You are on page 1of 29

Page 1 of 29

LRFD Simon
Version 10.2.0.0 2017-02-10 12:06

Vehicle library: NSBA_Vehicle_Data.txt


Program library: NSBA_simon_library_data.txt
Agency library: NSBA_library_data.txt

Job Name: new bridge


Project Name:
Description:

check new bridge

LICENSEE: ID# U0360


Note: License expires on 2022-Aug-01 (in 1999 days).
National Steel Bridge Alliance - Perpetual
1 E Wacker Dr
Chicago IL 60601

TABLE OF CONTENTS
l Secondary Level Input Parameters

l Primary Level Input Information for Cycle: 1

Analysis Results
Section Evaluation

SECONDARY LEVEL INPUT PARAMETERS


Beam Type: I-Girder
Number of Spans: 3
Number of Girders: 5
Number of Traffic Lanes: 3
Run Option: LRFD Analysis
Redesign Performance Ratio: 0.900
Maximum Performance Ratio: 1.000
Minimum Flange Thickness: 0.750 in
Maximum Plate Thickness: 3.000 in
Distance from Slab Bottom to C.G. of Reinforcement: 3.125 in
Distance from Slab Bottom to Web Top: 0.000 in
Average Daily Truck Traffic, Single Lane: 2893
Fatigue Service Life: 75.00 years
User Input Moment Distribution Factor, Single Lane: 0.000 axles
User Input Moment Distribution Factor, Multiple Lane: 0.000 axles
User Input Shear Distribution Factor, Single Lane: 0.000 axles
User Input Shear Distribution Factor, Multiple Lane: 0.000 axles
Girder Skew: 0.000 degrees
Girder Spacing: 8.670 ft
Distance From Web to Curb, de: 3.188 ft
Girder Location: Interior
Modular Ratio, n: 0.100
Slab Compressive Strength: 0.000 psi

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 2 of 29

Reinforcement Yield Strength: 0.000 ksi


Longitudinal Stiffener Yield Strength: 50.000 ksi
Transverse and Bearing Stiffener Yield Strength: 36.000 ksi
Concrete Type: Normal Weight
Steel Surface Condition: Painted Steel
Connection Plate Type: Bolted
Slab Meet 6.10.1.7 Criteria: Yes
Uniform Dead Loads, Composite (DC): 45.000 lb/ft
Uniform Dead Loads, Utility (DW): 0.000 lb/ft
Uniform Dead Loads, Future Wearing Surface (DW): 140.000 lb/ft
Analysis Vehicle Option: HL93/User Defined
Live Load Deflection Factor: 800
Pedestrian Live Load (PL): 0.000 lb/ft
Dynamic Load Allowance, Design Vehicle: 1.330
Dynamic Load Allowance, Fatigue Vehicle: 1.150
Maximum Transverse Stiffener Spacing: 300.00000 in
One Sided Transverse Stiffeners: Yes
Shear Connector Design: No Design
Distance from Interior Reaction to Nearest Shear Connector: 0.000 ft
Web Optimization: No
Number of Variations Below Start: N/A
Number of Variations Above Start: N/A
Depth Variation Type: N/A
Depth Increment: N/A
Frequency of Cycles after which Results are Printed: Last Only
Performance Ratio Above Which Messages are Output: 0.100

PRIMARY LEVEL INPUT INFORMATION for CYCLE: 1

INPUT DATA for SPAN 1

Span Length: 60.00 ft


Hinge Location: none
Field Splice Location: none
Bottom Flange Cross Frame Spacing (Equal Spacing): 20.00 ft
Bottom Flange Cross Frame Spacing (User Input): 20.00 ft
Bracing status of Top Flange for DL1: Discretely Braced
Noncomposite Top Flange Cross Frame Spacing (Equal Spacing): 20.00 ft
Noncomposite Top Flange Cross Frame Spacing (User Input): 20.00 ft
Bracing status of Top Flange for Final: Fully Braced
Construction Lateral Moment: 0.000 kips-ft
Non Composite Uniform Dead Load: 907.000 lb/ft
Non Composite Partial Dead Load: No

Range To L Depth R Depth Thickness Yield Tee Stf


Type or Width Stress / Rebar A
(ft) (in) (in) (in) (ksi) (in^2)
Web Depth 20.00 51.000 51.000 50.0
Web Depth 40.00 51.000 51.000 50.0
Web Depth 60.00 51.000 51.000 50.0
Top Flange 60.00 12.000 0.7500 50.0 Fu = 70.0 ksi
Bot Flange 60.00 12.000 0.7500 50.0 Fu = 70.0 ksi
Conc Slab 60.00 0.000 0.0000 effective 0.00
Web Thick 20.00 0.3750 yes T.S. no L.S.

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 3 of 29

Web Thick 40.00 0.3750 yes T.S. no L.S.


Web Thick 60.00 0.3750 yes T.S. no L.S.
Web T.S. 20.00 Minimum spacing = 25.500 Reduce web? no
Web T.S. 40.00 Minimum spacing = 25.500 Reduce web? no
Web T.S. 60.00 Minimum spacing = 25.500 Reduce web? no

INPUT DATA for SPAN 2

Span Length: 75.00 ft


Hinge Location: none
Field Splice Location: 60.00 ft
Bottom Flange Cross Frame Spacing (Equal Spacing): 25.00 ft
Bottom Flange Cross Frame Spacing (User Input): 25.00 ft
Bracing status of Top Flange for DL1: Discretely Braced
Noncomposite Top Flange Cross Frame Spacing (Equal Spacing): 25.00 ft
Noncomposite Top Flange Cross Frame Spacing (User Input): 25.00 ft
Bracing status of Top Flange for Final: Fully Braced
Construction Lateral Moment: 0.000 kips-ft
Non Composite Uniform Dead Load: 907.000 lb/ft
Non Composite Partial Dead Load: No

Range To L Depth R Depth Thickness Yield Tee Stf


Type or Width Stress / Rebar A
(ft) (in) (in) (in) (ksi) (in^2)
Web Depth 25.00 51.000 51.000 50.0
Web Depth 50.00 51.000 51.000 50.0
Web Depth 75.00 51.000 51.000 50.0
Top Flange 75.00 12.000 0.7500 50.0 Fu = 70.0 ksi
Bot Flange 75.00 12.000 0.7500 50.0 Fu = 70.0 ksi
Conc Slab 75.00 0.000 0.0000 effective 0.00
Web Thick 25.00 0.3750 yes T.S. no L.S.
Web Thick 50.00 0.3750 no T.S. no L.S.
Web Thick 75.00 0.3750 yes T.S. no L.S.
Web T.S. 25.00 Minimum spacing = 25.500 Reduce web? no
Web T.S. 75.00 Minimum spacing = 25.500 Reduce web? no

ANALYSIS RESULTS (for Unfactored Loads = D and L+I)

Live Load Distribution Factors


Effect Single Lane Multi Lane
Moment 0.785 0.923
Shear 0.785 0.923

Dead Load Moments at tenth points - Units: kips-ft


Note: 'Other DC1' includes partial loads A1 and A2.

