You are on page 1of 84

VQ-A.

qxd

09.2.26 2:35 PM

Page 1

5 Port Solenoid Valve


Metal Seal / Rubber Seal
[Option]

RoHS
compliant

Power saving

Standard: 0.4 W

60% compared to existing model)


High-pressure (1 MPa, Metal seal): 0.95 W
(Reduced by

Series VQ1000/2000
CAT.ES11-100A

VQ-A.qxd

09.2.26 2:36 PM

Page 2

5 Port Solenoid Valve Series VQ


Thin compact design
with high flow capacity

Space-saving profile
All pilot valves are compactly mounted on one side.
The space-saving design of mounting all fittings on
one side permits mounting in three directions.

The non-bias, one-clamp


structure permits easy valve
replacement.

Flow-rate characteristics

Model

Manifold
pitch
(mm)

Metal seal

Rubber seal

C [dm3/(sbar)]

C [dm3/(sbar)]

Applicable
cylinder
bore size

VQ1000

10.5

0.72

1.0

Up to 50

VQ2000

16

2.6

3.2

Up to 80

Flow-rate characteristics: 4/2 5/3 (A/B R1/R2)

A wide variety of optinal parts


Regulator unit

Built-in one-touch fittings


for easy piping

Slide locking type (Manual)

This regulator adjusts the SUP pressure of a manifold


and reduces the supply pressure from the
D-side SUP port.

Slide locking type manual


override provided

The photo does not show


an actual use example.

Locking type (Manual)


Ejector unit
It is possible to mount an ejector on the
manifold together with the solenoid valve.
Reduced wiring and space saving.

Blanking plate
assembly

Direct EXH outlet


with built-in silencer

U sid

Manual override cannot be pushed by sliding


the switch, to prevent malfunction.
Bore 1.7

OFF

Port plug

ON

D sid

Individual SUP spacer


Individual EXH spacer

B side
Manual override
(Green)

A side
Manual override
(Orange)

DIN rail
Elbow fitting assembly
bottom ported

Dual flow fitting


This fitting can double the flow rate
by consolidating the outputs of the
valves of two stations.
It is used for operating cylinders
with large bore size.

VQ1000

Elbow fitting assembly


top ported

VQ1000

Plug-in

Base Mounted

Series

P. 7
Series

VQ2000

(F/L
kit
only)

Rubber seal

VQ101

P. 15

VQ200

2.6

2.0

3.2

2.2

(F/L
kit
only)

Rubber seal

VQ201

P. 15

Slide locking type (Manual)

Locking type (Manual)

Locking type (Tool required)

Non-locking push type (Tool required)

50/60 50/60
Hz Hz

Manual override

M-type plug connector

0.65

12 VDC 100 VAC 200 VAC


24 VDC 110 VAC 220 VAC

Electrical entry

L-type plug connector

1.0

Voltage

Grommet

0.72

Metal seal

P. 11

VQ100

Pressure center

3-position
(Closed center)

0.72

Metal seal

Exhaust center

Double
Single

4/2 5/3
(A/B R1/R2)

Closed center

C [dm /(sbar)]

Type of actuation
Double

Single

Sonic
conductance

Plug-in

Valve Specifications

VQ-A.qxd

09.2.26 2:36 PM

Page 3

Series VQ1000

Series VQ2000

A variety of common wiring methods are standardized.

P kit
(Flat ribbon cable)

kit
(D-sub connector)
Number of pins: 15/25

Top entry

Number of pins: 10/16/20/26

Side entry

G kit
(Flat ribbon

cable with
terminal block)
Number of pins: 20

Top entry

kit
(Terminal block
box)

Side entry

kit
(Lead wire)

kit
(PC Wiring System compliant
Flat ribbon cable)
Number of pins: 20

Top entry

S kit
(Serial

Side entry

M kit
(Circular

transmission)

connector)

(VQ2000 only)

Model

Dual 3-port valves, 4 positions

A side

B side

Rubber seal only




Two 3-port valves built into one body.


 The 3-port valves on the A and B sides can operate independently.
 When used as 3 port valves, only half the number of stations is
required.
 Can also be used as a 4-position, 5-port type valve.
Exhaust center :
:
Pressure center :
:

VQ1A01
VQ2A01
VQ1B01
VQ2B01

VQ1A01
VQ2A01

N.C.
valve

N.C.
valve

VQ1B01
VQ2B01

N.O.
valve

N.O.
valve

2
(B)

1
(P)

N.C.
valve

N.O.
valve

5
(R1)

3
(R2)
2
(B)

1
(P)

3
(R2)

Double check block (Separated)

Ejector unit

Regulator unit

Plug for cylinder port

Dual flow fitting

Elbow fitting for cylinder port

Silencer for EXH port

Built-in silencer

DIN rail mounting

Back pressure check valve

Name plate

SUP/EXH block plate

Individual SUP/EXH spacer

Options
Blanking plate

Special wiring specifications

Inch-size one-touch fittings

Negative COM specifications

D-sub connector 15P

Flat ribbon cable 10P/16P/20P

P. 55

5
(R1)

3
(R2)

Except
L kit

P. 55
Except
S/G
kit

1
(P)

4
(A)

VQ1C01
VQ2C01

Semi-standard

Except
S/G
kit

5
(R1)

2
(B)

4
(A)

R1 A P B R2

External pilot

JIS symbol
4
(A)

P. 65
Except
L kit

P. 71

VQ-A.qxd

09.2.26 2:36 PM

Page 4

Series VQ /Base

Mounted: Variations
Manifold Variations
Plug-in
Series VQ1000

F
kit

P
kit

J
kit

G
kit

T
kit

Series VQ2000

D-sub connector
Conforming to with MIL
D-sub connector

P. 17

P. 17

P. 21

P. 21

P. 29

P. 29

Flat ribbon cable


(26/20/16/10 pins)
Conforming to MIL flat
ribbon cable connector

Flat ribbon cable


(20 pins)
Conforming to MIL flat ribbon
cable connector
PC Wiring System compatible

Flat ribbon cable


with terminal
block
Conforming to MIL flat ribbon
cable connector
Applicable to OMRONs serial
transmission unit
PC Wiring System compatible

Terminal block
box
(Terminal block)
Terminal block is
compactly arranged on
one side.

P. 33

IP65 enclosure
compatible

P. 33

P. 37

IP65 enclosure
compatible

P. 37

Lead wire
Direct electrical entry type
3
4

kit

1
2
4
3
2
3

2
1

VQ-A.qxd

09.2.26 2:36 PM

Page 5

Manifold Variations
Plug-in
Series VQ1000

Series VQ2000

Gateway-type
serial
transmission
system
Serial unit: EX510
IP20 enclosure
compliant

S
kit

Integrated-type
serial
transmission
system (for
Output)

P. 41

IP20 enclosure
compliant

P. 41

P. 45

IP20 enclosure
compliant

P. 45

Serial unit:
EX120/123/124

Dust-protected (-XP)

P. 45

Dust-tight,
Water-jet-proof (-W)
IP65 enclosure compliant

P. 45

IP65 enclosure
compliant

P. 49

W type only

P. 51

Integrated-type
serial
transmission
system (for I/O)
Serial unit: EX240

M
kit

Circular
connector
IP65
(Dust-tight, Water-jet-proof)

VQ-A.qxd

09.2.26 2:36 PM

Page 6

Cylinder Speed Chart


This chart is provided as guidelines only.
For performance under various conditions, use SMC's Model
Selection Program before making a judgment.

Bore size

Series

Average
speed
(mm/s)

VQ1101
Port size:
6 one-touch fitting

VQ2101
Port size:
8 one-touch fitting

10

16

Series MB, CA2


Pressure 0.5 MPa
Load factor 50%
Stroke 500 mm

Series CM2
Pressure 0.5 MPa
Load factor 50%
Stroke 300 mm

Series CJ2
Pressure 0.5 MPa
Load factor 50%
Stroke 60 mm
20

25

32

40

40

800
700
600
500
400
300
200
100
0

50

63

80

100

Perpendicular,
upward actuation
Horizontal actuation

800
700
600
500
400
300
200
100
0

It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder,
and its needle valve with being fully open.
The average velocity of the cylinder is what the stroke is divided by the total stroke time.
Load factor: ((Load mass x 9.8)/Theoretical force) x 100%

Conditions
Series

Conditions
Tube bore x Length

VQ1101

Series CM2

Series MB, CA2

T0604 (O.D. 6/I.D. 4) x 1 m

Speed controller

AS3001F-06

Silencer

AN200-KM8

Tube bore x Length

VQ2101

Series CJ2

T0806 (O.D. 8/I.D. 6) x 1 m

Speed controller

AS3001F-08

Silencer

AN200-KM10

09.3.3 11:32 AM

Page 7

VQ1000/2000
T kit (Terminal block box)
VQ1000/2000
L kit (Lead wire)

P. 33

3
4
1
2
4
3
2
3

P. 37

VQ1000/2000
S kit (Serial transmission) EX510
VQ1000/2000
S kit (Serial transmission) EX120/123/124
VQ1000/2000
S kit (Serial transmission) EX240
VQ2000
M kit (Circular connector)
VQ2000 Sub-plate Single Unit
VQ1000/2000 Semi-standard
VQ1000/2000 Construction
VQ1000/2000 Exploded View of Manifold
VQ1000/2000 Manifold Optional Parts
Safety Instructions
VQ1000/2000 Specific Product Precautions

P. 41

P. 45

P. 49

P. 51
P. 54
P. 55
P. 59
P. 61
P. 65
Back page 1
Back page 3
6

P kit
J kit
G kit
T kit
L kit
S kit

P. 29

M kit

VQ1000/2000
G kit (Flat ribbon cable with terminal block)

P. 25

Sub-plate
Single Unit

VQ1000/2000
J kit (Flat ribbon cable)

P. 21

Semistandard

VQ1000/2000
P kit (Flat ribbon cable)

P. 17

Construction

VQ1000/2000
F kit (D-sub connector)

P. 1
P. 3
P. 5
P. 7
P. 11
P. 15

Exploded
View of
Manifold

Features
Variations
Cylinder Speed Chart
VQ1000 How to Order, Manifold Options
VQ2000 How to Order, Manifold Options
VQ1000/2000 Model, Standard/Manifold Specifications

F kit

I N D E X

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

VQ-A.qxd

Plug-in Unit
Base Mounted

Series VQ1000

[Option]
Note) For CE compliant
models, DC-type only.

How to Order Manifold

VV5Q 1 1 08 C6 F U1
CE compliant

Series
1

Nil

VQ1000

CE compliant

Note) For CE compliant models, DC-type only.

Manifold
1

Option

Plug-in unit

Symbol
Nil

Stations
01

2
B Note 2)
D
D0
D Note 7)
G1 Note 3)
G2 Note 3)
G3 Note 3)
J Note 4)
K Note 5)
N
R Note 6)
S

1 station

Kit type
The number of max. stations
differs from kit to kit.
(Refer to the below table.)

Cylinder port
Symbol

C3
C4
C6
M5
CM Note 1)
L3
L4
L6

Port size
With 3.2 One-touch fitting
With 4 One-touch fitting
With 6 One-touch fitting
M5 thread
Mixed sizes and with port plug
Top ported elbow with 3.2 One-touch fitting
Top ported elbow with 4 One-touch fitting
Top ported elbow with 6 One-touch fitting

Symbol

L5
B3
B4
B6
B5
LM Note 1)
MM Note 2)

Port size
Top ported elbow M5 thread
Bottom ported elbow with 3.2 One-touch fitting
Bottom ported elbow with 4 One-touch fitting
Bottom ported elbow with 6 One-touch fitting
Bottom ported elbow M5 thread
Elbow port, mixed sizes
Mixed size for different types of piping, option installed

Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -BRS
Note 2) Models with a suffix -B have check valves for
prevention of back pressure at all manifold
stations. When a back pressure check valve is
desired, and is to be installed only in certain
manifold stations, specify the mounting position
by means of the manifold specification sheet.
Note 3) Specify the mounting position by means of the
manifold specification sheet.
Note 4) Refer to page 69 for details on with vacuum
ejector unit. A combination of J and N is not
available.
Note 5) Specify the wiring specifications by means of
the manifold specification sheet. (Except L kit)
Note 6) Indicate R for the valve with external pilot.
Note 7) : Station. Example: D08: The number of stations that may be displayed is longer than the
manifold number of stations.

Note 1) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping or dual flow fitting assembly,
enter MM and give instructions in the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 57 for details.
Note 4) M5 fittings for M5 thread are attached without being incorporated.

Simple specials are available with SMC Simple Specials System.


Refer to Best Pneumatics No. q for details on applicable models.

Kit type/Electrical entry/Cable length

kit
(D-sub connector)

Top entry

kit
(Flat ribbon cable)

Option
None
200/220 VAC models (F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer

kit
(Flat ribbon cable
20P)

kit
(Flat ribbon cable
with terminal block)

Top entry

Top entry

The voltage used for


the valve is 24 VDC.
20P

Note 1)

Note 1)

25P

20P

26P

Side entry

Connector entry direction


Top entry Side entry
U0
S0
F U1 F S1
kit U2 kit S2
U3
S3

Connector entry direction


Top entry Side entry
Without cable
U0
S0
Note 2)
With cable (1.5 m)
P U1 P S1
2 to 24
kit U2 kit S2
With cable (3 m)
stations
With cable (5 m)
U3
S3

P. 17

Side entry

Side entry

Connector entry direction


Top entry Side entry
Without cable
U0
S0
Note 2)
With cable (1.5 m)
J U1 J S1
2 to 24
kit U2 kit S2
With cable (3 m)
stations
With cable (5 m)
U3
S3

P. 21

P. 25
Without cable
Note 2)
With cable (1.5 m)
2 to 16 G
With cable (3 m)
kit
stations
With cable (5 m)

Note 1) Besides the above, F/P kit with different number of pins are available. Refer to page 55 for details.
Note 2) Refer to page 56 for details.

Order separately
SI unit made by
OMRON Corp.

P. 29
0
1
2
3

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

Note 2)

2 to 16
stations

Base Mounted Plug-in Unit


Note) For CE compliant
models, DC-type
only.
[Option]

VQ 1 1 0 0

Example

CE compliant

Series

Nil

VQ1000

Double solenoid
(24 VDC)
VQ1200-51 (4 sets)

Single solenoid (24 VDC)


VQ1100-51 (4 sets)

CE compliant

Blanking plate
VVQ1000-10A-1 (1 set)

sid
e

VQ

-1

00

-5

12

00

-5

12

00

-5

00

-5

-5

-5

11

00

-5

DC

C: Locking type
(Manual)

AC

(0.4 W)

Standard

High-speed (0.95 W)
response type

Cylinder port
fitting port size
C6: With 6 One-touch
fitting

D-sub connector
cable assembly
AXT100-DS25-030

Note 1)

F kit
(D-sub connector)
B

Nil

D: Slide locking
type (Manual)

Metal

0A

-5

12

11

00

11

Rubber

-1

00

12

00

10

00

2-position double

Manifold base (9 stations)


VV5Q11-09C6FU2

High-pressure type (0.95 W)

K Note 2) (1.0 MPa)


3-position exhaust center

4
3-position pressure center

5
4-position dual 3-port valve
4
2
(A)
5
N.C.

3
N.C.

4-position dual 3-port valve


4
2
(B)
5
N.O.

C Note)

11

Function
Symbol Specifications

B Note)

2-position double

3-position closed center

A Note)

Metal seal
Rubber seal

0
1

12
VQ
00
-5
12
VQ
00
-5
12
VQ
00
-5
12
VQ
00
-5
11
VQ
00
-5
11
VQ
00
-5
1
10
VQ
0-5
11
00
-5

Nil: Non-locking B: Locking


push type
type
(Tool required)
(Tool required)

Seal

2-position single

VV
Q1
00
0-1
0A
-1

Manual override

Type of actuation

3m

Note) For CE compliant


models, DC-type only.

S
ta
tio
ns

How to Order Manifold Assembly

sid
e

How to Order Valves

Series VQ1000

3
N.O.

4-position dual 3-port valve


4
2
(C)
5
N.C.

Note 3)

Negative
common

R Note 3)

External
pilot

VV5Q11-09C6FU2
VQ1100-51
VQ1200-51
VVQ1000-10A-1

Light/surge
voltage suppressor
Yes
None

Nil

E Note)

Note 1) Refer to page 16 for


power consumption
of AC type.
Note 2) Metal seal only
Note 3) For external pilot and negative common specifications,
refer to Semi-standard on
pages 56 to 57.
Note 4) When two or more symbols
are specified, indicate them
alphabetically. Combination
of [B] and [K] is not possible.

The asterisk denotes the symbol for assembly.


Prefix it to the part nos. of the solenoid valve, etc.

Note) Not applicable to the S kit.

Coil voltage
1
2 Note)
3
4 Note)
5
6

Note) Rubber seal only

100 VAC (50/60 Hz)


200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

1 set (F kit 9-station manifold base part no.)


4 sets (Single solenoid part no.)
4 sets (Double solenoid part no.)
1 set (Blanking plate part no.)

CE compliant

Specify the part numbers for valves and options together


beneath the manifold base part number. Besides, when the
arrangement will be complicated, specify them by means of
the manifold specification sheet.

Note) 200 and 220 VAC:


F/L kit only

3
N.O.

Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.

kit
(Terminal block box)

kit
(Lead wire)

kit
(Serial transmission)
The valve is equipped with an
indicator light and surge voltage
suppressor, and the voltage is 24
VDC. The dust proof SI unit is
also available. Refer to page 45
for details.
Note) Refer to SI Unit Part No. on
page 45 when ordering the
CE-compliant
P. 45
SI unit.

3
4
1
2
4
3
2
3

2
1

P.
P. 33
T kit

O Terminal block box 2 to 24 stations Note 2)

L
kit

0
1
2

With cable (0.6 m)


With cable (1.5 m)
With cable (3 m)

0
F1
H
J1
J2
S
Q
kit
R1
37
R2
V
1 to 8
ZB
stations
ZBN

Without SI unit
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
CompoNet (Positive common)
CompoNet (Negative common)

Note 2)

Max.16
stations
Max. 8 stations

Max.16
stations
Max. 8 stations

Max. 16
stations

VQ-A.qxd

09.2.26 2:36 PM

Page 10

Series VQ1000
VQ1000: Manifold Options

P. 65 to 69

Blanking plate assembly

Individual SUP spacer

Individual EXH spacer

SUP block plate

VVQ1000-10A-1

VVQ1000-P-1- C6
N7

VVQ1000-R-1- C6
N7

VVQ1000-16A

C6 (SUP port)
6 one-touch fitting

Back pressure check valve


assembly [-B]

EXH block base assembly


Blanking plate with connector

F C3, C4
M5
VVQ1000-19A- P - C6,
N1, N3
L N7

VVQ1000-18A

Name plate [-N]


VVQ1000- N
NC -Station
(1 to Max. stations)
7

VVQ1000-1C-

C6 (EXH port)
6 one-touch fitting

Connector assembly

DIN rail mounting bracket

[-D/-D0/-D]
VVQ1000-57A

Blanking plug

Port plug

Elbow fitting assembly

KQ2P-

VVQ0000-58A

VVQ1000-F-L

Direct EXH outlet with


built-in silencer

Dual flow fitting assembly

Silencer (For EXH port)

[-S]

VVQ1000-52A- C8
N9

AN200-KM8/AN203-KM8
Refer to back page 4 for cylinder
port fittings part number.
Refer to page 62 for replacement
parts.

Exhaust

Regulator unit

Double check block

With ejector unit

VVQ1000-AR-1

VQ1000-FPG--

[-J]

SE

To
CY
po L
rt

VQ-A.qxd

09.2.26 2:36 PM

Page 11

10

Plug-in Unit
Base Mounted

Series VQ2000

[Option]
Note) For CE compliant
models, DC-type only.

How to Order Manifold


Option

VV5Q 2 1 08 C6 F U1

Symbol
Nil

Series
2

CE compliant

VQ2000

Nil

Manifold
1

Note) For CE compliant


models, DC-type only.

Plug-in unit

Stations
01

1 station

Kit type

Cylinder port
Symbol

C4
C6
The maximum and
minimum number of
C8
stations are varied
CM Note 1)
depending on kit.
L4
(Refer to the below
L6
table.)

2
B Note 2)
D
D0
D Note 5)
K Note 3)
N
R Note 4)
S

CE compliant

Port size
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
Mixed sizes and with port plug
Top ported elbow with 4 One-touch fitting
Top ported elbow with 6 One-touch fitting

Symbol

L8
B4
B6
B8
LM Note 1)
MM Note 2)

Port size
Top ported elbow with 8 One-touch fitting
Bottom ported elbow with 4 One-touch fitting
Bottom ported elbow with 6 One-touch fitting
Bottom ported elbow with 8 One-touch fitting
Elbow port, mixed sizes
Mixed size for different types of piping, option installed

Note 1) When two or more symbols are specified, indicate them alphabetically. Example: -DNR
Note 2) Models with a suffix -B have check valves for
prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by
means of the manifold specification sheet.
Note 3) Specify the wiring specifications by means of
the manifold specification sheet. (Except L kit)
Note 4) Indicate R for the valve with external pilot.
Note 5) : Station. Example: D08: The number of stations that may be displayed is longer than the
manifold number of stations.

Note 1) Indicate Mixed size and with port plug by means of the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter MM and give
instructions in the manifold specification sheet.
Note 3) Inch-size One-touch fittings are also available. Refer to page 57 for details.
Simple specials are available with SMC Simple Specials System.
Refer to Best Pneumatics No. q for details on applicable models.

Kit type/Electrical entry/Cable length


kit
kit
(Flat ribbon cable)
(D-sub connector)

Side entry

Note 1)

Option
None
200/220 VAC models (F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof
(IP65) (T/L/S/M kit only)

kit
(Flat ribbon cable
20P)

kit
(Flat ribbon cable
with terminal block)

Side entry

Side entry

The voltage
used for the
valve is 24
VDC.

Note 1)

25P

26P
Top entry

Connector entry direction


Top entry Side entry
U0
S0
F U1 F S1
kit U2 kit S2
U3
S3

20P
Top entry

Connector entry direction


P. 17
Top entry Side entry
Without cable
U0
S0
Note 2)
With cable (1.5 m)
U1 P S1
P
2 to 24
kit U2 kit S2
With cable (3 m)
stations
With cable (5 m)
U3
S3

kit
(Terminal block
box)

Top entry

Connector entry direction


P. 21
Top entry Side entry
Without cable
U0
S0
Note 2)
With cable (1.5 m)
U1 J S1
J
2 to 24
kit U2 kit S2
With cable (3 m)
stations
With cable (5 m)
U3
S3

kit
(Lead wire)

P. 25

P. 29

Without cable
U0
Note 2)
With cable (1.5 m)
U1
G
2 to 16
kit U2
With cable (3 m)
stations
With cable (5 m)
U3

Note 4)
kit
(Serial transmission)

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

The valve is equipped with an indicator light and surge voltage suppressor, and the voltage is 24
VDC. The dusttight SI unit is available. Refer to page 45 for details.
Dust-tight, Water-jet-proof (IP65)
is available.
Note) Refer to SI Unit Part No. on page 45 when
ordering the CE-compliant SI unit.

Note 2)

2 to 16
stations

kit
(Circularconnector)

P. 45

0 Without SI unit
F1 NKE Corp.: Uni-wire System
H NKE Corp.: Uni-wire H System

Note 2)

Max.16
stations

J1 SUNX Corp.: S-LINK (16 outputs)

Dust-tight/Water-jet-proof
(IP65) compatible
P.
Dust-tight/Water-jet-proof
(IP65) compatible
T kit

11

P. 33

O Terminal block box 2 to 20 stations Note 2)

L
kit

0
1
2

S
kit

37

With cable (0.6 m)


1 to 8
With cable (1.5 m)
stations
With cable (3 m)

Note 1) Besides the above, F/P kit with different number of pins are available.
Refer to page 55 for details.
Note 2) Refer to page 56 for details.

J2 SUNX Corp.: S-LINK (8 outputs)

Max. 8 stations

Q DeviceNet

Max.16

P. 51

R1 OMRON Corp.: CompoBus/S (16 outputs) stations


R2 OMRON Corp.: CompoBus/S (8 outputs)
V CC-LINK
ZB CompoNet (Positive common)
ZBN CompoNet (Negative common)

Max. 8 stations

M
Max.16
kit

stations

0
1
2
3

Without cable
Note 2)
With cable (1.5 m)
2 to 24
With cable (3 m)
stations
With cable (5 m)

Note 3) Refer to the pages on respective kits for IP65 type. (T/L/S kit)
Note 4) Serial transmission system with IP65 enclosure applicable to input/output
is also available. Refer to page 49 for details.

Series VQ2000

Base Mounted Plug-in Unit


Note) For CE compliant
models, DC-type
[Option]
only.

