-
Distribution of load across a number of Web servers in order ture (water/wastewater, oil & gas), or in which access to process
to run several hundred Web clients in a single system; Web information is only sporadic (building management).
clients are distributed across Web servers automatically.
The WebNavigator also permits vertical integration, i.e. a net-
Version 7.2 supports Microsoft Internet Explorer Version 8.0 worked IT landscape with integrated data flow between the plan-
and 9.0, including tabbed browsing. A new license is not ning and operating levels within a company. Only a standard
required for separate tabs. browser is required for direct access to current process informa-
With the WinCC Web Viewer, the process screens can be tion.
displayed on the Web client independently of the Internet The Web Server can have its own dedicated direct process con-
Explorer. Settings for the client are made on the client itself. nection. An alternative is coupling via OPC or the use of a remote
The WinCC Web Viewer can also be used in conjunction with Web Server to a WinCC Client. This simultaneously increases
the Microsoft Terminal Service. security and reduces the communication load of the plant.
3 From version 7 on, the WebNavigator can also be operated in
"view only" mode and is thus used as tool for operating and
In addition to the Standard WebNavigator licensing there is the
so-called Diagnostics Client, with identical functions in principle,
navigating only via WinCC screens by means of the Internet but which is especially suitable for the following applications:
Explorer.
Remote diagnostics/operation of several unmanned WinCC
The cursor for View only mode can be selected according to stations
individual requirements.
Central control rooms which monitor multiple Web Servers on
Web server logins and logouts are recorded in the alarm and one user interface
audit archive.
Power Users that always require guaranteed access to the
There is a gadget available for the Windows 7 operating server regardless of the number of users already logged on to
system in which selected WinCC process screens can be the server.
displayed. The gadget does not require any additional
WebNavigator license. The WebNavigator server can be
selected direct using the gadget.
Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Runtime in the Web client can be terminated by means of
scripting.

Benefits
Operator control and monitoring across long distances and on
different platforms (PC, local panel, mobile PDA)
Large configurations with up to 150 operator stations
Fast updating rates thanks to event-driven communication
Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
Acceptance of configuration data for the Web, generally
without changes
Minimum maintenance costs thanks to centralized software
administration
High security standards and availability
- Increased security due to separation of WinCC server and
Web server (Web server in secure environment)
- Support for commonly used security mechanisms (routers,
firewalls, proxy servers)
- Access authorization and user administration
Printing from WinCC Controls in the WebNavigator Client and
WinCC RT Viewer. The printer is specified by the settings in the
Web Navigation interface and WinCC RT Viewer

3/134 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebNavigator

Design Function
Licenses for the WebNavigator The Web Configurator (Wizard) makes setting up and configur-
ing a WebNavigator Server very easy. WinCC process screens
The WebNavigator Client software can be installed as many to be visualized via the Internet are created as usual using
times as required without the need for a license. WinCC Graphics Designer. Under normal circumstances the
Server-based licensing; project can be worked on locally without modification. The Web
a license is required in order to use the WebNavigator Server. Publishing Wizard optimizes the screens for transmission and
Licenses are available for simultaneous access to the Web display on the Internet. A standard browser is all that is required
server by 1, 3, 10, 30, 100 Clients (countable licenses for V7.4) to display WinCC process screens on the Web Client. The MS In-
or 1, 3, 5, 10, 25, 50, 100, 150 Clients (for V7.3). ternet Explorer is used depending on the WebNavigator version
Diagnostics Client licensing; used (tip: start the Internet Explorer in full-screen mode with the
for optimum-cost access by one or a small number start parameter "-k").
of WebNavigator Clients to multiple Web servers The operator on the Web Client is integrated in the central
(for diagnostics, for example). This client license provides WinCC user administration and can operate and monitor the
guaranteed access to Web servers at any time. In respect of system according to the configured access rights.
function there is no difference compared with regular The WebNavigator supports all standard security mechanisms
WebNavigator Clients and the two can be mixed. that can be used for applications on the Internet, e.g. routers,
WebNavigator Clients can: firewalls and proxy servers. 3
Access a number of different web servers or New in V7.4
Access data on a number of higher-level WinCC stations WinCC/WebNavigator V7.4 allows access to process pictures
simultaneously via a remote Web server with the following Web viewers:
- Internet Explorer as of V10 (32-bit)
On the server side, only one WebNavigator Diagnostics Server - WinCC ViewerRT
license or, alternatively, one Standard WebNavigator license is
required. WinCC ViewerRT supports load balancing
Alternatively, a number of WebNavigator Servers with the same Log output on the Web client
WinCC project can be combined to create a "server farm". This Specify central Web settings for the STEP 7 multiproject.
means that it is possible for several hundred Web clients to have
access to the same database. The service ensures that the cli-
ents accessing are distributed evenly across all servers. If a
server fails the Web client is automatically forwarded to the next
available server.
In order to use this functionality you will need to install a Web
Load Balancing license on the Web servers involved. Each Load
Balance package contains 2 licenses.
An inexpensive expansion option for Web Load Balancing
is available for redundant WinCC stations on which the
WebNavigator is also installed. For this purpose, you need to in-
stall a Web Load Balancing Step Up license on the web servers
involved. Each Step Up package contains 2 licenses.
Thin Client solutions
The WebNavigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is re-
quired. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC, for example.
For this purpose, the Windows terminal services must be in-
stalled on the PC on which the Web client is installed. A Windows
Server 2003 or Windows Server 2008 (or higher) operating sys-
tem is required. Up to 25 thin clients can be connected to one
terminal server.
Applications:
Mobile devices
Handhelds
Rugged on-site visualizations
Hybrid configuration
WebNavigator and DataMonitor clients can be mixed in a single
system.

Siemens ST 80 / ST PC 2016 3/135


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebNavigator

Ordering data Article No. Article No.

WinCC/WebNavigator V7.4 WinCC/WebNavigator


Powerpacks V7.3
for WinCC V7.4 and WinCC V7.4
ASIA From 1 to 3 clients 6AV6371-1DH07-3LA0
1 client license (countable) 6AV6362-1AB00-0BB0 From 3 to 5 clients 6AV6371-1DH07-3AM0
3 client licenses (countable) 6AV6362-1AD00-0BB0 From 5 to 10 clients 6AV6371-1DH07-3MB0
10 client licenses (countable) 6AV6362-1AF00-0BB0 From 10 to 25 clients 6AV6371-1DH07-3BC0
30 client licenses (countable) 6AV6362-1AJ00-0BB0 From 25 to 50 clients 6AV6371-1DH07-3CD0
100 client licenses (countable) 6AV6362-1AM00-0BB0 From 50 to 100 clients 6AV9681-1DH07-3DG0
From 100 to 150 clients 6AV9681-1DH07-3GH0
as download
RT-SW, single license, license key as download
download. RT-SW, single license, license key
1 client license (countable) 6AV6362-1AB00-0AH0 download.
3 client licenses (countable) 6AV6362-1AD00-0AH0 E-mail address mandatory
10 client licenses (countable) 6AV6362-1AF00-0AH0 From 1 to 3 clients 6AV6371-1JH07-3LA0
30 client licenses (countable) 6AV6362-1AJ00-0AH0 From 3 to 5 clients 6AV6371-1JH07-3AM0
From 5 to 10 clients 6AV6371-1JH07-3MB0
3
100 client licenses (countable) 6AV6362-1AM00-0AH0
From 10 to 25 clients 6AV6371-1JH07-3BC0
WinCC/WebNavigator From 25 to 50 clients 6AV6371-1JH07-3CD0
Diagnostics Client
For WinCC from V7.4 From 50 to 100 clients 6AV9681-1JH07-3DG0
Standard scope of delivery 6AV6362-1BA00-0BB0 from 100 to 150 clients 6AV9681-1JH07-3GH0
as download 6AV6362-1BA00-0AH0 WinCC/WebNavigator
Diagnostics Client
WinCC/WebNavigator upgrade
For WinCC V7.3
Is included in the corresponding
WinCC upgrade from WinCC 6.2 Standard scope of delivery 6AV6371-1DH07-3EX0
and higher as download 6AV6371-1HH07-3EX0
WinCC/WebNavigator Load WinCC/WebNavigator
Balancing Diagnostics Server
Load Balancing 6AV6362-1FA00-0BB0 For WinCC V7.3
Load Balancing Step Up 6AV6362-1GA00-0BB0
Standard scope of delivery 6AV6371-1DH07-3FX0
as download as download 6AV6371-1HH07-3FX0
RT-SW, single license, license key
download. WinCC/WebNavigator upgrade
Load Balancing 6AV6362-1FA00-0AH0 Is included in the corresponding
WinCC upgrade from WinCC 6.2
Load Balancing Step Up 6AV6362-1GA00-0AH0 and higher
WinCC/WebNavigator V7.3 Load Balancing 6AV6371-1DH07-3JX0
For WinCC V7.3 and WinCC V7.3 Load Balancing Step Up 6AV6371-1DH07-3FJ0
ASIA as download
1 client license 6AV6371-1DH07-3LX0 RT-SW, single license, license key
3 client licenses 6AV6371-1DH07-3AX0 download.
5 client licenses 6AV6371-1DH07-3MX0 E-mail address mandatory
10 client licenses 6AV6371-1DH07-3BX0 Load Balancing 6AV6371-1HH07-3JX0
25 client licenses 6AV6371-1DH07-3CX0 Load Balancing Step Up 6AV6371-1HH07-3FJ0
50 client licenses 6AV6371-1DH07-3DX0
100 client licenses 6AV6371-1DH07-3GX0
150 client licenses 6AV6371-1DH07-3HX0
as download
RT-SW, single license, license key
download.
E-mail address mandatory
1 client license 6AV6371-1HH07-3LX0
3 client licenses 6AV6371-1HH07-3AX0
5 client licenses 6AV6371-1HH07-3MX0
10 client licenses 6AV6371-1HH07-3BX0
25 client licenses 6AV6371-1HH07-3CX0
50 client licenses 6AV6371-1HH07-3DX0
100 client licenses 6AV6371-1HH07-3GX0
150 client licenses 6AV6371-1HH07-3HX0

3/136 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebUX

Overview

WebUX monitor clients


Internet WebUX operate clients

WinCC
+ WebUX server

PROFINET 3

G_ST80_XX_00603
PROFIBUS
S7-1500 S7-300

The option WinCC/WebUX permits mobile, platform and No installation on the client is required for using the WebUX.
browser-independent operator control and monitoring via the WinCC/WebUX can be used independent of the industrial
Internet or the in-house intranet or LAN. sector, for example in service for the acknowledgment of alarm
messages, in quality assurance for monitoring important pro-
WinCC/WebUX is delivered with the WinCC Basic system. duction data, or in management for obtaining a quick overview
Following installation, the WinCC basic system operates as of key production figures.
WinCC/WebUX server.
The WebUX Server itself does not require a basic license. Clients
The pictures for the WinCC/WebUX are created using the WinCC that are simultaneously logged into the server are licensed.
Graphic Designer. The WinCC picture is stored in the corre- Regarding licensing, it is differentiated between Monitor clients
sponding format in the project through the picture property (only reading) and Operate clients (reading and writing of
Web-capable. Using the service platform IIS (Internet values). WinCC/WebUX can be used immediately due to a free
Information Server), the files are provided for the Internet. Monitor client that is included in the WinCC Basic package.

