Quote No.

KTSC152387
Revision R0

Width 51300 mm (C/c of


Width Module 2@25650 mm (C/c
Building Type MS-1
End Wall Bay Spacing 8@6412.5 mm (C/c
Roof Slope
Length 79410 mm (C/c of
Side Wall Bay Spacing 11@7219.09 mmFar
( End Wall
Gable Condition Closed
Clear height U/S OF KNEE 6000 mm
Clear height-Lean to 0 mm

EARTHWORK
Earthwork in excavation in all types of soils like murum, clay, sand, stone pads or any other
type of soil, providing shoring, pumping or bailing out the water preparing bed for
foundation, back filling with s cu.m 1,053
layers within the premises, watering and consolidation all as directed ( foundation depth 1.5-
2.5m).
Excavation for Plinth beams
Filling in plinth, under pavement, foundations and trenches etc.,as directed with selected
murum brought from outside/(or cu.m 611
consolidation etc.volume
Providing dry Rubble soling of cu.m 936.96
chips and spall, watering consolidating etc.
PCC, CONCRETE AND STEEL
Providing and casting in Situ cement concrete M15 of trap / granite /quartzite / gnessis
metal for steps including centering , formwork , 60
is to be provided and curincu.m
sand .
Providing and laying in situ cement concrete M-25 for R.C.C. work in foundations, grillage
,footings of R.C.C. columns and steel stanchions, plinth beams , stub columns Chajja , lintel
beam , sill beam etc. including bailing out water, formwork ,cover blocks compaction and
curing roughening the surface ifcu.m 210
and structural steel) complete, With fully automatic micro processor based PLC with SCADA
enabled reversible drum type concrete mixer.. With natural sand/crushed sand
Fixing in position foundation boqty 50
of 12-15mm with non spring grout material
Providing and laying in situ ce cu.m 0
thickness 150mm
Providing, cutting, fabricating & erectiong in position steel reinforcement as per
specifications, drawings and requirements at all heights and locations including
handling,transporting, steel complete for all R.C. C. works. Contractor to use their own 28
swg G.I. binding wires, spacer MT 18.23
shown on drawings plus authorised overlaps, spacers and chairs. H.Y.S.D. Bars Fe 500 TMT
BRICKWORK/MASONARY/PLASTERING
Providing first class Burnt Brick 230mm thk masonry with conventional/ I.S. type bricks in
cement mortar 1:6 in plinth andsqm 540
with cement mortar 1:3 on exposed face and watering Complete.
Providing and applying internal cement plaster in thickness of 12 mm to 15mm in C.M. 1:5 to
all concrete surfaces of slabs, beams at all levels including scaffolding,leads, curing
complete proper line and level.PCM 1:4, 20mm
thick (average) in two coats wi sqm 1080
to specification including necessary scaffolding, curing and hacking to the surface etc.,
complete. It includes making grooves, patties,plastering to precast concrete window sills,RCC
cornices curing,cleaning, etc.
TRIMIX
Providing, machine mixing and laying of vacuum dewatered concrete of grade M 20 , 125mm
of trap metal for cement concreas per deincludingdewateristeel form
work, compaction, panels as specifiedand as per reco
of equipment/machines, cutting groovesexpansion
i
of joint about 1/3rd depth of co and 8mm wide, filling grooves with
polysulphide sealant of approve make, power floating and broom fin
smooth as specified / instructed, completeto the
entire satisfaction of the consultant

PCC M10 DESIGN CODE


CONCRETE M25 LOADINGS
STEEL FE 415 EARTHQUAKE

DOORS
General Notes:
Please refer sketch for more detail.
Quantities calcualted are based on reactions recived from steel bldg design.
Any change in steel buildings will affect the RCC design.
estimate doesnt include buyout items.
Sheeting on high blockwalls is considered for all exteriors walls as per the
Date 13-2-17 Designed By AKS

STRUCTUDETAILS
Main FraTapered Pinned Base
Interior Straight Pinned Base
Crane Column N/A
1:10
Near End Wall Expandable
Expandable
Left Side wall Non Expandable
Right Side Wall Non Expandable

MAIN DETAILS

e pads or any other

oundation depth 1.5-

cu.m 45
ed with selected

tzite / gnessis

dations, grillage
umns Chajja , lintel
compaction and

ed PLC with SCADA

use their own 28

. Bars Fe 500 TMT


.S. type bricks in

15mm in C.M. 1:5 to


ads, curing

e surface etc.,
ete window sills,RCC

grade M 20 , 125mm thick

of manufacturer

sqm 4,074
floating and broom finishing or finishing

GRADES AND DESIGN CODE


DESIGN CODE IS456:2000 PLAIN AND REINFORCED CONCRETE ( IV REVISION)
LOADINGS IS 875(I-V):1987- CODE OF PRACTICE FOR DESIGN LOADS
EARTHQUAKE IS1893:2002 CRITERIA FOR EARTHQUAKE RESISTANT DESIGN OF ST
DOORS, AND LOUVERS
WINDOWS ROLLING SHUTTER

ors walls as per the drawing.(refer drawings)


CheckedSPS

Unit Qty
IV REVISION)
DESIGN LOADS
RESISTANT DESIGN OF STRUCTURE

ROLLING SHUTTER