Professional Documents
Culture Documents
Price Computing
Scale
Service Manual
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used except as
authorized by contract or other written permission. The copyright and the foregoing restriction
on reproduction and use extend to all media in which the information may be embodied.
EXCELL PRECISION CO., LTD.
TABLE OF CONTENTS
1
EXCELL PRECISION CO., LTD.
APPENDIX 1 SPECIFICATION SETTING TABLE ...........................................................................................................26
2
EXCELL PRECISION CO., LTD.
onto the scale or near the exhaust port of ventilating system.
3. Scale must be used under individual socket to avoid the interference of other electric
appliances.
4. Remove any weight that might be on the platter before the scale is switched on.
5. Please note that when or symbol appears on the screen, the scale needs to
be recharged.
T . . . . . . . . . . . . . . . . .
Display Column
1. Weight
Total 6 digits. To display the weight on platter. The left digit is able to display the negative
symbol.
2. Unit Price
Total 5 digits. To display unit price of objects on the platter. The demical point floats two
digits.
3. Total Price
Total 6 digits. To display total price of the objects on platter or the accumulation.
Symbol Display
1. Z : Zero indication.
2. T : Tare indication.
3. M+ : Accumulation indication.
4. : Low battery.
3
EXCELL PRECISION CO., LTD.
Remark:
The keypad,which is for 6preset, has two kinds of shape.One is square (above left), the other
oblong (above right).
0 ~ 9 : Number key. Press the keys to input the numbers (0 ~ 9) and to set unit price.
CE : Press the key to clear the old unit price and then input the new one if you would like to
change the unit price (If the unit price has been input for 3 seconds, you can input the
new one immediately.).
Recall function:
When Unit Price shows 0, press CE to recall the accumulation total times and total
amounts.
P1 ~ P5 : Five groups memory function descriptions
P6 : memory function descriptions (corresponding to 00-79 totally memory 80groups)
T : Press the key to deduct the containers weight and the symbol in Weight will appear.
Z : Zero function.
Press Zero key, the display will show ,then press 4 key right
away. It means auto backlight mode. It is auto backlight mode.
4
EXCELL PRECISION CO., LTD.
Press Zero key, the display will show , then press 5 key right
away. It means without backlight mode.
It is backlight off mode.
<Method 2>
Press 0 key for 2 seconds, the beeper will have beep three times.
The scale will change to backlight mode auto backlight mode or backlight off mode.
Auto backlight mode
When there is a weight on the pan which weight is over 10d or pressing any keys, the
backlight will be on. After back to zero for 10 desonds (the weight is under 10d,),
backlight will be off
The scale will be memorized power off backlight mode.
n Press 00 key two times, the display will show the current priceing unit.
z3 kg kg 3
.
o Using digit key 1 ~ 4 key to select pricing units. The scale will be back to weighing &
price mode. The display will show the symbol indication for the request priceing unit.
1 kg 2 100g 3 twg 4 tl.T
Press 1 ~ 6 to select pricing units of Hongkong.
1 kg 2 100g 3 twg
4 tl.T 5 lb 6 oz
When select the price unit lb, the displaying will show three symbols 3.
When select the price unit oz, the displaying will not show any symbol 3 .
After cancel the power on pricing unit, the scale memorizes the last power off unit.
The last pricing unit shows on the display
Press Zero key, the display will show , then press 8 key, the
5
EXCELL PRECISION CO., LTD.
scale will fix as the request power on pricing unit.
According to the above operation procedure to fix the power on pricing unit, no matter what
pricing unit is used at the operation procedure or power off pricing unit. The power on unit is
fixed as the setting.
If youd like to change power on pricing unit, please follow the working procedures as
follows:
1. Enter to the power on pricing unit working procedure.
2. Cancel the power on pricing unit.
3. Enter the power on pricing unit working procedure.
4. Reset to fix another power on pricing unit.
Operation mode 1. Make sure the scale backs to zero and keeps in kg mode.