Benefits
WinCC Engineering Line management and plant operator
Fast configuration with WinCC Graphics Designer Mobile operator control and monitoring using commercially
No expensive training required due to the use of WinCC available mobile devices
standard tools Uniform look and feel both on the mobile devices and on the
Can be used without complex additional configuration on the WinCC station
client Secure communication via HTTPS und SSL certificates
Maintenance, servicing and IT No entry costs since the Monitoring client is included in the
WinCC basic package
No WinCC-specific installation on the clients required
Flexible licensing due to additive, Floating Client licenses
No WinCC-specific maintenance at the data terminal
equipment required Secured plant data as a basis for decision-making
The WinCC/WebUX Server version and version of the mobile Highlights
clients do not have to be the same Can be used on HTML5-capable and SVG-capable data
Standard user authorizations on the client suffice terminal equipment without installation on the client

Siemens ST 80 / ST PC 2016 3/137


Siemens AG 2016

HMI Software
SCADA system SIMATIC WinCC V7
SIMATIC WinCC options
WinCC/WebUX

Function Ordering data Article No.


Configuration via direct connection WinCC/WebUX 7.4
Language selection be setting the Web language in the User Monitor clients
Administrator
1 client (countable) 6AV6362-2AB00-0BB0
Use of the WinCC Classic design 3 clients (countable) 6AV6362-2AD00-0BB0
The following WinCC objects are supported 10 clients (countable) 6AV6362-2AF00-0BB0
30 clients (countable) 6AV6362-2AJ00-0BB0
WinCC standard objects except "Connector"
100 clients (countable) 6AV6362-2AM00-0BB0
WinCC Smart objects (picture window, I/O field, graphic
as download
object, status display, text list, multi-line text, combo box,
1 client (countable) 6AV6362-2AB00-0AH0
list box)
3 clients (countable) 6AV6362-2AD00-0AH0
WinCC Windows objects 10 clients (countable) 6AV6362-2AF00-0AH0
WinCC tube objects 30 clients (countable) 6AV6362-2AJ00-0AH0
100 clients (countable) 6AV6362-2AM00-0AH0
The WinCC AlarmControl can run as a WinCC Alarm Web control
in WebUX, with the following functional scope: Operate clients
1 client (countable) 6AV6362-2BB00-0BB0
3 Message lists: Message list, short-term archive list, and
long-term archive list
3 clients (countable)
10 clients (countable)
6AV6362-2BD00-0BB0
6AV6362-2BF00-0BB0
Message blocks with a few exceptions 30 clients (countable) 6AV6362-2BJ00-0BB0
Standard sorting 100 clients (countable) 6AV6362-2BM00-0BB0
Configuration dialog: some of the properties are available as download
1 client (countable) 6AV6362-2BB00-0AH0
Filter settings in the configuration dialog are supported during
3 clients (countable) 6AV6362-2BD00-0AH0
runtime
10 clients (countable) 6AV6362-2BF00-0AH0
Properties dialog with reduced selection of supported 30 clients (countable) 6AV6362-2BJ00-0AH0
properties 100 clients (countable) 6AV6362-2BM00-0AH0
The WinCC OnlineTrendControl can run as a WinCC OnlineTrend WinCC/WebUX 7.3
Web Control in WebUX, with the following functional scope: Monitor clients
Data source: Archive tags and online tags 1 client (countable) 6AV6372-2CH00-0BA0
Multiple trend windows 5 clients (countable) 6AV6372-2CH00-0CA0
10 clients (countable) 6AV6372-2CH00-0DA0
Multiple value axes and time axes
50 clients (countable) 6AV6372-2CH00-0EA0
Properties dialog with reduced selection of supported 100 clients (countable) 6AV6372-2CH00-0FA0
properties
as download
WinCC/WebUX V7.4 innovations 1 client (countable) 6AV6372-2JH00-0BA0
5 clients (countable) 6AV6372-2JH00-0CA0
The scope of functions of the platform-independent Web client 10 clients (countable) 6AV6372-2JH00-0DA0
has been extended by additional controls. 50 clients (countable) 6AV6372-2JH00-0EA0
(Including OnlineTable Web Control, Ruler Web Control, 100 clients (countable) 6AV6372-2JH00-0FA0
Slider Control, Digital/Analog Clock Control, Gauge Control,
WebBrowser Control). Operate clients
1 client (countable) 6AV6372-2CH10-0BA0
Furthermore, dynamization can be implemented with VBScript 5 clients (countable) 6AV6372-2CH10-0CA0
or the dynamic response dialog. Version-independent license 10 clients (countable) 6AV6372-2CH10-0DA0
packages can also be cumulated, and WebNavigator and 50 clients (countable) 6AV6372-2CH10-0EA0
WebUX licenses can now be combined. 100 clients (countable) 6AV6372-2CH10-0FA0
Further innovations include: as download
Touch operation in process pictures and WinCC controls 1 client (countable) 6AV6372-2JH10-0BA0
5 clients (countable) 6AV6372-2JH10-0CA0
User administration via SIMATIC Logon 10 clients (countable) 6AV6372-2JH10-0DA0
System events for user logon and logoff 50 clients (countable) 6AV6372-2JH10-0EA0
Automatic conversion of dynamic response dialogs in 100 clients (countable) 6AV6372-2JH10-0FA0
VBScripts
Note:
Supported Graphics Designer objects have been enhanced
(application window, bars, support for the "operation One Monitor Client License is included in the WinCC Basic
message" object property for all objects, and "operation log" Package. The licenses are additive, i.e. one 10 Client license
for the I/O field) and one 50 Client license permit access by 60 clients.
Note: License from V7.3 can continue to be used in V7.4 without
upgrading.
Browser-dependent display is occasionally possible Minor
differences in display and behavior are possible for the different
browser versions.

3/138 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
WinCC add-ons and partner management
Introduction

Overview
Premium Add-ons for Connectivity:
PM OPEN IMPORT system software
enables the WinCC flexible archives to be automatically read
into the WinCC system.
CC PM OPEN IMPORT system software
Win d-on
ad offers a flexible, low-cost solution for exporting current
CC CC process data and archive data from WinCC into freely struc-
Win tion Win tion turable text files.
op op
CC
Win ic SW PM OPEN TCP/IP system software
a s
b C, RT offers a low-cost solution for connecting computer systems
R
(PPS, laboratory, logistics and quality management systems,
CC etc.) to the automation and process control level.
Win d-on
ad CONNECT ALARM Historian system software
CC
Win tion permits the flexible importing of messages and alarms from
op WinCC and WinCC flexible into the SIMATIC IT Historian.
TOP Server
is a proven OPC data integration platform with a large number
3
CC of OPC device drivers.
Win d-on
ad TOP Server UCON
G_ST80_XX_00175

enables separate OPC device drivers to be created by Point-


Click configuration.
Premium Add-on for process management:
PM-ANALYZE
is used for locating sources of error or weak spots in plants by
analyzing messages and process values.
WinCC Premium Add-ons Solutions for all sectors and PM CONTROL system software
technologies is a cross-industry recipe system for user-friendly creation
The basic system is designed to be independent of any specific and management of recipes with integrated order control.
technology or industrial sector, to be modular and flexibly ex- PM QUALITY system software
pandable and to permit not only simple single-user applications is a modular and sector-independent archive system for order-
in machine construction, but also complex multi-user solutions related or batch-related acquisition of process and production
or even distributed systems with several servers and clients in data.
plant engineering. WinCC Premium Add-ons are supplementary
products that have been created by competent partners working Premium Add-on for sector products:
in the specifc sectors and technologies and represent interest- ACRON 7 for WinCC
ing expansions for WinCC. is used for long-term archiving and logging of process data for
WinCC Premium Add-ons are not DF (Siemens) products, but small to medium-sized plants, specifically in the water supply
the products of partners who are committed to complying with and treatment industry.
certain quality features and boundary conditions. The Premium Sm@rtlib function library
Add-ons are checked, for example, in the Siemens Test Center provides function blocks for S7-300/400 as well as faceplates
for their compatibility with the basic WinCC system and sup- and icons for WinCC and WinCC flexible from the areas of
ported in the first instance by the central Hotline. As they are im- process industry, HVAC, pharmaceuticals and energy.
portant application- and sector-specific add-on products for Premium Add-on for configuration tools:
SIMATIC WinCC, they are marketed jointly by Siemens and the
respective add-on suppliers. The WinCC Premium Add-on DCC TranslationEditor
products can be found on the Internet (see Further Information) for the efficient, secure translation of multilingual visualizations
and in the "Online WinCC Premium Add-on Catalog". with in-built features for quality assurance.
Premium Add-on for diagnostics and maintenance:
ACC Alarm Management System
enables messages to be passed from the visualization system
to mobile radio call receivers, such as cell phones or pagers,
etc.
PM MAINT system software
is a sector and technology-neutral maintenance system for
use in preventive maintenance.

Siemens ST 80 / ST PC 2016 3/139


Siemens AG 2016

HMI Software
WinCC add-ons and partner management
Introduction

Overview (continued) More information


Competent partners WinCC Competence Centers
With SIMATIC WinCC, you not only get excellent products to suit More information is available on the Internet at
your requirements, but we will also support you with selecting a http://www.siemens.com/wincc-coc
partner for your automation solution. In our global network of
Siemens Automation Solution Providers you will always find Siemens Solution Partner Automation
competent partners in your neighborhood. In addition, Siemens-
internal WinCC Competence Centers and WinCC Specialists More information is available on the Internet at
support external system integrators with WinCC customer and http://www.siemens.com/automation/solutionpartner
industry-specific implementation of efficient solutions. WinCC Specialists
WinCC Competence Centers More information is available on the Internet at
Mannheim: Process management http:/www.siemens.com/wincc-specialists
Sector-independent solutions and products in the fields of WinCC Premium Add-on
production, environment, maintenance and diagnostics
More information is available on the Internet at
Connectivity tools, system integration, connection to SAP R/3 http://www.siemens.com/siplus-extreme
3 Support of FDA validation and WinCC ODK
Stuttgart: Production technology
Solutions for maintenance management
Alarm management
Plano, Texas (USA)
Migration of FactoryLink to SIMATIC WinCC
Support for customers with migration projects
Optimization of automated migration tools
Support for FactoryLink customers with CSS contracts

