You are on page 1of 22

Inductive

Sensors Contents

Inductive sensors
with special mechanical
and/or electrical
properties.

Use under extremely


harsh conditions
Resistant to coolants
and lubricants
Use in welding
systems, magnetic
field-immune
Use in hydraulic
systems, high pressure
rated to 500 bar
Use in the foods and
chemicals industries,
1.5
stainless steel housing Multimetal/
Factor 1
Use in explosive
PROXINOX
atmospheres, NAMUR
PROXIMAX
to DIN EN 50227
Use in error monitoring, Diagnostics
self-diagnostic Pressure
rated
Use at high ambient
Temperature
temperatures up to
rated
+120 C
Weld-immune
NAMUR
1.5.2 Multimetal/Factor 1
Extended
Sensors with
Switching
no reduction factor Distance
1.5.4 PROXINOX-stainless Ring Sensors
steel sensors for the
foods industry
1.5.14 PROXIMAX-sensors
for especially harsh
conditions
1.5.17 Desina diagnostic
sensors for machine
tools, dynamic function
diagnostics
1.5.23 Pressure rated sensors
up to max. 500 bar
1.5.38 Temperature rated
sensors up to max.
+120 C
1.5.40 Weld- and magnetic

Multimetal/Factor 1 field-immune sensors


for welding environ-
ments
1.5.48 NAMUR sensors

diagnostics 1.5.54 Sensors with large


housings and extended
switching distance

pressure rated 1.5.62 Ring sensors

high pressure rated


magnetic field-immune PROXINOX
weld-immune
temperature rated PROXIMAX
Extended Switching Distance NAMUR
1.5.1
DC 3-Wire
Inductive M18
Sensors sn 5 mm, 12 mm
Housing size M181 M181
Mounting flush non-flush
Rated operating distance sn 5 mm 12 mm
Assured operating distance sa 0...4.1 mm 0...9.7 mm
Multimetal/Factor 1
sensors with no reduction
factor, consistent
switching distance with
all metals

The switching distance


remains the same for all
metals, with the reduction
factor always 1 sn, so that
only one switch model is
required for use with different
target compositions.

All sensors in the Multi- switching distance


metal/Factor 1 series are magnetic field immune magnetic field immune
magnetic field immune.
They are unaffected by the
PNP Normally-open 1 BES M18EL-PSH50A-S04G BES M18EL-PSH12E-S04G
presence of strong electro- Complementary 3
magnetic fields. This is
accomplished through the
NPN Normally-open 4# BES M18EL-NSH50A-S04G
use of special electronics. Complementary 6
Strong electromagnetic Rated operational voltage Ue 24 V DC 24 V DC
fields occur for exmaple Supply voltage UB 10...55 V DC 10...55 V DC
in induction hardening or Voltage drop Ud at le 2.5 V 2.5 V

welding systems. Rated insulation voltage Ui 250 V AC 250 V AC


Rated operational current Ie 200 mA 200 mA
No-load supply current I0 max. 17 mA 17 mA

Off-state current Ir 80 A 80 A

Protected against polarity reversal yes yes


Short circuit protected yes yes
Load capacity 1 F 1 F

Repeat accuracy R 5 % 5 %

Ambient temperature range Ta 25...+70 C 25...+70 C


Frequency of operating cycles f 600 Hz 300 Hz
Utilization categories DC 13 DC 13
Function indication yes/no yes/no

Degree of protection per IEC 60529 IP 67 IP 67


Insulation class [ [
Housing material stainless steel stainless steel
Material of sensing face LCP LCP
Connection connector connector

Recommended connector BKS-B 19/BKS-B 20 BKS-B 19/BKS-B 20


Mounting variations allowed

1 Wiring diagrams see page 1.0.12


Switching distance see page 1.0.3

Multimetal/Factor 1 is also available in


weld-immune versions, see pages 1.5.44
and 1.5.45.

1.5.2
DC 4-Wire
Inductive Quadraform Housings
Multimetal/Factor 1 Sensors sn 15 mm, 25 mm, 35 mm
404073 Unicompact 404073 Unicompact 404073 Unicompact 404073 Unicompact 404073 Unicompact
flush non-flush flush non-flush non-flush
15 mm 25 mm 15 mm 25 mm 35 mm
0...12.2 mm 0...20.3 mm 0...12.2 mm 0...20.3 mm 0...28.4 mm

magnetic field immune magnetic field immune 1.5


Multimetal/
Factor 1
BES Q40KEU-PAH15A-S04G-001 BES Q40KEU-PAH25E-S04G-001 BES Q40KEU-PAH15A-S04G BES Q40KEU-PAH25E-S04G BES Q40KEU-PAH35E-S04G
PROXINOX
PROXIMAX

BES Q40KEU-NAH15A-S04G-001 BES Q40KEU-NAH15A-S04G Diagnostics


Pressure
rated
24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
Temperature
10...55 V DC 10...55 V DC 10...55 V DC 10...55 V DC 10...55 V DC
rated
2.5 V 2.5 V 2.5 V 2.5 V 2.5 V
Weld-immune
75 V DC 75 V DC 75 V DC 75 V DC 75 V DC
NAMUR
200 mA 200 mA 200 mA 200 mA 200 mA
Extended
25 mA 25 mA 25 mA 25 mA 25 mA
Switching
80 A 80 A 80 A 80 A 80 A
Distance
yes yes yes yes yes Ring Sensors
yes yes yes yes yes
1 F 1 F 1 F 1 F 1 F

5 % 5 % 5 % 5 % 5 %

25...+70 C 25...+70 C 25...+70 C 25...+70 C 25...+70 C


400 Hz 400 Hz 400 Hz 400 Hz 300 Hz
DC 13 DC 13 DC 13 DC 13 DC 13
yes/yes yes/yes yes/yes yes/yes yes/yes

IP 67 IP 67 IP 67 IP 67 IP 67

PBT/GD-ZnAl PBT/GD-ZnAl PBT/GD-ZnAl PBT/GD-ZnAl PBT/GD-ZnAl


PBT PBT PBT PBT PBT
connector connector connector connector connector

BKS-B 19/BKS-B 20 BKS-B 19/BKS-B 20 BKS-B 19/BKS-B 20 BKS-B 19/BKS-B 20 BKS-B 19/BKS-B 20
Figs. 1 to 6 Figs. 3 to 6 Figs. 1 to 6 Figs. 3 to 6 Figs. 4 and 6

Row mounting
flush 80 mm
non-flush 120 mm
6
Connectors,
clamps ...
page 6.2 ...

