Load Control Valves

Counterbalance, Vented Counterbalance and Motion Control Valve Packages for


applications up to 350 bar (5000 psi) and 190 L/min (50 USgpm)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-1


Section Contents
Load Control Valves

Typical Application Rated Flow


Model Pressure bar (psi) l/mim (USgpm) Page
Load Control Valves - Application guidelines, features and benefits .............................................................................. H-3
Functional symbols ......................................................................................................................................................... H-5
Counterbalance valves
CBV1/2-10......................................350 (5000) ..............................................60 (15) ...................................................... H-6
CBV1/2-12 .....................................350 (5000) ..............................................114 (30) .................................................... H-8
Vented counterbalance valves
VCB1-10.........................................350 (5000) ..............................................60 (15) .................................................... H-10
VCB1-12.........................................350 (5000) ..............................................114 (30)................................................... H-12
Motion control valves
MCV1-16........................................210 (3000)...............................................151 (40) .................................................. H-14
MCV1-20 .......................................210 (3000)...............................................190 (50) .................................................. H-16
Dual motion control valve
MCV2-20 .......................................210 (3000)...............................................190 (50) .................................................. H-18
Dual motion control valve with load lock
MCV4-16 .......................................210 (3000)...............................................151 (40) .................................................. H-20

Note
Pilot operated check valves
are covered in Section G.

H-2 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Section Overview
Load Control Valves

Load control valves Pilot operated check valves The 3-ported counterbal- 4-ported counterbalance
Eaton offers a broad range These valves are used: ance valves are offered valve is offered with a wide
of Vickers load control with a wide variety of variety of standard
For position load locking standard housings with housings with SAE and
valving including counter-
balance, motion control and As an alternative to SAE and BSPP port BSPP port options.
pilot operated check valves. counterbalance valves options. Aluminum and NOTE: For applications
The prime function of load where neither the over- steel housings are available where the flow rate will not
controls is to prevent loads running loads or release in the following styles: exceed 37,8 L/min (10
from running ahead of speed are factors in the Inline single USgpm) for VCB110 and
pump supply and/or to pro- application. 95 L/min (25 Usgpm) for
Inline dual
vide positive load holding. Pilot operated check VCB1-12, the standard C-
These valves provide pre- valves are covered in Inline dual, with integral **-4 housing can be used.
cise and stable motion con- section G shuttle For applications over those
trol. Load control valves are SAE 4-bolt, Code 61 flows or those that require
ideally suited for moving Counterbalance a reduced pressure drop,
Close coupled, nipple
and positioning systems. cartridges, 3-ported housings with the slot
mounted
These products include feature or a C-**-4U cavity
The CBV are single car- Gasket mounted single are required.
both screw-in cartridge and tridge type counterbalance
inline housing valves to valves that have: Gasket mounted dual Aluminum and steel
meet the majority of load Various bolt on manifolds housings are available in
control requirements. A check feature allowing the following styles:
free flow in one direction for Eaton hydraulic
motors Inline single
Load control A relief feature
application tips controlling flow in the Inline dual
other direction
Vented counterbalance H
cartridges, 4-ported Gasket mounted single
3-ported counterbalance A pilot signal that over-
valves The VCB1-10 and VCB1-12
rides the relief setting Motion control valves
are single cartridge type
These valves are used with providing the counterbal- counterbalance valves that These are inline housing
an open center on/off direc- ance function. have: type motion control or
tional valve for: The CBV*10 series prod- counterbalance valves that
A check feature that
Precise control of over- ucts are capable of handling utilize separate cartridges
allows free flow in one
running loads flows to up 60 L/min (15 to perform the counterbal-
direction
USgpm) and pressures up ance function as described
Protection from pump A relief feature that con-
to 350 bar (5000 psi). in the 3-ported version. The
cavitation trols flow in the other 16 and 20 series valves are
Preventing actuator from The CBV*12 series prod- direction and available in both single and
running ahead of the ucts are capable of handling
A pilot signal that over- dual functions. The 16
pump supply and flows up to 114 L/min (30
rides the relief setting, series is capable of
USgpm) and pressures up
Providing load holding providing the counterbal- handling flows up to 151
to 350 bar (5000 psi).
and hose failure safety ance function L/min (40 USgpm) and
These valves are available pressures up to 210 bar
Vented (4-ported) with 4:1 and 10:1 pilot The additional 4th port on (3000 psi). The 20 series
counterbalance valves ratios. As a general rule, a this valve provides an exter- valves are capable of han-
These valves are used for: low pilot ratio will provide nal drain that makes the dling 190 L/min (50 USgpm)
better motion control and valve insensitive to back and pressures up to 210 bar
Precise control of pressure at port 2, when
stability in systems with (3000 psi). Both series offer
overrunning loads the valve is piloted open.
higher capacitance (spongy) a 10:1 pilot ratio.
Regenerative cylinder and inductance (high inertial This is particularly useful in
circuits loads). A high pilot ratio regenerative circuits, meter-
improves the efficiency of a out circuits, servo valves
Meter-out control and
hydraulic system, but and proportional valves cir-
providing load holding
motion control stability may cuits. This valve is available
and hose failure safety
suffer. with a 4:1 pilot ratio. The
with proportional control
valves

