You are on page 1of 1

100

DO NOT SCALE
65
66

50
67

O
T

C
68

N
VE
69
70
01 02 03 04 05 06 07 08

.3

.2
.2 D
H
.2 D

H
W F
6.
WF

6.
09 10 11 12 13 14 15 16

K
N
SI

50
H.1


25.

FD

P
FW
W. 17 18 19 20 21 22 23 24 25

N
11

FW

P
P

FW
50
Millimetres

FW


26 27 28 29 30 31 32 33 34 35

50
VE P 110

T

1

N
FW NT

VE
T

50
10

N
5


VE
P 0

T
N
110 36 37 38 39 40 41 42 43 44 45

VE
O
46 47 48 49 50 51 52 53 54 55 56 57

C
10
FW 1

0
R
P 0

11
P

TO
1 FW H.2 58 59 60 61 62 63 64


VA
27.

FD
P
FW
10 FW

FW
LA
W.

P
VE P


11
NT 110

0
Y 5
OR 0
AT

0
11
V

O
LA

P
NOTES:

FW
.2
.2 D
110

H
W F

O
5.

K
1. PUBLIC HELTH DRAWING SHALL BE READ WITH THE

C
N
P

50
SI

VE

FW FW

N
T
P
ARCHITECTURAL, STRUCTURAL, ELECTRICAL, A/C & OTHER

FW
P

O
50
.3

C
.2 D
110

H
W F
SS

5.
FW CE SHOP DRAWING BFOR COORDINATION< VERIFICATIONN OF

.4
.2 D

VE YP
T/ A
H
W F
FW P AC

6.

A 50 L)
11
10

VE

(T
N IC
1

50
L

9
P ADEQUATE SPACES & EARLY DETERMINATION OF ANY


AL

.1
.2 D
NT 10

W F
P

H
110

FW

T
W

7.
5

N
.5

4
.2 D

VE
0

.1
.2 D
H
W F
RW CONTRADICTIONS OR INTERFERENCE PER THE PROVISIONS

W F
H
6.
O

7.
wc

C
P

0
11
125 OF THE SPECIFICATION.


.2
.2 D
FWP 50

0
H

.1
.2 D
W F
0

11
FW
5.

W F
H


wc

7.

P
FW
2. FOR EQUIPMENT CAPACITIES, RATING, TYPES &

.6

FW
.2 D
6

H
W F
H.1 wc

6.

P
9
.H.

FD

27.

FD
11
W. wc 27 CHARACTERSTICS REFER TO THE "REPORT"
W.

0
wc
.H .17

FD
VE .27 wc 110 3. PIPE MATERIAL FOR ALL WASTE AND RAIN WATER TO BE
NT W
1 wc P 0

50
W 5 UPVC CLASS 4 RUBBER JOINT.


10 F

FW
NT

T
RW

N
E

VE

8
V P

.1
.2 D

w
11

W F
H
125

7.
4. ALL PIPE DIAMETER SHOWN ARE OUTSIDE DIAMETER

c
w

0
.1
.2 D

.5
.2 D
H
W F
FW

H
W F
7.
FWP 110

7.
P
wc 110 UNLESS NOTED.

1
0

.1
11

.2 D
H
W F

7.
P
FWP 110

0
FW
O

11
5. PIPE MATERIAL WHEN NOT SHOWN ON DRAWINGS SHALL BE

C
FWP 110

H 2

7. E
FWP 110

.2 H
.2
P

W OM
FW
O
2
AS PER CONTRACT SPECIFICATION.

C
.1

T
0
7.H

FW
11

FD
2


W.

P
P

O
IL: +646.50

FW

11

C
VE
0
6. ALL PIPE WORK TO BE LAID GRADIENT 1/100

N
FD

T
.2
FWP 110

W FD

FW
50
7.

3
UNLESS NOTED OTHERWISE.

.1
.2

.2 D
2C

FD

P
H
W F
.H.

7.


FD

50
27

FW
W.

