You are on page 1of 35

EXCELL PRECISION CO., LTD.

Price Computing
Scale

Service Manual

EXCELL PRECISION CO., LTD. 2011. All rights reserved worldwide.

The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used except as
authorized by contract or other written permission. The copyright and the foregoing restriction
on reproduction and use extend to all media in which the information may be embodied.
EXCELL PRECISION CO., LTD.

TABLE OF CONTENTS

INSTRUCTIONS FOR USE .......................................................................................................................................................2

PREPARATIONS BEFORE USING .........................................................................................................................................2

CHAPTER 1 DISPLAY DESCRIPTIONS..............................................................................................................................3

CHAPTER 2 KEYPAD FUNCTIONS.....................................................................................................................................4

CHAPTER 3 OPERATION DESCRIPTION..........................................................................................................................4

3-1 TO CHECK INTERNAL VALUE .....................................................................................................................................4

3-2 BACKLIGHT OPERATION DESCRIPTION (OPTION) .............................................................................................4

3-3 SELECT PRICING UNIT..................................................................................................................................................5

3-4 FIX POWER-ON PRICING UNIT ...................................................................................................................................5

3-5 WEIGHT EXTERNAL CALIBRATION .........................................................................................................................6

3-6 FACTORY DEFAULT SETTING......................................................................................................................................6

3-7 G VALUE ADJUSTION .....................................................................................................................................................6

3-8 PRESET OPERATION DESCRIPTION..........................................................................................................................7

3-9 COMPOSITE KEY GENERAL FUNCTIONS................................................................................................................7

3-10 INTERNAL VALUE DISPLAY MODE ..........................................................................................................................8

CHAPTER 4 FUNCTION SETTING ......................................................................................................................................8

4-1 F1 RS-232 BAUD RATE............................................................................................................................................9


4-2 F2 TRANSMISSION MODE ( RS-232 ) ..................................................................................................................9
4-3 F3 STABILIZATION (ONE OF JUDGMENT CONDITIONS) READING TIMES ................................13
4-4 F4 STABILIZATION (ONE OF JUDGMENT CONDITIONS) RANGE ..................................................13
4-5 F5 CLEAR UNIT PRICE IMMEDIATELY AFTER ...................................................................................14

4-6 F6 SWITCHING-ON UNIT MODE SETTING ....................................................................................................14


CHAPTER 5 LINEARITY CALIBRATION ..........................................................................................................................15

CHAPTER 6 SPECIFICATION CALIBRATION.................................................................................................................17

CHAPTER 7 POWER DESCRIPTION ................................................................................................................................24

CHAPTER 8 MODEL SELECTION SETTING...................................................................................................................25

1
EXCELL PRECISION CO., LTD.
APPENDIX 1 SPECIFICATION SETTING TABLE ...........................................................................................................26

APPENDIX 2 LINEARITY CALIBRATION TABLE ...........................................................................................................29

APPENDIX 3 7-SEGMENT DISPLAY CHARACTERS ....................................................................................................30

APPENDIX 4 6 PRESET OPERATING DESCRIPTION .................................................................................................31

APPENDIX 5 35/30 PRESET OPERATING DESCRIPTION...........................................................................................32

Thank you for purchasing EXCELL Price


Computing Scale. In order to operate smoothly,
to last the durability, and to reduce the chance
of breakdown for this product, please read this
Manual carefully.

INSTRUCTIONS FOR USE


1. In order to prevent the scale from dusta and static electricity, please fix the dustproof
cover on the scale with double-sided adhesive.
2. The scale should not be drenched by rain or water. (If it gets wet carelessly, please
wipe it dry with a cloth. If its operation is abnormal, please send it to our distributor for
service. )
3. Please keep the scale in a cool and dry place. Do not store at high temperatures or
damp places.
4. Please keep the scale clean and free from insect infestation.
5. To avoid impact and it is to be used under designated pressure (the weight put on the
platter can not exceed the maximum capacity of the scale).
6. If the scale is not going to be used for some time, please clean it and store it in a plastic
bag in dry condition. A desiccant sachet may be included to prevent moisture build up.
The scale should be recharged every 3 months to prevent failure of the internal
rechargeable battery.
7. The commodity should be placed in the center of platter for accurate weighing. The
dimension of the weighted commodity should not exceed the dimension of platter.
8. Please release the protection screw 4 before weighing.
9. Any suggestion for product is warmly welcome.

PREPARATIONS BEFORE USING


1. Put the scale on a firm level surface free for accurate weight readings. Adjust the four
leveling feet to get the leveling bubble at the centre of circle.
2. Scale must be used under a stable temperature and stable air flow. Avoid direct sunlight

2
EXCELL PRECISION CO., LTD.
onto the scale or near the exhaust port of ventilating system.
3. Scale must be used under individual socket to avoid the interference of other electric
appliances.
4. Remove any weight that might be on the platter before the scale is switched on.

5. Please note that when or symbol appears on the screen, the scale needs to

be recharged.

CHAPTER 1 DISPLAY DESCRIPTIONS


Weight kg Unit Price $/kg To t a l Price $
Z  M+ 

T  . . . . . . . . . . . . . . . . .

Display Column

1. Weight
Total 6 digits. To display the weight on platter. The left digit is able to display the negative
symbol.

2. Unit Price
Total 5 digits. To display unit price of objects on the platter. The demical point floats two
digits.

3. Total Price
Total 6 digits. To display total price of the objects on platter or the accumulation.

Symbol Display

1. Z : Zero indication.
2. T : Tare indication.
3. M+ : Accumulation indication.

4. : Low battery.

