You are on page 1of 4

CYME

Power Engineering Software and Solutions

CYME 7.2 New Features

Power the Smart Grid and meet the energy needs


with the CYME Power Engineering Software

Eatons CYME is pleased to To heighten our commitment The reliability of power systems Evolving with the new
to support smart grid visions is an important aspect of system challenges of the electric
announce the release of and distributed resources analysis. CYME 7.2 features industry, the equipment
its latest CYME 7.2 Power management, the CYME 7.2 extended analytical capabilities modeling capabilities of the
Engineering Software. version brings new analysis and to assist engineers in achieving CYME software are continuously
equipment with smart controls. a more in-depth understanding refined to emulate the behavior
As part of the CYME 7 of impacts of faults and proper of devices in the most complete
Key features include:
coordination. way possible.
Series, CYME 7.2 centers on Distribution state estimator
Key features include: Enhanced equipment include:
delivering simplicity to your Battery energy storage system
fingertips while combining Short circuit IEC 61363 Corner grounded delta
Smart inverters transformer
industry-led features with Distance protection
CYME 7.2 also brings the Overhead lines and double
engineering. Whether it is to required technologies together
Low voltage cable sizing
circuits
power your smart grid or to to address the challenge of Enhanced protective device Conductors
optimize your power system complex modeling and analysis analysis
of secondary grid networks. Cables
for higher efficiency and
Key features include: Shunt capacitors
reliability, the CYME Power
Engineering Software has Network protectors with Synchronous Generators
complete relay settings
the analytical tools required
Analyses to support heavily
to help you meet your meshed networks
energy needs.
Enhancements have been Battery Energy Storage Both the battery energy storage Features of the module include:
brought to the framework and Systems and Smart Controls systems and the smart inverters Estimate function to set the
user interface to continue to are taken into account by the
Distributed energy resources reach of each protection zone
increase the friendliness and following analyses:
operators has become and the compensation factor
ease-of-use of the software.
increasingly more interested in Load Flow Load encroachment
Enhancements include: regulation controls following a Long-Term Dynamics
modification to the IEEE-1547 Protection characteristics
Embedded chart manager
standard. CYME 7.2 offers the Short-Circuit displayed on R-X diagram
New functionalities with modeling of Battery Energy
Storage Systems and Smart Secondary Grid Network
Analysis to verify relay
multi-explorer
Inverters to address related Analysis operations under both normal
Improved equipment data study needs. Such device and fault conditions
management The modeling and analytical
and controls allow to exercise
capability of the Secondary Grid Low Voltage Cable Sizing
Improved study file regulation in order to achieve
Network Analysis module have
management better voltage profile and The Low Voltage Cable Sizing
been extended in order to be an
peak-shaving. module calculates the cable size
Improved one-line diagram unmatched solution for the study
at a given location to respect the
editing The smart inverter controls are of secondary grid networks.
ampacity level, the voltage drop
added to inverter-based DER
Extended result box The network protector model limit during normal operating
systems such as WECS and PV
customization now includes complete relay conditions and the short-circuit
systems.
settings which specify: withstand capability.
Extended keyword Features:
customization Trip functions: insensitive, Features:
Six management types as remove open/block open,
Unicode supported Adheres to the standards
per IEC-61850 standard, sensitive, sensitive plus
IEC 60364-5-52 and
64-bit version available including: Volt-VAR control, non-sensitive, time delay
NEC-NFPA-70-2011
dynamic reactive current Close functions: straight
Distribution State Estimator support, watt-power factor Calculation for low voltage
closing curve, circular closing
control, volt-watt control, cables (below 1000V)
The Distribution State Estimator curve
maximum generation level and
analysis uses a sophisticated adjust power factor.
Cable size from CYME library
Other features:
algorithm which allows or NEC standard
more detailed and accurate Customizable control Polar plots are available
properties
Calculation takes into account
distribution network modeling. It to provide graphical
of conductor material,
estimates the unbalanced power representation of the trip and
Inverter control curve library insulation material and
consumption and the voltages at close regions of the network
for customized control curves manufacturer
every level of the system. protectors.
Battery energy storage systems
The analysis is able to: Robust load flow algorithm
allow bidirectional active
tailored for heavily meshed
Process voltage power flow using active power
unbalanced systems
measurements from regulation.
voltage meters and other Display of the current is
Features:
measurement types (kW, kvar, available on the polar plot after
PF, Amps) Modeling includes specific a load flow analysis.
parameters to define the
Estimate load and power flow battery management system Distance Protection
Identify errors in topology and (BMS), the battery module
CYME 7.2 offers the Distance
measurements and the overall battery energy
Protection module to assist
storage system.
Handle measurement engineers in the design and
redundancy Detailed specifications of the validation of protection schemes
AC/DC converter which involves distance relays.
Include distributed generation
Management type of the Generic distance relay types
Initialize loads storage controller include: no available are:
CYMEs Distribution State monitoring, power monitoring Mho
Estimator is based on a robust and DER monitoring
modified-augmented-nodal KD-10
Charge and discharge delays
analysis approach which is HZ
capable to:
Quadrilateral
Solve for heavily meshed
networks such as secondary RAZOA
grid networks GCX51A
Minimize the difference GCXY51
between measurements and
calculated values Reactance
Take into account options such Polygon
as line transposition, source Polygon-Mho
impedance and line charging

