Specialised Fire Resistant


Door Hardware
protecting against
smoke and fire
Fire and smoke protection measures are an essential, life-
saving precaution in a building. Whats more, they protect
the property from the devastating consequences of the fire
itself, and the damaging effects of hot and cold smoke.
So its essential to get the product selection right, every time.

Lorient has a respected reputation for We embrace the highest management


designing and manufacturing a wide range standards too, and hold both
of products for fire and smoke containment. BS EN ISO 9001:2008 and
Products are also designed with acoustic, BS EN ISO 14001:2004 certificates for
thermal and weather containment in mind, our quality and environmental management
as well as accessibility so you can be systems. Achieving ISO 14001 is just one
assured that a Lorient system provides an part of our ongoing commitment to operate
integrated, cost-effective solution. in a sustainable way: many initiatives are
planned and already underway to reduce
With 35 years experience and accumulated
materials and energy usage, as well
knowledge, we pride ourselves on offering
as waste.
ground-breaking innovations, underpinned by
technical excellence and exceptional quality. In addition to our UK and Europe head office,
Our dedicated R&D centre not only generates we have a number of operations around
successful product developments for Lorient; the world; in North America, Hong Kong,
it also allows us to work in partnership with Singapore and Australia. Furthermore, we
customers to develop and test their own have strong links in India and the Middle
products too. Our indicative fire test furnace East, which means that were able to deliver
is particularly popular, giving customers real the right solutions locally to our customers
insight into their own products performance throughout the world. By keeping abreast
and helping to save substantial testing costs. of technical developments and changes to
codes, regulations and standards across
Always keen to keep raising the bar, we are
the continents, we can ensure were always
committed to gaining third party certification
providing the highest level of expertise.
for our products wherever a suitable scheme
From advice to testing, new product
exists. Many products hold CERTIFIRE
development to manufacture we work best
certification, and we also hold approvals
in partnership with you.
from both the BBA and IFC.

Contents

Fire and Smoke Life Threatening Forces 2

Product Selector 4

Edge Protector 5

Letterplates 69

Wide Angle Viewer 10

Intumescent Protection Kits (locks, latches and hinges) 11

Concealed Door Closer Protection Kits 12

Additional Information 13

Comprehensive Support 14 15

02/14
Fire and Smoke Life Threatening Forces

On average 311 people are killed and 11,100 are injured* in fires each year in the
UK alone. Many of the casualties are attributable to breathing the toxic products of
combustion from a remote fire.
Fire and smoke also cause extensive damage to building fabric and contents. 2.52
billion* per annum is the estimated total of fire-related losses. The majority of these
deaths, injuries and losses occur in buildings where fire and smoke protection measures
have been inadequate.