3
EXCELL PRECISION CO., LTD.

CHAPTER 2 KEYPAD FUNCTIONS


6 preset
7 8 9 P1 P2
7 8 9 0 P1 P2 P3
4 5 6 P3 P4
4 5 6 Enter P4 P5 P6
1 2 3 Z P5
1 2 3 CE Z TARE
0 Enter CE T P6

Remark:
The keypad,which is for 6preset, has two kinds of shape.One is square (above left), the other
oblong (above right).

0 ~ 9 : Number key. Press the keys to input the numbers (0 ~ 9) and to set unit price.
CE : Press the key to clear the old unit price and then input the new one if you would like to
change the unit price (If the unit price has been input for 3 seconds, you can input the
new one immediately.).
 Recall function:
When Unit Price shows 0, press CE to recall the accumulation total times and total
amounts.
P1 ~ P5 : Five groups memory function descriptions
P6 : memory function descriptions (corresponding to 00-79 totally memory 80groups)
T : Press the key to deduct the containers weight and the symbol in Weight will appear.
Z : Zero function.

CHAPTER 3 OPERATION DESCRIPTION


3-1 To Check Internal Value
Press Zero key, when the display show ,,then, press CE key
immediately. The display will show internal value. Pres 0 to exit the internal value
mode and return to the weighing mode.

3-2 Backlight Operation Description (Option)


<Method 1>

Press Zero key, the display will show ,then press 4 key right
away. It means auto backlight mode. It is auto backlight mode.

4
EXCELL PRECISION CO., LTD.
Press Zero key, the display will show , then press 5 key right
away. It means without backlight mode.
It is backlight off mode.
<Method 2>

Press 0 key for 2 seconds, the beeper will have beep three times.
The scale will change to backlight mode auto backlight mode or backlight off mode.
Auto backlight mode
When there is a weight on the pan which weight is over 10d or pressing any keys, the
backlight will be on. After back to zero for 10 desonds (the weight is under 10d,),
backlight will be off
The scale will be memorized power off backlight mode.

3-3 Select Pricing Unit

n Press 00 key two times, the display will show the current priceing unit.
z3 kg kg 3
.

o Using digit key 1 ~ 4 key to select pricing units. The scale will be back to weighing &
price mode. The display will show the symbol indication for the request priceing unit.
1 kg 2 100g 3 twg 4 tl.T
 Press 1 ~ 6 to select pricing units of Hongkong.
1 kg 2 100g 3 twg
4 tl.T 5 lb 6 oz
When select the price unit lb, the displaying will show three symbols 3.
When select the price unit oz, the displaying will not show any symbol 3 .

3-4 Fix Power-on Pricing Unit


1. To cancel power on pricing unit operation procedure
Press Zero key, the display will show , then press 7 key, the
scale cancels the requested power on pricing unit.

 After cancel the power on pricing unit, the scale memorizes the last power off unit.
The last pricing unit shows on the display

2. To fix power-on pricing unit operation procedure


Using 00 key to select the power on pricing unit.

Press Zero key, the display will show , then press 8 key, the

5
EXCELL PRECISION CO., LTD.
scale will fix as the request power on pricing unit.
 According to the above operation procedure to fix the power on pricing unit, no matter what
pricing unit is used at the operation procedure or power off pricing unit. The power on unit is
fixed as the setting.
 If youd like to change power on pricing unit, please follow the working procedures as
follows:
1. Enter to the power on pricing unit working procedure.
2. Cancel the power on pricing unit.
3. Enter the power on pricing unit working procedure.
4. Reset to fix another power on pricing unit.

3-5 Weight External Calibration

Operation mode 1. Make sure the scale backs to zero and keeps in kg mode.

2. Press MC key and do not release, the then press . key to show
, the weight display . kg .
3. Release two keys.
4. Key-in pre-calibration weight, the display will show pre-calibration of
weight value in flash. Place full weight on the pan. When the scale is
stable, take off the weight from the pan. The calibration finished.

3-6 Factory Default Setting


Return to the factory setting, please press MC key and CE key.
Operation : Press MC key and do not release, then press CE key. After
buzzer beep sound, release two keys. The scale will return to factory setting.

3-7 G Value Adjustion


(Please dont do it when doing internal calibration)
Operation
1. Press 0 key and do not release, and then power on to enter int G value adjustion
mode.
2. Press T key to search the historic G value data.
3. Press M+ key to set and confirm G value. ( Press Z key for model of 14 keys)
4. Press 0 ~ 9 key to input the value.
6
EXCELL PRECISION CO., LTD.

5. Press CE key to shift the flashing digit one space to left.


6. Press key to exit.

(1) When the SWA1 is located in LOCK position, it can be revise the G value in 9 times..
It will display the last G value and all the historic data will be cleared in internal calibration.
(2) The other historic data will be cleared when the SWA1 is located in ADJ. And the G value
range are from 9.78031 to 9.83217.

3-8 Preset Operation Description


1. Preset Method
1.1 Preset unit price (P1-P5 pre-set method)

Weight Unit Price Total Price


0.000 0.00 0.00
The weight on the platter or not.
0.000 1.23 0.00

Press 0 - 9 key to input the reserved unit price in Unit Price.

Press one of [P1]-[P5] key to save the data after inputting the unit price.
1.2 P6 (Preset unit price method)
After do the steps 1, 2 of 1.1, press P6. If do to to key-in thedigit 00~79 within 2
seconds, the unit price will be saved into P6. If key-in the digit 00~79 within 2
seconds, the unit price will be save into the reserved location.