2. Press MC key and do not release, the then press . key to show
, the weight display . kg .
3. Release two keys.
4. Key-in pre-calibration weight, the display will show pre-calibration of
weight value in flash. Place full weight on the pan. When the scale is
stable, take off the weight from the pan. The calibration finished.
(1) When the SWA1 is located in LOCK position, it can be revise the G value in 9 times..
It will display the last G value and all the historic data will be cleared in internal calibration.
(2) The other historic data will be cleared when the SWA1 is located in ADJ. And the G value
range are from 9.78031 to 9.83217.
Press one of [P1]-[P5] key to save the data after inputting the unit price.
1.2 P6 (Preset unit price method)
After do the steps 1, 2 of 1.1, press P6. If do to to key-in thedigit 00~79 within 2
seconds, the unit price will be saved into P6. If key-in the digit 00~79 within 2
seconds, the unit price will be save into the reserved location.
7
EXCELL PRECISION CO., LTD.
Unit Price Clear key, the screen shows the internal value.
Press T key
Press T key
8
EXCELL PRECISION CO., LTD.
0 9600 bits/second
1 4800 bits/second
2 2400 bits/second
3 1200 bits/second
9
EXCELL PRECISION CO., LTD.
Press M+ to print
NO. 001
N 10.005kg
T 0.500kg
U/P 50/kg
T/P 30
Press + to print
NO. 002
QTY 20pcs
U/P 10/pcs
T/P 200
Press MC to print
- 25 When recalled the returned good, it will
TOTAL NUMBER 002 print total price of returned goods.
AMOUNT 700 Otherwise, it will not.
Ater press CH , input PAY 1000
proper amounts, press CHANGE 300
MC key again to
print PAY and CHANGE
for needs
10
EXCELL PRECISION CO., LTD.
RS232 DATA FORMAT
Stable transmission or Continuous transmission
DATA ( 7 or 8 BYTE )
2D ( HEX ) = ( MINUS )
2B ( HEX ) = + (PLUS)
2E ( HEX ) = . ( DECIMAL POINT )
UNIT ( 23 or 4 BYTE )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C ( HEX ) ; 62 ( HEX )
tl.T = 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg = 68 ( HEX ) ; 6B ( HEX ) ; 67 ( HEX )
11
EXCELL PRECISION CO., LTD.
The Example of Transmission:
Data format for RS-232 continuous transmission are as below.
1. The gross weight (+0.876 kg) shows as below, after stable: (under no tare or pre-tare mode)
S T , G S , + 0 0 0 . 8 7 6 k g 0D 0A
2. The net weight (-1.568lb) shows as below, after unstable: (under tare or pre-tare mode)
U S , N T , - 0 0 1 . 5 6 8 l b 0D 0A
3. The net weight (+15 twg and 6.24 tl.T), after stable: (under tare or pre-tare mode)
S T , N T , + 1 5 . 0 6 . 2 4 t l . T 0D 0A
4. The net weight (+15 Catty and 6.24 hkg), after stable: (under tare or pre-tare mode)
S T , N T , + 1 5 . 0 6 . 2 4 h k g 0D 0A
12
EXCELL PRECISION CO., LTD.
0 ~ 9 Reading times 0 ~ 9
Default setting 2 times
0 1/4 d
1 1/2 d
2 3/4 d
31 d
13
EXCELL PRECISION CO., LTD.
0 The weighing unit remains * the set mode (not in conformity with laws and regulations)
* Prior setting mode: If a certain switching-on unit is set, this unit will be the one at
switching on.
If no unit is set, the unit at switching off last time will be the unit at
switching on
1 The weighing unit is as switching on is always kg (In conformity with laws and
regulations)
14
EXCELL PRECISION CO., LTD.
Linearity calibration
Linearity Calibrate must be done at 4 points. (The platter must be place on the on the scale.)
To skip the linearity calibration, please press 9 key to exit.
