You are on page 1of 6

Selection Chart

Pipe
Sr.No Type Of Pipe Size(mm OD (mm) Kg/Mtr
)

1 G.I. 'C' Class pipe as per IS 1239 (Part - I)

25 34.2 2.93
32 42.9 3.79
40 48.8 4.37
50 60.8 6.19
65 76.6 7.93
80 89.5 9.9
100 115 14.5
150 166.5 21.3
G.I. 'C' Class pipe as per (IS 3589)
200 219.1 33.31
250 273 41.75

2 CI LA class, as per IS 1536

80 98 14.7
100 118 18.6
125 144 24.2
150 170 30.1
200 222 44
250 274 59.3
300 326 76.5
350 378 96.3

3 uPVC Pipe - Class 5 as per IS 4985

75 Light Weight
90 Light Weight
110 Light Weight
125 Light Weight
140 Light Weight
160 Light Weight
180 Light Weight
200 Light Weight
225 Light Weight
250 Light Weight
4 Polypropylene mineral insulated Low noise
Note : reqired insulation thickness for 56 58 1.4
clamp selection. 70 78 2.1
You can refer rubber support insert 100 110 3.55
selection chart 150 160 5.15
200 200 7.5

5 Stainless Steel Pipe - SS304 - Schedule - 5


15 21.34 0.80
20 26.67 1.02
25 33.40 1.30
Stainless Steel Pipe - SS304 - Schedule - 10
32 42.16 2.69
40 48.26 3.10
50 60.33 3.92
65 73.03 5.27
80 88.90 6.45
90 101.60 7.40
100 114.30 8.35
125 141.30 11.56
150 168.28 14.04
200 219.08 20.26
250 273.05 28.20
300 323.85 36.53
350 355.63 41.41
400 406.40 47.41

6 HDPE - PE 80 GRADE - (GEBERIT)


75 0.64
90 0.90
110 1.35
160 2.84
200 3.58
250 5.63

Please Note :
The above chart is a recommendation , please verify with your design team based on ins
always reffer our catalgoue typical instalation.
Socket
Type of Clamp Item Code
Mass

Kg

Light duty sprinkler clamp DMC998035


Light duty sprinkler clamp DMC998040
Light duty sprinkler clamp DMC998048
Light duty sprinkler clamp DMC998060
Light duty sprinkler clamp DMC998075
Light duty sprinkler clamp DMC998090
Light duty sprinkler clamp DMC998115
Light duty sprinkler clamp DMC998168

Light Duty Clevis hanger DMC999219


Light Duty Clevis hanger DMC999273

IF it is for IF it is for IF it is for


IF it is for ceiling
ceiling Channel Channel

5.5 Rubber lined split clamp DMC115090 U bolt DMC144090


7.1 Rubber lined split clamp DMC115115 U bolt DMC144115
9.2 Rubber lined split clamp DMC115140 U bolt DMC144140
11.5 Rubber lined split clamp DMC115168 U bolt DMC144168
16.8 Light Duty Clevis hanger DMC999219 U bolt DMC144219
22.9 Light Duty Clevis hanger DMC999274 U bolt DMC144274
29.8 Light Duty Clevis hanger DMC999326 U bolt DMC144326
37.5 Light Duty Clevis hanger DMC999378 U bolt DMC144378

IF it is for IF it is for IF it is for


IF it is for ceiling
ceiling Channel Channel

Rubber lined split clamp DMC115075 U bolt DMC144075


Rubber lined split clamp DMC115090 U bolt DMC144090
Rubber lined split clamp DMC115110 U bolt DMC144115
Rubber lined split clamp DMC115125 U bolt DMC144140
Light Duty Clevis hanger DMC999140 U bolt DMC144140
Light Duty Clevis hanger DMC999160 U bolt DMC144160
Light Duty Clevis hanger DMC999180 U bolt DMC144180
Light Duty Clevis hanger DMC999200 U bolt DMC144200
Light Duty Clevis hanger DMC999225 U bolt DMC144225
Light Duty Clevis hanger DMC999250 U bolt DMC144250

Rubber lined split clamp DMC115022


Rubber lined split clamp DMC115028
Rubber lined split clamp DMC115035

Rubber lined split clamp DMC115040


Rubber lined split clamp DMC115048
Rubber lined split clamp DMC115060
Rubber lined split clamp DMC115075
Rubber lined split clamp DMC115090
Rubber lined split clamp DMC115090
Rubber lined split clamp DMC115115
Rubber lined split clamp DMC115125
Rubber lined split clamp DMC115150
Light Duty Clevis hanger DMC999219
Light Duty Clevis hanger DMC999273
Light Duty Clevis hanger DMC999323
Light Duty Clevis hanger DMC999355
Light Duty Clevis hanger DMC999406

Rubber lined split clamp DMC115075


Rubber lined split clamp DMC115090
Rubber lined split clamp DMC115110
Rubber lined split clamp DMC115160
Rubber lined split clamp DMC115200
Light Duty Clevis hanger DMC999250

ign team based on installation requirement, for more details you can
Pipe Support Recommended
Safe Load
spacing for schedule 40 steel Result
KG
pipe

water service- vapor service -


M* M*

250 2.1 2.7


250 2.1 2.7
250 2.7 3.7
250 3.0 4.0
300 3.4 4.3
300 3.7 4.6
300 4.3 5.2
300 5.2 6.4

400 5.8 7.3


400 6.1 7.9

IF it is for IF it is for
ceiling - Channel - safe
safe load load
200 9500 3.7 4.6
200 9500 4.3 5.2
200 9500 4.9 5.8
200 9500 5.2 6.4
400 18000 5.8 7.3
400 28000 6.1 7.9
550 28000 7.0 9.1
550 28000 7.6 9.8

IF it is for IF it is for
ceiling - Channel - safe
safe load load
200 9500 3.4 4.3
200 9500 3.7 4.6
200 9500 4.3 5.2
200 9500 4.9 5.8
300 9500 4.9 5.8
400 9500 5.2 6.4
400 9500 5.8 7.3
400 18000 5.8 7.3
400 18000 5.8 7.3
400 28000 6.1 7.9

150 2.1 2.4


150 2.1 2.7
150 2.1 2.7

150 2.1 2.7


150 2.7 3.7
150 3.0 4.0
200 3.4 4.3
200 3.7 4.6
200 4.0 4.9
200 4.3 5.2
200 4.9 5.8
200 5.2 6.4
400 5.8 7.3
400 6.1 7.9
550 7.0 9.1
550 7.6 9.8
1200 8.2 10.7

150 3.4 4.3


200 3.7 4.6
200 4.3 5.2
200 5.2 6.4
300 5.8 7.3
400 6.1 7.9

You might also like