Valves
Check
PRESSURE RELIEVING
AP01B2YP ........ 2G ............... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 .............. PV7-PV8 SH
AP02B2YP ........ C08-2 .......... Increase Pressure/Increase Current .............. 5.3/1.4 ...... 350/5000 ............ PV9-PV10
AP04G2YP ........ C10-2 .......... Increase Pressure/Increase Current ................ 45/12 ...... 350/5000 .......... PV11-PV12
Shuttle
Valves
AP01B2YR ........ 2G ............... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV13-PV14 LM
Load/Motor
AP02B2YR ........ C08-2 .......... Decrease Pressure/Increase Current ............. 5.3/1.4 ...... 350/5000 .......... PV15-PV16
Controls
AP04G2YR ....... C10-2 .......... Decrease Pressure/Increase Current ............... 95/25 ...... 350/5000 .......... PV17-PV18
FC
Controls
PRESSURE REDUCING
Flow
GP01 30 ........... 54-1 ............ Pressure Reducing Valve ................................ 1.9/.5 ...... 210/3000 .......... PV19-PV20
GTP02 34 ......... C08-3 .......... Pressure Reducing Valve .................................. 19/5 ...... 210/3000 .......... PV21-PV22
PC
GTP04 34 ......... 3X ............... Pressure Reducing Valve .................................. 30/8 ...... 210/3000 .......... PV23-PV24
Pressure
Controls
FLOW CONTROLS, 2-Way
DF122C ............. C12-2 .......... Flow Control, N.C. ........................................... 53/14 ...... 210/3000 .......... PV25-PV26 LE
Elements
Logic
DF161C ............. C16-2 .......... Flow Control, N.C. ......................................... 150/40 ...... 210/3000 .......... PV27-PV28 DC
DF201C ............. C20-2 .......... Flow Control, N.C. ......................................... 325/60 ...... 210/3000 .......... PV29-PV30
Directional
Controls
HP02C .............. 2X ............... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV31-PV32
JP02C ............... C08-3 .......... Flow Control, N.C. ............................................. 23/6 ...... 210/3000 .......... PV33-PV34 MV
HP04C .............. C10-2 .......... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV35-PV36
Manual
Valves
JP04C 21 .......... 3X ............... Flow Control, N.C. .......................................... 36/9.5 ...... 210/3000 .......... PV37-PV38
DFA125C21* .... C12-3L ........ Flow Control, N.C. ........................................ 56.8/15 ...... 210/3000 .......... PV39-PV40
*The DFA125C21 will be available January 1, 2011. SV
Solenoid
HP02P .............. 2X ............... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV41-PV42
Valves
JP02P ............... C08-3 .......... Flow Control, N.O. ............................................. 19/5 ...... 210/3000 .......... PV43-PV44
HP04P .............. C10-2 .......... Flow Control, N.O. ............................................. 30/8 ...... 210/3000 .......... PV45-PV46
PV
JP04P ............... 3X ............... Flow Control, N.O. .......................................... 36/9.5 ...... 210/3000 .......... PV47-PV48
Proportional
DF122N ............ C12-2 .......... Flow Control, N.O. ........................................... 53/14 ...... 210/3000 .......... PV49-PV50
Valves
FLOW CONTROLS, 3-WAY
JP04C 31 .......... 4C ............... Priority Flow Control, N.C. ................................. 30/8 ...... 210/3000 .......... PV51-PV52 CE
Electronics
DFA125C31 ...... C12-4L ........ Priority Flow Control, N.C. ............................ 56.8/15 ...... 210/3000 .......... PV53-PV54
Coils &
BC
DIRECTIONAL CONTROL
Bodies &
GP02 51 ........... C08-4 .......... 4 Way, 3 Pos - Closed Center ......................... 21/5.5 ...... 350/5000 .......... PV55-PV56
Cavities
GP02 53 ........... C08-4 .......... 4 Way, 3 Pos - Float Center ............................ 17/4.5 ...... 350/5000 .......... PV57-PV58
TD
DSP105C1 ........ C10-4 .......... 4 Way, 3 Pos - Closed Center ......................... 32/8.5 ...... 210/3000 .......... PV59-PV61
Technical
DSP105C4 ........ C10-4 .......... 4 Way, 3 Pos - Float Center ............................ 32/8.5 ...... 210/3000 .......... PV59-PV61
Data
section we present common options, technical terms, as well as a brief synopsis of the operation and applications
of the various products offered in this section. The intent of this section is to help you in selecting the best
SH
products for your application.
Shuttle
Valves
LM
COMMON OPTIONS
Load/Motor
As you will see, Parker offers a variety of Proportional Valve products. As such, some of the options mentioned
Controls
below may not be available on all valves. Consult the model coding and dimensions for each valve for specifics.
Here are some of the common options available.
FC
Seals: The majority of the products are available in Overrides: Overrides are standard on many of the
Controls
Nitrile or Fluorocarbon Seals. The Winners Circle Parker proportional valves. The override is generally a
Flow
products feature a standard 4301 Polyurethane push type that is flush with the end of the tube. Consult
PC D-Ring. The D-Ring eliminates the need for backup the individual catalog pages for more details.
rings. You should match the seal compatibility to the
Pressure
Controls
LE
Elements
TECHNICAL TERMS
Logic
Ohms Law: Electrical current is generated as a result small back and forth movement of the valve spool
of the relationship between input voltage and the around its set position. This rapid movement reduces
MV resistance to the flow of electrical current. It is the friction of the valve and leads to faster, more
represented in equation form by I = V/R (or V=IR), accurate response.
Manual
This is an important relationship to remember when PWM Frequency: The frequency of a PWM signal is
SV
dealing with any electrically operated valves. the rate at which the signal is turned on and off.
Proportional valves allow varying control of flow or Parkers analog proportional valves are designed to
Solenoid
pressure, dependant on the current signal provided. work with low frequency responses between 100-400
Valves
As coils heat up, their resistance rises. This means a Hz. The performance curves on our catalog pages
higher voltage must be available to maintain the same were performed with a PWM signal at 200 Hz.
PV amount of pressure or flow. Thus, the application
Proportional
needs to be designed such that the full on position is Hysteresis: Due to various factors, the performance
Valves
about 70% of the initial current draw. On the individual of a proportional valve will show a slightly different
catalog pages a maximum control current is specified performance when the current signal is increasing than
CE to help in applying our proportional valves. it will when the signal is being decreased. This
difference is usually expressed as a percentage of
Electronics
PWM: Pulse Width Modulation (PWM) is the preferred total input change and is referred to as the hysteresis
Coils &
We recommend valve drivers with current control for any movement of the spool. Thus, a 20% deadband
optimum performance. PWM signals also usually means that 20% of the control signal is needed before
TD provide dither for the proportional valve. Dither is a the spool will move.
Technical
Data
Valves
Check
infinite adjustment control and flexibility. Parker Hannifin offers various types of proportional flow control, pressure
reducing, and relief valves.
SH
Shuttle
Valves
Proportional flow control valves provide pseudo pressure compensation and are used on systems requiring
variable electronic control of flow. They allow the operator to vary the control signal to accelerate or decelerate an
LM
actuator. A compensator valve can be added to the circuit for enhanced compensation. Some typical applications
Load/Motor
would include the hoist control for a lift, or the speed control for a winch circuit. Parker offers both normally closed
Controls
and normally open versions of proportional flow controls.
Normally Closed FC
Proportional Flow Control (2) (3)
Controls
Flow
OPERATION - With the solenoid
Port (1)
coil de-energized, the spool is held in Is Not Used
PC
a closed position by the spring force. When the
Pressure
solenoid coil is energized, the amperage of the
Controls
signal moves the spool into an open position.
The spool is held in this position by a balance between spring force and electrical force. As the current increases,
the spools opens further; allowing more flow. As the current decreases, the spool begins closing; allowing less LE
flow. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.
Elements
Logic
Normally Open
Proportional Flow Control Out (2)
DC
Directional
In
Controls
OPERATION - With the solenoid (1)
Manual
Valves
allowing less flow to pass. Once a full electronic signal is given, the spool is held in a closed position; allowing no
flow to pass. As the electronic signal is then reduced, the spool begins to open; allowing flow to pass again. Once
a constant electronic signal is given, the spool is held in that position by a balance between electronic force and SV
spring force. Pseudo compensation is obtained by the pressure drop across the orifices in the spool.
Solenoid
Valves
Normally Closed
Proportional Needle Valve
PV
The proportional needle valves
Proportional
are electronic controlled variable
Valves
needle valves. They are designed
specifically for bleed off or unloading
Outlet
circuits as back pressure will affect performance. (1) CE
Electronics
Coils &
degree that corresponds to sensing spool position. The valve will maintain a fixed amount of opening as long as
Cavities
the electrical current remains constant and will vary proportionally with an increase or decrease in current.
TD
Technical
Data
OPERATION - Flow enters the valve through port 3. With the coil de-energized, flow is bypassed to port 2. When
the coil is energized, the internal orifice is increased allowing pressure compensated flow to the priority port (port
4). The excess flow is bypassed to port 2. As input current is increased, the priority flow increases and the bypass
FC
flow decreases. As the current is decreased, priority flow decreases and bypass flow is increased.
Controls
Flow
Direct Acting,
PC Normally Closed Proportional
Pressure Reducing Valve T (1)
Pressure
Controls
when a fixed regulated pressure is required regardless of the inlet pressure. This valve could be used as a clutch
Logic
control for power shift transmissions and PTO, or as a pilot control for directional control valves.
DC OPERATION - With the solenoid coil de-energized, the spool is held in a closed position by spring force. In this
Directional
mode, the regulated pressure port is open to tank and the pressure inlet is blocked. As current is applied to the
Controls
solenoid coil, the spool will begin to travel to a position where the pressure inlet port is connected to the regulated
pressure port. At this point, reduced pressure becomes a function of the current signal. As long as the current
signal is constant, the reduced pressure at the regulated pressure port will remain fixed regardless of any
MV
changes in inlet flow or inlet pressure. As the current signal increases or decreases, the reduced pressure at the
regulated pressure port will change with respect to the changes in signal. Once the coil is fully energized, the
Manual
Valves
reduced pressure of the regulated pressure port will be at the maximum reduced pressure for that valve.
SV
Solenoid
Valves
PV
Proportional
Valves
CE
Electronics
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
Valves
Check
sure to one leg of a hydraulic circuit. In addition these valves act as a relief valve, relieving any shocks or surges
that occur between its regulating port and the actuator. Parker offers direct acting and pilot operated versions of
this valve. The direct acting valves are faster responding and generally have lower hysteresis, but are limited to SH
smaller reduced pressures (generally below 800 psi depending on the valve.) Pilot operated are generally slower
Shuttle
Valves
on response due to the two stage performance, but can have a reduced pressure as high as 3000 psi.
Direct Acting LM
Load/Motor
Controls
OPERATION - With the solenoid Pressure (2) (3) Tank
coil de-energized, the spool is held
in a closed position by spring force. Reg.
(1) FC
In this mode, the regulated pressure port is open to tank
and the pressure inlet port is blocked. As an electronic
Controls
signal is applied to the solenoid coil, the spool will begin
Flow
to travel to a position where the pressure inlet port is connected to the regulated pressure port. At this point,
reduced pressure becomes a function of the voltage signal. As long as the electronic signal is constant, the PC
reduced pressure at the regulated pressure port will remain fixed regardless of any changes in inlet flow or inlet
Pressure
Controls
pressure. As the electronic signal increases or decreases, the reduced pressure at the regulated port will change
with respect to the change in electronic signal. Once a full signal is given, the reduced pressure of the regulated
pressure port will be at the maximum reduced pressure for that valve. LE
Elements
Pilot Operated
Logic
OPERATION - With the solenoid
coil de-energized, the pilot dart is In (2) (3) Tank DC
Directional
held open by the spring force. This
Controls
Reg.
allows the main spool to close and restricts flow from (1)
going from the inlet (2) port to the regulated port (1).