2. Calling the preset unit price method:


2.1 Calling the preset unit price (P1-P5)

Weight Unit Price Total Price


0.000 0.00 0.00
The weight on the platter or not.
0.000 1.23 0.00
Press[P1]-[P5] to recall the unit price.
2.2 P6 Calling the preset unit price method
Press P6 and if do not key-in the digit 00~79 within 2 seconds, the unit price of P6 will
be recalled. And if key-in any digit 00~79 within 2 seconds, the unit price will be
recalled.

3-9 Composite Key General Functions


LOCK Zone ( Put SWA1 on ADJ position on the PC board )

Press CE + 2 keys at the same time External calibration unavailable

7
EXCELL PRECISION CO., LTD.

Press CE + 3 keys at the same time External calibration available

Press CE + 4 keys at the same time Accumulation without judging stable

Press CE + 5 keys at the same time Accumulation with judging stable

Press CE + 7 keys at the same time To select Keyboard ( 20key )

Press CE + 8 keys at the same time To select Keyboard ( 14key Germany


BEST )

Press CE + 9 keys at the same time To select Keyboard ( 14key )

Press CE + 0 keys at the same time To select Keyboard ( 16key Germany


BEST )

3-10 Internal Value Display Mode


Press Zero key,when WEIGHT shows ,then press

Unit Price Clear key, the screen shows the internal value.

Press 0 key to exit internal value mode

CHAPTER 4 FUNCTION SETTING


LOCK section (It has to adjust SWA1 to ADJ position on PCB board)
Press MC key do not release, and then power on to enter into function setting mode.

Weight kg Unit Price $/kg Total Price $

Press T key

Weight kg Unit Price $/kg Total Price $

Press T key

8
EXCELL PRECISION CO., LTD.

4-1 F1 RS-232 Baud Rate

Weight kg Unit Price $/kg Total Price $

Using 0,1,2,3 keys to choose 0,1,2,3 in order

0 9600 bits/second
1 4800 bits/second
2 2400 bits/second
3 1200 bits/second

Press T key enter the next setting mode.


Press M+ key to save setting values. The scale will count backwards to zero and
back to weight mode.

RS-232 Interface Format


I . Mode : UART Signal of EIA-RS0232 C
II . Format :
1. Baud rate : 1 200, 2 400, 4 800, 9 600 bits/second
2. Data bits : 8 bits
3. Parity bit : None
4. Stop bits : 1 bit
5. Code : ASCII (Exchange code of American standard)

Start bit Data bits Stop bit

4-2 F2 Transmission Mode ( RS-232 )

Weight kg Unit Price $/kg Total Price $

Press number key 0,1,2,3 to choose 0,1,2,3 in order

9
EXCELL PRECISION CO., LTD.

0 Press M+ and MC key transmit RS232


1 Continuous transmission (only RS-232)
2 Stable transmission (only RS-232)
3 Power off RS-232

Press T to go to next setting mode.


Press M+ to save setting values. The scale will count backwards to zero and back to
weight mode.

When F2 setting is 0 , the RS232 format is as below.

Press M+ to print
NO. 001
N 10.005kg
T 0.500kg
U/P 50/kg
T/P 30

Press + to print
NO. 002
QTY 20pcs
U/P 10/pcs
T/P 200

Press MC to print
- 25 When recalled the returned good, it will
TOTAL NUMBER 002 print total price of returned goods.
AMOUNT 700 Otherwise, it will not.
Ater press CH , input PAY 1000
proper amounts, press CHANGE 300
MC key again to
print PAY and CHANGE
for needs

10
EXCELL PRECISION CO., LTD.
RS232 DATA FORMAT
Stable transmission or Continuous transmission

(1) Weight unit is g.


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 g

HEAD , HEAD , DATA UNIT CR LF


(2) Weight unit is kg/lb
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 kg/lb

HEAD , HEAD , DATA UNIT CR LF


(3) Weight unit is g, lb or oz.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 twg

HEAD , HEAD , DATA UNIT CR LF


(4) Weight unit is Catty.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Catty

HEAD , HEAD , DATA UNIT CR LF

HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES )


OL - Overload , Under load
ST - Display is Stable NT - NET Mode
US - Display is Unstable GS - GROSS Mode

DATA ( 7 or 8 BYTE )
2D ( HEX ) = ( MINUS )
2B ( HEX ) = + (PLUS)
2E ( HEX ) = . ( DECIMAL POINT )

UNIT ( 23 or 4 BYTE )
kg = 6B ( HEX ) ; 67 ( HEX )
lb = 6C ( HEX ) ; 62 ( HEX )
tl.T = 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg = 68 ( HEX ) ; 6B ( HEX ) ; 67 ( HEX )

11
EXCELL PRECISION CO., LTD.
The Example of Transmission:
Data format for RS-232 continuous transmission are as below.
1. The gross weight (+0.876 kg) shows as below, after stable: (under no tare or pre-tare mode)
S T , G S , + 0 0 0 . 8 7 6 k g 0D 0A

HEAD , HEAD , DATA UNIT C LF

2. The net weight (-1.568lb) shows as below, after unstable: (under tare or pre-tare mode)
U S , N T , - 0 0 1 . 5 6 8 l b 0D 0A

HEAD , HEAD , DATA UNIT C LF

3. The net weight (+15 twg and 6.24 tl.T), after stable: (under tare or pre-tare mode)
S T , N T , + 1 5 . 0 6 . 2 4 t l . T 0D 0A

HEAD , HEAD , DATA UNIT C LF

4. The net weight (+15 Catty and 6.24 hkg), after stable: (under tare or pre-tare mode)
S T , N T , + 1 5 . 0 6 . 2 4 h k g 0D 0A

HEAD , HEAD , DATA UNIT C LF

12
EXCELL PRECISION CO., LTD.

4-3 F3 Stabilization (One of judgment conditions)


Reading Times

Weight Unit weight Quantity

Press number key from 0 to 9 to select 0~9

0 ~ 9 Reading times 0 ~ 9
Default setting 2 times

Press T to go to next setting mode.


