You are on page 1of 1

NOTES:

A10-D-2209 A10-E-2209 1. FOR GENERAL NOTES, SYMBOLS AND DETAILS SEE DRAWING
A10-A-PID-VA-449162-001 THRU A10-A-PID-VA-449165-003.
CGT APH CIRCULATING WATER HEAD DRUM CGT CONDENSING AIR HEATER 2. BLADDER/DIAPHRAGM TYPE EXPANSION TANK.
3. DELETED.
SIZE (DIA x T-T): 1000.0 mm x 2000.0 mm SIZE(DIA x T-T): 610.0 mm x 1829.0 mm 00A 4. DELETED.
DP: 3.5 barg /FV DUTY: 4698.37 kW 5. 3/8"HOSE AT THE LOW POINT NEAR THE PZV OUTLET FLANGE.
DT: 120 C BARE SURFACE AREA: 46.3 m^2 (EFF) 6. A10-D-1109 NEEDS TO BE HIGHER TNAN ANY POINT OF THE CLOSED
OP: ATM SHELL DP: 12.0 barg /FV CIRCULATION SYSTEM.
A10 OT: 46 C DT: 380 C 7. PUMP SHUT DOWN WHEN TEMPERATURE >55 C .
TI MOC: SA516Gr.70N OP: 4.5 barg 8. ADD MECHANICAL STOP ON TV-1850 AND TV-1851, FLOWRATE SHOULD
2840 INSULATION: HC OT: 155.9/154.88C EQUAL TO PUMP MIN FLOW REQUIREMENT.
TRIM: 3CC1P1 00A MOC: SA516Gr.70N 00A
INSULATION: HC
TRIM: 3CC1P1
A10
FF TUBE DP: 6.5 barg
TT DT: 120 C
2840 OP: 1.4 barg

PB02-LPS-001 Low pressure steam system


OT: 34.9/80C
MOC: SA213 TP316L
RTD INSULATION: HC
A10
TRIM: 1CC1P1 00A
TE
2840
HOLDS: 00A

A10-8"-LPS-22031-3CC1P1 151. ALL CONTROL VALVE SIZE HOLD, WAITING VENDOR INFORMATION.
6767 A10-718578-203
HC (392 C) 100 mm
LP/AUX STEAM FROM
LP/AUX HEADER TO SAFE LOCATION A10 FF
TT
A10-2"-SC-22010-1CC1P1 2851
HC (45 C) 40 mm 00A
A10
RTD
TE
00A
2851
BY SIEMENS
00A 2" V
A10-6"-SC-22014-1CC1P1 12" x 6"
A10-2"-MPC-22015-3CC1P1 2" A10-DOC-151315 LEGEND
7352 A10-718584-205 A HC (85 C) 40 mm
HC (45 C) 40 mm NNF 2" TP CONDENSATE TO CGT PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
CONDENSATE FROM L2B 00A AIR PREHEATER SPECIFICATION SAES-L-105
2" 00A AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT
CONDENSATE PUMP 00A L1B A10-E-1219 AIR FAILURE OPEN VS
00A MBL-052 -VIBRATION SWITCH
A10-G-2001 A10 A10 FF A10
PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
TO SAFE TO SAFE FAILURE STEADY
LG A10-D-2209 LT LI
INSTRUMENT AO/AFC -AIR TO OPEN/
XL -PILOT LIGHT
(NOT FOR MOTOR)
A10-D-2209 LOCATION LOCATION
2841 NOTE 2 2841 2841 L AIR LINE AIR FAILURE CLOSE XS -LIMIT SWITCH
00A MAG GWR TO SAFE TO SAFE AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
INSTRUMENT

A10-3"-LPS-22040-1CC1P

A10-3"-LPS-22042-1CC1P
FAILURE STEADY
LOCATION LOCATION ELECTRICAL LINE DATA LOGGER POINT
AOV -AIR OPERATED VALVE
F-FLOW P-PRESS.

NI (30 C) 0 mm

NI (30 C) 0 mm
A10-4"-SC-22026-1CC1P

INPUTS
A10-4"-SC-22027-1CC1P
AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
2" 2" DT -DENSITY TRANSMITTER

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
X-MISC. A-ALARM
L1A REDUCER ESD -EMER. SHUTDOWN SYSTEM
L2A LOCAL PANEL
FC - FLOW CONTROLLER
00A 20" SPECTACLE MOUNTED INSTR.
00A 3/4" FV -FLOW CONTROL VALVE