As the electronic signal is applied to the coil, the pilot dart MV
is moved towards the pilot seat restricting pilot flow. This
restriction raises the effective pressure inside the chamber between the spool and the pilot seat, allowing the
Manual
Valves
spool to travel away from the pilot seat to a position where the pressure at inlet (2) is connected to the regulated
pressure port (1). At this point, reduced pressure becomes a function of the electronic signal. As long as the
SV
electronic signal is constant, the reduced pressure at the regulated pressure port (2) will remain fixed regardless
of any changes in inlet flow or inlet pressure. As the electronic signal increases or decreases, the reduced
Solenoid
Valves
pressure at port (1) will change with respect to the change in the electronic signal.
PV
Proportional
Valves
CE
Electronics
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
closed relief defaults to a maximum pressure setting (i.e. 3000 psi) when there is no current applied.
OPERATION - With the solenoid coil de-energized, the pilot dart is held closed by the spring. As current is applied
FC
to the coil, the pilot dart is moved creating less restriction of the pilot flow. As this restriction is reduced with the
increasing current, the pressure setting also decreases. Once a constant electronic signal is given, the pilot dart is
Controls
held in a given position, holding the pressure setting. This is maintained by the balance between the electronic
Flow
Normally Open
Controls
for piloting a larger logic element or vented relief valve. The normally open relief defaults to minimum system
pressure (i.e. 150 psi) when there is no current applied. Normally closed versions are also available upon request.
MV OPERATION - With the solenoid coil de-energized, the pilot dart is held open by the spring. This allows the main
spool to open at minimum pressure 10.4 Bar (150 psi). As current is applied to the coil, the pilot dart is moved
Manual
Valves
towards the pilot seat restricting pilot flow. This restriction raises the effective pressure setting of the valve. Once
a constant electronic signal is given, the pilot dart is held in a given position, holding the pressure setting. This is
SV maintained by a balance between electronic spring force and inlet pressure. As the electronic signal is reduced,
the pilot dart is moved away from the pilot seat. This lowers the effective pressure setting of the valve.
Solenoid
Valves
PV
Proportional
Valves
CE
Electronics
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
PV6
Proportional Control Valves
TD
CE
PV
SV
PC
Data Cavities Electronics Valves Valves Valves Controls Elements Controls Controls Controls Valves Valves
SH
BC
DC
CV
LM
MV
Catalog HY15-3502/US Proportional Relief Valve
Technical Information Series AP01B2YP 07C, 14C, 21C, 35C
CV
General Description
Valves
Features
LM Analog Proportional Relief Valve regulates pressure
proportionally to the solenoid current
Load/Motor
Controls
affecting performance.
PC
Pressure
Controls
Specifications
LE Performance Curves
PWM Current Regulator Recommended
Elements
160 11.4
Port 1 @ 75% 14C 140 Bar (2000 PSI)
Input Current 21C 210 Bar (3000 PSI)
120 8.6
35C 350 Bar (5000 PSI) -21
MV
80 5.7
Hysteresis @ 5% -07
-14
Manual
Valves
200 Hz PWM
40 2.0
Flow (Q)
Cartridge Material All parts steel. All operating Pressure vs. Input Signal (Current)
PV parts hardened steel. PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
5000 345
Measured at coil stabilized
Valves
Operating Temp. -40C to +93.3C (Nitrile) temperature and nominal flow -35
Range/Seals (-40F to +200F) 4000 274
-31.7C to +121.1C (Fluorocarbon)
-21
CE (-25F to +250F)
Pressure
3000 205
Electronics
-14
Coils &
0
Cavities
Valves
Check
62.7 SH
(2.47)
19.8
(0.78)
Shuttle
5/8 Hex.
Valves
4.1 Nm
(3 lb. ft.)
Torque
LM
33.8
Load/Motor
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
(1.33)
Controls
39.6
(1.56)
See Super Coil
1/2" I.D.
75.7 Information For FC
(2.98) Terminal Connectors
Controls
3/4 Hex.
Flow
24 Nm (18 lb. ft.)
Torque
17.9
(0.70) (2) 5/8-18 UNF PC
Pressure
Controls
(1)
12.7
(0.50) NOTE: Requires 2G Cavity
LE
Elements
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
AP01B2YP
Manual
Valves
08 Size Style Seals Coil Coil Coil
Proportional Type Voltage Termination
Relief Valve
SV
Code Style (Maximum Code Seals / Kit No. Code Coil Type Code Coil Termination
Relief Pressure)
Solenoid
N Nitrile / Buna-N (Std.) Omit Without Coil Omit Without Coil
Valves
07C 70 Bar (1000 PSI) (SK30129N-1) SP Super Coil - 19 Watts D DIN Plug Face
14C 140 Bar (2000 PSI) V Fluorocarbon / A Amp Jr. Timer*
21C 210 Bar (3000 PSI) (SK30129V-1)
Code Coil Voltage L Dual Lead Wire* PV
E Ethylene Propylene
Proportional
35C 350 Bar (5000 PSI) Omit Without Coil LS Sealed Lead Wire*
Custom pressure setting available.
Valves
D012 12 VDC H Molded Deutsch*
Consult factory.
D024 24 VDC See Super Coil 1/2 I.D.
*DC Only
CE
Electronics
Coils &
LB10
Cavities
Features
Shuttle
Valves
Controls
FC
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
(2)
affecting performance.
Controls
(1) (2)
Flow
(1)
NOTE:
PC This valve will be available January 1, 2011.
Pressure
Controls
Specifications
LE Performance Curves
PWM Current Regulator Recommended
Elements
160 11.4
Port 1 @ 75% 14C 140 Bar (2000 PSI)
Input Current 21C 210 Bar (3000 PSI)
120 8.6
35C 350 Bar (5000 PSI) -21
MV
80 5.7
Hysteresis @ 5% -07
-14
Manual
Valves
200 Hz PWM
40 2.0
Flow (Q)
Cartridge Material All parts steel. All operating Pressure vs. Input Signal (Current)
PV parts hardened steel. PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
5000 345
Measured at coil stabilized
Valves
Operating Temp. -40C to +93.3C (Nitrile) temperature and nominal flow -35
Range/Seals (-40F to +200F) 4000 274
-31.7C to +121.1C (Fluorocarbon)
-21
CE (-25F to +250F)
Pressure
3000 205
Electronics
-14
Coils &
0
Cavities
Valves
Check
SH
62.7
5/8 Hex. (2.47)
Shuttle
4.1 Nm 19.8
Valves
(3 lb. ft.) (0.78)
Torque
LM
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
Load/Motor
39.5 33.8
Controls
(1.56) (1.33)
See Super Coil
85.8 1/2" I.D.
(3.38) Information For
Terminal Connectors
FC
7/8 Hex.
Controls
30 Nm (22 lb. ft.)
Flow
Torque
27.8 (2) 3/4-16 UNF-2A
Thread PC
(1.10)
Pressure
Controls
(1)
12.6
(0.50) LE
Elements
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
NOTE: MV
AP02B2YP This valve will be available
January 1, 2011.
Manual
Valves
08 Size Style Seals Coil Coil Coil Body Port
Proportional Type Voltage Termination Material Size
Relief Valve
SV
Code Style (Maximum Code Seals / Kit No. Code Coil Voltage Code Body Material
Relief Pressure)
Solenoid
Omit D-Ring / (SK08-2) Omit Without Coil Omit Steel
Valves
07C 70 Bar (1000 PSI) N Nitrile / Buna-N (Std.) D012 12 VDC A Aluminum
14C 140 Bar (2000 PSI) (SK08-2N) D024 24 VDC
21C 210 Bar (3000 PSI) V Fluorocarbon / Code Port Size Body Part No. PV
(SK08-2V)
Proportional
35C 350 Bar (5000 PSI) Code Coil Termination Omit Cartridge Only
Custom pressure setting available.
Valves
Omit Without Coil 4T SAE-4 (B08-2-*4T)
Consult factory. Code Coil Type
D DIN Plug Face 6T SAE-6 (B08-2-*6T)
Omit Without Coil 6B 3/8 BSPG (B08-2-*6B)
A Amp Jr. Timer* CE
SP Super Coil - 19 Watts * Add A for aluminum, omit for steel.
L Dual Lead Wire*
Electronics
H Molded Deutsch*
See Super Coil 1/2 I.D.
*DC Only BC
Bodies &
Cavities
TD
Technical
Data
Features
Shuttle
Valves
input
Controls
Specifications (1)
Relief Performance
PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Factory Set Relief 10C 103 Bar (1500 PSI)
DC 5000 345
Pressure When 21C 210 Bar (3000 PSI)
Directional
-35
Coil De-Energized 35C 350 Bar (5000 PSI)
Pressure Drop ( P)
Controls
-10
Valves
1000 68
Response Time At To Unload 10ms Coil De-Energized
75% of Nominal To Load 300 21
SV 0
Voltage Change 10C 45 ms LPM 19 38 57 76 95
(Measured To 90% 21C 60 ms 0
Solenoid
GPM 5 10 15 20 25
of Press. Change) 35C 80 ms Flow (Q)
Valves
Cartridge Material All parts steel. All operating Pressure vs. Input Current
PV parts hardened steel. PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
5000 345
Measured at coil stabilized
Valves
Operating Temp. -40C to +93.3C (Nitrile) temperature and nominal flow -35
Range/Seals (-40F to +200F) 4000 274
-31.7C to +121.1C (Fluorocarbon)
-21
CE (-25F to +250F)
Pressure
3000 205
Electronics
Coils &
0
Cavities
Valves
Check
62.7
(2.47) SH
19.8
5/8 Hex. (0.78)
Shuttle
Valves
4.1 Nm
(3 lb. ft.)
Torque
LM
33.8
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
Load/Motor
(1.33)
Controls
39.6
(1.56)
Controls
Terminal Connectors
Flow
1 Hex.
34 Nm (25 lb. ft.)
Torque PC
31.8 7/8-14 UNF
Pressure
Controls
(1.25)
(2)
(1) LE
15.8
Elements
(0.62)
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
AP04G2YP
Manual
Valves
10 Size Style Seals Coil Coil Coil Body Port
Proportional Type Voltage Termination Material Size
Relief Valve
SV
Code Style (Maximum Code Coil Type Code Coil Termination Code Body Material
Relief Pressure)
Solenoid
Omit Without Coil Omit Without Coil Omit Steel
Valves
10C 104 Bar (1500 PSI) SP Super Coil - 19 Watts D DIN Plug Face A Aluminum
21C 210 Bar (3000 PSI) A Amp Jr. Timer*
35C 350 Bar (5000 PSI) Code Coil Voltage L Dual Lead Wire* Code Port Size Body Part No. PV
Proportional
Custom pressure setting available. Omit Without Coil LS Sealed Lead Wire* Omit Cartridge Only
Consult factory.
Valves
D012 12 VDC H Molded Deutsch* 4P 1/4 NPTF (B10-2-*4P)
Code Seals / Kit. No. D024 24 VDC See Super Coil 1/2 I.D. 6P 3/8 NPTF (B10-2-*6P)
*DC Only 8P 1/2 NPTF (B10-2-*8P)
N Nitrile / Buna-N (Std.) CE
(SK30503N-1) 6T SAE-6 (B10-2-*6T)
Electronics
8T SAE-8 (B10-2-*8T)
V Fluorocarbon / T8T SAE-8 (B10-2-T8T)
Coils &
(SK30503V-1)
6B 3/8 BSPG (B10-2-*6B)
* Add A for aluminum, omit for steel.