3/140 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Overview Benefits
SIMATIC WinCC Open Architecture is a SCADA system for visu- Efficient engineering and flexible plant expansion
alizing and operating processes, production flows, machines - Object orientation
and plants in all industrial sectors. - Unlimited number of data points
- Mass engineering
SIMATIC WinCC OA is built consistently on object-oriented - Multilingual with UTF-8 support
structures. Due to this consistent and well-considered use of ob-
ject-oriented structures, from process images to the database, Object-oriented data model
the engineering costs improve for SIMATIC WinCC OA custom- - Mapping of setpoint values and measured values for a
ers. physical plant object onto a structured data point
- Data point comprises a tree structure with data point
Distributed systems enable the connection of up to 2 048 auton- elements
omous SIMATIC WinCC Open Architecture systems via a single - The individual process values are mapped onto the data
network. Each subsystem can be configured either as single- point elements
user or multi-user system, each of which may be redundant or - Any number of data points can be instanced from one
non-redundant. defined data point structure (data point type), e.g. 20 pumps
of the same type.
Current version: SIMATIC WinCC Open Architecture V3.14 - Data point types can be embedded in other data point types,
3
Runs under: which enables more complex plant objects to be generated
Windows 10 (64-bit) (e.g. one pump station comprises 2 pumps).
Windows 8.1 Enterprise/Professional (64-bit) - Graphical plant symbols can be linked with a data point
type. They only need to be drawn once, but can be used for
Windows 7 Ultimate/Enterprise/Professional SP1 (64-bit) all instances of the linked type.
Windows 7 Ultimate SP1 (64-bit) (released for IPC 227E / 277E - Savings in engineering outlay.
only) Freely scalable
Windows Server 2012 R2 (64-bit) - From a small single-user system up to a networked,
Windows Server 2008 R2 (64-bit) redundant high-end system
- Distributed systems of up to 2 048 servers
Red Hat Enterprise Linux 7.1 (64-bit)
Platform-independent
OpenSUSE 13.2 (64-bit) - Available for Windows, Linux, iOS and Android
CentOS 7.1 (64-bit) Native 64-bit support
VMWare ESXi Version 6 - More system memory is usable, due to native 64-bit support
Note: - This means that larger data quantity structures per server
can be processed
Native 64-bit support. Maximum fail-safety and availability
- Hot standby redundancy
- Disaster recovery system
- SIL3 certification according to IEC 61508
Platform for customized solutions
- Quick and easy implementation of new processes
- Swift adaptation of the control and visualization of the plant
to current market requirements
- Company-internal programming and in-house develop-
ments enable independence and protection of intellectual
property
- Structure of standardized solutions permits continuous use
- Support of brand-labeling
- Individual brand names for OEM developments
Openness thanks to comprehensive driver and interface
options:
- SIMATIC S7 TCP/IP, Modbus TCP/IP, Ethernet/IP,
SNMP, BACnet, OPC DA Client & Server,
OPC A&E Client & Server, OPC UA Client & Server (DA, AC),
SSI driver, IEC 60870-5-101, -104, DNP3, SINAUT, IEC
61850/61400, RK512, TLS, Teleperm M, API, Cerberus
Seamless traceability of system states by means of
high-performance archiving:
- Data archiving in value archives (internal database format)
- Data archiving in an Oracle database

Siemens ST 80 / ST PC 2016 3/141


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Benefits (continued) Design


Expandable by means of add-ons and solution frameworks: SIMATIC WinCC Open Architecture is available as a single-user
- Add-on for integration of video management systems runtime license, multi-user runtime license, Web Client license,
(VIDEO) and parameterization and development license. With SIMATIC
- Add-on for increasing the availability (DRS, etc.) WinCC Open Architecture the required license is determined,
- Add-on for clarity in distributed systems (GIS Viewer, etc.) among other things, according to the number of inputs and out-
- Add-on for efficient maintenance management (AMS, puts (I/O).
Scheduler, etc.)
- Add-on for mobile operability (Web Client, Mobile Client, An "I/O" refers to a data point element (DPE) whose content is ex-
etc.) changed either by means of drivers (e.g. S7 driver communi-
- Add-on for efficient building automation technology cates with a PLC), with other software systems. Internal data
(BacNet, etc.) point elements, i.e. DPEs without communication to the outside,
- Mobile App SIMATIC WinCC OA Operator are not counted for licensing. The licenses are available either
with an unlimited number of I/Os or with limitations of 500 to
Application 250 000 I/Os.
The multi-user runtime license allows working simultaneously
The SCADA system SIMATIC WinCC Open Architecture ad- from different PCs, with the licensing taking place via the server.
3
dresses applications with high demand for customer-specific The active clients are then counted. The web client and the ul-
adaptations, large and/or complex applications, as well as proj- tralight client enable the visualization and operation of process
ects that demand special system requirements and functions. pictures over an exclusively HTTP connection between the
SIMATIC WinCC Open Architecture demonstrates its high per- server and the respective web client. The parameterization and
formance in networked and redundant high-end control systems development licenses extend a runtime license with the option of
in particular. Integrated, high-performance communication is configuration and parameterization. They each require a server
guaranteed from the field level to the control station, from the license.
machine to the company headquarters. In every situation, high
availability, reliable information, fast interaction, and user friend- Function
liness are guaranteed. Applications can also be changed with-
out interrupting the process. Profitability, efficiency and safety SIMATIC WinCC Open Architecture is a very modular SCADA
are therefore always in equilibrium. SIMATIC WinCC Open system. The required functionalities are realized by specific,
Architecture displays its reliability in a wide range of business- functional entities created for various tasks. In SIMATIC WinCC
critical applications. Open Architecture these units are called "Managers" they are
also independent processes in software terms.
With SIMATIC WinCC Open Architecture, ideas can be quickly
and easily converted into new applications. SIMATIC WinCC WinCC OA Manager Task
Open Architecture is open for independent in-house develop- Event Manager (EV) The Event Manager (EV) is the processing center in
ments and also enables own product branding. WinCC OA. This unit provides a constantly updated
image of all PowerTags in the memory. Each other
Thanks to its special system properties, SIMATIC WinCC Open functional unit (Manager) that wants to access the
Architecture meets the highest demands especially in the case data receives it from the process image of the Event
of traffic solutions, building management systems and supply Manager and does not have to communicate
systems (power, water, oil and gas, etc.). directly with a controller. Conversely, a command
from an operator station is initially set only as a
value change in the process image of the Event
Manager. The associated driver then forwards it to
the corresponding target device (e.g. PLC) auto-
matically.
The Event Manager is a kind of central data distrib-
utor, in effect the communication center for WinCC
OA. Furthermore, this Manager also carries out the
alarm handling and can execute various arithmetic
functions autonomously.
Driver Manager (D) The lowest level in a WinCC OA System is repre-
sented by the process connections, referred to in
WinCC OA as drivers (D). These are special pro-
grams that handle the communication with the con-
trol and field level. Since numerous different forms
of communication are possible with the PLCs or
telecontrol nodes, there are different drivers that
can be selected. In very simple terms, the driver is
a unit for converting a particular protocol into the
internal communication form of WinCC OA. The
driver reads the current states, measurement or
counter values from the field and in the opposite
direction it forwards commands and setpoints to the
lower-level controllers (= the term "control" should
be used here and below to represent all possible
devices of the basic automation (PLC, DDC, tele-
control system, etc.)).

3/142 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Design (continued)
WinCC OA Manager Task
Data Manager (DB) The Data Manager (DB) represents the link to data- Visualization, Operation
UI UI UI
base. On one hand, it involves the parameterization User- User- User- UI = Runtime
data of an application that is to be stored in such a interface interface interface GEDI = Graphical Editor
database. On the other hand, it involves the histori- Editor Runtime Runtime PARA = Data base Editor
cal recording of changes in values or alarms. If a
user wishes to query historical data at a later date,
then the Data Manager completes this request and
not the database itself. Processing, Control
CTRL API
Control Manager WinCC OA has numerous options for implementing Control API Control = Script language
manager manager Manager
(CTRL) your own algorithms and processing. The two most API = Application
important are the internal language control (CTRL) Programming
and the general application programming interface Interface
(API).
Control is an extremely powerful scripting language.
Process Image, History
The processing is interpretative, so that no compila- DB EV CON
tion is required. The syntax is almost identical with Database Event Connect. Event manager = Communication
ANSI-C, with some modifications for simplification. Manager manager to other and Alarming
This is a fully developed, procedural high-level lan-
guage with multi-threading (= quasi-parallel pro-
cessing of individual programs; the system itself
systems Data manager, = History
RDB
3
carries out the processing check). The language

G_ST80_XX_00463
offers a comprehensive function library for tasks of Process interface
the control and visualization technology. Control can D D D
Driver Driver Driver Driver: PLC, field busses, DDC,
be used as a stand-alone process (Control Man- Telemetry/RTU, special drivers
ager), for animation and user interface design or for
standardized, data object-oriented processing
functions.
The API (WinCC OA API) represents the most
powerful form of functional expansion. It is config- A WinCC OA System consists of function-specific units, the managers
ured as a C++ class library and allows the software
developer to implement individual functions as an
independent, additional manager (forecast system, For special tasks such as redundancy, management for
simulation, tools, proprietary databases, etc. ). distributed systems, web server, reporting, simulation, COM
User Interface The interface to the user is created by the User etc., further managers are available.
Manager (UI) Interface Manager (UI). This comprises a graphics
editor (GEDI), a database editor (PARA) or the
The powerful configuration functions contribute to a reduction of
general user interface of the application (Vision engineering and training overheads and lead to increased
module). The User Interface serves to display flexibility and operational reliability.
values, issue commands or track alarms in the
alarm list. Trends and reports are also usually part
of the UI. From a programming viewpoint, the user
interaction in WinCC OA is completely isolated from
the background processing this is merely a view
of the data of the current process image or the
history.

Siemens ST 80 / ST PC 2016 3/143


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Design (continued)
Special functions Task Special functions Task
Access to external The database interfaces offer the possibility of SMS Allows the sending and receiving of text messages
databases access to external databases. with WinCC OA.
Under Windows, the link is established via the ADO
Standard. ADO (ActiveX Data Objects) is an inter- Encryption of panels Allows your panels or scripts to be encrypted,
face developed by Microsoft for vendor-indepen- and CTRL scripts/ thereby protecting your knowledge and work.
dent access to data sources of all types, primarily libraries
databases. The data source for ADO is an OLE DB Script Wizard Easy-to-use tool that simplifies the creation of
Provider, although ODBC-compatible databases animated, graphical plant symbols, which saves
can also be addressed via an internal wrapper. time during engineering.
In Linux, the Qt library is used as an interface to
relational databases. Access in this case is either Simple Symbols Basic package of plant symbols that have been
direct via the native DB-API or via ODBC. created using the script wizard. These can be
adapted quickly and easily to the specific require-
Application The API offers a series of functions that enable ments of the customer.
Programming WinCC OA to be extended with special managers.
Interface (API) A manager means a program that communicates Easy Faceplates Simple parameter assignment of predefined pop-up
with the system by via a protocol defined by windows that display details of the associated plant
WinCC OA. symbol. Without any additional drawing outlay,

3 COM (Component
Object Model)
This is a specification for the development of
modular software components that can be used by
several standard functions per object can be
activated for the detail view (alarm display, trend
display, measured value table, setpoint value table,
each COM-compatible application. COM compo- address table, notes).
nents can easily be integrated into such applica-
tions and can even be removed from an application Drag and Draw Several representative graphical objects can be
during runtime. COM components can be pro- defined and configured for each plant object in the
grammed in a host of different languages, even data model (data point type). These are pre-config-
though C++ is usually used for this purpose. The ured and need only be moved to the panel via
specifications OLE, ActiveX and DirectX are based drag-and-drop when the plant pictures are drawn.
on the COM technology. This saves valuable time during engineering.
Control expansion Expansion that allows C++ functions to be added to Distributed systems Permits the coupling of two or more autonomous
the programming language. (see the diagram WinCC OA systems via a network. Each subsystem
below) of a distributed system can be configured either as
Panel topology/ Generation of panel hierarchies/topologies in a single-user or multi-user system, each of which
summation signal existing or new projects and automatic creation of may be redundant or non-redundant. A sub-system
summation signals of the alarm data points that are in this context means a server on which an Event
located in the panels of the topology. Manager is running, whereby in case of redundancy
Redundancy The failure safety in a redundant system is imple- both redundantly operating servers are considered
(see figure below) mented by means of hot standby. Hot standby is a as one system.
hardware-independent solution for high availability.
This is a safety concept that consists of two inter-
connected server systems. Both servers are con-
stantly in operation and are subject to the same
functional loading (but only one server is ever
active; the second compares the data with the pri-
mary unit at runtime). On the failure of one unit, an
"on-the-fly changeover" takes place and the previ-
ously passive server assumes the leading role. This
guarantees access to data or functions at all times.