NI (30 C) 0 mm
NOTE 6 M1 00A

NI (30 C) 0 mm
3/4" PSET = 12.00 barg PSET = 12.00 barg PLATE-OPEN FCV -FLOW CONTROL VALVE
A10
A10 BOARD MOUNTED
PZV (SELF-ACTUATED)
PZV SPECTACLE INSTRUMENT
B 3" x 2" 3" x 2" PLATE-CLOSED
FE -FLOW ELEMENT
R/G
2260A 2260B FG -FLOW SIGHT GLASS
STATUS LIGHTS
GATE VALVE FHV -FLOW MANUAL CONT. VALVE XL
00A R=RED, G=GREEN
FHTD -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
3/4" 00A

1-1/2" x 1"
00A 1-1/2" x 1"
GLOBE VALVE FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
D PSET = 6.50 barg PSET = 6.50 barg 1" FM -FLOW METER
1" CHECK VALVE
A10
A10
RO -RESTRICTION ORIFICE MOTOR STATUS
PZV

CSO
4" x 3" PZV 4" x 3" A10-1-1/2"-LPS-22039-3CC1P1 PLUG VALVE FQI -FLOW TOTALIZER INDICATOR
PILOT LIGHT

2225A 2225B HC (350 C) 75 mm BALL VALVE


FR -FLOW RECORDER
ML LOCAL MOUNTED
BY SIEMENS 00A A10-1-1/2"-LPS-22041-3CC1P1 00A
FT -FLOW TRANSMITTER INSTRUMENT
DOUBLE DISC FY -FLOW RELAY

3" x 1-1/2" CSC HC (350 C) 75 mm GATE VALVE HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
MBL-053 3" x 1-1/2" 1" ANGLE VALVE HS -HAND SWITCH LOCAL PANEL
A10-2"-SC-22015-1CC1P1 FF
TP A10-3"-SC-22025-1CC1P1 3/4"
A10 A10
LA -LEVEL ALARM
PT PI

CSC
HC (45 C) 40 mm 00A HC (85 C) 40 mm -LEVEL CONTROL VALVE

FB
LV
00A 00A PRESS.RELIEF VALVE RACK MOUNTED
LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
2858 2858

10" x 8"
A10-6"-SC-22001-1CC1P1 I CSO A10-3"-SC-22024-1CC1P1 (SELF-ACTUATED)
A10-DOC-151315 LG -LEVEL GAUGE GLASS ELECTRICAL
HC (35 C) 40 mm HC (85 C) 40 mm LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
CONDENSATE FROM FB VACUUMRELIEF VALVE -LEVEL INDICATOR
LI

A10-6"-SC-22023-1CC1P1
CGT AIR PREHEATER 1" V LR -LEVEL RECORDER INSTRUMENT
00A RTD 00A AIR SUPPLY REQUIRED
A10-E-2219 A10
M MOTOR OPERATED LS -LEVEL SWITCH
TE 6" 10" 2" VALVE LT -LEVEL TRANSMITTER
H
D A LTD -LEVEL TRANSDUCER

HC (85 C) 40 mm
2841 HIGH LOW
00A 00A ML -MOTOR STATUS LIGHT L
A10-E-2209 P
PISTON OPERATED
MOV -MOTOR OPERATED VALVE
6" A10-E-2209
3" NA -ANNUNCIATOR TWO PEN RECORDER
00A VALVE
A10 FF C 2" B1 PB -PUSHBUTTON
TT PC -PRESSURE CONTROLLER FF
CONTROL VALVE PV -PRESS. CONTROL VALVE FOUNDATION
2841 3/4" SP DR PCV -PRESS. CONTROL VALVE FIELDBUS INSTRUMENT
(SELF ACTUATED)
NOTE 7 2215B A10
P
BALL TYPE PDC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
CONTROL VALVE PDI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
FF TC
A10 A10 A10
WITH POSITIONER PDIC -PRESSURE DIFFERENTIAL
TC PDI PDT (DCS) DISTRIBUTED CONTROL
2851 S INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
2841 2846 2846 SOLENOID VALVE PDIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
INDICATOR SWITCH (DCS) DISTRIBUTED CONTROL
00A PDT -PRESS. DIFF. TRANSMITTER
VALVE NORMALLY SYSTEM, OPERATOR INACCESSIBLE
3/4" CLOSED
PDTD -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
PG -PRESSURE GAGE
3/4" 3/4" 3/4" (DCS) DISTRIBUTED CONTROL
3/4" PI -PRESSURE INDICATOR
A10 A10 FF 00A 00A PIC -PRESS. INDICATOR CONTROLLER
SYSTEM, OPERATOR INACCESSIBLE
IN FIELD
PI PT 3/4" D D D

A10-3"-SC-22004-3CC1P1
D

A10-3"-SC-22005-3CC1P1
PR -PRESSURE RECORDER
NOTE 8 00A NOTE 8
00A 2847 2847 00A PS -PRESSURE SWITCH
DISTRIBUTED CONTROL

AC/AFO
PT -PRESSURE TRANSMITTER
AC/AFO

PX -PRESSURE POINT INTERCONNECTING LOGIC


4" 4"