How to Order Valves

VQ 2 1 0 0

Example
Double solenoid (24 VDC)
VQ2200-51 (4 sets)

Series
2

How to Order Manifold Assembly

CE compliant

VQ2000

Nil

CE compliant

Single solenoid (24 VDC)


VQ2100-51 (3 sets)

Blanking plate
VVQ2000-10A-1 (1 set)

sid

0
1

Metal seal
Rubber seal

2-position single

A Note)

4-position dual 3-port valve


4
2
(A)

Rubber

Metal

5
N.C.

Nil

W Note)

Dust-tight/water-jetproof type (IP65)

S
ta
tio
ns

e
sid
D

VV
VQ Q20
00
22
VQ
-10
00
22
-51
VQ
A-1
00
22
-5
00
22
-51 1
0
0-5
21
V
1
VQ Q210 00-5
1
21
0-5
00
1
-51
VQ

VQ

Note) T, L, S and M kits only

Type of actuation
1

3m

Enclosure

Seal

Note) For CE compliant


models, DC-type only.

2-position double

B Note)

C Note)

Nil

E Note)

Cylinder port fitting port size


C8: With 8 One-touch fitting

F kit
(D-sub connector)

Yes
None

Manifold base (8 stations)


VV5Q21-08C8FU2

Note) Not applicable to the


S kit.

3
N.O.

4-position dual 3-port valve


4
2
(C)
5
N.C.

3-position closed center

3
N.C.

4-position dual 3-port valve


4
2
(B)
5
N.O.

2-position double

D-sub connector
cable assembly
AXT100-DS25-030

Light/surge
voltage suppressor

Coil voltage

3
N.O.

1
2 Note)
3
4 Note)
5
6

Note) Rubber seal


only

3-position exhaust center

100 VAC (50/60 Hz)


200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

CE compliant

VV5Q21-08C8FU2
VQ2100-51
VQ2200-51
VVQ2000-10A-1

1 set (F kit 8-station manifold base part no.)


3 sets (Single solenoid part no.)
4 sets (Double solenoid part no.)
1 set (Blanking plate part no.)

The asterisk denotes the symbol for assembly.


Prefix it to the part nos. of the solenoid valve, etc.

Specify the part numbers for valves and options together


beneath the manifold base part number. Besides, when the
arrangement will be complicated, specify them by means of
the manifold specification sheet.

Note) 200 and 220 VAC:


F/L kit only

3-position pressure center

Manual override

Nil: Non-locking push type


(Tool required)
Note) For sub-plate single unit
type, refer to page 54.

Function
Symbol

Specifications

Nil

Standard

High-speed
response type

K Note 2)

DC
(0.4 W)

AC

B: Push-locking slotted type


(Tool required)

Note 1)

(0.95 W)

C: Locking type (Manual)

High-pressure type (0.95 W)


(1.0 MPa)

N Note 3)

Negative
common

R Note 3)

External
pilot

D: Slide locking type (Manual)

Note 1) For power consumption of AC type, refer


to page 16.
Note 2) Metal seal only
Note 3) For external pilot and negative common
specifications, refer to Semi-standard on
pages 56 to 57.
Note 4) When two or more symbols are specified,
indicate them alphabetically. Combination
of [B] and [K] is not possible.

Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.

12

VQ-A.qxd

09.2.26 2:36 PM

Page 14

Series VQ2000
VQ2000: Manifold Options

P. 71 to 75

Blanking plate assembly

Individual SUP spacer

Individual EXH spacer

SUP block plate

VVQ2000-10A-1

VVQ2000-P-1- C8
N9

VVQ2000-R-1- C8
N9

VVQ2000-16A

C8 (EXH port)
8 one-touch
fitting

C8 (SUP port)
8 one-touch
fitting

SUP stop valve spacer

Back pressure check valve


assembly [-B]

Name plate [-N]


VVQ2000-N-Station

VVQ2000-19A

VVQ2000-24A-1

VVQ2000-18A

(1 to Max. stations)

DIN rail mounting bracket


Blanking plug

Port plug

Direct EXH outlet with


built-in silencer

KQ2P-

VVQ1000-58A

[-D/-D0/-D]
VVQ2000-57A

Silencer (For EXH port)

Elbow fitting assembly

Dual flow fitting assembly

AN200-KM10

VVQ2000-F-L

VVQ2000-52A- C10
N11

EXH block plate

[-S]

Refer to back page 4 for cylinder


port fittings part number.
Refer to page 64 for replacement
parts.

Double check block


(Separated)

Double check block


(Direct mounting)

VQ2000-FPG--

VVQ2000-23A-

IN

IN

B
B

13

To
CY
po L
rt

Color: red

VQ-A.qxd

09.2.26 2:36 PM

Page 15

14

VQ-A.qxd

09.2.26 2:36 PM

Page 16

Plug-in Unit
Base Mounted

Series VQ1000/2000

Model
Flow-rate characteristics Note 1)
Series

Type of
actuation

1 2/4 (P A/B)

Model

2-position
3-position
4-position
2-position
3-position
4-position

VQ2000

2/4 3/5 (A/B R1/R2)

AC

C [dm /(sbar)]

Cv

C [dm /(sbar)]

Cv

Metal seal

VQ1100

0.70

0.15

0.16

0.72

0.25

0.18

15 or less

12 or less

29 or less

Rubber seal

VQ1101

0.85

0.20

0.21

1.0

0.30

0.25

20 or less

15 or less

34 or less

Metal seal

VQ1200

0.70

0.15

0.16

0.72

0.25

0.18

13 or less

10 or less

13 or less

Rubber seal

VQ1201

0.85

0.20

0.21

1.0

0.30

0.25

20 or less

15 or less

20 or less

Closed
center

Metal seal

VQ1300

0.68

0.15

0.16

0.72

0.25

0.18

26 or less

20 or less

40 or less

Rubber seal

VQ1301

0.70

0.20

0.16

0.65

0.42

0.18

33 or less

25 or less

47 or less

Exhaust
center

Metal seal

VQ1400

0.68

0.15

0.16

0.72

0.25

0.18

26 or less

20 or less

40 or less

Rubber seal

VQ1401

0.70

0.20

0.16

1.0

0.30

0.25

33 or less

25 or less

47 or less

Pressure Metal seal


center
Rubber seal

VQ1500

0.70

0.15

0.16

0.72

0.25

0.18

26 or less

20 or less

40 or less

VQ1501

0.85

0.20

0.21

0.65

0.42

0.18

33 or less

25 or less

47 or less

Dual
Rubber seal
3-port valve

A
VQ1 B 01
C

0.70

0.20

0.16

0.70

0.20

0.16

33 or less

25 or less

47 or less

Metal seal

VQ2100

2.0

0.15

0.46

2.6

0.15

0.60

29 or less

22 or less

49 or less

Rubber seal

VQ2101

2.2

0.28

0.55

3.2

0.30

0.80

31 or less

24 or less

51 or less

Metal seal

VQ2200

2.0

0.15

0.46

2.6

0.15

0.60

20 or less

15 or less

20 or less

Rubber seal

VQ2201

2.2

0.28

0.55

3.2

0.30

0.80

26 or less

20 or less

26 or less

Closed
center

Metal seal

VQ2300

2.0

0.15

0.46

2.0

0.18

0.46

38 or less

29 or less

58 or less

Rubber seal

VQ2301

2.0

0.28

0.49

2.2

0.31

0.60

44 or less

34 or less

64 or less

Exhaust
center

Metal seal

VQ2400

2.0

0.15

0.46

2.6

0.15

0.60

38 or less

29 or less

58 or less

Rubber seal

VQ2401

2.0

0.28

0.49

3.2

0.30

0.80

44 or less

34 or less

64 or less

Pressure Metal seal


center
Rubber seal

VQ2500

2.4

0.17

0.57

2.0

0.18

0.46

38 or less

29 or less

58 or less

VQ2501

3.2

0.28

0.80

2.2

0.31

0.60

44 or less

34 or less

64 or less

1.8

0.28

0.46

1.8

0.28

0.46

44 or less

34 or less

64 or less

Single

Double

Single

Double

Dual
Rubber seal
3-port valve

VQ2 B 01
C

Note 1) The values are given for port size C6: (VQ1000), C8: (VQ2000) without back pressure check valve.
Note 2) As per JIS B 8375-1981 (Supply pressure 0.5 MPa; with indicator light/surge voltage suppressor; clean air
The response time is subject to the pressure and quality of the air.) The values at the time of ON are given for double types.

15

High-speed
response:
0.95 W

Standard:
0.4 W

VQ1000

Response time (ms) Note 2)


Mass
(g)

67

77

95

105

VQ-A.qxd

09.2.26 2:36 PM

Page 17

Base Mounted Plug-in Unit

Series VQ1000/2000

Standard Specifications
JIS symbol

Fluid

Valve specifications

Metal

Rubber seal
Air, Inert gas

0.7 MPa (High-pressure type: 1.0 MPa)

0.7 MPa

Single

0.1 MPa

0.15 MPa

Double

0.1 MPa

0.1 MPa

3-position

0.1 MPa

0.2 MPa

4-position

0.15 MPa

Maximum operating pressure

Rubber

Metal seal
Air, Inert gas

Valve type

2-position single

2-position double

2-position double

3-position closed center

Minimum
operating pressure

10 to 50C Note 1)

Ambient and fluid temperature

Not required

Lubrication

Push type, Locking type (Tool required, Manual) semi-standard

Manual override

150/30 m/s2

Impact/Vibration resistance Note 2)

Dust-protected; Dust-tight, Water-jet-proof (IP65) Note 4)

Enclosure
3-position exhaust center
Electrical specifications

Coil rated voltage

3-position pressure center

4-position dual 3-port valve Note)


4
2
(A)
5
N.C.

3
N.C.

10% of rated voltage

Coil insulation type

Equivalent to Class B

Power consumption
(Current)

4-position dual 3-port valve Note)


4
2
(B)
5
N.O.

3
N.O.

3
N.O.

Note) Rubber seal


only

Manifold Specifications
Series

VQ1000

VQ2000

Base model

VV5Q11-

VV5Q21-

24 VDC

0.4 W DC (17 mA), 0.95 W DC (40 mA) Note 3)

12 VDC

0.4 W DC (34 mA), 0.95 W DC (80 mA) Note 3)

100 VAC

Inrush 0.96 VA (10 mA), Holding 0.96 VA (10 mA)

110 VAC

Inrush 1.0 VA (9 mA), Holding 1.0 VA (9 mA)

200 VAC

Inrush 1.26 VA (6 mA), Holding 1.26 VA (6 mA)

220 VAC

Inrush 1.38 VA (6 mA), Holding 1.38 VA (6 mA)

Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2) Impact resistance No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
Note 3) Value for high-speed response, high-voltage type (0.95 W)
Note 4) Dust-tight, Water-jet-proof (IP65) is available on T/L/S/M kit of the VQ2000.

4-position dual 3-port valve Note)


4
2
(C)
5
N.C.

12 , 24 VDC, 100, 110, 200, 220 VAC (50/60 Hz)

Allowable voltage fluctuation

Connection type

Piping
direction

F kitD-sub connector
P kitFlat ribbon cable
J kitFlat ribbon cable (20P)
G kitFlat ribbon cable with terminal
block
T kitTerminal block box
L kitLead wire
S kitSerial transmission
F kitD-sub connector
P kitFlat ribbon cable
J kitFlat ribbon cable (20P)
G kitFlat ribbon cable with terminal
block
T kitTerminal block box
L kitLead wire
S kitSerial transmission
M kitCircular connector

Piping specifications
Port size Note 1)
1(P), 3(R)
4(A), 2(B)
C8 (8)

Side

Option:
Direct EXH
outlet with
built-in
silencer

C3 (3.2)
C4(4)
C6 (6)
M5 (M5 thread)

Side

Applicable
solenoid valve

F/P/T kit
2 to 24 stations
J/G/S kit
2 to 16 stations

VQ100
VQ101

L kit
1 to 8 stations

5-station
mass
(g)

643
(Single)
754
(Double,
3-position)

F/P kit
2 to 24 stations

C10 (10)
Option:
Direct EXH
outlet with
built-in
silencer

Note 2)

Applicable
stations

C4 (4)
C6 (6)
C8 (8)

J/G/S kit
2 to 16 stations
L kit
1 to 8 stations

VQ200
VQ201

1076
(Single)
1119
(Double,
3-position)

T kit
2 to 20 stations

Note 1) Inch-size one-touch fittings are also available. Refer to page 57 for details.
Note 2) Refer to page 56 for details.

R port

R port

P port

P port
A, B port

A, B port

Type of connection
Type of connection

VV5Q11

VV5Q21

16

Series VQ1000/2000

Kit (D-sub connector)


VV5Q11

 D-sub connector reduces installation labor for electrical connections.


 Using the D-sub connector (25P), (15P as semi-standard) conforming to MIL standard permits the use of connectors put on
the market and gives a wide interchangeability.
 Top or side receptacle position can be selected in accordance
with the available mounting space.
 Maximum stations are 24.

VV5Q21

Manifold Specifications
Piping specifications
Series

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)

VQ1000

Side

C8

VQ2000

Side

C10

Applicable
stations

C3, C4, C6, M5 Max. 24 stations


C4, C6, C8

Max. 24 stations

D-sub Connector (25 Pins)


Cable Assembly 
AXT100-DS25-

015
030
050

Wire color by terminal no. of


D-sub connector cable assembly

The D-sub connector cable assembly can be ordered individually or


included in a specific manifold model no. Refer to How to Order Manifold.
D-sub connector cable assembly

Multi-core vinyl cable


0.3 mm2 x 25 cores

Cable
length (L)

10

1.5 m
3m
5m

Assembly part no.

Electrical characteristics
Item
Property

Note

AXT100-DS25-015
Cable 25 cores
AXT100-DS25-030
x 24AWG
AXT100-DS25-050

44

For other commercial connectors, use a 25 pins


type with female connector conforming to
MIL-C-24308.
Cannot be used for transfer wiring.
2 x M2.6 x 0.45

55
25

Socket side

13

47.04

65 or less

Voltage limit
V, 1 min, AC

1000

Insulation
resistance
M/km, 20C

5 or more

Note) The min. bending radius


of the D-sub connector
cable assembly is 20 mm.

Connector manufacturers example


Fujitsu Limited
Japan Aviation Electronics Industry, Ltd.
J.S.T. Mfg. Co., Ltd.
Hirose Electric Co., Ltd.

16

14

Conductor
resistance
/km, 20C

Terminal no.

Note 1) Types with 15 pins are also available. Refer to page 55 for details.
Note 2) Lengths other than the above are also available. Please contact SMC for details.

Note) For CE compliant


models, DC-type only.

How to Order Manifold

VV5Q 1 1

08 C6

Symbol
Nil

CE compliant
Nil

VQ1000
VQ2000

Manifold
1

Plug-in unit

Stations
02

U
S

Top entry
Side entry

Cylinder port

2 stations

Symbol

24 24 stations
Note) Refer to page 56
for details.

Cable (Length)
0
1
2
3

Port size

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

VQ1000 VQ2000

C3 Note 1) With 3.2 One-touch fitting


With 4 One-touch fitting
C4 Note 1)
With 6 One-touch fitting
C6 Note 1)
With 8 One-touch fitting
C8 Note 1)
M5 thread
M5
CM Note 2) Note 3) Mixed sizes and with port plug
MM Note 4) Mixed size for different types of piping, option installed

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to Semi-standard on page 57 for details.
b

17

CE compliant

Note) For CE compliant


models, DC-type only.

Connector entry
direction

[Option]

Option

U 1

Series
1
2

Terminal no. Lead wire color Dot marking


1
None
Black
2
None
Brown
3
None
Red
4
None
Orange
5
None
Yellow
6
None
Pink
7
None
Blue
8
White
Purple
9
Black
Gray
10
Black
White
11
Red
White
12
Red
Yellow
13
Red
Orange
14
Black
Yellow
15
Black
Pink
16
White
Blue
17
None
Purple
18
None
Gray
19
Black
Orange
20
White
Red
21
White
Brown
22
Red
Pink
23
Red
Gray
24
White
Black
25
None
White

Note 2)

D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S

Option
VQ1000 VQ2000
None
200/220 VAC models
(F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer

Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than
the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for the details on with ejector unit. A combination of J and N is not available.
Note 6) Specify the wiring specifications by means of the manifold
specification sheet.
Note 7) Indicate R for the valve with external pilot.

Series VQ1000/2000

sid
e

J kit

U
sid
e
S
ta
tio
ns

P kit

F kit

Base Mounted Plug-in Unit

 Electrical

Wiring Specifications

Connector
terminal no.

As the standard electrical wiring


specifications, double wiring (connected to SOL. A and SOL. B) is
adopted for the internal wiring of
each station for 12 stations or less,
regardless of valve and option types.
Mixed single and double wiring is
available as semi-standard. Refer to
page 56 for details.

VV5Q21
The total number of stations is tabulated
starting from station one on the D-side.

2-position double
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

0
1

Metal seal
Rubber seal

SOL.A

SOL.B

19

SOL.A

SOL.B

20

SOL.A

SOL.B

21
9

SOL.B

22

SOL.A

10

Station 10

SOL.B

23

SOL.A

11

SOL.B

24

SOL.A

12

SOL.B

25

COM.

13

Station 11
Station 12

Positive
COM spec.

Negative
COM spec.

[Option]

Nil

Q
DC
(0.4 W)

Nil

Standard

High-speed (0.95 W)
response type

AC
Note 1)

CE compliant

Note) For CE compliant


models, DC-type only.

Manual override
Nil

High-pressure type (0.95 W)

K Note 2) (1.0 MPa)

Negative

N Note 3) common
External
pilot

Note 1) Refer to page 16 for power


consumption of AC type.
Note 2) Metal seal only
Note 3) For external pilot and negative common specifications,
refer to Semi-standard on
pages 56 to 57.
Note 4) When two or more symbols
are specified, indicate them
alphabetically. Combination
of [B] and [K] is not possible.

B
C
D

How to Order Manifold Assembly

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

<Example>
D-sub connector kit with cable (3 m)
VV5Q11-09C6FU2

VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
4 setsValve part no. (Stations 3 to 6)
2 setsValve part no. (Stations 7 to 8)
1 setBlanking plate part no. (Station 9)

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Light/surge
voltage suppressor
Nil

1
2
3
4
5
6

ide

Us

Yes
None

Coil voltage
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated, specify
them by means of the manifold specification sheet.

CE compliant

ns

tio
Sta

side
VVQ

1000

-10A

1
-5
00 1
12 -5
Q 00 1
V
12 -5
Q 00 1
V
12 -5
Q 00 1
V
12 -5
Q 00 1
V
11 -5
Q 00 1
V
11 -5
Q 00 1
V
11 0-5
Q
V 110
Q
V

Seal

18

Station 9

Function

R Note 3)

SOL.B

SOL.A

CE compliant

2-position single
3-position closed center

T kit

4
17

3m

Symbol Specifications

1
2
3
4
5
A
B
C

SOL.A
SOL.B
SOL.A

Specify the part numbers for valves and options


together beneath the manifold base part number.

Series

Type of actuation

16

Sub-plate
Single Unit

Note) For CE compliant


models, DC-type only.

VQ 1 1 0 0
VQ1000
VQ2000

SOL.B

Note) When using the negative common specifications,


use valves for negative common. (Refer to page 56.)
Refer to Semi-standard on page 56 for details.

How to Order Valves

1
2

Station 8

15

None
Black
None
Black
None
White
None
None
None
None
None
Black
None
White
White
White
Black
Red
Black
Red
Red
White
Red
None
Red

L kit

sid
D

Station 7

SOL.B
SOL.A

Dot marking

S kit

Station 6

Lead wire color


Black
(+)
Yellow
(+)
Brown
(+)
Pink
(+)
Red
(+)
Blue
(+)
Orange
(+)
Purple
(+)
Yellow
(+)
Gray
(+)
Pink
(+)
Orange
(+)
Blue
(+)
Red
(+)
Purple
(+)
Brown
(+)
Gray
(+)
Pink
(+)
White
(+)
Gray
(+)
White
(+)
Black
(+)
Yellow
(+)
White
(+)
() Note) Orange

-1

Caution
Use the standard (DC) specification when continuously energizing for
long periods of time.

18

Semistandard

Station 5

SOL.A

Polarity

()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)

Construction

S
ta
tio
ns

Station 4

sid

Station 3

1
14

Exploded
View of
Manifold

Station 2

VV5Q11

SOL.A
SOL.B

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Terminal no.
Station 1

M kit

015
AXT100-DS25- 030 Wire color
050

G kit

D-sub connector assembly

D-sub connector

Series VQ1000/2000
kit (D-sub connector)

VV5Q11

< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].

(L4)
(L3)
L2
L1

Applicable connector: D-sub connector (25P)


(Complies with MIL-C-24308)
13.5

63.5 <67.5>
(12)

(5.25)

28

P = 10.5

13

27

Indicator light
Manual
override

(5.5)

4.8

1.5

40.5

(35)

93.5 <100.4>
66

M4 mounting hole

35[25]
61

D side

Stations

U side

[ ]: 25 pins (top entry)


C8 [3(R) EXH port]
C8: 8 one-touch fitting

18.7
7.7

DIN rail clamp screw

9.3
25
40.7

(7.5)

(12)

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

Dimensions
n

L1
L2
(L3)
(L4)

C8 [1(P) SUP port]


C8: 8 one-touch fitting

Formula L1 = 10.5n + 44.5, L2 = 10.5n + 62.5

65.5

76

86.5

97

107.5 118

128.5 139

149.5 160

170.5 181

191.5 202

212.5 223

233.5 244

254.5 265

275.5 286

296.5

83.5

94

104.5 115

125.5 136

146.5 157

167.5 178

188.5 199

209.5 220

230.5 241

251.5 262

272.5 283

293.5 304

314.5

187.5 187.5 200

212.5 225

237.5 250

250

112.5 125
123

125

137.5 150

135.5 135.5 148

162.5 175

160.5 173

185.5 198

10

198

11

12

210.5 223

13

14

235.5 248

15

16

17

18

262.5 275

260.5 260.5 273

19

n: Station (Maximum 24 stations)

With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 46.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

19

18.1
31.4

P = 10.5

20

287.5 300

285.5 298

21

22

312.5 325

310.5 323

23

325

24

337.5

335.5 335.5 348

VQ-A.qxd

09.2.26 2:36 PM

Page 21

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

VV5Q21

(L4)
(L3)
L2
L1

73.5 <77.5>

34.5

13

34.5

P = 16
0.9

Indicator light

6.5
1

Manual
override

U side

Sub-plate
Single Unit

C10 [3(R) EXH port]


C10: 10 one-touch fitting

EXH

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting P = 16
C8: 8 one-touch fitting

(7.5)
(12)

Construction

23

Exploded
View of
Manifold

16
31.6

49

24.5
9.5

DIN rail clamp screw

EXH

41
C10 [1(P) SUP port]
C10: 10 one-touch fitting

Dimensions
n

L1
L2
(L3)
(L4)

Formula L1 = 16n + 53, L2 = 16n + 73

n: Station (Maximum 24 stations)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

325

341

357

373

389

405

421

437

105

121

137

153

169

185

201

217

233

249

265

281

297

313

329

345

361

377

393

409

425

441

457

212.5 225

250

262.5 275

300

312.5 325

337.5 350

375

387.5 400

137.5 150
148

162.5 187.5 200

160.5 173

198

210.5 223

235.5 260.5 273

285.5 310.5 323

335.5 348

360.5 385.5 398

412.5 437.5 450

410.5 423

448

462.5 487.5

460.5 473

Semistandard

498

20

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

D side Stations

M kit

4 x M5 mounting hole

10.6
4

35
39.5

S kit

46.2

(35)

120 <126.9>
80

(5.5)

L kit

(12)

(5.25)

G kit

4.5

T kit

Applicable connector: D-sub connector (25P)


(Complies with MIL-C-24308)

J kit

P kit

< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-FS].

Series VQ1000/2000
kit (Flat ribbon cable)
VV5Q11

 MIL flat ribbon cable connector reduces installation labor for


electrical connection.
 Using the connector for flat ribbon cable (26P) conforming to
MIL standard permits the use of connectors put on the market
and gives a wide interchangeability.
 Top or side receptacle position can be selected in accordance
with the available mounting space.
 Maximum stations are 24.

VV5Q21

Manifold Specifications
Piping specifications
Series

Applicable
stations

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
Side

C8

VQ2000

Side

C10

C3, C4, C6, M5 Max. 24 stations


C4, C6, C8

Max. 24 stations

sid
e
S
ta
tio
ns

VQ1000

sid
e

Flat Ribbon Cable (26 Pins)


AXT100-FC26-

Cable Assembly 
1
to
3

Flat ribbon cable connector assembly can be ordered individually or


included in a specific manifold model no. Refer to How to Order Manifold.
Red

tio
ta

sid

Terminal no.

sid

ns

VV5Q11

Flat Ribbon Cable Connector Assembly


Cable length (L)

Assembly part no.