Steel body only. BC
Bodies &
Cavities
TD
Technical
Data
Features
LM Analog Proportional Relief Valve regulates pressure
proportionally to the input solenoid current
Load/Motor
Controls
PC
Pressure
Controls
5000 345
Controls
-07A
1000 68
Hysteresis @ < 10%
SV 200 Hz PWM 0
LPM .95 1.89 2.84 3.78
0
Solenoid
Flow (Q)
parts hardened steel.
Pressure vs. Input Current
PV Operating Temp. -40C to +93.3C (Nitrile) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
3000 205
Electronics
2000 137
0
Cavities
Valves
Check
66.5 SH
25.4 Dia (2.62)
(1.00) 22.0
(0.86)
Shuttle
Finger Tight
Valves
Torque
LM
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
50.0 36.0
Load/Motor
(1.97) (1.43)
Controls
84.0 See Super Coil
(3.32) 5/8" I.D.
Information For
Terminal Connectors FC
3/4 Hex.
Controls
15 Nm (11 lb. ft.)
Flow
26.0 Torque
(1.02) (2)
5/8-18 UNF
PC
(1)
Pressure
12.7
Controls
(0.50) NOTE: Requires 2G Cavity
LE
Elements
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
AP01B2YR
Manual
Valves
08 Size Style Seals Coil Coil Coil
Proportional Type Voltage Termination
Relief Valve
SV
Code Style (Maximum Code Seals / Kit. No. Code Coil Type Code Coil Termination
Relief Pressure)
Solenoid
N Nitrile / Buna-N (Std.) Omit Without Coil Omit Without Coil
Valves
07AL 70 Bar (1000 PSI) (SK30129N-1) SP Super Coil - 28 Watts D DIN Plug Face
14AL 140 Bar (2000 PSI) V Fluorocarbon / A Amp Jr. Timer*
21AL 210 Bar (3000 PSI) (SK30129V-1)
Code Coil Voltage L Dual Lead Wire* PV
E Ethylene Propylene
Proportional
35AL 350 Bar (5000 PSI) Omit Without Coil LS Sealed Lead Wire*
Custom pressure setting available.
Valves
D012 12 VDC H Molded Deutsch*
Consult factory.
D024 24 VDC See Super Coil 5/8 I.D.
*DC Only
CE
Electronics
Coils &
LB10
Cavities
Features
LM Analog Proportional Relief Valve regulates pressure
proportionally to the input solenoid current
Load/Motor
Controls
PC (1)
Pressure
Controls
5000 345
Controls
-07A
1000 68
Hysteresis @ < 10%
SV 200 Hz PWM 0
LPM .95 1.89 2.84 3.78
0
Solenoid
Flow (Q)
parts hardened steel.
PV
Pressure vs. Input Current
Operating Temp. -40C to +93.3C (Nitrile) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
3000 205
Electronics
2000 137
0
Cavities
Valves
Check
SH
66.5
25.4 Dia (2.62)
Shuttle
Valves
(1.00) 22.0
Finger Tight (0.86)
Torque
LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
50.0 36.0
(1.97) (1.43)
See Super Coil
93.3 5/8" I.D.
(3.67) Information For
FC
Terminal Connectors
Controls
3/4 Hex.
Flow
15 Nm (11 lb. ft.)
34.2 Torque
(1.35) (2) PC
3/4-16 UNF
Pressure
Controls
(1)
LE
Elements
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
AP02B2YR
Manual
Valves
08 Size Style Seals Coil Coil Coil Body Port
Proportional Type Voltage Termination Material Size
Relief Valve
SV
Code Style (Maximum Code Coil Type Code Coil Termination Code Body Material
Relief Pressure)
Solenoid
Omit Without Coil Omit Without Coil Omit Steel
Valves
07AL 70 Bar (1000 PSI) SP Super Coil - 28 Watts D DIN Plug Face A Aluminum
14AL 140 Bar (2000 PSI) A Amp Jr. Timer*
21AL 210 Bar (3000 PSI) Code Coil Voltage L Dual Lead Wire* Code Port Size Body Part No. PV
Proportional
35AL 350 Bar (5000 PSI) Omit Without Coil LS Sealed Lead Wire* Omit Cartridge Only
Custom pressure setting available.
Valves
D012 12 VDC H Molded Deutsch* 4P 1/4 NPTF (B08-2-*4P)
Consult factory.
D024 24 VDC See Super Coil 5/8 I.D. 6P 3/8 NPTF (B08-2-*6P)
*DC Only 4T SAE-4 (B08-2-*4T)
Code Seals / Kit. No. CE
6T SAE-6 (B08-2-*6T)
N Nitrile / Buna-N (Std.)
Electronics
TD
Technical
Data
Features
LM Pilot operated spool-type design
Load/Motor
mode
One piece cartridge housing ensures internal
concentricity
FC
Coil: Waterproof, hermetically sealed, requires no
Controls
PC
(1)
Pressure
Controls
Specifications
Relief Performance
PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Factory Set Relief 10C 103 Bar (1500 PSI)
DC 5000 345
Pressure When 21C 210 Bar (3000 PSI)
Directional
-35
Coil De-Energized 35C 350 Bar (5000 PSI)
Controls
-10
Valves
1000 68
Response Time At To Unload 45ms Coil Fully Energized
75% of Nominal To Load 25ms 300 21
SV 0
Voltage Change LPM 19 38 57 76 95
(Measured To 90% 0
Solenoid
GPM 5 10 15 20 25
of Press. Change) Flow (Q)
Valves
Cartridge Material All parts steel. All operating Pressure vs. Input Current
PV parts hardened steel. PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
5000 345
Valves
3000 205
Electronics
-21
Coils &
0
Cavities
Valves
Check
62.7 SH
(2.47)
3/4 Hex. 19.8
4.1 Nm (0.78)
Shuttle
Valves
(3 lb. ft.)
Torque
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
LM
39.6 33.8
Load/Motor
(1.56) (1.33)
Controls
89.7 10.0 See Super Coil
(3.53) (0.40) 1/2" I.D.
Information For FC
Terminal Connectors
Controls
1 Hex.
34 Nm (25 lb. ft.)
Flow
Torque
31.8 7/8-14 UNF PC
(1.25)
(2)
Pressure
Controls
(1)
15.8 LE
(0.62)
Elements
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
AP04G2YR
Manual
Valves
10 Size Style Seals Coil Coil Coil Body Port
Proportional Type Voltage Termination Material Size
Relief Valve
SV
Code Style (Maximum Code Coil Type Code Coil Termination Code Body Material
Relief Pressure)
Solenoid
Omit Without Coil Omit Without Coil Omit Steel
Valves
10C 104 Bar (1500 PSI) SP Super Coil - 19 Watts D DIN Plug Face A Aluminum
21C 210 Bar (3000 PSI) A Amp Jr. Timer*
35C 350 Bar (5000 PSI) Code Coil Voltage L Dual Lead Wire* Code Port Size Body Part No. PV
Proportional
Custom pressure setting available. Omit Without Coil LS Sealed Lead Wire* Omit Cartridge Only
Consult factory.
Valves
D012 12 VDC H Molded Deutsch* 4P 1/4 NPTF (B10-2-*4P)
Code Seals / Kit. No. D024 24 VDC See Super Coil 1/2 I.D. 6P 3/8 NPTF (B10-2-*6P)
*DC Only 8P 1/2 NPTF (B10-2-*8P)
N Nitrile / Buna-N (Std.) CE
(SK30503N-1) 6T SAE-6 (B10-2-*6T)
Electronics
8T SAE-8 (B10-2-*8T)
V Fluorocarbon / T8T SAE-8 (B10-2-T8T)
Coils &
(SK30503V-1)
6B 3/8 BSPG (B10-2-*6B)
* Add A for aluminum, omit for steel.
Steel body only. BC
Bodies &
Cavities
TD
Technical
Data
Features
LM Designed for pilot control of directional valves
Load/Motor
Low Hysteresis
Controls
(3) (2)
Reducing
Pressure
PC (1)
Performance Curves
Pressure
Controls
Energized
Pressure Drop
(At 70 PSI P)
Logic
200 13.6
Max. Regulated Standard 1 to 3
De-Eenergized
DC Pressure @ 75% 17 Bar (250 PSI)
100 6.8
Current High Pressure
Directional
0
Max. Input Press. 210 Bar (3000 PSI) LPM .95 1.9 2.9 3.8
At Port 1 0
GPM .25 .50 .75 1.0
MV Flow (Q)
Max. Tank Press. 30 Bar (440 PSI)
Max. Drainage 5 cc/min. When De-Energized Pressure @ Port 1 vs. Input Current
Manual
Valves
Flow In Regulating 200 cc/min. In Regulating Zone PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Zone At 68 Bar (1000 PSI) Input Pressure 400 27.4
With 'SS' Coil @ 120 Hz PWM
SV Hysteresis @ 2% 300 20.5
200 Hz PWM
Pressure
Solenoid
Valves
0
Cartridge Material All parts steel. All operating
Valves
0
(See BC Section for more details) 24V .1 .2 .3 .4 .5 .6 .7 .8
AMP
Data
Valves
Check
9.70 62.7 SH
(0.38) (2.47)
19.8
12.4 Manual (0.78)
Shuttle
Valves
(0.49) Override
Finger
Tight LM
Torque 33.8
Load/Motor
(1.33)
Controls
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
39.6 XXVDC XXW
(1.56) FC
See Super Coil
5.6 1/2" I.D.
Controls
85.5 (0.22) Information For
Flow
(3.36) Terminal Connectors
13/16 Hex.
27 Nm (20 lb. ft.) PC
Torque
Pressure
M18X1.5
Controls
27.8 (3)
(1.09)
(2)
LE
(1)
11.9
Elements
(0.47) NOTE: Requires 54-1 Cavity
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
GP01 30
Manual
Valves
08 Size Style Override Filter Seals Coil Coil Coil
Proportional Option Screen Type Voltage Termination
Valve
SV
Code Style Code Filter Screen Code Coil Type Code Coil Termination
Solenoid
30 Standard (SS Coil) Omit Not Required Omit Without Coil Omit Without Coil
Valves
30 High Pressure F 60 Mesh Screen on SS Super Coil - 14 Watts D DIN Plug Face
(SP Coil) Inlet Port SP Super Coil - 19 Watts A Amp Jr. Timer*
L Dual Lead Wire* PV
Proportional
Code Override Option Code Seals / Kit No. Code Coil Voltage LS Sealed Lead Wire*
Omit If No M.O. N Nitrile / Buna-N (Std.)
Valves
Omit Without Coil H Molded Deutsch*
1 Manual Override (SK30122N-1)
D012 12 VDC See Super Coil 1/2 I.D.
V Fluorocarbon / *DC Only
(SK30122V-1) D024 24 VDC
CE
Electronics
Coils &
LB10
Cavities
Features
LM Minimal Hysteresis
Load/Motor
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
FC (2) Inlet
affecting performance. (3)
Controls
Pressure
(2)
(1) (3)
PC
Tank
(1)
Pressure
Controls
Specifications
Rated Flow 19 LPM (5 GPM)
LE (At 70 PSI P) Performance Curves
PWM Current Regulator Recommended
Elements
Pressure @ 75% 03 19/26 Bar (270/375 PSI) Pressure Drop vs. Flow
Current 05 31/40 Bar (450/580 PSI) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
DC (Using SP Coil) 06 41/51 Bar (600/740 PSI) 200 14.0
09 65/79 Bar (940/1140 PSI)
Directional
150 10.5
3 to 2
Max. Input Press. 210 Bar (3000 PSI)
At Port 3 100 7.0
MV
Max. Drainage 100 cc/min. When De-Energized 2 to 1
Flow In Regulating 750 cc/min. In Regulating Zone 50 3.5
Manual
Valves
GTP0234 06
-31.7C to +121.1C (Fluorocarbon)
Control Pressure
400 27.4
(-25F to +250F)
CE
Fluid Mineral-based or synthetic with
Electronics
300 20.7
Compatibility/ lubricating properties at viscosities
Coils &
GTP0234 03
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
200 13.8
Filtration ISO Code 16/13,
BC SAE Class 4 or better GTP0234 02
100 6.9
Approx. Weight .08 kg (.17 lbs.)