Press M+ to save setting values. The scale will count backwards to zero and back to
weighing mode from exiting setting mode.

4-4 F4 Stabilization (One of judgment conditions)


Range

Weight Unit weight Quantity

Press number key 0,1,2,3 to select 0 ~ 3

0 1/4 d
1 1/2 d
2 3/4 d
31 d

Press T to go to next setting mode.


Press M+ to save setting values. The scale will count backwards to zero and back to
weighing mode from exiting setting mode.

13
EXCELL PRECISION CO., LTD.

4-5 F5 Clear Unit Price Immediately After

Weight Unit weight Quantity

Press number key 0 ,1 to select 0 or 1

0 Unit price reserved.


1 Clear unit price immediately.
(Press to clear unit price immediately in accumulation mode and change mode.

Press T key to enter the next setting mode.


Press M+ key to save setting values and exit the setting mode. The scale will count
backwards to zero and return to the weighing mode from exiting setting mode.

4-6 F6 Switching-on Unit Mode Setting

Weight Unit weight Quantity

Use thenumber key 0 ,1 to select a parameter from 0 or 1

0 The weighing unit remains * the set mode (not in conformity with laws and regulations)
* Prior setting mode: If a certain switching-on unit is set, this unit will be the one at
switching on.
If no unit is set, the unit at switching off last time will be the unit at
switching on
1 The weighing unit is as switching on is always kg (In conformity with laws and
regulations)

Press T key to enter the next setting mode.


Press M+ key to save setting values and exit the setting mode. The scale will count
backwards to zero and return to the weighing mode.

14
EXCELL PRECISION CO., LTD.

CHAPTER 5 LINEARITY CALIBRATION


Before switch the scale on, put the MINI JUMPER of SWA1 on ADJ position.
Press MC key, 1 key and 6 key at the same time to access the keyboard
selection model. (Press T , 1 and 6 at the same time for 14key model.)
Please enter into Unit price and Total price to display the initial program version number for
new scales.

Weight Unit price Total price


XXXXX XXX

20 key Program version number Sub-version


 Press 7 to show for 20 key function use.
Press 8 to show for 14 key function in German.
Press 9 to show for 14 key in Brazil and Switzerland.
After choosing the keyboard mode, press 0 key to enter into linearity calibration mode.

Linearity calibration

Linearity Calibrate must be done at 4 points. (The platter must be place on the on the scale.)
To skip the linearity calibration, please press 9 key to exit.

The internal value must be between 80 000 to 350 000,with platter on


Means between range of E6 and E7.

Example : Full capacity=30kg , there are 3 sections 10 kg,10kg,10kg

Weight Unit price Total price


XXXXXX

The initial point Internal value with the platter

15
EXCELL PRECISION CO., LTD.

Press to input the initial value in the memory.


Put the first weight. (eg.10 kg)

Weight Unit price Total price


XXXXXX

The first linearity calibration


Put on the first weight (10kg) Internal value after first 10kg weight is placed

Press to record the starting point; then place the first 10kg weight.
Put the second weight. (eg.10 kg)

Weight Unit price Total price


XXXXXX

The second linearity calibration


Put on the second weight (10kg) Internal value after second weight (20kg) is added.

Press to record the second point; the add the second 10kg weight.
Put the third weight. (eg.10 kg)

Weight Unit price Total price


XXXXXX

The third linearity calibration


Put on the third weight (10kg) Internal value after the third weight (30kg) is added.

Press to record the third weight value.


The scale will becomes stable as follows.

Weight Unit price Total price


.

The scale will count back to zero (or enter the specificiation setting mode). Linearity
calibration is completed.
Please take off all the weights before the scale counts back to zero zero.

16
EXCELL PRECISION CO., LTD.

CHAPTER 6 SPECIFICATION
CALIBRATION
Before switch the scale on, put the mini jumper of SWA1 on the main board to the position of
ADJ. Make sure that the platter is properly place on the scale, or there will be error between
E1 and E2.

Press the keys of MC , 1 and 7 at the same time to access the keyboard

selection mode. (Press T , 1 and 7 for 14 key model.)


If youd like to show the initial program version number, please press the keys of Unit price
and Total price.

Weight Unit price Total price


XXXXX XXX

20 key Program version number Sub-version

 Input 7 and the weight show for 20-key keyboard mode


Input 8 and the weight show for 14-key keyboard model applicable to
Germany.
Input 9 and the weight show for 14-key keyboard model application to
Brazil and Switzerland.
After choosing the keyboard mode, press 0 to access the keyboard testing mode.

Keyboard check mode

Weight Unit price Total price


XX XXXXXX XXXXXX

Keyboard internal Internal value at full capacity Internal value


code (Shows 0 if not be calibrated)

After keyboard check, Press M+ key to start linearity calibration after keyboard check.
(Press T instead of M+ key for 14 key model.)