AXT100-FC26-1
AXT100-FC26-2
AXT100-FC26-3

1.5 m
3m
5m

Note
Cable 26 cores
x 28AWG

For other commercial connectors, use a 26 pins type with strain relief
conforming to MIL-C-83503.
Cannot be used for transfer wiring.

Connector manufacturers example


Hirose Electric Co., Ltd.
Sumitomo 3M Limited

Fujitsu Limited
Japan Aviation Electronics
Industry, Ltd.

The total number of stations is tabulated starting


from one on the D-side.

Note 1) Other than the above model, 10P, 16P, 20P are also available. Refer to page 55 for details.
Note 2) Lengths other than the above are also available. Please contact SMC for details.

Note) For CE compliant


models, DC-type only.

How to Order Manifold

VV5Q 1 1

08 C6

PU

CE compliant

VQ1000
VQ2000

Connector entry
direction

Manifold
1

Stations
02

U
S

Plug-in unit
2 stations

Cylinder port
Symbol

C3 Note 1)
24 24 stations
C4 Note 1)
Note) Refer to
C6 Note 1)
page 56
C8 Note 1)
for details.
M5
CM Note 2) Note 3)
MM Note 4)

21

Top entry
Side entry

Port size
VQ1000 VQ2000
With 3.2 One-touch fitting
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
M5 thread
Mixed sizes and with port plug
Mixed size for different types of piping, option installed

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter MM and give
instructions in the manifold specification sheet.
Note 5) Inch-size one-touch fittings are available. Refer to Semi-standard on page
57 for details.

[Option]

Option

Series
1
2

VV5Q21

J.S.T. Mfg. Co., Ltd.


Oki Electric Cable Co., Ltd.

Nil

CE compliant

Note) For CE compliant


models, DC-type only.

Cable (Length)
0
1
2
3

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

Symbol
Nil

B Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S

Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer

Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all
manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the
manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of
stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J and N is not
available.
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.

Series VQ1000/2000

J kit

P kit

F kit

Base Mounted Plug-in Unit

Station 4
Station 5
Station 6
Station 7
Station 8
Station 9

Connector
terminal no.

Station 10

SOL.B

SOL.A

SOL.B

SOL.A

SOL.B

10

SOL.A

11

SOL.B

12

SOL.A

13

SOL.B

14

SOL.A

15

SOL.B

16

SOL.A

17

SOL.B

18

SOL.A

19

SOL.B

20

SOL.A

Station 11

SOL.B

SOL.A

Station 12

SOL.B

Triangle mark
indicator position

21
22
23
24

COM.

25

COM.

26

Electrical wiring
specifications

As the standard electrical wiring specifications,


double wiring (connected to SOL. A and SOL. B)
is adopted for the internal wiring of each station
for 12 stations or less, regardless of valve and
option types.
Mixed single and double wiring is available as
semi-standard. Refer to page 56 for details.
Note) When using the negative common
specifications, use valves for negative common. (Refer to page 56,)
Refer to Semi-standard on page 56
for details.

Note) For CE compliant


models, DC-type only.

How to Order Valves

VQ 1 1 0 0

Specify the part numbers for valves and options


together beneath the manifold base part number.

Nil

VQ1000
VQ2000

Nil

2-position double

B
C
D

3-position closed center


3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)

Nil

4-position dual port (N.C. +N.O.)

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Symbol Specifications

Caution

DC
(0.4 W)

Nil

Standard

High-speed (0.95 W)
response type
High-pressure type (0.95 W)

Note 2)

Note 3)

Negative
common

R Note 3)

External
pilot

(1.0 MPa)

Yes
None

AC
Note 1)

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.
ide

Us

ns

tio
Sta

Coil voltage

Function

Seal

Use the standard (DC)


specification when continuously
energizing for long periods of
time.

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
4 setsValve part no. (Stations 3 to 6)
2 setsValve part no. (Stations 7 to 8)
1 setBlanking plate part no. (Station 9)

Light/surge voltage suppressor

4-position dual port (N.O. +N.O.)

Metal seal
Rubber seal

VV5Q11-09C6PU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

Manual override

2-position single

0
1

CE compliant

Note) For CE compliant


models, DC-type only.

Type of actuation
1
2
3
4
5
A
B
C

<Example>
Flat ribbon cable kit with cable (3 m)

CE compliant

Series
1
2

How to Order Manifold Assembly

[Option]

T kit

SOL.A

Station 3

L kit

SOL.B

S kit

SOL.A

Station 2

(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
()
()
Note)
Negative
COM spec.

M kit

Sub-plate
Single Unit

SOL.B

1
3
5
6

100 VAC (50/60 Hz)


110 VAC (50/60 Hz)
24 VDC
12 VDC

CE compliant

Note 1) Refer to page 16 for power consumption of AC type.


Note 2) Metal seal only
Note 3) Refer to Semi-standard on pages 56
to 57 for external pilot and negative
common specifications.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

ide
Ds
V

VVQ
1000
VQ
-10A
13
-1
00
-51

Q1
30
VQ
0-5
12
1
VQ
00
-51
12
VQ
00
11
-51
VQ
00
-51
11
VQ
00
-51
11
VQ
00
11
-5
1
00
-51

22

Semistandard

Station 1

Polarity
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)
(+)
Positive
COM spec.

Construction

Exploded
View of
Manifold

SOL.A

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Terminal no.

Flat ribbon cable connector

G kit

Wiring Specifications

3m

 Electrical

VQ-A.qxd

09.2.26 2:36 PM

Page 24

Series VQ1000/2000

kit (Flat ribbon cable)

VV5Q11

< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].

(L4)
(L3)

Applicable connector: Flat ribbon cable connector (26P)


(Complies with MIL-C-83503)

23.5

63.5 <67.5>
(12)

(5.25)
L2
L1

8.8

28

P = 10.5

13

27

Indicator light

Manual
override

(5.5)

4.8

1.5

40.5

(35)

93.5 <100.4>
66

M4 mounting hole
35
52
61.5

D side

Stations

U side
C8 [3(R) EXH port]
C8: 8 one-touch fitting

9.3
25
40.7

18.7
7.7

DIN rail clamp screw

(7.5)

(12)

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

Dimensions
n

L1
L2
(L3)
(L4)

C8 [1(P) SUP port]


C8: 8 one-touch fitting

Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5

65.5

76

86.5

97

107.5 118

128.5 139

149.5 160

170.5 181

191.5 202

212.5 223

233.5 244

254.5 265

275.5 286

296.5

78.5

89

99.5 110

120.5 131

141.5 152

162.5 173

183.5 194

204.5 215

225.5 236

246.5 257

267.5 278

288.5 299

309.5

187.5 187.5 200

212.5 225

225

287.5 287.5 300

312.5 325

337.5

112.5 125
123

125

137.5 150

135.5 135.5 148

162.5 175

160.5 173

185.5 198

10

198

11

12

210.5 223

13

14

15

16

237.5 250

235.5 235.5 248

17

18

262.5 275

260.5 273

19

n: Station (Maximum 24 stations)

With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 41.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

23

18.1
31.5

P = 10.5

285.5 298

20

298

21

22

310.5 323

23

24

335.5 348

VQ-A.qxd

09.2.26 2:36 PM

Page 25

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

VV5Q21

P kit

< >: AC
The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-PS].

Applicable connector: Flat ribbon cable connector (26P)


(Complies with MIL-C-83503)

L2
L1

Indicator light

J kit

13

P = 16
0.9

34.5
Manual
override

T kit

4 x M5 mounting hole

23.5
(L3)
(L4)

73.5

D side Stations

S kit

52

(5.25)

M kit

35

U side

C10 [3(R) EXH port]


C10: 10 one-touch fitting

EXH

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting P = 16
C8: 8 one-touch fitting

(7.5)
(12)

Construction

23
41

Exploded
View of
Manifold

49

Semistandard

24.5
9.5

DIN rail clamp screw

EXH

16
31.6

Flat ribbon cable connector assembly (26P)


AXT100-FC26-1: 1.5 m
AXT100-FC26-2: 3 m
AXT100-FC26-3: 5 m

C10 [1(P) SUP port]


C10: 10 one-touch fitting

Dimensions
n

L1
L2
(L3)
(L4)

Formula L1 = 16n + 53, L2 = 16n + 68

n: Station (Maximum 24 stations)

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

325

341

357

373

389

405

421

437

100

116

132

148

164

180

196

212

228

244

260

276

292

308

324

340

356

372

388

404

420

436

452

125

150

162.5 175

412.5 425

450

462.5 475

135.5 160.5 173

187.5 212.5 225

185.5 198

223

237.5 262.5 275

235.5 248

273

Sub-plate
Single Unit

10.6
4

L kit

46.2

(35)

120 <126.9>
80

(5.5)

G kit

287.5 300

285.5 298

312.5 337.5 350

310.5 323

348

362.5 387.5 400

360.5 373

398

410.5 423

435.5 460.5 473

485.5

24

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

(12)

6.5

34.5

73.5 <77.5>

Series VQ1000/2000
kit (Flat ribbon cable)
VV5Q11

 MIL flat ribbon cable connector reduces installation labor for


electrical connection.
 Using the connector for flat ribbon cable connectors (20P) conforming to MIL standard permits the use of connector put on
the market and gives a wide interchangeability.
 Top or side receptacle position can be selected in accordance
with the available mounting space.
 Maximum stations are 16.

VV5Q21

Manifold Specifications
Piping specifications
Series

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)
Side

C8

VQ2000

Side

C10

C3, C4, C6, M5 Max. 16 stations


C4, C6, C8

Max. 16 stations

U
s
S ide
ta
tio
ns

VQ1000

Applicable
stations

sid
e

Flat Ribbon Cable (20 Pins)


D

Cable Assembly 
1

AXT100-FC20- to
3

Flat ribbon cable connector assembly can be ordered individually or


included in a specific manifold model no. Refer to How to Order Manifold.
Red

ns

ta

tio

sid

Terminal no.

VV5Q11

1.5 m
3m
5m

AXT100-FC20-1
AXT100-FC20-2
AXT100-FC20-3

sid

Flat Ribbon Cable Connector Assembly


Cable length (L)
Assembly part no.

Note
Cable 20 cores
x 28AWG

For other commercial connectors, use a 20 pins with strain relief


conforming to MIL-C-83503.
Cannot be used for transfer wiring.

Connector manufacturers example


Hirose Electric Co., Ltd.
Sumitomo 3M Limited
Fujitsu Limited

VV5Q21

Japan Aviation Electronics Industry, Ltd.


J.S.T. Mfg. Co., Ltd.
Oki Electric Cable Co., Ltd.

Note) Lengths other than the above are also available. Please contact SMC for details.

The total number of stations is tabulated


starting from one on the D-side.

How to Order Manifold

VV5Q 1 1

[Option]

08 C6

JU

Option

1
CE compliant

Series
1
2

VQ1000
VQ2000

Nil

U
S

Manifold
1

Plug-in unit

Top entry
Side entry

Stations
02

2 stations

Cylinder port
Symbol

16 16 stations
Note) Refer to
page 56
for details.

Connector entry
direction

Port size

Cable (Length)
0
1
2
3

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

VQ1000 VQ2000

With 3.2 One-touch fitting


C3 Note 1)
With 4 One-touch fitting
C4 Note 1)
With 6 One-touch fitting
C6 Note 1)
With 8 One-touch fitting
C8 Note 1)
M5 thread
M5
CM Note 2) Note 3) Mixed sizes and with port plug
MM Note 4) Mixed size for different types of piping, option installed

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to Semi-standard on page 57 for details.
c

25

CE compliant

Symbol
Nil

B Note 2)
D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S

Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 16)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer

Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J
and N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification
sheet.
Note 7) Indicate R for the valve with external pilot.

Series VQ1000/2000

Wiring Specifications
Terminal no.

Station 2

SOL.B
SOL.A

Triangle
mark
indicator
position

Station 3

SOL.B
SOL.A

Station 4

SOL.B
SOL.A

Station 5

SOL.B
SOL.A

Station 6

SOL.B
SOL.A

Connector
terminal no.

Station 7

SOL.B
SOL.A

Station 8

SOL.B

16
14
12
10
8
6
19
17
15
13
11
9
7
5

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

()
()

(+)
(+)

(+)
(+)

()
()

T kit

18

As the standard electrical wiring specifications, double wiring


(connected to SOL. A and SOL. B) is adopted for the internal wiring
of each station for 8 stations or less, regardless of valve and option
types.
Mixed single and double wiring is available as semi-standard. Refer
to Semi-standard on page 56 for details.
Note) When using the negative common specifications, use
valves for negative common. (Refer to page 56,)
Refer to Semi-standard on page 56 for details.

M kit

4
3

COM.

2
1

Note)

Positive
COM spec.

Positive
COM spec.

How to Order Valves

[Option]

VQ 1 1 0 0

Specify the part numbers for valves and options


together beneath the manifold base part number.

1
CE compliant

1
2

Series

Nil

VQ1000
VQ2000

Q
Nil

B
C
D

2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

Seal
0
1

Metal seal
Rubber seal

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

Light/surge voltage suppressor

<Example>
Flat ribbon cable kit with cable (3 m)
VV5Q11-08C6JU2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

Yes
None

Nil

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
4 setsValve part no. (Stations 3 to 6)
1 setValve part no. (Station 7)
1 setBlanking plate part no. (Station 8)
Write sequentially from the
1st station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Us

ide
Sta

3m

1
2
3
4
5
A
B
C

CE compliant

Manual override

Type of actuation

How to Order Manifold Assembly

tion

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

COM.

side

Coil voltage
5

Function
Symbol Specifications

24 VDC

DC
(0.4 W)

Nil

Standard

High-speed (0.95 W)
response type
High-pressure type (0.95 W) Note 1) Metal seal only
Note 2) Refer to Semi-standard on pages 56 to
57 for external pilot and negative common
Negative
specifications.
common
Note 3) When two or more symbols are specified,
External
indicate them alphabetically. Combination
pilot
of [B] and [K] is not possible.

K Note 1) (1.0 MPa)


N Note 2)
R Note 2)

L kit

SOL.B
SOL.A

S kit

19
17
15
13
11
9
7
5
3
1

Polarity
()
()

Sub-plate
Single Unit

20
18
16
14
12
10
8
6
4
2

20

Semistandard

SOL.A

Station 1

Construction

Flat ribbon cable connector

Exploded
View of
Manifold

 Electrical

G kit

J kit

P kit

F kit

Base Mounted Plug-in Unit

26

09.2.26 2:36 PM

Page 28

Series VQ1000/2000

kit (Flat ribbon cable)

VV5Q11

The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].

(L4)
(L3)

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)

23.5
8.8

63.5

28

P = 10.5

13

27

Indicator light

Manual
override

(5.5)

40.5

type

66

(35)

93.5

4.8

1.5

(12)

(5.25)
L2
L1

VQ-A.qxd

4 x M4 mounting hole
35
52

D side

61.5

Stations

U side

C8 [3(R) EXH port]


C8: 8 one-touch fitting

18.7
7.7
(12)
(7.5)
n

L1
L2
(L3)
(L4)

X
P

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

P = 10.5

18.1
31.5
C8 [1(P) SUP port]
C8: 8 one-touch fitting

Formula L1 = 10.5n + 44.5, L2 = 10.5n + 57.5

10

11

12

13

n: Station (Maximum 16 stations)

65.5

76

86.5

97

107.5

118

128.5

139

149.5

160

170.5

181

191.5

202

212.5

14

15

16

99.5

78.5

89

110

120.5

131

141.5

152

162.5

173

183.5

194

204.5

215

225.5

112.5

125

125

137.5

150

162.5

175

187.5

187.5

200

212.5

225

225

237.5

250

123

135.5

135.5

148

160.5

173

185.5

198

198

210.5

223

235.5

235.5

248

260.5

With ejector unit: Formula L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 41.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

27

9.3
25

Dimensions

DIN rail clamp screw

40.7

VQ-A.qxd

09.2.26 2:36 PM

Page 29

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

VV5Q21

L2
L1

(12)

6.5

34.5

73.5
13

P = 16
0.9

Indicator light

34.5

G kit

23.5

Manual
override
1

(5.5)

T kit

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)

J kit

P kit

The dashed lines indicate the DIN rail mounting [-D] and the side entry connection [-JS].

52

4 x M5 mounting hole
(L3)
(L4)

(5.25)

M kit

73.5

S kit

10.6
4

46.2

L kit

(35)

80

120

PCW type

35

U side

Sub-plate
Single Unit

C10 [3(R) EXH port]


C10: 10 one-touch fitting

EXH

24.5
9.5

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting P = 16
C8: 8 one-touch fitting

(7.5)
(12)

Construction

23

Exploded
View of
Manifold

49

16
31.6

DIN rail clamp screw

EXH

41
C10 [1(P) SUP port]
C10: 10 one-touch fitting

Dimensions
n

L1
L2
(L3)
(L4)

Semistandard

Formula L1 = 16n + 53, L2 = 16n + 68

n: Station (Maximum 16 stations)

10

11

12

13

14

15

16

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

100

116

132

148

164

180

196

212

228

244

260

276

292

308

324

125

150

162.5

175

187.5

212.5

225

237.5

262.5

275

287.5

300

312.5

337.5

350

135.5

160.5

173

185.5

198

223

235.5

248

273

285.5

298

310.5

323

348

360.5

28

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

D side Stations

Series VQ1000/2000

kit (Flat ribbon cable with terminal block)


VV5Q11

 Terminal block for power supply equipped with a 20 pins flat


ribbon cable connection for rationalized connection of valves.
 Solenoid valves and power supply can be connected by the
same cable to a specific output unit that requires power supply
from the output section to the internal circuit.
 Maximum stations are 16.

VV5Q21

Manifold Specifications
Piping specifications
Series

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)

VQ1000

Side

C8

VQ2000

Side

C10

Flat Ribbon Cable (20 Pins)

Applicable
stations

C3, C4, C6, M5 Max. 16 stations


C4, C6, C8

Max. 16 stations

Us
ide
tion
s

Sta

Cable Assembly 

Ds

ide

AXT100-FC20- to
3

The total number of stations is


tabulated starting from station
one on the D-side.

Flat ribbon cable connector assembly can be ordered individually or


included in a specific manifold model no. Refer to How to Order Manifold.
Red
Power supply terminal block
(Terminal screw M3)

Terminal no.

Indicator light

VV5Q11
SI unit made by OMRON Corp.
Mountable for G71-OD16 (Order separately)

ns
tio

D
S

ta

Note
sid
e

Assembly part no.


AXT100-FC20-1
AXT100-FC20-2
AXT100-FC20-3

Cable 20 cores
x 28AWG

Cable length (L)


1.5 m
3m
5m

sid
e

Flat Ribbon Cable Connector Assembly

For other commercial connectors, use a 20 pins type with strain relief
conforming to MIL-C-83503.
Cannot be used for transfer wiring.

Connector manufacturers example


Hirose Electric Co., Ltd.
Sumitomo 3M Limited

Japan Aviation Electronics


Industry, Ltd.
J.S.T. Mfg. Co., Ltd.

Oki Electric Cable


Co., Ltd.
Fujitsu Limited

VV5Q21

Note) Lengths other than the above are also available. Please contact SMC for details.

How to Order Manifold

VV5Q 1 1

[Option]

Option

08 C6 G
CE compliant
Nil

Series
1
2

Connector entry
direction, Top entry

VQ1000
VQ2000

Nil

Manifold
1

VQ1000
VQ2000

Plug-in unit

Cylinder port
Stations
02

2 stations

16 Note)

16 stations

Note) Refer to
page 56
for details.

29

Symbol

Port size

CE compliant

Cable (Length)
0
1
2
3

VQ1000 VQ2000

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to Semi-standard on page 57 for details.

B Note 2)
D
D0
D Note 3)

Without cable
Cable length 1.5 m
Cable length 3 m
Cable length 5 m

With 3.2 One-touch fitting


C3 Note 1)
With 4 One-touch fitting
C4 Note 1)
With 6 One-touch fitting
C6 Note 1)
With 8 One-touch fitting
C8 Note 1)
M5 thread
M5
CM Note 2) Note 3) Mixed sizes and with port plug
MM Note 4) Mixed size for different types of piping, option installed

Symbol
Nil

G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S

Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified
(: Stations 02 to 16)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring specifications
(Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer

Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the
mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J and
N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification
sheet.
Note 7) Indicate R for the valve with external pilot.

Series VQ1000/2000

 Connector

G kit

J kit

P kit

F kit

Base Mounted Plug-in Unit

Assembly

Flat ribbon cable connector

T kit

Electric circuit diagram (Below wiring is the case of all double solenoid connections.)
Terminal no.

SOL.B

14

SOL.A

12

SOL.B

10

SOL.A

SOL.B

SOL.A

Station 5

19

SOL.B

17

Station 6

SOL.A

15

SOL.B

13

SOL.A

11

SOL.B

SOL.A

SOL.B

Station 4

Station 7

Connector terminal no.

16

Station 8

Triangle mark
indicator position

As the standard electrical wiring specifications,


double wiring (connected to SOL. A and SOL. B)
is adopted for the internal wiring of each station
for 8 stations or less, regardless of valve and
option types. Mixed single and double wiring is
available as semi-standard. Refer to page 56 for
details.

L kit

Station 3

18

SOL.A

S kit

Station 2

20

SOL.B

M kit

Station 1

SOL.A

3.4

24 VDC +

Specify the part numbers for valves and options


together beneath the manifold base part number.

1
CE compliant

1
2

Series

Seal

Nil

VQ1000
VQ2000

0 Metal seal
1 Rubber seal

Manual override
Nil

Type of actuation
Coil voltage
5

24 VDC

B
C
D

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

VV5Q11-08C6G2
VQ1100-51
VQ1200-51
VQ1300-51

1 setManifold base part no.


4 setsValve part no. (Stations 1 to 4)
1 setValve part no. (Station 5)
3 setsValve part no. (Stations 6 to 8)

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Light/surge voltage suppressor


Nil

Function
Symbol Specifications
Nil

B
K Note 1)
R Note 2)

Standard

Yes
None

DC
(0.4 W)

Sta U sid
e
tio
ns

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.
3m

2-position single
1
2-position double
2
3-position closed center
3
3-position exhaust center
4
3-position pressure center
5
A 4-position dual port (N.C. +N.C.)
B 4-position dual port (N.O. +N.O.)
C 4-position dual port (N.C. +N.O.)

CE compliant

<Example>
Flat ribbon cable kit with terminal block with cable
(3 m)

Ds

ide

High-speed (0.95 W)
response type
Note 1) Metal seal only
High- pressure type (0.95 W) Note 2) Refer to Semi-standard on page 57 for
external pilot specifications.
(1.0 MPa)
Note 3) When two or more symbols are specified,
External
indicate them alphabetically. Combination
pilot
of [B] and [K] is not possible.

30

Construction

Exploded
View of
Manifold

1 0 0

How to Order Manifold Assembly

V
Q
13
V
Q 00
13 -5
V
Q 00 1
13 -5
V
Q 00 1
12 -5
V
Q 00 1
11 -5
V
Q 00 1
11 -5
V
Q 00 1
11 -5
00 1
-5
1

VQ 1

[Option]

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

How to Order Valves

Semistandard

Sub-plate
Single Unit

1.2

09.2.26 2:36 PM

Series VQ1000/2000
kit (Flat ribbon cable with terminal block)

VV5Q11

The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].

(L4)
(L3)
L2
L1

Indicator light
Power supply terminal block
(Terminal screw M3)
13

63.5

(5.25)

P = 10.5

29

(12) 13

27
Manual
override

(5.5)

Indicator light

40
4.5

66

(35)

93.5

Page 32

VQ-A.qxd

4 x M4 mounting hole
2

43.8
63.4

Triangle mark indicator position

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)

D side Stations

U side
C8 [3(R) EXH port]
C8: 8 one-touch fitting

61
63.5

(12) 18.7
7.7
(7.5)

L1
L2
(L3)
(L4)

X
P

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

P = 10.5

18.1
31.5

C8 [1(P) SUP port]


C8: 8 one-touch fitting

Formula L1 = 10.5n + 45.5, L2 = 10.5n + 63

66.5

77

87.5

98

108.5

119

129.5

140

150.5

161

171.5

182

192.5

203

213.5

84

94.5

10

11

12

13

n: Station (Maximum 16 stations)

14

15

16

105

115.5

126

136.5

147

157.5

168

178.5

189

199.5

210

220.5

231

112.5

125

125

137.5

150

162.5

175

187.5

187.5

200

212.5

225

237.5

250

262.5

123

135.5

135.5

148

160.5

173

185.5

198

198

210.5

223

235.5

248

260.5

273

With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 46.8 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

31

Dimensions
L

9.3
13
25
40.7

DIN rail clamp screw

VQ-A.qxd

09.2.26 2:36 PM

Page 33

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

VV5Q21

P kit

The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).

