12/2/2016 LDSforpipelineUSTisaJPTransnafta|WIG

LeakageDetectionSysteminSerbia

FirsteverLDSinSerbia!

Background
WIGandKrohneOilandGas(KOG)deliveredthefirsteverleakagedetectionsysteminSerbia.Thesystemwas
installed,configuredandcommissionedbetweenOctober2012andApril2013.
PipelineUSTisaJPTransnaftais39kmlonganditislocatedinBanat,northernpartofSerbia.
Thepipelineisfunctionallysplitintothreesegmentsandeachofthemhasitsownpiglauncherandreceiver.

Solution
LeakcalculationisdonebyKROHNEPipePatrolLDSSystem.LDSSystemusesrealtimevaluesofprocess
variablessuchasflow,pressureandtemperaturetomakenecessarycalculations.Besidestheserealtimevalues,
gatheredfromsixlocations,LDSSystemincorporatespipelinespecificationssuchaslength,diameter,elevation,
expectedworkingconditionsaswellasspecificationofcrudeoilitself.

Allthestaticandrealtimedataisusedtomakespecificmathematicalmodel,suitedforthisparticularpipelineand
processconditions.LDSSystemutilizesthedatainalgorithmsandmodelssuchasLineBalanceorExtendedReal
TimeTransientmodel(ERTTM)inordertomaximizesystemreliability,overallaccuracyandresponsetime.
RealtimedatacollectionisdonebyGPRS,WiFiandADSL/ISDNlandlines.Timestampinganddataprocessingis
realizedbycontrollersinthefieldtogetherwithGPSclocksusedforacquisitionofprecisetimeandtime
synchronizationforalllocations.
ProcesseddataiscollectedbystateoftheartservermachinethankstoKepwareOPCServer.Thisserveralso
housesKROHNEPipePatrolLDSSystem.
OperatorstationusesthesameKepwareOPCServertocommunicatewithPipePatrolandtherestoftheLDS
system.SupervisionandcontrolonoperatorstationisperformedbyWonderwareArchestraHMIScada.
Wonderwareapplication,asrequestedbythecustomer,isfullyintegratedintotheexistingWonderware
application.Beingjustapartofalargerapplication,itoffersapossibilitytoimplementandcombinepartsofLDS
ScadaapplicationwithanyandallofitsotherScadaapplications.LDSScadaapplicationisalsodevelopedand
designedinaccordancewithcustomersstandardsandrequestconsideringvisualization,security,anduser
interface.

Equipmentandinstrumentation
EquipmentandinstrumentationforLDSSystemisinstalledonsevenlocations,includingthelocationwiththe
serverandoperatorstation.
FieldequipmentusedinLDSSystem(excludingexistingvalvesandflowmeters):
LD301SMAR,pressuretransmitters(HART)
5335BPRELECTRONICS,temperaturetransmitters
TT30CKROHNE,temperaturetransmitters
TT30RKROHNE,temperaturetransmitters
TRAW80KROHNE,groundtemperaturesensors
UFC030withUFM3030KROHNE,ultrasoundflowmeterswithsensors

Communicationandsystemequipment:
ILC171PhoenixContact,PLCcontrollers

http://www.wig.rs/ldspipelineustisajptransnafta?header=header1 1/2
12/2/2016 LDSforpipelineUSTisaJPTransnafta|WIG

WLAN510PhoenixContact,WiFidevices
PSIMODEMGSM/ETHPhoenixContact,GPRSmodems
EDS208andEDS205HMoxa,Ethernetswitches
LANTIMEM100/GPS/DCMeinberg,GPSclocks
GPSantennaeMeinberg
PROL3SolarFabrics,solarpanels
Variousequipment:UPSpowersupplies,batteries,fieldbarriers,voltagecomparators,isolators,convertersetc.
LanguageUndefined