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-3


Features and benefits Do not remove the spring The pilot-to-open valves housings with SAE and
of counterbalance & wire from the adjusting positively lock a load from BSPP port options in the
motion controls: screw. port 1 to port 2 until pilot following configurations:
Positive load holding in 3. Tighten the jam nut to pressure applied to port 3 Inline single
any position. secure the desired pres- is sufficient to unseat the Inline dual
sure setting. valve. This then permits SAE, 4-bolt
Thermal expansion relief flow from port 1 to port 2. Close coupled, nipple
protection. NOTE CBV*10 spring wire The load can also be mounted
Cartridge valves may be must not be removed. released through means of Gasket mounted single
installed directly into cavi- Removal will affect the min- an optional screw type Gasket mounted dual
ties machined in the imum adjustment of the override.
valve. These valves fit into
actuator body. This The POC*-10 covers flow C*3S cavities.
reduces the number of up to 60 L/min (15 USgpm).
potential leak points and CAUTION Four standard cracking
The POC*-12 covers flow pressures permit energy
simplifies plumbing. Care should be up to 114 L/min (30
taken to ensure savings, while tailoring
Line mounting of single USgpm). With infinite life the hydraulic system
or dual functions can the load is sup- qualification to a fatigue
ported by mechanical requirements to minimize
simplify installation of pressure rating of 310 bar shock.
load control valves in means when servicing or (4500 psi), these POC
many applications. removing the cartridge valves are suitable for use Unique dual spring
valve. in a broad range of load design provides high
Dual function models operational efficiency and
CAUTION control applications with
that can introduce low- a low pressure spring
typical system operating
pressure makeup flow to Hydraulically option for effective anti-
pressures up to 350 bar
prevent cavitation can be released dead- cavitation protection.
(5000 psi). Tailoring of the
line mounted in hydro- man brakes circuit to gain energy sav- Unique design provides
static transmissions. should be used to lock ings while minimizing shock compact package and
When used with paired static loads due to motor is obtained through the use low pressure drops that
cylinders, counterbalance and cylinder leakage. of several standard cracking match or exceed current
valves will help to bal- pressure ranges from 2,0 market expectations and
ance the load by transfer- CAUTION bar (30 psi) to 7 bar (100 provide for excellent
ring part of the load from Counterbalance psi). When anti-cavitation repeatability and stability.
the heavily loaded cylin- valves can be protection is required, the
der to the less loaded 3:1 pilot ratio satisfies
damaged by 0,30 bar (5 psi) spring
cylinder. simple load holding appli-
severe decompression should be used. For those
cation requirements,
When used with an open shock. To help prevent applications where pilot
while providing smooth
center directional control shock damage, a restriction pressure may not always
operation and longer
valve, deceleration con- may be added between the be available, the valve can
operating life.
trol can be provided. cylinder and the counterbal- be ordered with an optional
ance valve. adjustable override. Optional adjustable over-
Adjusting counter ride releases the load for
CAUTION Pilot-to-open valves are
balance cartridge valve situations where pilot
suitable for a wide range of
Counterbalance pressure is not always
pressure setting: applications including aerial
valves are not available.
Counterbalance valves work platforms, boom
relief valves or
adjust in the opposite direc- truck, machine tool and
energy-saving devices. WARNING
tion of other pressure con- round bailer markets.
Stability problems may be
trol valves. Turning the Pilot operated check Do not use Pilot-
encountered when system
adjuster counterclockwise valves are covered in to-open check
operating pressure goes
increases the valve setting; section G. valves in load
below 50 bar (700 psi).
turning the adjustment holding applications where
Features and benefits either overrunning loads are
clockwise lowers the pres- Pilot operated of pilot operated
sure setting, releasing the possible or load release
check valves check valves: speed is critical. Failure to
load.
The POC*-10 and POC*-12 Simple load holding observe these guidelines
1. Loosen the jam nut. series of pilot-to-open check device. Low cost alterna- may result in bodily injury
2. Turn the adjusting screw valves complement the tive to more complex or damage to equipment.
clockwise to reduce the CBV*-10 and CBV*-12 coun- solutions when overrun-
pressure setting, or coun- terbalance cartridges and ning loads are not pres- WARNING
terclockwise to increase are physically interchange- ent and / or control of For pressure over
the pressure setting. able with them. The POCs load release speed is not 210 bar (3000
provide a low cost alterna- required. psi) use steel
tive to load control when
Provides high operational housings.
the dynamics of neither
overrunning loads nor load efficiency and low spring
release speed are factors to settings.
be considered in the design Valves are offered with a
of the hydraulic circuit for wide variety of standard
the load to be controlled.

H-4 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Functional
Symbols
load Control Valves

CBV cartridges in housings VCB cartridges in housings POC cartridges in housings*


I - Inline Mounted I - Inline Mounted I - Inline Mounted
1 F Type S Type
C1
2 3 2 3
3
3 Pilot
1 1
V2 4 2 B - 4-Bolt Pad (Size 12 only)
B - 4-Bolt Pad (Size 12 only) F Type S Type
G - Gasket Mounted, Single
C1 C1 Pilot C1 Pilot
C1 C2
Pilot Pilot

3 Pilot V1 V1
V2
V2 3 Pilot V1 N - Close Coupled, Nipple Mounted
N - Closed Coupled, F Type S Type
Vent
Nipple Mounted C1 C2 C1 C2
C2 D - Dual Line Mounted
Vent V2 V1
C1
V1 V2 V1 V2
G - Gasket Mounted, Single
V1 V2 F Type S Type
G - Gasket Mounted, Single C2 C1 C1 C2 C1 C2
C2
C1
V1 V2 V1 V2 H
D - Dual Line Mounted
V1 V2 F Type S Type
D - Dual Line Mounted C1 C2 C1 C2
P - Dual Gasket Mounted
V2 V1
V1 V2 V1 V2
P - Dual Gasket Mounted
F Type S Type
C1 C2 C1 C2
C2 C1