3/144 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Design (continued)
Operator station 1 Operator station 2

UI UI
User- User-
interface interface
RuntimeE Runtime

Server 1 Server 2
Message direction

CTRL
Control
CTRL
Control
3
manager manager

EV
Event
manager Event DB
DB REDU REDU
Database Redundancy Redundancy manager Database
manager manager manager manager

G_ST80_XX_00479
D D
Driver Driver

ACTIVE Process connection Process connection HOT-STANDBY

The diagram shows a detailed representation of the two In the case of redundant operation, the UIs of both operator
computers Server 1 and Server 2. Server 1 is in the management stations are connected to both Event Managers, however only
mode (active) and Server 2 is in hot standby mode (passive). the data of the active system is displayed on both UIs. The Event
Manager of the passive system is restricted exclusively to
communication with the Event Manager of the active system for
comparison of the process data (it sends no data to the
connected UIs or it discards messages from the drivers this
can be seen in the figure with the switches on the UIs or on the
passive Event Manager).

Siemens ST 80 / ST PC 2016 3/145


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Integration
Integration in automation solutions Protocol Description
SIMATIC WinCC Open Architecture is an open SCADA system S-bus The WinCC OA S-bus driver is used to link SAIA
with comprehensive drivers and flexible options for connection PCD control devices to WinCC OA projects. Client
to other external systems. mode of the SAIA S-Bus driver is used. Communi-
cation is carried out using the UDP; the serial
Depending on the communications protocol and the bus version of the protocol is not supported.
physics used, specific drivers are used in each case: Serial: RK512/3964R Is used for interfacing a PLC via the 3964R/RK512
Serial protocols: RK512, 3964R, etc. protocol

Ethernet: Industrial Ethernet (S7), Modbus TCP Cerberus Cerberus is a fire, intrusion and gas alarm system.
The Cerberus driver guarantees communication
(OpenModbus), Ethernet IP (AB), etc. to and from the central fire alarm systems and
Telecontrol systems: SINAUT, SSI (Ethernet), building security facilities in the event a fire, gas
IEC 61850/61400, IEC 60870-5-101, IEC 60870-5-104, etc. or intruder alarm.

Vendor-independent interfaces: OPC UA, etc. SSI Is used for the interfacing of SAT remote control
systems. The data is exchanged via the LAN
In SIMATIC WinCC Open Architecture, several drivers can be (Ethernet, IEEE 802.3); the frame formats used are

3 operated in parallel. These can be of the same type or also of the SSI formats defined by SAT. The SK 1703 tele-
control components with a suitable communica-
different types. It is possible in a SIMATIC WinCC Open tion card (KE/ET) are supported.
Architecture system, for example, to establish connections via
the S7 protocol to a SIMATIC controller, via IEC 60870-5-104 to IEC 60870-5-101, -104 IEC drivers are standardized telecontrol drivers
that can process proprietary frames. IEC stands
a telecontrol system, and via OPC DA to any OPC server at the for International Electrotechnical Commission, the
same time. international standardization committee for
electrical engineering.
Coupling overview IEC 60870-5-104 for data exchange via TCP/IP
IEC 60870-5-101 for serial connection
Protocol Description
IEC 61850/61400 IEC 61850 Client and IEC 61400 Client defines an
S7 TCP/IP TCP/IP driver for Siemens Industrial Ethernet architecture for satisfying the requirements of
electrical substation automation. It defines a data
OPC Client Compatibility with specifications DA 1.0 and model and the communication services for inter-
(Data Access) 2.05a action with and between the elements of a substa-
Connection to inproc, local or remote server tion, such as power supply units, circuit-breakers,
Connection with up to 20 servers at the same protective devices etc. A description language
time and a system configuration language (SCL) have
Monitoring of the connection to the server and been defined for technical purposes.
automatic reconnection if the connection is
interrupted. DNP3 The DNP3 (Distributed Network Protocol 3) driver
Address browsing if supported by the server. is an open, rugged and modern protocol which
Benefits of the CALL-R functionality for CALL-R exhibits characteristics and strengths similar to
servers (simplified parameter assignment) the IEC driver. The transfer of any number of
frames with different data types takes place
OPC Server Corresponds to Data Access 2.05a specification between the WinCC OA System (Master) and the
(Data Access) (reading/writing of online values). remote stations (Slave).
Is to be started as a manager just like other
drivers. SINAUT SINAUT (SIemens Network AUTomation) is a
The provided DPEs (server -> client) can be eas- communication protocol for automated monitoring
ily and quickly defined via data point groups. and control of remote process stations on the
DPEs can be declared as readable (read-only basis of SIMATIC S7. Communication takes place
access is permitted; Group OPCRead) or as writ- via TCP/IP.
able items (Group OPCWrite).
Clients can browse the WinCC OA OPC Server SNMP Manager & Agent SNMP (Simple Network Management Protocol) is
hierarchically. a protocol for monitoring network elements
(servers, workstations, routers, switches, hubs,
OPC Alarms & Events OPC Alarms & Events (abbreviated to OPC A&E) etc.) and their functions.
is, in addition to Data Access, a further standard SNMP Manager supports SNMP V1, V2, and V3
for performing central alarm management on a SNMP Agent supports SNMP V1 and V2
cross-vendor basis. OPC A&E is used to ensure
the link to other control systems and the display of BACnet over IP driver BACnet (Building Automation and Control Net-
alarms/events in a hierarchical system. works) is a standardized protocol for building
automation and has been set by the ASHRAE
OPC Historical Data OPC Historical Data Access (OPC HDA) is used (American Society of Heating, Refrigerating and
Access to exchange archived process data. This is in Air-conditioning Engineers) as a guideline to pro-
contrast to the OPC Data Access (OPC DA) vide a uniform and cross-company standard for
specification that deals with real-time data. data communication within and between building
automation systems.
OPC UA The OPC UA client supports the OPC UA stan-
(Unified Architecture) dards Data Access and Alarms & Conditions (AC) The BACnet Standard 2004 is supported in accor-
and Historical Access (HA). dance with the PIC list (see product documenta-
tion)
Modbus TCP Modbus/TCP is based on the serial Modbus
protocol, which was adapted for TCP/IP. The Further drivers on request or via C++ API
Modbus/TCP driver can be used simultaneously
for Modbus/TCP or UNICOS.
Ethernet/IP Ethernet/IP is used for communication with
several PLC generations and families from
Rockwell Automation / Allen Bradley. The protocol
is part of the application layer and is based on the
standard TCP/IP network protocol.

3/146 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Technical specifications
Type SIMATIC WinCC Open Architecture V3.14 Type SIMATIC WinCC Open Architecture
Operating system Windows 10 (64-bit) Functionality/quantity
Windows 8.1 Enterprise/Professional (64-bit) structure
Windows 7 Ultimate/Enterprise/Professional Number of messages 150,000 2)
with SP1 (64-bit) Message text System-limited 1)
Windows 7 Ultimate SP1 (64-bit) (number of characters)
(released for IPC 227E / 277E only)
Message archive System-limited 1)
Windows Server 2012 R2 (64-bit)
Process values per 1 process value + up to 32 alarm associated
Windows Server 2008 R2 (64-bit)
message values per message
Red Hat Enterprise Linux 7.1 (64-bit)
Constant load of 500/s 2)
OpenSUSE 31.2 (64-bit) messages, max.
CentOS 7.1 (64-bit)
Message burst, max. 15,000/10 s every 5 min 2)
VMWare ESXi Version 6
Archives
PC hardware requirements 1)

3
Archive data points Max. 250,000 per server 2)
Processor type Intel Pentium or equivalent
Archive types < 20 parallel logs, different retention period for
Minimum Intel Pentium IV 1.6 GHz (or better)2)3) each log
Recommended Client: Intel Pentium IV/Core2/i3, 2 GHz2)3) Data storage format Oracle or file system
Server: Intel Core i3 CPU Dual, 3 GHz2)
Server large system4): Intel(R) Core(TM) i5/i7 Measured values per Server/single-user station: 7,000/s 2) 3)
CPU Dual / Quad, 3 GHz2)3) second, max.

RAM User archive

Minimum 2 GB 2) Archives System-limited 1)

Recommended Client: 2 GB 2)3) Type SIMATIC WinCC Open Architecture


2)3)
Server: 8 GB Table size System-limited by ORACLE database
Server large system: 16 GB 2)
Graphics system
Hard disk
(available memory for Number of screens System-limited 1)
installation)
Number of objects per System-limited 1)
Minimum HD with 800 MB available 2) screen
Recommended Server large system with local logging: Number of controllable System-limited 1)
SCSI LVD Controller, WIDE SCSI / LVD HDD or fields per screen
comparable storage system with at least
500 MB of available space 2) PowerTags < 750,000 per server 2)

Screen and graphics card User administration


(TrueColor) User accounts < 4096
Minimum 1024 x 768 2) Configuration languages 2 (De, En)
Recommended 1280 x 1024 2) Runtime languages 40 (of which 8 Asian)
Mouse and keyboard Mouse, keyboard Multi-user system
DVD drive for software installation Server < 2048 2) 4)
Local power user rights for installation Number of clients < 244 per server 2) 5)
for operation
1) 1)
For actual use in plants, the hardware requirements are largely dependent Dependent on the available storage space
on the project size and the dynamic response of the process variables. 2) Dependent on the system configuration and the system load (due to the
Whenever possible, use rugged, high-quality hardware with corresponding event-oriented architecture, the system load is essentially determined by
functionalities such as redundant power supply units or RAID hard disks. the change rates of the values to be processed)
WinCC OA supports dual and multi-processor mode and benefits signifi- 3)
cantly from the fact that each WinCC OA Manager can be assigned to one By means of high-performance hardware configuration (one archiving
processor core as a system process. At the same time, however, it is cluster and approx. 120 distributed systems that archive parallel values in
important that the individual cores offer the highest possible performance the cluster): 200,000 archived value changes per second
(high clocking), since load-critical core processes such as the event 4) Physical limit: <2048, in practice systems have already been implemented
manager run on exactly one core (for this reason, multi-core machines with with up to 550 distributed systems
low-clocked cores are unsuitable for WinCC OA). As for RAM, CPU and 5)
HDD, the usual rule applies: more is better Physical limit: < 244 clients per server, recommended: max. 100 clients per
2)
server
System requirements generally only refer to WinCC OA Version 3.14 under
the supported versions of the Windows and Linux operating systems.
3)
A precondition for the minimum requirement is that the operating system
used does not have any greater requirements itself
4)
With a large system it is essential that the system permits not only the
highest data point numbers but also a high dynamic response.

WinCC OA is ideally suited for use in very large distributed


systems. The optimum design of such systems demands
corresponding system knowledge of WinCC OA. Due to the
event-oriented processing, individual design parameters can be
increased or reduced as necessary in actual applications.

Siemens ST 80 / ST PC 2016 3/147


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.

