You are on page 1of 3

For S-CONCRETE I-shapes, Zone A is always associated with the I node and Zone B is always associated

with the J node for wall integration line (WIL) results in S-FRAME. Regardless of the specified orientation
in S-CONCRETE (0, 90, 180, or 270), the wall integration line results will be exported initially assuming
the above configuration. In other words, if the J node is in compression in S-FRAME, Zone B will be in
compression in S-CONCRETE regardless of the orientation at the end of the transfer process.

For S-CONCRETE I-Shapes, wall integration line (WIL) results will be exported in the following manner for
various orientations. For C-Shapes, T-Shapes, and L-Shapes, WIL results will also be exported in the same
manner to the sectional loads spreadsheet.

S-FRAME S-CONCRETE
WIL Results Sectional Forces
Fx -Vy

Fy -Vz

Fz N

Mx -My

My Mz

Mz T

1
S-FRAME S-CONCRETE
WIL Results Sectional Forces
Fx -Vz

Fy Vy

Fz N

Mx Mz

My My

Mz T

S-FRAME S-CONCRETE
WIL Results Sectional Forces
Fx Vy

Fy Vz

Fz N

Mx My

My -Mz

Mz T

S-FRAME S-CONCRETE
WIL Results Sectional Forces
Fx Vz

Fy -Vy

Fz N

Mx -Mz

My -My

Mz T

2
For S-CONCRETE beams or columns, wall integration line (WIL) results will be exported in the following
manner.

S-FRAME S-CONCRETE
WIL Results Sectional Forces
Fx -Vz

Fy Vy

Fz N

Mx Mz

My My

Mz T