2 EATON CYME 7.2 New Features


Short-Circuit IEC-61363 Enhanced Protective Device For reclosers, the clearing can Python Scripting
Analysis be applied on the cumulative
A new short-circuit method is CYME 7.2 brings various
of the slow curves, the
offered as per the IEC-61363 New functionalities are added enhancements to the Python
cumulative of the fast curves,
standard for the calculation of to the Protective Device Scripting Tool:
or the cumulative of both the
AC and DC components of the Analysis module to provide a
slow and fast curves A debugger has been
short-circuit current. solution with the right tools to
integrated to offer features
address different protection and A new option has been
The calculation of this standard such as breakpoints, step-in/
coordination issues. added to the Protective
caters for the calculation of step-over, stop/continue and
Device Analysis to Verify
short-circuit levels on three- Enhancements include: variables explorer
Short-Circuit rating. It tests if
phase radial AC electrical Abnormal conditions tab the interrupting rating or the Description added to functions
installation of ships and mobile
in multi-explorer pane to momentary rating is larger and parameters in code
and fixed offshore units.
display protection problems than the short-circuit current completion
Features: (coordination, clearing, A new option is available with Tooltip display expanded to
protective device loading,
AC and DC components of the the Protective Device Analysis console
rated voltage exceeded
current are calculated from to verify cold load pickup
issues). Color-coding is Variable value inspection
fault inception to steady-state
extended to one-line diagram It is possible to define the
for three-phase symmetrical Command manager added to
and reports protection range using the
short-circuit condition keep history of commands
maximum and/or the minimum
Current adders are now part of
The initial current (Ik), short-circuit current New analyses supported:
the coordination criteria
the peak current (Ip), the Distribution State Estimator,
The coordination analysis now
breaking current (Ib) and the The short-circuit method Simultaneous Fault, Load
verifies if the number of count
DC breaking current (Idc) are and its parameters can be Growth, Short-Circuit
to lockout of a sectionalizer is
calculated specified for Branch Device IEC-61363, Network
smaller than the one of the
Coordination Configuration Optimization,
Time-domain plot available to relay or recloser upstream
Network Reduction, Network
show the short-circuit current TCC settings can be imported The coordination analysis now Diagnostic, Network
from fault inception point to into protective devices from
verifies if the actuating current Equivalent
steady-state the data repository or from
of a sectionalizer is bigger
TCC files New functions and models are
than the one of the relay or
Enhanced Fault Analysis added to the Python API
Create an equipment with recloser upstream
Besides the addition of the new specific settings onto the Python engine upgraded from
IEC-61363 calculation method, one-line diagram via a drag- Load Flow Analysis 2.7 to 3.4 to support Unicode
the analytical capability of the and-drop operation from the encoding
A new Power Factor Correction
Fault Analysis module has been data repository tool is available after a Load
further extended in CYME 7.2
Ground fault protection curve Flow simulation. The tool allows
with the following:
has been added to solid state to size capacitors and reactors
An inter-circuit fault calculation LVCBs. at a given node to achieve
for the computation of a desired power factor after
fault currents for faults
Sectionalizer model enhanced running a Load Flow analysis.
occurring between two to be taken into account
by the protective device Other enhancements in the
circuits (independent or
coordination. New fields Load Flow Analysis include:
double-circuits)
include: type (hydraulic Option to include multi-stage
Result boxes customized with or electronic), maximum switchable shunt capacitors in
appropriate keywords for both momentary current, actuating the analysis
the ANSI short-circuit and current and trip settings.
the IEC-60909 short-circuit Coordination criteria available Option to lock capacitors at
methods for sectionalizers. their current state for a given
simulation
New ANSI reports: high The Protection Loading
voltage buses current report now lists the optimal System voltage limits can be
summary, low voltage buses rating of each fuse which defined per voltage level and
current summary, low voltage would satisfy the loading per customer type
circuit breakers current criteria Load and generation scaling
summary, contact parting
Load current multiplier factor can be applied by
currents, and closing and
and load current adder are network
latching currents reports
added to the loading criteria. Option to ignore results
IEC-60909 short-circuit The worst case scenario is
downstream of three-phase
report to display abnormal compared to the maximum
fuses in the Feeder Loading
conditions and short-circuit loading allowed.
report
levels for all protective
devices.
Criteria for cable and Restore calculation parameters
conductor damage added