Mounting variations

Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 1.5.3


DC 3-Wire
Inductive M12
Sensors sn 2 mm
Housing size M121
Mounting flush
Rated operating distance sn 2 mm
Assured operating distance sa 0...1.6 mm
Built to take it stainless
steel housings leave
aggressive media cold.

Inductive proximity switches


are used increasingly in
places where harsh environ-
mental conditions prevail.

This is true not only in the


machine tool area, but
especially in the chemical
industry, packaging
machines, and the food
steel
industry. The main criteria stainless extended
are resistance to aggressive 1.4 1
5 7 temperature range
cleaning fluids often together
with high pressure cleaning PNP Normally-open 1 BES 515-325-S 4-C
equipment.
Rated operational voltage Ue 24 V DC
The solution = PROXINOX Supply voltage UB 10...30 V DC
Voltage drop Ud at le 1.5 V

Rated insulation voltage Ui 250 V AC


Rated operational current Ie 200 mA
No-load supply current I0 max. 8 mA

Off-state current Ir 50 A

Protected against polarity reversal yes


Short circuit protected yes
Load capacity 0.5 F

Repeat accuracy R 5 %

Ambient temperature range Ta 40...+85 C


Frequency of operating cycles f 3000 Hz

Utilization categories DC 13
Function indication yes

Degree of protection per IEC 60529 IP 68 per BWN Pr. 20


Insulation class [
Housing material stainless steel
Material of sensing face PA 12
Connection connector
No. of wires conductor cross section
Approval cULus
Recommended connector BKS-B 20E

1 Wiring diagrams see page 1.0.12


Please add the cable length to the ordering
code for sensors with cable!
03, 05 = PVC, length 3 m or 5 m
PU-03, PU-05 = PUR, length 3 m or 5 m

1.5.4
DC 3-Wire
Inductive M12
PROXINOXStandard DC Sensors sn 2 mm, 4 mm
M121 M121 M121 M121
flush non-flush non-flush non-flush
2 mm 4 mm 4 mm 4 mm
0...1.6 mm 0...3.2 mm 0...3.2 mm 0...3.2 mm

extended
temperature range
extended
temperature range
extended
temperature range 1.5
BES 515-325-B0-C- BES 515-356-S 4-C BES 515-356-B0-C- BES 515-356-E4-Y- Multimetal/
Factor 1
PROXINOX
24 V DC 24 V DC 24 V DC 24 V DC
PROXIMAX
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
1.5 V 1.5 V 1.5 V 3.5 V
Diagnostics
250 V AC 250 V AC 250 V AC 75 V DC Pressure
rated
200 mA 200 mA 200 mA 130 mA
Temperature
8 mA 8 mA 8 mA 25 mA
rated
50 A 50 A 50 A 80 A
Weld-immune
yes yes yes yes
NAMUR
yes yes yes yes
Extended
0.5 F 0.5 F 0.5 F 1 F
Switching
Distance
5 % 5 % 5 % 5 %
Ring Sensors
40...+85 C 40...+85 C 40...+85 C 25...+70 C
3000 Hz 1500 Hz 1500 Hz 400 Hz

DC 13 DC 13 DC 13 DC 13
yes yes yes yes

IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20
[ [ [
stainless steel stainless steel stainless steel stainless steel
PA 12 PA 12 PA 12 PA 12
cable connector cable cable
3 0.34 mm 3 0.34 mm 3 0.34 mm
cULus cULus cULus cULus
BKS-B 20E

6
Connectors,
clamps ...
page 6.2 ...

1.5.5
DC 3-/4-Wire
Inductive M18
Sensors sn 5 mm, 8 mm
Housing size M181 M181 M181 M181
Mounting flush flush non-flush non-flush
Rated operating distance sn 5 mm 5 mm 8 mm 8 mm
Assured operating distance sa 0...4.1 mm 0...4.1 mm 0...6.5 mm 0...6.5 mm

steel
stainless
1.4 1
5 7

PNP Normally-open 1 BES 515-326-S 4-C BES 515-326-B0-C- BES 515-360-S 4-C BES 515-360-B0-C-
Complementary 3 BES 515-123-S 4-C

Rated operational voltage Ue 24 V DC 24 V DC 24 V DC 24 V DC


Supply voltage UB 10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
Voltage drop Ud at le 1.5 V 1.5 V 1.5 V 1.5 V

Rated insulation voltage Ui 250 V AC 250 V AC 250 V AC 250 V AC


Rated operational current Ie 200 mA 200 mA 200 mA 200 mA
No-load supply current I0 max. 25 mA 25 mA 25 mA 25 mA

Off-state current Ir 80 A 80 A 80 A 80 A

Protected against polarity reversal yes yes yes yes


Short circuit protected yes yes yes yes
Load capacity 1 F 1 F 1 F 1 F

Repeat accuracy R 5 % 5 % 5 % 5 %

Ambient temperature range Ta 25...+70 C 25...+70 C 25...+70 C 25...+70 C


Frequency of operating cycles f 900 Hz 900 Hz 600 Hz 600 Hz
Utilization categories DC 13 DC 13 DC 13 DC 13
Function indication yes yes yes yes

Degree of protection per IEC 60529 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20
Insulation class [ [ [ [
Housing material stainless steel stainless steel stainless steel stainless steel
Material of sensing face PA 12 PA 12 PA 12 PA 12
Connection connector cable connector cable
No. of wires conductor cross section 3 0.34 mm 3 0.34 mm
Approval cULus cULus cULus cULus
Recommended connector BKS-B 20E BKS-B 20E

