You are on page 1of 103

BABYPLAST 6/10P

Touch screen

INSTRUCTION MANUAL
Rev 2
BABYPLAST 6/10P

INSTRUCTION MANUAL
Thank you for the trust you have placed in CRONOPLAST.
Please read this manual carefully before operating our machinery.
The manufacturer is not responsible for and does not provide
warranty for machines used for any purpose other than that for which the
manufacturer has specified.

The manufacturer reserves the right to modify their product data or


features without prior notice.

WARNING
Before starting up the machine or carrying out any maintenance work,
read this instruction manual carefully

TECHNICAL ASSISTANCE

CRONOPLAST sl

CRONOPLAST S.L. C/Francesc Layret, 12-14 nave 23 - Pol. Ind. Sant Ermengol II - 08630 Abrera ( Barcelona) Espaa
Tel. 93 770 50 78 Fax 93 770 19 54
www.babyplast.com
Last mod. 15/04/2008
BABYPLAST 6/10P

CE CONFORMITY STATEMENT

We hereby declare that the product type refered to is is a:


BABYPLAST MODEL 6/10P, WITH SERIAL NUMBER: .................
MANUFACTURER : CRONOPLAST S.L. -
TO BE USED SOLELY FOR THE INJECTION MOULDING OF THERMOPOLYMERS: EXCLUDING
INFLAMMABLE AND OR EXPLOSIVE POLYMERS.

(according to delivery note nr. .............................dated...........................)

Babyplast 6/10P conforms to the following European standards:

- 98/37/CEE and subsequent modifications


- 89/336/CEE and subsequent modifications (electromagnetic compliance directives)
- 73/23/CEE and subsequent modifications (low voltage directives)

AUTHORISED STANDARDS APPLIED FOR THE CONFORMITY DECLARATION

For machine directives 98/37/CE :


UNI EN 292-1
UNI EN 292-2
UNI EN 201

For electromagnetic compliance directives (89/336/CEE) :


CEI EN 61000-6-2:2001
CEI EN 61000-6-4:2001

For low voltage directives (73/23/CEE) :


CEI EN 60204-1

Conformity to the declared standards carried out by:

- UNI EN 292-1, UNI EN 292-2, UNI EN 201 : Quadra report RTE002


- CEI EN 61000-6-2, CEI EN 61000-6-4 : Eletech report 50261EMC01.00
- CEI EN 60204-1 : Eletech report 50261LVD01.00
BABYPLAST 6/10P

GENERAL INDEX

CONTENTS

A/ General conditions and characteristics of BABYPLAST 6/10P............................... A-0010


B/ How to install a BABYPLAST 6/10P............................................................................. B-0010
C/ Start up ......................................................................................................................... C-0010
D/ How to operate a BABYPLAST 6/10P......................................................................... D-0010
E/ Alarms............................................................................................................................. E-0010
F/ Maintenance & technical drawings.............................................................................. F-0010

A/ General conditions and characteristics of BABYPLAST 6/10P.


A.1/ General conditions......................................................................................................... A-0010
A.2/ What is a BABYPLAST 6/10P and what can it do?...................................................... A-0010
A.3/ Technical data................................................................................................................A-0020
A.3.1/ General dimensions of BABYPLAST 6/10P.................................................. A-0020
A.3.2/ BABYPLAST 6/10P, Basic parts list................................................................ A-0030
A.3.3/ Technical data..................................................................................................A-0040
A.3.4/ General mould dimensions.............................................................................. A-0050
A.3.4a/ Assembly diagramme to show mould installation............................A-0060
A.3.4b/ Drawing to show mould assembly.................................................. A-0070
A.3.5/ Increasing the gap between the machine platens by 25mm........................... A-0080
A.3.6/ How to move the injection point off centre...................................................... A-0090
A.3.7/ Diagramme to show injection pressures......................................................... A-0100
A.4/ Warranty........................................................................................................................ A-0100

B/ How to install a BABYPLAST 6/10P................................................................................B-0010

B.1/ Unpacking and parts check........................................................................................... B-0010


B.2/ Position the machine on a work bench......................................................................... B-0010
B.3/ Electrical connections 400V 3 phase + N + earth....................................................... B-0020
B.4/ Electrical connections 230V 3 phase + earth............................................................... B-0020
B.5/ Cooling system............................................................................................................. B-0030
B.6/ Hydraulic oil specifications............................................................................................. B-0040

C/ Start up.............................................................................................................................C-0010

C.1/ Safety devices................................................................................................................C-0010


C.1.1/ Main switch...................................................................................................... C-0020
C.1.2/ Emergency stop...............................................................................................C-0020
C.1.3/ Hydraulic system safety device....................................................................... C-0030
C.1.4/ Safety devices for guard and transparent gate............................................... C-0040
C.2/ Installing a mould........................................................................................................... C-0050
C.3/ Display panel..................................................................................................................C-0060
C.4/ Pressure gauges................................................................................................... C-0060
C.5/ Cooling system - water manifold..............................................................................C-0070
C.6/ Display - Synoptic diagramme................................................................................C-0080
C.7/ Starting the machine.............................................................................................. C-0090
BABYPLAST 6/10P

D/ How to use a BABYPLAST 6/10P........................................................................D-0010

D.1/ Menu................................................................................................................................... D-0010


D.1.1/ Display....................................................................................................................D-0010
D.1.2/ Icons - description of functions............................................................................. D-0020
D.1.3/ Start up - gate check.............................................................................................. D-0030
D.1.4/ Main menu............................................................................................................. D-0040
D.1.5/ Manual menu......................................................................................................... D-0050
D.1.5a/ Manual menu CLAMP................................................................................ D-0060
D.1.6/Setting the MOULD CLOSED position................................................................... D-0070
D.1.7/Automatic menu...................................................................................................... D-0080
D.1.7a/ Temperature settings................................................................................. D-0090
D.1.7b/ Times and settings.................................................................................... D-0100
D-1.7b1/INJECTION CARRIAGE settings................................................. D-0110
D-1.7b2/ PLASTIFICATION settings...................................................... D-0120
D-1.7b3/ EJECTION settings.................................................................D-0130
D-1.7b4/ INJECTION settings............................................................... D-0140
D-1.7b5/ CLAMP settings.................................................................... D-0150
D-1.7b5.a/CLAMP settings....................................................................D-0155
D-1.7b6/ QUALITY CONTROL settings.................................................. D-0160
D.2/Starting a cycle........................................................................................................ D-0190
D.2.1/ Starting an automatic cycle............................................................................ D-0190
D.2.2/ Starting a semi automatic cycle.......................................................................D-0210
D.2.3/ Starting a purge cycle..................................................................................... D-0230
D.2.4/Setting up the PART COUNTER........................................................................D-0250

D.3/ Mould setting programmes........................................................................................ D-0260


D.3.1/ Loading a mould setting programme.............................................................. D-0260
D.3.2/ Create or modify a mould setting programme.................................................... D-0270
D.3.2a/Mould setting programmes - times and settings.......................................D-0280
D.3.2a.1/ INJECTION CARRIAGE..........................................................D-0280
D.3.2a.2/ LOADING.......................................... .................................. D-0290
D.3.2a.3 / EJECTION........................................................................... D-0300
D.3.2a.4/ INJECTION........................................................................... D-0310
D.3.2a.5/ CLAMP................................................................................ D-0320
D.3.2b/ Mould setting programmes TEMPERATURES............................................... D-0330
D.3.2c/ CORE PULL.................................................................................................D-0340
D.3.3/ Mould setting programmes - COPY A PROGRAMME............................................. D-0350

D.4/Machine configuration.......................................................................................................... D-0370


D.4.1/Machine configuration - Change language - Celsius/Farenheit.............................. D-0380
D.4.2/Machine configuration - Temperatures.................................................................. D-0390
D.4.3/Machine configuration - Times and settings........................................................D-0400
D.4.4/Software Upgrade.............................................................................................D-0405

D.5/ USB memory stick - Saving/retrieving mould settings.................................................. D-0410


D.5.1/Printing/Elaborating mould setting data on a PC................................................... D-0430

E/ ALARMS...................................................................................................................... E-0010
F/ Maintenance..................................................................................................................F-0010
F/2 Electrical and hydraulic drawings...................................................................................F-0020
..............................................................................................F-0140
BABYPLAST 6/10P

GENERAL SAFETY REGULATIONS

To be studied carefully before using the machine

The Babyplast 6/10P injection moulding machine, for thermoplastic materials, has been constructed to
meet most safety regulations actually in force. Failure to respect the following instructions, may cause injury
to the user or damage to the machine.

1) Do not remove the warning labels from the machine. These labels must always be clearly visible.

2) Before using a thermoplastic material, always consult the manufacturer about possible health risks and the
precautions that must be taken in order to avoid accidents.

3) To avoid the risk of electric shock, never use the machine unless it has been properly earthed.

4) All the safety guards on the machine must be positioned correctly and maintained in good working order.

5) The protective covers over the electrical and electronical compartments, must remain closed and screwed
down. The removal of the protective covers, may expose the operator to the risk of electric shock.

6) Safety devices, covers and protections, should not be deactivated or tampered with.

7) When working near the injection area, always wear protective gloves and suitable eye protections.

8) The various components of the mould must be correctly positioned and well secured before starting the
injection phase.

9) Before carrying out any maintenance, the machine must by disconnected from the mains and the main
switch must be turned off and blocked by a qualified technician.

10) The system that limits the hydraulic pressure, must always be regulated so that the pressure does not
exceed the maximum pressure of 130 bar.

11) Never place hands or other objects inside the protective guards while the machine is functioning.

12) Maintenance on the machine should be carried out by qualified personnel only.

13) The machine is supplied with a power supply cable but without a plug. The plug used should comply to
standard EN 60309-1 and 16A power rating.

14) The machine must be connected to the power supply via a mains switch with a rating of
of at least 4500A at 230V / 400V. The power supply socket and switch must be installed in visable position
for easy access and must have an identification sign or label.

IT IS THE RESPONSIBILITY OF THE OWNER TO ENSURE THAT THE MACHINE MEETS MAXIMUM
SAFETY LEVELS AT ALL TIMES, AND THAT THE OPERATOR ALWAYS RESPECTS THE SAFETY AND
MAINTENANCE INSTRUCTIONS FOUND IN THIS MANUAL AND ON THE LABELS ATTACHED TO THE
MACHINE. IN CASE OF DOUBT AND OR FOR ANY FURTHER CLARIFICATIONS, PLEASE CONTACT
YOUR NEAREST DEALER.
BABYPLAST 6/10P A
A.1/ GENERAL CONDITIONS

This technical documentation is intended for all those responsible for using and handling the BABYPLAST 6/10P
injection moulding machine.
We wish to emphasise that this injection moulding machine can only be used according to the instructions set out
in this manual.
Failure to follow this instruction manual correctly, may cause injuries to people and animals or damage to
materials and things.
In the event of any problems, please contact our technical staff.
In its continued endeavour to improve its products, CRONOPLAST reserves the right to vary or modify such
products without prior notice.
It is strictly forbidden to reproduce or copy this manual without written prior consent from CRONOPLAST S.L.,
or to use said manual for unauthorised purposes.

BABYPLAST 6/10P is a PATENTED model.

BABYPLAST 6/10P has been designed and built according to EN 201, EN 60204-1-1992, EN 292-1, EN 292-2.
The above include DIN 5310, DIN 5318T2, DIN 54635T48, according to the 89 / 392 / EEC and
93 / 44 / EEC Directives on machinery.

The machine is certified as complying with the European standard "CE".


ATTENTION! It is forbidden to sell or transfer this machine to the U.S.A., Canada and Mexico, unless the
mechanical safety device kit has been installed. The manufacturer and distributor will not accept
responsibility for accidents caused due to failure to observe this warning.

The technical documentation for the machine, if within the European Economic Community, is provided in the
language of the country of destination. For multi-lingual countries or those outside the European Community, the
required language should be specified in the customers order.

A.2/ WHAT IS A BABYPLAST 6/10P AND WHAT CAN IT DO?

The BABYPLAST 6/10P injection moulding machine is the result of thirty years experience working in specific
fields of plastic injection moulding, mould design and construction.
Research and development, on the machine, began more than ten years ago, in response to an important area
of demand:

-SMALL SERIES PRODUCTION.


-PROTOTYPE DEVELOPMENT.
-LOW COST OF MOULDS..
-LABORATORY TESTS.
-TECHNICAL TRAINING.

BABYPLAST 6/10P is the ideal solution for producing small plastic-moulded parts, without using multiple cavity
moulds. This is particularly useful when developing prototypes or producing small series of parts.
Owing to the low cost of the moulds used in our machines, in-depth experiments can be carried out before the
final mould for large series production is built.
As a result, both small and medium series can be produced easily, and COMPLETELY AUTONOMOUSLY.

Thank you for the trust you have placed in Babyplast. We are confident that your BABYPLAST 6/10P machine,
will help fulfil your application expectations.
When handling and processing any injection moulding materials, customers must follow the material manufacturer's
instructions with great care.

A-0010
A BABYPLAST 6/10P

A.3./ TECHNICAL DATA


A.3.1/ General Dimensions

All dimensions are in mm.