SIMATIC SIMATIC
WinCC Open Architecture WinCC Open Architecture
system software V3.14 system software V3.14
WinCC OA core components WinCC OA Server
WinCC OA Server
WinCC OA Server unlimited V3.14 6AV6351-1HP31-4AA0
Language/script versions: De, En;
with license for: License for server (without operator
station licenses), with unlimited I/O,
WinCC OA single-user station 6AV6351-1HA31-4AA0 alerting, extended trend, historical
500 I/O V3.14 recording, S7 driver,
License for single operator station SSL encryption, OPC client,
with up to 500 I/O (bit, integer), OPC server, OPC UA client,
alerting, extended trend, WinCC OA Web server and one
historical recording, S7 driver, WinCC OA OPERATOR 1 Device
SSL encryption, OPC client, License
OPC server, OPC UA client, WinCC OA dongle V3.14 6AV6351-1AH31-4AA0
WinCC OA Web server and one
WinCC OA OPERATOR 1 Device Hardware dongle for USB port for

3
License. Cannot be expanded with operation with a hardware-indepen-
multiple operator stations or dent license attached to the dongle,
add-ons. which can also extend the
hardware-linked license of the
WinCC OA Server I/O V3.14 operator station or server on a
License for server (without operator temporary basis.
station licenses), alerting, WinCC OA on data medium 6AV6351-1AX31-4AA0
extended trend, historical
recording, S7 driver, WinCC OA Software DVD current
SSL encryption, OPC client, version on disk
OPC server, OPC UA client, WinCC OA for Nanobox 128 I/O 6AV6351-1KA31-4AA0
WinCC OA Web server and one
Runtime License for SIMATIC
WinCC OA OPERATOR 1 Device
Nanobox (Win 7 Ultimate SP1
License 64-bit) with max. 128 I/O, including
WinCC OA Server 1,000 I/O 6AV6351-1HB31-4AA0 one operator station, distributed
V3.14 With a max. of 1,000 I/O systems option, S7 driver,
of any type SSL encryption, OPC client,
WinCC OA Server 3,000 I/O 6AV6351-1HC31-4AA0 OPC server, OPC UA client,
V3.14 With a max. of 3,000 I/O RDB option, WinCC OA Web server
of any type as well as a choice of one other
WinCC OA Server 5,000 I/O 6AV6351-1HD31-4AA0 driver. This package cannot be
V3.14 With a max. of 5,000 I/O expanded with other WinCC OA
of any type options. The use of this license is
WinCC OA Server 10,000 I/O 6AV6351-1HE31-4AA0 exclusively restricted to the
V3.14 With a max. of 10,000 I/O approved Nanoboxes (restrictions
of any type on the hardware side can be
viewed in the online help).
WinCC OA Server 15,000 I/O 6AV6351-1HF31-4AA0
V3.14 With a max. of 15,000 I/O WinCC OA for Nanobox 512 I/O 6AV6351-1KB31-4AA0
of any type Runtime License for SIMATIC
WinCC OA Server 25,000 I/O 6AV6351-1HG31-4AA0 Nanobox (Win 7 Ultimate SP1
V3.14 With a max. of 25,000 I/O 64-bit) with max. 512 I/O, including
of any type 1 user interface, one operator
WinCC OA Server 50,000 I/O 6AV6351-1HH31-4AA0 station, distributed systems option,
V3.14 With a max. of 50,000 I/O S7 driver, SSL encryption,
of any type OPC client, OPC server,
WinCC OA Server 75,000 I/O 6AV6351-1HJ31-4AA0 OPC UA client, RDB option,
V3.14 With a max. of 75,000 I/O WinCC OA Web server as well as a
of any type choice of one other driver, and
HTTP server.
WinCC OA Server 100,000 I/O 6AV6351-1HK31-4AA0 This package cannot be expanded
V3.14 With a max. of 100,000 I/O with other WinCC OA options.
of any type Further options and drivers are
WinCC OA Server 150,000 I/O 6AV6351-1HL31-4AA0 available. The use of this license is
V3.14 With a max. of 150,000 I/O exclusively restricted to the
of any type approved Nanoboxes (restrictions
WinCC OA Server 200,000 I/O 6AV6351-1HM31-4AA0 on the hardware side can be
V3.14 With a max. of 200,000 I/O viewed in the online help).
of any type
WinCC OA Server 250,000 I/O 6AV6351-1HN31-4AA0
V3.14 With a max. of 250,000 I/O
of any type

3/148 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.


SIMATIC SIMATIC
WinCC Open Architecture WinCC Open Architecture
system software V3.14 system software V3.14
WinCC OA for Nanobox 2 048 I/O 6AV6351-1KC31-4AA0 WinCC OA Client
Runtime License for SIMATIC WinCC OA 1 Client V3.14 6AV6351-1CP31-4AA0
Nanobox (Win 7 Ultimate SP1
64-bit) with max. 2 048 I/O, Operator station license with all
including 1 user interface, one server operator station
operator station, distributed functionalities.
systems option, S7 driver, The client license can be installed
SSL encryption, OPC client, on more than one PC only the
OPC server, OPC UA client, number of simultaneously active
RDB option, WinCC OA Web server clients is counted.
as well as a choice of one other WinCC OA 10 Client V3.14 6AV6351-1CQ31-4AA0
driver, and HTTP server. 10 operator station licenses with all
This package cannot be expanded server operator station functional-
with other WinCC OA options. ities. Client licenses can be
Further options and drivers are installed on multiple PCs - only the

3
available. The use of this license is number of simultaneously active
exclusively restricted to the clients is counted.
approved Nanoboxes (restrictions
on the hardware side can be WinCC OA 25 Client V3.14 6AV6351-1CR31-4AA0
viewed in the online help). 25 operator station licenses with all
WinCC OA for Nanobox 4 096 I/O 6AV6351-1KE31-4AA0 server operator station functional-
ities. Client licenses can be
Runtime License for SIMATIC installed on multiple PCs - only the
Nanobox (Win 7 Ultimate SP1 number of simultaneously active
64-bit) with max. 4 096 I/O, clients is counted.
including one operator station,
distributed systems option, S7 WinCC OA 50 Client V3.14 6AV6351-1CS31-4AA0
driver, SSL encryption, OPC client, 50 operator station licenses with all
OPC server, OPC UA client, server operator station functional-
RDB option, WinCC OA Web server ities. Client licenses can be
as well as a choice of one other installed on multiple PCs - only the
driver. This package cannot be number of simultaneously active
expanded with other WinCC OA clients is counted.
options. The use of this license is
exclusively restricted to the WinCC OA 100 Client V3.14 6AV6351-1CT31-4AA0
approved Nanoboxes. (Hardware 100 operator station licenses with
restrictions can be found in the all server operator station function-
online help.) alities. Client licenses can be
installed on multiple PCs - only the
number of simultaneously active
clients is counted.

Siemens ST 80 / ST PC 2016 3/149


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.


SIMATIC SIMATIC
WinCC Open Architecture WinCC Open Architecture
system software V3.14 system software V3.14
WinCC OA WebClient V3.14 WinCC OA Ultralight UX PC Client
The WebClient enables the The Ultralight UX PC Client enables
visualization and operation of an operator terminal to be imple-
process pictures over an exclu- mented in a web browser without
sively HTTP connection between installation of a plug-in. The
the server and the web client. The Ultralight UX PC Client can run on
WebClient can be installed remotely PCs and laptops. Only the number
on Windows and Linux computers. of simultaneously active Ultralight
Administrator rights are required for UX PC Clients is counted. Supports
installing under Windows. Plant a subset of the standard client func-
displays are now only available on tionality. Please note Ultralight UX
the WinCC OA Server. Please note Client restrictions according to the
WebClient restrictions according to online help.
the online help.
WinCC OA 1 Ultralight UX PC 6AV6351-1JK31-4AA0
WinCC OA 1 WebClient V3.14 6AV6351-1DP31-4AA0 Client
3 Web client license for WinCC OA
Server. Only the number of
License for 1 Ultralight UX PC Client
running on a laptop or PC.
simultaneously active web clients is
counted. WinCC OA 10 Ultralight UX PC 6AV6351-1JL31-4AA0
Client
WinCC OA 10 WebClient V3.14 6AV6351-1DQ31-4AA0 License for 10 Ultralight UX PC
10 WebClient licenses for WinCC Clients running on laptops or PCs.
OA Server. Only the number of
simultaneously active WebClients is WinCC OA 25 Ultralight UX PC 6AV6351-1JM31-4AA0
counted. Client
License for 25 Ultralight UX PC
WinCC OA 25 WebClient V3.14 6AV6351-1DR31-4AA0 Clients running on laptops or PCs.
25 WebClient licenses for WinCC
OA Server. Only the number of WinCC OA 50 Ultralight UX PC 6AV6351-1JN31-4AA0
simultaneously active WebClients is Client
counted. License for 50 Ultralight UX PC
Clients running on laptops or PCs.
WinCC OA 50 WebClient V3.14 6AV6351-1DS31-4AA0
50 WebClient licenses for WinCC WinCC OA 100 Ultralight UX PC 6AV6351-1JP31-4AA0
OA Server. Only the number of Client
simultaneously active WebClients is License for 100 Ultralight UX PC
counted. Clients running on laptops or PCs.
WinCC OA 100 WebClient V3.14 6AV6351-1DT31-4AA0
100 WebClient licenses for WinCC
OA Server. Only the number of
simultaneously active WebClients is
counted.

3/150 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.


SIMATIC SIMATIC
WinCC Open Architecture WinCC Open Architecture
system software V3.14 system software V3.14
WinCC OA Mobile Client WinCC OA parameter assignment
The Mobile Client enables an and development license
operator panel to be implemented WinCC OA Para for single-user 6AV6351-1EA31-4AA0
on a mobile device. Installation station V3.14
takes place via an app available in
the iTunes App Store or in Google Client, parameterization and
Play Store. Only the number of development license for single
simultaneously active Mobile operator station, graphic editor with
Clients is counted. You can find the symbol catalog, user-friendly script
supported Android and iOS development language, alerting,
systems and restrictions in the extended trend, and historical
online help. recording. Requires a correspond-
ing single-user station license.
WinCC OA 1 Mobile Client 6AV6351-1JQ31-4AA0
WinCC OA Para V3.14 6AV6351-1EP31-4AA0
License for 1 WinCC OA Mobile
Client, parameterization and

3
Client for iOS or Android
development license for server,
WinCC OA 10 Mobile Client 6AV6351-1JR31-4AA0 graphic editor with symbol catalog,
License for 10 WinCC OA Mobile user-friendly script development
Clients for iOS or Android language, alerting, extended trend,
and historical recording. Requires
WinCC OA 25 Mobile Client 6AV6351-1JS31-4AA0 corresponding server license.
License for 25 WinCC OA Mobile
Clients for iOS or Android WinCC OA Para Remote V3.14 6AV6351-1EQ31-4AA0
Client, parameterization and
WinCC OA 50 Mobile Client 6AV6351-1JT31-4AA0 development license for remote
License for 50 WinCC OA Mobile access to server including graphic
Clients for iOS or Android editor with symbol catalog, user-
friendly script development
WinCC OA 100 Mobile Client 6AV6351-1JU31-4AA0 language, alerting, extended trend,
License for 100 WinCC OA Mobile and historical recording.
Clients for iOS or Android
WinCC OA API interface gen. 6AV6351-1EK31-4AA0
WinCC OA OPERATOR V3.14
mobile app Application programming interface
Permits operation and visualization for the integration of customer-
of a WinCC OA installation via specific managers or drivers. One
iPhone and iPad. Over a secured license is required for each
SSL connection, measured values development workstation. We
and alarms can be retrieved, as strongly recommend the participa-
well as commands and acknowl- tion in a Certified WinCC OA
edgements sent. Navigation takes Developer Workshop when ordering
place in list form or map-supported. this product for the first time.
The configuration is carried out in
an intuitive wizard. Each device WinCC OA Custom Driver V3.14 6AV6351-1EL31-4AA0
must be assigned its own, fixed Extends a WinCC OA server license
license. with the option of communication
with a customer-specific driver. One
WinCC OA OPERATOR 1 device 6AV6352-1DK31-4AA0 license is required for each
License for 1 device customer-specific driver.