Bodies &
Cavities
0
Cavity C08-3 24V 0.1 0.2 0.3 0.4 0.5 0.6 0.7
(See BC Section for more details) 0
12V 0.2 0.4 0.6 0.8 1.0 1.2 1.4
TD Current Amps
Technical
Data
Valves
Check
13.21 62.7
(0.52) (2.47)
19.8 SH
Manual Override (0.78)
(Infinite Control)
Shuttle
Valves
3/4 Hex.
4.1 Nm 33.8
(3 lb. ft.) (1.33) LM
Load/Motor
Torque
Controls
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6
(1.56)
See Super Coil
5.59 1/2" I.D. FC
(0.22) Information For
Terminal Connectors
Controls
Flow
93.75 7/8 Hex.
(3.69) 27 Nm (20 lb. ft.)
Torque
PC
3/4-16 UNF
Pressure
Controls
40.21 (3)
(1.58)
(2)
LE
Elements
14.2 (1)
Logic
(0.56)
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
GTP0234 1
Manual
Body Port
Valves
08 Size Style Override Filter Seals Coil Coil Coil
Proportional Option Screen Type Voltage Termination Material Size
Valve
SV
Code Style (Maximum Regulated Code Filter Screen Code Coil Voltage Code Body Material
Pressure Range - SP COIL)
Solenoid
1 60 Mesh Screen on Omit Without Coil Omit Steel
Valves
02 12/17 Bar (180/240 PSI) Inlet Port D012 12 VDC A Aluminum
03 19/26 Bar (270/375 PSI) D024 24 VDC
05 31/40 Bar (450/580 PSI) Code Seals / Kit No. Code Port Size Body Part No. PV
Proportional
06 41/51 Bar (600/740 PSI) N Nitrile / Buna-N (Std.) Code Coil Termination Omit Cartridge Only
09 65/79 Bar (940/1140 PSI) (SK30081N-1)
Valves
Omit Without Coil 4P 1/4 NPTF (B08-3-*4P)
18 114/145 Bar (1650/2100 PSI) V Fluorocarbon /
(SK30081V-1) D DIN Plug Face 4T SAE-4 (B08-3-*4T)
A Amp Jr. Timer* 6T SAE-6 (B08-3-*6T)
CE
Code Override Option L Dual Lead Wire* 6B 3/8 BSPG (B08-3-*6B)
Electronics
Code Coil Type
0 Not Required * Add A for aluminum, omit for steel.
LS Sealed Lead Wire*
Coils &
TD
Technical
Data
Features
LM Minimal Hysteresis
Load/Motor
concentricity
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
FC Inlet
(2)
affecting performance. (3)
Controls
Pressure
(2)
(1) (3)
PC
Tank
Pressure
(1)
Controls
GPM 2 4 6 8 10
Valves
1000 69.0
Operating Temp. -40C to +93.3C (Nitrile)
Valves
200 13.8
Approx. Weight .13 kg (.28 lbs.)
GTP04 3402
Cavity 3X 0
TD (See BC Section for more details) 24V 0.13 0.25 0.38 0.50 0.63 0.75 0.88
0
12V 0.25 0.50 0.75 1.00 1.25 1.50 1.75
Technical
Current Amps
Data
Valves
Check
13.21 Manual Override 66.5
(0.52) (Infinite Control) (2.62)
22.0
(0.86) SH
Shuttle
Valves
3/4 Hex.
4.1 Nm 36.0
(3 lb. ft.) (1.43)
Torque LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
50.0
(1.97)
See Super Coil
5/8" I.D. FC
5.54
(0.22) Information For
Controls
Terminal Connectors
Flow
112.8 1 Hex.
(4.44) 30 Nm (22 lb. ft.)
Torque PC
7/8-14 UNF
Pressure
Controls
(3)
48.87
(1.92)
LE
(2)
Elements
Logic
17.4 (1)
(0.69) NOTE: Requires 3X Cavity THIRD-ANGLE DC
PROJECTION
Directional
Controls
Ordering Information
MV
GTP0434 1
Manual
Valves
10 Size Style Override Filter Seals Coil Coil Coil
Proportional Option Screen Type Voltage Termination
Valve
SV
Code Style (Maximum Regulated Code Override Option Code Seals / Kit No. Code Coil Voltage
Pressure Range - SP Coil)
Solenoid
0 Not Required N Nitrile / Buna-N (Std.) Omit Without Coil
Valves
02 14/17 Bar (200/240 PSI) 5 Detented M.O. (SK30081N-1) D012 12 VDC
03 21/27 Bar (300/390 PSI) V Fluorocarbon / D024 24 VDC
05 29/38 Bar (420/550 PSI) Code Filter Screen (SK30081V-1)
PV
Proportional
09 56/74 Bar (810/1080 PSI) 1 60 Mesh Screen on Code Coil Termination
Contact factory for other regulated Inlet Port Code Coil Type
Valves
Omit Without Coil
pressure to 124 Bar (1800 PSI) Omit Without Coil
D DIN Plug Face
SS Super Coil - 18 Watts
A Amp Jr. Timer* CE
SP Super Coil - 28 Watts
L Dual Lead Wire*
Electronics
H Molded Deutsch*
See Super Coil 5/8 I.D.
Order Bodies Separately *DC Only BC
Bodies &
LB10
Cavities
Features
LM On-off type solenoids
Load/Motor
Low hysteresis
Controls
In
Flow
(1) (2)
PC
Out
(1)
Pressure
Controls
Rated Flow 53 LPM (14 GPM) Pressure Drop vs. Flow @ 100% Control Current
Logic
PSI Bar
Valve Fully Open 300 20.7
Hydraulic Oil 150 SSU @ 100F (32 cSt)
Hysteresis 4%
Controls
@ 200 Hz PWM
100 6.9
Cracking 20% - 30% of Input Signal
MV (Dead band)
0
LPM 19 38 57 76
Frequency 100 - 400 Hz (200 Hz Preferred) 0
Manual
Valves
GPM 5 10 15 20
Flow (Q)
Maximum Control 12 VDC 24VDC
Current 2.45A 1.23A Flow vs. Inlet Pressure @ 100% Control Current
SV GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
Cartridge Material All parts steel. All operating 30 114
parts hardened steel.
Solenoid
Valves
(-25F to +250F) 10 38
Valves
TD
0
Technical
25 50 75 100
0
Data
Valves
Check
56.0 48.0
(2.20) (1.90) SH
Finger
Tight
Shuttle
Valves
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors LM
Load/Motor
Controls
60.0
161.0 (2.35)
(6.33) 17 FC
(.66)
Controls
1-1/4" Hex.
Flow
29 Nm (21 lb. ft.)
Torque
PC
41.3 (2)
Pressure
Controls
1-1/16 - 12 UNF-2A
(1.63)
Thread
22.2 LE
(1) THIRD-ANGLE
PROJECTION
(.87)
Elements
Logic
DC
Directional
Controls
Ordering Information
DF122C14 MV
Manual
Valves
Closed Proportional Options Voltage Wattage Termination Material Size
Flow Control Valve
Code Override Options Code Coil Voltage Code Coil Termination Code Body Material SV
Omit Push Type with Omit Cartridge without Coil Omit Cartridge without Coil Omit Steel
Solenoid
Extended Rod
Valves
D012 12 VDC D DIN A Aluminum
D024 24 VDC P Dual Spade
Code Seals / Kit. No. W Dual Wire Code Port Size Body Part No.
Omit Nitrile / (SK12-2)
PV
Code Coil Wattage See DS Coil 1 I.D. 12P 3/4 NTPF (B12-2-*12P)
Proportional
V Fluorocarbon / (SK12-2V) Omit Cartridge 8T SAE - 8 (B12-2-*8T)
Valves
without Coil 12T SAE - 12 (B12-2-*12T)
H High Watt * Add A for aluminum, omit for steel.
CE
Electronics
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
LM
Features
Load/Motor
Controls
Inlet
Flow
(1) (2)
PC
Outlet
(1)
Pressure
Controls
Rated Flow High Watt Coil Pressure Drop vs. Flow @ 100% Current
Logic
Valve Fully Open 150 LPM (40 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
400 27.6
Maximum Inlet 210 Bar (3000 PSI)
DC Pressure
Directional
300 20.7
Pressure Drop ( P)
(Dead band)
100 6.9
Frequency 100 - 400 Hz (200 Hz Preferred)
SV
Maximum Control 12 VDC 24VDC
Current High Watt 2.45A 1.23A 0
Solenoid
0
Cartridge Material All parts steel. All operating GPM 10 20 30 40
parts hardened steel. Flow (Q)
PV
Operating Temp. -40C to +93.3C (Nitrile)
Proportional
30 113
Viscosity of 45 to 2000 SSU (6 to 420 cSt) High Watt @
Coils &
207 Bar
Flow (Q)
Cavity C16-2 10 38
(See BC Section for more details) High Watt @
34.5 Bar
TD Form Tool Rougher None (500 PSI)
Finisher NFT16-2F 0
A 0 .5 1.0 1.5 2.0 2.5 3.0
Technical
Data
Current in Amps
Valves
Check
56.0 48.1 SH
(2.20) 4.1 Nm (1.90)
(3 lb. ft.)
Torque
Shuttle
Valves
See DS Coil 1" I.D.
Information For
Terminal Connectors LM
Load/Motor
59.8
Controls
(2.35)
136.8 FC
(5.38)
1-1/2" Hex.
Controls
54 Nm (40 lb. ft.)
Flow
Torque
PC
44.4
Pressure
1-5/16 - 12 UN-2A
Controls
(1.75) Thread Inlet
(2)
THIRD-ANGLE
LE
28.5 Outlet PROJECTION
(1)
Elements
(1.12)
Logic
DC
Directional
Controls
Ordering Information
DF161C40 MV
Manual
Valves
Closed Proportional Voltage Termination Material Size
Flow Control Valve
SV
Code Seals / Kit. No. Code Coil Voltage Code Coil Termination Code Body Material
Solenoid
Valves
Omit Nitrile / (SK16-2) Omit Cartridge without Coil Omit Cartridge without Coil Omit Steel
V Fluorocarbon / (SK16-2V) D012 12 VDC D DIN A Aluminum
D024 24 VDC P Dual Spade
PV
W Dual Wire Code Port Size Body Part No.
Proportional
See DS Coil 1 I.D 12P 3/4 NTPF (B16-2-*12P)
Valves
16P 1 NTPF (B16-2-*16P)
8T SAE - 8 (B16-2-*8T)
12T SAE - 12 (B16-2-*12T) CE
16T SAE - 16 (B16-2-*16T)
Electronics
TD
Technical
Data
Features
LM
On-off type solenoids
Load/Motor
Low hysteresis
Controls
Inlet
Controls
(2)
Flow
(2)
Outlet
PC (1)
Pressure
Controls
Rated Flow Low Watt 180 LPM (48 GPM) Pressure Drop vs. Flow @ 100% Current
Logic
Valve Fully Open High Watt 227 LPM (60 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
500 36.2
Maximum Inlet 210 Bar (3000 PSI)
DC Pressure
Directional
400 29.0
Leakage at 125 cc/min. (7.6 in3/min.)