EATON CYME 7.2 New Features 3


CYME 7.2 Cable Modeling
CYME 7.2 provides an even
Overhead Lines
Overhead line and double-circuit
Chart Manager
An embedded chart manager,
more accurate representation of models have been enhanced to which is both user-friendly and
New Features cable installations, thanks to its
improved cable modeling.
include the possibility of using
two different neutral conductors.
powerful, is available with CYME
7.2.
Estimate function available The frequency and temperature Functions include:
to calculate the 1s withstand can be defined locally as part of
Power the Smart Grid and rating of the cable
Chart management via multi-
each overhead line equipment. explorer bar
meet the energy needs Ampacity derating factor
Equipment modeling Result sets saved to allow
with the CYME Power available
quick chart plotting without
refinement
Engineering Software Possibility to use different re-running simulations
neutrals for a cable installation Evolving with the industry,
we continue to refine the Saved charts are classified
Specify number of cables per equipment models of the CYME with associated study files
phase Power Engineering software to Charts generated with older
Additional typical installations provide models that emulates CYME versions can be
available which includes flat each devices behavior as best imported
touching, flat spacing, trefoil as possible.
Chart merging function allow
and custom CYME 7.2 includes the following easy result comparison
Typical installations with equipment enhancements:
Customization of charts
neutrals are also available Transformer configuration to (background and frame color,
include the corner-grounded grid lines, legend, font, etc).
Conductor delta
The CYME 7.2 version offers a
Creation of theme templates
Improved transformer applicable to charts
redesigned conductor library impedance estimation function
with additional estimation Export chart to JPEG format or
features for GMR and withstand Estimation function for the to clipboard
rating. reactive power limits of
synchronous generators
Other enhancements include:
Database of manufacturers for
New conductor material library bus ways
User-defined temperature Impedance estimation
value per conductor available function for bus ways
Frequency can be defined Bus ratings as per ANSI or IEC
locally by device for the standards
calculation of AC resistance
Current status of shunt
capacitors available

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 058 EN All other trademarks are property
June 2015 of their respective owners.