A
.2
FWP 110

.2 D

P
7. RODDING EYE ACCESS POINT SHALL BE PROVIDED

H
W F


7.

FW

11
P

0
FD


AT EVERY CHANGE IN PIPE DIRECTION.

50
FWP 110 8. ALL DIMENSION ARE IN MILLIMETERS AND LEVELS
50 VENT

0
IN METERS UNLESS NOTED OTHERWISE. ALL DIMENSION

.4
11

.2 D
H
W F

O

H.3

7.

C
IL:+645.75

P
.

FD
FW
27 PIPE T/A TO BE VERIFIED ON SITE AND APPROVED BY THE ENGINEER
W.

.3
.2 D

O
H
W F

C
7.
IL:+645.54 9. ALL MATERIALS, EQUIPMENT AND SYSTEMS TO BE
IMPLEMENTED AS PER RELEVANT CONTRACTOR
SPECIFICATION

50

0
11


T
FW

P
VE

FW
P
110
P-TRAP 10. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH
ALL RELEVANT SECTIONS OF THE SPECIFICATIONS.
11. REFER PROJECT WIDE DETAILS FOR LEGEND AND

FW
FD

.6
SYMBOLS AND STANDARD DETAIL.

H
50

7.
FWP 110

.2
W
A SECTION A-A

0
12. TOP OF THE RAIL +646.50 PROPOSED IN DEPOT AREA.

11
_


P
FW

.7
W FD
13. THE TRACK CONSTRUCTION IS BASED ON JTV DRAWING.

H
7.
.2
FWP 110
TOILET DRAINAGE LAYOUT 14. ALIGNMENT INSIDE THE DEPOT AREA IS BASED ON TSY
DRAWING M3-TSY-ZDQ-SYS00-PWD-D20-00050700-AB8
2 ISOMETRIC DIAGRAM

.8
W FD
H
7.
FWP 110

.2
15. THE 0.00 LEVEL IS THE TOR +646.50"
1180049 SCALE N.T.S.

0
11

P
FW
16. FOR PIPES CONNECTION TO ROADWAY MANHOLES REFER
TO CIVIL ROADWAY DRAWING DETAILS.

25 26 27 REFERENCE DRAWING:
PUBLIC HEALTH DWG. REFERENCE
M3-DJV-EDR-EPH00-D70-DEP-1181519-520
REV. AF

10000 10000 AB
IL: +645.52 FWP 110 mm DIA IL: +645.47
RWP 200
MHE2
RWP 250 MHE2 IL: +644.77
IL: +645.54 FWP 110 IL: +645.54
IL: +644.83 IL: +645.17
T/A F/A
FWP 110 CO IL: +645.54
IL: +645.74 IL: +645.74
IL: +645.55 IL: +645.55 IL: +645.55
TRAP PRIMER 15
W.25.H.1 IL: +645.72 IL: +645.70 IL: +645.57 IL: +645.75
FD FD

H' IL: +645.55


FD
W.25.H.2
FD
W.26.H.1 FD
W.26.H.2 IL: +645.74 IL: +645.31
CO
F/A

F/A RWP 125


TRAP PRIMER 15

A
_
F/A

F/A
E
W.27.H.9
RWP 125
IL: +645.56
FWP 110
FWP 110 IL: +645.56 IL: +645.75 FD
IL: +645.57 IL: +645.72 W.26.H.2
MHE1 VEN 110 IL: +645.74
W.27.H.20 F/A
IL: +645.55
F/A T/A IL: +645.49
IL: +645.72 IL: +645.57 IL: +645.84 FD
IL: +645.57 IL: +645.59 CO FWP 50 W.27.H.5 Internal Ref. Internal Rev.
FD
N/A N/A
FD IL: +645.74