Span: 1
Point Girder Other DC1 Comp DL Utility FWS
0.0 0.0 0.0 0.0 0.0 0.0
0.1 14.6 105.1 5.2 0.0 16.2
0.2 24.7 177.6 8.8 0.0 27.4
0.3 30.3 217.4 10.8 0.0 33.6
0.4 31.3 224.5 11.1 0.0 34.7
0.5 27.7 199.1 9.9 0.0 30.7
0.6 19.6 140.9 7.0 0.0 21.7

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 4 of 29

0.7 7.0 50.1 2.5 0.0 7.7


0.8 -10.2 -73.3 -3.6 0.0 -11.3
0.9 -32.0 -229.4 -11.4 0.0 -35.4
1.0 -58.2 -418.2 -20.7 0.0 -64.6

Span: 2
Point Girder Other DC1 Comp DL Utility FWS
0.0 -58.2 -418.2 -20.7 0.0 -64.6
0.1 -26.3 -188.6 -9.4 0.0 -29.1
0.2 -1.4 -10.0 -0.5 0.0 -1.6
0.3 16.4 117.5 5.8 0.0 18.1
0.4 27.0 194.0 9.6 0.0 29.9
0.5 30.6 219.5 10.9 0.0 33.9
0.6 27.0 194.0 9.6 0.0 29.9
0.7 16.4 117.5 5.8 0.0 18.1
0.8 -1.4 -10.0 -0.5 0.0 -1.6
0.9 -26.3 -188.6 -9.4 0.0 -29.1
1.0 -58.2 -418.2 -20.7 0.0 -64.6

Live Load Moments at 10th points - Units: kips-ft

Span: 1
HL93 USER DEFINED DESIGN VEHICLE ENVELOPE FATIGUE
Point
Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 453.6 -71.6 0.0 0.0 453.6 -71.6 174.7 -26.8
0.2 763.3 -143.2 0.0 0.0 763.3 -143.2 282.2 -53.7
0.3 937.4 -214.8 0.0 0.0 937.4 -214.8 346.5 -80.5
0.4 1017.6 -286.4 0.0 0.0 1017.6 -286.4 364.3 -107.3
0.5 1001.6 -358.0 0.0 0.0 1001.6 -358.0 333.2 -134.2
0.6 910.2 -429.5 0.0 0.0 910.2 -429.5 326.4 -161.0
0.7 716.7 -501.1 0.0 0.0 716.7 -501.1 265.9 -187.8
0.8 441.4 -657.8 0.0 0.0 441.4 -657.8 165.1 -214.6
0.9 195.9 -773.3 0.0 0.0 195.9 -773.3 76.4 -241.5
1.0 157.6 -1050.2 0.0 0.0 157.6 -1050.2 55.8 -280.8

Span: 2
HL93 USER DEFINED DESIGN VEHICLE ENVELOPE FATIGUE
Point
Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum
0.0 157.6 -1050.2 0.0 0.0 157.6 -1050.2 55.8 -280.8
0.1 218.2 -639.5 0.0 0.0 218.2 -639.5 89.5 -175.3
0.2 497.6 -464.8 0.0 0.0 497.6 -464.8 192.4 -149.7
0.3 809.7 -363.4 0.0 0.0 809.7 -363.4 312.7 -124.0
0.4 1000.7 -307.2 0.0 0.0 1000.7 -307.2 377.0 -98.3
0.5 1051.1 -251.0 0.0 0.0 1051.1 -251.0 380.5 -72.6
0.6 1000.7 -307.2 0.0 0.0 1000.7 -307.2 377.0 -98.3
0.7 809.7 -363.4 0.0 0.0 809.7 -363.4 312.7 -124.0
0.8 497.6 -464.8 0.0 0.0 497.6 -464.8 192.4 -149.7
0.9 218.2 -639.5 0.0 0.0 218.2 -639.5 89.5 -175.3
1.0 157.6 -1050.2 0.0 0.0 157.6 -1050.2 55.8 -280.8

Dead Load Reactions - Negative equals Uplift - Units: kips

Support Girder Other DC1 Comp DL Utility FWS

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 5 of 29

abutment 1 2.8 20.2 1.0 0.0 3.1


pier 1 9.5 68.2 3.4 0.0 10.5
abutment 2 9.5 68.2 3.4 0.0 10.5

Dead Load Shears at tenth points - Units: kips

Span: 1
Point Girder Other DC1 Comp DL Utility FWS
0.0 2.8 20.2 1.0 0.0 3.1
0.1 2.1 14.8 0.7 0.0 2.3
0.2 1.3 9.4 0.5 0.0 1.4
0.3 0.5 3.9 0.2 0.0 0.6
0.4 -0.2 -1.5 -0.1 0.0 -0.2
0.5 -1.0 -7.0 -0.3 0.0 -1.1
0.6 -1.7 -12.4 -0.6 0.0 -1.9
0.7 -2.5 -17.9 -0.9 0.0 -2.8
0.8 -3.2 -23.3 -1.2 0.0 -3.6
0.9 -4.0 -28.7 -1.4 0.0 -4.4
1.0 -4.8 -34.2 -1.7 0.0 -5.3

Span: 2
Point Girder Other DC1 Comp DL Utility FWS
0.0 4.7 34.0 1.7 0.0 5.3
0.1 3.8 27.2 1.4 0.0 4.2
0.2 2.8 20.4 1.0 0.0 3.2
0.3 1.9 13.6 0.7 0.0 2.1
0.4 0.9 6.8 0.3 0.0 1.1
0.5 0.0 0.0 0.0 0.0 0.0
0.6 -0.9 -6.8 -0.3 0.0 -1.1
0.7 -1.9 -13.6 -0.7 0.0 -2.1
0.8 -2.8 -20.4 -1.0 0.0 -3.2
0.9 -3.8 -27.2 -1.4 0.0 -4.2
1.0 -4.7 -34.0 -1.7 0.0 -5.3

HL93 LIVE LOAD REACTIONS (Negative = Uplift) - Units: kips


NOTE: Vehicle reactions include distribution factors and dynamic load allowance
NOTE: Truck and lane reactions DO NOT include distribution factors or dynamic load allowance

Maximum Minimum Maximum Minimum Maximum Minimum


Support
Vehicle Vehicle Truck Truck Lane Lane
abutment 1 87.9 -11.9 58.4 -7.3 17.5 -3.3
pier 1 159.6 -13.5 91.6 -8.7 51.1 -3.0
abutment 2 159.6 -13.5 91.6 -8.7 51.1 -3.0

USER_DEFINED_DESIGN_VEHICLE LIVE LOAD REACTIONS (Negative = Uplift) - Units: kips


NOTE: Vehicle reactions include distribution factors and dynamic load allowance
NOTE: Truck and lane reactions DO NOT include distribution factors or dynamic load allowance

Maximum Minimum Maximum Minimum Maximum Minimum


Support
Vehicle Vehicle Truck Truck Lane Lane
abutment 1 0.0 0.0 0.0 0.0 0.0 0.0
pier 1 0.0 0.0 0.0 0.0 0.0 0.0
abutment 2 0.0 0.0 0.0 0.0 0.0 0.0