1 Wiring diagrams see page 1.0.12


Please add the cable length to the ordering
code for sensors with cable!
03, 05 = PVC, length 3 m or 5 m
PU-03, PU-05 = PUR, length 3 m or 5 m

1.5.6
DC 3-Wire
Inductive M30
PROXINOXStandard DC Sensors sn 10 mm, 15 mm
M301.5 M301.5 M301.5
flush flush non-flush
10 mm 10 mm 15 mm
0...8.1 mm 0...8.1 mm 0...12.2 mm

1.5
BES 515-327-S 4-C BES 515-327-B0-C- BES 515-362-S 4-C Multimetal/
Factor 1
PROXINOX
PROXIMAX
24 V DC 24 V DC 24 V DC
10...30 V DC 10...30 V DC 10...30 V DC Diagnostics
2.5 V 2.5 V 2.5 V
Pressure
rated
250 V AC 250 V AC 250 V AC
Temperature
200 mA 200 mA 200 mA
rated
25 mA 25 mA 25 mA
Weld-immune
80 A 80 A 80 A
NAMUR
yes yes yes
Extended
yes yes yes
Switching
1 F 1 F 1 F
Distance
Ring Sensors
5% 5% 5%
25...+70 C 25...+70 C 25...+70 C
300 Hz 300 Hz 100 Hz

DC 13 DC 13 DC 13
yes yes yes

IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20


[ [ [
stainless steel stainless steel stainless steel
PA 12 PA 12 PA 12
connector cable connector
3 0.34 mm
cULus cULus
BKS-B 20E BKS-B 20E

6
Connectors,
clamps ...
page 6.2 ...

1.5.7
Inductive PROXINOX-
Sensors Stainless Steel Sensors
Housing size
Mounting
Rated operating distance sn
Assured operating distance sa
PROXINOX-sensors Gold contacts:
withstands the harshest harsh conditions demand
cleaning processes gold plated contacts in
order to avoid connector
In the food and beverage corrosion.
industry, the chemical Laser etched part number:
industry, and even conveying cleaning agents and
operations, inductive disinfectants can remove
proximity sensors are a label. Etched part
routinely cleaned with numbers are there to stay.
more and more aggressive Additional O-ring seals:
agents. Whether it's acids, temperature shock,
base, steam, foam or high caused by cleaning and
pressure cleaning equipment disinfection, lead
steel
the technology in the new to strongly different stainless
PROXINOX-stainless steel expansions of a steel 1.4 1
5 7
sensors is especially housing and the internal
designed for these harsh epoxy. These extreme PNP Normally-open 1
conditions. effects are eliminated by
our elastic O-ring seals. Rated operational voltage Ue
Insulation cups and Supply voltage UB
Features insulation sleeves ensure Voltage drop Ud at le
maximum insulation. Rated insulation voltage Ui
No function display Rated operational current Ie
directly on sensor: No-load supply current I0 max.
the hole for the LED is a Off-state current Ir
potential source of danger Protected against polarity reversal
when cleaning, as well Short circuit protected
as a possible entry for Load capacity
bacteria. The function
display is completely Repeat accuracy R
wrapped in the transpa- Ambient temperature range Ta
rent plastic of the Frequency of operating cycles f
connector. Utilization categories
Housing of stainless steel: Function indication
type 1.4571 stainless
steel is what the food and Degree of protection per IEC 60529
beverage industry
demands. The connector
plug must also be capable Housing material
of withstanding cleaning Material of sensing face
and disinfecting agents. Connection

Approval
Recommended connector

1 Wiring diagrams see page 1.0.12

stainless steel Current reduction as a function


1.4571 of ambient temperature

130 mA

gold laser etched part number,


contacts manufacturer and
manufacturing date
30 mA

O-ring seals inside


the connector
40 C +70 C +105 C

function LED in connector

1.5.8
DC 3-Wire
Inductive M12
PROXINOX Requirements
Extended
DC Sensors sn 2 mm, 4 mm
M121 M121 M121 M121
flush flush non-flush non-flush
2 mm 2 mm 4 mm 4 mm
0...1.6 mm 0...1.6 mm 0...3.2 mm 0...3.2 mm

1.5
BES 515-325-SA 61-S 4-T BES 515-325-E5-T-S 4 BES 515-356-SA 27-S 4-T BES 515-356-E5-T-S 4 Multimetal/
Factor 1
PROXINOX
24 V DC 24 V DC 24 V DC 24 V DC
PROXIMAX
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
3.5 V 3.5 V 3.5 V 3.5 V
Diagnostics
75 V AC 75 V DC 75 V AC 75 V DC Pressure
rated
130 mA 130 mA 130 mA 130 mA
Temperature
25 mA 25 mA 25 mA 25 mA
rated
80 A 80 A 80 A 80 A
Weld-immune
yes yes yes yes
NAMUR
yes yes yes yes
Extended
1 F 1 F 1 F 1 F
Switching
Distance
5 % 5 % 5 % 5 %
Ring Sensors
40...+105 C 40...+105 C 40...+105 C 40...+105 C
800 Hz 800 Hz 400 Hz 400 Hz
DC 13 DC 13 DC 13 DC 13

no no no no

IP 69K and IP 69K and IP 69K and IP 69K and


IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27

stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571
PEEK PEEK PEEK PEEK
connector connector connector connector

cULus cULus cULus cULus


BKS-B 20E BKS-B 20E BKS-B 20E BKS-B 20E

6
Connectors,
clamps ...
page 6.2 ...

1.5.9
DC 3-Wire
Inductive M18
Sensors sn 5 mm, 8 mm
Housing size M181 M181 M181 M181
Mounting flush flush non-flush non-flush
Rated operating distance sn 5 mm 5 mm 8 mm 8 mm
Assured operating distance sa 0...4.1 mm 0...4.1 mm 0...6.5 mm 0...6.5 mm

steel
stainless
1.4 1
5 7

PNP Normally-open 1 BES 515-326-SA 46-S 4-T BES 515-326-E5-T-S 4 BES 515-360-SA 12-S 4-T BES 515-360-E5-T-S 4