H - Dual, bolt on for H or T


motor V1 V2 V1 V2
2K - Dual, bolt on for 2000
series motor * Pilot operated check valve data sheets
M - Dual Counterbalance are included in Section G
Line Mounted
w/Integral Shuttle
V2 S V1

C2 C1

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-5


CBV1/2-10
Counterbalance valve

Description Operation
The CBV*-10 is a 3-ported, The CBV counterbalance Flow from port 1 to port 2 setting has been reached or
externally piloted, screw-in valve allows free flow from is blocked until either the sufficient pilot pressure has
cartridge type counterbal- port 2 (inlet) to port 1 (load). predetermined pressure been applied to port 3
ance valve. (pilot).

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
3 Rated flow 60 L/min (15 USgpm)
Cracking pressure @ 1 L/min (0.25 USgpm) 30 - 62-210 bar (900-3000 psi)
50 - 186-350 bar (2700-5000 psi)
2 Internal leakage 5 drops/min. max. Port 1 to Port 2 @ 77% of crack pressure
Temperature range -40 to 120C (-40 to 248F)
Sectional View Cavity C-10-3S
Pilot ratio 4:1, 10:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,23 kg. (0.50 lbs.)
Seal kit 02-173019 Buna-N
02-173020 Viton
Viton is a registered trademark of E.I. DuPont

CAUTION WARNING
Adjustments For pressure over
exceeding 350 bar 210 bar (3000 psi)
(5000 psi) may use steel housing.
3 damage the body.
Pressure Drop Curves
2 Cartridge only

For 4:1 Ratio


Pilot pressure, =
Cracking pressure + (5 x Port 2 pressure) - Port 1 pressure
4
For 10:1 Ratio
Pilot pressure, =
Cracking pressure + (11 x Port 2 pressure) - Port 1 pressure
10 A - Piloted open port 1 to port 2
B - Free flow port 2 to port 1

H-6 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
CBV1/2-10

CBV* 10 (V) * * *** * **/** 00

1 2 3 4 5 6 7 8 9 10 11

1 Valve function 7 Housing port sizes


CBV - Counterbalance valve PORT SIZE VALVE BODY CODES
I N/G/P D/M H/2K
2 Pilot ratio Aluminum Steel Aluminum Steel Aluminum Steel Aluminum
1- 4:1 SAE 6 A6H* S6T A6H A6T A6H S6T -
2 - 10:1 SAE 8 A8H S8T - - A8H S8T -
3 Valve size SAE 10 - S10T - - A10H S10T A10H
10 - Size 10 1/4" BSPP A2G - - - A2G S2G -
3/8" BSPP A3G* S3G A3G A3G A3G S3G -
4 Seals
1/2" BSPP - S4G - - A4G S4G -
Blank - Buna-N * Light Duty Housing is available, to specify, substitute H or G with T or B respectively.
V - Viton For housing part numbers and dimensions see section J.
Note -P,H, 2K, D and M bodies contain two CBV valves.
5 Adjustment options
S - Screw with locknut
8 Free flow crack pressure 9 Pressure range 11 Special features
C - Cap over screw
K - Hand knob A - 1,4 bar (20 psi) (standard) 30 - 62-210 bar (900-3000 psi) 00 - None
B - 0,28 bar (4 psi) (anti 50 - 186-350 bar (2700- (Only required if valve has
6 Valve Body cavitation) 5000 psi) special features, omit if 00)
O - Cartridge only C - 1.4 bar (20 psi) with low
leak poppet * 10 Pressure setting
I - Inline body
N - Close coupled, nipple D - 0.28 bar (4 psi) with low (optional)
mounting leak poppet * (Specified by customer in 100
G - Gasket mounted, single * Low leak poppet is only available on
CBV2-**. psi increments) for example:
D - Dual counterbalance, 20 - 140 bar (2000 psi) H
Only apply B and D options if required in
line mounted your application, these are not preferred 35 - 240 bar (3500 psi)
M - Dual counterbalance, options.
line mounted with CBV Valves should not be applied with
integral shuttle valve closed center directional valves.
P - Dual counterbalance,
gasket mounted
H - Dual counter balance, Dimensions
bolt on manifold for mm (inch)
H, S or T series motor
C Adjustment (Cap over screw) K Adjustment (Hand knob) S Adjustment (Screw w/locknut)
2K -Dual counter balance,
bolt on manifold for 31,75
2000 series motor
(1.25) Nom.

Torque cartridge 12,7


in housing: (0.50) hex
65,6 (2.58) 61,0 (2.40)
A - 47-54 Nm (35-40 ft.lbs) 55,4 (2.18 )
61,7 (Nominal (Nominal 25,4
S - 68-75 Nm (50-55 ft.lbs) (2.43) full in) Nominal
full out) (1.0) h ex
Nominal full out

3(P) 0.875-14 Thd. 48,0


(1.89)
2(V)
Note 17,4
Turn screw or knob clock- 1(C) (0.68 6)
wise to reduce pressure
19,0
setting and release load.
(0.748)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-7


CBV1/2-12
Counterbalance valve

Description Operation
The CBV*-12 is a 3-ported, The counterbalance valve to port 2 is blocked until reached or sufficient pilot
externally piloted, screw-in allows free flow from port 2 either the predetermined pressure has been applied
cartridge type counterbal- to port 1. Flow from port 1 pressure setting has been to port 3 (pilot).
ance valve.