ENVELOPE LIVE LOAD REACTIONS (Negative = Uplift) - Units: kips


NOTE: Vehicle reactions include distribution factors and dynamic load allowance
NOTE: Truck and lane reactions DO NOT include distribution factors or dynamic load allowance

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 6 of 29

Maximum Minimum Maximum Minimum Maximum Minimum


Support
Vehicle Vehicle Truck Truck Lane Lane
abutment 1 87.9 -11.9 58.4 -7.3 17.5 -3.3
pier 1 159.6 -13.5 91.6 -8.7 51.1 -3.0
abutment 2 159.6 -13.5 91.6 -8.7 51.1 -3.0

FATIGUE LIVE LOAD REACTIONS (Negative = Uplift) - Units: kips


NOTE: Vehicle reactions include distribution factors and dynamic load allowance
NOTE: Truck and lane reactions DO NOT include distribution factors or dynamic load allowance

Maximum Minimum Maximum Minimum Maximum Minimum


Support
Vehicle Vehicle Truck Truck Lane Lane
abutment 1 35.0 -4.5 46.6 -5.9 0.0 0.0
pier 1 48.7 -4.4 64.7 -5.8 0.0 0.0
abutment 2 48.7 -4.4 64.7 -5.8 0.0 0.0

Live Load Shears at tenth points - Units: kips

Span: 1
HL93 USER DEFINED DESIGN VEHICLE ENVELOPE FATIGUE
Point
Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum
0.0 87.9 -11.9 0.0 0.0 87.9 -11.9 35.0 -4.5
0.1 74.0 -12.2 0.0 0.0 74.0 -12.2 29.1 -4.5
0.2 60.9 -16.5 0.0 0.0 60.9 -16.5 23.5 -5.9
0.3 48.7 -25.0 0.0 0.0 48.7 -25.0 18.4 -9.3
0.4 37.5 -33.7 0.0 0.0 37.5 -33.7 14.2 -12.8
0.5 27.4 -44.8 0.0 0.0 27.4 -44.8 11.0 -16.2
0.6 19.5 -56.9 0.0 0.0 19.5 -56.9 8.0 -20.4
0.7 13.0 -68.7 0.0 0.0 13.0 -68.7 5.4 -24.8
0.8 7.5 -80.2 0.0 0.0 7.5 -80.2 3.1 -30.2
0.9 3.1 -91.2 0.0 0.0 3.1 -91.2 1.4 -35.5
1.0 2.6 -101.4 0.0 0.0 2.6 -101.4 0.9 -40.2

Span: 2
HL93 USER DEFINED DESIGN VEHICLE ENVELOPE FATIGUE
Point
Maximum Minimum Maximum Minimum Maximum Minimum Maximum Minimum
0.0 103.4 -9.7 0.0 0.0 103.4 -9.7 41.3 -3.4
0.1 91.1 -9.8 0.0 0.0 91.1 -9.8 36.1 -3.4
0.2 78.0 -11.3 0.0 0.0 78.0 -11.3 30.4 -4.0
0.3 64.6 -18.5 0.0 0.0 64.6 -18.5 24.6 -6.9
0.4 51.4 -27.3 0.0 0.0 51.4 -27.3 18.9 -10.2
0.5 38.9 -38.9 0.0 0.0 38.9 -38.9 13.8 -13.8
0.6 27.3 -51.4 0.0 0.0 27.3 -51.4 10.2 -18.9
0.7 18.5 -64.6 0.0 0.0 18.5 -64.6 6.9 -24.6
0.8 11.3 -78.0 0.0 0.0 11.3 -78.0 4.0 -30.4
0.9 9.8 -91.1 0.0 0.0 9.8 -91.1 3.4 -36.1
1.0 9.7 -103.4 0.0 0.0 9.7 -103.4 3.4 -41.3

Dead Load Deflections at tenth points - Units: in


Note: 'Other DC1' includes partial loads A1 and A2.

Span: 1
(A) (B) (C) (B+C) (A+B+C)
Point Steel Only Other Composite Total Total
Noncomp DL DL (no DW) (No Steel) (w/ steel)

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 7 of 29

0.0 0.000 0.000 0.000 0.000 0.000


0.1 0.012 0.085 0.004 0.089 0.101
0.2 0.022 0.156 0.008 0.164 0.186
0.3 0.029 0.205 0.010 0.215 0.244
0.4 0.031 0.225 0.011 0.236 0.267
0.5 0.030 0.216 0.011 0.227 0.257
0.6 0.025 0.181 0.009 0.190 0.215
0.7 0.018 0.127 0.006 0.134 0.151
0.8 0.009 0.068 0.003 0.071 0.081
0.9 0.003 0.019 0.001 0.019 0.022
1.0 0.000 0.000 0.000 0.000 0.000

Span: 2
(A) (B) (C) (B+C) (A+B+C)
Point Steel Only Other Composite Total Total
Noncomp DL DL (no DW) (No Steel) (w/ steel)
0.0 0.000 0.000 0.000 0.000 0.000
0.1 0.006 0.041 0.002 0.043 0.049
0.2 0.017 0.122 0.006 0.128 0.146
0.3 0.029 0.207 0.010 0.217 0.246
0.4 0.037 0.268 0.013 0.281 0.319
0.5 0.040 0.290 0.014 0.305 0.345
0.6 0.037 0.268 0.013 0.281 0.319
0.7 0.029 0.207 0.010 0.217 0.246
0.8 0.017 0.122 0.006 0.128 0.146
0.9 0.006 0.041 0.002 0.043 0.049
1.0 0.000 0.000 0.000 0.000 0.000

MAXIMUM LIVE LOAD DEFLECTION per Span


Live load = HL93
(Distribution Factor for Equal Girder Loading: 0.510 axles)

Max Location from Deflection


Span Deflection Left End of Span At Hinge
(in) (Fraction) (in)
1 0.512 0.450
2 0.723 0.500

MAXIMUM LIVE LOAD DEFLECTION per Span


Live load = USER_DEFINED_DESIGN_VEHICLE
(Distribution Factor for Equal Girder Loading: 0.510 axles)

Max Location from Deflection


Span Deflection Left End of Span At Hinge
(in) (Fraction) (in)
1 0.000 0.500
2 0.000 0.500

MAXIMUM LIVE LOAD DEFLECTION per Span


Live load = ENVELOPE
(Distribution Factor for Equal Girder Loading: 0.510 axles)

Max Location from Deflection


Span Deflection Left End of Span At Hinge
(in) (Fraction) (in)
1 0.512 0.450
2 0.723 0.500

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 8 of 29

MAXIMUM LIVE LOAD DEFLECTION per Span


Live load = FATIGUE
(Distribution Factor for Equal Girder Loading: 0.510 axles)

Max Location from Deflection


Span Deflection Left End of Span At Hinge
(in) (Fraction) (in)
1 0.310 0.450
2 0.488 0.500

SECTION EVALUATION using: ** LOAD AND RESISTANCE FACTOR DESIGN **


Only behavior constraints above a performance ratio of 0.100 are listed.

Unless Noted, the 7th Edition (2014) of the AASHTO LRFD Specification is used.
No interims are evaluated.