A-0020
BABYPLAST 6/10P A
A.3.2/ Babyplast 6/10P - BASIC PARTS LIST

1-Alarm warning light. 20-Guard - injection


2-Dial for changing data 21-Plastification chamber
3-Display 22-Plastification piston
4-Function keys. 23-Hopper cover
5-Guard - Clamp piston 24-Hopper
6-Clamp piston 25-Injection chamber
7-Transducer - clamp. 26-Nozzle
8-Water connections moving mould half 27-Fixed platen
9-Clamp pressure gauge 28-Moving platen
10-Emergency stop button 29-Transparent gate
11-Injection pressure gauge 30-Access to power supply & Euromap board
12-Hydraulic safety device 31-Plastification heat guard
13-Exit chute for parts 32-Mains power supply cable
14-Water connections fixed mould half 33-Access to fuses, power board & CPU board
15-Water manifold 34-Main switch
16-Water inlet-oulet 35-Drain
17-Aluminium slide rail for guards 36-Inspection cover for hydraulic manifold.
18-Injection carriage assembly
19-Transducer - injection piston

A-0030
A BABYPLAST 6/10P

A.3.3/ TECHNICAL DATA

Piston diameter (mm.): 10 12 14 16 18


Volume (cm3): 4 6, 5 9 12 15
Injection pressure (Kg/cm2.) : 2.650 1.830 1.340 1.030 815
Clamp force : 6.250 Kg. cm3 62.5 KN
Opening force : 400 Kg. 4 KN
Opening stroke : 30 - 110 mm.
Ejection force: 750 Kg. 7.5 KN
Ejection stroke : 45 mm.
Hydraulic pressure : 130 Kg./cm2.
Oil tank capacity : 12 l. (approximately)
Dry cycle : 2.4 s.
Rated power : 3.0 Kw
Weight : ~ 150 Kg.
Noise level : < 70 db
Power supply: 3 ~ 230V. 50/60 Hz. + Earth
3 ~ 400V. 50/60 Hz. +Neutral + Earth

A circuit breaker must be used at the mains connection.

A-0040
BABYPLAST 6/10P A
A.3.4/ GENERAL MOULD DIMENSIONS

MOULD DIMENSIONS

ATTENTION: When the machine is set up for the 25mm extra opening, the thickness
of the mould must also be increased accordingly from 70mm to 95mm

MAIN DIMENSIONS FOR INSTALLING A MOULD


DISTANCE INSIDE GATE
A = approx. 50mm
B = approx. 60mm
Opening stroke Min. thickness

Ejector stroke
Moving mould half Nozzle travel Fixed mould half

All dimensions are in mm

For further information on mould dimensions,please see the enlarged drawings on the follwing pages.

A-0050
A BABYPLAST 6/10P

A.3.4a/ ASSEMBLY DIAGRAMME TO SHOW MOULD INSTALLATION

2 or 4 screws - DIN 912 M.6 x 80

IMPORTANT - Coupling
pin must be made so that
it cannot rotate
(e.g. square head).

Screw - DIN 912 M.4 x 20


Grub screws - DIN 913 m. 10 X 25

Assemble with M4 allen


key.

2 or 4 screws - DIN 912 M.6 x 35

NOTE: Locating sides A e B must be machined to high precision.


NEVER USE THE MACHINE WITHOUT A MOULD INSTALLED

For instructions on how to install a mould, please see parag. C.2 MOULD INSTALLATION page- C-0050

ATTENTION: When using heated moulds with temperatures exceeding 60 / 70C, insulation plates
must be fitted around the mould and a special cooling ring (part number C10006600)
must be fitted to the moving platen. Failure to do so may cause overheating to the
machine and damage to seals and clamp assembly.

A-0060
BABYPLAST 6/10P A
A.3.4b/ DRAWING TO SHOW MOULD ASSEMBLY

4,5

A-0070
A BABYPLAST 6/10P

A.3.5/ Increasing the gap between the machine platens by 25 mm.

1 2 3 4 5 6 7
max 180 mm

2 max 205 mm
8

1. Column fixing screws. 5. Fixed platen


2. 25mm spacer. 6. column head.
3. Columns. 7. Fixed platen fixing screws.
4. Mobile platen 8. Column fixing block.

TO INCREASE THE GAP BETWEEN THE PLATENS, PROCEED AS FOLLOWS:


Unscrew and remove the fixing screws 1 and the 25 mm spacer 2 .Unscrew, the column head 6 in
order to insert the 25 mm spacer 2 into the block 8 , and the fixing screws 7 in order to move the fixed
platen back 5 by 25 mm. Replace the columns ensuring that they are pushed well into their respective holes
and tighten the 4 screws 1 crosswise.

ATTENTION:
IN CONFIGURATION A THE MINIMUM THICKNESS OF THE MOULD IS 70mm.
IN CONFIGURATION B THE MINIMUM THICKNESS OF THE MOULD IS 95mm.

A-0080
BABYPLAST 6/10P A
A.3.6/ HOW TO MOVE THE INJECTION POINT OFF CENTRE

1. Centre position A. Protection fixing position - injection assembly in central position.


2. 25mm off centre position B. Protection fixing position - injection assembly in off centre position.
3. Silicon protection

The Babyplast 6/10P, has two injection positions, one central and one 25mm off centre.

TO MOVE THE INJECTION ASSEMBLY OFF CENTRE BY 25mm, PROCEED AS FOLLOWS:

Unscrew and remove the fixing screws from position 1. Slide the columns out from position 1 and
insert them into position 2 (25mm lower). Screw in and tighten the two fixing screws in the new
position.

IMPORTANT: Having moved the injection assembly off centre, move the connection point of the
silicon protection from position A to position B

ATTENTION: THE MACHINE MUST BE DISCONNECTED FROM THE POWER


SUPPLY BEFORE CARRYING OUT THIS OPERATION.

A-0090
A BABYPLAST 6/10P

A.3.7/ DIAGRAMME TO SHOW INJECTION PRESSURES

kg/cm2
3.000

2.500
Specific pressure on material

Injection piston
10mm*
2.000
12mm

1.500
14mm
16mm
1.000
18mm

500

0 10 20 30 40 50 60 70 80 90 100 110 120 kg/cm2


Hydraulic pressure
* IMPORTANT NOTE: The maximum hydraulic pressure for the 10mm piston must be limited to 100 bar. This is done automatically by setting
the value of 10mm for the piston size under TIMES AND SETTINGS in the MACHINE PARAMETERS menu see section D.4.3, page D-0400.

A.4/ WARRANTY

The vendor guarantees that the material is to be supplied against all manufacturing faults, and accepts replacing
any faulty part or repairing any faulty operation free-of-charge, providing the buyer notifies the vendor of said fault
within a maximum period of TWELVE MONTHS from the date the machine is received at its destination.

It is clearly stated that this warranty does not include: heating elements, paint, oil and optional accessories; wear
caused through improper use and handling; knocks, in the case of damaged / broken seals on the hydraulic unit,
If the maximum authorised pressure levels have been exceeded, troubles caused by faulty connections in the
electrical system, the use of un-authorised lubricants, accidents and damage or any failure to observe the
application and installation instructions detailed in this manual.
Furthermore. the travelling expenses of a technician (hours and kilometres) as well as transport costs for
replacement parts are also excluded.
Once the TWELVE MONTH warranty period has expired, the vendor will not accept any claims or returned parts.
However, faults that the buyer issues claims for, may be checked by the vendor, using any technical means
considered necessary, on condition that the buyer does not obstruct the work of those who the vendor has
nominated responsible for carrying out the revision.

WARNING:

In its continual endeavour to improve its products, CRONOPLAST reserves the right to modify or vary its products
features or specifications without prior notification.

A-0100
BABYPLAST 6/10P B
B/ HOW TO INSTALL A BABYPLAST 6/10P
B.1/ UNPACKING AND PARTS CHECK

First of all remove the screws in the case as shown in Fig. 1b., and lift the case lid to remove the contents
(Fig. 2b), check that there are no faulty parts. If any of the parts are faulty, notify your nearest distributor
immediately. Dismantle the front and rear fixing bars.
You will find the following parts inside the packing case: (Fig. 3b.)

a/ 1 BABYPLAST 6/10P.
b/ 2 slings for transfering the machine to its work site.
c/ 1 instruction manual.
d/ 1 hopper.
e/ 1 bag containing spare parts and their corresponding list.

B.2/ POSITION THE MACHINE ON A WORK BENCH

There are 4 guides welded underneath the BABYPLAST 6/10P chassis; pass the slings through these guides as
shown in Fig. 4b. and secure them in the crane hook. (Before positioning the slings, open the 2 guards and move
the transparent gate to the left, (cf: Fig. 5b.). Use a crane to lift the machine and place it above the work bench
(the approximate machine weight is 120 kg). During this operation,it is very important to handle the machine
with care. (Fig. 6b). The machine must be installed in a well illuminated, dry place where the surrounding
temperature does not exceed 40C.

B-0010
B BABYPLAST 6/10P

B.3/ ELECTRICAL CONNECTIONS for 400V power supply

3 phase + neutral + earth - 400V - 50/60Hz

The mains power supply fuses inside Babyplast 6/10 have a blow rating of 3.500 A at 400V.
The machine must be connected to the mains via a 16A thermo / 0,030A differential circuit breaker,
that is suitable for the power supply used.

Attention! For power supplies with the neutral isolated from earth, a relay for permanent isolation must
be installed.

B.4/ ELECTRICAL CONNECTIONS for 230V power supply

3 phase +earth - 230v - 50/60Hz

The mains power supply fuses inside BABYPLAST 6/10 have a blow rating of 10.000 A at 230V.
The machine must be connected to the mains via a 16A thermo / 0,030A differential circuit breaker,
that is suitable for the power supply used.

BABYPLAST 6/10 will be prepared for connecting to a power supply as specified in the customers order.

Current: Max 7,5A - average 3,5A

FUSES INSTALLED ON THE fm542 BOARD -

Fuse pos. Technical Dimensions Power rating FUNCTION


number specifications

F501 10A - 500V - rapid blow 6,3X32 F 500V/ 1.500A - 250V/10.000A PHASE R
F502 10A - 500V - rapid blow 6,3X32 F 500V/ 1.500A - 250V/10.000A PHASE S
F503 10A - 500V - rapid blow 6,3X32 F 500V/ 1.500A - 250V/10.000A PHASE T

F504 8A - 250V - rapid blow 6,3X32 F 24V POWER

F505 8A - 500V -extra rapid 6,3X32 FF 500V/ 1.500A - 250V/10.000A Plast. heater
F506 3,15A - 500V - extra rapid 6,3X32 FF 500V/ 1.500A - 250V/10.000A Chamber heater
F507 3,15A - 500V - extra rapid 6,3X32 FF 500V/ 1.500A - 250V/10.000A Nozzle heater
F508 6,3A - 500V - extra rapid 6,3X32 FF 500V/ 1.500A - 250V/10.000A F. mould heater
F509 3,15A - 500V - extra rapid 6,3X32 FF 500V/ 1.500A - 250V/10.000A M. mould heater

B-0020
BABYPLAST 6/10P B
B.5/ COOLING SYSTEM

This is needed to:


Cool the hydraulic oil.
Cool other parts of the machine.

For connecting the cooling water supply to the BABYPLAST 6/10 machine, the inlet and outlet hose must be
of a flexible type. Connect the inlet hose to the water supply (see diagramme), the outlet hose to the return
circiuit and open the shut-off valve.

The temperature of the incoming water must be between 12C (min.) and 18C (max.). However, the
minimum and maximum temperatures are indicative only and depend on the machine settings and working
conditions.
The water must be clean, otherwise a filter must be used and the calcium content controlled.
The water hardness must be between 6 grd-9grd dH, and the pressure between 3-4bar (max.) with a
difference between the inlet and outlet of 1.5 bar.

B-0030
B BABYPLAST 6/10P

B.6/ HYDRAULIC OIL SPECIFICATIONS

BABYPLAST 6/10 is not supplied with hydraulic oil unless requested as an accessory. Only an oil with the
following properties can be used in the machine.

OIL PROPERTIES: RANGE: -15C +80C


VISCOSITY: 12 100 mm /SEC.(CST)
FILTRATION: 25 30 um. MINIMUM

AGIP-OSO45
CASTROL-HISPIN AWS46
CHEVRON-EPHIDRAULIC OIL 11
ESSO -NUTOH48
IP-IPHYDRUS OIL 46
MACH -BP ENERGOL HLP80
MOBIL-DTE MEDIUM
FIAT- RZA 40
TOTAL- AZOLLA 30

VERY IMPORTANT
The guarantee on the machine will be void if any oils other than those listed above are used in the machine.
CRONOPLAST does not accept any responsibility in such cases.

How to fill the machine with hydraulic oil.

Remove the oil cap and fill the tank until the level reaches the mark on the dipstick. attached to the oil cap.
ATTENTION: THERE IS A SENSOR WITH A FLOAT, INSIDE THE OIL TANK, WHICH CAUSES THE
MACHINE TO GO INTO ALARM (ALARM 023) IF THE OIL LEVEL IS TOO LOW.

OPERATING TEMPERATURE: 45C


MAXIMUM TEMPERATURE : 60C (ALARM 020)
MINIMUM TEMPERATURE : 15C (ALARM 029).Below the minimum temperature, it will only be possible
to switch on the motor, heaters and consult the various menus and settings. No machine movements will be
possible.

Oil return filter

Maximum hydraulic
pressure adjustment valve

Oil fill cap

B-0040
BABYPLAST 6/10P C
C./ START UP
C.1/ Safety devices

Position of safety devices.