17
EXCELL PRECISION CO., LTD.
Calibration mode code 01(and above)
Specification calibration

Weight Unit price Total price

Input 01 key in specification code fixed


refer to Appendix 1 (refer to remark 1)

If spec code 01 or above is set, eg. Input code 11 to show 1104000. (Refer to Appendix 11)
Press M+ key after inputting specification code. (Press T key for 14 key model.)

Weight Unit price Total price

30kg weight (To input the different calibration value for different weight)

Put the enough weight accordingly, press M+ key and then show as follows:

Weight Unit price Total price


.

 The scale will back to zero. Please take all the weights off before backing to zero. Put
the weight to calibrate weight and specification. Please switch the MINI JUMPER of
SWA1 to LOCK position on PC board before powering on. The specification calibration is
finished.

18
EXCELL PRECISION CO., LTD.
Calibration mode code 00 (For example, 6.000kg/0.001kg/0.002kg, unit pirce and
total price are fixed on 2 digit)
Specification calibration

Weight Unit price Total price

Input 00 key in specification code


(refer to remark 1) keep

Calibration mode code inputs 00.


Press M+ after inputting the calibration code. (Press T for 14 key model.)

Weight Unit price Total price

Input the full scale input advanced weight value Refer to remark 2
(not including 9d)

After press M+ (Press T for 14 key model.)

Weight Unit price Total price

Input the full scale +9d/ 60d refer to remark 3


Input weight value for
The first span and the second span

Press M+ key to read internal zero value as follow(Press T for 14 key model.):

Weight Unit price Total price

6kg weight (different calibration value for different weight)

After inputting, press the M+ key, the scale counts back to zero again. After calibration
setting, please put weight onto the platter to check if the calibrated weight is correct. If the
result is OK, switch off the scale first, then put the MINI JUMPER of SWA1 to the position of
LOCK, and the specification setting is completed. (Press T for 14 key model.)

19
EXCELL PRECISION CO., LTD.
Remark 1

(a) (b) (c) (d) (e) (f) (g)


(a),(b) : calibration mode code.
0 0 Normal calibration mode (When the desired spec. is not found in Appendix 1.)
0 1 (and above 0 1) refer to Appendix 1.

(c): To set the number of decimal point of unit price and total price.
0 = no decimal point for unit price and total price.
1 = 1 decimal point for unit price and total price. key is 00
2 = 2 decimal point for unit price and total price. key for only one pricing unit.
3 = 3 decimal point for unit price and total price.

4 =2 decimal point for unit price, 0 decimal point for total price.
5 =2 decimal point for unit price, 1 decimal point for total price.
6 =2 decimal point for unit price, 2 decimal point for total price.

(d): The changes of odd amounts in addition to the round number of total price.
Press M+ to judge stabilization.

0 = Dont care whether stabilization for accumulation. Total price 1 One jump
1 = Dont care whether stabilization for accumulation. Total price 5 One jump
2 = Dont care whether stabilization for accumulation. Total price 10 One jump
3 = Dont care whether stabilization for accumulation. Total price 50 One jump
4 = To care whether stabilization for accumulation. Total price 1 One jump
5 = To care whether stabilization for accumulation. Total price 5 One jump
6 = To care whether stabilization for accumulation. Total price 10 One jump
7 = To care whether stabilization for accumulation. Total price 50 One jump
(e):
0 = no weight calibration; Press Z not to cancel tare when tarring.

1 = weight calibration; Press Z not to cancel tare when tarring.

2 = no weight calibration; Press Z to cancel tare when tarring.

3 = weight calibration; Press Z to cancel tare when tarring.

20
EXCELL PRECISION CO., LTD.

Remark 2
(a) (b) (c) (d) (e) (f) (g)
(f)
0 = Input 5 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)

1 = Input 4 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)

2 = Input 5 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)

3 = Input 4 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 2% FS; Zero range for turning on the scale: 10% FS)

4 = Input 5 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 3% FS; Zero range for turning on the scale: 3% FS)

5 = Input 4 decimal point for unit price. The unit price isnt automatically cleared.
(Zero tracking and re-zero range: 3% FS; Zero range for turning on the scale: 3% FS)

6 = Input 5 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 3%FS; Zero range for turning on the scale: 3%FS)

7 = Input 4 decimal point for unit price. The unit price is automatically cleared.
(Zero tracking and re-zero range: 3% FS;Zero range for turning on the scale: 3% FS)
(g)
0 = decimal point function ( . , oo , pricing unit ) , tare many times.
1 = no decimal point function ( . , oo , pricing unit ) , only tare one time.(Brazil)
2 = 6 groups of preset.
3 = 6 groups of preset; no decimal point function; only tare one time.(Brazil)
4 = no 6 groups of preset; 14 G key (BEST in Germany)
5 = 6 groups of preset; 20 key (BEST in Germany)

bit 0: 0 = decimal point function ( . , oo , pricing unit ) , tare many times


1 = no decimal point function ( . , oo , pricing unit ) , only tare one time.(Brazil)

bit 1: 0 = no 6 groups of preset


1 =6 groups of preset (20key will replace M+, MR, MC, CH, QTY, +keys)
bit 2: 0 = Press Z or T key, the weight column - - - - - - ,
When oL appears, the weight column will display oL
1 = Press Z or T key, the weight column - - Z - - , - - t - -, (BEST in Germany)
When oL appears, the weight column will display

21
EXCELL PRECISION CO., LTD.

Remark 3

(a) (b) (c) (d)


(a) Its for dual range model. The second range of rounding setting is 0 or 1 or 2 or 5 jump.
If it is single range function, please input the first section division.