Span 1

SECTION at Span 1, 0.0 Percent (0.00 ft) - [no plate change]

Unfactored Shears (kips) - DL1 (beam): 2.8 DL1 (other): 20.2


DL2: 1.0 DW: 3.1
+LL: 87.9 -LL: -11.9
+fatigue LL: 35.0 -fatigue LL: -4.5

Year AASHTO Article Perf Ratio Description


14 6.10.9.3.3 0.343 Nominal Shear Resistance of Stiffened Web End Panel
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 1, 33.3 Percent (20.00 ft) - [left side checked]

Unfactored Moments (kips-ft) - DL1 (beam): 31.1 DL1 (other): 223.4


DL2: 11.1 DW: 34.5
+LL: 974.6 -LL: -238.7
+fatigue LL: 357.6 -fatigue LL: -89.4

Unfactored Shears (kips) - DL1 (beam): 0.3 DL1 (other): 2.1


DL2: 0.1 DW: 0.3
+LL: 44.9 -LL: -27.9
+fatigue LL: 16.9 -fatigue LL: -10.5

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 9 of 29

DC DW Top Bottom Slab Reinf Flexure


LF LF Flange Flange
STRENGTH_I 0.90 0.65 3.04 -3.04 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -40.63 40.63 0.00 0.00 positive
SERVICE_II 1.00 1.00 0.20 -0.20 0.00 0.00 negative
SERVICE_II 1.00 1.00 -30.48 30.48 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 -6.93 6.93 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -6.97 6.97 N/A N/A positive
DECK_POUR_2 1.40 N/A -6.93 6.93 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -5.84 -10.43 2.61 13.04 5.84 10.43 -2.61 13.04
FATIGUE_II -5.84 -5.22 1.30 6.52 5.84 5.22 -1.30 6.52

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.536 25.5 2570.89 -156.2 82.05 -46.37
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 2089.3 82.05 -46.37
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -10.1 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1567.1 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -134.2 28.13* -12.91*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 536.4 28.13* -12.91*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -67.1 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 268.2 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.112 25.5 2570.89 356.4 3.28 2.11
DECK_POUR_1 (positive) 1.000 N/A 1.109 25.5 2570.89 358.3 3.41 2.19
DECK_POUR_2 (positive) 1.000 N/A 1.113 25.5 2570.89 356.4 3.27 2.10

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.139 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.139 Compression Flange Local Buckling (Constructibility)
14 6.10.3.2.1 0.167 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.2 0.139 Tension Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.139 Compression Flange Nominal Yielding (Deck Pour 1)

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 10 of 29

14 6.10.3.2.1 0.139 Compression Flange Local Buckling (Deck Pour 1)


14 6.10.3.2.1 0.169 Compression Flange Lateral Torsional Buckling (Deck Pour 1)
14 6.10.3.2.2 0.139 Tension Flange Nominal Yielding (Deck Pour 1)
14 6.10.3.2.1 0.139 Compression Flange Nominal Yielding (Deck Pour 2)
14 6.10.3.2.1 0.139 Compression Flange Local Buckling (Deck Pour 2)
14 6.10.3.2.1 0.167 Compression Flange Lateral Torsional Buckling (Deck Pour 2)
14 6.10.3.2.2 0.139 Tension Flange Nominal Yielding (Deck Pour 2)
14 6.10.4.2.2 0.762 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.762 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.7.2.2 0.813 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.813 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.148 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.6.1.2 0.543 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.792 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.952 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.792 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 1, 41.8 Percent (25.08 ft) - [no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): 31.0 DL1 (other): 222.3


DL2: 11.0 DW: 34.4
+LL: 1021.8 -LL: -299.3
+fatigue LL: 362.3 -fatigue LL: -112.1

Unfactored Shears (kips) - DL1 (beam): -0.3 DL1 (other): -2.5


DL2: -0.1 DW: -0.4
+LL: 35.6 -LL: -35.5
+fatigue LL: 13.6 -fatigue LL: -13.4

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 0.90 0.65 5.13 -5.13 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -42.21 42.21 0.00 0.00 positive

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 11 of 29

SERVICE_II 1.00 1.00 1.76 -1.76 0.00 0.00 negative


SERVICE_II 1.00 1.00 -31.64 31.64 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 -6.90 6.90 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -6.95 6.95 N/A N/A positive
DECK_POUR_2 1.40 N/A -6.90 6.90 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -5.81 -10.57 3.27 13.84 5.81 10.57 -3.27 13.84
FATIGUE_II -5.81 -5.28 1.64 6.92 5.81 5.28 -1.64 6.92

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.536 25.5 2570.89 -263.6 59.40 -66.40
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 2170.1 59.40 -66.40
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -90.4 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1627.0 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -168.2 17.01* -23.45*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 543.5 17.01* -23.45*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -84.1 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 271.7 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.112 25.5 2570.89 354.6 -2.54 -3.95
DECK_POUR_1 (positive) 1.000 N/A 1.109 25.5 2570.89 357.1 -2.53 -3.94
DECK_POUR_2 (positive) 1.000 N/A 1.113 25.5 2570.89 354.8 -2.62 -4.08

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.138 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.138 Compression Flange Local Buckling (Constructibility)
14 6.10.3.2.1 0.167 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.2 0.138 Tension Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.139 Compression Flange Nominal Yielding (Deck Pour 1)
14 6.10.3.2.1 0.139 Compression Flange Local Buckling (Deck Pour 1)
14 6.10.3.2.1 0.168 Compression Flange Lateral Torsional Buckling (Deck Pour 1)
14 6.10.3.2.2 0.139 Tension Flange Nominal Yielding (Deck Pour 1)
14 6.10.3.2.1 0.138 Compression Flange Nominal Yielding (Deck Pour 2)

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 12 of 29

14 6.10.3.2.1 0.138 Compression Flange Local Buckling (Deck Pour 2)


14 6.10.3.2.1 0.167 Compression Flange Lateral Torsional Buckling (Deck Pour 2)
14 6.10.3.2.2 0.138 Tension Flange Nominal Yielding (Deck Pour 2)
14 6.10.4.2.2 0.791 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.791 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.7.2.2 0.844 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.844 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.8.2.2 0.103 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.103 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.103 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.120 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.6.1.2 0.577 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.840 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 1.011 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.840 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 1, 66.7 Percent (40.00 ft) - [right side checked]

Unfactored Moments (kips-ft) - DL1 (beam): 11.7 DL1 (other): 84.0


DL2: 4.2 DW: 12.9
+LL: 790.3 -LL: -467.8
+fatigue LL: 290.5 -fatigue LL: -178.9

Unfactored Shears (kips) - DL1 (beam): -2.2 DL1 (other): -16.1


DL2: -0.8 DW: -2.5
+LL: 15.1 -LL: -64.8
+fatigue LL: 6.2 -fatigue LL: -23.2

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 0.90 0.65 14.01 -14.01 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -29.70 29.70 0.00 0.00 positive
SERVICE_II 1.00 1.00 9.63 -9.63 0.00 0.00 negative

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 13 of 29

SERVICE_II 1.00 1.00 -22.17 22.17 0.00 0.00 positive


CONSTRUCTION 1.40 0.00 -2.61 2.61 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -2.68 2.68 N/A N/A positive
DECK_POUR_2 1.40 N/A -2.61 2.61 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -2.19 -8.48 5.22 13.69 2.19 8.48 -5.22 13.69
FATIGUE_II -2.19 -4.24 2.61 6.85 2.19 4.24 -2.61 6.85