Safety for the user.
Mould safety.
Safety standards. EN 60204 T1/1985 DIN VDE 0113 T1/02.B6

1. Main Switch 6. Safety device for clamp guard

2. Emergency stop. 7. Safety device for clamp guard

3. Hydraulic system safety device. 8. Safety device for injection guard

4. Safety device for transparent gate. 9 Safety device for injection guard

5 Safety device for transparent gate. 10. Heat guard

C-0010
C BABYPLAST 6/10P

C.1.1/ MAIN SWITCH

The main switch switches the


machine ON and OFF and is found
on the side of the machine (figure
1c).
It has two positions (0 off - 1 on).
When i n position 0 it is possible to
insert a padlock to block it for safety
reasons.

fig. 1c

C.1.2/ EMERGENCY STOP

The emergency stop button switches off the motor, all the electro-valves (thus stopping all the machines
movements) all the heater elements, and activates alarm 031 EMERGENCY STOP.
To restart the machine, once the emergency stop button has been pushed, rotate the button anti-clockwise
and reset the alarm on the display.

P P

C-0020
BABYPLAST 6/10P C
C.1.3/ HYDRAULIC SYSTEM SAFETY DEVICE

When the transparent gate is opened, the power supply to the valves is cut and a safety release valve is
activated which diverts all the hydraulic fluid in the system to the oil tank, thus stopping all the machines
movements. The safety valve (page F-0140 - pos. 21) is fitted with a switch which to monitor and ensure that
it functions correctly.
If the transparent guard is closed and the hydraulic safety device does not return to its working position, alarm
002 GATE OPEN is activated.

Transparent gate

Aluminium rail

Hydraulic safety
device

Inspection hole

If the machine has not been used for a long period or after transport, the plunger on the hydraulic safety
device, situated behind the aluminium rail near the transparent gate (see drawing above), may become stuck.
To free the plunger, open the gate, insert a small screwdriver into the inspection hole and push the plunger in
and out.

C-0030
C BABYPLAST 6/10P

C.1.4/ SAFETY DEVICES FOR GUARDS AND TRANSPARENT GATE

1-2-3/ Safety devices - Transparent gate


When the safety devices for the transparent gate are activated, the power supply to the electrovalves, which
control the machine movements, is cut and the hydraulic safety device is activated to divert all the hydraulic oil
in the system back to the tank. Alarm 002 is activated which in turn activates the alarm warning light and
acoustic alarm.
1 2 3

4-5/ Safety devices - Clamp guard


When the safety devices for the Clamp guard are activated, the power supply to the electrovalves, which
control the machine movements, is cut and the hydraulic safety device is activated to divert all the hydraulic oil
in the system back to the tank. Alarm 001 is activated which in turn activates the alarm warning light and
acoustic alarm.
4 5

6-7/ Safety devices - Injection guard


When the safety devices for the Injection guard are activated, the power supply to the electrovalves, which
control the machine movements, is cut and the hydraulic safety device is activated to divert all the hydraulic oil
in the system back to the tank. Alarm 003 is activated which in turn activates the alarm warning light and
acoustic alarm.

6 7

C-0040
BABYPLAST 6/10P C
C.2/ INSTALLING A MOULD

Ensure that the previous instructions have been followed carefully, that there are no oil or water
leaks and that the electrical connections and power supply are correct.

The mould halves are installed in the cavities in the machine platens as follows:

A./ Place each mould half in the corresponding cavity in each platen and
slightly tighten the DIN 913 M10 x 25 grub screws to hold them in place.
B-/ Fix the ejector coupling pin to the ejector piston using an M4x20 allen
head screw.
C-/ Secure the mould halves to the platens, using 2 or 4 DIN 912 M6 x 80
screws for each mould half, and tighten well. Tighten the four DIN 913
M10 x 25 grub screws which centre the mould halves.
D-/ Each mould half should protrude at least 15mm from their respective
platen in order to install cooling or heating.

( CRONOPLAST S.L. and RAMBALDI Srl are highly experienced in the design, development and construction
of Babyplast moulds and are ready to provide expert service and advice in order to offer their customers
complete turn key solutions).

2 or 4 screws - DIN 912 M.6 x 80

IMPORTANT - Coupling
pin must be made so that
it cannot rotate
(e.g. square head).

Screw - DIN 912 M.4 x 20


Grub screws - DIN 913 m. 10 X 25

Assemble with M4 allen


key.

2 or 4 screws - DIN 912 M.6 x 35

NOTE: Locating sides


A e B must be
machined to
high precision.

C-0050
C BABYPLAST 6/10P

C.3/ DISPLAY PANEL

Tool settings are set and saved via the multi-function touch-screen display. It is also possible to control the various
functions of the machine and handle and activate the various phases of the cycle.
A. TOUCH-SCREEN DISPLAY
Visualise all data and functions of the
machine as well as the synoptic
diagramme of the machine. Allows
machine parameters to be varied or
saved, by touching the various icons
or fields of data. MENU PRINCIPALE

B. References for icons


The following refences are used (F1- 000.0mm

F2 etc..) to simplify the explanations 00.0mm

of the functions of the various icons


referred to in this manual on the touch-
screen display.

C. ALARM WARNING LIGHT


Lights up when an alarm is activated.
At the same time a description of the
alarm/fault appears on the display.

D. DIAL
Allows a more rapid input/change
A B C D
of data.

C.4/ PRESSURE GAUGES

These are situated on the lower left-hand side of the machine.

1 2

P P

1 CLAMP PRESSURE GAUGE


Indicates the CLAMP PRESSURE which corresponds to the maximum working pressure of the machine.
(system pressure 130bar).

2 INJECTION PRESSURE GAUGE


Indicates the INJECTION PRESSURE (1st Pressure - 2nd Pressure)
C-0060
BABYPLAST 6/10P C
C.5/ COOLING SYSTEM - WATER MANIFOLD

Situated on the lower right-hand side of the machine.

Icons : indicate the cooling


zone.

Sphere : Indicates the


25 25 25 actual water flow rate.
20 20 20
15 15 15 Control knobs: adjust the
water flow rate to each
10 10 10
zone
5 5 5
0 0 0

1 2 3 4

Regulates the water flow required for cooling:

1 Moving mould half.

2 Fixed mould half.

3 Fixed platen.

4 Hopper area.

The zones should be regulated so as to obtain a minimum amount of water consumption, in relation to the
temperatures needed for each zone for the production cycle.
The water flow, for cooling the hydraulic oil, is regulated automatically by an electro-valve.
If the oil temperature exceeds 60C, alarm 020 OIL OVER HEATED is activated or 108 INVERTER OVER
HEATED.

C-0070
C BABYPLAST 6/10P

C.6/ Touch-Screen display - Synoptic diagram

The touch-screen display, other than allowing access to the various functions and parameters of the machine,
also indicates the activation of hydraulic movements, the acivation of the motor and the heaters, the opening of
guards and gate and the opening and closing of the mould.

1 MAIN MENU

2 H1 200 H2 200 H3 200 H4 OFF

3
23 22 21 20 19
4

5 000.0mm

00.0mm
6

8
Gear art. 2345
9

10 11 12 13 14 15 16 17 18

1. Page visualised.
2. Actual temperatures - H1 plastif. - H2 Chamber - H3 Nozzle - H4 Mould.
3. If present, indicates that the motor is ON.
4. Mould position.
5. Indicates that left clamp guard is open
6. This group of three arrows indicates that the mould is closing in HIGH PRESSURE and that the hydraulic
valve has been activated.
7. Indicates the closing or opening of the mould and that the corresponding hydraulic valve has been activated.
8. Indicates activation of ejectors and that the hydraulic valve has been activated.
9. Icons: touch to activate corresponding function.
10. Indicates the name of the tool setting programme in use.
11. Mould heater active: Red -temperature within tolerance band, Yellow - temperature in stand-by.
12. Two dark squares indicate that the mould is closed.
13. Chamber heater active: - Red -temperature within tolerance band, Yellow - temperature in stand-by
14. Indicates the injection carriage forward movement and that the hydraulic valve has been activated.
15. Indicates injection in progress and that the hydraulic valve has been activated
16. Indicates decompression in progress and that the hydraulic valve has been activated.
17. Indicates injection carriage backward movement and that the hydraulic valve has been activated.
18. Injection piston position
19. Indicates activation of plastification and that the hydraulic valve has been activated.
20 Plastification heater active: - Red -temperature within tolerance band, Yellow - temperature in stand-by
21. Indicates that the right injection guard is open.
22. Nozzle heater active - Red -temperature within tolerance band, Yellow - temperature in stand-by
23. Indicates that the tranparent gate is open.
C-0080
BABYPLAST 6/10P C
C.7/ STARTING THE MACHINE

The machine is now ready to be started. Check that it has been filled with oil to the correct level, and
that it is connected to the mains correctly.After switching on at the main switch, the SAFETY GUARD CHECK
must be carried out In order to continue. Before being able to start the motor, the safety guards must be
opened and closed. If a fault is detected with any of the guard switches, it will not be possible to start the
machine. Carry out the following procedures before starting the injection process:

FIRST:
Install the mould and set the mould closed position, following the instructions in section
D1.6/ SETTING THE MOULD CLOSED POSITION.

SECOND:
Set the plastification temperature according to the specifications indicated by the manufacturer of the
material to be injected. Set the injection chamber temperature to approximately 5/10 C below the
plastification temperature parag. D.1.7a TEMPERATURE SETTINGS (page D0090)
WARNING: Plastic material, which was used for tests during the manufacturing process, will be found in the
INJECTION UNIT. MAKE SURE that this material is compatible with the temperatures at which the machine
is to be programmed.
If the user is not experienced in the transformation of thermoplastic materials, it is advisable to begin with a
material with a wide temperature range, such as POLYPROPYLENE, POLYSTYRENE, POLYETHYLENE
ABS,etc.so as to obtain best results right from the start.

THIRD:
Set the shot size based on the volume of the part, the cooling time between 2 and 4 seconds, the 1st
injection pressure at approx. 50/60 bar and a time for the 1st injection pressure depending on the volume of
the part to produce and the density of the material used (start with 1.5 - 3 seconds for example).
Decompression should be set between 1 and 2 mm Parag. D.1.7b4 INJECTION SETTINGS (page D-0140)

FOURTH:
Set sprue break time, if required, from 0.1 to 0.2 secs. see INJECTION CARRIAGE TIME parag. D1.7b1
(page D-0110). Set the opening stroke depending on the size of the part, see parag. D1.7b5 (page D-0150) and
finally, set the ejection time from 0.2 to 0.7 secs. with 2 or 3 ejector strokes. parag. D.1.7b3 (page D-0130).

FIFTH
Close the material chute on the hopper and load the hopper with material as required. When the various,
previously set, temperatures have been reached, open the material chute on the hopper and purge the
machine according to section D.2.3 PURGE page D-0240).
The machine is now ready to produce parts.

SIXTH
Put the machine in semi-automatic mode and make sure that the transparent gate and guards are
closed. Press the START key. The machine will proceed to complete one cycle. The nozzle may cool slightly,
during the first shots, as it comes into contact with the cold mould. If so, for the first shots only, increase the
nozzle temperature by approximately 5 or 10%.
If good results have been achieved, repeat this process several times in SEMI-AUTOMATIC mode, adjusting
the different machine parameters such as times, temperatures, pressures and material load etc.
When in AUTOMATIC mode, make sure that, at the end of the injection cycle, the injection piston reaches a
point less than 3 mm (cushion) within 8 cycles, otherwise the machine will go into alarm. To modify settings
see parag. D.4c ADVANCED SETTINGS (page D-0380)

The parameters quoted in this section are only a guide line, because the various parameters and settings
always depend on the material used, the mould construction and the volume of the part etc.

WARNING: Some plastic materials maybe inflammable and/or explosive.

C-0090
BABYPLAST 6/10P D
D BABYPLAST 6/10P

D.1/ MENU
D.1.1/ Display

Menu open MAIN MENU

Motor status
F8
Clamp position

Synoptic diagram

moviment 000.0mm F7
indicators
00.0mm
Injection position

Tool setting
programme in use
F6
PROGRAMME IN USE
Function key icons

F1 F2 F3 F4 F5

D-0010
BABYPLAST 6/10P D
D.1.2/ ICONS - Description of functions

Switch ON the motor. Information/upgrade


software
Switch OFF the motor upgrade software
Display/CPU

Timer for starting motor Mould closed position

Access to tool settings Save mould setting data

Access to machine Overwrite or change


configurations mould settings.
Access to machine Access to mould settings
config. - password 1212
Access to manufacturer
Access to mould setting
settings.
files
Save data on USB
Switch heaters ON
memory stick
Retreive data from USB
Switch heaters OFF memory stick
Access to temperatures Part counter
page
Atomatic menu Activate temp. in Stand-by

Deactivate Temp. in
Semi-automatic menu
Stand-by
Quality control
Manual menu
password 1212
Visualise alarm Log file: Cycle time
messages -cushion
Confirm - return to
Save average cycle time
previous page
Clamp in manual or Exit without saving
access to clamp data
Inj. carriage in manual or Mould opening and inj.
access to inj. carriage data carr. in semi-automatic
Plastification inmanual or Start automatic or semi-
access to plast. data automatic cycle
Ejection in manual or Stop automatic or semi-
access to ejection data automatic cycle
Injection in maual or Purge
access to injection data
Times and settings Purge to start cycle

Manual movements to the Purge to end cycle


right - change line
Manual movements to the Core pull
left - change line
Pressed with F1/ F3 closes or Setting times
opens as per programme
Activate airblow in manual
Accesso tastiera
if present
Activate venturi loader

D-0020
D BABYPLAST 6/10P

D.1.3/ START UP - GATE CHECK

After turning the main switch to the 1 (ON) position, the BABYPLAST logo will appear for a few seconds
followed by the following display:

F8

000.0mm F7
00.0mm

F6

F1 F2 F3 F4 F5

The guards and transparent gate should be in the closed position. At this point the user should open the
clamp, injection guards and transparent gate, keep them open for at least 2 secs. and then close them so as
to gain access to the next menu and thus start the machine.
If a fault is detected in the gate swiches, during the functional or sequence checks, the machine will go into
alarm and start up will be prevented. If the gate check is successful, the MAIN MENU will appear on the
screen (see next page)

ATTENTION! If the machine goes into alarm FAULTY GATE or GUARD SWITCH (n 06, 07 or 08) during
the gate check at start up, switch the machine off and then on again. If the machine goes into the same
alarm while the machine is running, reset the alarm and carryout the gate check again but without switching
off the machine.This procedure may be repeated three times after which the machine will go into alarm
FAULTY GATE SWITCH REPEAT GATES. At this point the machine must be switched off and then on again
to reset the the gate check function.