WinCC OA OPERATOR 3 devices 6AV6352-1DL31-4AA0 WinCC OA Custom Manager 6AV6351-1EM31-4AA0


V3.14
License for 3 devices
Extends a WinCC OA server license
WinCC OA OPERATOR 6AV6352-1DM31-4AA0 with the option of communicating
10 devices with a customer-specific manager.
One license is required for each
License for 10 devices customer-specific manager
WinCC OA OPERATOR 6AV6352-1DN31-4AA0
25 devices
License for 25 devices

WinCC OA OPERATOR 6AV6352-1DP31-4AA0


50 devices
License for 50 devices

Siemens ST 80 / ST PC 2016 3/151


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.


SIMATIC SIMATIC
WinCC Open Architecture WinCC Open Architecture V3.14
system software V3.14 communication
WinCC OA redundancy WinCC OA TLS driver 6AV6352-1BA31-4AA0
In the case of redundant servers, Driver in accordance with TLS
two server licenses and two regulations via TCP/IP, serial in
WinCC OA redundancy options are conjunction with Siemens
required for each redundant server Commbox (see separate data
pair. sheet).
WinCC OA redundancy V3.14 6AV6351-1FP31-4AA0 WinCC OA Teleperm M 6AV6352-1BB31-4AA0
Extends a WinCC OA Server with Driver for Teleperm M Bus C275
the option of bumpless switchover (requires an Ako-Tec Bridge)
to a hot standby server.
WinCC OA S7 TCP/IP driver 6AV6352-1BC31-4AA0
WinCC OA distributed systems TCP/IP driver for Siemens Industrial
Enables the connection of several Ethernet. Included in the WinCC OA
autonomous WinCC OA systems. Server.
Each server requires one server
3 license and one distributed systems
option. In the case of redundant
WinCC OA Modbus TCP/IP driver
Driver for Modbus TCP/IP
6AV6352-1BD31-4AA0

servers, 2 licenses are required for


the redundant server pair. WinCC OA Ethernet/IP 6AV6352-1CK31-4AA0
Driver for Allen Bradley - Rockwell
WinCC OA distributed systems 6AV6351-1GP31-4AA0
EtherNet/IP
V3.14
Extends a WinCC OA Server to WinCC OA SAIA S-Bus 6AV6352-1BW31-4AA0
include the Multiserver option. Driver for SAIA controllers
(SAIA S bus)
WinCC OA Disaster Recovery
System WinCC OA SSI driver 6AV6352-1BF31-4AA0
WinCC OA Disaster Recovery 6AV6352-1AA31-4AA0 Driver for SAT telecontrol
Center V3.14 components
Allows configuration of a remote WinCC OA SNMP 6AV6352-1BG31-4AA0
backup control center. A disaster Driver SNMP network monitoring
recovery center comprises two (V2&V3)
distributed systems. Both systems
must be redundant. Requires WinCC OA BACnet Driver + 6AV6352-1DA31-4AA0
Oracle databases and RDB. Refer Diagnostics
to the online help for example Extends a WinCC OA Server to
configurations. Each server in the include a license for using the
Disaster Recovery System requires WinCC OA BACnet online
one WinCC OA Disaster Recovery engineering environment consisting
Center option. of WinCC OA BACnet driver,
WinCC OA BACnet object library
including faceplates, and
WinCC OA BACnet browser
(max. 5 000 objects per server).
WinCC OA IEC 104 6AV6352-1BH31-4AA0
Driver IEC 60870-5-104

WinCC OA IEC 101 6AV6352-1BJ31-4AA0


Driver IEC 60870-5-101

3/152 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture V3.14

Ordering data Article No. Article No.


SIMATIC SIMATIC
WinCC Open Architecture V3.14 WinCC Open Architecture V3.14
communication communication
WinCC OA IEC 61850/61400 6AV6352-1BV31-4AA0 WinCC OA SINAUT unlimited 6AV6352-1BU31-4AA0
Expands a WinCC OA Server with a SINAUT driver unlimited license
license for using the IEC 61850
protocol comprising the IEC 61850 WinCC OA RK512 6AV6352-1CA31-4AA0
driver (client in accordance with Driver for connection via
IEC 61850 Standard Part 7 & Part 8 3964R / RK512 protocol
Edition 2 & IEC 61400-25) and the
IEC 61850 browser. WinCC OA Cerberus 6AV6352-1CH31-4AA0
Driver for connection with the
WinCC OA DNP3 10 devices 6AV6352-1BK31-4AA0
Siemens DMS7000 / Cerberus fire
Driver DNP3 for connecting up to alarm system. Communication is
10 DNP3 devices implemented via the C-Bus
WinCC OA DNP3 25 devices 6AV6352-1BL31-4AA0 (Cer-Ban) using the serial interface
RS 232 (MK 7022).
Driver DNP3 for connecting up to
25 DNP3 devices WinCC OA OPC HDA server 6AV6352-1CL31-4AA0
WinCC OA DNP3 50 devices
Driver DNP3 for connecting up to
6AV6352-1BM31-4AA0 The WinCC OA OPC Historical Data
Access (HDA) Server provides
3
archived process data from a
50 DNP3 devices WinCC OA project.
WinCC OA DNP3 250 devices 6AV6352-1BN31-4AA0 (Status version: "OPC HDA 1.20"
Driver DNP3 for connecting up to (mandatory functions))
250 DNP3 devices WinCC OA OPC HDA Client 6AV6352-1CM31-4AA0
WinCC OA DNP3 unlimited 6AV6352-1BP31-4AA0 The WinCC OA OPC Historical Data
Driver DNP3 unlimited license Access (HDA) Client allows access
to the process data provided by
WinCC OA SINAUT 10 devices 6AV6352-1BQ31-4AA0 any OPC HDA Servers
(Version: "OPC HDA 1.20"
SINAUT driver for connecting up to (mandatory functions))
10 controllers
WinCC OA OPC UA Server 6AV6352-1CJ31-4AA0
WinCC OA SINAUT 25 devices 6AV6352-1BR31-4AA0
Driver for OPC UA DA and
SINAUT driver for connecting up to OPC UA AC Server
25 controllers (SBK Bundle 1.3.3)
WinCC OA SINAUT 50 devices 6AV6352-1BS31-4AA0
SINAUT driver for connecting up to
50 controllers
WinCC OA SINAUT 250 devices 6AV6352-1BT31-4AA0
SINAUT driver for connecting up to
250 controllers

More information
Further information can be found in the Internet at:
http://www.siemens.com/wincc-open-architecture

Siemens ST 80 / ST PC 2016 3/153


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Overview
SIMATIC WinCC Open Architecture is a SCADA system for Current version: SIMATIC WinCC Open Architecture V3.14
visualizing and operating processes, production flows, runs under:
machines and plants in all industrial sectors. Windows 10 (64-bit)/Windows 8.1 Enterprise/Professional
SIMATIC WinCC OA is built consistently on object-oriented (64-bit)
structures. Due to this consistent and well-considered use of Windows 7 Ultimate/Enterprise/Professional SP1 (64-bit)
object-oriented structures, from process images to the data- Windows Embedded Standard 7 (64-bit)
base, the engineering costs improve for SIMATIC WinCC OA (released for IPC 227E / 277E only)
customers.
Windows Server 2012 R2 (64-bit)
Distributed systems enable the connection of up to
2 048 autonomous SIMATIC WinCC Open Architecture systems Windows Server 2008 R2 (64-bit)
via a single network. Each subsystem can be configured either Red Hat Enterprise Linux 7.1 (64-bit)
as single-user or multi-user system, each of which may be OpenSUSE 13.2 (64-bit)
redundant or non-redundant.
CentOS 7.1 (64-bit)
VMWare ESXi Version 6
3 Note:
Native 64-bit support.

Function
SIMATIC WinCC Open Architecture add-ons
The universal WinCC Open Architecture basic software is the
basis for modular expansions. These functional expansions are
available in the form of WinCC Open Architecture add-ons.

Field devices or other


MODBUS (TCP)
connected systems

WinCC OA
server (multi-user system)
OPC UA (TCP)
WinCC OA
server
(stand-alone
system)

system 3 operator station operator station system 2

WinCC OA
System communication TCP
system 1

operator station
S7 Industrial Ethernet (TCP)

WinCC OA
server (redundant)
operator station
G_ST80_XX_00480

operator station

Distributed systems with WinCC OA

3/154 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Function (continued)
Add-ons Task Add-ons Task
BACnet BACnet provides an integrated BACnet-compliant Communication Stands for modern alarm management/remote
online/offline engineering solution for building Center alerting and communication using the latest
automation technology, including object library. standards and various media. The Communication
Designed for heating, ventilation and Center creates synergies by using the various inter-
air-conditioning, lighting control and safety systems. faces for remote alerting via the control system.
Text message and email media are covered with the
S7 AdvancedLib The S7 AdvancedLib (AdvS7) is an industry-inde- Communication Center.
object library pendent object library that permits the use and
visualization of objects from the process control VIDEO Enables the integration of a video management
system (e.g.: drives, valves, regulators, motors, (see figure below) system in WinCC OA. Through the combination of
etc.) in a project with WinCC OA and S7. In addition SCADA and video monitoring in one system, the
to the WinCC OA and AdvS7 license, the use of costs for separate video interfaces and the addi-
S7 AdvancedLib requires the use of the relevant tional expense of maintenance and operation can
library on the SIMATIC side. be saved, and the period of training for operating
personnel can also be reduced.
Maintenance package Includes the following functions: Operating hours
counter, operating cycle counter and maintenance HTTP server For displaying WinCC OA data via Intranet and
log. Web.
Scheduler Permits the creation, parameterization and
management of time programs that allow the time
Authentication via
Kerberos
A WinCC OA system can be exposed to a variety of
attacks. An unauthorized WinCC OA System could 3
and event-driven triggering of specific actions. set up a connection to the distribution manager or
hackers could try to manipulate WinCC OA
Recipes WinCC OA recipes allow setpoints or commands for messages. Secure authentication has been devel-
certain data point elements to be sent simultane- oped to prevent such attacks. The authentication
ously. Based on "recipe types", which define the based on Kerberos enables each WinCC OA com-
quantity of the assigned data point elements, ponent to verify the identity of another component.
recipes are created that send their values to the WinCC OA servers can verify the identity of the cli-
data point elements upon activation. ents and clients can verify the identity of the serv-
GIS Viewer With the help of this viewer, standardized cards of a ers. In addition, Kerberos ensures that messages
geo-information system (GIS) can be fully are not modified during their transmission (capture-
integrated in WinCC OA. Furthermore, it is possible replay attacks are prevented). Furthermore, it is also
to display all WinCC OA objects in the cards. possible to send messages in encrypted form.
Reporting Web-based reporting is implemented using the AMS (Advanced For the effective planning, administration, imple-
standardized Simple Object Access Protocol Maintenance Suite) mentation and monitoring of maintenance work and
(SOAP) reporting interface. Reporting tools from faults. The processes are evaluated by means of
third-party suppliers can thus be used with no statistics and reports are communicated.
additional effort. The BIRT templates that are also Web client From a technical standpoint, the WinCC OA Web
provided, as well as the predefined reporting data, Client is a plug-in that is downloaded via the web
further simplify the reporting. browser (which is used on the client computer) and
Web-capable reporting interface (SOAP): a WinCC OA UI Manager is then displayed embed-
- ECLIPSE BIRT (large number of reporting ded in the HTML page. No WinCC OA installation on
templates for ECLIPSE BIRT are also supplied) the client computer is required, except for the
- Crystal Reports required web client plug-ins.
- SIMATIC Information Server
- Microsoft Excel Ultralight Client UX A "thin client" that is suitable for plant access via a
Online values, history PC workstation and a browser. Access is possible
Support of compressed data, SQL, alarms via a standard Web browser without the need for
Diagnostic tools any additional installations.
Audit trail
WinCC OA Permits operation and visualization of a WinCC OA
Excel report Powerful report generator directly in Microsoft OPERATOR installation via iPhone and iPad. Process data, plant
Excel. Templates can be created easily and directly availability, and plant status can all be displayed.
in Excel. If a report has to be created over a defined Location filtering provides a rapid overview of all
period of time, the system accesses the template spatially distributed systems including summation
and automatically completes it with data from the alarms.
WinCC OA process database. Reports can also be
created, printed and saved on a time-controlled Disaster Recovery This system expands the simple redundancy to
basis, without any need for user access. The Excel System include a second redundant system, to which the
Report fully supports compression structures (see figure below) system can switch over in the event of a fault (e.g.
(AC - archive compression) of WinCC OA. fire or explosion in the building of the primary sys-
tem). By means of this additional local redundancy,
the highest level of system stability is obtained.