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.478 25.5 2570.89 -720.3 7.51 -141.07
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 1527.2 7.51 -141.07
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -495.3 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1140.2 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -268.3 -12.28* -56.47*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 435.8 -12.28* -56.47*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -134.2 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 217.9 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.750 25.5 2570.89 134.0 -16.49 -25.65
DECK_POUR_1 (positive) 1.000 N/A 1.750 25.5 2570.89 137.9 -16.40 -25.51
DECK_POUR_2 (positive) 1.000 N/A 1.750 25.5 2570.89 134.0 -16.49 -25.65

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.4.2.2 0.554 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.554 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.241 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.241 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.193 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.7.2.2 0.594 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.594 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.8.2.2 0.280 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.280 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 14 of 29

14 6.10.8.1.2 0.280 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.255 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.103 Special Fatigue Requirement for Webs
14 6.6.1.2 0.571 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.571 Fatigue-I: Top Flange Base Metal - Cat A
14 6.6.1.2 0.831 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.831 Fatigue-I: Top Flange/Web Fillet Weld - Cat B
14 6.6.1.2 1.000 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 1.000 Fatigue-I: Trans Stiff Weld near Top Flange - Cat C'
14 6.6.1.2 0.831 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
14 6.6.1.2 0.831 Fatigue-I: Conn Pl at Top Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 1, 100.0 Percent (60.00 ft) - [no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): -58.2 DL1 (other): -418.2


DL2: -20.7 DW: -64.6
+LL: 157.6 -LL: -1050.2
+fatigue LL: 55.8 -fatigue LL: -280.8

Unfactored Shears (kips) - DL1 (beam): -4.8 DL1 (other): -34.2


DL2: -1.7 DW: -5.3
+LL: 2.6 -LL: -101.4
+fatigue LL: 0.9 -fatigue LL: -40.2

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 N/A N/A
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 N/A N/A
S to_top_of_top_flange in^3 -617 -617 -617 -617 N/A N/A
S to_bottom_of_bottom_flange in^3 617 617 617 617 N/A N/A
S to_top_of_slab in^3 -635 -635 N/A N/A N/A
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 1.25 1.50 49.71 -49.71 0.00 0.00 negative
SERVICE_II 1.00 1.00 37.48 -37.48 0.00 0.00 negative
CONSTRUCTION 1.40 0.00 12.97 -12.97 0.00 0.00 negative
CONSTRUCTION Lateral 0.00 0.00 negative
DECK_POUR_1 1.40 N/A 12.41 -12.41 N/A N/A negative
DECK_POUR_2 1.40 N/A 12.97 -12.97 N/A N/A negative

Fatigue Stresses (ksi) -

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 15 of 29

Top Flange Bottom Flange


DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I 10.92 -1.63 8.19 9.82 -10.92 1.63 -8.19 9.82
FATIGUE_II 10.92 -0.81 4.10 4.91 -10.92 0.81 -4.10 4.91

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.478 25.5 2570.89 -2556.1 -35.53 -236.27
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -1927.0 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -421.2 -44.65* -106.30*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 83.7 -44.65* -106.30*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -210.6 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 41.9 N/A N/A
CONSTRUCTION (negative) 1.000 N/A 1.750 25.5 2570.89 -667.0 -35.10 -54.60
DECK_POUR_1 (negative) 1.000 N/A 1.750 25.5 2570.89 -638.3 -30.15 -46.90
DECK_POUR_2 (negative) 1.000 N/A 1.750 25.5 2570.89 -666.8 -35.10 -54.60

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.259 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.259 Compression Flange Local Buckling (Constructibility)
14 6.10.3.2.1 0.259 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.2 0.259 Tension Flange Nominal Yielding (Constructibility)
14 6.10.4.2.2 0.937 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.937 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.750 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.8.2.2 0.994 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.994 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.994 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.427 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.193 Special Fatigue Requirement for Webs
14 6.6.1.2 0.409 Fatigue-I: Top Flange Base Metal - Cat A

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 16 of 29

14 6.6.1.2 0.596 Fatigue-I: Top Flange/Web Fillet Weld - Cat B


14 6.6.1.2 0.795 Fatigue-I: Bearing Stiffener at Top Flange - Cat C'
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

Span 2

SECTION at Span 2, 0.0 Percent (0.00 ft) - [no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): -58.2 DL1 (other): -418.2


DL2: -20.7 DW: -64.6
+LL: 157.6 -LL: -1050.2
+fatigue LL: 55.8 -fatigue LL: -280.8

Unfactored Shears (kips) - DL1 (beam): 4.7 DL1 (other): 34.0


DL2: 1.7 DW: 5.2
+LL: 103.4 -LL: -9.7
+fatigue LL: 41.3 -fatigue LL: -3.4

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 N/A N/A
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 N/A N/A
S to_top_of_top_flange in^3 -617 -617 -617 -617 N/A N/A
S to_bottom_of_bottom_flange in^3 617 617 617 617 N/A N/A
S to_top_of_slab in^3 -635 -635 N/A N/A N/A
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 1.25 1.50 49.71 -49.71 0.00 0.00 negative
SERVICE_II 1.00 1.00 37.48 -37.48 0.00 0.00 negative
CONSTRUCTION 1.40 0.00 12.97 -12.97 0.00 0.00 negative
CONSTRUCTION Lateral 0.00 0.00 negative
DECK_POUR_1 1.40 N/A 12.41 -12.41 N/A N/A negative
DECK_POUR_2 1.40 N/A 12.97 -12.97 N/A N/A negative

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I 10.92 -1.63 8.19 9.82 -10.92 1.63 -8.19 9.82
FATIGUE_II 10.92 -0.81 4.10 4.91 -10.92 0.81 -4.10 4.91

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 17 of 29

Rh Rb Cb Dc My Mu Vu, max Vu, min


(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.585 25.5 2570.89 -2556.1 239.25 22.77
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -1927.0 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -421.2 107.55* 40.50*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 83.7 107.55* 40.50*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -210.6 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 41.9 N/A N/A
CONSTRUCTION (negative) 1.000 N/A 1.750 25.5 2570.89 -667.0 54.18 34.83
DECK_POUR_1 (negative) 1.000 N/A 1.750 25.5 2570.89 -638.3 44.66 28.71
DECK_POUR_2 (negative) 1.000 N/A 1.750 25.5 2570.89 -666.8 54.18 34.83

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.259 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.259 Compression Flange Local Buckling (Constructibility)
14 6.10.3.2.1 0.259 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.2 0.259 Tension Flange Nominal Yielding (Constructibility)
14 6.10.4.2.2 0.937 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.937 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.750 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.8.2.2 0.994 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.994 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.994 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.432 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.196 Special Fatigue Requirement for Webs
14 6.6.1.2 0.409 Fatigue-I: Top Flange Base Metal - Cat A
14 6.6.1.2 0.596 Fatigue-I: Top Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.795 Fatigue-I: Bearing Stiffener at Top Flange - Cat C'
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 20.0 Percent (15.00 ft) - [field splice location, no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): -1.4 DL1 (other): -10.0