MAIN MENU

F8

000.0mm F7
00.0mm

F6

F1 F2 F3 F4 F5

D-0030
BABYPLAST 6/10P D
D.1.4/ MAIN MENU

Motor status ON
MAIN MENU

F8

000.0mm F7 Motor ON/OFF


00.0mm

Machine
F6 configuration

Go to stored tool
settings

Timer for starting the


F1 F2 F3 F4 F5 motor and heaters

Press F7 to switch on the motor. The motor symbol, in the top left hand corner of the display, will appear
as long as the motor is running. press the same key again to switch off the motor. Keys F1, F2 & F3 are
activated when the motor is switched on.

ATTENTION! If the oil temperature is below the minimum value set by the manufacturer (20C), no
movements will be possible. In order that the oil reaches the correct temperature rapidly, the motor will turn at
full speed.

MAIN MENU

F8

Motor OFF
000.0mm F7
00.0mm

F6 Machine
configuration
Mould setting Gear - art. 2345
programme in use
Access to stored
mould settings

F1 F2 F3 F4 F5

Manual menu Automatic menu Switch heaters ON

ATTENTION! The heating elements are switched on by pressing key F3. The setting values will be taken from
those stored in the tool setting programme indicated in the synoptic diagram.

D-0040
D BABYPLAST 6/10P

D.1.5/ MANUAL MENU

While in the MAIN menu, press F1 to enter the MANUAL menu.


The following display will appear:

MANUAL MENU

F8

Back to previous
F7
display

F6 Temperatures

F1 F2 F3 F4 F5

Clamp Injection carriage Plastification Injection Ejection

To activate the various movements in manual, press one of the keys to select the function required. Having
entered the function required, press one of the two keys for backward or forward movements.

For the menu MANUAL: CLAMP see following page.


For the menu MANUAL: EJECTION F3 will activate the optional valve for AIR BLOW if installed.

ATTENTION! For plastification and injection, piston movement will only be possible when the set
temperatures have been reached. ( See tolerance band - user data input ).

WARNING: WHEN CHANGING FROM ONE MATERIAL TO ANOTHER, LOADING A DIFFERENT


MOULD SETTING PROGRAMME OR IN CASE OF RESIDUE MATERIAL LEFT IN THE
SYSTEM FROM PREVIOUS PRODUCTION, GREAT CARE MUST BE TAKEN TO SET
THE CORRECT PROCESSING TEMPERATURES ACCORDING TO THE MATERIAL
MANUFATURERS DATA SHEET. FAILURE TO DO SO MAY CAUSE DAMAGE,
BLOCKAGE, OR GAS; PARTICULARLY DURING PURGING.

D-0050
BABYPLAST 6/10P D
D.1.5a/ MANUAL MENU : CLAMP

MANUAL CLAMP OPEN MANUAL: CLAMP


F1 Speed set by manufacturer (30%)

Pressed together with keys F1or F3


F8
F2
allows the opening and closing of the
clamp at the speed set in the tool setting
programme in use (see diagramme at
bottom of page D1). F7

F3 MANUAL CLAMP CLOSE


Speed set by manufacturer (30%)
F6
F4 CLAMP DATA - please see
below

F5 Set MOULD CLOSED POSITION


- please see following page

F1 F2 F3 F4 F5

When in the menu MANUAL CLAMP press F4 to gain access to the menu for CLAMP TIMES AND
SETTINGS:

To vary values, touch window and


rotate dial

The maximum value depends on the


CLAMP TIMES AND SETTINGS
thickness of the mould

Maximum pressure for the low Opening stroke 055.0 mm F8


pressure clamp piston. Clamp pressure 050 bar
Mould safety 035 bar
Maximum pressure allowed for the
low pressure clamp piston inside the Mould safety range 2.0 mm F7
mould safety control range (next Closing speed 1 070 %
line). If too high 034 mould safety
Closing speed 2 020 %
alarm
Change closing speed 030 mm
Mould safety control range:from the Opening speed 1 075 %
distance set in mm to the 0 mould
closed position.

Save values in mould


See following diagramme where: V100% V1 F8
setting programme in
V1: Closing speed 1 use
50% V2
V2: Closing speed 2 F7 Confirm and exit
P : Closing speed changing point
0 : Mould closed position
D1 Q 0 mm

D-0060
D BABYPLAST 6/10P

D.1.6/ SETTING THE MOULD CLOSED POSITION

Install the mould, making sure that it is positioned correctly. Ensure that it is firmly fixed in place and connect
the ejection return pin to the ejection piston, using an M4 screw. While in the MAIN menu, press F1 to
enter the menu for mould closure in manual. Press F3 to close the mould

till it is completely closed and then F5 to confirm the mould closed position.
Touch the icon so that the numeric keypad appears, digit the password 1212 and confirm.

Mould closed

MANUAL: CLAMP

F8

000.0mm F7
00.0mm

M
F6
Back to previous
display

Confirm mould
F1 F2 F3 F4 F5 closed position

ATTENTION! Ensure that both the symbols on the synoptic diagram, which indicate the mould closed status,
turn dark grey only when the mould is fully closed. The point at which the two symbols turn dark grey, is
the point at which the consensus is given for mould CLOSURE IN HIGH PRESSURE.
If the two symbols do not turn grey, after the mould has reached the mould closed position, the machine will
go into alarm 034 MOULD SAFETY.

N.B. It is possible to vary the mould safety settings and sensitivity range etc. See page D. 0320 paragraph
D.3.3e.

D-0070
BABYPLAST 6/10P D
D.1.7/ AUTOMATIC MENU

MAIN MENU

F8

000.0mm F7 Motor OFF


00.0mm

Machine
F6 configuration
Mould setting Gear - art. 2345
programme in use
Access to stored
mould settings

F1 F2 F3 F4 F5

Manual menu Automatic menu Switch heaters ON

ATTENTION! By pressing F3 the heaters will be switched ON and the active zones will be shown in yellow during
pre-heating and red when the respective tolerance bands have been reached; The settings will be taken from
those saved in the mould setting programme highlighted in the synoptic diagramme.

While in the MAIN menu, press F2 to gain access to the AUTOMATIC menu.The following display will
appear:

AUTOMATIC MENU Actual temperatures


H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7 Return to previous


display
00.0mm

Temperatures
F6
Gear - art. 2345
Times and other
settings

F1 F2 F3 F4 F5

Automatic cycle Semi-auto. cycle Purge Part counter


ATTENTION! Plastification and injection piston movements will only be possible
when the set temperatures have been reached. ( See tolerance band - users menu,
data input ). If an Automatic, Semi-automatic or purge cycle is selected, and the
machine has not reached the the set temperatures, the machine will go in alarm.
D-0080
D BABYPLAST 6/10P

D.1.7a/ AUTOMATIC MENU - SETTING TEMPERATURES

Yellow : indicates that the heaters in the


relative zones are in pre-heat mode or
standby
Red that the heaters in the relative tones
AUTOMATIC MENU are within the tolerance bands
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

F6 M
Gear - art. 2345

F1 F2 F3 F4 F5

While in the AUTOMATIC menu press F6 to gain access to the TEMPERATURES menu:

Oil - reading only Values set Actual values Save values in the mould
settings programme in use
TEMPERATURES
Oil 045 C
H1 200 C 200 C Plastific. F8
H2 200 C 199 C Chamber
H3 195 C 195 C Nozzle
F7
H4 0 514 C Mould

M
F6
Confirm and exit without
saving values set.

STAND-BY Temperature.
It is possible to activate or
F1 F2 F3 F4 F5 deactivate stand-by. If
active, the zones will be
It is only possible to activate or deactivate the zones from shown in yellow on the
the pages of the mould setting programme.see page D-330 synoptic diagramme in the
main menu.

SETTING: Touch zone, which needs to be changed, in the field Values set. Rotate the dial M to set the value
required. Press F7 to return to the previous page. The modified values are changed but not saved in the mould
setting programme in use
The modified values can be saved in the mould setting programme by pressing F8 .

D-0090
BABYPLAST 6/10P D
D.1.7b/ AUTOMATIC MENU - TIMES AND SETTINGS

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

While in the automatic menu press F5 to gain access to the menu for TIMES and SETTINGS, the
following display shows readings only and cannot be modified:

TIMES AND SETTINGS


Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

D-0100
D BABYPLAST 6/10P

D.1.7b1/ INJECTION CARRIAGE SETTINGS

TIMES AND SETTINGS


Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS menu, press F1 to gain access to
INJECTION CARRIAGE TIMES AND SETTINGS :

INJECTION CARRIAGE TIMES AND SETTINGS


By setting a value other than 0
( from 0.3 to 0.6), the injection
carriage moves back and away from Injection carr. time 0.0 sec F8
the mould at each cycle. If the setting Inj. carriage seed 100 %
is 0 sec the injection carriage will
remain against the mould during
each cycle F7

Varies the speed of the injection


carriage. F6

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

D-0110
BABYPLAST 6/10P D
D.1.7b2/ SETTINGS - PLASTIFICATION

TIMES AND SETTINGS


Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS menu press F2 to gain access to
PLASTIFICATION TIMES AND SETTINGS :

To use with 16/18mm diam. injection PLASTIFICATION TIMES AND SETTINGS


pistons. Serves for activating a double
plastification so as to fill completely 2nd shot load time 0.0 sec F8
the above mentioned pistonsi.Setting
a value, e.g. 5 sec, the plastification Plastification speed 100 %
is activated for this time and then
reactivated for a second time so as to F7
reach the material load set.

Varies the plastification piston speed. F6


Suction time 0.5 sec
OPZIONAL : If present, the VENTURI
LOADER can be activated or
deactivated by pressing F6.
If the suction time is 0, suction will
stop when the sensor, installed in the
hopper, detects the presence of
material.
Otherwise, if a value is set which is higher than 0, suction will continue after the sensor has detected material, for
the time set. After 3 cycles of loading without activating the sensor, (no material present) the function deactvates.
Press F6 to reactivate.
ATTENTION: for a correct function use dried air.

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

D-0120
D BABYPLAST 6/10P

D.1.7b3/ SETTINGS - EJECTION

TIMES AND SETTINGS


Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS MENU pressF3 to gain access to
EJECTION TIMES AND SETTINGS:

EJECTION TIMES AND SETTINGS


Varies the ejection piston speed
Ejection speed 100 % F8
N of ejector strokes ( max 10) Number of strokes 2
Ejection pressure 80 bar
Reducing this value reduces the F7
Ejection time 0,20 sec
distance the ejector piston moves.
Ejection return time 0,25 sec
Air blow time 0,0 sec
F6
Ejection pause 0,0 sec
Pause end of cycle 0,0 sec

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

D-0130
BABYPLAST 6/10P D
D.1.7b4/ SETTINGS - INJECTION

TIMES AND SETTINGS


Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS MENU press F4 to gain access to INJECTION TIMES AND
SETTINGS:

Set the shot size in order to obtain a INJECTION TIMES AND SETTINGS
cushion value less than 3 mm (pre-set
parameter). Maximum value 60mm - The Shot size 29.0 mm
shot size depends on the pison size Cooling time 4.5 sec
installed.
1st injection pressure 90 bar
1st pressure time 2.0 sec
When the set time has been reached the
mould opens but except in the case that 2nd injection pressure 30 bar
plastification has not finished. 2nd pressure time 1.0 sec
ATTENTION: To obtain a constant cycle
time, set a value greater than the max. time Decompression 0,0 mm
needed to load the injection piston.

Injection speed 075 %


Injection time, in which the value of the
1st injection pressure. must be reached 2nd injection speed 50 %
otherwise the machine will go into alarm Second speed point 2,0 mm
107 PEAK NOT REACHED.
If the second pressure is activated at a point
set in mm (see page D-0310) the line 2nd ATTENTION: to see all the lines, move the
pressure setting : 00.0mm will be seen. cursor

When the injection piston reaches the


point set, the second injection speed
is activated.

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

D-0140
D BABYPLAST 6/10P

D.1.7b5/ SETTINGS - CLAMP

TIMES AND SETTINGS


D
Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS MENU press F5 to gain access to CLAMP TIMES AND
SETTINGS :

The maximum value depends on the


CLAMP TIMES AND SETTINGS
thickness of the mould

Maximum pressure for the low Opening stroke 055.0 mm F8


pressure clamp piston. Clamp pressure 050 bar
Mould safety 035 bar
Maximum pressure allowed for the
low pressure clamp piston inside the Mould safety range 2.0 mm F7
mould safety control range (next Closing speed 1 070 %
line). If too high 034 mould safety
alarm Closing speed 2 020 %
Change closing speed 030 mm
Mould safety control range:from the Opening speed 1 075 %
distance set in mm to the 0 mould
closed position.