HC (160 C) 50 mm

HC (160 C) 50 mm
3/4" SP PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
FF A10 FF A10
PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
2215A TV 3/4" TV RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
3/4" SI -SPEED INDICATOR
CONTROLLER, NORMALLY
A10 A10 FF 2850 2851 SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
PDI PDT D D TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC
2843 2843 TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
A10-6"-SC-22011-1CC1P1

00A 3/4" SP 3/4" SP (SELF-ACTUATED) CAN BE NORMALLY


TE -TEMP. ELEMENT DISPLAYED ON CRT
3/4" TSO -TIGHT SHUT OFF
A10-6"-SC-22023-1CC1P1 2216A 2216B TG -THERMOMETER LOCAL DCS OR AUXILIARY
A10

FF FF S.C. - SAMPLE CONN. THS -TEMP. HAND SWITCH


HS A10 A10 A10 A10
DCS LOCATION NORMALLY
HC (35 C) 40 mm

A10 A10 FF HC (85 C) 40 mm PDI PDT PDI PDT S -DRAIN TO TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
PI PT 3/4" 2849D PRESSURE SEWER TR -TEMP. RECORDER
2852 2852 2853 2853 TS -TEMP. SWITCH
(PLC) PROGRAMMABLE LOGIC
A10-6"-SC-22001-1CC1P1

2844 2844 I OWS -OILY WATER SEWER TT


CONTROLLER I/O POINT
-TEMP. TRANSMITTER NORMALLY INACCESSIBLE
3/4" 3/4" D -DRAIN TTD -TEMP. TRANSDUCER BY OPERATOR
00A SEE DETAIL 6 -VENT TW
V -THERMOWELL
HC (35 C) 40 mm

A10 SP SP
PI

A10-6"-SC-22013-1CC1P1
REFERENCE DRAWINGS
2292A 2292B
2849
M LETTER IDENTIFICATION OF LINES AE-036204
FT FT PIPING SYMBOLS AB-036227
00A

HC (35 C) 40 mm
00A 3/4" EQUIPMENT SYMBOLS AB-036305
A10 A10 FF A10 A10 FF INSTRUMENT SYMBOLS AC-036950
6" x 5" 6" x 5" PI PT 3/4" PI PT 3/4" 00A PIPING LAYOUT INDEX
3/4" D 00A 00A 2851 2851 2857 2857
00A PLOT PLAN
A10-6"-SC-22012-1CC1P1

3/4" 3/4" PROCESS FLOW DIAGRAM


00A 3/4" D
HYDROSTATIC TEST DIAGRAM

1CC1P1 3CC1P1

1CC1P1 3CC1P1
D D
A10-G-2205B DRAWING CONTROL FOR J.O.
HC (35 C) 40 mm

A10-G-2205B INSTRUMENT INSTALLATION SCHEDULES


Jazan - \A10\A10\VA-718602-202.pid - 9/28/2015 1:45:51 PM - [JE07]

00A

A10-1"-SC-22019-1CC1P1 00A
NI (35 C) 0 mm

OWS SP

A10-4"-MPC-22009-1CC1P1

A10-4"-MPC-22008-1CC1P1
2255A
A10

HS
A10

2848D PC H REVISION VALIDATION

HC (160 C) 50 mm

HC (160 C) 50 mm
2850 THIS REVISION NO. 00A IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
00A SEE DETAIL 6 REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
10-01525-0004-XXX
A10 A10 FF
PI PT
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
2848 2850 (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
M A10-4"-MPC-22009-1CC1P1 ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
6840 A10-718584-214 ML.DONG B.ANDERS

00A 3/4" 3/4" HC (160 C) 50 mm 09/25/15 09/25/15


CONDENSATE TO
CONDENSATE DRAINS REV.NO. DATE REVISION DESCRIPTION
6" x 5" 6" x 5" FLASH DRUM A10-D-2007 00A 09/25/15 ISSUED FOR CONSTRUCTION
3/4" D
00A JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
3/4" D 00A 10-01525-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
A10-G-2205A
SAUDI ARABIAN OIL COMPANY
A10-G-2205A

A10-G-2205A / B 00A
DRAWING TYPE
CGT AIR PREHEATER CIRCULATION PUMP 00A PIPING & INSTRUMENTATION DIAGRAM PID

CAPACITY: 79.8 m^3/hr BLOCK #2 CGT AIR PREHEATING SYSTEM


HEAD: 25.8 m A10-1"-SC-22020-1CC1P1
S.G.: 0.994 NI (35 C) 0 mm POWER GENERATION UNIT
DRIVER POWER: 00A
MOC:
OWS
JAZAN SAUDI ARABIA
TRIM: 1CC1P1 SP PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
2255B
A10 A VA-718602 202 00A
Saudi Aramco 5994 ENG. (09/03)