DL2: -0.5 DW: -1.6
+LL: 497.6 -LL: -464.8
+fatigue LL: 192.4 -fatigue LL: -149.7

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 18 of 29

Unfactored Shears (kips) - DL1 (beam): 2.8 DL1 (other): 20.4


DL2: 1.0 DW: 3.2
+LL: 78.0 -LL: -11.3
+fatigue LL: 30.4 -fatigue LL: -4.0

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 1.25 1.50 16.16 -16.16 0.00 0.00 negative
STRENGTH_I 0.90 0.65 -16.71 16.71 0.00 0.00 positive
SERVICE_II 1.00 1.00 12.01 -12.01 0.00 0.00 negative
SERVICE_II 1.00 1.00 -12.32 12.32 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 0.31 -0.31 0.00 0.00 negative
CONSTRUCTION Lateral 0.00 0.00 negative
DECK_POUR_1 1.40 N/A 0.45 -0.45 N/A N/A negative
DECK_POUR_2 1.40 N/A 0.31 -0.31 N/A N/A negative

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I 0.26 -5.61 4.37 9.98 -0.26 5.61 -4.37 9.98
FATIGUE_II 0.26 -2.81 2.18 4.99 -0.26 2.81 -2.18 4.99

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.585 25.5 2570.89 -830.7 171.55 4.08
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 859.1 171.55 4.08
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -617.7 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 633.4 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -224.6 73.00* 21.40*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 288.6 73.00* 21.40*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -112.3 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 144.3 N/A N/A
CONSTRUCTION (negative) 1.000 N/A 1.750 25.5 2570.89 -16.0 32.48 20.88
DECK_POUR_1 (negative) 1.000 N/A 1.750 25.5 2570.89 -23.1 32.48 20.88

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 19 of 29

DECK_POUR_2 (negative) 1.000 N/A 1.750 25.5 2570.89 -16.0 32.48 20.88

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Construction)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.005 = ft / ( 0.84 * Fu )
14 6.10.4.2.2 0.308 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.308 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.300 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.300 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.240 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.7.2.2 0.334 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.334 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.1.8 0.334 Net Section Fracture; Check Tension Flange stress against Fy ONLY (Strength-I)
14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Strength-I)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.284 = ft / ( 0.84 * Fu )
14 6.10.8.2.2 0.323 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.323 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.323 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.1.8 0.323 Net Section Fracture; Check Tension Flange stress against Fy ONLY (Strength-I)
14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Strength-I)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.275 = ft / ( 0.84 * Fu )
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.310 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.133 Special Fatigue Requirement for Webs
14 6.6.1.2 0.416 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.416 Fatigue-I: Top Flange Base Metal - Cat A
14 6.6.1.2 0.606 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.606 Fatigue-I: Top Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.729 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.729 Fatigue-I: Trans Stiff Weld near Top Flange - Cat C'
14 6.6.1.2 0.606 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
14 6.6.1.2 0.606 Fatigue-I: Conn Pl at Top Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 33.3 Percent (25.00 ft) - [left side checked]

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 20 of 29

Unfactored Moments (kips-ft) - DL1 (beam): 20.7 DL1 (other): 148.7


DL2: 7.3 DW: 22.9
+LL: 886.8 -LL: -339.6
+fatigue LL: 340.4 -fatigue LL: -115.4

Unfactored Shears (kips) - DL1 (beam): 1.6 DL1 (other): 11.3


DL2: 0.6 DW: 1.7
+LL: 60.2 -LL: -21.3
+fatigue LL: 22.7 -fatigue LL: -8.0

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 0.90 0.65 8.18 -8.18 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -35.15 35.15 0.00 0.00 positive
SERVICE_II 1.00 1.00 4.70 -4.70 0.00 0.00 negative
SERVICE_II 1.00 1.00 -26.30 26.30 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 -4.61 4.61 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -4.47 4.47 N/A N/A positive
DECK_POUR_2 1.40 N/A -4.61 4.61 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -3.88 -9.93 3.37 13.30 3.88 9.93 -3.37 13.30
FATIGUE_II -3.88 -4.96 1.68 6.65 3.88 4.96 -1.68 6.65

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.000 25.5 2570.89 -420.4 124.77 -23.93
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 1807.2 124.77 -23.93
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -241.9 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1352.5 N/A N/A

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 21 of 29

FATIGUE_I (negative) N/A N/A N/A N/A N/A -173.2 49.26* 3.29*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 510.5 49.26* 3.29*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -86.6 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 255.3 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.000 25.5 2570.89 237.2 18.08 11.62
DECK_POUR_1 (positive) 1.000 N/A 1.000 25.5 2570.89 230.1 18.08 11.62
DECK_POUR_2 (positive) 1.000 N/A 1.000 25.5 2570.89 237.2 18.08 11.62

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.141 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.1 0.137 Compression Flange Lateral Torsional Buckling (Deck Pour 1)
14 6.10.3.2.1 0.141 Compression Flange Lateral Torsional Buckling (Deck Pour 2)
14 6.10.4.2.2 0.658 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.658 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.118 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.118 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.7.2.2 0.703 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.703 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.8.2.2 0.164 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.250 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.164 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.225 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.6.1.2 0.554 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.807 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.971 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.807 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 50.0 Percent (37.50 ft) - [no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): 30.6 DL1 (other): 219.5


DL2: 10.9 DW: 33.9
+LL: 1051.1 -LL: -251.0
+fatigue LL: 380.5 -fatigue LL: -72.6

Unfactored Shears (kips) - DL1 (beam): 0.0 DL1 (other): 0.0

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 22 of 29

DL2: 0.0 DW: 0.0


+LL: 38.9 -LL: -38.9
+fatigue LL: 13.8 -fatigue LL: -13.8

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 0.90 0.65 3.55 -3.55 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -43.11 43.11 0.00 0.00 positive
SERVICE_II 1.00 1.00 0.61 -0.61 0.00 0.00 negative
SERVICE_II 1.00 1.00 -32.31 32.31 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 -6.81 6.81 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -6.67 6.67 N/A N/A positive
DECK_POUR_2 1.40 N/A -6.81 6.81 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -5.74 -11.10 2.12 13.22 5.74 11.10 -2.12 13.22
FATIGUE_II -5.74 -5.55 1.06 6.61 5.74 5.55 -1.06 6.61

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.000 25.5 2570.89 -182.3 68.08 -68.08
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 2216.5 68.08 -68.08
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -31.4 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1661.3 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -108.9 20.70* -20.70*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 570.8 20.70* -20.70*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -54.5 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 285.4 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.000 25.5 2570.89 350.1 0.00 0.00
DECK_POUR_1 (positive) 1.000 N/A 1.000 25.5 2570.89 343.1 0.00 0.00
DECK_POUR_2 (positive) 1.000 N/A 1.000 25.5 2570.89 350.3 0.00 0.00