See the following diag. where: V100% V1 F8 Save values in mould


setting programme in use
V1: Closing speed 1
V2: Closing speed 2 50% V2 F7 Confirm and exit
P : Closing speed changing point
0 : Mould closed position
D1 Q 0 mm

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

D-0150
BABYPLAST 6/10P D
D.1.7b6/ SETTINGS - QUALITY CONTROL

By setting a tolerance band, it is possible to monitor two parameters on the machine: The CYCLE TIME and
CUSHION, for which it is possible to see the last 20 cycles.

TIMES AND SETTINGS


D
Actual cycle time 12.0 sec
Actual cushion 1.2 mm F8
Average actual time 12.0 sec
Average time saved 12.0 sec
F7
Quality control NO M
Cycle time error 05 %
F6
Cushion error 1.0 mm Return to previous display

F1 F2 F3 F4 F5

From the MAIN TIMES AND SETTINGS menu, press F6 to gain access to
QUALITY CONTROL . The following display shows readings only and cannot be modified:

QUALITY CONTROL
Quality control NO
Cycle time error 10 % F8
Cushin error 1,0 mm
N of initial cycles 10
F7
N cycles for alarm 20
M
Actual cycle time 15,0 sec
Actual avarage time 15,0 sec F6
Avarage time saved 15,0 sec Confirm and exit
Actual cushion 0,0 mm

F1 F2 F3 F4 F5
Data log CYCLE TIME
and CUSHION

To modify the quality control parameters press F6 and then in the next display enter the
passcode 1212 to gain access to the following menu:

D-0160
D BABYPLAST 6/10P

continued....../ SETTINGS - QUALITY CONTROL

QUALITY CONTROL Confirm and save data in the mould


Quality control NO settings programme.
Cycle time error 10 % F8
Cushin error 1,0 mm
Confirm and exit without saving data
N of initial cycles 10
in the mould settings programme.
F7
N cycles for alarm 20
Actual cycle time 15,0 sec
Actual avarage time 15,0 sec
F6
Avarage time saved 15,0 sec
Actual cushin 0,0 mm

F1 F2 F3 F4 F5

Touch the field to be modified, vary the values by rotating the dial. Press F8 to save the changes in the
mould setting programme in use. By pressing F7 the values will be changed but not saved in the mould
setting programme.

The Quality control function can be activated or deactivated by selecting YES or NO in the first line. press
F8 to save and activate the required error value in the programme in use. Press F4 to save the
t
average cycle time in the programme in use. The quality control function will not be activated until the number
of cycles, set in N of initial cycles, has been reached. The first cycle, after these initial cycles, will be
used for reference by the quality control function. If the machine detects a percentage of variation which is
more than that allowed, compared to the reference cycle, for a number of cycles greater than that set in line -
N of cycles for alarm, the machine activates alarm 048 cycle time out of tolerance.

OPTIONAL: On request it is possible to have an output which is activated each time a cycle is out of
tolerance, and which can be used to activate a PART REJECT device. The machine, in this case, will be
able to reject parts produced which are out of tolerance and will stop, in alarm, when the value of N
CYCLES FOR ALARM has been reached.

ATTENTION! Each time the settings are modified, a new set of initial cycles is run and hence a
new reference cycle is obtained.

D-0170
BABYPLAST 6/10P D
D.1.7b6a/ QUALITY CONTROL - Log File

QUALITY CONTROL
Quality control NO
Cycle time error 10 % F8
Cushin error 1,0 mm
N of initial cycles 10
F7
N cycles for alarm 20
Actual cycle time 15,0 sec
Actual avarage time 15,0 sec F6
Avarage time saved 15,0 sec
Actual cushion 0,0 mm

F1 F2 F3 F4 F5

To see the last 20 CYCLE TIMES and CUSHION values, press F3 to see the following
display:

Last cycle registered LOG FILE


n Cycle Cushion
1 25 0.12 F8
2 25 0.12
3 25 0.12
4 25 0.12 F7
5 25 0.12
6 25 0.12
7 25 0.12 F6
8 25 0.12
9 25 0.12

ATTENTION: to see all the lines, move the


cursor

D-0180
D BABYPLAST 6/10P

D.2./STARTING A CYCLE
D.2.1/ STARTING AN AUTOMATIC CYCLE

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

From the AUTOMATIC MENU press F1 to gain access to the AUTOMATIC CYCLE menu:

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

Press F2 to start the machine in an AUTOMATIC CYCLE

ATTENTION! If the temperatures have not reached the tolerance bands, it will not be possible to start the
automatic cycle and the machine indicate this with an alarm message without, however,
switching off the motors and heaters.The alarm will deactivate when the operating
temperatures have been reached

D-0190
BABYPLAST 6/10P D

When the machine is in an AUTOMATIC CYCLE, the following display will be seen:

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

While the machine is in operation, the following fuctions will be available:

Press F1 :Go directly into a SEMI AUTOMATIC CYCLE without stopping the machine

Press F2 :The machine finishes the cycle in course and then stops.

Press F4 :To see the number set in the part counter and also check and reset the number
reached.

Press F5 :To see and modify times and other settings.

Press F6 :To see and modify temperatures.

D-0200
D BABYPLAST 6/10P

D.2.2/ Start a SEMI AUTOMATIC cycle

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

From the AUTOMATIC MENU press F2 to gain access to the SEMI AUTOMATIC CYCLE menu:

SEMIAUTOMATIC
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

Press F2 to start a SEMI AUTOMATIC CYCLE.

Press F3 : The mould opens completely and the injection carriage and nozzle move away from
the mould.

ATTENTION! If the temperatures have not reached the tolerance bands, it will not be possible to start the
automatic cycle and the machine indicate this with an alarm message without, however,
switching off the motors and heaters.The alarm will deactivate when the operating temperatures
have been reached.

D-0210
BABYPLAST 6/10P D

When the machine is in a SEMI AUTOMATIC CYCLE, the following display will be seen:

SEMI AUTOMATIC
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

While the machine is in operation, the following fuctions will be available:

Press F1 :Go directly into a SEMI AUTOMATIC CYCLE without stopping the machine

Press F2 :The machine finishes the cycle in course and then stops.

Press F4 :To see the number set in the part counter and also check and reset the number
reached.

Press F5 :To see and modify times and other settings.

Press F6 :To see and modify temperatures.

D-0220
D BABYPLAST 6/10P

D.2.3/ Starting a PURGE CYCLE

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

F6
Gear - art. 2345

F1 F2 F3 F4 F5

From the AUTOMATIC MENU press F3 to gain access to the PURGE CYCLE menu:

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

F6
Gear - art. 2345

F1 F2 F3 F4 F5

Press F1 To start PURGE AT END OF CYCLE. At the end of this cycle the injection piston will stop in
the fully forward position hence the cylinder will be empty.
Press F2 To start PURGE AT BEGINNING OF CYCLE. At the end of this cycle the injection cylinder
will be loaded with the quantity of material set in the programme.

ATTENTION! If the temperatures have not reached the tolerance bands, it will not be possible to start the
automatic cycle and the machine indicates this with an alarm message without, however,
switching off the motors and heaters.The alarm will deactivate when the operating temperatures
have been reached

WARNING: WHEN CHANGING FROM ONE MATERIAL TO ANOTHER, LOADING A DIFFERENT MOULD SETTING PROGRAMME
OR IN CASE OF RESIDUE MATERIAL LEFT IN THE SYSTEM FROM PREVIOUS PRODUCTION, GREAT CARE
MUST BE TAKEN TO SET THE CORRECT PROCESSING TEMPERATURES ACCORDING TO THE MATERIAL
MANUFATURERS DATA SHEET. FAILURE TO DO SO MAY CAUSE DAMAGE, BLOCKAGE, OR GAS;
PARTICULARLY DURING PURGING.
D-0230
BABYPLAST 6/10P D

D
When the machine is running in the PURGE CYCLE, the following display will be seen:

PURGE
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

M
F6
Gear - art. 2345

F1 F2 F3 F4 F5

While the machine is running the following options will be available:

Press F3 : The machine will finish the cycle in course and then stop.

Press F6 : To visualise and modify temperatures.

At the end of 6 purge cycles, the machine will stop automatically and remain in idle until either another purge
cycle is started (see previous page) or another function is selected.

D-0240
D BABYPLAST 6/10P

D.2.4/ AUTOMATIC MENU - SETTING UP THE PART COUNTER

AUTOMATIC MENU
H1 200 H2 200 H3 200 H4 OFF
F8

000.0mm F7
00.0mm

F6
Gear - art 2345

F1 F2 F3 F4 F5

From the AUTOMATIC MENU press F4 to gain access to the PART COUNTER menu:

Settings Exit without saving

PART COUNTER

Parts to produce 0 F8

F7
Parts produced 000000
Nunber of cavities 2

Reset F6

Confirm and exit

Reset part counter (line - parts


produced).

ATTENTION! Ensure that the number of cavities shown corresponds to the actual number of cavities in the
mould.The number of cavities shown, corresponds to the number of cavities set in the mould
settings programme in use. To modify, return to the MAIN MENU and press key F5 to enter
the mould settings programme.
By setting the value of parts to produce to 000000 the part counter is excluded and the
machine will produce continuously. To zero the part counter rapidly, select the first digit on the left
and change to zero. All the other digits will change to zero automatically.

D-0250
BABYPLAST 6/10P D
D.3/ MOULD SETTING PROGRAMMES
D.3.1/ LOADING A MOULD SETTING PROGRAMME

MAIN MENU

F8

000.0mm F7
00.0mm

F6
Gear - art. 2345

F1 F2 F3 F4 F5

When in the MAIN MENU press F5 to gain access to the following display:

PROGRAMMES Exit without saving

F8
Confirm mould setting
Programme selected programme selected
F7
Gear - art. 2345 Retrieve programmes from
a USB memory stick

F6 Save programmes onto a


USB memory stick

Access to mould setting


programme selected.

F2 F3 F4 F5 Access to the mould


F1
setting programme folder

To select a new mould setting programme, go to the mould setting programme folder by pressing F1 .
The following display will be seen (see the following page):

D-0260
D BABYPLAST 6/10P

Go back a directory level

/home/root/Fm607/progs Return to the programmes


page
Gear - art. 1111 Gear - art. 2345
Gear - art. 422 Plug - art. 4459 Programme selected
Plug - art. 2222

Keypad to change name

Exit and confirma programme


selected

file Plug - art. 4459 Exit without confirming


filter

Eliminate programme
selected

Touch the file to be selected, the name will be seen in the field file. touch the icon to exit and confirm.

WARNING: WHEN CHANGING FROM ONE MATERIAL TO ANOTHER, LOADING A DIFFERENT MOULD SETTING PROGRAMME
OR IN CASE OF RESIDUE MATERIAL LEFT IN THE SYSTEM FROM PREVIOUS PRODUCTION, GREAT CARE
MUST BE TAKEN TO SET THE CORRECT PROCESSING TEMPERATURES ACCORDING TO THE MATERIAL
MANUFATURERS DATA SHEET. FAILURE TO DO SO MAY CAUSE DAMAGE, BLOCKAGE, OR GAS;
PARTICULARLY DURING PURGING.

D-0265
BABYPLAST 6/10P D
D BABYPLAST 6/10P

D.3.2/ Create or modify mould setting programmes

From the MAIN MENU press F5 to gain access to the following display:

PROGRAMMES Exit without saving

F8
Confirm and exit
Programme selected
Retrieve mould setting
F7
programmes from a USB
Plug - art. 4459
memory stick

F6 Save mould setting


programmes onto a USB
memory stick
To gain access to a mould
settings programme.

F1 F2 F3 F4 F5 Access to mould setting


programme folder

Press F2 to enter the mould setting programme selected.

PROGRAMME: Plug - art 4459


Programme selected
Customer xxx
F8
Material POM
Part weight 0,0 gr Exit without saving
Shot weight 0,0 gr
F7
Mould number 000 Save /Copy cycle
programme
Average time saved 10.4 sec
F6 Setup core pulls
Last modification 01.01.2008

Set temperatures

General settings
F1 F2 F3 F4 F5

Touch the field to be modified, to vary the alphanumerical values, touch the icon keypad for the other
values rotate the dial. Press F7 to save the changes in the mould setting programme in use or to copy the
changes into a new mould setting programme. The value Average time saved can only be saved in the
QUALITY CONTROL function. While the date in Last modification , is saved automatically the moment the
last modification is made.

Press F1 to gain access to the following display:


D-0270
BABYPLAST 6/10P D
D.3.2a/ Mould setting programmes - INJECTION
CARRIAGE

MAIN TIMES AND SETTINGS

F8

F7

F6

F1 F2 F3 F4 F5

Press F1 to gain access to INJECTION CARR. TIMES & SETTINGS :

By setting a value other than 0 INJECTION CARR. TIMES & SETTINGS


(from 0.3 to 0.6), the injection
carriage moves back and away from Injection carr. time 0.0 sec F8
the mould at each cycle. If the setting Inj. carriage speed 100 %
is 0 sec the injection carriage will
remain against the mould during
each cycle F7

Varies the speed of the injection


carriage. F6

Touch the field to be modified, vary the values by rotating the dial. Press F6 to return to the previous
page without saving. Press F7 to save changes in the mould setting programme in use or to copy the
mould setting programme by changing the name. Press F8 to exit without saving.

D-0280
D BABYPLAST 6/10P

D.3.3b/ Mould setting programmes - PLASTIFICATION TIMES


AND SETTINGS

MAIN TIMES AND SETTINGS

F8

F7

F6

F1 F2 F3 F4 F5

Press F2 to gain access to PLASTIFICATION TIMES AND SETTINGS :

To use with 16/18mm diam. injection PLASTIFICATION TIMES AND SETTINGS


pistons. Serves for activating a double
plastification so as to fill completely
the above mentioned pistonsi.Setting
2nd shot load time 0.0 sec F8
a value, e.g. 5 sec, the plastification Plastification speed 100 %
is activated for this time and then
reactivated for a second time so as to F7
reach the material load set.