Controls
Pressure Drop ( P)
300 21.7
Hysteresis 4%
MV @ 200 Hz PWM
Cracking 20% - 30% of Input Signal 200 14.5
Manual
Valves
40 150
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Flow (Q)
Low Watt @
34.5 Bar (500 PSI)
Cavity C20-2 10 38
(See BC Section for more details) High Watt @
TD 34.5 Bar (500 PSI)
Form Tool Rougher None 0
A 0 .5 1.0 1.5 2.0 2.5 3.0
Technical
Finisher NFT20-2F
Data
Current in Amps
Valves
Check
56.0 48.3
(2.20)
4.1 Nm
(1.90)
SH
(3 lb. ft.)
Torque
Shuttle
Valves
See DS Coil 1" I.D.
Information For
Terminal Connectors
LM
Load/Motor
60.5
Controls
(2.38)
1-7/8" Hex.
142.2 113 Nm (83 lb. ft.) FC
(5.60) Torque
Controls
Flow
PC
55.1
1 5/8-12 UN-2A
Pressure
(2.17)
Controls
Thread Inlet
(2)
LE
36.8 Outlet
Elements
(1.45) (1)
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
DF201C60 MV
Manual
Valves
Closed Proportional Voltage Wattage Termination Material Size
Flow Control Valve
SV
Code Seals / Kit. No. Code Coil Voltage Code Coil Termination Code Body Material
Solenoid
Valves
Omit Nitrile / (SK20-2) Omit Cartridge without Coil Omit Cartridge without Coil Omit Steel
V Fluorocarbon / (SK20-2V) D012 12 VDC D DIN A Aluminum
D024 24 VDC P Dual Spade
PV
W Dual Wire Code Port Size Body Part No.
Proportional
Code Coil Wattage See DS Coil 1 I.D. 20T SAE - 20 (B20-2-*20T)
Valves
Omit Cartridge 20B 1-1/4 BSPG (B20-2-*20B)
without Coil * Add A for aluminum, omit for steel.
L Low Watt CE
Electronics
H High Watt
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
Features
Shuttle
Valves
FC (1)
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without (1)
Controls
affecting performance.
Flow
LE Performance Curves
Specifications
PWM Current Regulator Recommended
Elements
100 Hz PWM
2 to 1 ('SS' Coil)
Compensator GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
8 30.4
Valves
Cavity 2X
(See BC Section for more details)
Data
Valves
Check
13.21 62.7
(0.52) (2.47)
SH
19.8
Manual Override (0.78)
Shuttle
Valves
(Infinite Control)
3/4 Hex. LM
4.1 Nm 33.8
Load/Motor
(3 lb. ft.) (1.33)
Controls
Torque
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6
(1.56) FC
See Super Coil
5.59 1/2" I.D.
Controls
(0.22) Information For
Terminal Connectors
Flow
82.04 7/8 Hex.
(3.23) 20 Nm (27 lb. ft.) PC
Torque
Pressure
Controls
28.5 3/4-16 UNF
(1.12) (2)
LE
15.9 (1)
Elements
(0.63)
NOTE: Requires 2X Cavity
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
HP02C 21
Manual
Valves
08 Size Style Override Filter Seals Flow Coil Coil Coil
Proportional Option Screen Variation Type Voltage Termination
Valve
SV
Code Style (Maximum Code Filter Screen Code Flow Variation Code Coil Voltage
Regulated Flow)
Solenoid
0 Not Available Omit Standard Up to 20% Omit Without Coil
Valves
21 Standard (SS Coil) of Rated Flow D012 12 VDC
13.3 LPM (3.5 GPM) L Low Variation
Code Seals / Kit No. D024 24 VDC
21 High Flow (SP Coil) (7% of Rated Flow)
22.8 LPM (6.0 GPM) N Nitrile / Buna-N (Std.) PV
Proportional
(SK30076N-1) Code Coil Termination
V Fluorocarbon / Code Coil Type
Valves
Code Override Option Omit Without Coil
(SK30076V-1) Omit Without Coil
0 Not Required D DIN Plug Face
SS Super Coil - 14 Watts
5 Detented M.O. A Amp Jr. Timer* CE
SP Super Coil - 19 Watts
(Infinite Control) L Dual Lead Wire*
Electronics
H Molded Deutsch*
See Super Coil 1/2 I.D.
Order Bodies Separately *DC Only BC
Bodies &
LB10
Cavities
Features
Shuttle
Valves
Port (1)
(3) Is Not Used
PC
Pressure
Controls
('SS' Coil)
Pressure At Port 2
Controls
2 7.6
Minimum Pressure 20 6.9 Bar (150 PSI) Low Flow JP02C 20
('SS' Coil)
Differential 21 13.8 Bar (200 PSI) Standard 0
MV 21 20.7 Bar (300 PSI) High Flow 20 40 60 80 100
0
Maximum Internal 570 cc (35 cu. in.) Input Current (%)
Manual
Valves
6 22.8
JP02C 21 ('SP' Coil)
Valves
4 15.2
@ 35% of Rated Up To 20% Of Rated Flow JP02C 21 ('SS' Coil)
PV Current Model L
2 7.6
Proportional
(-25F to +250F) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Fluid Mineral-based or synthetic with
BC 300 20.7
Compatibility/ lubricating properties at viscosities Measured when valve is fully open
Pressure
200 13.8
Cavities
Cavity C08-3 0
(See BC Section for more details) GPM 1 2 3 4 5 6
Data
Flow
Valves
Check
13.21 62.7
(0.52) (2.47)
19.8
Manual Override (0.78) SH
(Infinite Control)
Shuttle
Valves
3/4 Hex.
4.1 Nm 33.8
(3 lb. ft.) (1.33)
Torque LM
Load/Motor
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
Controls
39.6
(1.56)
See Super Coil
5.54 1/2" I.D.
Information For FC
(0.22)
Terminal Connectors
Controls
96.04 7/8 Hex.
Flow
(3.78) 27 Nm (20 lb. ft.)
Torque
PC
3/4-16 UNF
42.5 (3)
Pressure
Controls
(1.67)
(2)
LE
Elements
14.2
Logic
(0.56) THIRD-ANGLE
PROJECTION
DC
Ordering Information
Directional
Controls
JP02C
08 Size Style Override Filter Seals Flow Coil Coil Coil Body Port MV
Proportional Option Screen Variation Type Voltage Termination Material Size
Valve
Manual
Valves
Code Style (Maximum Code Seals / Kit No. Code Coil Voltage Code Body Material
Regulated Flow) N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
20 Low Flow (SS Coil) (SK30105N-1) SV
D012 12 VDC A Aluminum
7.5 LPM (2 GPM) V Fluorocarbon /
Solenoid
D024 24 VDC
Valves
21 Standard (SS Coil) (SK30105V-1)
15 LPM (4 GPM) Code Port Size Body Part No.
21 High Flow (SP Coil) Code Coil Termination Omit Cartridge Only
Code Flow Variation
23 LPM (6 GPM) Omit Without Coil 4P 1/4 NPTF (B08-3-*4P) PV
Omit Standard Up to 20%
Proportional
of Rated Flow D DIN Plug Face 4T SAE-4 (B08-3-*4T)
6T SAE-6 (B08-3-*6T)
Valves
Code Override Option L Low Variation A Amp Jr. Timer*
0 Not Required (7% of Rated Flow) L Dual Lead Wire* 6B 3/8 BSPG (B08-3-*6B)
* Add A for aluminum, omit for steel.
5 Detented M.O. LS Sealed Lead Wire* CE
(Infinite Control) Code Coil Type H Molded Deutsch*
Electronics
TD
Technical
Data
Features
Shuttle
Valves
(2)
affecting performance.
Flow
PC
Nonmagnetic spool and housing assembly (2)
LE Performance Curves
Specifications PWM Current Regulator Recommended
Elements
Logic
12 45.6
Preferable Input Port 1
'SP' Coil
Port For Best
Flow
MV Hysteresis 8 30.4
Hysteresis @ <10% 'SS' Coil
Manual
100 Hz PWM
Valves
4 15.2
Cracking Pressure 21% of Rated Current (Standard)
SV 17% of Rated Current (High Flow)
0
Variation of Flow Standard Model 20 40 60 80 100
Solenoid
0
@ 35% of Rated Up To 5% Of Rated Flow
Valves
Compensator GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
16 60.8
Valves
Cartridge Material All parts steel. All operating Measured 75% of rated
parts hardened steel. current with 'SP' Coil
Cavity C10-2
(See BC Section for more details)
Data
Valves
Check
13.72 4.0 Manual Override 66.5
Stroke (2.62)
(0.54) (0.16) (Infinite Control) 22.0 SH
(0.86)
7.88
Shuttle
Valves
(0.31)
3/4 Hex.
4.1 Nm 36.0 LM
(3 lb. ft.) (1.43)
Load/Motor
Torque
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
50.0 XXVDC XXW
(1.97) FC
See Super Coil
5/8" I.D.
Controls
5.60 Information For
(0.22)
Flow
Terminal Connectors
96.5 1 Hex.
(3.80) 30 Nm (22 lb. ft.) PC
Torque
Pressure
Controls
33.3 7/8-14 UNF
(1.31) (2)
LE
Elements
15.8 (1)
Logic
(0.62)
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
HP04C 21
Manual
Valves
10 Size Style Override Filter Seals Opening Coil Coil Coil Body Port
Proportional Option Screen Point Type Voltage Termination Material Size
Valve Variation
SV
Code Style (Maximum Code Seals / Kit No. Code Coil Voltage Code Body Material
Regulated Flow)
Solenoid
N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
Valves
21 Standard (SS Coil) (SK30503N-1) D012 12 VDC A Aluminum
30 LPM (8 GPM) V Fluorocarbon / D024 24 VDC
21 High Flow (SP Coil) (SK30503V-1)
36 LPM (9.5 GPM) Code Port Size Body Part No. PV
Proportional
Code Coil Termination Omit Cartridge Only
Code Flow Variation
Valves
Code Override Option Omit Without Coil 4P 1/4 NPTF (B10-2-*4P)
Omit Standard Up to 5% 6P 3/8 NPTF (B10-2-*6P)
0 Not Required of Current D DIN Plug Face
8P 1/2 NPTF (B10-2-*8P)
5 Detented M.O. L Low Variation A Amp Jr. Timer* CE
6T SAE-6 (B10-2-*6T)
(Infinite Control) (2% of Current Flow) L Dual Lead Wire*
Electronics
8T SAE-8 (B10-2-*8T)
LS Sealed Lead Wire* T8T SAE-8 (B10-2-T8T)
Coils &
Code Filter Screen Code Coil Type H Molded Deutsch* 6B 3/8 BSPG (B10-2-*6B)
0 Not Available Omit Without Coil See Super Coil 5/8 I.D. * Add A for aluminum, omit for steel.
*DC Only Steel body only. BC
SS Super Coil - 18 Watts
SP Super Coil - 28 Watts
Bodies &
Cavities
TD
Technical
Data
Features
LM One piece cartridge housing ensures internal
concentricity
Load/Motor
Controls
Performance Curves
LE
PWM Current Regulator Recommended
Specifications Flow vs. Input Signal
Elements
12 45.4
JP04C 21 ("SP" Coil)
Valves
0
parts hardened steel. Bar 35 70 105 140 175 210
0
PSI 500 1000 1500 2000 2500 3000
CE Operating Temp. -40C to +93.3C (Nitrile) Pressure
Range/Seals (-40F to +200F)
Electronics
(-25F to +250F)
PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Fluid Mineral-based or synthetic with
BC Compatibility/ lubricating properties at viscosities 300 20.7
Measured when valve is fully open
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Pressure
200 13.8
Cavities
0
(See BC Section for more details) GPM 2 4 6 8 10 12
Data
Flow
Valves
Check
13.21 Manual Override 66.5
(0.52) (Infinite Control) (2.62)
22.0
(0.86)
SH
Shuttle
Valves
3/4 Hex.