Rated operational voltage Ue 24 V DC 24 V DC 24 V AC 24 V DC


Supply voltage UB 10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
Voltage drop Ud at le 3.5 V 3.5 V 3.5 V 3.5 V

Rated insulation voltage Ui 75 V DC 75 V DC 75 V DC 75 V DC


Rated operational current Ie 130 mA 130 mA 130 mA 130 mA
No-load supply current I0 max. 25 mA 25 mA 25 mA 25 mA

Off-state current Ir 80 A 80 A 80 A 80 A

Protected against polarity reversal yes yes yes yes


Short circuit protected yes yes yes yes
Load capacity 1 F 1 F 1 F 1 F

Repeat accuracy R 5 % 5 % 5 % 5 %

Ambient temperature range Ta 40...+105 C 40...+105 C 40...+105 C 40...+105 C


Frequency of operating cycles f 500 Hz 500 Hz 200 Hz 200 Hz
Utilization categories DC 13 DC 13 DC 13 DC 13
Function indication no no no no

Degree of protection per IEC 60529 IP 69K and IP 69K and IP 69K and IP 69K and
IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27

Housing material stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571
Material of sensing face PA 12 PA 12 PA 12 PA 12
Connection connector connector connector connector

Approval cULus cULus cULus cULus


Recommended connector BKS-B 20E BKS-B 20E BKS-B 20E BKS-B 20E

1 Wiring diagrams see page 1.0.12

Current reduction as a function


of ambient temperature

130 mA

30 mA

40 C +70 C +105 C

1.5.10
DC 3-Wire
Inductive M30, 20 mm
PROXINOX Requirements
Extended
DC Sensors sn 10 mm, 15 mm
M301.5 M301.5 M301.5 2080 2060

flush flush non-flush non-flush non-flush


10 mm 10 mm 15 mm 10 mm 10 mm
0...8.1 mm 0...8.1 mm 0...12.2 mm 0...8.1 mm 0...8.1 mm

1.5
BES 515-327-SA 20-S 4-T BES 515-327-E5-T-S 4 BES 515-362-SA 3-S 4-T BES G20ES-PSD10F-S4G-T501 BES G20ES-PSD10F-S4G-T502 Multimetal/
Factor 1
PROXINOX
24 V DC 24 V DC 24 V DC 24 V DC 24 V DC
PROXIMAX
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
3.5 V 3.5 V 3.5 V 3.5 V 3.5 V
Diagnostics
75 V DC 75 V DC 75 V DC 75 V DC 75 V DC Pressure
rated
130 mA 130 mA 130 mA 130 mA 130 mA
Temperature
20 mA 20 mA 20 mA 12 mA 12 mA
rated
80 A 80 A 80 A 80 A 80 A
Weld-immune
yes yes yes yes yes
NAMUR
yes yes yes yes yes
Extended
1 F 1 F 1 F 1 F 1 F
Switching
Distance
5 % 5 % 5 % 5 % 5 %
Ring Sensors
40...+105 C 40...+105 C 40...+105 C 40...+105 C 40...+105 C
200 Hz 200 Hz 100 Hz 300 Hz 300 Hz
DC 13 DC 13 DC 13 DC 13 DC 13
no no no no no

IP 69K and IP 69K and IP 69K and IP 69K and IP 69K and
IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27 IP 68 per BWN Pr. 27

stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571 stainless steel 1.4571
PA 12 PA 12 PA 12 PA 12 PA 12
connector connector connector connector connector

cULus
BKS-B 20E BKS-B 20E BKS-B 20E BKS-B 20E BKS-B 20E

6
Connectors,
clamps ...
page 6.2 ...

1.5.11
AC/DC 2-Wire
Inductive M12
Sensors sn 2 mm, 4 mm
Housing size M121 M121 M121
Mounting flush flush non-flush
Rated operating distance sn 2 mm 2 mm 4 mm
Assured operating distance sa 0...1.6 mm 0...1.6 mm 0...3.2 mm

steel
stainless
1.4 1
5 7

AC/DC Normally-open % / BES 515-207-S 5-E BES 515-207-S 21-E BES 515-209-S 21-E
Normally-closed & ( BES 515-208-S 21-E BES 515-210-S 21-E

Rated operational voltage Ue 110 V AC 110 V AC 110 V AC


Supply voltage UB 20...250 V AC/DC 20...250 V AC/DC 20...250 V AC/DC
Voltage drop Ud at le 11 V/ 7.5 V dyn. 11 V/ 7.5 V dyn. 11 V/ 7.5 V dyn.

Rated insulation voltage Ui 250 V AC 250 V AC 250 V AC


Rated operational current Ie 130 mA 130 mA 130 mA
Minimum operational current Im 5 mA 5 mA 5 mA
Off-state current Ir 1.7 mA at 110 V AC 1.7 mA at 110 V AC 1.7 mA at 110 V AC

Inrush current Ik t 20 ms 0.7 A/ 0.5 Hz 1 A/ 0.5 Hz 1 A/ 0.5 Hz

Protected against polarity reversal yes yes yes


Short circuit protected/overload protected yes/yes yes/yes yes/yes

Repeat accuracy R 5 % 5 % 5 %

Ambient temperature range Ta 25...+70 C 25...+70 C 25...+70 C


Frequency of operating cycles f 1000 Hz 1000 Hz 600 Hz
Utilization categories AC 140/DC 13 AC 140/DC 13 AC 140/DC 13
Function indication yes yes yes

Degree of protection per IEC 60529 IP 67 IP 67 IP 67


Insulation class with protection GND with protection GND with protection GND
Housing material stainless steel stainless steel stainless steel
Material of sensing face PA 12 PA 12 PA 12
Connection connector connector connector

Approval cULus cULus cULus


Recommended connector BKS-S 5-AC BKS-S 21/BKS-S 22 BKS-S 21/BKS-S 22

% Wiring diagrams see page 1.0.12

1.5.12
AC/DC 2-Wire
Inductive M18, M30
PROXINOXStandard AC/DC Sensors sn 5, 8, 10, 15 mm
M181 M181 M301.5 M301.5
flush non-flush flush non-flush
5 mm 8 mm 10 mm 15 mm
0...4.1 mm 0...6.5 mm 0...8.1 mm 0...12.2 mm