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 23 of 29

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.136 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.136 Compression Flange Local Buckling (Constructibility)
14 6.10.3.2.1 0.209 Compression Flange Lateral Torsional Buckling (Constructibility)
14 6.10.3.2.2 0.136 Tension Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.133 Compression Flange Nominal Yielding (Deck Pour 1)
14 6.10.3.2.1 0.133 Compression Flange Local Buckling (Deck Pour 1)
14 6.10.3.2.1 0.204 Compression Flange Lateral Torsional Buckling (Deck Pour 1)
14 6.10.3.2.2 0.133 Tension Flange Nominal Yielding (Deck Pour 1)
14 6.10.3.2.1 0.136 Compression Flange Nominal Yielding (Deck Pour 2)
14 6.10.3.2.1 0.136 Compression Flange Local Buckling (Deck Pour 2)
14 6.10.3.2.1 0.209 Compression Flange Lateral Torsional Buckling (Deck Pour 2)
14 6.10.3.2.2 0.136 Tension Flange Nominal Yielding (Deck Pour 2)
14 6.10.4.2.2 0.808 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.808 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.7.2.2 0.862 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.862 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.8.2.3 0.109 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.2 0.499 Nominal Shear Resistance of Unstiffened Web
14 6.6.1.2 0.551 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.803 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.803 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 66.7 Percent (50.00 ft) - [right side checked]

Unfactored Moments (kips-ft) - DL1 (beam): 20.7 DL1 (other): 148.7


DL2: 7.3 DW: 22.9
+LL: 886.8 -LL: -339.6
+fatigue LL: 340.4 -fatigue LL: -115.4

Unfactored Shears (kips) - DL1 (beam): -1.6 DL1 (other): -11.3


DL2: -0.6 DW: -1.7
+LL: 21.3 -LL: -60.2
+fatigue LL: 8.0 -fatigue LL: -22.7

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 24 of 29

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 0.90 0.65 8.18 -8.18 0.00 0.00 negative
STRENGTH_I 1.25 1.50 -35.15 35.15 0.00 0.00 positive
SERVICE_II 1.00 1.00 4.70 -4.70 0.00 0.00 negative
SERVICE_II 1.00 1.00 -26.30 26.30 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 -4.61 4.61 0.00 0.00 positive
CONSTRUCTION/DECK POUR Lateral 0.00 0.00 N/A N/A positive
DECK_POUR_1 1.40 N/A -4.47 4.47 N/A N/A positive
DECK_POUR_2 1.40 N/A -4.61 4.61 N/A N/A positive

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I -3.88 -9.93 3.37 13.30 3.88 9.93 -3.37 13.30
FATIGUE_II -3.88 -4.96 1.68 6.65 3.88 4.96 -1.68 6.65

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.585 25.5 2570.89 -420.4 23.93 -124.77
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 1807.2 23.93 -124.77
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -241.9 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 1352.5 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -173.2 -3.29* -49.26*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 510.5 -3.29* -49.26*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -86.6 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 255.3 N/A N/A
CONSTRUCTION (positive) 1.000 N/A 1.750 25.5 2570.89 237.2 -11.62 -18.08
DECK_POUR_1 (positive) 1.000 N/A 1.750 25.5 2570.89 230.1 -11.62 -18.08
DECK_POUR_2 (positive) 1.000 N/A 1.750 25.5 2570.89 237.2 -11.62 -18.08

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 25 of 29

Dc = Depth of web in compression


My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.4.2.2 0.658 Top Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.658 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.118 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.118 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.7.2.2 0.703 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.703 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.8.2.2 0.164 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.164 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.164 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.225 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.6.1.2 0.554 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.807 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.971 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.807 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 80.0 Percent (60.00 ft) - [field splice location, no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): -1.4 DL1 (other): -10.0


DL2: -0.5 DW: -1.6
+LL: 497.6 -LL: -464.8
+fatigue LL: 192.4 -fatigue LL: -149.7

Unfactored Shears (kips) - DL1 (beam): -2.8 DL1 (other): -20.4


DL2: -1.0 DW: -3.2
+LL: 11.3 -LL: -78.0
+fatigue LL: 4.0 -fatigue LL: -30.4

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 16197 16197
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 26.25 26.25
S to_top_of_top_flange in^3 -617 -617 -617 -617 -617 -617
S to_bottom_of_bottom_flange in^3 617 617 617 617 617 617
S to_top_of_slab in^3 -635 -635 N/A -635 -635
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 26 of 29

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 1.25 1.50 16.16 -16.16 0.00 0.00 negative
STRENGTH_I 0.90 0.65 -16.71 16.71 0.00 0.00 positive
SERVICE_II 1.00 1.00 12.01 -12.01 0.00 0.00 negative
SERVICE_II 1.00 1.00 -12.32 12.32 0.00 0.00 positive
CONSTRUCTION 1.40 0.00 0.31 -0.31 0.00 0.00 negative
CONSTRUCTION Lateral 0.00 0.00 negative
DECK_POUR_1 1.40 N/A 0.45 -0.45 N/A N/A negative
DECK_POUR_2 1.40 N/A 0.31 -0.31 N/A N/A negative

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I 0.26 -5.61 4.37 9.98 -0.26 5.61 -4.37 9.98
FATIGUE_II 0.26 -2.81 2.18 4.99 -0.26 2.81 -2.18 4.99

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.585 25.5 2570.89 -830.7 -4.08 -171.55
STRENGTH_I (positive) 1.000 1.000 N/A 25.5 2570.89 859.1 -4.08 -171.55
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -617.7 N/A N/A
SERVICE_II (positive) 1.000 N/A N/A 25.5 N/A 633.4 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -224.6 -21.40* -73.00*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 288.6 -21.40* -73.00*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -112.3 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 144.3 N/A N/A
CONSTRUCTION (negative) 1.000 N/A 1.750 25.5 2570.89 -16.0 -20.88 -32.48
DECK_POUR_1 (negative) 1.000 N/A 1.750 25.5 2570.89 -23.1 -20.88 -32.48
DECK_POUR_2 (negative) 1.000 N/A 1.750 25.5 2570.89 -16.0 -20.88 -32.48

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Construction)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.005 = ft / ( 0.84 * Fu )
14 6.10.4.2.2 0.308 Top Flange Service Limit State Permanent Deflections, Positive Flexure

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 27 of 29

14 6.10.4.2.2 0.308 Bottom Flange Service Limit State Permanent Deflections, Positive Flexure
14 6.10.4.2.2 0.300 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.300 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.240 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.7.2.2 0.334 Flexure, Noncompact, Composite, Positive Flexure, Top Flange
14 6.10.7.2.2 0.334 Flexure, Noncompact, Composite, Positive Flexure, Bottom Flange
14 6.10.7.3 1.173 Flexure - Composite, Positive Flexure, Ductility
14 6.10.1.8 0.334 Net Section Fracture; Check Tension Flange stress against Fy ONLY (Strength-I)
14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Strength-I)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.284 = ft / ( 0.84 * Fu )
14 6.10.8.2.2 0.323 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.323 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.323 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.1.8 0.323 Net Section Fracture; Check Tension Flange stress against Fy ONLY (Strength-I)
14 6.10.1.8 warning LRFD Simon does not check 0.84 * ( An / Ag ) * Fu (Strength-I)
informational After field splice design, the user must ensure that the An / Ag of the
informational tension flange exceeds 0.275 = ft / ( 0.84 * Fu )
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.310 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.133 Special Fatigue Requirement for Webs
14 6.6.1.2 0.416 Fatigue-I: Bottom Flange Base Metal - Cat A
14 6.6.1.2 0.416 Fatigue-I: Top Flange Base Metal - Cat A
14 6.6.1.2 0.606 Fatigue-I: Bottom Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.606 Fatigue-I: Top Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.729 Fatigue-I: Trans Stiff Weld near Bottom Flange - Cat C'
14 6.6.1.2 0.729 Fatigue-I: Trans Stiff Weld near Top Flange - Cat C'
14 6.6.1.2 0.606 Fatigue-I: Conn Pl at Bot Flange (Bolted) - Cat B
14 6.6.1.2 0.606 Fatigue-I: Conn Pl at Top Flange (Bolted) - Cat B
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