4.1 Nm 36.0
(3 lb. ft.) (1.43)
Torque LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
50.0
(1.97)
See Super Coil
5/8" I.D. FC
5.51 Information For
(0.22) Terminal Connectors
Controls
Flow
115.7 1 Hex.
(4.55) 30 Nm (22 lb. ft.)
Torque PC
7/8-14 UNF
Pressure
Controls
(3)
51.79
(2.04)
LE
(2)
Elements
Logic
17.4 THIRD-ANGLE
Directional
Controls
Ordering Information
JP04C 21 MV
Manual
Valves
Proportional Option Screen Variation Type Voltage Termination
Valve
Code Style (Maximum Code Filter Screen Code Flow Variation Code Coil Voltage SV
Regulated Flow) 0 Not Required Omit Standard Up to 20% Omit Without Coil
Solenoid
21 Standard (SS Coil) of Rated Flow D012 12 VDC
Valves
1 60 Mesh Screen on
30 LPM (8 GPM) Port 2 L Low Variation D024 24 VDC
21 High Flow (SP Coil) (7% of Rated Flow)
36 LPM 9.5 GPM) PV
Code Seals / Kit No. Code Coil Termination
Proportional
N Nitrile / Buna-N (Std.) Code Coil Type
Code Override Option Omit Without Coil
Valves
(SK30106N-1) Omit Without Coil
0 Not Required D DIN Plug Face
V Fluorocarbon / SS Super Coil - 18 Watts
5 Detented M.O. (SK30106V-1) A Amp Jr. Timer*
SP Super Coil - 28 Watts CE
(Infinite Control) L Dual Lead Wire*
Electronics
H Molded Deutsch*
See Super Coil 5/8 I.D.
*DC Only
Order Bodies Separately BC
Bodies &
LB10
Cavities
Features
LM One piece cartridge housing ensures internal
concentricity
Load/Motor
Controls
NOTE:
Flow
Performance Curves
Pressure
Controls
12 45.6
Maximum Input 210 Bar (3000 PSI)
Flow
6 22.8
Controls
12 45.6
Flow
9 34.2
Operating Temp. -40C to +93.3C (Nitrile)
PV Range/Seals (-40F to +200F) 6 22.8
Proportional
25 50 75
0
Fluid Mineral-based or synthetic with Input Current (%)
CE Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Electronics
100 6.9
Cavity C12-3L
(See BC Section for more details)
TD 0
LPM 15.2 30.4 45.5 60.8
0
Technical
GPM 4 8 12 16
Flow (Q)
Data
Valves
Check
15.7 (0.62)
66.5
8.7 2.5 (2.62)
(0.34) (0.10) Manual Override 22.0
(Infinite Control) (0.86) SH
Shuttle
Valves
Finger Tight to
4.1 Nm (3 lb. ft.) 36.0
Max. (1.43)
LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
50.0
XXVDC XXW
(1.97) See Super Coil
5/8" I.D.
99.5 Information For FC
(3.92) Terminal Connectors
Controls
Flow
175.8
(6.92) 4.8 1-1/4" Hex.
(0.19) 74 Nm (55 lb. ft.) PC
Torque
Pressure
19.1
Controls
(0.75)
1-1/16-12UN-2A
Thread
(3) LE
76.2
Elements
(3.00)
Logic
(2)
DC
Directional
Controls
22.2 (1) THIRD-ANGLE
PROJECTION
(0.87)
MV
Ordering Information
Manual
Valves
NOTE:
DFA125C 21 S This valve will be available
SV
12 Size Style Override Seals Coil Coil Coil January 1, 2011.
Solenoid
Proportional Option Type Voltage Termination
Valves
Valve
Code Style (Maximum Code Seals / Kit No. Code Coil Type Code Coil Termination
Regulated Flow) N Nitrile / Buna-N (Std.) Omit Without Coil Omit Without Coil PV
Proportional
21 High Flow (SP Coil) (SK12-3LN) SP Super Coil - 28 Watts D DIN Plug Face
56.8 LPM (15 GPM) V Fluorocarbon /
Valves
A Amp Jr. Timer*
(SK12-3LV)
Code Coil Voltage S Dual Spade*
Code Override Option
Omit Without Coil L Dual Lead Wire*
Omit Not Available CE
D012 12 VDC LS Sealed Lead Wire*
Electronics
S Standard M.O.
D024 24 VDC H Molded Deutsch*
Coils &
(Infinite Control)
See Super Coil 5/8 I.D.
*DC Only
Order Bodies Separately BC
Bodies &
B12 3L A 12T
Cavities
Features
Shuttle
Valves
FC
One piece cartridge housing ensures internal
concentricity (1)
affecting performance.
(2)
PC Nonmagnetic spool and housing assembly
Factory-adjusted low variation option (Model L) is
Pressure
MV 100 Hz PWM 2 to 1 OR 1 to 2
2 7.6
Valves
Cartridge Material All parts steel. All operating Input Current (%)
parts hardened steel.
PV Flow Regulation (Measured at De-Energized Coil)
Operating Temp. -40C to +93.3C (Nitrile)
Proportional
4 15.2
Filtration ISO Code 16/13,
SAE Class 4 or better
BC 2 7.6
Approx. Weight .08 kg (.17 lbs.)
Bodies &
Cavities
Cavity 2X
(See BC Section for more details) 0
Bar 35 70 105 140 175 210
0
TD PSI 500 1000 1500 2000 2500 3000
Pressure
Technical
Data
Valves
Check
13.21 62.7 SH
(0.52) (2.47)
19.8
Manual Override (0.78)
Shuttle
Valves
(Infinite Control)
3/4 Hex. LM
4.1 Nm 33.8
Load/Motor
(3 lb. ft.) (1.33)
Controls
Torque
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6
(1.56) See Super Coil FC
1/2" I.D.
5.59 Information For
Controls
(0.22) Terminal Connectors
Flow
82.04 7/8 Hex.
(3.23) 27 Nm (20 lb. ft.) PC
Torque
Pressure
Controls
28.5 3/4-16 UNF
(1.12) (2)
LE
15.9 (1)
Elements
(0.63) NOTE: Requires 2X Cavity
Logic
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
HP02P 21
Manual
Valves
08 Size Style Override Filter Seals Flow Coil Coil Coil
Proportional Option Screen Variation Type Voltage Termination
Valve
SV
Code Style (Maximum Code Filter Screen Code Flow Variation Code Coil Voltage
Regulated Flow)
Solenoid
0 Not Available Omit Standard Up to 20% Omit Without Coil
Valves
21 High Flow (SP Coil) of Rated Flow D012 12 VDC
19 LPM (5 GPM) L Low Variation
Code Seals / Kit No. D024 24 VDC
(7% of Rated Flow)
N Nitrile / Buna-N (Std.) PV
Code Override Option
Proportional
(SK30076N-1) Code Coil Termination
0 Not Required V Fluorocarbon / Code Coil Type
Valves
Omit Without Coil
5 Detented M.O. (SK30076V-1) Omit Without Coil
(Infinite Control) D DIN Plug Face
SP Super Coil - 19 Watts
A Amp Jr. Timer* CE
L Dual Lead Wire*
Electronics
H Molded Deutsch*
See Super Coil 1/2 I.D.
Order Bodies Separately *DC Only BC
Bodies &
LB10
Cavities
Features
LM One piece cartridge housing ensures internal
concentricity
Load/Motor
Controls
available for applications where low variation of flow from Port (1)
valve to valve is essential at a given current. (3) Is Not Used
PC
Pressure
Controls
Performance Curves
LE
PWM Current Regulator Recommended
Specifications Flow vs. Input Current
Elements
JP02P 21
Directional
2 7.6
Pressure At Port 2 JP02P 20
6 22.8
JP02P 21
Valves
4 15.2
7% Of Rated Flow JP02P 20
PV
Cartridge Material All parts steel. All operating 2 7.6
Proportional
0
Operating Temp. -40C to +93.3C (Nitrile) Bar 35 70 105 140 175 210
0
Range/Seals (-40F to +200F) PSI 500 1000 1500 2000 2500 3000
CE -31.7C to +121.1C (Fluorocarbon) Pressure
(-25F to +250F)
Electronics
de-energized coil
Bodies &
JP02P 21
Approx. Weight .08 kg (.17 lbs.) JP02P 20
100 6.9
TD Cavity C08-3
(See BC Section for more details) 0
LPM 3.8 7.5 11.4 15.2 18.9 22.8
Technical
0
GPM 1 2 3 4 5 6
Data
Flow
Valves
Check
13.21 62.7
(0.52) (2.47)
19.8 SH
Manual Override (0.78)
(Infinite Control)
Shuttle
Valves
3/4 Hex.
4.1 Nm 33.8
(3 lb. ft.) (1.33) LM
Load/Motor
Torque
Controls
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6
(1.56)
See Super Coil
5.54 1/2" I.D. FC
(0.22) Information For
Terminal Connectors
Controls
Flow
96.04 7/8 Hex.
(3.78) 27 Nm (20 lb. ft.)
Torque
PC
3/4-16 UNF
Pressure
(3)
Controls
42.5
(1.67)
(2)
LE
Elements
14.2
Logic
(0.56)
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
JP02P MV
08 Size Style Override Filter Seals Flow Coil Coil Coil Body Port
Material Size
Manual
Proportional Option Screen Variation Type Voltage Termination
Valves
Valve
Code Style (Maximum Code Seals / Kit No. Code Coil Voltage Code Body Material
Regulated Flow) SV
N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
20 Standard (SS Coil) (SK30105N-1)
Solenoid
D012 12 VDC A Aluminum
Valves
9.5 LPM (2.5 GPM) V Fluorocarbon / D024 24 VDC
21 High Flow (SP Coil) (SK30105V-1)
19 LPM (5 GPM) Code Port Size Body Part No.
Code Coil Termination Omit Cartridge Only PV
Code Flow Variation
Proportional
Code Override Option Omit Without Coil 4P 1/4 NPTF (B08-3-*4P)
Omit Standard Up to 20%
Valves
0 Not Required of Rated Flow D DIN Plug Face 4T SAE-4 (B08-3-*4T)
A Amp Jr. Timer* 6T SAE-6 (B08-3-*6T)
5 Detented M.O. L Low Variation
(Infinite Control) (7% of Rated Flow) L Dual Lead Wire* 6B 3/8 BSPG (B08-3-*6B)
* Add A for aluminum, omit for steel.
CE
LS Sealed Lead Wire*
Electronics
0 Not Required Omit Without Coil See Super Coil 1/2 I.D.
*DC Only
1 60 Mesh Screen on SS Super Coil - 14 Watts
Port 2 SP Super Coil - 19 Watts BC
Bodies &
Cavities
TD
Technical
Data
Features
Shuttle
Valves
(2)
ORings; Symmetrical coil can be reversed without
Flow
Specifications
Logic
Hysteresis @ <10%
8 30.4
100 Hz PWM
Flow
MV
Closing Point 65% of Rated Current
4 15.2
Manual
Valves
Cartridge Material All parts steel. All operating Input Current (%)
parts hardened steel.
PV Flow Regulation
Operating Temp. -40C to +93.3C (Nitrile)
Proportional
Valves
Check
13.21 Manual Override 66.5
(0.52) (Infinite Control) (2.62) SH
22.0
(0.86)
8.38
Shuttle
Valves
(0.33)
3/4 Hex.
4.1 Nm 36.0 LM
(3 lb. ft.) (1.43)
Load/Motor
Torque
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
50.0 XXVDC XXW
(1.97) FC
See Super Coil
5/8" I.D.
Controls
Information For
Terminal Connectors
Flow
97.3 1 Hex.