1.5
BES 515-211-E5-E-S 21 BES 515-213-E5-E-S 21 BES 515-215-E5-E-S 21 BES 515-217-E5-E-S 21 Multimetal/
Factor 1
PROXINOX
PROXIMAX
110 V AC 110 V AC 110 V AC 110 V AC
20...250 V AC/DC 20...250 V AC/DC 20...250 V AC/DC 20...250 V AC/DC Diagnostics
11 V/ 7.5 V dyn. 11 V/ 7.5 V dyn. 11 V/ 7.5 V dyn. 11 V/ 7.5 V dyn.
Pressure
rated
250 V AC 250 V AC 250 V AC 250 V AC
Temperature
250 mA 250 mA 250 mA 250 mA
rated
5 mA 5 mA 5 mA 5 mA
Weld-immune
1.7 mA at 110 V AC 1.7 mA at 110 V AC 1.7 mA at 110 V AC 1.7 mA at 110 V AC
NAMUR
2 A/ 1 Hz 2 A/ 1 Hz 2 A/ 1 Hz 2 A/ 1 Hz
Extended
yes yes yes yes
Switching
yes/yes yes/yes yes/yes yes/yes Distance
Ring Sensors
5% 5% 10 % 10 %
25...+70 C 25...+70 C 25...+70 C 25...+70 C
400 Hz 250 Hz 150 Hz 100 Hz
AC 140/DC 13 AC 140/DC 13 AC 140/DC 13 AC 140/DC 13
yes yes yes yes

IP 67 IP 67 IP 67 IP 67
with protection GND with protection GND with protection GND with protection GND
stainless steel stainless steel stainless steel stainless steel
PA 12 PA 12 PA 12 PA 12
connector connector connector connector

cULus cULus cULus cULus


BKS-S 21/BKS-S 22 BKS-S 21/BKS-S 22 BKS-S 21/BKS-S 22 BKS-S 21/BKS-S 22
Also available with Also available with Also available with Also available with
metric M121 metric M121 metric M121 metric M121
connector thread. connector thread. connector thread. connector thread.
Ordering code: Ordering code: Ordering code: Ordering code:
BES 515-211-E5-E-S 27 BES 515-213-E5-E-S 27 BES 515-215-E5-E-S 27 BES 515-217-E5-E-S 27

6
Connectors,
clamps ...
page 6.2 ...

1.5.13
Inductive
Sensors PROXIMAX-Sensors
Housing size
Mounting
Rated operating distance sn
Assured operating distance sa

PROXIMAX The housing is made of


a sensor concept for chemical-resistant, rust-free
machine tools stainless steel 1.4305, so
that together with the other
Sensors are subjected properties, the entire switch Normally-open 1
to extreme stresses on a has a high resistance to
PNP Normally-closed 2
machine tool. most of the coolants and
lubricants found on machine NPN Normally-open 4#
This has led to the design tools. The sensors is rated
of the PROXIMAX concept IP 68. Rated operational voltage Ue
for inductive proximity Supply voltage UB
switches. Mechanical All models come standard Voltage drop Ud at le
resistance was given special with extended sensing Rated insulation voltage Ui
attention in this design. range. They are fully flush Rated operational current Ie
As opposed to traditional mountable, and do not No-load supply current I0 max.
approaches, the front require any clear zone as is Off-state current Ir
section of the switch is the case with most sensors Protected against polarity reversal
molded with Duromer. All the having extended range. Short circuit protected
important components are This means less time spent Load capacity
housed in this section, the adjusting at often inacces-
sensor oscillator circuit and sible spots on the machine Repeat accuracy R
the bonded IC. The cavity- tool, so the machine is up Ambient temperature range Ta
free material surrounds the and running just that much Frequency of operating cycles f
electronic parts and makes sooner. Utilization categories
the switch insensitive to Function indication
shock and vibration.
Degree of protection per IEC 60529
The mineral-filled and Insulation class
fiber- glass reinforced epoxy Housing material
potting is also extremely Material of sensing face
resistant to chemicals, Connection
abrasion resistant, and No. of wires conductor cross section
can withstand continuous Approval
temperatures. Such a Recommended connector
molded proximity switch can
even withstand the flame of Pressure rated up to
a blowtorch for a short time.
This guarantees that it will 1 Wiring diagrams see page 1.0.12
hold up against any kind of Switching distance see page 1.0.3
hot chips, even if they stick
to the active surface. Please add the cable length to the ordering
code for sensors with cable!
BP03, BP05 = PUR, length 3 m or 5 m

The Duromer molded


front section is extremely
temperature resistant to
hot chips.
The stainless housing is
extremely rugged.

1.5.14
DC 3-Wire
Inductive M12, M18
PROXIMAX Sensors sn 4 mm, 8 mm
M121 M121 M181 M181
flush flush flush flush
4 mm 4 mm 8 mm 8 mm
0...3.2 mm 0...3.2 mm 0...6.5 mm 0...6.5 mm

extended extended extended extended


temperature range
switching distance
temperature range
switching distance
temperature range
switching distance
temperature range
switching distance 1.5
BES M12EL-PSC40B-S04G BES M12EL-PSC40B- BES M18EL-PSC80B-S04G BES M18EL-PSC80B- Multimetal/
Factor 1
BES M12EL-POC40B-S04G BES M18EL-POC80B-S04G
PROXINOX
PROXIMAX
BES M12EL-NSC40B-S04G BES M18EL-NSC80B-S04G
Diagnostics
24 V DC 24 V DC 24 V DC 24 V DC Pressure
rated
10...30 V DC 10...30 V DC 10...30 V DC 10...30 V DC
Temperature
1.8 V 1.8 V 1.8 V 1.8 V
rated
250 V AC 250 V AC 250 V AC 250 V AC
Weld-immune
200 mA 200 mA 200 mA 200 mA
NAMUR
8 mA 8 mA 8 mA 8 mA
Extended
10 A 10 A 10 A 10 A
Switching
yes yes yes yes Distance
yes yes yes yes Ring Sensors
1 F 1 F 1 F 1 F