SECTION at Span 2, 100.0 Percent (75.00 ft) - [no plate change]

Unfactored Moments (kips-ft) - DL1 (beam): -58.2 DL1 (other): -418.2


DL2: -20.7 DW: -64.6
+LL: 157.6 -LL: -1050.2
+fatigue LL: 55.8 -fatigue LL: -280.8

Unfactored Shears (kips) - DL1 (beam): -4.7 DL1 (other): -34.0


DL2: -1.7 DW: -5.2
+LL: 9.7 -LL: -103.4
+fatigue LL: 3.4 -fatigue LL: -41.3

Plate+nSlab Plate+3nSlab
Plate+nSlab Plate+3nSlab
Property Unit Plate Plate+Rebar (Strength (Strength
(Other LS) (Other LS)
LS) LS)
moment_of_inertia in^4 16197 16197 16197 16197 N/A N/A
neutral_axis_from_bottom_of_beam in 26.25 26.25 26.25 26.25 N/A N/A

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 28 of 29

S to_top_of_top_flange in^3 -617 -617 -617 -617 N/A N/A


S to_bottom_of_bottom_flange in^3 617 617 617 617 N/A N/A
S to_top_of_slab in^3 -635 -635 N/A N/A N/A
S to_cg_of_reinforcement in^3 N/A
longit_stiffness_parameter in^4 4034

Factored Stresses (ksi) -


DC DW Top Bottom Slab Reinf Flexure
LF LF Flange Flange
STRENGTH_I 1.25 1.50 49.71 -49.71 0.00 0.00 negative
SERVICE_II 1.00 1.00 37.48 -37.48 0.00 0.00 negative
CONSTRUCTION 1.40 0.00 12.97 -12.97 0.00 0.00 negative
CONSTRUCTION Lateral 0.00 0.00 negative
DECK_POUR_1 1.40 N/A 12.41 -12.41 N/A N/A negative
DECK_POUR_2 1.40 N/A 12.97 -12.97 N/A N/A negative

Fatigue Stresses (ksi) -


Top Flange Bottom Flange
DL LL+ LL- Range DL LL+ LL- Range
FATIGUE_I 10.92 -1.63 8.19 9.82 -10.92 1.63 -8.19 9.82
FATIGUE_II 10.92 -0.81 4.10 4.91 -10.92 0.81 -4.10 4.91

Legend:
DL = Total unfactored dead load stress
LL+ = Factored positive live load stress
LL- = Factored negative live load stress
Range = Total factored live load stress range
Negative stresses are compressive

Detailed Information -
Rh Rb Cb Dc My Mu Vu, max Vu, min
(in) (kips-ft) (kips-ft) (kips) (kips)
STRENGTH_I (negative) 1.000 1.000 1.585 25.5 2570.89 -2556.1 -22.77 -239.25
SERVICE_II (negative) 1.000 N/A N/A 25.5 N/A -1927.0 N/A N/A
FATIGUE_I (negative) N/A N/A N/A N/A N/A -421.2 -40.50* -107.55*
FATIGUE_I (positive) N/A N/A N/A N/A N/A 83.7 -40.50* -107.55*
FATIGUE_II (negative) N/A N/A N/A N/A N/A -210.6 N/A N/A
FATIGUE_II (positive) N/A N/A N/A N/A N/A 41.9 N/A N/A
CONSTRUCTION (negative) 1.000 N/A 1.750 25.5 2570.89 -667.0 -34.83 -54.18
DECK_POUR_1 (negative) 1.000 N/A 1.750 25.5 2570.89 -638.3 -28.71 -44.66
DECK_POUR_2 (negative) 1.000 N/A 1.750 25.5 2570.89 -666.8 -34.83 -54.18

Legend:
Rh = Hybrid factor
Rb = Web load-shedding factor
Cb = Moment gradient factor
Dc = Depth of web in compression
My = Yield moment
Mu = Total factored moment
Vu, max = Maximum total factored shear (NOTE: this value does not depend on the flexure of the section)
* = This value includes unfactored permanent dead load shear

Year AASHTO Article Perf Ratio Description


14 6.10.3.2.1 0.259 Compression Flange Nominal Yielding (Constructibility)
14 6.10.3.2.1 0.259 Compression Flange Local Buckling (Constructibility)

file:///C:/Users/lu_01/Desktop/final_bridge_interior%20data_output.xml 2/10/2017
Page 29 of 29

14 6.10.3.2.1 0.259 Compression Flange Lateral Torsional Buckling (Constructibility)


14 6.10.3.2.2 0.259 Tension Flange Nominal Yielding (Constructibility)
14 6.10.4.2.2 0.937 Top Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.937 Bottom Flange Service Limit State Permanent Deflections, Negative Flexure
14 6.10.4.2.2 0.750 Compression Flange Service Limit State Bend-Buckling, Negative Flexure
14 6.10.8.2.2 0.994 Flex Resist: discretely braced flange in comp, local buckling, Negative Flexure
14 6.10.8.2.3 0.994 Flex Resist: discretely braced flange in comp, LT buckling, Negative Flexure
14 6.10.8.1.2 0.994 Flexural Resistance: discretely braced flange in tension, Negative Flexure
14 6.10.2.2-1 0.667 Top flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Top flange b >= D/6
14 6.10.2.2-3 0.550 Top flange t >= 1.1*tw
14 6.10.2.2-1 0.667 Bottom flange b/(2*t) <= 12.0
14 6.10.2.2-2 0.708 Bottom flange b >= D/6
14 6.10.2.2-3 0.550 Bottom flange t >= 1.1*tw
14 6.10.9.3.2 0.432 Nominal Shear Resistance of Stiffened Web Interior Panel
14 6.10.5.3 0.196 Special Fatigue Requirement for Webs
14 6.6.1.2 0.409 Fatigue-I: Top Flange Base Metal - Cat A
14 6.6.1.2 0.596 Fatigue-I: Top Flange/Web Fillet Weld - Cat B
14 6.6.1.2 0.795 Fatigue-I: Bearing Stiffener at Top Flange - Cat C'
informational Minimum User Bottom Flange Thickness Encountered.
informational Minimum User Top Flange Thickness Encountered.

The Maximum Performance Ratio for Cycle 1 is 1.173

The Design for Cycle 1 is UNACCEPTABLE (Weight = 12.305 tons)