(b) The decimal point at weight display.


0= the decimal point fixed as 0.
1= the decimal point fixed as 1.
2= the decimal point fixed as 2.
3= the decimal point fixed as 3.
4= the decimal point fixed as 4.
7= twg
8=tl.T
9=dwt

(c) weight displays unit.


0= kg
1= g
2= lb
3= not display twg or hkg

(d) Fixed 0

22
EXCELL PRECISION CO., LTD.

Remark 4

(a) (b) (c) (d)

(a): First division (0,1,2,5)


(b): When pricing unit is kg, g and lb.
Display: 0= kg
1=100g
When pricing unit is twg and tl.T.
Display: twg,tl. T ,cent
1 = 0. 0.00
2 = 0. 0.0
3 = 0. 0

(c): Reserved (only 0)

(d): The quantities of pricing unit


0 = one pricing unit
1 = two pricing units
2 = three pricing units
3 = four pricing units (Taiwan)
4 = five pricing units
5 = six pricing units (HK)

Input 0 One pricing unit.


Input 1 Two pricing units. To redo the above operation.

23
EXCELL PRECISION CO., LTD.

CHAPTER 7 POWER DESCRIPTION


Power Selection (For different models)
1. 6 V / 4 Ah Rechargeable battery
2. 110 / 220 V 15 % AC Main power

Recharge Voltage(For different models)


1. AC 110 V +10% , -15%
2. AC 220 V +10% , -15%

Power Consumption
30 mA (Indicator + Load Cell) About 140 hours
40 mA (Indicator + Load Cell + front display backlight) About 100 hours
50 mA (Indicator + Load Cell + front display backlight + rear display backlight)About 80 hours

Low Power Alarm


When the ( ) symbol keeps flashing on the left down corner of the display, it need
charging.
 The indicator will turn off automatically after 5 ~ 10 hours (approximately 1 ~ 2 hours
with backlight on), when the low battery warning symbol shows up. The indicator must
be fully charged, before operating again.
 When the low battery warning symbol shows up, please recharge the indicator
immediately for fear of weight instability.

Error Messages
OL The weight value is over full capacity + 9d.
E1 Zero value at +10% above TOTAL SPAN.
E2 Zero value at -10% below TOTAL SPAN.
E4 Unstable condition when the scale counts back to zero.
If the unstable time is over 10 seconds, please press 0 key to exit E4.
E6 If the internal value is over (350,000).
E7 If the internal value is below (80,000).

24
EXCELL PRECISION CO., LTD.

CHAPTER 8 MODEL SELECTION SETTING


Before switching the scale on, put the MINI JUMPER of SWA1 on ADJ position.
Press M+ key to enter the setting mode with 20key price scale.

20key ,14key,16key (International Edition)


After switching the scale on,press M+ key and do not release and enter it after finishing
counting down.
Weight Unit Price Total Price

Press the number key 0 , then jump to P3 to continue settings.

14 key (AM model) German BEST


7 8 9 Z 00 10 20 30
4 5 6 01 11 21

1 2 3 03 13 23
0 00 CE T 02 12 22

14 key (AM model) Brazil, Swizerland and Avery (America, Canada)


7 8 9 00 10 20
4 5 6 01 11 21
Z
1 2 3 03 13 23 33
0 . CE T 02 12 22

20 key (AM,GE model)


7 8 9 QTY M+ 00 10 20 30

4 5 6 + MR 03 13 23 33 43

1 2 3 CH MC 01 11 21 31 41
.
0 Pricing CE Z T 02 12 22 32 42
unit

20 key (AM, GE, FD,SA model) including 6 preset


7 8 9 P1 P3 00 10 20 30

4 5 6 P2. P4 03 13 23 33 43

1 2 3 Z P5 01 11 21 31 41

0 CE T P6 02 12 22 32 42

25
EXCELL PRECISION CO., LTD.

20key(AZ model) including 6 preset


7 8 9 0 P1 P2 P3
4 5 6 P4 P5 P6
1 2 3 CE Z T


ISN
00 10 20 02 30 43
03 13 23 12 33 31 41
01 11 21 22 32 32

35 PRESET K/B
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 PRESET

ISN
37 36 47 46 45 35 57 56 55 54
53 52 51 50 67 66 65 64 63 62
61 60 77 76 75 74 73 72 71 70
87 86 85 84 83 82

APPENDIX 1 SPECIFICATION SETTING


TABLE
Dual units ( kg & lb ) (14key approved in America and Canada)
Specification
Press T + 1 + 7 External
Code Zero Zero
kg lb to input resolution
display display
01 3.000 kg / 0.001 kg 0.000 kg 6.000 lb / 0.002 lb 0.000 lb 012003 0 1/3000
02 6.000 kg / 0.002 kg 0.000 kg 12.000 lb / 0.005 lb 0.000 lb 022003 0 1/3000
03 15.000 kg / 0.005 kg 0.000 kg 30.00 lb / 0.01 lb 0.00 lb 032003 0 1/3000
04 30.00 kg / 0.01 kg 0.00 kg 60.00 lb / 0.02 lb 0.00 lb 042003 0 1/3000
05 60.00 kg / 0.02 kg 0.00 kg 120.00 lb / 0.05 lb 0.00 lb 052003 0 1/3000
06 150.00 kg / 0.05 kg 0.00 kg 300.0 lb / 0.1 lb 0.0 lb 062003 0 1/3000
07 300.0 kg / 0.1 kg 0.0 kg 600.0 lb / 0.2 lb 0.0 lb 072003 0 1/3000

Laws and regulations in America&Canada is the parameter 3.