5 % 5 % 5 % 5 %

40...+105 C 40...+85 C 40...+105 C 40...+85 C


1000 Hz 1000 Hz 700 Hz 700 Hz
DC 13 DC 13 DC 13 DC 13
yes yes yes yes

IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20
[ [ [ [
stainless steel stainless steel stainless steel stainless steel
EP (Duromer) EP (Duromer) EP (Duromer) EP (Duromer)
connector cable connector cable
3 0.34 mm 3 0.34 mm
cULus cULus cULus cULus
BKS-S 23/BKS-S 24 BKS-S 23/BKS-S 24

60 bar 60 bar 60 bar 60 bar

6
Connectors,
clamps ...
page 6.2 ...

1.5.15
AC/DC 2-Wire
Inductive M12, M18
Sensors sn 4 mm, 8 mm PROXIMAX
Housing size M121 M121 M181 M181
Mounting flush flush flush flush
Rated operating distance sn 4 mm 4 mm 8 mm 8 mm
Assured operating distance sa 0...3.2 mm 0...3.2 mm 0...6.5 mm 0...6.5 mm

switching distance switching distance switching distance switching distance

AC/DC Normally-open / BES M12EL-USV40B-S21G- BES M12EI2-USV40B-S05G- BES M18EI1-UST80B-S21G- BES M18EI2-UST80B-S05G-

Rated operational voltage Ue 110 V AC 110 V AC 110 V AC 110 V AC


Supply voltage UB 20...140 V AC/DC 20...140 V AC/DC 20...250 V AC/DC 20...250 V AC/DC
Voltage drop Ud at le 5 V 5 V 5.5 V 5.5 V

Rated insulation voltage Ui 250 V AC 250 V AC 250 V AC 250 V AC


Rated operational current Ie 200 mA 200 mA 350 mA 350 mA
Minimum operational current Im 5 mA 5 mA 5 mA 5 mA
Off-state current Ir 0.8 mA 0.8 mA 0.8 mA 0,8 mA

Inrush current Ik t 20 ms 2 A/ 1 Hz 2 A/ 1 Hz 2,2 A/ 1 Hz 2,2 A/ 1 Hz

Protected against polarity reversal yes yes yes yes


Short circuit protected/overload protected no/no no/no no/no no/no

Repeat accuracy R 5 % 5 % 5 % 5 %

Ambient temperature range Ta 25...+70 C 25...+70 C 25...+70 C 25...+70 C


Frequency of operating cycles f 1000 Hz 1000 Hz 400 Hz 400 Hz
Utilization categories AC 140/DC 13 AC 140/DC 13 AC 140/DC 13 AC 140/DC 13
Function indication yes yes yes yes

Degree of protection per IEC 60529 IP 67 IP 67 IP 67 IP 67


Insulation class with protection GND with protection GND with protection GND with protection GND
Housing material stainless steel stainless steel stainless steel stainless steel
Material of sensing face EP (Duromer) EP (Duromer) EP (Duromer) EP (Duromer)
Connection connector connector connector connector

Recommended connector BKS-S 21/BKS-S 22 BKS-S 5-AC BKS-S 21/BKS-S 22 BKS-S 5-AC

/ Wiring diagrams see page 1.0.12


Switching distance see page 1.0.3

Please add the version to the ordering code!


004 = LED red
505 = LED red, housing also PTFE coated

PROXIMAX-sensor in 2-wire version with


additional diagnostic output see page 1.5.17.

1.5.16
DC 2-Wire
Inductive M12
diagnostics Sensors sn 2 mm, 4 mm
Housing size M121 M121
Mounting flush flush
Rated operating distance sn 2 mm 4 mm
Assured operating distance sa 0...1.6 mm 0...3.2 mm
Desina sensor
in 2-wire version
with setup aid and
diagnostic output

This inductive proximity


switch has been specially
developed to the Desina
specification for the harsh
environment of a machine
tool.

The Duromer encased front


section makes the switch
extended
resistant to shock, vibration
and hot chips. The stainless
steel housing together
extended
temperature range
temperature range
switching distance 1.5
Multimetal/
with the Duromer coating PNP Normally-open BES M12EL-GSH20B-S04G-M01 BES M12EL-GSH40B-S04G-M01
Factor 1
provides very high resistance
PROXINOX
to aggressive coolants and Rated operational voltage Ue 24 V DC 24 V DC
PROXIMAX
lubricants. Supply voltage UB 10...55 V DC 10...55 V DC
Voltage drop Ud at le 3.7 V 3.7 V
Diagnostics
Based on the PROXIMAX Rated insulation voltage Ui 250 V AC 250 V AC Pressure
rated
concept with all its benefits, Rated operational current Ie 200 mA 200 mA
Temperature
this switch meets all Desina Minimum operational current Im 3 mA 3 mA
rated
specifications. Off-state current Ir 0.65 mA 0.65 mA
Weld-immune
Protected against polarity reversal yes yes
NAMUR
These sensors provide all Short circuit protected yes yes
Extended
the advantages of Load capacity 0.2 F 0.2 F
Switching
PROXIMAX technology, Distance
including: Repeat accuracy R 5 % 5 %
Ring Sensors
Duromer coated front Ambient temperature range Ta 40...+105 C 40...+105 C
section Frequency of operating cycles f 3000 Hz 1000 Hz
Degree of protection IP 68 Utilization categories DC 13 DC 13
Stainless steel housing Function indication yes yes

The additional diagnostic Degree of protection per IEC 60529 IP 68 per BWN Pr. 20 IP 68 per BWN Pr. 20
output monitors the Insulation class [ [
function of the switch and Housing material stainless steel stainless steel
the supply line. When Material of sensing face EP (Duromer) EP (Duromer)
the sensor is functioning Connection connector connector
properly the diagnostic
output is conducting.
Electrical data: diagnostic Recommended connector BKS-S 23/BKS-S 24 BKS-S 23/BKS-S 24
output Imax 50 mA.
Pressure rated up to 60 bar 60 bar
An optical setup aid
simplifies proper adjustment. Switching distance see page 1.0.12
This ensures that the sensor
operates reliably over the Wiring diagram
entire tolerance range.
sensor

monitor
Note!