(3.83) 30 Nm (22 lb. ft.) PC
5.59 Torque
Pressure
Controls
(0.22)
7/8-14 UNF
(2)
LE
Elements
15.8 (1)
Logic
(0.62)
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
MV
HP04P 21
Manual
Valves
10 Size Style Override Filter Seals Opening Coil Coil Coil Body Port
Proportional Option Screen Point Type Voltage Termination Material Size
Valve Variation
SV
Code Style (Maximum Code Seals / Kit No. Code Coil Voltage Code Body Material
Regulated Flow)
Solenoid
N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
Valves
21 High Flow (SP Coil) (SK30503N-1) D012 12 VDC A Aluminum
30 LPM (8 GPM) V Fluorocarbon / D024 24 VDC
(SK30503V-1)
Code Port Size Body Part No. PV
Code Override Option
Proportional
Code Coil Termination Omit Cartridge Only
0 Not Required Code Flow Variation
Valves
Omit Without Coil 4P 1/4 NPTF (B10-2-*4P)
5 Detented M.O. Omit Standard Up to 5% 6P 3/8 NPTF (B10-2-*6P)
(Infinite Control) of Current Flow D DIN Plug Face
8P 1/2 NPTF (B10-2-*8P)
L Low Variation A Amp Jr. Timer* CE
6T SAE-6 (B10-2-*6T)
(2% of Current Flow) L Dual Lead Wire*
Electronics
Code Filter Screen 8T SAE-8 (B10-2-*8T)
LS Sealed Lead Wire* T8T SAE-8 (B10-2-T8T)
Coils &
0 Not Available
Code Coil Type H Molded Deutsch* 6B 3/8 BSPG (B10-2-*6B)
Omit Without Coil See Super Coil 5/8 I.D. * Add A for aluminum, omit for steel.
*DC Only Steel body only. BC
SP Super Coil - 28 Watts
Bodies &
Cavities
TD
Technical
Data
Features
LM One piece cartridge housing ensures internal
concentricity
Load/Motor
Controls
Performance Curves
LE
PWM Current Regulator Recommended
Specifications Flow vs. Input Current
Elements
Pressure At Port 2
Directional
Controls
100 Hz PWM
Flow Regulation
Variation of Flow Standard Model GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
SV @ 35% of Rated Up To 20% Of Rated Flow
Current Model L
Solenoid
9 34.2
Valves
7% Of Rated Flow
Flow
0
-31.7C to +121.1C (Fluorocarbon) Bar 35 70 105 140 175 210
0
(-25F to +250F) PSI 500 1000 1500 2000 2500 3000
CE Pressure
Fluid Mineral-based or synthetic with
Electronics
de-energized coil
Approx. Weight .13 kg (.28 lbs.)
Bodies &
200 13.8
Cavities
Cavity 3X
(See BC Section for more details) 100 6.9
TD
0
LPM 7.6 15.2 22.7 30.4 37.8 45.0
Technical
0
GPM 2 4 6 8 10 12
Data
Flow
Valves
Check
13.21 Manual Override 66.5
(0.52) (Infinite Control) (2.62)
22.0
(0.86)
SH
Shuttle
Valves
3/4 Hex.
4.1 Nm 36.0
(3 lb. ft.) (1.43)
Torque LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
50.0
(1.97)
See Super Coil
5/8" I.D. FC
5.51 Information For
(0.22) Terminal Connectors
Controls
Flow
115.7 1 Hex.
(4.55) 30 Nm (22 lb. ft.)
Torque PC
7/8-14 UNF
Pressure
Controls
(3)
51.79
(2.04)
LE
(2)
Elements
Logic
17.4 NOTE: Requires 3X Cavity
THIRD-ANGLE
PROJECTION
(0.68) DC
Directional
Controls
Ordering Information
JP04P 21 MV
Manual
Valves
Proportional Option Screen Variation Type Voltage Termination
Valve
Code Style (Maximum Code Filter Screen Code Flow Variation Code Coil Voltage SV
Regulated Flow) 0 Not Required Omit Standard Up to 20% Omit Without Coil
Solenoid
21 High Flow (SP Coil) of Rated Flow D012 12 VDC
Valves
1 60 Mesh Screen on
36 LPM 9.5 GPM) Port 2 L Low Variation D024 24 VDC
(7% of Rated Flow)
Code Override Option Code Seals / Kit No.
PV
Code Coil Termination
Proportional
0 Not Required N Nitrile / Buna-N (Std.) Code Coil Type
Omit Without Coil
Valves
5 Detented M.O. (SK30106N-1) Omit Without Coil
(Infinite Control) D DIN Plug Face
V Fluorocarbon / SP Super Coil - 28 Watts
(SK30106V-1) A Amp Jr. Timer*
L Dual Lead Wire* CE
Electronics
H Molded Deutsch*
See Super Coil 5/8 I.D.
*DC Only
Order Bodies Separately BC
Bodies &
LB10
Cavities
Features
LM On-off type solenoids
Load/Motor
Low hysteresis
Controls
(1) Out
(2)
PC
In
Pressure
(1)
Controls
Rated Flow 53 LPM (14 GPM) Pressure Drop vs. Flow @ No Current
PSI Bar Hydraulic Oil 150 SSU @ 100 F (32 cSt)
Logic
Hysteresis 4%
Controls
Flow (Q)
Cartridge Material All parts steel. All operating
parts hardened steel. Flow vs. Inlet Pressure @ No Current
GPM LPM
SV 30 114
Hydraulic Oil 150 SSU @ 100 F (32 cSt)
Operating Temp. -40C to +93.3C (Nitrile)
Range/Seals (-40F to +200F)
Solenoid
Valves
(-25F to +250F)
PV Fluid Mineral-based or synthetic with
10 38
Proportional
0
Filtration ISO Code 16/13, Bar 69 138 207
0
SAE Class 4 or better PSI 1000 2000 3000
CE Inlet Pressure
Approx. Weight .32 kg (0.7 lbs.)
Electronics
GPM LPM
Cavity C12-2 15 57
Hydraulic Oil 150 SSU @ 100 F (32 cSt)
(See BC Section for more details)
BC Form Tool Rougher None
10 38
Finisher NFT12-2F
Flow (Q)
Bodies &
Cavities
TD
0
25 50 75 100
Technical
0
Percent of Maximum Control Current
Data
Valves
Check
56.0 48.0
(2.20) (1.90) SH
Finger
Tight
Shuttle
Valves
Torque
See DS Coil 1" I.D.
Information For
Terminal Connectors LM
Load/Motor
Controls
60.0
161.0 (2.35)
(6.33) 17 FC
(.66)
Controls
1-1/4" Hex.
Flow
29 Nm (21 lb. ft.)
Torque
PC
41.3 (2)
Pressure
Controls
1-1/16 - 12 UNF-2A
(1.63)
Thread
22.2 THIRD-ANGLE
LE
(1) PROJECTION
(.87)
Elements
Logic
DC
Directional
Controls
Ordering Information
DF122N14 MV
Manual
Valves
Open Proportional Options Voltage Wattage Termination Material Size
Flow Control Valve
SV
Code Override Options Code Coil Voltage Code Coil Termination Code Body Material
Solenoid
Valves
Omit Push Type with Omit Cartridge without Coil Omit Cartridge without Coil Omit Steel
Extenden Rod D012 12 VDC D DIN A Aluminum
D024 24 VDC P Dual Spade
Code Seals / Kit. No.
PV
W Dual Wire Code Port Size Body Part No.
Proportional
Omit Nitrile / (SK12-2) Code Coil Wattage See DS Coil 1 I.D. 12P 3/4 NTPF (B12-2-*12P)
Valves
V Fluorocarbon / (SK12-2V) Omit Cartridge 8T SAE - 8 (B12-2-*8T)
without Coil 12T SAE - 12 (B12-2-*12T)
H High Watt * Add A for aluminum, omit for steel. CE
Electronics
Coils &
BC
Bodies &
Cavities
TD
Technical
Data
Features
Shuttle
Valves
(4)
concentricity
(3)
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
Inlet
(3)
FC Bypass *
affecting performance. (1)
(2)
Controls
Performance Curves
Specifications PWM Current Regulator Recommended
LE Pressure Compensation of Regulated Flow (Port 4)
Rated Inlet Flow 60 LPM (16 GPM) GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
Elements
Hysteresis @ 7% Pressure
100 Hz PWM
SV Regulated Flow vs. Input Current Stabilized
Opening Point Standard
GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
21% of Nominal Amperage 10 38.0
Solenoid
High Flow
Valves
Model L
20% Of Amperage 2 7.6
Valves
-31.7C to +121.1C (Fluorocarbon) Pressure Drop vs. Flow at Coil Fully Energized
(-25F to +250F) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
300 20.7
BC Fluid Mineral-based or synthetic with
Compatibility/ lubricating properties at viscosities
Pressure
200 13.9
Bodies &
Cavity 4C 0
GPM 2 4 6 8 10 12
(See BC Section for more details)
Data
Flow
Valves
Check
13.21 Manual Override 66.5
(0.52) (Infinite Control) (2.62)
22.0
(Screw Adjust) (0.86)
8.38 SH
(0.33)
3/4 Hex.
Shuttle
Valves
4.1 Nm 36.0
(3 lb. ft.) (1.43)
Torque
LM
Load/Motor
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
50.0
XXVDC XXW
(1.97) See Super Coil
Controls
5/8" I.D.
Information For
Terminal Connectors
FC
1 Hex.
133.4 30 Nm (22 lb. ft.)
Controls
5.59 Torque
(5.25) (0.22)
Flow
Reg. (4) 7/8-14 UNF
PC
In (3)
Pressure
Controls
Byp. (2)
LE
Elements
15.9 (1)
Logic
(0.62)
Ext. Pilot
NOTE: Requires 4C Cavity
THIRD-ANGLE
PROJECTION
DC
Directional
Controls
Ordering Information
JP04C 31 MV
10 Size Style Override Filter Seals Flow Coil Coil Coil
Manual
Proportional Option Screen Variation Type Voltage Termination
Valves
Valve
Code Style (Maximum Code Filter Screen Code Flow Variation Code Coil Voltage
Regulated Flow) SV
0 Not Available Omit Standard Up to 50% Omit Without Coil
31 Standard (SS Coil) of Opening Amps
Solenoid
D012 12 VDC
Valves
26 LPM (7 GPM) L Low Variation (20%
Code Seals / Kit No. D024 24 VDC
31 High Flow (SP Coil) of Opening Amps)
30 LPM (8 GPM) N Nitrile / Buna-N (Std.)
(SK30082N-1) Code Coil Termination PV
Code Coil Type
Proportional
V Fluorocarbon / Omit Without Coil
Code Override Option (SK30082V-1) Omit Without Coil
Valves
0 Not Required D DIN Plug Face
SS Super Coil - 18 Watts
5 Screw Adjust A Amp Jr. Timer*
SP Super Coil - 28 Watts
L Dual Lead Wire* CE
LS Sealed Lead Wire*
Electronics
H Molded Deutsch*
Coils &
LB10
Cavities
Features
Shuttle
Valves
concentricity Reg.
(3)
Coil: Waterproof, hermetically sealed, requires no
ORings; Symmetrical coil can be reversed without
(4)
FC Inlet
affecting performance. (1) (3)
Bypass
Controls
* *
(2)
Flow
(4) (2)
*Always connect Port (1) to
PC Port (4) through .039" orifice. Not Used
(1)
Pressure
Performance Curves
Controls
15 57.0
Rated Regulated 56.8 LPM (15 GPM)
Flow Requires (SP Coil) 12 45.6
DC
Flow
9 34.2
Maximum Input 210 Bar (3000 PSI)
Directional
Controls
3 11.4
Minimum Pressure 13.8 Bar (200 PSI) By-Pass Load Higher Regulated Load Higher
Than Regulated Than By-Pass
MV Differential 0
Bar 210 140 70 0 70 140 210
PSI 3000 2000 1000 0 1000 2000 3000
Maximum Internal 568 cc (35 cu. in.)