J kit

Power supply terminal block


(Terminal screw M3)
L2
L1

6.5

Indicator light

34.5
Manual
override

T kit

4 x M5 mounting hole

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)
(L3)
(L4)

D side Stations

(5.25)

M kit

73.5

U side

Sub-plate
Single Unit

35

10.6

46.2

L kit

(35)

80

120

24VDC
+ COM

(5.5)

G kit

(12) 13

P = 16
0.9

C10 [3(R) EXH port]


C10: 10 one-touch fitting

EXH

24.5
9.5

23

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting P = 16
C6: 6 one-touch fitting
C8: 8 one-touch fitting

Dimensions
n

L1
L2
(L3)
(L4)

(7.5)
(12)

Construction

Exploded
View of
Manifold

49

DIN rail clamp screw

Semistandard

EXH
R

16
31.6

Flat ribbon cable connector assembly (20P)


AXT100-FC20-1: 1.5 m
AXT100-FC20-2: 3 m
AXT100-FC20-3: 5 m

S kit

34.5

73.5

41
C10 [1(P) SUP port]
C10: 10 one-touch fitting

Formula L1 = 16n + 53, L2 = 16n + 87

n: Station (Maximum 16 stations)

10

11

12

13

14

15

16

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

119

135

151

167

183

199

215

231

247

263

279

295

311

327

343

150

162.5

175

187.5

212.5

225

237.5

262.5

275

287.5

300

325

337.5

350

362.5

160.5

173

185.5

198

223

235.5

248

273

285.5

298

310.5

335.5

348

360.5

373

32

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Indicator light

Series VQ1000/2000

kit (Terminal block box)


VV5Q21

IP65 compliant

VV5Q11

G 1/2
Electrical entry

sid
e

D
sid
e
S
ta
tio
ns

 This kit has a small terminal block inside a junction box.


The electrical entry port {VQ1000: G 1/2, VQ2000: G 3/4}
permits connection of conduit fittings.
 Maximum stations: 24 (VQ1000), 20 (VQ2000)
 Enclosure: Dust-tight, Water-jet-proof (IP65) compatible
(Series VQ2000)

2 x G 3/4
Electrical entry

Manifold Specifications
Series

VQ1000
VQ2000

VQ

12

12

11

Piping specifications
Applicable
Port size
Piping
stations
direction 1(P), 3(R)
4(A), 2(B)
Side
C8
C3, C4, C6, M5 Max. 24 stations
Side
C10
C4, C6, C8
Max. 20 stations

VQ

VQ

-51

 Electrical

Terminal no.
COM.

Loosen the screws on the terminal block cover and open


it in the direction shown by the arrow. The cover can
then be removed from the terminal block.

Station 1
Station 2
Station 3

M2.5

Station 4

Cover

Step 2. Wiring

The diagram on the left shows the terminal block


wiring schematic. All stations are provided with
double solenoid wiring. Insert each lead wire into the
terminal opening and tighten the screw directly
above.
How to connect is inserting the lead wire into the
terminal window, then
tighten the screw on
the top. (Tightening
torque: 0.25 to 0.35 Nm)

Step 3. Mounting the


terminal block cover
Hook groove (a) on shaft (b) and close
the cover. Then tighten the screws.
(a)

1st row -- 2nd row ------- 3rd row


The quantity of terminal blocks used depends
on the number of manifold stations:

Manifold

08 C6

Series
1
2

2 rows

9 to 12 stations

3 rows
Station 8

As the standard electrical wiring specifications, double wiring (connected to SOL. A and
SOL. B) is adopted for the internal wiring of each station for
12 stations or less, regardless
of valve and option types.
Mixed single and double wiring
is available as semi-standard.
Refer to page 56 for details.

T0
Nil

Plug-in unit

24 Note 1) 24 stations
Note 1) VQ2000: Max. 20 stations
Refer to page 56 for details.
For negative common specifications of series VQ1000, refer
to Semi-standard on page 56.
For series VQ2000 the
standard manifold can be used.

CE compliant

Note) For CE compliant


models, DC-type only.

Stations
Cylinder port
Symbol

Port size

VQ1000 VQ2000

C3 Note 1) With 3.2 One-touch fitting


C4 Note 1) With 4 One-touch fitting
C6 Note 1) With 6 One-touch fitting
C8 Note 1) With 8 One-touch fitting
M5
M5 thread
CM Note 2) Note 3) Mixed sizes and with port plug
MM Note 4) Mixed size for different types of piping, option installed

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to Semi-standard on page 57 for details.
b

33

Station 9
Station 10
Station 11
Station 12

()

SOL.A

1A

()

(+)

SOL.B

1B

()

(+)

SOL.A

2A

()

(+)

SOL.B

2B

()

(+)

SOL.A

3A

()

(+)

SOL.B

3B

()

(+)

SOL.A

4A

()

(+)

SOL.B

4B

()

(+)

SOL.A

5A

()

(+)

SOL.B

5B

()

(+)

SOL.A

6A

()

(+)

SOL.B

6B

()

(+)

SOL.A

7A

()

(+)

SOL.B

7B

()

(+)

SOL.A

8A

()

(+)

SOL.B

8B

()

(+)

SOL.A

9A

()

(+)

SOL.B

9B

()

(+)

SOL.A

10A

()

(+)

SOL.B

10B

()

(+)

SOL.A

11A

()

(+)

SOL.B

11B

()

(+)

SOL.A

12A

()

(+)

SOL.B

12B

()

(+)

COM.

COM

(+)

()

Positive
COM spec.

Negative
COM spec.

Note)

[Option]

Option
Symbol
Nil

CE compliant

2 stations

Station 7

(+)

Note) For CE compliant


models, DC-type only.

Manifold

02

Station 6

Polarity

COM

Note) When using the negative common specifications,


use valves for negative common.
Refer to Semi-standard on page 56 for details.

(b)

VQ1000
VQ2000

Station 5

Terminal block

2 to 8 stations

How to Order Manifold

VV5Q 1 1

0-1
0A-1
-51

Wiring Specifications: VQ1000

Step 1. Removing the terminal block cover

3.5

-51

-51

The total number of


stations is tabulated
starting from station
one on the D-side.

Terminal Block Connection (VQ1000) 


Open the terminal block cover to connect
the wires to the terminal block.

-51

-51

100

00

00

00

00

00

00

13

12

12

VVQ

VQ

VQ

VQ

B Note 2)
D
D0
D Note 6)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
K Note 6)
N
R Note 7)
S
W

Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified (: Stations 02 to 24)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof (IP65)

Note 1) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve
is desired, and is to be installed only in certain manifold stations, specify the mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J
and N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.

Station 2

Loosen mounting screws (4 pcs.) on the terminal block cover


and remove the cover.

Station 3

Step 2. Wiring

Station 4

Cover
Station 5
Station 6
Station 7

As the standard electrical wiring specifications, double wiring (connected to SOL. A and
SOL. B) is adopted for the internal wiring of each station for
10 stations or less, regardless
of valve and option types.
Mixed single and double wiring
is available as semi-standard.
Refer to page 56 for details.

M3 Round head
combination screw

Note) For CE compliant


models, DC-type only.

VQ 1 1 0 0

Station 10

1B

()

(+)

SOL.A

2A

()

(+)

SOL.B

2B

()

(+)

SOL.A

3A

()

(+)

SOL.B

3B

()

(+)

SOL.A

4A

()

(+)

SOL.B

4B

()

(+)

SOL.A

5A

()

(+)

SOL.B

5B

()

(+)

SOL.A

6A

()

(+)

SOL.B

6B

()

(+)

SOL.A

7A

()

(+)

SOL.B

7B

()

(+)

SOL.A

8A

()

(+)

SOL.B

8B

()

(+)

SOL.A

9A

()

(+)

SOL.B

9B

()

(+)

SOL.A

10A

()

(+)

SOL.B

10B

()

(+)

COM.

(+)

Negative
COM spec.

How to Order Manifold Assembly

[Option]

Specify the part numbers for valves and options


together beneath the manifold base part number.

()
Note)

Positive
COM spec.

S kit

Securely tighten the screws after confirming


that the gasket is installed correctly.
(Tightening torque: 0.7 to 1.2 Nm)

How to Order Valves

Station 9

(+)

SOL.B

Note) When using the negative


common specifications,
use valves for negative
common.
Refer to Semi-standard on page
56 for details.

Step 3. Mounting the terminal


block cover
Applicable crimped terminal:
1.25-3S, 1.25Y-3,
1.25Y-3N, 1.25Y-3.5

Station 8

()

P kit

Step 1. Removing the terminal block cover

1A

J kit

Station 1

Polarity

SOL.A

G kit

Terminal no.

Open the terminal block cover to connect


the wires to the terminal block.

Loosen screws on the terminal block,


connect wiring and complete it by
tightening screws.(Tightening torque:
0.5 to 0.7 Nm)
The diagram on the right shows the
terminal block wiring. All stations are
provided with double wiring regardless
of the valves which are mounted.

F kit

Wiring Specifications: VQ2000

T kit

 Special

Block Wiring (VQ2000)

L kit

 Terminal

Series VQ1000/2000

M kit

Base Mounted Plug-in Unit

Enclosure

2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

Nil
W Note)

Dust-protected
Dust-tight, Water-jet-proof
(IP65)

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
4 setsValve part no. (Stations 3 to 6)
1 setValve part no. (Station 7)
1 setBlanking plate part no. (Station 8)

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Note) VQ2000 only

ide

Us

Metal seal
Rubber seal

Sta

-1
0A
0-1 1
00
5
Q1 0VV 30 51
1
0Q
0
V
1
12 -5
0
Q
0
V
51
12
Q 00V
51
12
0VQ 20
51
1
Q 00V
11
Q
V

B
C
D

s
tion

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.

ide
Ds

Manual override
Nil

Seal
0
1

VV5Q11-08C6T0
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

Note) For CE compliant


models, DC-type only.

Type of actuation

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

Light/surge voltage suppressor


Nil

Yes
None

Coil voltage
Function
Symbol Specifications

Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.

DC
(0.4 W)

Nil

Standard

High-speed (0.95 W)
response type
High-pressure type (0.95 W)

K Note 2) (1.0 MPa)

Negative

N Note 3) common
R Note 3)

External
pilot

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

1
2
3
4
5
A
B
C

CE compliant

AC
Note 1)

1 100 VAC (50/60 Hz)


3 110 VAC (50/60 Hz)
24 VDC
5
12 VDC
6

Semistandard

Construction

Nil

VQ1000
VQ2000

Exploded
View of
Manifold

1
2

Terminal block box kit

Sub-plate
Single Unit

<Example>

CE compliant

Series

CE compliant

Note 1) Refer to page 16 for power consumption


of AC type.
Note 2) Metal seal only
Note 3) Refer to Semi-standard on pages 56 to
57 for external pilot and negative common specifications.
Note 4) When two or more symbols are specified, indicate them alphabetically. Combination of [B] and [K] is not possible.

34

VQ-A.qxd

09.2.26 2:36 PM

Page 36

Series VQ1000/2000

kit (Terminal block box)

VV5Q11

< >: AC
The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].

(L4)
(L3)
L2
Top entry port
Not machined

63.5 <67.5>

55
13

L1
P = 10.5

29

13

27

Indicator light

Manual
override

(5.5)

4.5

(12)

(5.25)

40

(35)

93.5 <100.4>
66

4 x M5 mounting hole
2

66
67

D side

Stations

U side

DIN rail clamp screw

C8 [3(R) EXH port]


C8: 8 one-touch fitting

L1
L2
(L3)
(L4)

(7.5)

X
P

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

66.5

77

87.5

98

108.5 119

126

136.5 147

157.5 168

150

162.5 175

187.5 187.5 200

160.5 173

185.5 198

198

129.5 140

178.5 189

11

150.5 161

199.5 210

212.5 225

210.5 223

10

13

171.5 182

220.5 231

237.5 250

235.5 248

12

14

15

192.5 203

16

17

213.5 224

C8 [1(P) SUP port]


C8: 8 one-touch fitting

18.1
31.5

P = 10.5

Formula L1 = 10.5n + 45.5, L2 = 10.5n + 105

18

19

234.5 245

n: Station (Maximum 24 stations)

20

241.5 252

262.5 273

283.5 294

304.5 315

287.5 300

312.5 325

325

273

285.5 298

310.5 323

21

255.5 266

262.5 262.5 275

260.5 273

With ejector unit: Formula L1 = 10.5n + 29.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 88.8 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

35

18.7
(12)
n

9.3
25
40.7
61.5

7.7

G 1/2

Dimensions
L

325.5 336

337.5 350

335.5 335.5 348

22

23

276.5 287

346.5 357

362.5 375

360.5 373

24
297.5
387.5

385.5 398

VQ-A.qxd

09.2.26 2:36 PM

Page 37

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

VV5Q21

(L4)
(L3)
L2
L1

(5.25)

P = 16
0.9

13

34.5
1

6.5

G kit

100

Manual
override

Indicator light

4A

3A

U SIDE

(35)

126
120 <126.9>

(5.5)

T kit

4B

L kit

46.2

S kit

4
10.6
4 x M5 mounting hole
1

U side

M kit

Stations

DIN rail clamp screw


C10 [3(R) EXH port]
C10: 10 one-touch fitting

2 x G 3/4
Electrical entry
EXH

EXH
R

(7.5)
(12)

120 <126.9>
126
80

9.5

4B

2B

3B

1B

23

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
P = 16
C6: 6 one-touch fitting
C8: 8 one-touch fitting

49

41

6.5

Exploded
View of
Manifold

C10 [1(P) SUP port]


C10: 10 one-touch fitting

Dust-tight, Water-jet-proof

Dimensions
n

L1
L2
(L3)
(L4)

Formula L1 = 16n + 118.5, L2 = 16n + 131

n: Station (Maximum 20 stations)

10

11

12

13

14

15

16

17

18

19

20

150.5

166.5

182.5

198.5

214.5

230.5

246.5

262.5

278.5

294.5

310.5

326.5

342.5

358.5

374.5

390.5

406.5

422.5

438.5

163

179

195

211

227

243

259

275

291

307

323

339

355

371

387

403

419

435

451

187.5

200

225

237.5

250

262.5

287.5

300

312.5

337.5

350

362.5

375

400

412.5

425

450

462.5

475

198

210.5

235.5

248

260.5

273

298

310.5

323

348

360.5

373

385.5

410.5

423

435.5

460.5

473

485.5

36

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

4A

TERMINANAL
NO.

3A

2A

1A

U SIDE

D SIDE

STA

46.5
24.5

16
31.6

(L4)
(L3)
L2 + 0.5
L1 + 0.5
100.5

Sub-plate
Single Unit

D side

Semistandard

6.5

76

Construction

3B

1B

2B

TERMINANAL
NO.

1A

2A

D SIDE

STA

80

(12)

J kit

P kit

< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).

Series VQ1000/2000

kit (Lead wire)


3
4
1
2
4
3
2
3

2
1

IP65 compliant

VV5Q11

 Direct electrical entry. Models with one or more stations


are available.
 (SUP) and (EXH) ports are provided on one side for further space savings.
 Maximum stations are 8.
 Enclosure: Dust-tight, Water-jet-proof (IP65) compatible
(Series VQ2000)

Manifold Specifications
Piping specifications
Series

Wiring Specifications: Positive COM 

COM. (+)
SOL.B

()

VQ2000

Side

C10

C3, C4, C6, M5 Max. 8 stations


C6, C8

Max. 8 stations

tio

ns

U
ta
S
3
2

COM. (+)
SOL.B

Single solenoid

C8

()

Black

()

Red
White

Side

Applicable
stations

sid
e

Lead wire color


SOL.A

Black

VQ1000

Lead wire color


()

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)

sid
e

Three lead wires are attached to each station regardless of the


type of valve which is mounted.
The red wire is for COM connection.
SOL.A

VV5Q21

Red
White

Double solenoid
4

Black: A side solenoid ()

1
2
3
4
3
2
3

ns

ta

Station
number

tio

sid

Red: COM (+)

sid

VV5Q11

Cable 3 cores x 24AWG


White: B side solenoid ()
(Not used for single solenoid)
Use any of the below cable lead wire assembly to change the lead wire length:

Lead wire assembly with connector


Lead wire length
0.6 m
1.5 m
3m

Part no.
VVQ1000-84A-6VVQ1000-84A-15VVQ1000-84A-30-

Station number 1 to 8

The total number of stations is


tabulated on the D-side.

Note) For CE compliant


models, DC-type only.

How to Order Manifold

VV5Q 1 1

06 C6

CE compliant
Cable (Length)
0
1
2

Manifold
1

Plug-in unit

Stations
01

Symbol
Nil
Nil

VQ1000
VQ2000

1 station

Cable length 0.6 m


Cable length 1.5 m
Cable length 3 m

CE compliant

Note) For CE compliant


models, DC-type only.

Cylinder port
Symbol

Port size

VQ1000 VQ2000

C3 Note 1) With 3.2 One-touch fitting


With 4 One-touch fitting
C4 Note 1)
8 stations
08
With 6 One-touch fitting
C6 Note 1)
Note) For negative common
With 8 One-touch fitting
C8 Note 1)
specifications, refer to
M5 thread
M5
Semi-standard on
CM Note 2) Note 3) Mixed sizes and with port plug
page 56.
MM Note 4) Mixed size for different types of piping, option installed
Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.
Example) B6 (Bottom ported elbow with 6 One-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
double check block (direct mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size One-touch fittings are available. Refer to Semi-standard on page 57 for details.
c

37

[Option]

Option

Series
1
2

VV5Q21

2
B

Note 2)

D
D0
D Note 3)
G1 Note 4)
G2 Note 4)
G3 Note 4)
J Note 5)
N
R Note 6)
S
W

VQ1000 VQ2000
Option
None
200/220 VAC models
(F/L kit only)
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail length specified (: Stations 02 to 08)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
With name plate
External pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight, Water-jet-proof (IP65)

Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS
Note 2) Models with a suffix -B have check valves for prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain manifold stations, specify the
mounting position by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than the
manifold number of stations.
Note 4) Specify the mounting position by means of the manifold specification sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of
J and N is not available.
Note 6) Indicate R for the valve with external pilot.

Three lead wires are attached to each station regardless of the


type of valve which is mounted.
The black wire is for COM connection.
Lead wire color
Lead wire color
(+)

SOL.A

Red

VV5Q21

(+)

SOL.B

White

Single solenoid

Dust-tight, Water-jet-proof

Red

COM. () Black

COM. () Black
SOL.B

(+)

(+)

White

Double solenoid

G kit

SOL.A

P kit

Specifications: Negative COM (Semi-standard)

J kit

 Wiring

F kit

Series VQ1000/2000

Base Mounted Plug-in Unit

Red: A side solenoid (+)


Black: COM. ()

T kit

Station
number
Cable 3 cores x 24AWG

L kit

White: B side solenoid (+)


(Not used for single solenoid)

Lead wire assembly with connector

Station number 1 to 8

S kit

Part no.
VVQ1000-84AN-6-
VVQ1000-84AN-15-
VVQ1000-84AN-30-

Note) When using the negative common specifications, use valves for negative common. For negative common specifications, refer to Semistandard on page 56.

CE compliant

Type of actuation

Seal

Nil

Metal seal
Rubber seal

CE compliant

Note) For CE compliant


models, DC-type only.

Enclosure

2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

Nil
W Note)

Dust-protected
Dust-tight, Water-jet-proof
(IP65)

Note) VQ2000 only

VV5Q11-06C6L2
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
2 setsValve part no. (Stations 3 to 4)
1 setValve part no. (Station 5)
1 setBlanking plate part no. (Station 6)
Write sequentially from the 1st
station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.
ide

Us

Manual override

s
tion

Sta

ide
Ds
2

Function
DC
(0.4 W)

2
3

Nil

Light/surge voltage suppressor


Yes
None

Negative

N Note 3) common
R Note 3)

External
pilot

Note 1) Refer to page 16 for power consumption of AC type.


Note 2) Metal seal only
Note 3) For external pilot and negative common specifications,
refer to Semi-standard on pages 56 to 57.
Note 4) When two or more symbols are specified, indicate them
alphabetically. Combination of [B] and [K] is not possible.

Coil voltage
1
2
3
4
5
6

100 VAC (50/60 Hz)


200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

CE compliant

Sub-plate
Single Unit

-1

High-pressure type (0.95 W)

K Note 2) (1.0 MPa)

-10A

High-speed (0.95 W)
response type

1000

Note 1)

VVQ

1
2
3

Standard

B
C
D

Nil

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

Nil

AC

1
-5
00 1
-5
12
Q
00 1
V
-5
11
Q
00 1
V
11 0-5
Q
0
1
V
11 0-5
Q
0
V
11
Q
V

Symbol Specifications

1
2
3
4
5
A
B
C

0
1

VQ1000
VQ2000

<Example>
Lead wire kit with cable (3 m)

Semistandard

Series
1
2

Specify the part numbers for valves and options


together beneath the manifold base part number.

Construction

1 0 0

How to Order Manifold Assembly

Exploded
View of
Manifold

VQ 1

[Option]

Caution
Use the standard (DC) specification when
continuously energizing for long periods
of time.

38

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Note) For CE compliant


models, DC-type only.

How to Order Valves

M kit

Lead wire length


0.6 m
1.5 m
3m

VQ-A.qxd

09.2.26 2:36 PM

Page 40

Series VQ1000/2000
kit (Lead wire)

VV5Q11

< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).

(L4)
(L3)
L2
L1
28

63.5 <67.5>
(12)

(5.25)

P = 10.5

13

11.2

Manual
override

Indicator light

A
3 2 1

40.5

(35)

3 2 1

3 2 1

93.5 <100.4>
66

Number of
stations

(5.5)

1.5

Lead wire
AWG24 x 3 cores

4 x M4 mounting hole
61.5

D side

Stations

U side

C8 [3(R) EXH port]


C8: 8 one-touch fitting

7.7

20
33.3

C8 [1(P) SUP port]


C8: 8 one-touch fitting

(7.5)

18.7

(12)

40.7
25
9.3

DIN rail clamp screw

P = 10.5
C3, C4, C6, M5 [4(A), 2(B) port]
C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

Formula L1 = 10.5n + 28.5, L2 = 10.5n + 38


n: Station (Maximum 8 stations)

Dimensions
n

L1
L2
(L3)
(L4)

70.5

81

91.5

39

49.5

60

48.5

59

69.5

80

90.5

75

87.5

87.5

100

112.5

85.5

98

98

110.5

123

112.5

101

111.5

122

125

137.5

150

135.5

148

160.5

With ejector unit: Formula L1 = 10.5n + 28.5 + (Number of ejector units x 26.7)
L2 = 10.5n + 38 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

39

102

Page 41

VV5Q21

(L4)
(L3)
L2
L1

Number of
stations

73.5 <77.5>
13

(5.25)
5.5

J kit

34.5
0.9

P kit

< >: AC
The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).

Lead wire
AWG24 x 3 cores

Manual override
Indicator light
4 x M5 mounting hole

S kit

10.6
4

46.2

L kit

(35)

120 <126.9>
80

(5.5)

G kit

16.5
1

Dust-tight, Water-jet-proof
1

U side

M kit

Stations

Sub-plate
Single Unit

D side

C10 [3(R) EXH port]


C10: 10 one-touch fitting
EXH

Semistandard

Construction

49
31.6
24.5
16

DIN rail clamp screw


B

9.5
(7.5)

(12)
C10 [1(P) SUP port]
C10: 10 one-touch fitting

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting
C8: 8 one-touch fitting

23
41

P = 16

Formula L1 = 16n + 35, L2 = 16n + 47


n: Station (Maximum 8 stations)

Dimensions
n

L1
L2
(L3)
(L4)

Exploded
View of
Manifold

(12)

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

T kit

09.2.26 2:36 PM

51

67

83

99

115

131

147

163

63

79

95

111

127

143

159

175

87.5

100

125

137.5

150

162.5

184.5

200

98

110.5

135.5

148

160.5

173

198

210.5

40

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

VQ-A.qxd

Series VQ1000/2000

kit (Serial transmission) Base mounted plug-in manifold: For EX510 Gateway-type serial transmission system

How to Order Manifold

VV5Q 1 1 SB

08

CE compliant

Manifold series
1
2

Nil

VQ1000

VQ2000

NPN output (+COM.)

PNP output (COM.)

Valve stations
Symbol Stations

01

SI unit part no.


Symbol SI unit specifications SI unit part no.
Nil NPN output (+COM.) EX510-S002A

PNP output (COM.)

EX510-S102A

08

1 station
8 stations

Note) Max. 16 stations.