15
EXCELL PRECISION CO., LTD.
Press to record the starting point; then place the first 10kg weight.
Put the second weight. (eg.10 kg)
Press to record the second point; the add the second 10kg weight.
Put the third weight. (eg.10 kg)
The scale will count back to zero (or enter the specificiation setting mode). Linearity
calibration is completed.
Please take off all the weights before the scale counts back to zero zero.
16
EXCELL PRECISION CO., LTD.
CHAPTER 6 SPECIFICATION
CALIBRATION
Before switch the scale on, put the mini jumper of SWA1 on the main board to the position of
ADJ. Make sure that the platter is properly place on the scale, or there will be error between
E1 and E2.
Press the keys of MC , 1 and 7 at the same time to access the keyboard
After keyboard check, Press M+ key to start linearity calibration after keyboard check.
(Press T instead of M+ key for 14 key model.)
17
EXCELL PRECISION CO., LTD.
Calibration mode code 01(and above)
Specification calibration
If spec code 01 or above is set, eg. Input code 11 to show 1104000. (Refer to Appendix 11)
Press M+ key after inputting specification code. (Press T key for 14 key model.)
30kg weight (To input the different calibration value for different weight)
Put the enough weight accordingly, press M+ key and then show as follows:
The scale will back to zero. Please take all the weights off before backing to zero. Put
the weight to calibrate weight and specification. Please switch the MINI JUMPER of
SWA1 to LOCK position on PC board before powering on. The specification calibration is
finished.
18
EXCELL PRECISION CO., LTD.
Calibration mode code 00 (For example, 6.000kg/0.001kg/0.002kg, unit pirce and
total price are fixed on 2 digit)
Specification calibration
Input the full scale input advanced weight value Refer to remark 2
(not including 9d)
Press M+ key to read internal zero value as follow(Press T for 14 key model.):
After inputting, press the M+ key, the scale counts back to zero again. After calibration
setting, please put weight onto the platter to check if the calibrated weight is correct. If the
result is OK, switch off the scale first, then put the MINI JUMPER of SWA1 to the position of
LOCK, and the specification setting is completed. (Press T for 14 key model.)
19
EXCELL PRECISION CO., LTD.
Remark 1
(c): To set the number of decimal point of unit price and total price.
0 = no decimal point for unit price and total price.
1 = 1 decimal point for unit price and total price. key is 00
2 = 2 decimal point for unit price and total price. key for only one pricing unit.
3 = 3 decimal point for unit price and total price.
4 =2 decimal point for unit price, 0 decimal point for total price.
5 =2 decimal point for unit price, 1 decimal point for total price.
6 =2 decimal point for unit price, 2 decimal point for total price.
(d): The changes of odd amounts in addition to the round number of total price.
Press M+ to judge stabilization.
0 = Dont care whether stabilization for accumulation. Total price 1 One jump
1 = Dont care whether stabilization for accumulation. Total price 5 One jump
2 = Dont care whether stabilization for accumulation. Total price 10 One jump
3 = Dont care whether stabilization for accumulation. Total price 50 One jump
4 = To care whether stabilization for accumulation. Total price 1 One jump
5 = To care whether stabilization for accumulation. Total price 5 One jump
6 = To care whether stabilization for accumulation. Total price 10 One jump
7 = To care whether stabilization for accumulation. Total price 50 One jump
(e):
0 = no weight calibration; Press Z not to cancel tare when tarring.
20
EXCELL PRECISION CO., LTD.
Remark 2
(a) (b) (c) (d) (e) (f) (g)
(f)
0 = Input 5 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)
1 = Input 4 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)
2 = Input 5 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)
3 = Input 4 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)
4 = Input 5 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 3% FS; Zero range for turning on the scale: 3% FS)
5 = Input 4 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 3% FS; Zero range for turning on the scale: 3% FS)
6 = Input 5 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 3%FS; Zero range for turning on the scale: 3%FS)
7 = Input 4 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 3% FS;Zero range for turning on the scale: 3% FS)
(g)
0 = decimal point function ( . , oo , pricing unit ) , tare many times.