Connectors with integrated The Desina sensor can 6


Connectors,
LED function display should also be connected to an
clamps ...
not be used with function AS-Interface through a user
page 6.2 ...
diagnostics switches. This is module with static diagnostics
because the LED is in paral- BAS S-010-S0-P0-S 4 (page
lel with the load RL, thus 5.11).
defeating the cable break Static diagnostics refers to an
monitoring function. additional signal that verifies
sensor function by the
presence of this signal.

1.5.17
DC 3-Wire
Inductive M12
Sensors sn 2 mm diagnostics
Housing size M121
Mounting flush
Rated operating distance sn 2 mm
Assured operating distance sa 0...1.6 mm
Desina sensor
in 3-wire version
with setup aid and
diagnostic output

This inductive proximity


switch has been specially
developed to the Desina
specification for the harsh
environment of a machine
tool.

The additional diagnostic


output monitors the
function of the switch and
the supply line. As long as
the sensor is functioning,
a high-signal is present on PNP Normally-open BES M12EL-PSC20B-S04G-M01
the output.
Rated operational voltage Ue 24 V DC
The optical setup aid Supply voltage UB 10...30 V DC
guarantees optimal working Voltage drop Ud at le 3.5 V

distance. This ensures Rated insulation voltage Ui 75 V DC


that the sensor operates Rated operational current Ie 200 mA
reliably over the entire Minimum operational current Im 3 mA
tolerance range. The range No-load supply current I0 max. 8 mA

from sn to sa is indicated by Off-state current Ir 80 A

a flashing LED. Protected against polarity reversal yes


Short circuit protected yes
Load capacity 0.5 F

Note!
Repeat accuracy R 5 %

Connectors with integrated Ambient temperature range Ta 25...+70 C


LED function display should Frequency of operating cycles f 800 Hz
not be used with function Utilization categories DC 13
diagnostics switches. This is Function indication yes
because the LED is in paral-
lel with the load RL, thus Degree of protection per IEC 60529 IP 68 per BWN Pr. 20
defeating the cable break
monitoring function. Housing material stainless steel
Material of sensing face LCP
Connection connector

Recommended connector BKS-B 19-3-_Y/BKS-B 20-3-_Y

Wiring diagram

sensor
monitor

The Desina sensor can


also be connected to an
AS-Interface through a user
module with static diagnostics
BAS S-010-S0-P0-S 4 (page
5.11).
Static diagnostics refers to an
additional signal that verifies
sensor function by the
presence of this signal.

1.5.18
DC 3-Wire
Inductive M12
diagnostics
+ high pressure rated
Sensors sn 1.5 mm
Housing size M121
Mounting flush
Rated operating distance sn 1.5 mm
Assured operating distance sa 0...1.2 mm

1.5
Multimetal/
PNP Normally-open BES M12EL-PSC15B-S04G-HM01
Factor 1
PROXINOX
Inductive sensor Rated operational voltage Ue 24 V DC
PROXIMAX
high pressure rated up to Supply voltage UB 10...30 V DC
500 bar, with diagnostics Voltage drop Ud at le 3.7 V
Diagnostics
and setup aid. Rated insulation voltage Ui 75 V DC Pressure
rated
Rated operational current Ie 200 mA
Temperature
High-pressure rated The optical setup aid Minimum operational current Im 3 mA
rated
inductive proximity switches guarantees optimal working No-load supply current I0 max. 10 mA
Weld-immune
are used for sensing the distance. This ensures Off-state current Ir 80 A
NAMUR
piston position in hydraulic that the sensor operates Protected against polarity reversal yes
Extended
cylinders. reliably over the entire Short circuit protected yes
Switching
tolerance range. Flashing Load capacity 0.5 F
Distance
In such applications the LED's indicate marginal Ring Sensors
active surface of the switch range. Repeat accuracy R 5%
is subjected to high pressure Ambient temperature range Ta 25...+70 C
in the cylinder interior. Frequency of operating cycles f 300 Hz
Note! Utilization categories DC 13
Balluff employs a special Function indication yes
manufacturing technique Connectors with integrated
for making the active LED function display should Degree of protection per IEC 60529 IP 68 per BWN Pr. 20
surface able to withstand not be used with function
such conditions. The coils diagnostics switches. This is Housing material stainless steel
are molded in Duromer. because the LED is in paral- Material of sensing face EP
The additional diagnostic lel with the load RL, thus Connection connector
output monitors function of defeating the cable break
the switch and presence of monitoring function.
supply voltage. As long as Recommended connector BKS-B 19-3-_Y/BKS-B 20-3-_Y
the sensor is fully functional, O-ring/replacement part number 5.85 2.4/636594
a high-level signal is output. Support ring/replacement part number 10 5.9 1/705918

High pressure rated up to 500 bar

Wiring diagram

sensor
monitor
The Desina sensor can
also be connected to an 6
Connectors,
AS-Interface through a user
clamps ...
module with static diagnostics
page 6.2 ...
BAS S-010-S0-P0-S 4 (page
5.11).
Static diagnostics refers to an
additional signal that verifies
sensor function by the
presence of this signal.