(Special wiring
specifications)

Cylinder port
Symbol

Inch size

Metric size

C3
C4
C6
C8
M5
CM Note 1)
L3
L4
L6
L8
L5
B3
B4
B6
B8
B5
LM Note 1)
N1
N3
N7
N9
M5T
NM Note 1)
LN1
LN3
LN7
LN9
L5T
BN1
BN3
BN7
BN9
B5T
LNM Note 1)
MM Note 2)

Port size

VQ1000 VQ2000

With 3.2 One-touch fitting


With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
M5 thread
With mixed sizes and with port plug
Top ported elbow with 3.2 One-touch fitting
Top ported elbow with 4 One-touch fitting
Top ported elbow with 6 One-touch fitting
Top ported elbow with 8 One-touch fitting
Top ported elbow M5 thread
Bottom ported elbow with 3.2 One-touch fitting
Bottom ported elbow with 4 One-touch fitting
Bottom ported elbow with 6 One-touch fitting
Bottom ported elbow with 8 One-touch fitting

D Note 1)
B Note 3)
D Note 9)
G1 Note 4) Note 8)
G2 Note 4) Note 8)
G3 Note 4) Note 8)
J Note 5) Note 8)
K Note 6)
N
R Note 7)
S

DIN rail mounting


With back pressure check valve
DIN rail length specified (: Stations 02 to 16)
1 set of regulator unit
2 sets of regulator unit
3 sets of regulator unit
With ejector unit
Special wiring spec. (Except double wiring)
With name plate
With external pilot
Direct EXH outlet with built-in silencer

Note 1) Be sure to select D or D.


Note 2) When two or more symbols are specified, indicate them alphabetically.
Example) -BRS
Note 3) Models with a suffix -B have check valves for prevention of back
pressure at all manifold stations. When a back pressure check valve is
desired, and is to be installed only in certain manifold stations, specify
the mounting position by means of the manifold specification sheet.
Note 4) Specify the mounting position by means of the manifold specification
sheet.
Note 5) Refer to page 69 for details on with ejector unit. A combination of J
and N is not available.
Note 6) Specify the wiring specifications by means of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.
Note 8) VQ1000 only
Note 9) The number of stations that may be displayed is longer than the manifold number of stations.

How to Order Manifold Assembly

Bottom ported elbow M5 thread


Elbow port, mixed sizes (Including upward, downward piping and mixed)
1/8" with One-touch fitting
5/32" with One-touch fitting
1/4" with One-touch fitting

Example

ide

Us

ns

tio
Sta

ide

Ds

5/16" with One-touch fitting


UNF10-32 thread
With mixed sizes and with port plug
Top ported elbow with 1/8" One-touch fitting
Top ported elbow with 5/32" One-touch fitting
Top ported elbow with 1/4" One-touch fitting
Top ported elbow with 5/16" One-touch fitting
Top ported elbow UNF10-32 thread
Bottom ported elbow with 1/8" One-touch fitting
Bottom ported elbow with 5/32" One-touch fitting
Bottom ported elbow with 1/4" One-touch fitting
Bottom ported elbow with 5/16" One-touch fitting
Bottom ported elbow UNF10-32 thread
Elbow port, mixed sizes (Including upward, downward piping and mixed)
Mixed size for different types of piping, option installed

Note 1) Indicate Mixed sizes and with port plug in the manifold specification sheet.
Note 2) When selecting the mixed size for different types of piping, dual flow fitting
assembly, or double check block (direct mounting), enter MM and give
instructions in the manifold specification sheet.

Refer to Best Pneumatics No. q for details on EX510 gatewaytype serial transmission system.

41

CE compliant

Option

SI unit specifications
Nil

[Option]

VV5Q11-SB08C6-D

VQ1100-51
VQ1200-51
VQ1300-51

1 set (SB kit, 8-station manifold part no.)


4 sets (Single type part no.)
3 sets (Double type part no.)
1 set (3 position type part no.)

The asterisk denotes the symbol for assembly. Prefix it to the part
nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D-side.
Add the valve and option part numbers under the manifold base part number. In the case
of complex arrangement, specify them by means of the manifold specification sheet.

Series VQ1000/2000

How to Order Valves

VQ 1 1 0 0

[Option]

1
Nil

VQ1000
VQ2000

CE compliant

Manual override

G kit

1
2

J kit

CE compliant

Series

Nil: Non-locking
push type
(Tool required)

Type of actuation

2-position single

P kit

F kit

Base Mounted Plug-in Manifold

T kit

B: Locking type

Metal

2-position double

L kit

2-position double

C: Locking type

S kit

Rubber

(Tool reguired)

(Manual)

3-position closed center

M kit

3
3-position exhaust center

D: Slide locking type

Sub-plate
Single Unit

(Manual)

3-position pressure center

3
N.O.

24 VDC

Function

4-position dual 3-port valve


(C)
4
2
5
N.C.

Semistandard

Rated voltage

4-position dual 3-port valve


(B)
4
2
5
N.O.

Note)

3
N.C.

Construction

Note)

Symbol

Specifications

Nil

Standard (0.4 W)

Exploded
View of
Manifold

5
N.C.

High-speed response type (0.95 W)


B
K Note 1) High-pressure type (1.0 MPa) [0.95 W]
Negative common
N Note 2)
External pilot
R Note 2)

3
N.O.

Note) Rubber seal only

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

A Note)

4-position dual 3-port valve


(A)
4
2

Note 1) Metal seal only


Note 2) For external pilot and negative common specifications, refer to Semi-standard on pages 56 to 57.
Note 3) When two or more symbols are specified, indicate
them alphabetically. Combination of [B] and [K] is
not possible.

Seal
0
1

Metal seal
Rubber seal

42

VQ-A.qxd

09.2.26 2:36 PM

Page 44

Series VQ1000/2000
kit (Serial transmission) Base mounted plug-in manifold: For EX510 Gateway-type serial transmission system

VV5Q11
L4
L3
L2

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)

33
8.8

L1
(n-1) x 10.5
10.5

28

63.5
13

27

Indicator light

A
0
1

PWR

COM

40

8
9

5.5
35

6
7

93.5
66

14
15

35

Manual
override

(12)

5.25

52
61.5

D side

Stations 1

U side

C8 [3(R) EXH port]


C8: 8 one-touch fitting

DIN rail clamp screw

43

X
P

9.3

7.5

L1
L2
L3
L4

12 18.7
n

C3, C4, C6, M5 [4(A), 2(B) port]


C3: 3.2 one-touch fitting
P = 10.5
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

Dimensions
L

25
40.7

7.7

18.1
31.5

C8 [1(P) SUP port]


C8: 8 one-touch fitting

Formula L1 = 10.5n + 44.5, L2 = 10.5n + 91

10

11

12

n: Station (Maximum 16 stations)

13

55

65.5

76

86.5

97

107.5

118

128.5

139

149.5

160

170.5

181

191.5

14

202

15

212.5

16

101.5

112

122.5

133

143.5

154

164.5

175

185.5

196

206.5

217

227.5

238

248.5

259

125

137.5

150

162.5

175

175

187.5

200

212.5

225

237.5

237.5

250

262.5

275

287.5

135.5

148

160.5

173

185.5

185.5

198

210.5

223

235.5

248

248

260.5

273

285.5

298

VQ-A.qxd

09.2.26 2:36 PM

Page 45

Series VQ1000/2000

F kit

Base Mounted Plug-in Manifold

P kit

VV5Q21
L4
L3
L2

6.5

34.5

P = 16
0.9

Indicator light

34.5
Manual
override

8
9

L kit
Stations

U side

M kit

D side

Sub-plate
Single Unit

DIN rail clamp screw


C10 [3(R) EXH port]
C10: 10 one-touch fitting

EXH
R

7.5

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting P = 16
C8: 8 one-touch fitting

Exploded
View of
Manifold

12 16
31.6
49

Semistandard

EXH
R

23
41
C10 [1(P) SUP port]
C10: 10 one-touch fitting

Dimensions
n

L1
L2
L3
L4

Formula L1 = 16n + 53, L2 = 16n + 101

Construction

52

n: Station (Maximum 16 stations)

10

11

12

13

14

15

16

69

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

117

133

149

165

181

197

213

229

245

261

277

293

309

325

341

357

137.5

162.5

175

187.5

212.5

225

237.5

250

275

287.5

300

312.5

337.5

350

362.5

387.5

148

173

185.5

198

223

235.5

248

260.5

285.5

298

310.5

323

348

360.5

373

398

44

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

35

S kit

10.6
4

PWR

COM

46.2

35

80

120

14
15

5.5

13

J kit

L1
8.5

G kit

33

73.5
(12)

(5.25)

T kit

Applicable connector: Flat ribbon cable connector (20P)


(Complies with MIL-C-83503)

Series VQ1000/2000

kit (Serial transmission): For EX120/123/124 Integrated-type (Output) serial transmission system

IP65 compliant

Manifold Specifications

The serial transmission system reduces wiring work,


while minimizing wiring and saving space.
Enclosure: Dust-tight, Water-jet-proof (IP65) compatible
(Series VQ2000)

Piping specifications
Series

Applicable
stations

Port size
Piping
direction 1(P), 3(R)
4(A), 2(B)

VQ1000

Side

C8

VQ2000

Side

C10

C3, C4, C6, M5 Max. 16 stations


Max. 16 stations

C4, C6, C8

How to Order Manifold

VV5Q 1 1

08 C6

SV

XP
CE compliant

Series
1
2

Enclosure

VQ1000
VQ2000

Nil

XP Note)

Plug-in unit

Stations
02

2 stations

16 Note)

16 stations

Note 1) Refer to page 56 for


details.
Note 2) Max. 16 stations. (Specify
a model with 9 to 16
stations by means of the
manifold specification
sheet.)

C3 Note 1)
C4 Note 1)
C6 Note 1)
C8 Note 1)
M5
CM Note 2) Note 3)
MM Note 4)

Symbol

0
F1
H
J1
J2
Q
R1
R2
V
ZB
ZBN

F1
H
J1
J2
Q
R1
R2
V
ZB
ZBN

Stations

Protocol

Without SI unit
NKE Corp.: Fieldbus System
Max.16
stations
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
Max. 8 stations
SUNX Corp.: S-LINK (8 outputs)
DeviceNet System
Max.16
OMRON Corp.: CompoBus/S (16 outputs) stations
OMRON Corp.: CompoBus/S (8 outputs) Max. 8 stations
CC-LINK
Max.16
CompoNet (Positive common)
stations
CompoNet (Negative common)
Note 1) Insert L (Top ported) or B (Bottom
ported) for elbow type.
Example) B6 (Bottom ported elbow
with 6 one-touch fitting)
Note 2) Indicate as LM for models with elbow
fittings and mixed cylinder port sizes.
Note 3) Indicate Mixed sizes and with port
plug by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or double check block (direct
mounting), enter MM and give instructions in the manifold specification sheet.
Note 5) Inch-size one-touch fittings are available. Refer to Semi-standard on page
included.]) 57 for details.

Port size
VQ1000 VQ2000
With 3.2 one-touch fitting
With 4 one-touch fitting
With 6 one-touch fitting
With 8 one-touch fitting
M5 thread
Mixed sizes and with port plug
Mixed size for different types
of piping, option installed

SI Unit Part No.


(Without option W [Dust-protected (-XP) is
Symbol

Refer to SI Unit Part No.


when ordering the CEcompliant SI unit.

Protocol

CE compliant
SI unit part no.
Standard: EX120-SUW1
Dust-protected: EX120-SUW1-XP
Standard: EX120-SUH1
NKE Corp.: Fieldbus H System
Dust-protected: EX120-SUH1-XP
Standard: EX120-SSL1
SUNX Corp.: S-LINK
(16 outputs)
Dust-protected: EX120-SSL1-XP
Standard: EX120-SSL2
SUNX Corp.: S-LINK
(8 outputs)
Dust-protected: EX120-SSL2-XP
Standard: EX120-SDN1
DeviceNet
Dust-protected: No part no.
OMRON Corp.: CompoBus/S Standard: EX120-SCS1
(16 outputs)
Dust-protected: EX120-SCS1-XP
OMRON Corp.: CompoBus/S Standard: EX120-SCS2
(8 outputs)
Dust-protected: EX120-SCS2-XP
Standard: EX120-SMJ1
CC-LINK
Dust-protected: EX120-SMJ1-XP
Standard: EX120-SCM1
CompoNet (Positive common)
Dust-protected: No part no.
Standard: EX120-SCM3
CompoNet (Negative common)
Dust-protected: No part no.
NKE Corp.: Fieldbus System

Symbol
Nil

B Note 2)
D
D Note 3)

Option
VQ1000 VQ2000
None
With back pressure check valve
DIN rail mounting
DIN rail mounting
(: Stations 02 to 24)

G1 Note 4) 1 set of regulator unit


G2 Note 4) 2 sets of regulator unit
G3 Note 4) 3 sets of regulator unit
With ejector unit
J Note 5)
K Note 6) Special wiring specifications
N
R Note 7)
S
8)
W Note
Note 9)

(Except double wiring)


With name plate
With external pilot
Direct EXH outlet with built-in silencer
Enclosure: Dust-tight,
Water-jet-proof (IP65)

Note 1) When two or more symbols are specified,


indicate them alphabetically.
Example) -BRS.
Note 2) Models with a suffix -B have check valves for
prevention of back pressure at all manifold stations. When a back pressure check valve is desired, and is to be installed only in certain
manifold stations, specify the mounting position
by means of the manifold specification sheet.
Note 3) The number of stations that may be displayed
is longer than the manifold number of stations.
Note 4) Specify the mounting position by means of
the manifold specification sheet.
Note 5) Refer to page 69 for details on with vacuum
ejector unit. A combination of J and N is
not available.
Note 6) Specify the wiring specifications by means
of the manifold specification sheet.
Note 7) Indicate R for the valve with external pilot.
Note 8) A combination of W and XP is unavailable.
Note 9) Refer to Dimensions on page 48 for SI unit
and valve, in case of W (Dust-tight, Water-jetproof).

SI Unit Part No. (With option W)


Symbol

F1
H
J1
J2
Q
R1
R2
V

Protocol
NKE Corp.: Fieldbus System
NKE Corp.: Fieldbus H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet System
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK

SI unit part no. CE compliant


EX123D-SUW1
EX123D-SUH1
EX123D-SSL1
EX123D-SSL2
EX124D-SDN1
EX124D-SCS1
EX124D-SCS2
EX124D-SMJ1

Refer to Best Pneumatics No. q for details on the EX120/123/124 integrated-type (Output) serial transmission system.
Refer to SMC Information (08-E543) for details on CompoNet.

45

CE compliant

Option
SI unit specifications

Cylinder port
Symbol

Note) Suffix -XP for the dust-protected type SI units


(Except SI unit specification Q)

Manifold
1

Nil

Dust-protected

Base Mounted Plug-in Unit

Series VQ1000/2000

VV5Q21

Dust-protected (-XP)

Dust-tight, Water-jet-proof (-W)

How to Order Valves

[Option]

VQ 1 1 0 0

Specify the part numbers for valves and options


together beneath the manifold base part number.

1
CE compliant

Series

Nil

VQ1000
VQ2000

CE compliant

Enclosure
Nil

Type of actuation
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

W Note)

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

Note) VQ2000 only

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.

ide

Us

Metal seal
Rubber seal

S kit

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

ide

Ds

VVQ
1000
VQ
-10A
130
VQ
-1
0-5
12
VQ
1
120 00-51
VQ
0-5
120
1
0-5
1
2
VQ
1
00-5
11
VQ
1
110 00-51
0-5
1
VQ

M kit

B
C
D

Nil

ta

tio

ns

Manual override

Seal

Coil voltage
24 VDC;
With indicator light/
surge voltage suppressor

Sub-plate
Single Unit

Function
Nil

Standard

DC
(0.4 W)

Semistandard

Symbol Specifications

High-speed (0.95 W)
response type

Construction

HighK Note 1) pressure type (0.95 W)


Negative
common

R Note 2

External
pilot

Exploded
View of
Manifold

(1.0 MPa)
Note 2)

Note 1) Metal seal only


Note 2) For external pilot and negative
common specifications, refer to
Semi-standard on pages 56 to 57.
Note 4) When two or more symbols are
specified, indicate them alphabetically. Combination of [B] and [K] is
not possible.

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

0
1

Dust-protected
Dust-tight, Water-jet-proof
(IP65)

1 setManifold base part no.


2 setsValve part no. (Stations 1 to 2)
4 setsValve part no. (Stations 3 to 6)
1 setValve part no. (Station 7)
1 setBlanking plate part no. (Station 8)

1
2
3
4
5
A
B
C

<Example>
VV5Q11-08C6SV
VQ1100-51
VQ1200-51
VQ1300-51
VVQ1000-10A-1

1
2

How to Order Manifold Assembly

G kit

VV5Q11

T kit

VV5Q21

VV5Q11

L kit

G 1/2 prepared hole

J kit

P kit

F kit

G 1/2

46

VQ-A.qxd

09.2.26 2:36 PM

Page 48

Series VQ1000/2000
kit (Serial transmission): For EX120 Integrated-type (Output) serial transmission system
The dashed lines indicate DIN rail
mounting [-D] (with DIN rail
mounting bracket).

L7
L6
L5

VV5Q11

(L1)
(n-1) x 10.5

28
1.5

A
-

T/R
ERR
1

+
FG

SC (SI No.EX120-STA1)

DIP SW.

MODEL

66
64

RUN

93.5

0V

SERIAL UNIT

SMC

24V

Drawing shows a SC case.


(general purpose type)

Dust-protected SI unit
(L4)
(L3)
L2

63.5
(12)

23.5
1.5

13

(5.25)

L1
(n-1) x 10.5
10.5

28

Indicator light

27

Manual override

A
DIP SW.

FG

SC (SI No.EX120-STA1)

2
4.5

MODEL

(5.5)

T/R
ERR

(35)

RUN

93.5

0V

SERIAL UNIT

66
64

SMC

24V

61.5

4 x M4 mounting hole

Drawing shows a SC case.


D side

Stations

U side

C8 [3(R) EXH port]


C8: 8 one-touch fitting

(12) 18.7
7.7

47

9.3

(7.5)
n

C3, C4, C6, M5 [4(A), 2(B) port]

P = 10.5

18
31.5

C8 [1(P) SUP port]


C8: 8 one-touch fitting

C3: 3.2 one-touch fitting


C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

Dust-protected SI unit: L5 = 10.5n + 97, L6 = L3 + 25, L7 = L4 + 25


Formula L1 = 10.5n + 44.5, L2 = 10.5n + 72.5 n: Station (Maximum 16 stations)

Dimensions
L1
L2
(L3)
(L4)

With ejector unit: Formula


L1 = 10.5n + 28.7 + (Number of ejector units x 26.7)
L2 = 10.5n + 56.3 + (Number of ejector units x 26.7)
L4 is L2 plus about 30.

DIN rail clamp screw

25
40.7

65.5

76

86.5

97

107.5

118

128.5

139

149.5

10

160

11

170.5

12

181

13

191.5

14

202

15

212.5

16

93.5

104

114.5

125

135.5

146

156.5

167

177.5

188

198.5

209

219.5

230

240.5

125

125

137.5

150

162.5

175

187.5

187.5

200

212.5

225

237.5

250

250

262.5

135.5

135.5

148

160.5

173

185.5

198

198

210.5

223

235.5

248

260.5

260.5

273

10.7.16 11:44 AM

Page 1

Base Mounted Plug-in Unit

Series VQ1000/2000

The dashed lines indicate DIN rail mounting [-D] (with DIN rail mounting bracket).

L11 = L4 + 50
L10 = L3 + 50
L9 = 16n + 131

82

P kit

L7 = L4 + 25
L6 = L3 + 25
L5 = 16n + 108
L1
34.5
(n-1) x 16

J kit

VV5Q21

G kit
L kit

Dust-tight, Water-jet-proof (IP65) SI unit


(EX123/124 Integrated-type (output) serial transmission system)
(L4)
(L3)
L2
L1
(n-1) x 16

34.5
1

73.5

T kit

100
L8 = 16n + 118.5

(5.25)

34.5
P = 16

6.5
1

13

S kit

FG

(SI No.EX124-SMB1)

DIP SW.

SC (SI No.EX120-STA1)

46.2

MODEL SB

MODEL

ERR. RD SD RUN POWER

T/R
ERR

120
80

x 10

RUN

10.6
4

x1

0V

SERIAL UNIT

Drawing shows a SC case.

Dust-protected SI unit

(12)

STATION NO.

SERIAL UNIT

SMC

24V

EX123: 2 x G1/2
EX124: 4 x G1/2
Electrical entry
Use a drip proof plug assy
(AXT100-B04A) on the
unused conduit port (G1/2).

F kit

286-VQ-CT.qxd

Indicator light

0.9

Sub-plate
Single Unit
Semistandard

FG

46.2

DIP SW.

SC (SI No.EX120-STA1)

D side

Stations

Construction

MODEL

4 x M5 mounting hole

Drawing shows a SC case.

U side

C10 [3(R) EXH port]


C10: 10 one-touch fitting
EXH

24.5

16
31.6
49

9.5

DIN rail clamp screw

(7.5)

(12)

L1
L2
(L3)
(L4)

23

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting
C8: 8 one-touch fitting

P = 16

41

C10 [1(P) SUP port]


C10: 10 one-touch fitting

Dust-protected SI unit: L5 = 16n + 108, L6 = L3 + 25, L7 = L4 + 25


Dust-tight, Water-jet-proof SI unit: L8 = 16n + 118.5, L9 = 16n + 131
L10 = L3 + 50, L11 = L4 + 50
Formula L1 = 16n + 53, L2 = 16n + 83 n: Station (Maximum 16 stations)

Dimensions
L

Exploded
View of
Manifold

EXH
R

10

11

12

13

14

15

16

85

101

117

133

149

165

181

197

213

229

245

261

277

293

309

115

131

147

163

179

195

211

227

243

259

275

291

307

323

339

137.5

162.5

175

187.5

200

225

237.5

250

262.5

287.5

300

312.5

337.5

350

362.5

148

173

185.5

198

210.5

235.5

248

260.5

273

298

310.5

323

348

360.5

373

48

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

T/R
ERR

(35)

RUN

120
80

0V

SERIAL UNIT

10.6
4

SMC

24V

(5.5)

M kit

Manual override

Series VQ2000
kit (Serial transmission): For EX240 Integrated-type (I/O) serial transmission system

IP65 compliant

VQ2000 only
 The serial transmission system reduces wiring work, while
minimizing wiring and saving space.

How to Order Manifold

VV5Q21

[Option]

08 C6

SD

QW 1

N W
CE compliant

VQ2000
Plug-in series

Nil

Stations
01

Enclosure
IP65 (Dust-tight, Water-jet-proof)

1 station

16 16 stations

Option
Option
None
With back pressure check valve
Special wiring spec. (Except double wiring)
With name plate
External pilot

Symbol
Nil

Cylinder port
Symbol

CE compliant

B
K
N
R

Port size

With 4 One-touch fitting


C4 Note 1)
SI unit mounting
With 6 One-touch fitting
C6 Note 1)
D: D side
With 8 One-touch fitting
C8 Note 1)
mounting
Note
2)
Note
3)
Mixed sizes and with port plug
CM
MM Note 4) Mixed size for different types of piping, option installed

Note) When two or more symbols are specified,


indicate them alphabetically.
Example: -BNR

Note 1) Insert L (Top ported) or B (Bottom ported) for


elbow type.
Example) B6 (Bottom ported elbow with 6 one-touch
fitting)
Note 2) Indicate LM for models with elbow fittings and mixed
cylinder port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of
the manifold specification sheet.
Note 4) When selecting the mixed size for different types of
piping, dual flow fitting assembly, or double check
block (direct mounting), enter MM and give instructions in the manifold specification sheet.
Note 5) Inch-size one-touch fittings are available. Refer to
Semi-standard on page 57 for details.

DI unit specifications
Nil

PNP sensor input (+COM) or without SI/DI unit


NPN sensor input (COM)

Number of DI unit
Nil

0
1
2
3
4

Without SI unit or DI unit


DI unit: None
DI unit: 1 pc.
DI unit: 2 pcs.
DI unit: 3 pcs.
DI unit: 4 pcs.

Model

Refer to Best Pneumatics No. q for details on the


EX240 integrated-type (I/O) serial transmission
system.

0W Without SI unit
QW DeviceNet
NWN PROFIBUS-DP

+COM.
COM.

Note) Only +COM is available for DeviceNet.


Order a mounting valve with +COM.
Since PROFIBUS is COM only, order
COM for valves to be mounted.

How to Order Manifold

VQ 2 1 0 0

W1
Enclosure
IP65 (Dust-tight, Water-jet-proof)

Seal
0
1

Manual override

Metal seal
Rubber seal

Nil

B
C
D

Type of actuation
1
2
3
4
5
A
B
C

2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
4-position dual port (N.C. +N.C.)
4-position dual port (N.O. +N.O.)
4-position dual port (N.C. +N.O.)