Functional Symbol RATINGS AND SPECIFICATIONS


Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
1
Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
3
Cracking pressure @ 1 L/min (0.25 USgpm) 30 - 62-210 bar (900-3000 psi)
50 - 186-350 bar (2700-5000 psi)
2 Internal leakage 5 drops/min. max. Port 1 to Port 2 @ 77% of crack pressure
Temperature range -40 to 120C (-40 to 248F)
Sectional View Cavity C-12-3S
Pilot ratio 4:1, 10:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,36 kg. (0.79 lbs.)
Seal kit 02-180095 Buna-N
02-165887 Viton
Viton is a registered trademark of E.I. Dupont
Pressure Drop Curves
Cartridge only
Flow L/min (21,8 cSt oil @ 49C)
0 20 40 60 80 100
WARNING
3 300 20
For pressure over

Pressure Drop bar


Pressure Drop psi

210 bar (3000 psi)


2 use steel housing. 15
200
CAUTION
10
Adjustments A
1 exceeding 350 bar 100
(5000 psi) may B 5
damage the body.
0
For 4:1 Ratio 0 5 10 15 20 25 30
Pilot pressure, = Flow USgpm (105 SUS oil @120F)
Cracking pressure + (5 x Port 2 pressure) - Port 1 pressure
4
A - Piloted open port 1 to port 2
For 10:1 Ratio B - Free flow port 2 to port 1
Pilot pressure, =
Cracking pressure + (11 x Port 2 pressure) - Port 1 pressure
10

H-8 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
CBV1/2-12

CBV* 12 (V) * * * *** * **/** 00

1 2 3 4 5 6 7 8 9 10 11 12

1 Valve function 8 Housing port sizes 10 Pressure range


CBV - Counterbalance valve PORT SIZE VALVE BODY CODES 30 - 62-210 bar
I B N/G/P D/M (900-3000 psi)
2 Pilot ratio 50 - 186-350 bar
SAE 8 - - 8T -
1 - 4:1 (2700-5000 psi)
2 - 10:1 SAE 10 10T - - 10T
SAE 12 12T - - 12T 11 Pressure setting
3 Valve size 1/2" BSPP 4G - 4G 4G (optional)
12 - Size 12 3/4" BSPP 6G - - - (Specified by customer in 100
psi increments) for example:
4 SAE-Code 61 6T 20 - 140 bar (2000 psi)
Seals
For housing part numbers and dimensions see section J. 35 - 240 bar (3500 psi)
Blank - Buna-N
V - Viton
9 Free flow crack pressure 12 Special features
5 Adjustment
A - 2,0 bar (25 psi) (standard) D - 0.28 bar (4 psi) with low 00 - None
S - Screw with locknut B - 0,30 bar (4 psi) leak poppet * (Only required if valve has
C - Cap over screw (anti-cavitation) * Low leak poppet is only available on special features, omit if 00)
K - Hand knob CBV2-**.
C - 1.4 bar (20 psi) with low
Only apply B and D options if required in
leak poppet * your application, these are not preferred
6 Valve body options.
O - Cartridge only CBV Valves should not be applied with
I - Inline body closed center directional valves.
B - SAE 4 - Bolt pad
N - Close coupled, nipple H
mounting Dimensions
G - Gasket mounted, single mm (inch)
D - Dual counterbalance,
line mounted Torque cartridge in housing:
M - Dual counterbalance, A - 81-95 Nm (60-70 ft.lbs)
line mounted with S - 102-115 Nm (75-85 ft.lbs)
integral shuttle valve C Adjustment K Adjustment S Adjustment
P - Dual counterbalance,
gasket mounted
31,75 (1.25)
7 Valve housing material 4,0 (0.16) hex
nom. 13,0 (0.50) hex
A - Aluminum
S - Steel

66,8 (2.63)
70,4 75,4 (2.97) 70,0 (2.75) Nom. full out
(2.77) (Nom. (Nom.
Nom. full out) full in) 53,8 (2.12)
31,75 (1.25)
Nom. full in
hex

1.063-12 Thd.

3 57,7
(2.27)
Note 2
Turn screw or knob clock-
wise to reduce pressure 1 22,17 (0.873)
setting and release load. 23,75 (0.935)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-9


VCB1-10
Vented counterbalance
valve

Description Operation
The VCB1-10 is a 4-ported, The VCB1-10 counterbal- from port 1 to port 2 is sufficient pilot pressure has
externally piloted, screw-in ance valve will allow free blocked until either a prede- been sensed on
cartridge type counter- flow from port 2 to port 1 termined pressure setting port 3 (pilot). Port 4 is
balance valve with the through a built in check has been reached or vented to tank.
separate vent. This separate valve. Flow
vent makes the valve
insensitive to back pressure
at port 2. RATINGS AND SPECIFICATIONS
Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
Typical application pressure (all ports) 350 bar (5000 psi)
Functional Symbol Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
1 Rated flow 60 L/min (15 USgpm)
Cracking pressure @ 1 L/min (0.25 USgpm) 30 - 62-210 bar (900-3000 psi)
50 - 186-350 bar (2700-5000 psi)
3 Internal leakage 5 drops/min. max. Port 1 to Port 2 @ 77% of crack pressure
Temperature range -40 to 120C (-40 to 248F)
4 Cavity C-10-4 or C-10-4U
2
Pilot ratio 4:1
Sectional View Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing materials Aluminum or steel
Weight cartridge only 0,36 kg. (0.79 lbs.)
Seal kit 889625 Buna-N
566080 Viton
Viton is a registered trademark of E.I. Dupont

Pressure Drop Curves


Cartridge only

Flow L/min (21,8 cSt oil @ 49C)


WARNING
10 20 30 40 50
For pressure over 400 30
210 bar (3000 psi) Pressure Drop bar
Pressure Drop psi

4 use steel housing.