1 = no decimal point function ( . , oo , pricing unit ) , only tare one time.(Brazil)
2 = 6 groups of preset.
3 = 6 groups of preset; no decimal point function; only tare one time.(Brazil)
4 = no 6 groups of preset; 14 G key (BEST in Germany)
5 = 6 groups of preset; 20 key (BEST in Germany)
21
EXCELL PRECISION CO., LTD.
Remark 3
(d) Fixed 0
22
EXCELL PRECISION CO., LTD.
Remark 4
23
EXCELL PRECISION CO., LTD.
Power Consumption
30 mA (Indicator + Load Cell) About 140 hours
40 mA (Indicator + Load Cell + front display backlight) About 100 hours
50 mA (Indicator + Load Cell + front display backlight + rear display backlight)About 80 hours
Error Messages
OL The weight value is over full capacity + 9d.
E1 Zero value at +10% above TOTAL SPAN.
E2 Zero value at -10% below TOTAL SPAN.
E4 Unstable condition when the scale counts back to zero.
If the unstable time is over 10 seconds, please press 0 key to exit E4.
E6 If the internal value is over (350,000).
E7 If the internal value is below (80,000).
24
EXCELL PRECISION CO., LTD.
4 5 6 + MR 03 13 23 33 43
1 2 3 CH MC 01 11 21 31 41
.
0 Pricing CE Z T 02 12 22 32 42
unit
4 5 6 P2. P4 03 13 23 33 43
1 2 3 Z P5 01 11 21 31 41
0 CE T P6 02 12 22 32 42
25
EXCELL PRECISION CO., LTD.
ISN
00 10 20 02 30 43
03 13 23 12 33 31 41
01 11 21 22 32 32
35 PRESET K/B
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 PRESET
ISN
37 36 47 46 45 35 57 56 55 54
53 52 51 50 67 66 65 64 63 62
61 60 77 76 75 74 73 72 71 70
87 86 85 84 83 82
26
EXCELL PRECISION CO., LTD.
Single unit ( kg )(14 key )
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 1 1/3000
27
EXCELL PRECISION CO., LTD.
Single unit (kg) (German); weighing unit (kg); the decimal of unit price and total price is fixed in
2 digits.
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 4 1/3000
11 30kg/10g 0.00 kg 112000 4 1/3000
42 3kg/1g 0.000 kg 422000 4 1/3000
43 6kg/2g 0.000 kg 432000 4 1/3000
Single unit (kg) (German, 6 Preset); Pricing unit (kg); the decimal of unit price and total price is
fixed in 2 digits.
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 6 1/3000
11 30kg/10g 0.00 kg 112000 6 1/3000
42 3kg/1g 0.000 kg 422000 6 1/3000
43 6kg/2g 0.000 kg 432000 6 1/3000
Single unit (kg) (6 Preset AM,FD,SA,GR ); Pricing unit (kg); the decimal of unit price and total
price is fixed in 2 digits.
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 2 1/3000
11 30kg/10g 0.00 kg 112000 2 1/3000
42 3kg/1g 0.000 kg 422000 2 1/3000
43 6kg/2g 0.000 kg 432000 2 1/3000
Single unit (kg) (6 Preset AZ);Pricing unit (kg); the decimal of unit price and total price is fixed
in 2 digits.
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 9 1/3000
11 30kg/10g 0.00 kg 112000 9 1/3000
42 3kg/1g 0.000 kg 422000 9 1/3000
43 6kg/2g 0.000 kg 432000 9 1/3000
28
EXCELL PRECISION CO., LTD.
1 L 100 kg 1 L 200 kg
2 L 100 kg 2 L 200 kg
3 L 100 kg 3 L 200 kg
29
EXCELL PRECISION CO., LTD.