1.5.19
Inductive Dynamic
Sensors Function Diagnostics

Function Faultless operation of the Function monitoring Installation


proximity switch is assured
Proximity switches with as long as the pulses are The "test pulses" and The signal lines to the
dynamic function diagnostics present. thereby the function of the function diagnostics unit
permit virtually complete proximity switch are should be kept as close
monitoring of all sensor The pulse frequency is monitored by an additional to the load RL as possible
functions including the cable. f ~ 160 Hz, and the pulse device which signals error- (see A). In the case of
duration t ~ 300 s. The free function with a high- connection point B, the
For this, a switched duty factor of t ~ 5 % is signal level on a "status/ section between B and
current source is used to small enough that the test output". load RL is not monitored.
momentarily electrically pulses can be blocked
damp and undamp the out by the input filter of a Balluff offers for it the
oscillator in opposite controller; alternately, following function diagnostics
phase with the magnetic direct switching of a relay units, which can be easily
damping state of the sensor is possible. The information integrated into a controller:
field and the oscillator "proximity switch proximity switch
signal is additionally modu- magnetically damped or BES 113-FD-1 with function
lated. During the electrical undamped" can therefore (for 1 sensor) diagnostics
damping, so-called "test be processed in the usual
pulses" are overlayed on manner. The following sensors can
the output signal. Depending be connected:
on the magnetic damping
condition, these pulses are BES 113-356-SA 6 monitors
positive or negative. normally-open, and

BES 113-3019-SA 1 Note!


normally-closed
damping travel
The system described
switching level Single faults are detectable here is not intended for
over the entire system. personal safety systems.

damped undamped damped For additional information


please request a user's
guide.
output signal

error
relay output

status output

Pulse diagram for a proximity switch with function diagnostics


(normally- closed).

1.5.20
DC 3-Wire
Inductive M12
diagnostics Sensors sn 3.7 mm
Housing size M121 M121
Mounting non-flush non-flush
Rated operating distance sn 3.7 mm 3.7 mm
Assured operating distance sa 0...3 mm 0...3 mm
Note!

Connectors with integrated


LED function display should
not be used with function
diagnostics switches. This is
because the LED is in paral-
lel with the load RL, thus
defeating the cable break
monitoring function.

Switch function can, how-


ever, be monitored from the
LED's on the monitor.

1.5
PNP Normally-open 1 BES 113-356-SA 6-S 4 BES 113-356-SA 6-PU- Multimetal/
Factor 1
Normally-closed 2 BES 113-3019-SA 1-S 4 BES 113-3019-SA 1-PU-
PROXINOX
PROXIMAX
Rated operational voltage Ue 24 V DC 24 V DC
Supply voltage UB 20...30 V DC 20...30 V DC Diagnostics
Voltage drop Ud at le typ. 2.5 V typ. 2.5 V Pressure
rated
Rated insulation voltage Ui 75 V DC 75 V DC
Temperature
Rated operational current Ie 130 mA 130 mA
rated
Minimum operational current Im 1 mA 1 mA
Weld-immune
No-load supply current I0 max. 25 mA 25 mA
NAMUR
Off-state current Ir 80 A 80 A
Extended
Output impedance Ra open-collector open-collector
Switching
Protected against polarity reversal yes yes Distance
Short circuit protected yes yes Ring Sensors
Load capacity 0.15 F 0.15 F

Repeat accuracy R 5 % 5 %

Effective operating distance sr 3.7 mm +20 %/10 % 3.7 mm +20 %/10 %


Ambient temperature range Ta 25...+70 C 25...+70 C
Frequency of operating cycles f 300 Hz 300 Hz
Utilization categories DC 12 DC 12
Function indication no no

Degree of protection per IEC 60529 IP 67 IP 65

Housing material CuZn nickel plated CuZn nickel plated


Material of sensing face PA 12 PA 12
Connection connector (cable length cable (cable length
50 m to controller) 50 m to controller)

No. of wires conductor cross section 3 0.14 mm

Recommended connector BKS-B 19/BKS-B 20

The diagnostic sensor can 1 Wiring diagrams see page 1.0.12


also be connected to an
AS-Interface through a user Please add the cable length to the ordering
module with dynamic diagnostics code for sensors with cable!
BAS S-0F0-S0-P0-S 4 (page
5.11).
03, 05 = length 3 m or 5 m
6
Connectors,
Dynamic diagnostics consists
clamps ...
of an additional signal overlaid
page 6.2 ...
on the output signal. Both the
output signal and the overlaid
diagnostic signal are sent
to the module over separate
lines.

1.5.21
Inductive Dynamic
Sensors Function Diagnostics diagnostics
Self Diagnosis Unit
with electronic output
for function diagnosis sensors
BES 113-356-SA 6-.., BES 113-3019-SA 1-..
The BES 113-FD-1 function
diagnostic unit monitors
a function diagnostic-type
proximity sensor and its
cable. A logic polls the sensor
signals for the presence of
test pulses and also checks
the functionality of the
monitor. A high-signal on the
"status/output" line indicates
errorless function, and a
low-signal tells the machine
controller that there is a fault
condition. LED's indicate
the sensor's switching state.

Faults are stored in the


monitor and must be reset Ordering code BES 113-FD-1
with a low-signal on terminal
5 (reset). Supply voltage UB 20...30 V DC
Ripple 15 %

If one BES 113-FD-1 is used Inrinsic current requirement ca. 20 mA


alone, the terminals "VI" Output voltage U0 low 0...(0.1 UB)
(3 and 4) must be jumpered (refers to 0 V) with defective sensors or device (errors)
together. high (0.5 UB)...UB
with error free function
Output current max. 50 mA
Cascading
Ambient temperature range 0...+60 C
To cascade (daisy chaining) Display LED 1 green "Ready/error" in error free condition
several BES 113-FD-1, the LED glows bright, with an error LED
output (2) of one is connected glows dark (very dim).
to the input (3) of the next Display LED 2 yellow "sensor output state"
device. The jumper between shows switching condition of the sensor.
VI is not used except for the
first unit in line. Housing attachment on rail DIN EN 50022-35
Max. cross section for connection 2 2.5 mm
Under fault conditions, Degree of protection per IEC 60529 housing IP 40, terminals IP 20
the error signal is indicated
on the last unit, and the
defective sensor is located
by the first weakly ok/error report

illuminated LED in the chain. reset

Compact and space-saving, dynamic amplifier comparator


the BES 113-FD-1 can processing
be mounted on a rail per
EN 50022-35.

Cascading
common message output

jumper

output sensor output sensor output sensor

1.5.22

You might also like