Design Needs and and smoke resistant compartments are Relevant Standards
Regulatory Requirements maintained. Our fire and smoke seals can
There are several British Standards which
be fitted into fire rated doors; our glazing
When fire breaks out in a building the relate to the products and solutions featured
products can be fitted into doors, screens
threat is twofold. Firstly, there is the fire in this brochure. They include:
or fire rated partitions; our air transfer grilles
itself and the hot smoke generated in the
can be installed into doors, walls and ducts. BS 476 Pt. 22: 1987: Methods for
immediate vicinity. Secondly, there is cold
determination of the fire resistance of
smoke which will spread rapidly through Fire and smoke protection products must
non-loadbearing elements of construction;
the building, threatening people and be tested to prove their performance
property some distance from the fire. and indeed, separate tests are required BS 476 Pt.31.1: 1983: Methods for
The Building Regulations take both these for fire and smoke. Our products are all measuring smoke penetration through
threats into account, and supporting extensively tested, and our test reports are doorset and shutter assemblies;
documents give criteria for how they freely available on request. Just call our BS 9999: 2008: Code of practice for fire
can be managed. Details can be found in Technical Services team on 01626 834252. safety in the design, management and use
Approved Document B (England & Wales), of buildings.
Technical Booklet E (N Ireland), and Fire Resistant Door Hardware
Technical Handbook Section 2 (Scotland). Fire rated doors often need additional items
The Regulations require large buildings of hardware installed to make them work
to be divided into smaller fire and smoke locks, letterplates, door closers, security
resistant compartments, to reduce the viewers as well as products to protect
risk of damage to the building as a whole them from damage. This brochure shows
and also to save lives in the case of a fire. our products that can safely be installed
Building a fire resistant wall or floor to into fire rated doors, without compromising Use of symbols
make a compartment is relatively simple. the fire and smoke integrity of the doorset.
However, building design becomes much Featured products include: indicates that the product
more complex when the compartments detail shown provides protection
a range of door hardware items which
need to be linked in some way essential against fire
offer security and protection against
to make the building usable. Every time an smoke and fire; indicates that the product
aperture is cut into one of the compartment
universal intumescent protection kits detail shown provides protection
boundaries (for example, to install a door against cold smoke
available for door closers and other
in a fire resistant wall, or to pass ductwork
ironmongery items;
through a wall or ceiling) the aperture indicates that the product featured
must be filled with something that will durable door leaf edge protectors with provides acoustic benefits
preserve the fire and smoke integrity of the built-in acoustic, smoke and fire seals.
indicates in minutes the fire
compartment. Thats the role of Lorients
protection provided by the product
products to work with the surrounding
elements of the building to ensure the fire

* Source: Communities and Local Government Website 2012.

2 SPECIALISED FIRE RESISTANT DOOR HARDWARE


Specialised Fire Resistant Door Hardware

product solutions

SPECIALISED FIRE RESISTANT DOOR HARDWARE 3


Product Selector

Weve provided guidance throughout the product range for


the different types of door hardware protection, along with
the duration of protection achieved.

A
C
C

B C
C
D

C C

External or Apartment Entry /


Internal Door Leaf Hotel Door Leaf
A Door Closer Protection Kits C Hinge Protection Kits
30 and 60 minutes fire protection (see page 12) 30 and 60 minutes fire protection (see page 11)

B Edge Protector D Wide Angle Viewer


30 and 60 minutes fire and smoke protection (see page 5) 30 minutes fire and smoke protection (see page 10)

C Hinge Protection Kits E Lock and Latch Protection Kits


30 and 60 minutes fire protection (see page 11) 30 and 60 minutes fire and smoke protection (see page 11)

F Letterplates
Up to 60 minutes fire and smoke protection plus security features
(see pages 6 9)

4 SPECIALISED FIRE RESISTANT DOOR HARDWARE


Edge Protector

Some doors suffer severe damage to the leading edge due to


heavy volumes of pedestrian and wheeled traffic. New test evidence
means that our Edge Protector now incorporates the innovative
DS seal. Together they offer superior combined protection against
damage, fire, smoke, sound and germs.

Key benefits
Protects door edges against impact damage, to retain
the doors appearance.
TECHNICAL DETAILS
Cost effective it reduces the need to replace the door:
easy to fit to new or existing doors.
Door thickness: nom. 44mm and 54mm
Fire resistance provided for 30 to 60 minute applications: Also incorporates a margin for inevitable
successfully fire and smoke tested to BS 476 Pt. 22: 1987 variations in door thicknesses up to 62mm
and BS 476 Pt. 31.1: 1983.
Superior acoustic performance is provided by the unique Standard leg lengths: from 32mm to 50mm
dual fins on the DS seal meeting the requirements of
Max length: 2.4m
Approved Document E.
Low frictional elastomeric fins of the DS seal enable ease Edges: radius or square
of door operation meeting the requirements of Approved double swing type also available
Document M.
Use with: laminated softwood or hardwood, flaxboard or
Hygienic easy to wipe clean.
particleboard or solid homogeneous particleboard doors
Low maintenance.
Our Door Edge Protectors are manufactured from heavy duty, For pairs of doors, one door leaf should be fitted with a fire seal
impact resistant vinyl material, with a textured finish to reduce only Edge Protector and the other should be fitted with a DS seal
scuff marks. Available in two finishes, Hessian (textured) and Edge Protector. Brush type fire and smoke seals are also available.
Falmouth (smoother with light stippling). Matching items can be supplied, including push plates, kick plates
and door panels.