300
CAUTION 20
Adjustments 200
3 exceeding 350 bar
(5000 psi) may 10
100 B
damage the body.
2 A
Note
0 0
Valve should be set 1.3 0 3 6 9 12 15
1 times load induced pres-
sure. Flow USgpm (105 SUS oil @120F)
For 4:1 Ratio
Crack pressure Load pressure
Pilot pressure = A - Piloted open port 1 to port 2
Pilot ratio
B - Free flow port 2 to port 1

H-10 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
VCB1-10

VCB1 10 (V) * * **** * **/** 00

1 2 3 4 5 6 7 8 9 10 11

1 Valve function 7 Housing port sizes


VCB - Vented counterbalance PORT SIZE VALVE BODY CODES
valve I D G
Alum. Steel Alum. Steel Alum. Steel
2 Pilot ratio SAE 6 A6H* S6T A6H S6T A6H S6T
1 - 4:1
SAE 8 A8H** S8T** A8H** S8T** A8H** S8T**
3 Valve size SAE 10 A10H** - - S10T - -
10 - Size 10 1/4" BSPP A2G - - - - -
3/8" BSPP A3G** S3G** A3G** S3G** A3G S3G**
4 Seals
* Light Duty Housing is available, to specify, substitute H with T respectively. 10 Pressure setting
Blank - Buna-N **
Housings with slot.
V - Viton (optional)
Note - for housing part numbers and dimensions see section J.
(Specified by customer in 100
5 Adjustment psi increments) for example:
8 Free flow crack pressure 9 Pressure range 20 - 140 bar (2000 psi)
S - Screw with locknut
C - Cap over screw A - 1,4 bar (20 psi) (standard) 30 - 62-210 bar (900-3000 psi) 35 - 240 bar (3500 psi)
K - Hand knob B - 0,28 bar (4 psi) (anti- 50 - 186-350 bar (2700-
cavitation) 5000 psi) 11 Special features
6 Valve body 00 - None H
O - Cartridge only (Only required if valve has
I - Inline body special features, omit if 00)
G - Gasket mounted, single
D - Dual counterbalance,
line mounted
K Adjustment S Adjustment
31,75 (1.25) nom. 4,0 (0.16) hex
Dimensions C Adjustment
mm (inch)

Torque cartridge in housing: 12,7 (0.50) hex


A - 47-54 Nm (35-40 ft.lbs)
S - 68-75 Nm (50-75 ft.lbs) 53,8 45,0
(2.12) (1.77)
25,4 (1.00) hex 31,8 54,4
(1.25) (2.14)

0.875-14 Thd.
Note
Turn screw or knob clock-
wise to reduce pressure 4
setting and release load. 63,8
(2.51)
3

1
15,80 (0.622)
17,40 (0.686)
19,00 (0.748)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-11


VCB1-12
Vented counterbalance
valve

Description Operation
The VCB1-12 is a 4-ported, The VCB1-12 counterbalance Flow from port 1 to port 2 is or sufficient pilot pressure
externally piloted, screw-in valve will allow free flow blocked until either a prede- has been sensed on
cartridge type counter- from port 2 to port 1 through termined pressure setting port 3 (pilot). Port 4 is
balance valve with the a built in check valve. has been reached vented to tank.
separate vent. This separate
vent makes the valve insen- RATINGS AND SPECIFICATIONS
sitive to back pressure at Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
port 2. Typical application pressure (all ports) 350 bar (5000 psi)
Cartridge fatigue pressure (infinite life) 350 bar (5000 psi)
Rated flow 114 L/min (30 USgpm)
Functional Symbol Cracking pressure @ 1 L/min (0.25 USgpm) 30 - 35-210 bar (500-3000 psi)
1 50 - 175-350 bar (2500-5000 psi)
Internal leakage 5 drops/min. max. Port 1 to Port 2 @ 77% of crack pressure
Temperature range -40 to 120C (-40 to 248F)
3 Cavity C-12-4 or C-12-4U
Pilot ratio 4:1
4 Fluids All general purpose hydraulic fluids such as:
2 MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Sectional View Standard housing materials Aluminum or steel
Weight cartridge only 0,37 kg. (0.81 lbs.)
Seal kit 02-160979 Buna-N
02-160980 Viton
Viton is a registered trademark of E.I. Dupont

Pressure Drop Curves


Cartridge only

WARNING
For pressure over
210 bar (3000 psi) Flow L/min (21,8 cSt oil @ 49C)
use steel housing.
20 40 60 80 100
CAUTION 300 21
4
Pressure Drop bar
Pressure Drop psi

Adjustments
exceeding 350 bar
(5000 psi) may 200 14
3 damage the body.