Manual
Valves
Pressure
Leakage @ 210 Bar (3000 PSI)
Regulated Flow vs. Input Current Stabilized
SV Hysteresis @ >15% GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
20 76.0
100 Hz PWM
Solenoid
15 57.0
Valves
0
-31.7C to +121.1C (Fluorocarbon) 25 50 75
(-25F to +250F) 0
CE Input Current (%)
Electronics
Viscosity of 45 to 2000 SSU (6 to 420 cSt) PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
300 20.7
TD Cavity C12-4L 0
(See BC Section for more details) LPM 15.2 30.4 45.5 60.8
Technical
0
GPM 4 8 12 16
Data
Flow (Q)
Valves
Check
15.7 (0.62)
66.5
8.7 2.5 (2.62)
(0.34) (0.10) Manual Override 22.0
(Infinite Control) (0.86) SH
Shuttle
Valves
Finger Tight to
4.1 Nm (3 lb. ft.) 36.0
Max. (1.43)
LM
Load/Motor
Controls
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
50.0
XXVDC XXW
(1.97) See Super Coil
5/8" I.D.
99.5 Information For FC
(3.92) Terminal Connectors
Controls
Flow
4.8 1-1/4" Hex.
(0.19) 74 Nm (55 lb. ft.) PC
Torque
Pressure
19.1
Controls
200.3
(7.88) (0.75)
1-1/16-12UN-2A
Thread
LE
Reg. (4)
Elements
Logic
100.6
(3.96) In (3)
DC
Directional
Controls
Byp. (2)
MV
(1)
Manual
Valves
THIRD-ANGLE
PROJECTION
Ext. Pilot
SV
Ordering Information
Solenoid
Valves
DFA125C 31 S
12 Size Style Override Seals Coil Coil Coil PV
Proportional
Proportional Option Type Voltage Termination
Valve
Valves
Code Style (Maximum Code Coil Type Code Coil Termination
Regulated Flow) Omit Without Coil Omit Without Coil
31 High Flow (SP Coil) CE
SP Super Coil - D DIN Plug Face
Electronics
56.8 LPM (15 GPM) 28 Watts A Amp Jr. Timer*
Coils &
S Dual Spade*
Code Override Option Code Coil Voltage L Dual Lead Wire*
Omit Not Available Omit Without Coil LS Sealed Lead Wire* Order Bodies Separately BC
S Standard M.O. D012 12 VDC
(Infinite Control) H Molded Deutsch*
Bodies &
B12 4L A 12T
Cavities
affecting performance.
Controls
Port 1 (2)
(3) (1)
210 Bar (3000 PSI)
PC
Hysteresis @ <6% (1)
100 Hz PWM
Pressure
Controls
Amps
51L 51L
Cartridge Material All parts steel. All operating 1 3.8
52 52
Filtration ISO Code 16/13,
PV SAE Class 4 or better
2 7.6
Proportional
Cavity C08-4 0
24V .80 .60 .40 .20 0 .20 .40 .60 .80
12V 1.60 1.20 .80 .40 Current .40 .80 1.20 1.60
CE 100% 75% 50% 25% Amps 25% 50% 75% 100%
Typical Performance
Electronics
Flow
Cavities
Pressure
Valves
Check
6.0 62.7
3/4 Hex. (.25) Stroke (2.47)
4.1 Nm M.O. Option 19.8 SH
(3 lb. ft.) (Unlatch and (0.78)
Torque Pull or Push)
Shuttle
Valves
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6 b
27.0
(1.56) (1.08) 33.8
Latching (1.33) LM
Sleeve
Load/Motor
94.0
Controls
(3.71)
39.6 a
See Super Coil
FC
(1.56)
1/2" I.D.
Controls
Information For
Flow
Terminal Connectors
7/8 Hex.
30 Nm (22 lb. ft.) PC
Torque Sample
Application Circuit
Pressure
Controls
3 1
(4) (Closed Center) 2
Elements
(2) 3(P) 1(T)
Logic
1
3
Directional
Controls
Ordering Information
MV
GP02
Manual
Valves
08 Size Style Override Seals Coil Coil Coil Body Port
Proportional Option Type Voltage Termination Material Size
Valve SV
Solenoid
Code Style - Closed Center Code Seals / Kit No. Code Coil Voltage Code Body Material
Valves
(Flow Pressure and N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
Performance) (SK30078N-1) D012 12 VDC A Aluminum
51 Standard V Fluorocarbon / D024 24 VDC PV
51L Low Flow (SK30078V-1)
Proportional
52 High Flow Code Port Size Body Part No.
Valves
Code Coil Termination Omit Cartridge Only
Code Coil Type
Omit Without Coil 4T SAE-4 (B08-4-*4T)
Code Override Option Omit Without Coil
D DIN Plug Face 6T SAE-6 (B08-4-*6T) CE
Omit Not Required SS Super Coil - 14 Watts
A Amp Jr. Timer* 6B 3/8 BSPG (B08-4-*6B)
Electronics
2 Detented M.O.
LS Sealed Lead Wire*
H Molded Deutsch*
See Super Coil 1/2 I.D. BC
*DC Only
Bodies &
Cavities
TD
Technical
Data
affecting performance.
Controls
Specifications
FC (2) (4) (4)
Operating Ports 2, 3 and 4 (3)
Controls
Port 1 (2)
210 Bar (3000 PSI) (3) (1)
PC
Hysteresis @ <6% (1)
100 Hz PWM
Pressure
Controls
Cavity C08-4 0
24V .80 .60 .40 .20 0 .20 .40 .60 .80
12V 1.60 1.20 .80 .40 Current .40 .80 1.20 1.60
100% 75% 50% 25% Amps 25% 50% 75% 100%
CE Typical Performance
Electronics
Flow
Cavities
Pressure
Valves
Check
6.0 62.7
3/4 Hex. (.25) Stroke (2.47)
4.1 Nm M.O. Option 19.8 SH
(3 lb. ft.) (Unlatch and (0.78)
Torque Pull or Push)
Shuttle
Valves
MADEINU.S.A.
PAT.XXXXXXX
CCX XXX H
XXVDC XXW
39.6 b
27.0
(1.56) (1.08) 33.8
Latching (1.33) LM
Sleeve
Load/Motor
94.0
Controls
(3.71)
39.6 a
See Super Coil FC
(1.56)
1/2" I.D.
Controls
Information For
Terminal Connectors
Flow
7/8 Hex.
30 Nm (22 lb. ft.) PC
Torque Sample
Application Circuit
Pressure
Controls
3 1
(4) (Floating Center) 2
Elements
(2) 3(P) 1(T)
Logic
1
3
Directional
Controls
Ordering Information
MV
GP02
Manual
Valves
08 Size Style Override Seals Coil Coil Coil Body Port
Proportional Option Type Voltage Termination Material Size
Valve SV
Solenoid
Code Style - Floating Center Code Seals / Kit No. Code Coil Voltage Code Body Material
Valves
(Flow Pressure and N Nitrile / Buna-N (Std.) Omit Without Coil Omit Steel
Performance) (SK30078N-1) D012 12 VDC A Aluminum
53 Standard V Fluorocarbon / D024 24 VDC PV
53L Low Flow (SK30078V-1)
Proportional
54 High Flow Code Port Size Body Part No.
Valves
Code Coil Termination Omit Cartridge Only
Code Coil Type
Omit Without Coil 4T SAE-4 (B08-4-*4T)
Code Override Option Omit Without Coil
D DIN Plug Face 6T SAE-6 (B08-4-*6T) CE
Omit Not Required SS Super Coil - 14 Watts
A Amp Jr. Timer* 6B 3/8 BSPG (B08-4-*6B)
Electronics
2 Detented M.O.
LS Sealed Lead Wire*
H Molded Deutsch*
See Super Coil 1/2 I.D. BC
*DC Only
Bodies &
Cavities
TD
Technical
Data
Features
LM One piece cartridge housing ensures internal
Load/Motor
concentricity
Controls
(4)
(3) (1)
PC (3)
FLOATING CENTER
Pressure
Controls
Specifications
LE (1)
Operating 210 Bar (3000 PSI) (3) (1)
Elements
Pressure
Logic
Hysteresis @ <6%
DC 100 Hz PWM Sample Application Circuit
Directional
Controls
is recommended in
Time at 75% of Off 40 ms Compensator
Valves
Tank Line
(R04H3-15.0)
Amps 2
(-25F to +250F)
Coils &
Compensator
Cavities
Cavity C10-4
Data
Valves
Check
4.8 66.5
3/4 Hex. (.19) Stroke (2.62)
4.1 Nm M.O. Option 22.0 SH
(3 lb. ft.) (Unlatch and (0.86)
Torque Pull or Push)
Shuttle
Valves
50.0 28.0
MADEINU.S.A.
PAT.XXXXXXX
CAX XXX H
XXVDC XXW
(1.97) b (1.10) 36.0
Latching (1.43)
Sleeve LM
Load/Motor
118.0
Controls
(4.66)
50.0 FC
(1.97) a
See Super Coil
Controls
5/8" I.D.
Information For
Flow
Terminal Connectors
1 Hex. PC
34 Nm (25 lb. ft.)
Torque
Pressure
Controls
(4)
63.0
(2.47) (3)
LE
Elements
(2)
Logic
(1)
15.9
(0.63) DC
THIRD-ANGLE
Directional
PROJECTION
Controls
Ordering Information
MV
DSP105
Manual
Valves
10 Size Style Override Seals Coil Coil Coil Body Port
Proportional Option Type Voltage Termination Material Size
Valve SV
Solenoid
Code Style Code Seals / Kit No. Code Coil Voltage Code Body Material
Valves
(2) (4) Omit D-Ring / (SK10-4) Omit Without Coil Omit Steel
C1 N Nitrile / (SK10-4N) D012 12 VDC A Aluminum
V Fluorocarbon / D024 24 VDC PV
Proportional
(3) (1) (SK10-4V) Code Port Size Body Part No.
Omit Cartridge Only
Valves
(2) (4) Code Coil Termination
C4 Code Coil Type Omit Without Coil 6P 3/8 NPTF (B10-4-*6P)
Omit Without Coil D DIN Plug Face 6T SAE-6 (B10-4-*6T)
(3) (1) 8T SAE-8 (B10-4-*8T) CE
SP Super Coil - 28 Watts A Amp Jr. Timer*
Electronics
TD
Technical
Data
51 With 15 Bar, 220 PSI Compensator and SP Coil 53 With 15 Bar, 220 PSI Compensator and SP Coil
GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt) GPM LPM Hydraulic Oil 150 SSU @ 100F (32 cSt)
8 30.4 8 30.4
SH
DSP105C1 DSP105C4
Shuttle
Valves
6 22.8 6 22.8
LM
Load/Motor
Flow
Flow
4 15.2 4 15.2
Controls
FC 2 7.6 2 7.6
Controls
Flow
0 0
-1.8 -1.2 -0.6 0 0.6 1.2 1.8 -1.5 -1.0 -0.5 0 0.5 1.0 1.5
8 30.4
6 22.8
DC
Directional
6 22.8
Controls
Flow
Flow
4 15.2
4 15.2
MV
2 7.6
2 7.6
Manual
Valves
0 0
SV Bar 34 69 103 138 172 207 Bar 34 69 103 138 172 207
0 0
PSI 500 1000 1500 2000 2500 3000 PSI 500 1000 1500 2000 2500 3000
Solenoid
51 Spool Port 3 to 4
PV
PSI Bar Hydraulic Oil 150 SSU @ 100F (32 cSt)
Proportional
300 21
Valves
250 17
Pull
Pressure Drop ( P)
CE Push
200 14
Electronics
Coils &
150 10
BC 100 7
Bodies &
Cavities
50 3
0
TD LPM 8 15 23 30 38
0
Technical
GPM 2 4 6 8 10
Flow (Q)
Data