Siemens ST 80 / ST PC 2016 3/155


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Function (continued)
Video workstation
Monitor 1

control panel
mouse
keyboard video monitor 1
joystick

control monitor video monitor 2


(optional) (optional)

3
encoder
TCP/IP Control commands
connection Cameras or
decoder crossbars

network
video recorder

G_ST80_XX_00481
WInCC OA
server

Control of monitor wall via POSA protocol Monitor wall


(monitors 2 ... n)

Network topology Video

Primary server system (PSS) Secondary server system (SSS)

data base in data base in


Oracle cluster Oracle cluster

WinCC OA WinCC OA
hot-standby hot-standby
active system passive active system passive
server (A) server (B) server (A) server (B)
G_ST80_XX_00482

Operating interface with Field device or other


one or two connected systems
interfaces e.g. OPC UA

Disaster Recovery System architecture with WinCC OA

3/156 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Ordering data Article No. Article No.

SIMATIC WinCC SIMATIC WinCC


Open Architecture add-ons Open Architecture add-ons
WinCC OA BACnet driver + 6AV6352-1DA31-4AA0 WinCC OA DB Logger 6AV6352-1DJ31-4AA0
diagnostics The WinCC OA DB Logger permits
Extends a WinCC OA Server to the export of freely selectable data
include a license for using the from WinCC OA to an external data-
WinCC OA BACnet online base. See the online help for further
engineering environment consisting information.
of WinCC OA BACnet driver, WinCC
OA BACnet object library including Solution Frameworks
faceplates, and WinCC OA BACnet The Solution Frameworks are only
browser (max. 5 000 objects per available in combination with
server). consulting and additional testing
overhead, and not as standard
WinCC OA BACnet Engineering 6AV6352-1DB31-4AA0 products.
Extends a WinCC OA Server to
include a license for using the WinCC OA PMS 6AV6352-1EA31-4AA0
WinCC OA BACnet engineering Application framework for the

3
environment consisting of WinCC implementation of production
OA BACnet browser, WinCC OA management systems. The frame-
EDE-Tool + EDE file interface work offers functions for recording
(requires the WinCC OA and evaluating production and
engineering license) batch-related quality data. This item
(max. 5 000 objects per server). is not available as a product but
only in combination with consulting
WinCC OA GIS 6AV6352-1DC31-4AA0 and additional testing overhead.
GIS viewer for displaying ESRI
Shapes Files. One license is WinCC OA topology package 6AV6352-1EB31-4AA0
required for each UI. Can be used The topology package is an
in WinCC OA Client and Web Client. application framework enabling the
Maps are not included. topological coloring of network
Dynamization performed using views. A qualitative statement is
Ctrl scripting. made regarding which parts of a
network are directly connected to
WinCC OA S7 AdvancedLib 6AV6352-1DD31-4AA0 which infeed units in a connection
Runtime license for using the object established by switching elements.
library WinCC OA S7 AdvancedLib, Only available in combination with
coordinated with the SIMATIC consulting and additional testing
object library also supplied, which overhead.
is free of charge until revoked.
License required for each server. WinCC OA ACAS 6AV6352-1EC31-4AA0
The PLC section of this library is the WinCC OA Advanced Command
intellectual property of Siemens AG Authority Suite framework for
- a software sublicense contract to managing and visualizing authority
this effect must be signed and settings. The license includes the
returned before the SIMATIC Object management panel and panel
Library can be obtained. expansions for alarm, horn and
acknowledgement functions. This
WinCC OA Maintenance 6AV6352-1DE31-4AA0 item is not available as a sole
Maintenance management for product, only in combination with
recording operating hours, consulting and additional testing
switching cycles, alarm handling overhead.
and notepad function. License
required for each server. WinCC OA APM 6AV6352-1ED31-4AA0

WinCC OA Scheduler 6AV6352-1DF31-4AA0 The WinCC OA Framework APM


Advanced Playback Manager
Daily, weekly and monthly program, allows you to play back the system
as well as individual non-periodic status of the real-time system in a
events with consideration of public test/simulation system. The APM
holidays, assignment of priority and offers the following functions: Snap-
override function. License required shot (moment in time), playback
for each server. (time range), training sequence.
WinCC OA Recipe 6AV6352-1DG31-4AA0 Please note that the APM Package
Creation of any recipe types and does not include any simulation of
recipes, acceptance of current the process or of the associated
process values as recipe, activa- open loop control. Since APM is a
tion/download to data points, import framework, we urgently recommend
and export (Microsoft Excel). that you use our Consulting Service
License required for each server. for project-specific integration.

WinCC OA RDB 6AV6352-1DH31-4AA0


RDB Oracle connection for
WinCC OA Server. Oracle licenses
are not included. License required
for each server. (RDB for CentOS
and OpenSuse are not supported).

Siemens ST 80 / ST PC 2016 3/157


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Ordering data Article No. Article No.


SIMATIC WinCC SIMATIC WinCC
Open Architecture add-ons Open Architecture add-ons
Reporting Video management
Expands a WinCC OA Server to Permits the display of video
include a reporting interface for streams in the client UI and Web cli-
active connections (clients) for the ent, as well as the control of video
evaluation of WinCC OA data by equipment (swivel cameras, record-
means of a third-party tool such as ers, ). More detailed information
BIRT, Crystal Reports or MS Excel. and details of supported hardware
(In WinCC OA Version 3.14, the can be obtained from the online
existing Excel Report is still help. Streams are parallel, actively
supported and is automatically displayed external or displayed
supplied along with the WinCC OA recorded video signals. Necessary
Reporting option.) Licenses for WinCC OA Server licenses require
third-party tools are not supplied. no additional I/Os. Two licenses are
required for one redundant server
WinCC OA Reporting 1 client 6AV6352-1FE31-4AA0 pair.
Expands a WinCC OA Server to

3 include a reporting client. WinCC OA Video Light 6AV6352-1JA31-4AA0


Permits connection of 16 video
WinCC OA Reporting 2 clients 6AV6352-1FF31-4AA0 inputs (cameras) and simultaneous
Expands a WinCC OA Server to display of 4 video outputs
include 2 reporting clients. (streams). This package cannot be
WinCC OA Reporting 5 clients 6AV6352-1FG31-4AA0 expanded.
Expands a WinCC OA Server to WinCC OA Video Basic 6AV6352-1JB31-4AA0
include 5 reporting clients. Permits connection of 32 video
WinCC OA Reporting 10 clients 6AV6352-1FH31-4AA0 inputs (cameras) and simultaneous
display of 8 video outputs
Expands a WinCC OA Server to (streams). An expansion with addi-
include 10 reporting clients. tional video inputs and outputs is
Communication Center possible, as well as video recording
and video export functions.
WinCC OA CommCenter 1 6AV6352-1GA31-4AA0
WinCC OA Video Inputs 6AV6 352-1JD31-4AA0
Basic package for 25 alarms.
Output as text message or e-mail is WinCC OA Video Inputs expand the
possible. Price per WinCC OA WinCC OA Video Package Basic by
Server. 8 additional video inputs (cameras)

WinCC OA CommCenter 2 6AV6352-1GB31-4AA0 WinCC OA Video Output 6AV6 352-1JE31-4AA0


Basic package for 250 alarms. WinCC OA Video Outputs expand
Output as text message or e-mail is the WinCC OA Video Package
possible. Price per WinCC OA Basic by 1 additional video output
Server. (stream)
WinCC OA CommCenter 3 6AV6352-1GC31-4AA0 WinCC OA Video Recording 6AV6352-1JF31-4AA0
Basic package for 2 500 alarms.
WinCC OA Video Recording
Output as text message or e-mail is
expands a WinCC OA Video Basic
possible. Price per WinCC OA
Package by 8 streams that can be
Server.
recorded on hard disk.
WinCC OA CommCenter 4 6AV6352-1GD31-4AA0
WinCC OA Video Export 6AV6352-1JG31-4AA0
Basic package for unlimited alarms.
Output as text message or e-mail is WinCC OA Video Export expands a
possible. Price per WinCC OA WinCC OA Video Basic Package
Server. with one Video Export operator
station.

3/158 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

Ordering data Article No. Article No.


SIMATIC WinCC SIMATIC WinCC
Open Architecture add-ons Open Architecture add-ons
HTTP Server AMS Large 5,000 A/E 6AV6352-1ME31-4AA0
The HTTP server contains only the The license includes the
license for the HTTP server. HTTP AMS application as well as up to
clients represent interrupts, events 5,000 A/E = 5,000 checklists
and other WinCC OA information on assigned to alarm/event DP. 1)2)3)
HTML pages. The pages can be AMS Upgrade Large 6AV6352-1MF31-4AA0
created in corresponding external
tools. Simple example pages are The license contains an upgrade of
also supplied. the AMS Large 5,000 A/E license
with 1,000 A/E = 1,000 checklists
WinCC OA Web Server 6AV6351-1JV31-4AA0 assigned to alarm/event DP.
Enables the management of AMS UL A/E 6AV6352-1MG31-4AA0
different connections and resources
between the WinCC OA Server and The license includes the
the WinCC OA Ultralight UX PC AMS application as well as an
Clients. The Load Balancing feature unlimited number of alarm/event DP
checklist assignments. 1)2)3)
3
can be activated with a number
greater than 1. This feature distrib- AMS Client 2 UI 6AV6352-1MH31-4AA0
utes the load of multiple clients
Operating station license for
evenly across the different Web
simultaneous use of no more than
servers, thus allowing it to be
2 parallel client sessions. The client
scaled. With remote Web servers,
license can be installed on more
multilevel architectures such as
than one PC only the number of
access to DMZs (demilitarized
simultaneously active clients is
zones) can be implemented.
counted.
Kerberos
AMS Client 5 UI 6AV6352-1MJ31-4AA0
WinCC OA Secure 6AV6352-1LA31-4AA0 Operating station license for
Extends a WinCC OA Server to simultaneous use of no more than
include protection by Kerberos. 5 parallel client sessions. The client
Each WinCC OA Server requires a license can be installed on more
separate WinCC OA Secure than one PC only the number of
license. simultaneously active clients is
counted.
AMS
(Advanced Maintenance Suite) AMS Client 10 UI 6AV6352-1MK31-4AA0
Operating station license for
AMS Starter Package 20A/E 6AV6352-1MA31-4AA0
simultaneous use of no more than
This fully functional trial license 10 parallel client sessions. The
valid for 90 days includes the AMS client license can be installed on
application as well as up to 20 A/E more than one PC only the
= 20 checklists assigned to alarm/ number of simultaneously active
event DP. 1)2)3) clients is counted.
AMS Entry 20 A/E 6AV6352-1MB31-4AA0
The license includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP. 1)2)3)
AMS Small 100 A/E 6AV6352-1MC31-4AA0
The license includes the
AMS application as well as up to
100 A/E = 100 checklists assigned 1) The basic price also includes the AMS Reports packages.
to alarm/event DP. 1)2)3) 2) AMS importer as well as 1 day of consulting for initial design by ETM
AMS Medium 1,000 A/E 6AV6352-1MD31-4AA0 Consultants (excluding travel expenses) and 5 hours of telephone support
The license includes the within 3 months after delivery.
3) AMS Reports and AMS Importer, and 1 day of consulting for initial concep-
AMS application as well as up to
1,000 A/E = 1,000 checklists tualization by ETM consultants (not incl. travel costs). This license does not
assigned to alarm/event DP. 1)2)3) include any support and cannot be expanded or extended.