32mm 32mm
44mm
44mm

Door leaf

12mm 12mm

RJ 4432S RJ 4432R

32mm 32mm

LP1504DS acoustic,
smoke and fire seal
54mm
54mm

DS door Edge Protector


Falmouth finish

12mm 12mm Patented


RJ 5432S RJ 5432R

SPECIALISED FIRE RESISTANT DOOR HARDWARE 5


Letterplates
Doors from common passageways to flats, apartments
and offices are frequently required to be fire and smoke
resistant. They may also need to be fitted with a letterplate.
Fitting a normal letterplate assembly would completely
negate the fire and smoke resisting properties of a door.
We supply two fire and smoke resistant letterplate models.
Our integrated fire/security letterplate can be fitted with a
range of optional security devices.

Lorient fire and smoke resistant letterplates:


provide protection against fire and smoke at all temperatures
when fitted to previously tested door sets;
provide protection against cold smoke in line with the
requirements of BS 9999: 2008 and Approved Document B
to the Building Regulations.

6 SPECIALISED FIRE RESISTANT DOOR HARDWARE


Firemaster Fire and Smoke
Resistant Letterplate
RJS 29063

271mm
285mm
70mm
55mm

254 x 36mm Sleeve Aperture 5mm

304mm Overall Size

High Performance Fire, Smoke


and Security Letterplate
RJ 8042F
RJ 8042S
RJ 8047F
RJ 8047S
RJ 8052F
RJ 8052S

267mm
290mm
80mm
60mm

250 x 40mm Sleeve Aperture 8mm

312mm Overall Size

SPECIALISED FIRE RESISTANT DOOR HARDWARE 7


Firemaster Fire and Smoke
Resistant Letterplate
TECHNICAL DETAILS
CF219

Max/min door thickness: 40mm 70mm


This letterplate assembly has been tested in accordance with
External height: 70mm
the principles of BS 476: Pt. 20/22: 1987 and provides in excess
of 30 minutes fire resistance.
External width: 304mm
Like other letterplate designs in our range, the intumescent liner
is telescopic, making it suitable for different thicknesses of door. Door aperture size: 285mm x 55mm

Key benefits Finishes: silver anodised, polished silver or polished gold


Robust aluminium construction.
Tested with positive pressure and can be located in any area
of the door.
Nylon brush seals fitted to prevent vision through the letterplate AcousticPerformance
Acoustic Performance
and provided draught proofing.
Security cowl is available to prevent vision through the letterplate Under
Undertest
test conditions
conditions itit has
has been demonstrated that the
when open, and to inhibit manipulation of locks and bolts. Firemaster
Firemasterletterplate
letterplatedoes
does notnot cause
cause any
any signicant
significant reduction
reduction to the
to the overall overallperformance
acoustic acoustic performance
of the solidofcore
the solid
fire door
core re door to which it is tted. For more information please
to which it is fitted. For more detailed information please
contact our Technical Services team on 01626 834252.
contact our Technical Services team on 01626 834252.

334mm
73mm

303mm
mm
60

Security Cowl RJ 290X063C

Letterplate manufactured by Paddock Fabrications Ltd.


High Performance Fire, Smoke
and Security Letterplate
Optional Security Features
CF255
These items may be fitted at the same time as the letterplate
or at a later date.
This high performance letterplate assembly has been tested
in accordance with BS 476: Pt. 22 1987 and provides more Security Cowl
than 60 minutes fire protection. Prevents people seeing through an open letterplate.
The letterplate assembly is internally sealed so that the unit will Stops people trying to manipulate locks and bolts through
not compromise the smoke integrity of the door when tested in a letterbox.
accordance with BS 476: Pt. 31: 1: 1983. It can also be supplied
Reduces the risk of occupants being attacked through
with a range of optional security devices. Several models of this
a letterbox aperture.
letterplate are available to suit different thicknesses of door.