B 7
2 100
Note
Valve should be set 1.3
A
times load induced 0 0
1 pressure. 0 6 12 18 24 30
Flow USgpm (105 SUS oil @120F)
For 4:1 Ratio
Relief setting Load pressure
Pilot pressure = A - Piloted open port 1 to port 2
Pilot ratio
B - Free flow port 2 to port 1

H-12 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
VCB1-12

VCB1 12 (V) * * **** * **/** 00

1 2 3 4 5 6 7 8 9 10 11

1 Valve function 6 Valve Body 8 Free flow crack pressure 10 Pressure setting

VCB - Vented counterbalance O- Cartridge only A - 1,7 bar (25 psi) (standard) (optional)
valve I - Inline body B - 0,28 bar (4 psi) (anti- (Specified by customer in 100
G- Gasket mounted, single cavitation) psi increments) for example:
2 Pilot ratio D- Dual counterbalance, 20 - 140 bar (2000 psi)
line mounted 9 Pressure range 35 - 240 bar (3500 psi)
1 - 4:1
30 - 25-210 bar (500-3000 psi)
3 Valve size 50 - 175-350 bar (2700- 11
7 Special features
12 - Size 12 Housing port sizes 5000 psi)
00 - None
PORT SIZE VALVE BODY CODES (Only required if valve has
4 Seals I/D G special features, omit if 00)
Blank - Buna-N Alum. Steel Alum. Steel
V - Viton SAE 8 - - A8T** S8T**
5 Adjustment
SAE 10 A10T S10T - -
SAE 12 A12T** S12T** - -
S - Screw with locknut
C - Cap over screw 3/8" BSPP - - A4G** S4G**
K - Hand knob 1/2" BSPP A4G S4G** - -
**Housing with slot
H
Note - for housing part numbers and dimensions see section J*.

Dimensions 4,0 (0.16) hex


mm (inch) S Adjustment
Torque cartridge in housing: C Adjustment
K Adjustment
A - 81-95 Nm (60-70 ft.lbs) 50,4
31,75 12,7 (0.50) hex
S - 102-115 Nm (75-85 ft.lbs) (1.98)
41,0
(1.61)
31,7 (1.25) hex
49,5
(1.95)
1.062-12 Thd.

4
91,6
(3.60)
3

Note
Turn screw or knob clock- 2
wise to reduce pressure set-
ting and release load.
1
20,57 (0.810)
22,17 (0.873)
23,75 (0.935)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-13


MCV1-16
Motion control valve

Description Operation
The MCV1-16 is an inline The MCV1-16 is an inline valve controls a moving load will also lock or hold a load in
housing type motion control housing type motion control and prevents loads from any position and provides for
or load holding valve. This or load holding valve. This running ahead of a pump. It thermal expansion relief.
valve controls a moving load
and prevents loads from
RATINGS AND SPECIFICATIONS
running ahead of a pump. It
will also lock or hold a load in Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
any position and provides for Typical application pressure (all ports) 210 bar (3000 psi)
thermal expansion relief. Rated flow 151 L/min (40 USgpm)
Free flow cracking pressure @ 1 L/min (0.25 USgpm) 13 - 3,4-8,4 bar (50-1300 psi)
35 - 13,6-240 bar (200-3500 psi)
Internal leakage Port C to V less than 5 drops/min. max. @ 210 bar (3000 psi)
Functional Symbol Temperature range -40 to 120C (-40 to 248F)
C Pilot ratio 11:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing material Aluminum
Pilot
Weight 4,50 kg. (10.00 lbs.)
Seal kits (Check valve) 565810 Buna-N
889609 Viton
V Seal kits (Relief valve) 565810 Buna-N
889609 Viton
Sectional View Viton is a registered trademark of E.I. Dupont

Pilot pressure calculation for 11:1 Ratio


Nominal pressure to open valve by remote control
Pilot pressure =
Cracking pressure + (12 x Port V pressure) - Port C pressure
11
C
V Pressure Drop Curves

Free Flow (V to C) Piloted Open (C to V)


Pilot
Flow L/min (21,8 cSt oil @ 49C) Flow L/min (21,8 cSt oil @ 49C)
0 50 100 150 0 50 100 150
250 300 20
15
Pressure Drop bar
Pressure Drop psi

Pressure Drop (bar)

250
Pressure Drop (psi)

200
15
200
150
10
150
10
100
100
5 5
50 50

0 0 0 0
0 10 20 30 40 0 10 20 30 40
Flow USgpm (105 SUS oil @120F) Flow USgpm (105 SUS oil @120F)

H-14 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
MCV1-16

MCV1 16 (V) * *** **/** 00

1 2 3 4 5 6 7 8

1Valve Function 3 Seals 5


Port size 7 Pressure setting
MCV1 - Motion control valve Blank - Buna-N 12T - SAE 12 (light duty) Optional - specify in 100 psi
V - Viton 6B - 3/4 BSPP (light duty) ranges. If not specified, set at:
2 Size 20 - 140 bar (2000 psi)
6 Cracking pressure range 35 - 240 bar (3500 psi)
16 - 16 Size 4 Adjustment
K - Hand knob 13 - 3,4-8,4 bar (50-1300 psi)
S - Screw with locknut 35 - 13,6-240 bar 8 Special features
(200-3500 psi)
00 - None
(Only required if valve has
special features, omit if 00)

Installation
Dimensions
mm (inch) 31,8
63,5 (1.25) H
Torque cartridge in housing (2.50)
108-122 Nm (80-90 ft.lbs)
63,5 47,6 (1.88)
(2.50)

RV316S

CV116P05
100,0
63,5 9,5 (0.38) (3.94)
(2.50)

28,6
(1.13) 60,4 V
76,3 (2.38)
(3.00)
C 85,7 133,4
(3.38) (5.25)
38,1 1,1 (0.44)
(1.50) 2 places

Pilot SAE 6 139,7 (5.50) 31,8


165,1 (6.50) 63,5 (1.25)
(2.50)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-15