26
EXCELL PRECISION CO., LTD.
Single unit ( kg )(14 key )
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 1 1/3000

11 30kg/10g 0.00 kg 112000 1 1/3000

12 60kg/20g 0.00 kg 122000 1 1/3000

13 150kg/50g 0.00 kg 132000 1 1/3000

14 300kg/100g 0.0 kg 142000 1 1/3000


0kg-6kg/2g
16
6kg-15kg/5g
0.000 kg 162000 1
0kg-15kg/5g
17
15kg-30kg/10g
0.000 kg 172000 1
0kg-30kg/10g
18
30kg-60kg/20g
0.00 kg 182000 1
0kg-150kg/50g
20
150kg-300kg/100g
0.00 kg 202000 1

Laws and regulations in Brizil is the parameter 1.

Single unit ( g ), weighing unit (100g)


Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
08 15000g/5g 0g 080000 0
09 15000g/2g 0g 090000 0
15 30000g/5g 0g 150000 0
19 30000g/10g 0g 190000 0

27
EXCELL PRECISION CO., LTD.

Single unit (kg) (German); weighing unit (kg); the decimal of unit price and total price is fixed in
2 digits.
Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 4 1/3000
11 30kg/10g 0.00 kg 112000 4 1/3000
42 3kg/1g 0.000 kg 422000 4 1/3000
43 6kg/2g 0.000 kg 432000 4 1/3000

Single unit (kg) (German, 6 Preset); Pricing unit (kg); the decimal of unit price and total price is
fixed in 2 digits.

Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 6 1/3000
11 30kg/10g 0.00 kg 112000 6 1/3000
42 3kg/1g 0.000 kg 422000 6 1/3000
43 6kg/2g 0.000 kg 432000 6 1/3000

Single unit (kg) (6 Preset AM,FD,SA,GR ); Pricing unit (kg); the decimal of unit price and total
price is fixed in 2 digits.

Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 2 1/3000
11 30kg/10g 0.00 kg 112000 2 1/3000
42 3kg/1g 0.000 kg 422000 2 1/3000
43 6kg/2g 0.000 kg 432000 2 1/3000

Single unit (kg) (6 Preset AZ);Pricing unit (kg); the decimal of unit price and total price is fixed
in 2 digits.

Zero External
Code Specification Press MC + 1 + 7
display resolution
to input
10 15kg/5g 0.000 kg 102000 9 1/3000
11 30kg/10g 0.00 kg 112000 9 1/3000
42 3kg/1g 0.000 kg 422000 9 1/3000
43 6kg/2g 0.000 kg 432000 9 1/3000

28
EXCELL PRECISION CO., LTD.

APPENDIX 2 LINEARITY CALIBRATION


TABLE
3 kg 6 kg 12,15 kg
5
1 L 1 kg 1 L 2 kg 1 L
kg
5
2 L 1 kg 2 L 2 kg 2 L
kg
5
3 L 1 kg 3 L 2 kg 3 L
kg
24,30 kg 60 kg 120,150 kg
50
1 L 10 kg 1 L 20 kg 1 L
kg
50
2 L 10 kg 2 L 20 kg 2 L
kg
50
3 L 10 kg 3 L 20 kg 3 L
kg
240,300 kg 600 kg

1 L 100 kg 1 L 200 kg

2 L 100 kg 2 L 200 kg

3 L 100 kg 3 L 200 kg

29
EXCELL PRECISION CO., LTD.

APPENDIX 3 7-SEGMENT DISPLAY


CHARACTERS

Number Display Letter Display Letter Display

0 A N

1 B O

2 C P

3 D Q

4 E R

5 F S

6 G T

7 H U

8 I V

9 J W

K X

L Y

M Z

30
EXCELL PRECISION CO., LTD.

APPENDIX 4 6 PRESET OPERATING


DESCRIPTION
6 PRESET Operating Description(Depending on different models)
3. Preset Mode
1.1 Preset Unit Price (P1-P5 Preset mode)

Weight Unit Price Total


1 0.000 0.00 0.00
Both the scale is empty and there is weight on are ok

2 0.000 1.23 0.00

Input the unit price you need by pressing number key [0]-[9] in Unit Price

3 Press after inputing unit priceand then press any key of [P1]-[P5]the input unit
price will be recorded in the corresponding place
3.1 P6 Preset Unit Price Mode
After the above 2 of 1.1,press then press P6if the number key 00~79 are not input
within 2 secondsmemory P6 directly If the any group of number key 00~79 are input
within 2 secondsthe unit price will be recordedin the place you need.

4. Calling Preset Unit Price Mode


4.1 Calling Preset Unit Price (P1-P5)

Weight Unit Price Total


1 0.000 0.00 0.00
Both the scale is empty and there is weight on are ok

2 0.000 1.23 0.00


Press [P1]-[P5] you can call input unit price
4.2 P6 Calling Preset Unit Price
After pressing P6if the number key 00~79 are not input within 2 secondsthe unit price of
P6 is called directly If the any group of number key 00~79 are input within 2 seconds, the
unit price of this group is called.

Remark: When EEPROM is 24C02,it only has 6 groups of Preset Unit Price P1~P6.
When EEPROM is 24C04,it adds to P6 (00~79) 80 groups Preset Unit Price.