Security Latch
TECHNICAL DETAILS Locks the inner flap.

Max/min door thickness: 42mm 47mm: RJ 8042F or RJ 8042S Post-box


47mm 52mm: RJ 8047F or RJ 8047S This item is constructed from steel with welded seams.
52mm 57mm: RJ 8052F or RJ 8052S
note: Suffix F indicates fire protection Collects the post and keeps it secure.
Suffix S indicates fire and smoke protection Prevents damage from flammable or harmful items posted
through a letterplate.
External height: 80mm

External width: 312mm

Door aperture size: 270mm x 60mm

Letter flaps: For 30 mins, silver or gold anodised. For 60 mins,


brushed stainless, brass or *powder coated steel; other finishes are
also available. * For internal use only (applicable to powder coated steel).
fixing area

320mm
410mm including screw
78mm
mm
57

322m
2m

m
12

Security Cowl LP10 Internal security Latch LP11 Lockable Post-box LP12

Manufactured by Royde & Tucker Ltd.

SPECIALISED FIRE RESISTANT DOOR HARDWARE 9


Wide Angle Viewer

A one-way viewer which allows occupants to see and identify


callers. The viewer is supplied with an integral intumescent liner.
Tests prove the viewer can be fitted to 30 minute fire resistant
doors without compromising fire safety.

Key benefits
Allows callers to be seen and identified without opening the door.
Projects an image of the caller onto an etched glass screen
which can be easily viewed from a convenient distance. Its not
necessary to have the eye so close to the viewer that there is a
risk of penetration from sharp objects.
Allows occupants to see out but does not allow callers to see in.
Provides fire resistance of 30 minutes when fitted to full size door
assemblies and tested in accordance with BS 476: Pt. 22: 1987.
Is available in silver, white, gold, black or bronze.
A wide viewing angle of 160.

Integral Lorient
intumescent liner
37mm

Viewer
24mm 45mm
Etched glass screen,
38mm diameter on
internal face

RJ 3745 External aspect Internal aspect

10 SPECIALISED FIRE RESISTANT DOOR HARDWARE


Intumescent Protection Kits Hinge Protection Kits
We supply intumescent protection kits for commonly specified hinges.
These kits provide fire resistance of 30 minutes or 60 minutes
when fitted to full size door assemblies and tested in accordance
with BS EN 1363: Pt. 1: 1999.

Lock and Latch Protection Kits


All door furniture must be fitted in a way which ensures
the fire resisting properties of a door arent compromised. If the lock or latch of a fire resistant door is unprotected, it inevitably
In many instances its advised that ironmongery is bedded reduces the doors fire protection performance. Lorient provides a
in intumescent mastic or paste. universal lock kit which enables family groups of mortise locks to be
incorporated in fire resistant door leaves, as well as a lock kit which
A quicker, easier, cleaner and more accurate solution is to
is available to suit larger lock sizes.
use shaped pads of intumescent material. We offer a range
of kits designed for use with: These kits provide fire resistance of 30 minutes or 60 minutes
when fitted to full size door assemblies and tested in accordance
hinges;
with BS EN 1363: Pt. 1: 1999.
locks and latches;
concealed hydraulic door closers (see page 12).