L= 2664
IL: +645.56 FWP 110 W.27.H.14
F/A FWP 110 W.25.H.3 W.26.H.3 VEN 50 FWP 50 IL: +645.57

1%
T/A
IL: +645.59 FD
IL: +645.59 IL: +645.58 IL: +645.59 F/A
CO IL: +645.74 FD
F/A FWP 110 W.27.H.10
F/A FWP 50 IL: +645.57
IL: +645.75 FD IL: +645.57
CO IL: +645.75 W.27.H.15
IL: +645.60 IL: +645.60 CO F/A
IL: +645.60 IL: +645.57 IL: +645.56
F/A
IL: +645.75
FD
IL: +645.57 IL: +645.56 W.27.H.11 IL: +645.57
FD
IL: +645.59 IL: +645.58 W.27.H.19 W.27.H.16 FWP 50
FWP 110 F/A FD
F/A F/A
IL: +645.56 FD
F/A
IL: +645.56 FWP 110
FWP 110 IL: +645.57 AB 11:10:16 SECOND SUBMISSION TO RAMPED MJM ALAA ALAA
FWP 110 FD
FWP 50 W.27.H.12
IL: +645.59
F/A
IL: +645.59 FD
W.27.H.17 F/A FWP 50 ENLARGED TOILET DETAIL
AA 20:07:16 FIRST SUBMISSION TO RAMPED MJM ALAA ALAA
IL: +645.57
AA2 25:04:16 SECOND SUBMISSION TO DJV LRO ALAA ALAA
VENT 110
IL: +645.59
T/A IL: +645.59 REFER TO DWG NO. 1181548-3
VEN 110 VENT 110 IL: +645.59 AA1 09:01:16 CREATION LRO ALAA ALAA
CO FD T/A FD
W.27.H.18 CO CO W.27.H.13 Rev. Date Description By Chk'd App'd
VEN 50
L= 585 CO Drawing Status
F/A IL: +645.75
IL: +645.75
2000 L W.27.H.2C
FD
FWP 110
2000 L
F/A
CO
SHOP DRAWING
CLIENT
PRAYER'S ROOM MEN FWP 110
W.27.H.2B
FD IL: +645.59 IL: +645.58

CO W.27.H.6
FWP 110 FD
DF315Bm W.26.H.4
FD
VEN 50 IL: +645.75 IL: +645.59 IL: +645.57 PROJECT CONTRACTOR
IL: +645.75
W.27.H.2A W.27.H.4
FD FD
IL: +645.75 IL: +645.75
IL: +645.60
T/A FWP 110 IL: +645.59 W.27.H.7
FD Project Title
1 REFER TO TYPICAL IL: +645.59
IL: +645.56
1180043 WALL ACCESS DETAIL FD
IL: +645.59 IL: +645.75
LOCKERS AND TOILETS MEN
RIYADH METRO
W.26.H.5 FWP 110 IL: +645.75
IL: +645.60
IL: +645.75
F/A
W.27.H.1 W.27.H.3
DF302m

IL: +645.57 W.27.H.8 FWP 110 Package 3 (Lines 4, 5 & 6)


IL: +645.60 FD FD FD
Drawing Title
IL: +645.55
FWP 110 IL: +645.57 FWP 50 LINES 4&6 DEPOT
H
PRAYER'S ROOM WOMEN
W.26.H.6
DF315Bw FD LOCKERS AND TOILETS WOMEN

DF302w
WASTE & RAIN WATER DRAINAGE NETWORK
IL: +645.56
F/A WORKSHOPS
FWP 110
UNDER SLAB PART 33 & 34 TOILET
FWP 110
Scale Designed Drawn Checked Approved

IL: +645.53 AS SHOWN LARRY/MJM ALAA ALAA


GROUND LEVEL PLAN- PART 33-34 FWP 100 mm DIA
Original Size
A1
Date Date Date Date
IL: +645.56 20:07:16 20:07:16 20:07:16
1 ENLARGED TOILET DRAINAGE LAYOUT Drawing Number Revision
1180018 SCALE 1 : 50
M3- FSA- SDR- EPH00- D70- DEP- 1180048 AB
Copyright C ADA (2015) Filename:
Author:

You might also like