MCV1-20
Motion control valve

Description Operation
The MCV1-20 is an inline This valve allows free flow the opposite direction until pilot pressure has been
housing type motion control from the V port to the C either the relief setting is applied to the Pilot port.
or load holding valve. This port and blocks flow in reached or until sufficient
valve controls a moving load
and prevents loads from run- RATINGS AND SPECIFICATIONS
ning ahead of a pump. It will Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
also lock or hold a load in any Typical application pressure (all ports) 210 bar (3000 psi)
position and provides for
Rated flow 190 L/min (50 USgpm)
thermal expansion relief.
Free flow cracking pressure @ 1 L/min (0.25 USgpm) 13 - 3,4-8,4 bar (50-1300 psi)
35 - 13,6-240 bar (200-3500 psi)
Internal leakage Port C to V less than 5 drops/min. max. @ 210 bar (3000 psi)
Temperature range -40 to 120C (-40 to 248F)
Functional Symbol
Pilot ratio 10:1
C Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing material Aluminum
Pilot Weight 5,40 kg. (12.00 lbs.)
Seal kits (Check valve) 889615 Buna-N
889619 Viton
V Seal kits (Relief valve) 565810 Buna-N
889609 Viton
Sectional View Viton is a registered trademark of E.I. Dupont

Pilot pressure calculation for 10:1 Ratio


Nominal pressure to open valve by remote control
Pilot pressure =
Cracking pressure + (11 x Port V pressure) - Port C pressure
10

V
Pressure Drop Curves
C

Pilot
Free Flow (V to C) Piloted Open (C to V)
Flow L/min (21,8 cSt oil @ 49C) Flow L/min (21,8 cSt oil @ 49C)
40 80 120 160 200 40 80 120 160 200
100 7 600 40
6
Pressure Drop bar

Pressure Drop bar


Pressure Drop psi

Pressure Drop psi

500
80
5 30
400
60 4
300
3 20
40
200
2
10
20 100
1
0 0
0 10 20 30 40 50 0 10 20 30 40 50
Flow USgpm (105 SUS oil @120F) Flow USgpm (105 SUS oil @120F)

H-16 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
MCV1-20

MCV1 20 (V) * *** **/** 00

1 2 3 4 5 6 7 8

1 Valve Function 4 Adjustment 6 Cracking pressure range 8 Special features

MCV1 - Motion control valve K - Hand knob 13 - 3,4-8,4 bar (50-1300 psi) 00 - None
S - Screw with locknut 35 - 13,6-240 bar (Only required if valve has
2 Size (200-3500 psi) special features, omit if 00)
5 Port size
20 - 20 Size
7 Pressure setting
16T - SAE 16 (light duty)
3 Seals 8B - 1 BSPP (light duty) Optional - specify in 100 psi
Blank - Buna-N ranges. If not specified, set at:
V - Viton 20 - 140 bar (2000 psi)
35 - 240 bar (3500 psi)

Installation
Dimensions
mm (inch)
63,5
Torque CV2-20 cartridge (2.50)
in housing 128-155 H
Nm (95-115 ft.lbs)
44,4 (1.75)
Torque RV3-16 cartridge
in housing 108-122 109,5 (4.31)
Nm (80-90 ft.lbs)

RV316S
84,1
(3.31)

CV220P05

44,4
(1.75)
82,5
(3.25) 85,7
133,3 (3.37) V
C (5.25) 10,3(0.406) 152,4
through, (6.00)
2 places
44,4
(1.75)

SAE 6

31,7 119,7 (5.50) 31,7


Pilot (1.25) 165,1 (6.50) (1.25)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-17


MCV2-20
Dual-motion control valve

Description Operation
The MCV2-20 is a dual This valve allows free flow in the opposite direction pilot pressure has been
inline housing type motion from the V port to the until either the relief setting applied from the opposite
control or load holding C ports and blocks flow is reached or until sufficient V port.
valve. This valve controls a
RATINGS AND SPECIFICATIONS
moving load and prevents
loads from running ahead Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
of a pump. It will also lock Typical application pressure (all ports) 210 bar (3000 psi)
or hold a load in any posi- Rated flow 190 L/min (50 USgpm)
tion and provides for ther- Free flow cracking pressure @ 1 L/min (0.25 USgpm) 13 - 3,4-8,4 bar (50-1300 psi)
mal expansion relief. 35 - 13,6-240 bar (200-3500 psi)
Functional Symbol Internal leakage, Port C to V less than 5 drops/min. max. @ 210 bar (3000 psi)
Temperature range -40 to 120C (-40 to 248F)
C1 C2 Pilot ratio 10:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing material Aluminum
Weight 10,0 kg. (21.50 lbs.)
Seal kits (Check valve) 889615 Buna-N
V1 V2 889619 Viton
Seal kits (Relief valve) 565810 Buna-N
Sectional View 889609 Viton
Viton is a registered trademark of E.I. Dupont

Pilot pressure calculation for 10:1 Ratio


Pilot pressure, nominal at port 3 =
Cracking pressure + (11 x Port 2 pressure) - Port 1 pressure
10

Pressure Drop Curves

Free Flow Piloted Open


(V1 to C1 or V2 to C2) (C1 to V1 or C2 to V2)
Flow L/min (21,8 cSt oil @ 49C) Flow L/min (21,8 cSt oil @ 49C)
40 80 120 160 200 40 80 120 160 200
100 7 600 40
6
Pressure Drop bar
Pressure Drop psi