Door leaf

Lorient
intumescent
lock jacket
Lorient
intumescent
lock and
latch plate Lock

Integral Lorient
intumescent liner

Hinge

Hinge protection kit Lock and latch protection kit

SPECIALISED FIRE RESISTANT DOOR HARDWARE 11


Concealed Door Closer
Protection Kits

Partition wall
Hydraulic closers concealed in the door leaf are increasingly
popular but they must not be fitted to fire resistant doors without
appropriate protective measures being taken. This is because:
they require a large portion of the door to be cut away which
immediately reduces fire resistance; Frame head

many models contain flammable hydraulic oil;


Lorient
the aluminium housings are likely to melt in intense heat intumescent
liner
leading to a breach;
they are made from materials which are very good heat
conductors and take up much of the available door leaf thickness.
Door closer
head rail
Our intumescent protection kits overcome these problems.
They consist of a thin, high performance intumescent sheet,
pre-cut and scored so that they can be easily fitted around door
closers. The kits are self-adhesive for straightforward installation. Door closer

When tested in accordance with BS 476: Pt. 20/22: 1987 it was


shown that our closer protection kits can provide up to 60 minutes
protection, even on 44mm thickness door leaves.
The low pressure intumescent action ensures the door leaf is not
Lorient
split. Insulation against heat transfer is provided as soon as the intumescent
liner
intumescent material is activated.

Door leaf

12 SPECIALISED FIRE RESISTANT DOOR HARDWARE


additional information

Technical References Handling and Storage


Lorient is quality assured under the disciplines No special precautions are required when handling our specialised fire
ISO
of BS EN ISO 9001:2008. 9001 resistant door hardware products but they should always be treated
Quality
Management with care. Our products should be stored in a clean, dry, dust-free
Accreditation to this standard is a guarantee
area away from heat and at a storage temperature no less than 5C.
that we conduct our business to the complete BS EN ISO 9001:2008
Certificate No. Q6104
satisfaction of our customers with regard to Maintenance
design solutions, manufacturing consistency
Periodic inspection/cleaning is recommended for all products.
and management procedures.
Worn or damaged products should be replaced without delay.
In addition, this internationally recognised standard for quality
management generates customer confidence and eliminates the risk Trade Associations
of poor performance. Regular audits of our company procedures are Lorient is a founder member of the Intumescent Fire Seals
undertaken by qualified BSI staff to ensure ongoing compliance with Association (IFSA) and a member of the Association of Interior
all aspects of the standard. Specialists (AIS).

Lorient has attained BS EN ISO 14001:2004 ISO


14001
accreditation for environmental management, Environmental
Management
making us the first seal manufacturer to Founder Member of the
Intumescent Fire Seals Association of
have achieved this important award. This BS EN ISO 14001:2004 Association Interior Specialists

internationally recognised standard represents Certificate No. EMS 541906


Lorient is also a member of the British Woodworking Federation
that we have demonstrated our commitment
(BWF) (Associate); the Architectural and Specialist Door
to responsible environmental behaviour, including prevention of
Manufacturers Association (ASDMA); the Guild of Architectural
pollution, control and reduction of waste, and ongoing monitoring
Ironmongers (GAI); and is also an Approved Supplier to the
and improvement of its environmental performance. Achieving
BWF CERTIFIRE Fire Door and Doorset Scheme.
ISO 14001 is just one part of our ongoing commitment to operate
in a sustainable way.
Lorients products can also make an important contribution to
Architectural and
sustainability within a buildings construction: our acoustic, smoke Specialist Door
Manufacturers
Association
and fire seals can additionally provide thermal containment benefits,
aiding efficient energy management in a building.
Intellectual Property
2014 Lorient Polyproducts Ltd this brochure is protected by copyright and neither the
drawings nor the text may be reproduced or transmitted in any form without prior consent
from Lorient. Lorient products described in this brochure are protected by patents and design
registrations in Great Britain and other countries.
We are committed to continually enhancing and improving our product range. We reserve
the right to change product specifications from time to time without prior notice. E&OE.

SPECIALISED FIRE RESISTANT DOOR HARDWARE 13


Continuing Professional Development Seminars
We offer three fully-accredited CPD seminars. Impartially
presented by knowledgeable speakers, the seminars are
structured to be technically informative, and give practical advice.