Varies the plastification piston speed. F6


Suction time 0.5 sec
OPZIONAL : If present, the VENTURI
LOADER can be activated or
deactivated by pressing F6.
If the suction time is 0, suction will
stop when the sensor, installed in the
hopper, detects the presence of
material.
Otherwise, if a value is set which is higher than 0, suction will continue after the sensor has detected material, for
the time set. After 3 cycles of loading without activating the sensor, (no material present) the function deactvates.
Press F6 to reactivate.
ATTENTION: for a correct function use dried air.

Touch the field to be modified, vary the values by rotating the dial. Press F6 to return to the previous
page without saving. Press F7 to save changes in the mould setting programme in use or to copy the
mould setting programme by changing the name. Press F8 to exit without saving.

D-0290
BABYPLAST 6/10P D
D.3.3c/ Mould setting programmes - EJECTION TIMES AND
SETTINGS

MAIN TIMES AND SETTINGS

F8

F7

F6

F1 F2 F3 F4 F5

Press F3 to gain access to EJECTION TIMES AND SETTINGS :

EJECTION TIMES AND SETTINGS


Varies the ejection piston speed

N of ejector strokes ( max 10) Ejection speed 00 % F8


Number of strokes 2
Reducing this value reduces the Ejection pressure 80 bar
distance the ejector piston moves.
Ejection time 0,20 sec
F7
This function may be activated after Ejection retur time 0,25 sec
installing the ejector sensor onto Air blow time 0,0 sec
the moving platten. The sensor is F6
Ejection pause 0,0 sec
supplied in the accessory pack with
the machine. Activate this function Pause end of cycle 0,0 sec
by selecting YES. The sensor will Ejection sensor NO
detect whether the ejectors have
Out at end of cycle NO
fired or re-entered. In case of fault,
the machine will go into alarm 039
EJECTORS DID NOT FIRE or 040
EJECTORS DID NOT RE-ENTER.
Touch the grey fields to change The values in the white fields can
Only in SEMIAUTOMATIC cycle. the values. The lines in bold be changed, both in the MOULD
If active, at end of SETTING PROGRAMME pages
print can only be changed in
SEMIAUTOMATIC cycle. The and in TIMES AND SETTINGS
the MOULD SETTING
ejectors remain out and re-enter
PROGRAMME pages. pages while the machine is
only when the start key is pressed
running.
for start cycle.

Touch the field to be modified, vary the values by rotating the dial. Press F6 to return to the previous
page without saving. Press F7 to save changes in the mould setting programme in use or to copy the
mould setting programme by changing the name. Press F8 to exit without saving.

D-0300
D BABYPLAST 6/10P

D.3.3d/ Mould setting programmes - INJECTION TIMES AND SETTINGS

MAIN TIMES AND SETTINGS

F8

F7

F6

F1 F2 F3 F4 F5

Press F3 to gain access to the following display:


ATTENTION: to see all the lines, move the
cursor.
Set the shot size in order to obtain a INJECTION TIMES AND SETTINGS
cushion value less than 3 mm (pre-set
parameter). Maximum value 60mm - The Shot size 29.0 mm
shot size depends on the pison size Cooling time 4.5 sec
installed.
1st injection pressure 90 bar

When the set time has been reached the 1st pressure time 2.0 sec
mould opens but except in the case that 2nd injection pressure 30 bar
plastification has not finished.
ATTENTION: To obtain a constant cycle 2nd pressure time 1.0 sec
time, set a value greater than the max. time Decompression 0,0 mm
needed to load the injection piston.

Injection time, in which the value of the Injection speed 075 %


1st injection pressure. must be reached 2nd injection speed 50 %
otherwise the machine will go into alarm
107 PEAK NOT REACHED. Seconnd speed point 0.0 mm
Injection mode Peak
If the second pressure is activated at a point
set in mm (see page D-0310) the line 2nd Accumulator OFF
pressure setting : 00.0mm will be seen.
When the injection piston reaches the point Optional: Activates the output which controls
set, the second injection speed is activated. the hydraulic accumulator (if installed) during
the injection phase.

PEAK: (de-fault) - At the end of injection time and on condition that the 1st injection pressure has been
reached, the machine will change over to the 2nd injection pressure.

POSITION (Pos.) : The 1st injection pressure will be maintained till the position, previously set in the
injection menu, has been reached. At this point, the machine will change over to the 2nd injection pressure

Touch the field to be modified, vary the values by rotating the dial. Press F6 to return to the previous
page without saving. Press F7 to save changes in the mould setting programme in use or to copy the
mould setting programme by changing the name. Press F8 to exit without saving.

D-0310
BABYPLAST 6/10P D
D.3.3e/ Mould setting programmes - CLAMP TIMES AND SETTINGS

MAIN TIMES AND SETTINGS

F8

F7

F6

F1 F2 F3 F4 F5

Press F5 to gain access to the following display:

The number of cavities set, conditions


the part counter
Depends on the mould height. With CLAMP TIMES AND SETTINGS
minimum mould h. 70 (95 increased Number of cavities 2
vers.) the maximum possible is 110mm F8
Opening stroke 055.0 mm
Pressure setting for clamp piston Clamp pressure 050 bar
N.B. the larger piston for high pressure
(6,25 t.) is activated only when the Mould safety 035 bar
mould is in the fully closed position. F7
Mould safety setting 2.0 mm
The maximum pressure allowed for the Mould safety excl. pos. 0.10 mm
clamp piston in low pressure. If reached
the machine goes in alarm 034 Mould Closing speed 1 070 %
safety Closing speed 2 020 %
F6
The alarm in mould closing will be active Change closing speed 030 mm
starting from the position of the mould Mould safety range 0.10 mm
safetyr setting to the position of the
mould safety exclusion setting Opening speed 1 075 %
N.B.Outside this range (mould safety
and mould safety exclusion) the
maximum pressure allowed is the
pressure set in clamp pressure.

his function is used to regulate the The lines in bold print highlight the values which can only
sensitivity of the MOULD CLOSED
be modified in the MOULD SETTING PROGRAMME
position. The range can be set
between approx. 0,03 to pages .
0,3 mm. Change the value to modify The other values can be modified in the respective pages
the setting. both in the MANUAL and AUTOMATIC menu while the
machine is running.

D-0320
D BABYPLAST 6/10P

D.3.4/ Mould setting programmes - TEMPERATURES

PROGRAMME: Plug art. 4459


Programme selected
Customer xxx
F8
Material POM
Part weight 0,0 gr Exit without saving
Shot weight 0,0 gr
F7
Mould number 000 Save /Copy cycle
programme
Average time saved 10.4 sec
F6 Setup core pulls
Last modification 01.01.2008

Set temperatures

General settings
F1 F2 F3 F4 F5

Touch the field to be modified, to vary the alphanumerical values, touch the icon keypad for the other
values rotate the dial. Press F7 to save the changes in the mould setting programme in use or to copy the
changes into a new mould setting programme. The value Average time saved can only be saved in the
QUALITY CONTROL function. While the date in Last modification , is saved automatically the moment the
last modification is made.

Press F2 to gain access to the following display:

ACTIVE zone NON ACTIVE zone

TEMPERATURES

H1 Heater plastif. 215 C % X


F8
H2 Heater inj. chamber 215 C % X
H3 Heater nozzle 215 C % X
H4 Heater mould 215 C % X F7
V1 Cooling fixed platen 0 C % X M
V2 Cooling hopper 0 C % X
V3 Cooling fixed mould 0 C % X
F6
V4 Cooling moving mould 0 C % X
Hotrunner 0

to activate a zone, press directly on the symbol C (% only in case of emergency), then on the corresponding value
field and rotate the dial to set the value required.
press X to deactivate the zone completely.

N.B. : The valves, EV 1-2-3-4 (water manifold) are optional. However, in any case the values can be set as a
reminder using the same values as the water manifold ( 5-10-15-20-25).

D-0330
BABYPLAST 6/10P D
D.3.5/ Mould setting programmes - core pull

PROGRAMME: Plug - art. 4459


Programme selected
Customer xxx
F8
Material POM
Part weight 0,0 gr Exit without saving
Shot weight 0,0 gr
F7
Mould number 000 Save /Copy cycle
programme
Average time saved 10.4 sec
F6 Setup core pulls
Last modification 01.01.2008

Set temperatures

General settings
F1 F2 F3 F4 F5

Press F3 to gain access to the following display:

Indication of the page, Digit the words activate or deactivate to


core pull A or B, activate or deactivate the core pull function
being visualised in the respective page A or B.
Mould closed 5

PROGRAMME
Injection 1
Core pull A Core pull B
F8
Disabled 2
Cooling
Pos Status Time Cons.
1 OFF 0.0 OFF F7 Mould open 3
2 OFF 0.0 OFF
3 OFF 0.0 OFF
Ejection 4
4 OFF 0.0 OFF F6
5 OFF 0.0 OFF
Sch 1

On request, a socket can be fitted for 24V output (output A - J708) (output B - J709) and the two respective PNP
input sockets for cycle consensus (A J306 - BJ307). The two outputs A or B can be activated for an indefinite
length of time when ON is set (status column), and 00s set (time column). The same outputs can also be
activated for specific length of time by setting ON (status column) and a specfic time (time column). When ON is
selected in the cons. column (consensus), the cycle will not start without the input (for consensus to continue)
from an external source.
Positions 1,2,3,4 & 5 represent the positons during the cycle when the outputs A or B will be activated (see
following diagram). This function can also be used to activate a valve for air blow for example.
To activate or deactivate the output A or B, select by touching the relative heading (Core pull A or Core pull B).
D-0340
D BABYPLAST 6/10P

D.3.3/ TOOL SETTING PROGRAMMES - How to copy a programme.

If a new programme has to be created, which is similar to an existing programme, it is possible to copy the
existing programme and make modifications if necessary.
Do as follows:

Example: Programme to copy : Gear A


New pragramme : Gear B

From the main menu press F5 to gain access to the following display:
Exit without saving
PROGRAMMES

F8 Confirm and exit


Programme selected
F7 Retrieve mould seting
Gear A programmes from USB
memory stick
F6 Save mould setting
programmes on a USB
memory stick

To gain access to a mould


settings programme.
F1 F2 F3 F4 F5
Access to the mould setting
programmes folder

Check that the mould setting programme selected is the one to be copied, (to select another programme see page D-
0260) press F2 to enter the programme

PROGRAMME: Gear A
Programme selected
Customer xxx
F8
Material POM
Part weight 0,0 gr Exit without saving
Shot weight 0,0 gr
F7
Mould number 000 Save /Copy cycle
programme
Average time saved 10.4 sec
Last modification 01.01.2008
F6

F1 F2 F3 F4 F5

Press F7 to gain access to the following display: (see following page):

D-0350
BABYPLAST 6/10P D

PROGRAMME: Gear A
Customer xxx
F8
Material POM
Part weight 0,0 gr
Peso stampata SAVE PROGRAMME
0,0 gr
Gear A F7
Numero stampo 000
Save changes in the mould
setting programme in use
Tempo m Yes Change
YESdio salvato Cancel sec
10.4
Change programme name by Last modification 01.01.2008
F6
creating a new programme

Exit without saving

F1 F2 F3 F4 F5

Press Change :

/home/root/Fm607/progs

Gear 1111 Gear 2345


Gear 4422 Gear A
Programme selected
Plug 2222

Key to change name

Confirm and exit


programme selected

file Gear A Exit without confirming


filter

Eliminate programme
selected

Press the icon keypad digit the new programme name (eg: Gear B)
confirm and exit from keypad by pressing . The new programme created will be seen in the field file
( E.g. gear B) press the icon to confirm and exit.

D-0360
D BABYPLAST 6/10P

D.4/MACHINE CONFIGURATION

MAIN MENU

F8

000.0mm F7
00.0mm

F6 Advanced
settings
Gear part. n 2345

F1 F2 F3 F4 F5

From the main menu press F6 to gain access to the following display:

SET UP
15:25:33
February 2008 F8
Sun Mon Tue Wes Thu Fri Sat
1 2 3 4 5 6 7
8 9 10 11 12 13 14 F7
15 16 17 18 19 20 21
22 23 24 25 26 27 28
F6
Manufacturer

Advanced settings User


F1 F2 F3 F4 F5

Press F4 and enter PASSCODE 1212 to gain access to ADVANCED USER SETTINGS:

D-0370
BABYPLAST 6/10P D
D.4a/ MACHINE CONFIGURATION - ADVANCED SETTINGS
Change language - Celsius/Farenheit

From DISPLAY SET UP press F4 and enter the pass code1212 (see previous page) to gain access to
the following display :

MACHINE PARAMETERS
Change language
Language English
Change to Celsius/Farenheit F8
Degrees Celsius
Machine identification number - ( Machine ID number 1
see page D-0410) F7
Meter - Hrs 000045 reset
Meter - hours . every 1500 hours Total hours 000045
there will be a reminder to change
Total cycles 001555
the oil return filter. Press the word F6
reset to reset. Modification with password

Total hours counter. Cannot be


reset.

Total cycles counter. Cannot be


reset. F1 F2 F3 F4 F5

If is selected, the settings


can only be modified by digiting the
user password 1212

Press F3 to see the software versions installed in the 4 microprocessors mounted in the machine.