0 A N
1 B O
2 C P
3 D Q
4 E R
5 F S
6 G T
7 H U
8 I V
9 J W
K X
L Y
M Z
30
EXCELL PRECISION CO., LTD.
Input the unit price you need by pressing number key [0]-[9] in Unit Price
3 Press after inputing unit priceand then press any key of [P1]-[P5]the input unit
price will be recorded in the corresponding place
3.1 P6 Preset Unit Price Mode
After the above 2 of 1.1,press then press P6if the number key 00~79 are not input
within 2 secondsmemory P6 directly If the any group of number key 00~79 are input
within 2 secondsthe unit price will be recordedin the place you need.
Remark: When EEPROM is 24C02,it only has 6 groups of Preset Unit Price P1~P6.
When EEPROM is 24C04,it adds to P6 (00~79) 80 groups Preset Unit Price.
31
EXCELL PRECISION CO., LTD.
Input the unit price you need by pressing number key [0]-[9] in Unit Price
3 Press PRESET after inputing unit priceand then press any key of [01]-[35/30]the
input unit price will be recorded in the corresponding place among [01]~[35/30]
2. Calling Preset Unit Price Mode (01 ~ 35/30)
(Note A)
Preset function turn on / off (SWA1 should be adjusted to ADJ)
Hold keypad C,it will shows Preset tare state after 2 seconds.
If Preset tare state is on, the Preset tare function will be off and it will restart-up.
If it is on the state of on, it show PT YES; If off, it shows PT NO
(Note B)
If Preset function is on, general tare function can be used (But the premise should be CLEAR
preset tare value), Preset tare function and general tare function can not be used meanwhile.If
you want to use preset tare function, you should clear general tare value to use preset tare
function.
32
EXCELL PRECISION CO., LTD.
33
EXCELL PRECISION CO., LTD.
Germany best 16KEY 50PRESET settings are as follows: (EEPROM should be 24C04). Preset
PLU setting mode.
1. Hold PLUkey until it shows as follows: (Unit Price shows 0 and flickers )
Weight Unit Price Total
P nr. 0
Both the scale is empty and there is weight on are ok
2. Press number keys to input PLU Address you need (01~50),totally it can record 50 groups.
Weight Unit Price Total
P nr. 1
Both the scale is empty and there is weight on are ok
For example, if you want to store the 1st PLU, press number key 1, when the number key 1
rightmost flickers.
(if you want to store the 32rd PLU, press number key 32, when the number key 2 rightmost
flickers.)
When flickering, you can modify the value input by pressing key C.After 2 seconds,it stops
flickering when it shows Unit Price, entering into inputting PLU,.Total shows 0.00, the
number key 1 rightmost flickers as follows.
3. Entering into inputting PLU, it shows Unit Price, which can be set 5 digits at most.
Weight Unit Price Total
P nr. 32 0.00
Both the scale is empty and there is weight on are ok
If you want to store the unit price of 0.1, press number key 10, then the number rightmost
flickers.
(If you want to store the unit price of 123.45, press number key 12345), then the number
rightmost flickers as follows:
Weight Unit Price Total
P nr. 32 123.45
Both the scale is empty and there is weight on are ok
When flickering, you can modify the value input by pressing key C, After 2 seconds,it stops
flickering (After stoping flickering, you can modify the value input by pressing key C if you want),
At this time, if you want to input the next group of PLU , press PLU key once, then input the next
group of PLU.If finished , press F key.
B. Call PLU Mode
1. Input the PLU number you want.
For example, if you want to call the 32rd PLU, at weighing mode, press number key 32 then
press, PLU key once,you can callo the unit price you need,it shows as follows:
Press number key 32, it shows as follows:
Weight Unit Price Total
0.00 0.32 0.00
Both the scale is empty and there is weight on are ok
Then press PLU key,it shows as follows:
Weight Unit Price Total
0.00 123.45 0.00
Both the scale is empty and there is weight on are ok
34