Pressure Drop bar


Pressure Drop psi

80 500
5 30
400
60 4
300 20
40 3
200
2
20 10
1 100

0 0
0 10 20 30 40 50 0 10 20 30 40 50
Flow USgpm (105 SUS oil @120F) Flow USgpm (105 SUS oil @120F)

H-18 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code
MCV2-20

MCV2 20 (V) * *** **/** 00

1 2 3 4 5 6 7 8

1Valve Function 3 Seals 6 Cracking pressure range 8 Special features


MCV2 - Dual-motion Blank - Buna-N 13 - 3,4-8,4 bar (50-1300 psi) 00 - None
control valve V - Viton 35 - 13,6-240 bar (Only required if valve has
(200-3500 psi) special features, omit if 00)
2 Size 4 Adjustment
20 - 20 Size K - Hand knob 7 Pressure setting
S - Screw with locknut Optional - specify in 100 psi
5 Port size ranges. If not specified, set at:
20T - SAE 12 (light duty) 20 - 140 bar (2000 psi)
8B - 1 BSPP (light duty) 35 - 240 bar (3500 psi)

Installation
Dimensions
mm (inch)

Torque CV2-20 cartridge


in housing 128-155 127,0 H
Nm (95-115 ft.lbs) (5.00)
Torque RV3-16 cartridge 0.375-16 x 50
in housing 108-122 deep
Nm (80-90 ft.lbs) 4 places
55,6 (2.19)
120,6 (4.75)

RV316S
(2 reqd) 84,1
(3.31)
CV220P
(2 reqd)

44,4
(1.75) 85,7
(3.37)
V2 V1

C2 C1
152,4
(6.00)

31,7
165,1 (6.50) (1.25)
95,3 (3.75)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-19


MCV4-16
Dual-motion control valve

Description Operation
The MCV4-16 is a dual inline This valve allows free flow in the opposite direction until pilot pressure has been
housing type motion control from the V ports to the either the relief setting is applied from the opposite
or load holding valve. This C ports and blocks flow reached or until sufficient V port.
valve controls a moving load
and prevents loads from run- RATINGS AND SPECIFICATIONS
ning ahead of a pump. It will Performance data is typical with fluid at 21,8 cSt (105 SUS) and 49C (120F)
also lock or hold a load in any Typical application pressure (all ports) 210 bar (3000 psi)
position and provides for Rated flow 151 L/min (40 USgpm)
thermal expansion relief and
Free flow cracking pressure @ 1 L/min (0.25 USgpm) 13 - 3,4-8,4 bar (50-1300 psi)
make-up oil. 35 - 13,6-240 bar (200-3500 psi)
Internal leakage Port C to V less than 5 drops/min. max. @ 210 bar (3000 psi)
Functional Symbol Temperature range -40 to 120C (-40 to 248F)
C1 C2 Pilot ratio 11:1
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration Cleanliness code 18/16/13
Standard housing material Aluminum
Weight 8,0 kg. (18 lbs.)
Seal kits (Check valve) 565810 Buna-N
V1 Tank V2 889609 Viton
Seal kits (Relief valve) 565810 Buna-N
Sectional View 889609 Viton
Viton is a registered trademark of E.I. Dupont

Pilot pressure calculation for 11:1 Ratio


Nominal pressure to open valve by remote control
Pilot pressure =
Cracking pressure + (12 x Port V pressure) - Port C pressure
11

Pressure Drop Curves

Free Flow Piloted Open


(V1 to C1 or V2 to C2) (C1 to V1 or C2 to V2)
Flow L/min (21,8 cSt oil @ 49C) Flow L/min (21,8 cSt oil @ 49C)
0 50 100 150 0 50 100 150
250 600 40
15
Pressure Drop bar
Pressure Drop bar

Pressure Drop psi


Pressure Drop psi

500
200
30
400
150 10
300
20
100
200
5 10
50 100

0 0 0
0 10 20 30 40 0 10 20 30 40
Flow USgpm (105 SUS oil @120F) Flow USgpm (105 SUS oil @120F)

H-20 EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003


Model Code

MCV4 16 (V) * *** **/** 00

1 2 3 4 5 6 7 8

1Valve Function 3 Seals 5 Port size 7 Pressure setting


MCV4 - Dual-motion Blank - Buna-N 12T - SAE 12 (light duty) Optional - specify in 100 psi
control valve V - Viton 6B - 3/4 BSPP (light duty) ranges. If not specified, set at:
20 - 140 bar (2000 psi)
2 Size 4 Adjustment 6 Cracking pressure range 35 - 240 bar (3500 psi)
16 - 16 Size K - Hand knob 13 - 3,4-8,4 bar (50-1300 psi)
S - Screw with locknut 35 - 13,6-240 bar 8 Special features
(200-3500 psi)
00 - None
(Only required if valve has
special features, omit if 00)

Installation Torque cartridge in housing


Dimensions 108-122 Nm (80-90 ft.lbs)
mm (inch)

RV316S H
(2 reqd)
103,9
(4.09)
CV116VP050
(2 reqd)

13,5 (0.531)
mtg. holes
2 plcs.

127,0 C1 C2
44,5 101,6
Tank (5.00)
69,9 (1.75) (4.00)
(2.75)

50,8
12,7 (0.50) 12,7 (0.50) (2.00)
50,8 (2.00)
101,6 (4.00)
127,0 (5.00)

101,6
127,0 (4.00)
(5.00) V1 V2

12,7 (.50)

EATON Vickers Screw-in Cartridge Valves V-VLOV-MC001-E1 June 2003 H-21

You might also like