INFO

F8

F7
Software version display

Software version CPU FMP237 FM607 Sw. Ver.: 1.10 F6


FMP237 FM542 Sw. Ver.: 4.10
Software version - prop. valve FMP237 FM542DSPSw. Ver.: 1.60
FMP000 FM549 Sw. Ver.: 1.01AV
Software version INVERTER

Upgrade software: The icon is only


active if the USB memory stick is
inserted in the USB port on the
machine. ( see page. D-0405)

D-0380
D BABYPLAST 6/10P

D.4b/ MACHINE CONFIGURATION - ADVANCED SETTINGS -


TEMPERATURES

From DISPLAY SET UP press F4 and enter the pass code 1212 (see previous page) to gain access
to the following display:
MACHINE PARAMETERS
Change language
Language English
Change to Celsius/Farenheit
F8
Degrees Celsius

Machine identification number - Machine ID number 1


(see page D-0410) F7
Meter - Hrs 000045 reset

Meter - hours . every 1500 hours Total hours 000045


there will be a reminder to change
Total cycles 001555
the oil return filter. Press the word F6
reset to reset. Modification with password

F1 F2 F3 F4 F5

Press F4 to gain access to Machine parameters TEMPERATURES:

The value set, will be the toleranceband for the TEMPERATURES


temperature in use. If the operating temperature
increases or decreases by a value greater than Tol. band max. error 25 C
this set temperature, (i.e. goes out of the tolerance
band) the machine goes into alarm Tol. band max Temperature in stand-by 80 %
error. Manual operation of the injection piston and Timeout for alarm 3 min
plastification will not be possible nor will it be Pre-heating time 180 sec
possible to enter an automatic cycle until the
operating temperatures are within this tolerance
band.

The stand-by temperature always depends on


the temperatures set in each of the mould
setting programmes and when active, the
heater zones will be seen in yellow. The stand-
by temp. activates in the following cases:
1.When the heaters are switched on in
automatic.
2.When the machine is in alarm for a greater
length of time than the time out alarm. When the heaters are switched on, they will
3.When the heaters are switched on manually. remain at the stand-by temperature for the
length of time set for pre-heating time

If the machine is in alarm for a time greater


than that set fo time out alarm, the heaters
will go into the stand-by mode. After double
the length of time, the heaters and motor will
be switched off.

Touch the field to be modifed, change the value by rotating the dial.

ATTENTION: If the actual temperatures exceed by more than double the value set in Tol. band max. error, the
machine will go in alarm 112..116 OVER TEMPERATURE.. - Motor and heaters will be switched off.
D-0390
BABYPLAST 6/10P D
D.4c/ MACHINE CONFIGURATION - ADVANCED SETTINGS -
TIMES AND SETTINGS

From display set up press F4 and enter the pass code 1212 (see previous page) to gain access to
the following display:
MACHINE PARAMETERS
Change language
Language English
Change to Celsius/Farenheit
F8
Degrees Celsius

Machine identification number - Machine ID number 1


(see page D-0410) F7
Meter - Hrs 000045 reset

Meter - hours . every 1500 hours Total hours 000045


there will be a reminder to change
Total cycles 001555
the oil return filter. Press the word F6
reset to reset. Modification with password

F1 F2 F3 F4 F5

Press F5 to gain access to MACHINE PARAMETERS - TIMES AND SETTINGS:

ATTENTION: The value of 10mm MUST be TIMES AND SETTINGS


set if a 10mm injection piston is installed
on the machine. This setting will limit the
maximum injection pressure to 100 bar. Piston diameter 14 mm

Maximum injection pressure in manual and Injection pressure 60 bar


purge. Cushion 3,0 mm
Maximum cushion. If the cushion is more, Injection incomplete 8
than the value set, for a number of cycles
greater than that set in the line Injection Timeout clamp close 4,0 sec
incomplete (next line), the machine will go Closing speed in manual 30 %
into alarm 036 INJECTION INCOMPLETE
Opening speed 2 NO
If the cushion is more, than the value set in
the previous line (Cushion), for a number of Intrusion programme NO
cycles greater than that set in this line
(Injection incomplete), the machine will go
into alarm 036 INJECTION INCOMPLETE
If the clamp does not reach the 0 mould
position (mould closed) within the set time,
The machine will go into alarm 042 Set date and time
TIMEout mould closed
Clamp speed in manual mode
If NO is set (default): Standard cycle.
Activate / deactivate the second opening If YES is set:Produces a pre-injection.
speed. and a line will appear, in the INJECTION menu,
When active, it will be possible to set the where it will be possible to set a time to activate
point at which the speed changes, in the plastification before the injection phase.
CLAMP TIMES AND SETTINGS menu.

Touch the field to be modifed, change the value by rotating the dial.

D-0400
D BABYPLAST 6/10P

D.4.4/ UPGRADE SOFTWARE

From the page DISPLAY SETTINGS press F4 and insert the assword 1212 (see previous page) to gain
access to the following screen :

Change language MACHINE PARAMETERS


Language English
Change Celsius/Farenheit F8
Degrees Celsius
Machine identification number- Machine ID number 1
(see page.D-0410) F7
Meter 000045 reset
Meter - hours . every 1500 hours Total hours 000045
there will be a reminder to change
Total cycles 001555
the oil return filter. Press the word F6
reset to reset. Modify with password

Total hours counter. Cannot be


reset.

Total cycles counter. Cannot be


reset. F1 F2 F3 F4 F5
If is selected, the settings
can only be modified by digiting the
user password 1212

Peress F3 to see the software versions loaded on the 4 microprocessors fitted to the machine

ATTENTION: Upgrade diplay: The folder FM607, suppplied by the manufacturer, should be
loaded onto a USB memory key
Upgrade CPU: The fileFMP237_FM542Appl_V......mot should be present

Remove the cover found on the bottom side the display, and insert the USB memory stick into one of the two
USB ports as indicated.

D-0405
BABYPLAST 6/10P D

Press F3 to see the software versions loaded onto the 4 micrprocessors fitted to the machine
:
ATTENTION: It is only possible to gain access to the following pages with the motor OFF

INFO

F8

F7
Software version of the Display

Software version of the CPU FMP237 FM607 Sw. Ver.: 1.10 F6


FMP237 FM542 Sw. Ver.: 4.10
Software version of the Prop. valve FMP237 FM542DSPSw. Ver.: 1.60
FMP000 FM549 Sw. Ver.: 1.01AV
Software version of the INVERTER

Software upgrade icon is only active


when the USB memory key is
inserted. ( see page........)

Press F7 to gain access to the following display:

SOFTWARE UPGRADE

F8
Key FM607 (display) to load
upgrade file for the display from the FM607 (Display) Upgrade
USB memory key F7
FM542 (CPU) Upgrade
Key FM542 (CPU) to load
upgrade file for the CPU from the
USB memory key F6

To upgrade software do as follows:

FM607 Display: press the corresponding key, the numeric key pad will apear, digit the password 1122 and
confirm. At the end press F7, remove the USB key switch off the machine at the main
switch and then switch it on again.

FM542 CPU: press the corresponding key, the numeric key pad will apear, digit the password 1122 and
confirm the main directory of the USB key will appear, select the file:
FMP237_FM542Appl_V..... and confirm. At the end press F7, remove the USB key switch
off the machine at the main switch and then switch it on again.

ATTENTION: When upgrading the CPU and Display together, it is possible to swith the machine OFF and
on again at the end of both operations.
D-0406
D BABYPLAST 6/10P

D.5/ USB MEMORY STICK - Saving/downloading

Remove the cover found on the bottom side the display, and insert the USB memory stick into one of the two
USB ports as indicated.

MAIN MENU

F8

000.0mm F7
00.0mm

F6
Gear - art. 2345

F1 F2 F3 F4 F5

From the MAIN MENU press F5 to gain access to the following display:

D-0410
BABYPLAST 6/10P D

ATTENTION: the icons F4 and F5 are only activeif the USB memory stick is inserted into one of
the USB ports.

PROGRAMMES

F8

Programme selected
F7
Gear - art. 2345

F6

F1 F2 F3 F4 F5

By pressing the icon F4, a folder will be created in the USB memory stick called:
BabyFMP237_ID001 this folder will contain ALL the mould setting programme files found in the
machine. ATTENTION :If the folder already exists, any files, contained inside
this folder, with the same name will be overwritten

By pressing F5 all mould setting programmes in the folder BabyFMP237_ID001 will be loaded onto
the machine. ATTENTION the files with the same name will be overwritten.

ATTENTION: do NOT change the name of the folder created , the names of the files inside can be changed, but
not that of the folder otherwise it will not be possible to load the files (mould setting programmes)
not the machine

If more than one Babyplast are owned and in the case that each machine should have its own mould setting
programmes, it is possible to give each Babyplast a different ID number (machine Identification number ( eg: 01
- 02 - 03 ecc.) on the MACHINE PARAMETERS ( see page D-0390).
In this case, even if only one USB memory stick is used, different folders will be created with different names
based on the machine ID number
For example: BabyFMP237_ID001
BabyFMP237_ID002
BabyFMP237_ID003....ecc.
It will be possible to modify the position of files (mould setting programmes) and change their names inside the
various folders via a PC.

D-0420
D BABYPLAST 6/10P

D.5.1/ PRINT AND ELEBORATE MOULD SETTING DATA ON A PC

1. Copy the folder BP_Program_Viewer_v100 into a directory on a PC


2.Open the programme BP_Program_Viewer_v100 found inside.

3.Select Open

4. using browse select the folder BabyFMP237_ID001 where the mould setting programmes (files) have been
previously saved. (see paragraph D.5 page D-0410)

D-0430
BABYPLAST 6/10P D

5. Select the folder Progs and then the mould setting programme (file) required

6. Open

7. Once the mould setting programme (file) has been opened, it will be possible to print it, copy and past it into
another programme (such as Microsoft Word / exel etc) save it in a different format.

D-0440
D BABYPLAST 6/10P

D-0450
BABYPLAST 6/10P D

D-0460
BABYPLAST 6/10P
E BABYPLAST 6/10P

E.9/ ALARMS

N MESSAGE CAUSE ACTION


001 LEFT GUARD OPEN Clamp guard open Close guard and ensure that the
002 GATE OPEN Transparent guard open corresponding indicator, on the synoptic
003 RIGHT GUARD OPEN Injection guard open diag., goes out.
004 MOTOR OVER HEATED The motor has over heated Check the power supply to the motor.

005 OFFSET ANALOG INPUT FAULTY Thermocouple analog inputs Alarm is only present durng testing by
faulty manufacturer
006 FAULTY SWITCH L/H GUARD Faulty guard / gate switch or Swich off at the main switch. Check the
007 FAULTY GATE SWITCH switches are not synchronised position of the magnets in the gate and
008 FAULTY SWITCH R/H GUARD with the hydraulic safety valve. guards.Repeat gate check.
010 EEPROM FM542 ERROR Fault eeprom on CPU Switch machine OFF and then ON
again. If persists contact a technician.
011 INCONSISTENT GATE CHECK Inconsistency in the gate check Swich off at the main switch. Check the
proceedure position of the magnets in the gate and
guards.Repeat gate check.
012 FAULTY THERMOCOUPLE PLATEN
013 FAULTY THERMOCOUPLE HOPPER
014 FAULTY THERMOCOUP. PLASTIF. Thermocouple faulty Check thermocouple, wires and
015 FAULTY THERMOCOUP. INJ. CHAM. connections. Change if necessary.
016 FAULTY THERMOCOUPLE NOZZLE
017 FAULTY THERMO. FIXED MOULD
018 FAULTY THERMO. MOVING MOULD
019 HOPPER OVER HEATED Insufficient cooling at base of Check water flow and the
hopper. If more than 70C, temperature of the cooling system.
machine goes into alarm
020 OIL OVER HEATED Insufficient cooling. Check water flow and the
Temperaturover 60C temperature of the cooling system.
021 FAULTY INTERN. COMPENS. T/C Faulty thermocouple cold joint Contact a technician
compensator on circuit board.
022 FAULTY EXTERN. COMPENS. T/C Faulty thermocouple cold joint Check wires and contacts change NTC
compensator in socket. component.
023 OIL LEVEL LOW Oil level is too low Check for leaks, check oil level float and
connections. Fill tank to correct level.

024 NEUTRAL PHASE MISSING Neutral phase not connected Check power supply connections
026 PHASE MISSING Phase not connected Check power supply connections
027 CURRENT FAULT Check power supply voltage
028 INVERTER ALARM Inverter faulty Contact a technician
029 OIL COLD Oil temperature less than 20C Switch on the motor and / or wait for the
oil temperature to go above the
minimum temperature allowed.
030 FAULTY OIL COMPENS. T/C Oil thermocouple cold joint Check wires and connectioins or
compensator faulty change NTC component
031 EMERGENCY Emergency stop button activated Reset button or check external alarm
or input from external alarm. source.
032 CHANGE FILTER The machine has worked for Change return filter and and reset hour
1500 hrs. metre
033 EJECTORS OUT Trying to start a cycle with Make ejectors return in manual mode.
ejectors out and ejector return Check the M4 x 20 screw which
sensor active. connects the ejector pin in mould to the
ejector piston on machine

E-0010
BABYPLAST 6/10P E
N MESSAGE CAUSE ACTION
034 MOULD SAFETY ALARM 1. Object trapped between two Remove the object which is stopping
the mould halves the mould from closing.
2.Mould safety set too sensitive. Increase Mould safety
(page D-0150)
3.Mould safety range too low Enter the mould setting programme in
use , clamp page (D-320) line mould
safety range increase the value set.