49

Nil

CE compliant

Refer to SI Unit Part


No. when ordering the
CE-compliant SI unit.

Coil voltage
Function
Symbol

Specifications

Nil

Standard

B
K Note 1)

Note) For external pilot and


negative common
specifications, refer to
Semi-standard on
pages 56 to 57.

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

CE compliant

N Note 2)
R Note 2)

DC

24 VDC; With indicator light/surge


voltage suppressor

(0.4 W) Note 1) Metal seal only

Note 2) For external pilot and negative


common specifications, refer to
Semi-standard on pages 56 to 57.
Note 3) When a valve is compatible with
High-pressure type (0.95 W)
PROFIBUS DP, the SI unit is
(1.0 MPa)
negative common. Select valves for
negative common.
Negative
Note 4) When two or more symbols are speccommon
ified, indicate them alphabetically.
External
Combination of [B] and [K] is not pospilot
sible.

High-speed
response type

(0.95 W)

Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.

VQ-A.qxd

09.2.26 2:36 PM

Page 51

Series VQ2000

F kit

Base Mounted Plug-in Unit

VV5Q21
L2 (In case of 1 pc. input block: 8 number of inputs)
L1
(143)

8.1

54
Min. 0 to
Max. 4 unit
(0 to 216 mm)

P = 16
0.9

34.5

6.5
16.5

J kit

14.6

P kit

(Serial transmission kit: EX240)

Manual override

4 x M5 mounting hole

L kit

10.5
4

Input block
D side

Stations

U side

S kit

If the input block is attached,


it comes with a bracket

T kit

80
120

120

G kit

Indicator light

23

C10 [3(R) EXH port]


C10: 10 one-touch fitting
EXH

M kit

Sub-plate
Single Unit

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting
C8: 8 one-touch fitting

23

P = 16

Semistandard

41
C10 [1(P) SUP port]
C10: 10 one-touch fitting

Formula L1 = 16n + 36.5 L2 = 16n + 186 (In case of 1 pc. DI unit, 54 mm will be added for increasing every 1 pc.)
n: Station (Maximum 24 stations)

Dimensions
L1
L2

68.5

84.5 100.5 116.5 132.5 148.5 164.5 180.5 196.5 212.5 228.5 244.5 260.5 276.5 292.5 308.5 324.5 340.5 356.5 372.5 388.5 404.5 420.5

218

234

4
250

5
266

6
282

7
298

8
314

9
330

10
346

11
362

12
378

13
394

14
410

15
426

16
442

17
458

18
474

19
490

20
506

21
522

22
538

23
554

24
570

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Construction

Exploded
View of
Manifold

1.6

16
24.5
49
73.7

9.5
13.2

75.5
61.5

50

Series VQ2000
kit (Circular connector)
VQ2000 only
VV5Q21

 MIL flat cable connector reduces installation labor for electrical


connection.
 Manifold and connectors, both compliant with the IP65 rating
(Dust-tight, Water-jet-proof), provide a high-degree of protection for the electrical parts.
 Maximum stations are 24.

Manifold Specifications
Piping specifications
Applicable
stations

Series

Piping
direction

1(P), 3(R)

4(A), 2(B)

VQ2000

Side

C10

C4, C6, M8

Port size

Max. 24 stations

Circular Connector (26 Pins)


Cable Assembly 
015

AXT100-MC26- 030

Circular connector cable


assembly terminal no.

050

Circular connector cable assembly included in a specific manifold model no.


Refer to How to Order Manifold.
Multi-core vinyl cable
0.3 mm2 x 25 cores

10

Circular connector cable assembly


Cable length
Assembly part no.
Note
(L)
AXT100-MC26-015
1.5 m
Cable 25-core
AXT100-MC26-030
3m
x 24AWG
AXT100-MC26-050
5m
Cannot be used for transfer wiring.

Electrical characteristics
Item
Property
Conductor resistance 65
/km, 20C or less
Voltage limit
V, 1 min, AC

1000

Insulation resistance
5
M/km, 20C or more

60

Note) The minimum


bending radius of
the circular
connector cable
is 20 mm.

30

Plug terminal no.


1

2
3

13
23

26

19

14

24

25

18

15
16

17

20

12

22

11

21

10
7

Terminal no. Lead wire color Dot marking


1
None
Black
2
None
Brown
3
None
Red
4
None
Orange
5
None
Yellow
6
None
Pink
7
None
Blue
8
White
Purple
9
Black
Gray
10
Black
White
11
Red
White
12
Red
Yellow
13
Red
Orange
14
Black
Yellow
15
Black
Pink
16
White
Blue
17
None
Purple
18
None
Gray
19
Black
Orange
20
White
Red
21
White
Brown
22
Red
Pink
23
Red
Gray
24
White
Black
25
None
White
26
None
White

Socket side

Note) Lengths other than the above are also available. Please contact SMC for details.

Note) For CE compliant


models, DC-type only.

How to Order Manifold

VV5Q 2 1

08 C6

N W
CE compliant

Series
2

Enclosure
IP65 (Dust-tight, Water-jet-proof)

VQ2000

Plug-in unit

Cable (Length)
Cylinder port
Symbol

Stations
02

2 stations

24 24 stations
Note) Refer to
page 56
for details.

51

Nil

CE compliant

Note) For CE compliant


models, DC-type only.

Option

Manifold
1

[Option]

C4 Note 1)
C6 Note 1)
C8 Note 1)
CM Note 2) Note 3)
MM Note 4)

Port size
With 4 One-touch fitting
With 6 One-touch fitting
With 8 One-touch fitting
Mixed sizes and with port plug
Mixed size for different types of piping, option installed

0
1
2
3

Without cable
With cable (1.5 m)
With cable (3 m)
With cable (5 m)

Note 1) Insert L (Top ported) or B (Bottom ported) for elbow type.


Example) B6 (Bottom ported elbow with 6 one-touch fitting)
Note 2) Indicate LM for models with elbow fittings and mixed cylinder
port sizes.
Note 3) Indicate Mixed sizes and with port plug by means of the
manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping,
dual flow fitting assembly, or double check block (direct
mounting), enter MM and give instructions in the manifold
specification sheet.
Note 5) Inch-size one-touch fittings are available. Refer to Semistandard on page 57 for details.

Symbol
Nil

B Note 2)
D
D0
D Note 3)
K Note 4)
N
R Note 5)

Option
None
With back pressure check valve
DIN rail mounting
With DIN rail bracket (Without DIN rail)
DIN rail mounting (: Stations 02 to 24)
Special wiring spec. (Except double wiring)
With name plate
External pilot

Note 1) When two or more symbols are specified, indicate them


alphabetically. Example) -BKR
Note 2) Models with a suffix -B have check valves for prevention of
back pressure at all manifold stations. When a back pressure
check valve is desired, and is to be installed only in certain
manifold stations, specify the mounting position by means of
the manifold specification sheet.
Note 3) The number of stations that may be displayed is longer than
the manifold number of stations.
Note 4) Specify the wiring specifications by means of the manifold
specification sheet.
Note 5) Indicate R for the valve with external pilot.

Series VQ2000

Station 2

VV5Q21

16

24

13

21

Station 3

3
18

19

Station 4
Station 5

SOL.B
SOL.A

6
9

SOL.B
SOL.A

20

10

The total number of stations is tabulated starting from station


one on the D-side.

SOL.B
SOL.A

17

26

22

11

25

23

12

15

14

SOL.B
SOL.A

Station 6

SOL.B
SOL.A

Station 7

SOL.B
SOL.A

Station 8

As the standard electrical wiring


specifications, double wiring (connected to SOL. A and SOL. B) is
adopted for the internal wiring of
each station for 12 stations or less,
regardless of valve and option types.
Mixed single and double wiring is
available as semi-standard. Refer to
page 56 for details.

SOL.B
SOL.A

Station 9

SOL.B
SOL.A

Station 10

SOL.B
SOL.A

Station 11

SOL.B
SOL.A

Station 12
(Max.)

SOL.B
COM.
COM.

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26

Positive
COM spec.

Note) When using the negative common


specifications, use valves for negative common.
(Refer to page 56.)
Refer to Semi-standard on page 56 for details.

Note) For CE compliant


models, DC-type only.

Metal seal
Rubber seal

Caution
Use the standard (DC)
specification when continuously
energizing for long periods of
time.

Enclosure
IP65 (Dust-tight,
Water-jet-proof)
Manual override

High-pressure type (0.95 W)

K Note 2) (1.0 MPa)

Nil

B
C
D

Negative

Note 1) For power consumption of


AC type, refer to page 16.
Note 2) Metal seal only
Note 3) For external pilot and negative common specifications,
refer to Semi-standard on
pages 56 to 57.
Note 4) When two or more symbols
are specified, indicate them
alphabetically. Combination
of [B] and [K] is not possible.

ta

External
pilot

R Note 3)

Write sequentially from the 1st


station on the D-side.
When part nos. written collectively are complicated,
specify them by means of the
manifold specification sheet.

Prefix the asterisk to


the part nos. of the
solenoid valve, etc.

tio

N Note 3) common

Non-locking push type (Tool required)


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

1 setManifold base part no.


3 setsValve part no. (Stations 1 to 3)
3 setsValve part no. (Stations 4 to 6)
2 setsValve part no. (Stations 7 to 8)
1 setBlanking plate part no. (Station 9)

High-speed (0.95 W)
response type

Note 1)

VV5Q21-09C6M2-W
VQ2100-51
VQ2200-51
VQ2300-51
VVQ2000-10A-1

Light/surge voltage
suppressor
Nil

Yes
None

Coil voltage
1
3
5
6

Note) For CE compliant


models, DC-type only.

0
1

Standard

CE compliant

sid

Seal

(0.4 W)

Nil

AC

2-position single
1
2-position double
2
3-position closed center
3
3-position exhaust center
4
3-position pressure center
5
A 4-position dual port (N.C. +N.C.)
B 4-position dual port (N.O. +N.O.)
C 4-position dual port (N.C. +N.O.)

DC

sid

Nil

Function
Symbol Specifications

<Example>
Circular connector kit with cable (3 m)

CE compliant

VQ2000

Type of actuation

Specify the part numbers for valves and options


together beneath the manifold base part number.

W1

Series
2

How to Order Manifold Assembly

ns

Negative
COM spec.

VQ 2 1 0 0

[Option]

None
None
None
None
None
None
None
White
Black
Black
Red
Red
Red
Black
Black
White
None
None
Black
White
White
Red
Red
White
None
None

How to Order Valves

Dot marking

Black
Brown
Red
Orange
Yellow
Pink
Blue
Purple
Gray
White
White
Yellow
Orange
Yellow
Pink
Blue
Purple
Gray
Orange
Red
Brown
Pink
Gray
Black
White
White

100 VAC (50/60 Hz)


110 VAC (50/60 Hz)
24 VDC
12 VDC

CE compliant

3m

52

G kit
T kit

SOL.A

Lead wire color

(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
(+)
Note) ()
()

L kit

SOL.B

Polarity

()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
(+)
(+)

S kit

Station 1

M kit

Terminal no.
SOL.A

Sub-plate
Single Unit

015
AXT100-MC26- 030 Wire color
050

Semistandard

Circular connector cable assembly

Construction

Wiring Specifications

Exploded
View of
Manifold

 Electrical

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

sid
e

S
ta
tio
ns

J kit

sid
e

P kit

F kit

Base Mounted Plug-in Unit

VQ-A.qxd

09.2.26 2:36 PM

Page 54

Series VQ2000
kit (Circular connector)

VV5Q21

< >: AC
The dashed lines and dimensions in parentheses indicate DIN rail mounting [-D].

(L4)
(L3)
L2
L1

Made by CONINVERS GmbH


HC-26P1NRAWF00

(5.25)

34.5
1

59
73.5 <77.5>
29.5

Indicator light
Manual
override

6.5

4 x M5
mounting hole

(12)

(35)

10.6
4

46.2

22

120 <126.9>
80

(5.5)

0.9

13
73.7

D side

Stations

U side

C10 [3(R) EXH port]


C10: 10 one-touch fitting
C10 [1(P) SUP port]
C10: 10 one-touch fitting

EXH

EXH

49
31.6
24.5
16

C4, C6, C8 [4(A), 2(B) port]


C4: 4 one-touch fitting
C6: 6 one-touch fitting
C8: 8 one-touch fitting
P = 16

47
65

Dimensions
n

L1
L2
(L3)
(L4)

53

(7.5)

9.5

(12)

DIN rail clamp screw

Formula L1 = 16n + 77.5, L2 = 16n + 100.5

n: Station (Maximum 12 stations)

10

11

12

109.5

125.5

141.5

157.5

173.5

189.5

205.5

221.5

237.5

253.5

269.5

132.5

148.5

164.5

180.5

196.5

212.5

228.5

244.5

260.5

276.5

292.5

162.5

175

187.5

200

225

237.5

250

275

287.5

300

312.5

173

185.5

198

210.5

235.5

248

260.5

285.5

298

310.5

323

Sub-plate Single Unit


VQ2000 Only

VQ2 1 0 0

+ Sub-plate

5 W 1

J kit

Valve

02
CE compliant
Nil

Entry is the same as


standard products.

T kit

Note) For CE compliant


models, DC-type only.

Enclosure
Nil

CE compliant

Thread type

Dust-protected

W Note 1) IP65 (Dust-tight, Water-jet-proof)

Nil

Rc

Note 1) Valves are IP65 specifications.


Note 2) When the valve is a standard (dustprotected) specification, it is not
compatible with 200 or 220 VAC.

NPT

NPTF

Port size
02

1/4

S kit

In the case of Sub-plate alone

L kit

Easy-to-use terminal block

VQ2000 PW 02

M kit

Terminal
block

G kit

In the case of

P kit

Note) For CE compliant


models, DC-type
only.
[Option]

How to Order

IP65 enclosure in
standard specifications

F kit

Series VQ2000

Dimensions
4

Sub-plate
Single Unit

89.4
(43.8)

2 x 4.5
(Mounting hole)

10.5
(A port)

Manual override

10.5
(B port)

Semistandard
Construction

VQ210 01 -1-02

45

37

Indicator light

121 <127.9>

Exploded
View of
Manifold

22.4
15.5

77.2

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Clamp screw

70.7

72.7 <76.7>

M5 x 0.8
External pilot port

R1

R2 3

25

12

15.4

25

2.5
G 3/8
Electrical entry

14.5

19.5

39.1
53.6

12

20
(A, B port)
25

43.8

5 x 1/4"
1(P), 4(A), 2(B), 5(R1), 3(R2) port

< >: AC
Note) When using this valve for IP65, mount a seal connector to the electrical entry.

54

VQ-A.qxd

09.2.26 2:36 PM

Page 56

Series VQ1000/2000
Semi-standard

Different Number of Connector Pins


F and P kits with the following number of pins are available besides the standard number (F = 25P; P = 26P). Select the desired number
of pins and cable length from the cable assembly list. Place an order for the cable assembly separately.

kit (D-sub connector)


15 pins

kit (Flat ribbon cable)


10/16/20 pins

How to Order Manifold

How to Order Manifold

VV5Q11

VV5Q11

06 C6 F SA

06 C6 P SC

Option

Option

Stations

Stations

Cylinder port

Cylinder port

How to Order

How to Order

D-sub connector, 15 pins


Connector locationSide
Without cable

Flat ribbon cable, 20 pins


Connector locationSide
Without cable

Location

Pins

15P (Max. 7 stations)

Kit type/Electrical entry

Top entry

F kit

Side entry

UA

F kit

SA

In the same way as the 25-pin models (standard), the terminal no. 1 is for
SOL.A at the 1st station, the terminal no. 9 for SOL.B at the 1st station, and
the terminal no. 8 for COM.
Multi-core vinyl cable
Wire Color Table by Terminal No. of
VVRF 0.3 mm2 x 15
D-sub Connector Cable Assembly
9 cores

Plug connector
HDA-CTH
(Made by Hirose Electric)

Connector
HAD-15S
(Made by Hirose Electric)
2 x M2.6 X 0.45

Terminal no.

Terminal no. Lead wire color Dot marking


1
Black
None
2
Brown
None
3
Red
None
4
Orange
None
5
Yellow
None
6
Pink
None
7
Blue
None
8
Purple
White
9
Gray
Black
10
White
Black
11
White
Red
12
Yellow
Red
13
Orange
Red
14
Yellow
Black
15
Pink
Black

D-sub Connector Cable Assembly


Cable length (L)

Pins

15P

10P (Max. 4 stations)


16P (Max. 7 stations)

Top entry

P
kit

20P (Max. 9 stations)

Side entry

UA
UB
UC

P
kit

SA
SB
SC

In the same way as the 26-pin models (standard), the terminal no. 1 is for
SOL.A at the 1st station, the terminal no. 2 for SOL.B at the 1st station, and
two pins from the max. terminal numbers are for COM.
Red

Flat Ribbon Cable Assembly


Pins

10P

16P

20P

1.5 m

AXT100-FC10-1

AXT100-FC16-1

AXT100-FC20-1

Cable length (L)

1.5 m

AXT100-DS15-1

3m

AXT100-FC10-2

AXT100-FC16-2

AXT100-FC20-2

3m

AXT100-DS15-2

5m

AXT100-FC10-3

AXT100-FC16-3

AXT100-FC20-3

5m

AXT100-DS15-3

17.2

24.8

30

For other commercial connectors, use a type conforming to MIL-C-24308.

55

Location

Pins

Terminal no.

Kit type/Electrical entry

Connector width (W)

For other commercial connectors, use a type with strain relief conforming
to MIL-C-83503.

Page 3

Series VQ1000/2000

F kit

Base Mounted Plug-in Unit

Special Wiring Specifications

Negative Common Specifications

In the internal wiring of F/P/J/G/T/S kit, double wiring (connected


to SOL. A and SOL. B) is adopted for each station regardless of
the valve and option types. Mixed single and double wiring is
available as an option.

Specify the valve model no. as shown below for negative


common specification.
The manifold no. shown below is for the T (VQ1000) and L
(VQ1000/2000) kits. For other kits the standard manifold can be
used. However, negative common is not compatible with S
(except EX510 gateway-type, EX240 integrated-type and EX120/
121/122 integrated-type (CompoNet)) and G kits.

1. How to Order
Indicate an option symbol -K, for the manifold no. and be
sure to specify the mounting position and number of stations
of the single and double wiring by means of the manifold
specification sheet.

How to Order Valves

VQ1100 N

VV5Q11 08C6FU1 D K S

51

G kit

Example)

P kit

10.11.29 11:32 AM

J kit

311-VQ-CT.qxd

Others, option symbols:


to be indicated alphabetically.

How to Order Manifold

2. Wiring specifications

T kit (VQ1000):

17
18

21

6
9

1st
row

Cylinder port

Sub-plate
Single Unit

J/G kit

2nd
row

Negative common
specifications

10

3rd
row

19
20

M kit

T kit
T kit
Terminal block Terminal block
(VQ1000, 24 terminals)
(VQ2000)

Stations
L kit (VQ1000/2000):

Type
Max.
points

F kit (D-sub
connector)

F US F US A P US P US C P US B P US A
25P 15P 26P 20P 16P 10P
24

VQ1000
VQ2000

Max.
points

14

24

18

14

T kit
(Terminal block box)

Kit

Type

P kit
(Flat ribbon cable)

2 rows of
3 rows of
terminal blocks terminal blocks

16

J kit (Flat
G kit (Flat ribbon cable
ribbon cable) with terminal block)

J US
20P

16

16

M kit
S kit
(Serial transmission) (Circular connector)

16

24

Semistandard

06 C6 L N 1

Stations

Construction

Kit

VV5Q11

Cylinder port
Negative common
specifications

Exploded
View of
Manifold

The maximum number of stations depends upon the number


of solenoids. Assuming one for a single and two for a double,
determine the number of stations so that the total number is
not more than the max. number given in the following table.

Electrical entry
Cable length
0
1
2

With cable (0.6 m)

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

3. Max. number of stations

With cable (1.5 m)


With cable (3 m)

24
20

M kit

26

22
11

L kit

25

23

12

Option

16

24

06 C6 T N

COM.

15
14
13

VV5Q11

S kit

With the A side solenoid of the 1st station as no.1 (meaning,


to be connected to no.1 terminal), without making any
terminals vacant.

F kit
P kit
D-sub connector
Flat ribbon
(25P)
cable connector
(26P)

T kit

Negative common specifications

Option

56

VQ-A.qxd

09.2.26 2:36 PM

Page 58

Series VQ1000/2000
Semi-standard

External Pilot Specifications

DIN Rail Mounting

When the supply air pressure is lower than the required minimum
operating pressure (0.1 to 0.2 MPa) for the solenoid valve (or
when the valve is used for vacuum), specify an external pilot
model. Order a manifold or valve by suffixing the external pilot
specification, R. The X-port of the manifold base is equipped
with one-touch fittings for external pilot.
VQ1000: C4 (4 one-touch fitting)
VQ2000: C6 (6 one-touch fitting)

Each manifold can be mounted on a DIN rail. Order it by


indicating a DIN rail mounting option symbol, -D. In this case, a
DIN rail which is approx. 30 mm longer than the manifold with the
specified number of stations is attached.

 When DIN rail is unnecessary


(DIN rail mounting brackets only are attached.)
Indicate the option symbol, -D0, for the manifold part number.

Example)

How to Order Manifold

VV5Q11 08C6FU1 D0 S

VV5Q11 08C6FU1 R S

Others, option symbols:


to be indicated alphabetically.

External pilot specifications

 When using DIN rail longer than the manifold with

Others, option symbols:


to be indicated alphabetically.

specified number of stations


Clearly indicate the necessary number of stations next to the option
symbol -D for the manifold part number.

How to Order Valves

Example)

VQ1100 R

VV5Q11 08C6FU1 D 09 S

51

DIN rail for 9 stations

External pilot specifications

Note 1) When two or more functions are specified, indicate them alphabetically.
Note 2) Since the pilot EXH of this valve is released from the R1 passage, it is not
possible to vacuum from a part other than EXH pressure and SUP ports.

Others, option symbols:


to be indicated alphabetically.

The number of stations that may be displayed is longer than the manifold
number of stations.

Inch-size One-touch Fittings

 When changing to a DIN rail mounting.


Order brackets for mounting a DIN rail. (Refer to Manifold Optional
Parts on pages 67 and 73.)

The valve with inch-size one-touch fittings is shown below.

VV5Q11

06 N7 PS0

No. VVQ1000-57A (For VQ1000)


VVQ2000-57A (For VQ2000)
2 pcs. per one set.

Stations
Option
Kit type/Electrical entry

 When ordering DIN rail only


DIN rail no.: AXT100-DR-
As for , specify the number from the DIN rail table.
Refer to the dimensions of each kit for L dimension.

Cylinder port
Symbol

N1

N3

N7

N9

M5T

NM

Applicable tubing O.D. (Inch)

1/8"

5/32"

1/4"

5/16"

10-32UNF
(M5 thread)

Mixed

4(A), 2(B)
port

(Pitch)

VQ1000
VQ2000

Note) When inch-size fittings are selected for the cylinder port, inch-size fittings are
selected on 1(P), 3(R) port, too.

1(P), 3(R) port size


VQ1000 5/16" (N9)
VQ2000 3/8" (N11)

57

L Dimension

L = 12.5 x n + 10.5

No.

10

L dimension

23

35.5

48

60.5

73

85.5

98

110.5

123

135.5

No.

11

12

13

14

15

16

17

18

19

20

L dimension

148

160.5

173

185.5

198

210.5

223

235.5

248

260.5

No.

21

22

23

24

25

26

27

28

29

30

L dimension

273

285.5

298

310.5

323

335.5

348

360.5

373

385.5

No.

31

32

33

34

35

36

37

38

39

40

L dimension

398

410.5

423

435.5

448

460.5

473

485.5

498

510.5

Exploded
View of
Manifold
Construction

Semistandard

Sub-plate
Single Unit

M kit

S kit

L kit

T kit

G kit

J kit

P kit

F kit

09.2.26 2:36 PM

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

VQ-A.qxd
Page 59

58

VQ-A.qxd

09.2.26 2:36 PM

Page 60

Series VQ1000/2000

Construction
VQ1000 Plug-in Unit: Main Parts/Replacement Parts
Metal seal

Rubber seal
eqw

VQ1100

eqw

VQ1101

(A) (B)
4 2

r
5 1 3
(R1) (P)(R2)

5 1 3
(R1) (P)(R2)

eqw

eqw

VQ1200

VQ1201

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

r
eqw

VQ1300

(A) (B)
4 2

eq

VQ1500

VQ1301

VQ1400 (A) (B)

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

VQ1401 (A) (B)

4 2

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

VQ1501

5 1 3
(R1) (P)(R2)

4 2

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

eq

VQ1A01

VQ1B01

4
(A)
5
(R1)

2
(B)

1
(P)

VQ1C01
4
(A)

5
(R1)

Component Parts
No.
1
2
3
4

Description
Body
Spool/Sleeve
Piston
Pilot valve assembly

5
(R1)

2
(B)

1
(P)

3
(R2)

2
(B)

1
(P)

3
(R2)

Component Parts
Material
Zinc die-casted
Stainless steel
Resin

Note

Note) Refer to page 62 for How to Order Pilot Valve Assembly.