Performance Door Design: The Role and Performance The Regulatory Reform (Fire Safety)
The Basics of Sound Reduction of Fire and Smoke-Resisting Order 2005 and its implications
Door Assemblies for fire doors
Effective acoustic containment helps to The importance of fire and smoke resisting The RRO consolidated 70 pieces of
improve the quality of the built environment, door assemblies is illustrated by the 311 legislation; shifted responsibility for fire
preserving privacy as well as excluding annual deaths in fire tragedies in the UK safety management; abolished the Fire
unwanted noise. With changing regulations, alone. Apart from the human toll, property Safety Certificate; established the Fire Risk
its essential to be informed of the relevant losses each year approach 2.52 billion. Assessment and created major change in
requirements and the implications for legal liability.
Our fire and smoke containment CPD
door assemblies.
seminar covers: Our RRO CPD seminar covers:
Our acoustic CPD seminar covers: hard facts concerning deaths, injuries an overview of the RRO;
the nature of sound, examining and property damage caused by fire
airborne transmission of sound; and smoke; product solutions;

regulatory requirements and regulatory requirements for fire and the dangers of fire and smoke;
British Standards that relate smoke resisting door assemblies;
the importance of fire doors including
to acoustic performance; the nature and behaviour of smoke; installation and maintenance.
test procedures and interpretation effective design of door assemblies
of test reports; Our CPD materials have been independently
for smoke containment, including the
verified and certified by the RIBA as CPD
effective design of door assemblies threshold gap;
approved. A certificate for 1 hours CPD
for acoustic performance, including design conflicts between fire containment, will be provided, which contributes to
door construction and the influence smoke containment, durability and ease Continuing Professional Development
of sealing systems; of operation of the door; requirements.
design conflicts between acoustic
independent accreditation. If youre interested in booking either
performance, durability and ease
of operation of the door; seminar, please contact our Marketing
department or e-mail cpd@lorientuk.com.
independent accreditation.

14 SPECIALISED FIRE RESISTANT DOOR HARDWARE


We continue to lead the way in research and development: As a company
we have nearly 35 years experience, so our experts are well equipped to listen,
help and advise you on your acoustic, smoke and fire containment needs.

comprehensive support

Technical Services Customisation Testing Services


Were happy to provide specialist advice If you have a particular requirement Lorients Testing & Technical Services
on acoustic, smoke and fire protection which isnt covered by the applications centre offers a variety of specialist testing
for refurbishment and new build projects. in this brochure, we may be able to supply services for manufacturers and designers
If you need assistance, you can call our an existing non-standard item, or even of assemblies including doorsets, windows,
Technical Services team. develop a customised solution for you. glazing systems and door hardware to
name but a few. Whether youre
Alternatively, we can arrange a site visit
investigating new materials, or developing
to get a clearer idea of your needs and how
new or existing products, right through
we can help you. We also provide copies
to durability testing and benchmarking
of test reports and samples where needed
performance our team of experts will
and can give guidance on how best to meet
support you throughout the process.
Building Regulations and Standards.

Call our Technical Services team on


01626 834252
www.lorientuk.com

SPECIALISED FIRE RESISTANT DOOR HARDWARE 15


www.lorientgroup.com UK and Europe Hong Kong Dubai
Tel: +44 (0) 1626 834252 Tel: +852 2505 0328 Tel: +9714 883 7206
LorientPolyproducts Fax: +44 (0) 1626 833166 Fax: +852 2505 0332 Fax: +9714 883 7207
email: mktg@lorientuk.com email: sales@lorienthk.com email: sales@lorientgulf.ae
@LorientUK
USA Singapore Australia
Lorient +61 (02) 99076221
Tel: +1 859 252 7441 Tel: +65 6270 1279 Tel:
lorientuk Fax: +1 859 381 1241 email:sales@lorient.com.sg email: sales@lorient.com.au
inquiries@lorientna.com

Lorient Polyproducts Ltd


Endeavour House
Fairfax Road
Heathfield Ind Estate
Newton Abbot
Devon TQ12 6UD UK

You might also like