035 RECURENT FAULTY SWITCH 1.Incorrect gate switch sequence. Switch the machine OFF and then ON
2.Magnet missing or not in again.
correct position
036 INJECTION INCOMPLETE The injection piston has not 1. Incomplete or no injection
reached the correct cushion due to a part stuck in the mould cavity
positon (less than 3mm) for 8 or a blocked nozzle.
consecutive cycles see 2.Material load set too high. Reduce
pag.D-380 until cushion is under 3mm.
037 TIMEOUT MATERIAL LOAD Activates if material does not load 1.No material in hopper
within 23 Sec. from the start of 2.Hopper chute blocked
plastification Check hopper or plastification valve
038 TIMEOUT MOULD OPENING Mould does not open or wrong Check mould or min mould open
setting for min. mould opening setting.
039 EJECTORS DID NOT FIRE The ejector sensor is active and 1.Check mould
did not detect ejectors fired. 2.Check position of ejector sensor.
040 EJECTORS DID NOT RE-ENTER The ejector sensor is active and 3.If sensor is not present, deactivate
did not detect ejectors re-entered function. Check screw in eject. pist.
041 MAX CYCLE TIME EXCEEDED Cycle has not been Check at which point in the cycle, the
completed within 90 sec. machine stopped.
042 TIMEOUT MOULD CLOSURE The mould does not close within 1.Increase closing speed / pressure.
3 sec. 2.Increase mould safety pressure.
3.Check for the mould closed
indicators on the synoptic diag.

043 TIMEOUT HIGH PRESSURE No impulse from injection pressure 1.Check the setting of the injection
switch within 3 sec pressure switch and that it functions
from the start of high pressure. correctly. (page F-140 pos. 11)
044 TIMEOUT DECOMPRESSION Decompression point not reached Check the injection valve.
within 3 sec.
045 END OF PRODUCTION BATCH End of production batch. Reset counter / start a new batch.
046 DSP COMMUNICATION PROBLEM Faulty proportional valve Contact a technician.
047 PROBLEM WITH CIRCUIT BREAKER Faulty circuit breaker Contact a technician.
048 CYCLE TIME OUT OF TOLERANCE The quality control function is Check the cause -
activated and the cycle time has Increase the % set for tolerance band.
gone out of tolerance
050 FAULTY MOULD TRANSDUCER Faulty transducer readings Check connections
051 FAULTY INJECTION TRANSDUCER
052 CUSHION OUT OF TOLLERANCE The quality control function is Check the cause / cycle parameters.
activated and the cushion value is Increase the % set for tolerance band.
out of tolerance
054 TIME-OUT CORE PULL A No consensus for core pull check mould and connection of sensors
055 TIME-OUT CORE PULL B
056 CHECK GUARDS AND GATE Guard and gate check not Open guards and gate, wait for at least
completed. 2 secs and then close again.

E-0020
E BABYPLAST 6/10P

Cod MESSAGGIO CAUSA RISOLUZIONE


064 TIME-OUT PLASTIF. HEATER Activates when the heaters do Reset the alarm, switch the machine
065 TIME-OUT INJ. CHAMBER HEATER not reach the set temperature OFF and check heaters and
066 TIME-OUT NOZZLE HEATER within 30mins. connections.
067 TIME-OUT MOULD HEATER (manufacturer setting by default)
068 TIME-OUT MOV. MOULD HEATER
069 TIME-OUT MACHINE STOPPED Activates when machine remains Reset the alarm and switch ON the
with heaters and motor ON, but motor and heaters.
without running a cycle, for more
than 30 mins. (manufacturer
setting by default)
070 AUTO-OFF FOR MACHINE STOPPED Activates after the machine has Reset the alarm and switch ON the
been in alarm for more than 6 motor and heaters.
mins. (user setting page D-0370).
- Motor and heaters are switched
OFF.
071 CONNECTION PROBLEM FM542 Faulty CPU Switch machine OFF and then ON
again. If persists contact a technician.
072 NOT REACHED PLASTIFIC. TEMP. Activates if the heaters have not Exit from Automatic/Semiautomatic/
073 NOT REACHED INJ. CHAMBER TEMP yet entered within the tolerance Purge and wait for the temperatures to
074 NOT REACHED NOZZLE TEMP. bands and the operator attempts enter within the respective tolerance
075 NOT REACHED MOULD TEMP. to use plastification or injection bands
076 NOT REACHED MOV. MOULD TEMP. functions.
077 L/H GUARD OPEN DURING CYCLE
078 GATE OPEN DURING CYCLE Guard / gate open Reset alarm and close guard / gate
079 R/H GUARD OPEN DURING CYCLE
080 ERROR PLASTIFICATION TEMP. Temperatures out of tolerance Check thermocouples and connections.
081 ERROR INJ. CHAMBER TEMP. (+ 0 -) band during cycle.
082 ERROR NOZZLE TEMP.
083 ERROR MOULD TEMP.
084 ERROR MOVING MOULD TEMP.
106 SHORT CIRCUIT PROP. VALVE Faulty proportional valve Switch the machine OFF and ON again
If persists contact a technician.
107 PEAK NOT REACHED Set injection pressure not Increase injection time.
reached Check injection pressure transducer
connections.
108 INVERTER OVER HEATED Inverter temperature has gone Check cooling circuit , valve and
over the operating temperature thermocouple which control the tempe-
allowed. rature.
112 OVER TEMPERATURE PLAST. The actual temperature has gone 1. Set a higher temperature setting that
113 OVER TEMPERATURE CHAMBER out of tolerance by double the is within the tolerance band or wait for
114 OVER TEMPERATURE NOZZLE max imum tol. temp .set (page D- the machine to cool to a suitable
115 OVER TEMPERATURE FIXED MOULD 0390) because: temperature.
116 OVER TEMPERATURE MOV. MOULD 1. A temperature has been 2. Contact a technician.
changed while the machine is still
hotand the new value is out of the
tolerance band by double.
2. A faulty triac or optoisolator
has caused a short circuit in the
heater.
128 DATA LOAD FM542 KO Data load failure while starting Switch machine OFF and then ON
129 DATA LOAD INVERTER KO machine again. If persists contact a technician.
130 COMUNICATION FM542 KO
131 COMUNICATION INVERTER KO
E-0030
BABYPLAST 6/10P E
F/ MAINTENANCE

All the materials used in the construction of BABYPLAST 6/10P have been studied so that
they require minimum maintenance and are easy to replace.

OIL:
The oil and filters must be kept clean and must be replaced within the recommended
periods so that the hydraulic equipment does not wear prematurely.
RECOMMENDED PERIODS FOR OIL CHANGE: = 2000 to 5000 HOURS ( acc. to oil type)
FILTER: = 1500 HOURS

REFRIGERATION UNIT:
If treated water is used, so as to avoid calcium deposits from forming, no maintenance is
required. If treated water is not used, the system will have to be cleaned depending on calcium
level in the water.

MOVEABLE PARTS:
All the moveable parts, that are subject to friction, are lined with TEFLON, including the
mobile platen with the STD bushings, and therefore, apart from the normal cleaning, no
maintenance is required. (However, the wear on the bushings ought to be checked
regularly).

GASKETS:
All the gaskets are fitted with bronze reinforced PTFE friction strips, and O-ring
seal. Check the that the surfaces correspond before joining.

ELECTRICAL EQUIPMENT.
Inspect the ventilator in the electrnics compartment, particularly in hot weather, keep the
unit dry and clean, and make sure the connections are well-maintained. Do not use used
parts when replacing elements, especially where FUSES AND TRIACS are concerned.
Electrical maintenance should be carried out by qualified personel only.

HEATING EQUIPMENT:
Seeing as all the heating elements are standard and the thermocouples are independent,
they are easy to maintain. If other thermocouples are used,they should be a ground
isolated "J"-type to avoid disturbances from electrical noise.

NOZZLE:

The Nozzle has an armoured heating element which is fixed in place by a cup shaped protecive
cover. Keep this assembly as clean as possible and check the condition of wiring regularly for
damage etc.

INJECTION CHAMBER
has two 8 x 80 diameter bulb type 200 W heating elements which need to
be checked regularly. Keep this assembly as clean as possible and check the condition
of wiring regularly for damage etc.

PLASTIFICATION CHAMBER
The plastification chamber is heated by a - 230V 1000W 37mm diam. heater band
which guarantees an optimal and uniform heat distribution which is essential for
technical polymers. Keep this assembly as clean as possible and check the condition
of wiring regularly for damage etc.

F-0010
F BABYPLAST 6/10P

F/ Electrical drawings - Electro-mechanical diagramme

F-0020
BABYPLAST 6/10P F
F/ Electrical drawings - Power connections

F-0030
F BABYPLAST 6/10P

F/ Electrical drawings - Gate switch connections

F-0040
BABYPLAST 6/10P F
F/ Electrical drawings -Outputs

F-0050
F BABYPLAST 6/10P

F/ Electrical drawings -Inputs

F-0060
BABYPLAST 6/10P F
F/ Electrical drawings -Inverter,CPU & Display connections

F-0070
F BABYPLAST 6/10P

F/ Electrical drawings -Euromap 67 connections (optional)

F-0080
BABYPLAST 6/10P F
F/ Electrical drawings board CPU board layout (FM542-1) part n C30901900

F-0090
F BABYPLAST 6/10P

F/ Electrical drawings Power board layout (FM542-2) part n C30902000

F-0100
BABYPLAST 6/10P F
F/ Electrical drawings Display layout (FM607A) part n C30903200

F-0110
F BABYPLAST 6/10P

F/ Electrical drawings inverter (FM549BP) part n C30902300

ATTENTION: When removing this board, do not separate the board from the aluminium
base. Failure to do so may cause serious damage.

F-0120
Connections A-B-C-D-E-F-G-H-I-J-K-L--PRS1-: G1/8

OIL
TANK
Connections P-T-TRS: G1/4

1 1A 1B 1A : INJECTION
I 1B: DECOMPRESSION
BABYPLAST 6/10P

2 10 2 2 :PLASTIFICATION
12

CLAMP
12
3 3
T 3 : EJECTION

4 4A 4B 4A : CLAMP H. P.
P 4B : CLAMP L. P.

5 7 5A 5B 5A : MOULD OPEN

EJECTION
5B: PRES. RELEASE
11
6 11 6A 6B 6A : NOZZLE BACK
9 6B: NOZZLE FORWARD

22 40201900 Safety Valve assembly


21 40201300 Safety Valve assembly 1
20 10000500 Radiator assembly 1

PLASTIFICATION
19 407.2001134 Suction filter 1
18 402.6252710 Maximum pressure reg. DBDS 1
17 407.6801200 Return filter 1
16 40202900 Pump 3,5l 1
15 C30400300 Motor 3 phase - 330V - 50hz 1
14 C10006500 AFT valve 1
13 402.6950200 Pressure gauge 160 bar 2
F/ HYDRAULIC SYSTEM

INJECTION
12 30706800 Pressure transducer 250 bar - 10v 1
11 40203900 Pressure switch 110/107 bar 1
10 OC9001003 Screw M8x8 with diam.0,5mm hole 1
21 9 OC9001053 Screw M6x6 with diam. 0,6mm hole 1
8 043306105600000 Valve VSON.08A 1
HYDRAULIC SAFETY
C40203700 Solenoid S5L35HRL 12VDC 23W Cl.H 1
7
C40203600 Prop. valve VEP5A2R10.77K0604NA 1
15 ES-OD02 Solenoid S8.356HRL.24DC 20W Cl.F 2
F

5
402.2001101 Valve VED8I4306.58K34.44NCD215 1
ES-OD02 Solenoid S8.356HRL.24DC 20W Cl.F 2
2-3
402.2001102 Valve VED8I4206.58K40.30NCC215 2

CARRIAGE
INJECTION
ES-OD02 Solenoid S8.356HRL.24DC 20W Cl.F 6
19 16 1-4-6
402.2001100 Valve VED8I4306.58K32.44NCD215 3
18
PRESSURE 17
Hydraulic diagramme OFEO7806RL0001
OIL TANK 20 BABYPLAST 6/10P
cronoplast sl

F-0140
F-0150
F/ Clamp unit
F

Pos. PART NUMBER DESCRIPTION Q.ty

CRONOPLAST
S.L.
BABYPLAST 6/10P
BABYPLAST 6/10P F
F/ Injection unit

F-0160
F-0170
B

A
F/ Motor - pump assembly drawing
F

A 10003000 Motor - pump assembly


B 10000500 Heat exchanger assembly
BABYPLAST 6/10P

Part n Description
15
BABYPLAST 6/10P

14
13
22 21 20 19 18 17 16
12
1
11
10

9 23
2
8

4
3 0

4
F/ Main parts drawing

5 6 7

N Part n DESCRIPTION N Part n DESCRIPTION


1 30903200 Board Display 13 100.6750310 Heat guard - plastification chamber
2 30702400 Linear Transducer L. 125 mm 14 100.2230110 Hydraulic plastific. cylinder assembly
3 402.6950200 Pressure gauge 15 100.2160110 Hopper
4 30706900 Main switch 16 30301400 Plastification heating element
30707000 Emergency stop 30300500 Chamber heating element 2x8x80
F

5 17
6 500.6300200 Water Manifold 18 20018100 Injection unit assembly
7 ..........
............. Water inlet/outlet 19 302.6651200 Nozzle thermocouple ty J - 3x40
8 302.6651400 Chamber thermocouple 20 30300400 Nozzle heating element
9 30702400 Linear Transducer L. 75 mm 21 100.6750300 Transparent safety guard
10 30201400 Plastification thermocouple 22 20101700 Clamp guard
11 20101600 Injection guard 23 30901200 Power supply 230VAC/24VDC - 240W
12 302.6702800 Plastification thermocouple

F-0180

You might also like