59

3
(R2)

4
(A)

No.
1
2
3
4

Description
Body
Spool valve
Piston
Pilot valve assembly

Material
Zinc die-casted
Aluminum, HNBR
Resin

Note

Note) Refer to page 62 for How to Order Pilot Valve Assembly.

VQ-A.qxd

09.2.26 2:36 PM

Page 61

Base Mounted Plug-in Unit

Series VQ1000/2000

Metal seal

F kit

VQ2000 Plug-in Unit: Main Parts/Replacement Parts


Rubber seal
q

VQ2101

(A) (B)
4 2

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

5 1 3
(R1) (P)(R2)

T kit

G kit

VQ2100

J kit

P kit

VQ2201

5 1 3
(R1) (P)(R2)

5 1 3
(R1) (P)(R2)

r
e

M kit

(A) (B)
4 2

L kit

(A) (B)
4 2

S kit

VQ2200

VQ2501

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

5 1 3
(R1) (P)(R2)

VQ2A01
4
(A)

5
(R1)

2
(B)

1
(P)

VQ2C01
4
(A)

5
(R1)

Component Parts
No.
1
2
3
4

Description
Body
Spool/Sleeve
Piston
Pilot valve assembly

5 1 3
(R1) (P)(R2)

5 1 3
(R1) (P)(R2)

(A) (B)
4 2

4 2

Sub-plate
Single Unit

5 1 3
(R1) (P)(R2)

VQ2401 (A) (B)

(A) (B)
4 2

Semistandard

VQ2500

4 2

Construction

5 1 3
(R1) (P)(R2)

VQ2301

VQ2400 (A) (B)

VQ2B01

3
(R2)

4
(A)

5
(R1)

Exploded
View of
Manifold

(A) (B)
4 2

2
(B)

1
(P)

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

VQ2300

3
(R2)

2
(B)

1
(P)

3
(R2)

Component Parts
Material
Zinc die-casted
Stainless steel
Resin

Note

Note) Refer to page 62 for How to Order Pilot Valve Assembly.

No.
1
2
3
4

Description
Body
Spool valve
Piston
Pilot valve assembly

Material
Zinc die-casted
Aluminum, HNBR
Resin

Note

Note) Refer to page 62 for How to Order Pilot Valve Assembly.

60

225-VQ-CT.qxd

10.10.7 5:14 PM

Page 1

Exploded View of Manifold


VQ1000 Plug-in Unit: Exploded View
(F/P/J/L/S kit)

Housing assembly, SI unit,


D-side end plate assembly

Manifold block assembly

U-side end plate assembly

S kit

P/J kit

!5
w

o
r

!0

!4

25 pins
(Top entry)
(Integral
housing type)

!1

F kit

!3

15 pins
(Upward side
entry)
25 pins
(Side entry)

!2

L kit

t
61

F kit

Exploded View of Manifold

P kit

<Housing Assembly and SI Unit>


Housing assembly and SI unit no.

<D-Side End Plate Assembly>

Nil

Option
Nil

R Note 1)
S Note 1)

R
S

Common EXH
External pilot
Direct EXH outlet with
built-in silencer

i Manifold block assembly no.

F0
F1
F2
F3
P1
P2
P3
L0
L1
L2

Without lead wire


F kit for 2 to 12 stations/Double wiring
F kit for 13 to 24 stations/Double wiring
F kit for 2 to 24 stations/Single wiring
P/J/S kit for 2 to 12 stations/Double wiring
P/J/S kit for 13 to 24 stations/Double wiring
P/J/S kit for 2 to 24 stations/Single wiring
L0 kit : Stations (1 to 8)
L1 kit : Stations (1 to 8)
L2 kit : Stations (1 to 8)

<Fitting Assembly>
!3 Fitting assembly part no. (For cylinder port)

Tie-rod (2 pcs.) and lead wire


assembly for extensions are
attached.

VVQ1000-50A-

C3
C4
C6
M5

With 3.2 one-touch fitting


With 4 one-touch fitting
With 6 one-touch fitting
M5 thread
Without one-touch fitting
C0 (With clip)

Part no.

VVQ1000-80A-1
VVQ1000-80A-2
VVQ1000-80A-3
VVQ1000-80A-4

Description
Gasket
Packing
Clamp screw
Clip

Port size

Note) Purchasing order is available


in units of 10 pieces.

C3
C4
C6
M5

Applicable tubing 3.2


Applicable tubing 4
Applicable tubing 6
M5 thread

!44 Fitting assembly part no. (For 1(P), 3(R) port)

VVQ1000-51A-C8
Applicable tubing 8
Note) Purchasing order is available
in units of 10 pieces.

!5 Tie-rod assembly part no. (2 pcs./set)

VVQ1000-TR-

Replacement Parts
o
!0
!1
!2

J kit

VVQ1000-2A-1-L

<Replacement Parts for Manifold Block>


No.

G kit

u U-side end plate assembly no. (For L kit)

Port size

Electrical entry

T kit

Note) The !4s fitting assembly is


included.

Note 1) When both options are specified, indicate as RS.


Note 2) The housing assembly and SI unit of F/P/J/S kit
are not included (except FU25). Separately place
an order for q, w, e.

<Manifold Block Assembly>

Common EXH
External pilot
Direct EXH outlet with built-in silencer

M kit

For F kit top entry 25 pins


For F kit other than above
For J/P kit
For L kit
For S kit

VVQ1000-1A-

Option

Sub-plate
Single Unit

Electrical entry
FU25
F
P
L
S

VVQ1000-2A-1-

L kit

y U-side end plate assembly no. (For F/P/J/S kit)

rt D-side end plate assembly no.

VVQ1000-3A-1-

<U-Side End Plate Assembly>

S kit

Note 1) Top entry connector for PU, JU while side entry connector for PS, JS.
Note 2) Suffix -XP to the end of the part number for dust-protected SI unit. (Not available for S/SQ kit)

Semistandard

Description
NKE Corp.: Uni-wire System (16 outputs)
NKE Corp.: Uni-wire H System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Flat ribbon cable housing assembly = Number of pins: 26/20/16/10
Flat ribbon cable housing assembly
D-sub connector housing assembly (Top entry) Number of pins: 15
D-sub connector housing assembly (Side entry) = Number of pins: 25/15

Construction

Part no.
EX120-SUW1(-XP) Note 2)
EX120-SUH1(-XP) Note 2)
EX120-SSL1(-XP) Note 2)
EX120-SSL2(-XP) Note 2)
EX120-SDN1
EX120-SCS1(-XP) Note 2)
EX120-SCS2(-XP) Note 2)
EX120-SMJ1(-XP) Note 2)
AXT100-1-P US Note 1)
AXT100-1-J US 20 Note 1)
AXT100-1-FU15
AXT100-1-FS

Exploded
View of
Manifold

Manifold
(SF1 kit)
(SH kit)
(SJ1 kit)
(SJ2 kit)
(SQ kit)
(SR1 kit)
(SR2 kit)
(SV kit)
PUS kit
J US kit
FU kit
FS kit

Note 1) Please order when eliminating manifold stations.


When adding stations, tie-rods are attached to the manifold block
assembly. Therefore, it is not necessary to order.
Note 2) : Stations 02 to 24
Note 3) For S/P/J/F/L kit

Material
Quantity
HNBR
12
HNBR
12
Carbon steel
12
Stainless steel
12

Pilot valve assembly

V112

Note) A set of parts containing 12 pcs. each is enclosed.

Coil voltage

Function
Symbol Specifications
Nil

B
K

Standard

DC
(0.4 W)

High-speed (0.95 W)
response type
High-pressure type (0.95 W)

(1.0 MPa)

AC
Note 1)

1
2
3
4
5
6

100 VAC (50/60 Hz)


200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

Enclosure
Dust-tight,

A Water-jet-proof
(IP65)

B Dust-protected

Note 1) Refer to page 16 for power consumption of AC type.


Note 2) Common to single solenoid and double solenoid

62

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

No.

VQ-A.qxd

09.2.26 2:36 PM

Page 64

Exploded View of Manifold


VQ2000 Plug-in Unit: Exploded View
(F/P/J/L/G/S kit)
D-side end plate
assembly

Manifold block assembly

U-side end plate assembly

S kit

Housing assembly
and SI unit

q
!3

P/J kit

!0
u

!5

F kit

!2

!1

!6

!4

G kit

L kit

y
63

Exploded View of Manifold

F kit

<Housing Assembly and SI Unit>


Housing assembly and SI unit no.

P kit
J kit
G kit

e
r

Note 1) Suffix -XP to the end of the part number for dust-protected SI unit.
Note 2) Dust-tight, Water-jet-proof (IP65)
Note 3) Top entry connector for FU, PU, JU while side entry connector for FS, PS, JS.

<D-Side End Plate Assembly>

<U-Side End Plate Assembly>

ty D-side end plate assembly no.

u U-side end plate assembly no. (For F/P/J/G/T/S/M kit)

VVQ2000-3A-1-

VVQ2000-2A-1R

Note) F/P/J/G kit are available with Nil only.


M kit is available with [W] only.
S/L/T kit are selectable depending on the
manifold type.

Option
Nil

R Note 1)
S Note 1)

Nil

Note) F/P/J/G kit are available with Nil only.


M kit is available with [W] only.
S/T kit are selectable depending on the
manifold type.

i U-side end plate assembly no. (For L kit)

VVQ2000-2A-1-LEnclosure
Nil

<Manifold Block Assembly>


o Manifold block assembly no.

VVQ2000-1A-

Tie-rod (2 pcs.) and lead wire assembly


for extensions are attached.

Electrical entry
F0
F1
F2
F3
P1
P2
P3
L0
L1
L2
T1
T3
M1
M2
M3

C4
C6
C8
C0

Dust-protected
Dust-tight, Water-jet-proof (IP65)

Note) Select it depending on the manifold type.

Port size

Without lead wire


F kit for 2 to 12 stations/Double wiring
F kit for 13 to 24 stations/Double wiring
F kit for 2 to 24 stations/Single wiring
P/J/G/S kit for 2 to 12 stations/Double wiring
P/J/G/S kit for 13 to 24 stations/Double wiring
P/J/G/S kit for 2 to 24 stations/Single wiring
L0 kit : Stations (1 to 8)
L1 kit : Stations (1 to 8)
L2 kit : Stations (1 to 8)
T kit for 2 to 20 stations/Double wiring
T kit for 2 to 20 stations/Single wiring
M kit for 2 to 12 stations/Double wiring
M kit for 13 to 24 stations/Double wiring
M kit for 2 to 24 stations/Single wiring

Dust-protected
Dust-tight, Water-jet-proof (IP65)

Note 1) The !5s fitting assembly is included.


Note 2) The housing assembly and SI unit of F/P/J/G/S kit are not included.
Separately place an order for q, w, e, r.
Note 3) S (Built-in silencer) and W (IP65) cannot be combined.

Common EXH
External pilot
Direct EXH outlet with built-in silencer

Note 1) When both options are specified, indicate as RS.


Note 2) The housing assembly and SI unit of F/P/J/G/S kit are not included.
Separately place an order for q, w, e, r.
Note 3) S (Built-in silencer) and W (IP65) cannot be combined.

Enclosure

Common EXH
External pilot
Direct EXH outlet
with built-in silencer

M kit

Nil

L kit

Dust-protected
Dust-tight, Water-jet-proof (IP65)

Enclosure

With 4 one-touch fitting


With 6 one-touch fitting
With 8 one-touch fitting
Without one-touch fitting (With clip)

Nil

Semistandard

Nil

For F kit
For G/J/P kit
For L kit
For S kit

Dust-protected
Dust-tight, Water-jet-proof (IP65)

Note) F/P/J/G kit are available with Nil only.


M kit is available with [W] only.
S/L/T kit are selectable depending on the manifold type.

<Fitting Assembly>
!44 Fitting assembly part no. (For cylinder port)

VVQ1000-51A-

Exploded
View of
Manifold

F
P
L
S

Option

Enclosure

Construction

Electrical entry

Port size

Note) Purchasing order is available


in units of 10 pieces.

C4 Applicable tubing 4
C6 Applicable tubing 6
C8 Applicable tubing 8

!55 Fitting assembly part no. (For 1(P), 3(R) port)

<Replacement Parts for Manifold Block>


Replacement Parts
No.

Part no.

!0
!1
!2
!3

VVQ2000-80A-1
VVQ2000-80A-2
VVQ2000-80A-3
VVQ2000-80A-4

Description
Gasket
Seal
Clamp screw
Clip

Material
Quantity
HNBR
12
HNBR
12
Carbon steel
12
Stainless steel
12

Note) A set of parts containing 12 pcs. each is enclosed.

VVQ2000-51A-C10
Applicable tubing 10
Note) Purchasing order is available
in units of 10 pieces.

!6 Tie-rod assembly part no. (2 pcs./set)

VVQ2000-TR-

T kit

Description
NKE Corp.: Uni-wire System (16 outputs)
NKE Corp.: Uni-wire H System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (16 outputs)
Panasonic Electric Works SUNX Co., Ltd.: S-LINK System (8 outputs)
DeviceNet
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Flat ribbon cable housing assembly : Number of pins: 26/20/16/10
Flat ribbon cable housing assembly
D-sub connector housing assembly : Number of pins: 25/15
Flat ribbon cable housing assembly with terminal block

S kit

Part no.
EX120-SUW1(-XP) Note 1) [EX123D-SUW1] Note 2)
EX120-SUH1(-XP) Note 1) [EX123D-SUH1] Note 2)
EX120-SSL1(-XP) Note 1) [EX123D-SSL1] Note 2)
EX120-SSL2(-XP) Note 1) [EX123D-SSL2] Note 2)
EX120-SDN1 [EX124D-SDN1] Note 2)
EX120-SCS1(-XP) Note 1) [EX124D-SCS1] Note 2)
EX120-SCS2(-XP) Note 1) [EX124D-SCS2] Note 2)
EX120-SMJ1(-XP) Note 1) [EX124D-SMJ1] Note 2)
AXT100-1-PUS Note 3)
AXT100-1-J US20 Note 3)
AXT100-1-F US Note 3)
AXT100-1-GU20

Sub-plate
Single Unit

Manifold

(SF1 kit)
(SH1 kit)
(SJ1 kit)
(SJ2 kit)
(SQ kit)
(SR1 kit)
(SR2 kit)
(SV kit)
P US kit
J US kit
FUS kit
G kit

Note 1) Please order when eliminating manifold


stations.
When adding stations, tie-rods are attached
to the manifold block assembly. Therefore, it
is not necessary to order.
Note 2) : Stations 02 to 24
Note 3) For S/P/J/F/L kit

64

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

No.

VQ-A.qxd

09.2.26 2:36 PM

Page 66

Series VQ1000
VQ1000: Manifold Optional Parts
Blanking plate assembly
VVQ1000-10A-1

JIS symbol

It is used by attaching on the manifold block for being


prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc.

Individual SUP spacer

Individual SUP spacer


VVQ1000-P-1- C6
N7

SUP block plate


Individual
SUP spacer

SUP block plate


Valve

Valve

U side

Block indication label


A label indicating the SUP
passage blocking position
is to be adhered.
ide
Us
SUP block plate

ide

Ds

C6 (EXH port)
C6: 6 one-touch fitting

Single

Individual EXH spacer


VVQ1000-R-1-C6

A label indicating the EXH


passage blocking position
is to be adhered.

EXH block
base assembly

EXH blocking position: Specify 2 places.

Block indication label

EXH
passage
blocked

Stations

Description/Model

Individual EXH spacer

Valve

Individual EXH spacer


VVQ1000-R-1- C6
N7
When valve exhaust affects other stations due to the
circuit configuration, this spacer is used for individual
valve exhaust. (One station space is occupied.)
Block both sides of the individual valve EXH station.
(Refer to the application example.)
Specify the mounting position, as well as the EXH
block base or EXH block plate position by means of
the manifold specification sheet. The block plate is
used in one or two places for one set.
An EXH block base assembly is used in the blocking
position when ordering an EXH spacer incorporated
with a manifold no. However, do not order an EXH
block base assembly because it is attached to the
spacer.
When separately ordering an individual EXH spacer,
separately order an EXH block base assembly because it is not attached to the spacer.
As a standard, electric wiring is connected to the position of the manifold station where the individual EXH
spacer is mounted.
If wiring is not required for stations equipped with
spacers, enter X in the special wiring specifications
column in the manifold specification sheet.

Valve

D side

Option

When the same manifold is to be used for different pressures, individual SUP spacers are used as SUP ports for
different pressures. (One station space is occupied.)
Block both sides of the station, for which the supply
pressure from the individual SUP spacer is used, with
SUP block plates. (Refer to the application example.)
Specify the spacer mounting position and SUP block plate
position by means of the manifold specification sheet.
The block plate is used in one or two places for one set.
(Two SUP block plates for blocking SUP station are
attached to the individual SUP spacer.)
As a standard, electric wiring is connected to the position of the
manifold station where the individual SUP spacer is mounted.
If wiring is not required for stations equipped with
spacers, enter X in the special wiring specifications
column in the manifold specification sheet.

C6 (SUP port)
C6: 6 one-touch fitting

Individual EXH spacer


+
EXH block base assembly

D side

Valve

Valve
+
EXH block base assembly

(Not to be
ordered)

Valve

(Not to be
ordered)

U side

SUP block plate


VVQ1000-16A
Block indication
label

When different pressures are supplied to a manifold, a


SUP block plate is used to block the stations under different pressures.

ide
Us

Specify the mounting position by means of the manifold specification sheet.


ide
Ds

Nil
1
2

Connector
Without connector
With connector/2-wire
With connector/4-wire

JIS symbol

Connector lead wire length (mm)


Nil
300
20 2000
6
600
25 2500
10 1000
30 3000
15 1500

Blanking plate with a connector for individually outputting electricity to


drive a single valve or equipment that are not on the manifold base.
When N is suffixed to the end of the name plate, the plate will be different from a standard shape.
Note) Electric current should be 1A or less (including the mounted valves).

65

SUP passage blocked

SUP/EXH passage blocked

Connector on the power


supply side is not attached.
Blanking
plate with
connector

Connector
assembly

Connector assembly part no.


AXT661- 43 A- 6

Lead wire
length (mm)

AC

Lead wire color: Black


Lead wire color: Red
Lead wire color: White

43 4-wire
44 2-wire

24AWG
Cover O.D. 1.5
Power
supply side

Blanking plate with connector


VVQ1000-1C -

Blanking
plate side

Indication labels to confirm the blocking position are attached (Each for SUP passage and SUP/EXH passage
blocking positions).
When ordering a block plate incorporated with a
manifold, a block indication label is attached to the
manifold.

<Block indication label>

Nil
6
10
20
30

300
600
1000
2000
3000

09.2.26 2:36 PM

Page 67

Base Mounted Plug-in Unit

EXH block base assembly


F
VVQ1000-19A- PL -(C3/C4/C6/M5/N1/N3/N7)

Black screw

Manifold block assembly


Electrical entry

U side

Block indication label

ide
Us

EXH
passage blocked

P kit

Without lead wire


For F kit (2 to 12 stations)/Double wiring
For F kit (13 to 24 stations)/Double wiring
For F kit (2 to 24 stations)/Single wiring
For P, G, T, S kit (2 to 12 stations)/Double wiring
For P, G, T, S kit (13 to 24 stations)/Double wiring
For P, G, T, S kit (2 to 24 stations)/Single wiring
L0 kit
L1 kit 1 to 8 stations
L2 kit

The manifold block assembly is used between stations for


which exhaust is desired to be divided when valve exhaust
affects other stations due to the circuit configuration. The
EXH passage on the D-side is blocked in the EXH block
base assembly. It is also used in combination with an individual EXH spacer for individual exhaust.

EXH block
base assembly

D side

ide
Ds

J kit

Solid forming

Specify the mounting station by means of the manifold


specification sheet.
When ordering this option incorporated with a manifold,
specify the EXH block base assembly part number with
in front of it beneath the manifold part number.

G kit

F0
F1
F2
F3
P1
P2
P3
L0
L1
L2

Series VQ1000

F kit

VQ-A.qxd

SUP/EXH passage blocked

L kit

2 pcs. in 1 set

Back pressure check valve assembly [-B]


VVQ1000-18A

(Precautions)
1. The back pressure check valve assembly is the parts with a check
valve structure. However, since the
valve has slight air leakage, take
precautions for the exhaust air not
to be restricted at the exhaust port.
2. When a back pressure check valve
is mounted, the effective area of
the valve will decrease by about
20%.
9

It prevents cylinder malfunction caused by other valve exhaust


entry. Insert it into R (EXH) port on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is
used or an exhaust center type solenoid valve is used.
When ordering it being mounted on all manifold stations, suffix -B to the end of the manifold part number.
Note) When a back pressure check valve is desired, and is to
be installed only in certain manifold stations, clearly indicate the part number and specify the mounting station
by means of the manifold specification sheet.
7
6
5
4
3
2
1

KQ2P-
It is inserted into an unused cylinder port
and SUP/EXH ports.
Purchasing order is available in units of 10
pieces.

n: Stations

Semistandard

Note) ( ): VVQ1000-NC-n

Dimensions
Applicable
fitting size
d
3.2
4
6
8

Model

KQ2P-23
KQ2P-04
KQ2P-06
KQ2P-08

16
16
18
20.5

31.5 3.2
32
6
35
8
39 10

Applicable
fitting size
d
1/8"
5/32"
1/4"
5/16"

Model

KQ2P-01
KQ2P-03
KQ2P-07
KQ2P-09

16
16
18
20.5

31.5 5
32
6
35 8.5
39 10

The plug is used to block the cylinder port.


When ordering this option incorporated with a manifold, indicate CM for the port
size of the manifold part number, as well as, the mounting station and cylinder port
mounting positions 4(A) and 2(B) by means of the manifold specification sheet.
Gently screw an M3 screw in the port plug hole and pull it for removal.

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Port plug
VVQ0000-58A

Hole

40

13.5

Elbow fitting assembly


VVQ1000-F-L(C3/C4/C6/M5/N1/N3/N7)
It is used for piping that extends upward or downward from the
manifold.
When ordering this option incorporated with a manifold, indicate
L or B for the manifold port size (when installed in all stations.)
When installing it in part of the manifold stations, specify the elbow
fitting assembly part number and the mounting station by means of
the manifold specification sheet.
When mounting elbow fitting assembly on the edge of manifold
station and a silencer on EXH port, select a silencer, AN203-KM8.
A silencer (AN200-KM8) is interfered with fittings.

Downward

Construction

Blanking plug (For one-touch fittings)

Sub-plate
Single Unit

P = 10.5

N: Standard
NC: For mounting
blanking plate
with connector

Exploded
View of
Manifold

It is a transparent resin plate for placing a label that indicates solenoid valve function, etc.
Insert it into the groove on the side of the end plate
and bend it as shown in the figure.
When the blanking plate with connector is mounted, it
automatically will be VVQ1000-NC-n
When ordering this option incorporated with a manifold, suffix -N to the end of the manifold part number.

Name plate [-N]


VVQ1000- N
NC -N-Station (1 to Max. stations)

S kit

EXH passage blocked

M kit

Indication labels to confirm the blocking position are attached. (Each for EXH passage and SUP/EXH passage
blocking positions)
When ordering a EXH block base incorporated with a manifold, a block indication label is attached to the manifold.

T kit

<Block indication label>

Upward

66

VQ-A.qxd

09.2.26 2:36 PM

Page 68

Series VQ1000
VQ1000: Manifold Optional Parts
DIN rail mounting bracket [-D/-D0/-D]
VVQ1000-57A
It is used for mounting a manifold on a DIN rail.
When ordering this option incorporated with a manifold, suffix D to the end of the manifold part number.
1 set of DIN rail mounting bracket is used for 1 manifold
(2 DIN rail mounting brackets).

DIN rail clamp screw

Direct EXH outlet with built-in silencer [-S]

Mounting screws are attached.

Exhaust

This is a type with an exhaust port a top the manifold


end plate. The built-in silencer exhibits an excellent
noise suppression effect. (Noise reduction: 30 dB)
When ordering this option incorporated with a manifold, suffix S to the end of the manifold part number.
Note) A large quantity of drainage generated in
the air source results in exhaust of air
together with drainage.
 Refer to back page 5 for maintenance.