More information
Additional information is available on the Internet at:
http://www.siemens.com/wincc-open-architecture

Siemens ST 80 / ST PC 2016 3/159


Siemens AG 2016

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

Overview Benefits
SIMATIC ProAgent Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
The software options package for fast, targeted process fault reduces the lifecycle costs
diagnosis that ProAgent:
provides plant and machine personnel with optimized support - Provides optimum support for plant and machine personnel
with troubleshooting and fault rectification, in respect of troubleshooting and fault rectification
increases the plant availability, and - Increases plant availability
- Reduces downtimes
reduces downtimes.
No further configuration overhead for diagnostics functionality
Process error diagnosis software for quick and precise Frees up PLC capacity with regard to memory and program
diagnosis of faults/errors in plants and machines for execution time
SIMATIC S7 and SIMATIC HMI No special operator know-how is required thanks to clearly
Standardized diagnostics concept for various comprehensible indication of the cause of error
SIMATIC components:
optimum interaction of STEP 7 engineering tools and Application
3 SIMATIC HMI
Standardized user interface
Increased productivity is being achieved more and more by
cutting costs. In this context, the focus is increasingly on main-
tenance. The emphasis here is on rectifying faults as quickly and
efficiently as possible. Ideally, the operating personnel should
also perform part of the maintenance tasks. The operating per-
sonnel are on-site, they are familiar with the procedures and can
intervene quickly. This saves time and reduces costs. It is pre-
cisely here that ProAgent can assist operating personnel in iden-
tifying faults quickly, in particular in the automotive and machine
tool industries.
In the event of a process fault, process fault diagnosis with
SIMATIC ProAgent will provide information about the location
and cause of that fault and support personnel with trouble-
STEP 7 shooting.
The ProAgent solution has been optimized specifically for use
with SIMATIC S7-300/S7-400 and SIMATIC WinAC. It can be
used in combination with the S7-PDIAG, S7-GRAPH and
S7-HiGraph1) STEP 7 engineering tools. The ProAgent option
G_ST80_XX_00367

package features standard displays that are updated with


process-specific data during runtime.
1)
Process diagnostics with S7-HiGraph in combination with
TP/OP/MP 270/277, MP 370/377, and C7636 and PC RT systems.

Process error diagnostics with ProAgent for WinCC flexible/ProAgent and


with the STEP 7 engineering tools

STEP 7
G_ST80_XX_00581

WinCC/ProAgent Process error diagnostics

3/160 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

Function
Context-sensitive diagnostics initiation due to process error Message display
message
All of the existing process messages are shown in the message
Output of operands with symbols and comment display. Context-sensitive branching to other diagnostic dis-
Switching is possible between LAD, STL and signal list plays is also possible with a selected message. The operating
Supporting fault rectification with direct process access when personnel can also take the message directly from the erroneous
using the motion display operands and react immediately without having to perform any
other operations on the HMI device. WinCC flexible permits this
Output of the faulty operands directly in the message function on the Windows CE-based devices TP/OP/MP 270/277,
including address, symbol and comment1) MP 370/377, and on PC Runtime systems. The function is
Consistency test in RT: available as of version 6.0 for WinCC/ProAgent.
Inconsistent diagnostic units are marked with icons. This
permits quick locating of faults regarding configured data in
the commissioning phase.
Direct, unit-related entry point in the diagnostic display from
user displays by using ProAgent functions
Unit or message-related entry to STEP 7 (LAD/STL/FD editor,
S7-GRAPH, HW CONFIG (upon system error messages)), 3
supported fully automatically 2)
Unit or message-related entry to STEP 7), supported fully
automatically3)
Graphic display of step sequences (overview display)4)

1)
In combination with TP/OP/MP 270/277, MP 370/377, C7 636, WinCC/
ProAgent as of V6.0, and WinCC flexible/ProAgent
2)
WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007/ProAgent on PC
RT
3)
Only WinCC/ProAgent as of V5.5
4)
As of WinCC flexible 2007/ProAgent, WinCC/ProAgent as of V5.6 in combi-
nation with S7-GRAPH as of V5.1 (OCX is delivered as of S7-GRAPH 5.1)
Unit overview
Standardized user interface with standard displays The units overview displays all technological units and the
Message display respective sub-units (system/machine components) in table
form. In this display, the user is able to recognize, for example,
Unit overview which operating mode or which status the respective unit is in.
Diagnostics detail display The operating mode can be changed by the user if required.
Motion display Faulty units are marked with attributes.
Sequencer operating display
The displayed image contents are related to the previously
selected units or messages. This means that the proper. context-
sensitive diagnostics display can be called up based on a
message or a selected technological unit.

Siemens ST 80 / ST PC 2016 3/161


Siemens AG 2016

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

Function (continued)
Diagnostics detail display Sequencer operating display
The diagnostic detail display shows the faulty operands at the The sequencer operating display supports sequencer control.
time of origination of a process error. As an option, current status This makes functions such as initializing and acknowledging
information can also be displayed. The diagnostics results are sequencers, activating/deactivating individual steps and
either displayed in a ladder diagram (LAD), statement list (STL), operating mode settings possible analog to the status/control in
or in a clearly arranged signal list overview. The output of the S7-GRAPH. The steps are output to a list with step number/
operands depends on the display format with symbols and com- name. Attributes for identifying an active/faulty step give the
ments from the S7 symbol table. Only the operands that cause operating personnel an overview of the current status of the step
the fault are displayed and marked with a highlighted attribute. sequence.
Switching to a display that calls up the current status of all
operands in the controller is also possible.

Motion display Sequencer diagnostic display

The motion display is used for supported fault rectification. Every WinCC flexible /ProAgent and WinCC/ProAgent1) also offer
motion line contains a comment line that describes the motion capabilities for graphic monitoring and sequencer diagnostics.
(e.g. x-axis), two actions for implementing the motion, response This gives the user the ability to monitor active/faulty steps as
concerning the actuation of a motion and information on the well as the fault cause, e.g. faulty transition conditions,
respectively achieved end positions (max. 16). simultaneously on the HMI device.

The motion itself is controlled with softkeys on the side of 1)


WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1
SIMATIC Panels and Multi Panels. For time-critical motions, the (OCX is delivered as of S7-GRAPH 5.1)
actuation can be done directly through inputs of the controller
(depending on the capabilities of the target hardware:
24 V direct keys, DP direct keys via PROFIBUS).

3/162 Siemens ST 80 / ST PC 2016


Siemens AG 2016

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

Technical specifications
WinCC/ProAgent WinCC flexible /ProAgent
Interfaces
Can be used in conjunction with SIMATIC S7: SIMATIC S7:
programmable controllers: S7-300/S7-400; WinAC S7-300/S7-400; WinAC
Types of connection SIMATIC S7 Protocol Suite: SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP MPI, PROFIBUS DP,
PROFINET IO, Industrial Ethernet, TCP/IP
Display units
Standard images for: Standard displays for easy embedding in user displays,
example project for MP 377
Number of languages for 3 (de/en/fr) 5 (de/en/fr/it/es)
online language selection
Functionality
Modification of HMI diagnostics data WinCC/ProAgent V6.0 and higher No
management in RT
Unit overview Yes Yes 3
Message display Yes Yes
Sequencer operating display Yes Yes
Diagnostics detail display Yes Yes
Display Yes/Yes/Yes Yes/Yes/Yes
STL/LAD/signal list
Display of operands with symbol and Yes Yes
comment
Criteria analysis When fault occurs/current status/can be archived When fault occurs/current status
Motion display
Number of viewable movements 6 6
Directions of motion 2 2
Number of viewable end positions 16 16
per movement
Documentation
In electronic format de/en/fr; included in scope of delivery de/en/fr/it/es; included in scope of delivery
Requirements
HMI software WinCC V7.0 SP3 WinCC flexible 2008
(ProAgent V7.0 SP3)
Operating system: WinCC/ProAgent V7.0 + SP2: WinCC flexible / ProAgent 2008 + SP2:
Configuration Windows Professional SP3, Windows 7 (32-bit) Ultimate, Windows XP SP3,
Business, and Enterprise Windows 7 Professional,
Ultimate, Enterprise
Operating system WinCC/ProAgent V7.0 + SP2: WinCC flexible/ProAgent for SIMATIC Panels:
Runtime Windows XP Professional SP3, WinCC flexible / ProAgent for WinCC flexible Runtime:
Windows 7 (32-bit) Ultimate, Business and Enterprise, Windows XP SP3,
Windows 2003 Server SP2, Windows 2008 Server SP2 Windows 7 Professional, Ultimate, Enterprise
STEP 7 V5.4 SP4 and higher V5.3 and higher
S7-GRAPH V5.3 SP6 and higher V5.2 + SP3 and higher
S7-PDIAG V5.3 SP3 and higher V5.1 and higher
S7-HiGraph No V5.3 and higher
Type of delivery CD-ROM / Runtime license Runtime license
(one license is required for each
target hardware)

Siemens ST 80 / ST PC 2016 3/163


Siemens AG 2016

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

Ordering data Article No. Article No.

SIMATIC WinCC/ProAgent SIMATIC WinCC flexible /ProAgent


Software option package for Software option package for
process diagnosis based on process diagnostics based on
S7 GRAPH V5 and higher and S7 PDIAG V5.1 and higher,
S7 PDIAG V5 and higher; functional S7 GRAPH V5.2 + SP3 and higher;
enhancement for SIMATIC WinCC; S7 HiGRAPH V5.3 and higher.
electronic documentation in Functional enhancement for
English, French and German; SIMATIC WinCC flexible; electronic
functions and standard screens for documentation in English, French,
use on a PC (resolution German, Italian, and Spanish
1024 x 768 pixels) and WinCC flexible /ProAgent for 6AV6618-7DB01-3AB0
Panel PC 577/677/877 15" SIMATIC Panels
(resolution 1024 x 768 pixels) in Runtime license (Single License)
English, French and German, executable on TP/OP/MP 270/277,
runtime license (single license) Mobile Panel 277, and
WinCC version: MP 370/377
V7.4 1) 6AV6371-1DG07-4AX0 WinCC flexible /ProAgent for 6AV6618-7DD01-3AB0
WinCC flexible Runtime
V7.3 1) 6AV6371-1DG07-3AX0
3
Runtime license (single license)
as download
V7.4 1) 6AV6371-1HG07-4AX0
V7.3 1) 6AV6371-1HG07-3AX0
Upgrade
V7.x to V7.41) 6AV6371-1DG07-4AX3
V6.x to V7.3 1) 6AV6371-1DG07-3AX4
V7.x to V7.3 1) 6AV6371-1DG07-3AX3
as download
V7.x to V7.41) 6AV6371-1KG07-4AX3
V6.x to V7.3 1) 6AV6371-1KG07-3AX4
V7.x to V7.3 1) 6AV6371-1KG07-3AX3
1) Not multi-station-capable

3/164 Siemens ST 80 / ST PC 2016