31
EXCELL PRECISION CO., LTD.

APPENDIX 5 35/30 PRESET OPERATING


DESCRIPTION
35 PRESET Operating Description(Depending on different models)
1. Preset Mode
1.1 Preset Unit Price (01 ~ 35/30)

Weight Unit Price Total


1 0.000 0.00 0.00
Both the scale is empty and there is weight on are ok

2 0.000 1.23 0.00

Input the unit price you need by pressing number key [0]-[9] in Unit Price

3 Press PRESET after inputing unit priceand then press any key of [01]-[35/30]the
input unit price will be recorded in the corresponding place among [01]~[35/30]
2. Calling Preset Unit Price Mode (01 ~ 35/30)

Weight Unit Price Total


1 0.000 0.00 0.00
Both the scale is empty and there is weight on are ok

2 0.000 1.23 0.00


Press[01]-[35/30] you can call input unit price

Remark: The EEPROM must be 24C04 when using 35/30 PRESET

Preset Using Conditions:


1. Preset function turn on (Note A)
2. The scale should be empty
3. There should not be general tare value (Note B)

(Note A)
Preset function turn on / off (SWA1 should be adjusted to ADJ)
Hold keypad C,it will shows Preset tare state after 2 seconds.
If Preset tare state is on, the Preset tare function will be off and it will restart-up.
If it is on the state of on, it show PT YES; If off, it shows PT NO

(Note B)
If Preset function is on, general tare function can be used (But the premise should be CLEAR
preset tare value), Preset tare function and general tare function can not be used meanwhile.If
you want to use preset tare function, you should clear general tare value to use preset tare
function.

32
EXCELL PRECISION CO., LTD.

Preset tare Operating mode is as follows:


The scale should be empty, and press number key to input the preset tare value you want,
For example, if you want preset tare 1.00kg, you should input 100
It shows as follows:
Weight Unit Price Total
1 0.000 1.00 0.00
The scale should be empty
And there should not be general tare value(Note B)
Press key T , it shows as follows:
Weight Unit Price Total
2 -1.000 preta 0.00
The scale should be empty
And there should not be general tare value(Note B)
If not pressing key F within 2 seconds, you will quit the preset tare value of this time and be
back the last preset tare value. (If the last preset tare value is 0), it shows as follows:
Weight Unit Price Total
0.000 0.00 0.00
The scale should be empty
And there should not be general tare value(Note B)
If pressing key F within 2 seconds, it shows as follows:
Weight Unit Price Total
3 -1.000 0.00 ------
The scale should be empty
And there should not be general tare value(Note B)
At this time,it will occur net and PT light.

To clear preset tare operating mode is as follows:


Press number key 0 to make Unit Price 0, Press key T (The scale should be empty) it shows as
follows:
Weight Unit Price Total
1 -1.000 clean ------
The scale should be empty
And there should not be general tare value(Note B)
If not pressing key F within 2 seconds, you will quit the preset tare value of this time and be
back the last preset tare value.
Weight Unit Price Total
-1.000 0.00 ------
The scale should be empty
And there should not be general tare value(Note B)
If pressing key F within 2 seconds,it shows as follows:
Weight Unit Price Total
2 0.000 0.00 0.00
The scale should be empty
And there should not be general tare value(Note B)
At the moment net and PT light will disappear.

33
EXCELL PRECISION CO., LTD.

Germany best 16KEY 50PRESET settings are as follows: (EEPROM should be 24C04). Preset
PLU setting mode.
1. Hold PLUkey until it shows as follows: (Unit Price shows 0 and flickers )
Weight Unit Price Total
P nr. 0
Both the scale is empty and there is weight on are ok
2. Press number keys to input PLU Address you need (01~50),totally it can record 50 groups.
Weight Unit Price Total
P nr. 1
Both the scale is empty and there is weight on are ok
For example, if you want to store the 1st PLU, press number key 1, when the number key 1
rightmost flickers.
(if you want to store the 32rd PLU, press number key 32, when the number key 2 rightmost
flickers.)
When flickering, you can modify the value input by pressing key C.After 2 seconds,it stops
flickering when it shows Unit Price, entering into inputting PLU,.Total shows 0.00, the
number key 1 rightmost flickers as follows.
3. Entering into inputting PLU, it shows Unit Price, which can be set 5 digits at most.
Weight Unit Price Total
P nr. 32 0.00
Both the scale is empty and there is weight on are ok
If you want to store the unit price of 0.1, press number key 10, then the number rightmost
flickers.
(If you want to store the unit price of 123.45, press number key 12345), then the number
rightmost flickers as follows:
Weight Unit Price Total
P nr. 32 123.45
Both the scale is empty and there is weight on are ok
When flickering, you can modify the value input by pressing key C, After 2 seconds,it stops
flickering (After stoping flickering, you can modify the value input by pressing key C if you want),
At this time, if you want to input the next group of PLU , press PLU key once, then input the next
group of PLU.If finished , press F key.
B. Call PLU Mode
1. Input the PLU number you want.
For example, if you want to call the 32rd PLU, at weighing mode, press number key 32 then
press, PLU key once,you can callo the unit price you need,it shows as follows:
Press number key 32, it shows as follows:
Weight Unit Price Total
0.00 0.32 0.00
Both the scale is empty and there is weight on are ok
Then press PLU key,it shows as follows:
Weight Unit Price Total
0.00 123.45 0.00
Both the scale is empty and there is weight on are ok

34