Dual flow fitting assembly


VVQ1000-52A- C8
N9

This is a fitting to multiply the flow rate by combining the outputs of 2


valve stations. It is used for driving a large bore cylinder. This is a onetouch fitting for a port size of 8 or 5/16.
The port size for the manifold part number is CM.
Clearly indicate the dual flow fitting assembly part number and specify
the mounting station by means of the manifold specifications.
In dual flow fitting assembly, a special clip which is combined in onepiece of 2 stations is attached as a holding clip.

Silencer (For EXH port)

Dimensions

Series

Applicable
fitting size
d

VQ1000

How to Order

Regulator unit
VVQ1000-AR-1
The regulator controls the SUP pressure in a manifold.
Supply air from D-side SUP port is regulated. SUP port
on U-side is plugged.
When a regulator unit is mounted, the SUP port on the
U-side of the manifold will be plugged. A maximum of 3
units can be mounted on a manifold.

Specifications
0.8
Maximum operating pressure (MPa)
0.05 to 0.7
Set pressure range (MPa)
5 to 50
Ambient and fluid temp. (C)
Air
Fluid
0.02
Cracking pressure valve (MPa)
Relieving type
Structure
Pressure gauge
G27-10-01

Indicate an option symbol -G* for the manifold no. and


be sure to specify the mounting position and number of
stations by means of the manifold specification sheet.
One unit is counted as one station and occupies a space
for three stations, therefore, pay attention to the manifold
size. The regulator valve unit, to which no wire is connected, valves can be mounted up to the standard max. number of stations of each kit.

How to Order Manifold


VV5Q11-14C6FUO-D G 2
Number of
manifold stations
Number of mounted
valves 12 sets
+
Number of regulator
units 2 sets

AN200-KM8

59

78

22

20

AN203-KM8

32

51

16

14

(mm2)

Number of
regulator units 2 sets

(dB)
30
25

Conditions:
Inlet pressure 0.7 MPa

Flow rate (Nl/min)

Pressure
Characteristics

Inlet pressure 0.7 MPa


Conditions (Initial setting) Outlet pressure 0.2 MPa

With regulator unit

Outlet pressure MPa

Flow Characteristics

Others, option symbols:


to be indicated alphabetically.

Pressure
control screw

Effective Noise
area reduction

Model

Outlet pressure MPa

This silencer is to be inserted into the EXH port (onetouch fittings) of the common exhaust type.
When mounting elbow fitting assembly (VVQ1000-FL) on the edge of manifold station, select a silencer,
AN203-KM8. A silencer (AN200-KM8) is interfered with
fittings.

31.5

Initial setting
value

+
SMC

102

SUP port on
U-side is plugged.

VVQ1000-AR-1

C8 (SUP) port
8 one-touch fitting
D side

Regulator unit

Valve

Inlet pressure (MPa)

Caution

U side

SMC

78
63.5

Pressure setting
Check the inlet pressure and then turn the pressure control screw to
set the outlet pressure. Turning the screw clockwise will increase the
outlet pressure while turning it counterclockwise decrease the pressure. (Set the pressure by turning the screw in the increase direction.)

Counted as
one station.

67

Installation
Since some level of the actuators operational frequency may lead to a
sharp pressure change, pay attention to the pressure gauge durability.

Page 69

Double check block (Separated) for VQ1000


VQ1000-FPG--

F kit

Series VQ1000

Base Mounted Plug-in Unit

<Circuit diagram>

It is used on the outlet side piping to keep the cylinder in


the intermediate position for a long time. Combining the
double check block with a built-in pilot type double check
valve and a 3-position exhaust center solenoid valve will
enable the cylinder to stop in the middle or maintain its
position for long periods of time.
The combination with a 2-position single/double solenoid
valve will permit this block to be used for preventing the
dropping at the cylinder stroke end when the SUP
residual pressure is released.

Cylinder side pressure


(P2)

J kit

P kit

09.2.26 2:36 PM

Specifications
Max. operating pressure
Min. operating pressure
Ambient and fluid temp.
Flow characteristics: C
Max. operating frequency

0.8 MPa
0.15 MPa
5 to 50C
0.60 dm3/(sbar)
180 c.p.m

SUP side pressure (P1)


To
CY
Lp
ort

Note) Based on JIS B 8375-1981


(Supply pressure: 0.5 MPa)

VVQ1000-FPG-02 1 set
VQ1000-FPG-C6M5-D 2 pcs.

G kit

VQ-A.qxd

Single unit

T kit

Dimensions
Manifold

L kit

2n x C4, C6
C4: 4 one-touch fitting
C6: 6 one-touch fitting

2 x C4, C6
C4: 4 one-touch fitting
C6: 6 one-touch fitting

Residual pressure release


manual override

Dimensions
n

L1
L2
L3
n

L1
L2
L3

How to Order

Formula L1 = 11n + 20

n: Station (Maximum 24)

31

42

53

64

75

86

97

108

119

50

62.5 75

112.5 125

125

137.5 150

87.5 100

60.5 73

85.5 98

13

15

163

14
174

185

187.5 187.5 200


198

198

16
196

110.5 123

17
207

212.5 225

210.5 223

18
218

135.5 135.5 148

19

20

21

10
130

22

240

251

237.5 250

250

262.5 275

260.5 260.5 273

262

12
152
185.5

23
273

24
284

287.5 300

285.5 298

310.5

Double check block

<Example>

C4 M5

IN side port size


M5
C3
C4
C6
N3
N7

OUT side port size


M5
C3
C4
C6
N3
N7

M5 thread
3.2 one-touch fitting
4 one-touch fitting
6 one-touch fitting
5/32" one-touch fitting
1/4" one-touch fitting

M5 thread
3.2 one-touch fitting
4 one-touch fitting
6 one-touch fitting
5/32" one-touch fitting
1/4" one-touch fitting

Manifold (DIN rail mounting)

VVQ1000 FPG

2-position

06
Stations

Option
Nil

F
D
N

3-position
exhaust center

Exploded
View of
Manifold

VQ1000 FPG

U side

2n x C3, C4, C6, M5


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

162.5 175

160.5 173

229

235.5 248

11
141

DIN rail clamp screw

Stations 1 2 3

Semistandard

D side

Construction

2 x C3, C4, C6, M5


C3: 3.2 one-touch fitting
C4: 4 one-touch fitting
C6: 6 one-touch fitting
M5: M5 thread

None
With bracket
DIN rail mounting
(For manifold)
Name plate

Note) When two or more symbols are specified, indicate them alphabetically.
Example) -DN

Drop
prevention

Intermediate
stops

Caution

Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from
stopping for long periods of time. Check the leakage using neutral household detergent, such as dish
1 station
01
washing soap. Also check the cylinders tube gasket, piston packing and rod packing for air leakage.
Since one-touch fittings allow slight air leakage, screw piping (with M5 thread) is recommended when
stopping the cylinder in the middle for long periods of time.
<Ordering example>
16 16 stations
Combining double check block with 3-position closed center or pressure center solenoid valve will not work.
VVQ1000-FPG-06...6-station manifold
M5 fitting assembly is attached, not incorporated into the double check block. After screwing in the M5
VQ1000-FPGBracket Assembly
fittings, mount the assembly on the double check block. {Tightening torque: 0.8 to 1.2 Nm}
C4M5-D, 3 sets Double
Part no.
Tightening torque If the exhaust of the double check block is restricted too much, the cylinder may not operate properly and
check block
VQ1000-FPGmay not stop intermediately.
VQ1000-FPG-FB 0.22 to 0.25 Nm Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
C6M5-D, 3 sets

When ordering a double check block,


order the DIN rail mounting [-D].

68

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Residual pressure
release manual
override

Sub-plate
Single Unit

M kit

M2.5 mounting
hole

S kit

M3 mounting hole

VQ-A.qxd

09.2.26 2:36 PM

Page 70

Series VQ1000
VQ1000: Manifold Option/With Ejector Unit
An ejector unit can be mounted on the manifold base for a solenoid valve.
Instead of mounting the valve and ejector unit separately, this option
reduces piping, wiring and creates additional space savings.

SET

U side
4
1
2
3
4
3
2
3

2
1

D side

Note 1) SUP and EXH ports on


the ejector unit manifold
base are arranged on Dside alone. The end plate
on the U-side is the same
as that used in the L kit.
Note 2) Individual piping is
provided for the supply
and exhaust ports of the
ejector unit.
Note 3) The manifold with an
ejector unit is mounted
from the U-side.
Note 4) One vacuum ejector unit
corresponds to one
station.
Specify the mounting station by
means of the manifold specification sheet.

Specifications
VVQ1000-J-1-A VVQ1000-J-1-B

Ejector valve model


Nozzle diameter (mm)

0.7

Max. suction flow rate N (Nl/min)

11

1.0
20

Max. vacuum pressure (mmHg)

630

Max. operating pressure (MPa)

0.7 (High-pressure type 0.8)

Standard supply pressure (MPa)

0.5

Operating temperature (C)

5 to 50

Maximum Number of Ejector Units


(Max. number of ejector units is subject to the number of valve stations.)
Max. number of mounted valves

Max. number of
ejector units

F, P, T kit

S, G, J kit

L kit

11 (20)

7 (14)

10 (16)

6 (12)

9 (12)

5 (10)

8 (8)

4 (8)

4 (4)

3 (4)

Note) The max. number of mounted valves applies to double wiring.


Parenthesized numbers apply to single wiring. Please contact SMC for
conditions other than the above or mixed wiring.

Dimensions

Manual override for


supply valve

A
B

Manual override for


release valve
94
86

Vacuum pressure switch


Ejector valve

Indicator light

Restrictor
(Release flow
adjustment)

Air supply
valve

SET

63

HYS

Vacuum
release valve

Ejector SUP port


(C6)

37.2

Ejector EXH port


(C8)
Vacuum port
(C6)

How to Order

VV5Q11 05C6FUO J P 1 S
Vacuum switch
Nil

None
With

Number of ejectors
1 to 5

Others, option symbols:


to be indicated alphabetically.

69

Example)
VV5Q11-05C6FUO-JP1 ...... 1 setManifold part no.

VQ1100-51 ......................... 2 setsValve part no. (Stations 1 to 2)


VQ1200-51 ......................... 2 setsValve part no. (Stations 3 to 4)
VVQ1000-J1-51-A ............... 1 setEjector valve part no.
ZSE1-00-15CL .................... 1 setVacuum switch part no.
Note 1) Count one ejector unit as one manifold station.
Note 2) The ejector unit is mounted next to the U-side end plate.
Note 3) The U-side end plate is used exclusively for ejector units. (Without P and
R port)
Note 4) The dimension of manifold with an ejector unit is different from the
standard dimension. See the formula for calculating the dimensions for
each kit.

Page 1

Base Mounted Plug-in Unit

Series VQ1000

VVQ1000

J 1

5 C 1

F kit

How to Order Ejector Valves

A
Specifications

Function
B

Nil

B
K
N

Standard

DC
(0.4 W)

AC

Coil voltage

Note 1)

1
2
3
4
5
6

High-speed (0.95 W)
response type
High-pressure type (0.95 W)

(0.8 MPa)
Negative
common

Note 1) For power consumption of AC type, refer to page 16.


Note 2) When two or more symbols are specified, indicate
them alphabetically. Combination of [B] and [K] is
not possible.

100 VAC (50/60 Hz)


200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC

Manual override
Nil

B
C
D

Non-locking push type


Locking type (Tool required)
Locking type (Manual)
Slide locking type (Manual)

Manifold
1

G kit

Symbol Specifications

Symbol Nozzle diameter Vacuum release valve


A
0.7
With
B
1.0

P kit

10.1.14 2:22 PM

J kit

VQ-A.qxd

Plug-in unit

How to Order Vacuum Pressure Switches

Wiring specifications
Nil

L
C
CL
CN

Grommet type, Lead wire length 0.6 m


Grommet type, Lead wire length 3 m
Connector type, Lead wire length 0.6 m
Connector type, Lead wire length 3 m
Without connector Note)

Note) When ordering the switch with 5 m lead wire length,


order separately the switch without connector and the
connector. (Refer to the below.) Besides, refer to the
Vacuum Equipment catalog CAT.100 for details.

How to Order Connectors

Without lead wire (Connector 1 pc., Socket 4 pcs.) ZS-20-A


With lead wire ZS-20-5A-50

Lead wire length (m)


Nil

30
50

Flow/Exhaust Characteristics of Ejector Unit


Nozzle Diameter 0.7
Exhaust Characteristics

L kit

1 setting, Without analog output, 3 revolution adjustment


1 setting, Without analog output, 200 adjustment
2 setting, Without analog output, 3 revolution adjustment
2 setting, Without analog output, 200 adjustment
1 setting, With analog output, 3 revolution adjustment
1 setting, With analog output, 200 adjustment

0.6
3
5

M kit

14
15
16
17
18
19

(The flow characteristics are for the supply pressure of 0.5 MPa.)

Flow Characteristics

Semistandard
Construction
Exploded
View of
Manifold

Suction flow rate

Vacuum pressure (mmHg)

Suction flow rate Nl/min

Supply pressure (MPa)

Nozzle Diameter 1.0


Exhaust Characteristics

Flow Characteristics

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Vacuum pressure (mmHg)

Suction flow rate Nl/min


Air consumption Nl/min

Vacuum pressure
Air consumption

Supply pressure (MPa)

Vacuum pressure (mmHg)

Vacuum pressure (mmHg)

Suction flow rate

Suction flow rate Nl/min


Air consumption Nl/min

Vacuum pressure
Air consumption

S kit

Switch spec./Voltage (Solid state: 12 to 24 VDC)

T kit

15 CL

Sub-plate
Single Unit

ZSE1 00

Suction flow rate Nl/min

70

VQ-A.qxd

09.2.26 2:37 PM

Page 72

Series VQ2000
VQ2000: Manifold Optional Parts
Blanking plate assembly JIS symbol
VVQ2000-10A-1
It is used by attaching on the manifold block for being
prepared for removing a valve for maintenance reasons
or planning to mount a spare valve, etc.

Individual SUP spacer


VVQ2000-P-1- C8
N9
When the same manifold is to be used for different
pressures, individual SUP spacers are used as SUP
ports for different pressures. (One station space is occupied.)
Block both sides of the station, for which the supply
pressure from the individual SUP spacer is used, with
SUP block plates. (Refer to the application example.)
Specify the spacer mounting position and SUP block plate
position by means of the manifold specification sheet. The
block plate is used in one or two places for one set.
(Two SUP block plates for blocking SUP station are
attached to the individual SUP spacer.)
As a standard, electric wiring is connected to the position of the manifold station where the individual SUP
spacer is mounted.
If wiring is not required for stations equipped with
spacers, enter X in the special wiring specifications
column in the manifold specification sheet.

Individual EXH spacer


VVQ2000-R-1- C8
N9
When valve exhaust affects other stations due to the
circuit configuration, this spacer is used for individual
valve exhaust. (One station space is occupied.)
Block both sides of the individual valve EXH station.
(Refer to the application example.)
Specify the mounting position, as well as the EXH
block base or EXH block plate position by means of
the manifold specification sheet.
The block plate is used in one or two places for one
set. (Two EXH block plates for blocking EXH station
are attached to the individual EXH spacer.)
As a standard, electric wiring is connected to the position of the manifold station where the individual EXH
spacer is mounted.
If wiring is not required for stations equipped with
spacers, enter X in the special wiring specifications
column in the manifold specification sheet.

SUP block plate

Individual SUP spacer


C8 (SUP port)
C8: 8 one-touch fitting

D side

Valve

SUP block plate

Individual Valve
SUP spacer

Valve

U side

Block indication label


A label indicating the SUP passage
blocking position is to be adhered.

ide

Us

SUP block plate

ide

Ds

EXH block plate

Individual EXH spacer


D side

Valve

EXH block plate

Individual Valve
EXH spacer

Valve

U side

C8 (EXH port)
C8: 8 one-touch fitting

ide

EXH block
plate

Us

ide
D s Block indication label
A label indicating the EXH passage
blocking position is to be adhered.

SUP block plate


VVQ2000-16A

Block indication label

When different pressures are supplied to a manifold, a


SUP block plate is used to block the stations under
different pressures.

ide

Us

Specify the mounting position by means of the manifold specification sheet.

ide

Ds

<Block indication label>


Indication labels to confirm the blocking position are
attached. (Each for SUP passage and SUP/EXH
passage blocking positions)

When ordering a block plate incorporated


with a manifold, a block indication label is
attached to the manifold.

SUP passage blocked

SUP/EXH passage blocked

EXH block plate


VVQ2000-19A
The EXH block plate is used between stations for
which exhaust is desired to be divided when valve
exhaust affects other stations configuration. It is also
used in combination with an individual EXH spacer for
individual exhaust.

Block indication label

ide

Us
2 pcs. in 1 set

Specify the mounting position by means of the manifold specification sheet.

ide

Ds

When ordering a block plate incorporated


with a manifold, a block indication label is
attached to the manifold.

<Block indication label>


Indication labels to confirm the blocking position are
attached. (Each for EXH passage and SUP/EXH
passage blocking positions)
EXH passage blocked

71

SUP/EXH passage blocked

VQ-A.qxd

09.2.26 2:37 PM

Page 73

Base Mounted Plug-in Unit

Series VQ2000

F kit

SUP stop valve spacer


VVQ2000-24A-1
A SUP stop valve spacer is mounted on a manifold block,
making it possible to individually shut off supply air to each
valve.
Enclosure: Dust-tight, Water-jet-proof (IP65) compliant

15.8

92.5

PUSH

J kit

LOCK

1
(P)

G kit

9.6

21.5

26.8

P kit

78.8

4(A)

Single valve

T kit

2(B)

L kit

5 3
(R1) (R2)

Name plate [-N]


VVQ2000-N-Station (1 to Max. stations)

Semistandard

1. The back pressure check valve


assembly is assembly parts with a
check valve structure. However,
since the valve has slight air leakage, take precautions for the exhaust air not to be restricted at the
exhaust port.
2. When a back pressure check
valve is mounted, the effective
area of the valve will decrease by
about 20%.

P = 16

It is a transparent resin plate for placing a label that


indicates solenoid valve function, etc.
Insert it into the groove on the side of the end plate and
bend it as shown in the figure.
When ordering this option incorporated with a manifold, suffix -N to the end of the manifold part number.

KQ2P-
It is inserted into an unused
cylinder port and SUP/EXH ports.
Purchasing order is available in
units of 10 pieces.

Construction

n: Stations

Exploded
View of
Manifold

Blanking plug (For one-touch fittings)

Sub-plate
Single Unit

(Precautions)

It prevents cylinder malfunction caused by other valve exhaust


entry. Insert it into R (EXH) port on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is
used or an exhaust center type solenoid valve is used.
When ordering assemblies incorporated with a manifold, add
suffix -B to the end of the manifold part number.
Note) When a check valve for back pressure prevention is desired and is to be installed only in certain manifold stations, clearly indicate the part number and specify the
mounting position by means of the manifold specification sheet.

M kit

2 pcs. in 1 set

Dimensions
Applicable
fitting size
d

Model

Applicable
fitting size
d

Model

4
6
8
10

KQ2P-04
KQ2P-06
KQ2P-08
KQ2P-10

16
18
20.5
22

32
35
39
43

6
8
10
12

5/32"
1/4"
5/16"
3/8"

KQ2P-03
KQ2P-07
KQ2P-09
KQ2P-11

16
18
20.5
22

32
35
39
43

6
8.5
10
11.5

Port plug
VVQ1000-58A
The plug is used to block the cylinder port.
When ordering a plug incorporated with a manifold,
indicate CM for the port size of the manifold part
number, as well as, the mounting position and number of stations and cylinder port mounting positions, A
and B by means of the manifold specification sheet.

72

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Back pressure check valve assembly [-B]


VVQ2000-18A

S kit

<Circuit diagram>
(Example of a spacer
with a built-in single valve)

VQ-A.qxd

09.2.26 2:37 PM

Page 74

Series VQ2000
VQ2000: Manifold Optional Parts
DIN rail mounting bracket [-D/-D0/-D]
VVQ2000-57A
It is used for mounting a manifold on a DIN rail.
When ordering this option incorporated with a manifold, suffix -D to the end of the manifold part number.

1 set of DIN rail mounting bracket is used for 1 manifold


(2 DIN rail mounting brackets).

DIN rail clamp screw

Direct EXH outlet with built-in silencer [-S]


Exhaust

This is a type with an exhaust port atop the manifold


end plate. The built-in silencer exhibits an excellent
noise suppression effect. (Noise reduction: 30 dB)
When ordering this option incorporated with a manifold, suffix -S to the end of the manifold part number.
Note) A large quantity of drainage generated in the
air source results in exhaust of air together
with drainage.
 Refer to back page 5 for maintenance.

Silencer (For EXH port)


This silencer is to be inserted into the EXH port (Onetouch fittings).

Dimensions
Series
VQ2000

Effective

Applicable
fitting size
d

Model

10

AN200-KM10

59.6 80.8

Noise

D area (mm2) reduction


22

(Cv factor)

(dB)

26 (1.4)

30

Elbow fitting assembly


VVQ2000-F-L(C4/C6/C8/N3/N7/N9)

Dual flow fitting assembly


VVQ2000-52A-C10
N11
This is a fitting to multiply the flow rate by combining
the outputs of 2-valve stations. It is used for driving a
large bore cylinder. This is a one-touch fitting for a port
size of 10 or 3/8".

73

It is used for piping that extends upward or downward


from the manifold.
When not installed in the manifold stations, specify the
assembly part number and the mounting position by
means of the manifold specification sheet.

The port size for the manifold part number is CM.


Clearly indicate the dual flow fitting assembly part number and specify the mounting position by
means of the manifold specifications.

VQ-A.qxd

09.2.26 2:37 PM

Page 75

Series VQ2000

Base Mounted Plug-in Unit

Manifold Option

F kit

Double check block (Separated) for VQ2000


<Circuit diagram>

VQ2000-FPG--
It is mounted on the outlet side piping to keep the cylinder in the intermediate
position for a long time. Combining the double check block with a 3-position exhaust
center solenoid valve will enable the cylinder to stop in the middle or maintain its
position for long periods of time.
The combination with a 2-position single/double solenoid valve will prevent the
dropping at the cylinder stroke end when the SUP residual pressure is released.
IN

P kit

Cylinder side
pressure (P2)

IN

Specifications
0.8 MPa
0.15 MPa
5 to 50C
3.0 dm3/(sbar)
180 c.p.m

To

CY

Lp

SUP side
pressure (P1)

ort

4
A

L kit

( 9.5)
3

Stations
D side
2 x Rc 1/8, 1/4, C6, C8
C6: 6 one-touch fitting assembly
C8: 8 one-touch fitting assembly

2 x Rc 1/8, 1/4, C6, C8


C6: 6 one-touch fitting assembly
C8: 8 one-touch fitting assembly

B
2
4

B
2

U side

M kit

58
(59.5)

B
2

25
45
65.5

20.5

9.5)

37.5

80

S kit

5.5
2

58

69.5
(5)

10.5

( 9.5)

39.5

80

6.5
(40)

IN
(For C6, C8)

Residual pressure
release manual
override

Residual pressure release


manual override

(41.5)

IN

(33)

IN

22

IN

( 9.5)

(For C6, C8)

23 P = 22

2 x M6 mounting hole

Sub-plate
Single Unit

A
B

DIN rail
clamp screw

2 x M4 mounting hole

(For C6, C8)

4
2

L3
L2
L1

(For C6, C8)

2 x Rc 1/8, 1/4, C6, C8


C6: 6 one-touch fitting assembly
C8: 8 one-touch fitting assembly

2 x Rc 1/8, 1/4, C6, C8


C6: 6 one-touch fitting assembly
C8: 8 one-touch fitting assembly
4.5

G kit

25
45

4
A

Manifold

Single unit

17.5
(1.5)
37.5

Dimensions

L n

Formula L1 = 22n + 24

10

11

12

13

14

n: Station

15

Semistandard

Dimensions

(1.5)

16

90 112 134 156 178 200 222 244 266 288 310 332 354 376
L1 46 68
L2 75 87.5 112.5 137.5 162.5 175 200 225 250 262.5 287.5 312.5 337.5 362.5 375 400
L3 85.5 98 123 148 173 185.5 210.5 235.5 260.5 273 298 323 348 373 385.5 410.5

Construction

17.5

7.5

37.5

How to Order
Double check block
01

IN side port size


01
02
C6
C8
N7
N9

Rc 1/8
Rc 1/4
6 one-touch fitting
8 one-touch fitting
1/4" one-touch fitting
5/16" one-touch fitting

<Example>
Option

F
OUT side port size
01
02
C6
C8
N7
N9

Rc 1/8
Rc 1/4
6 one-touch fitting
8 one-touch fitting
1/4" one-touch fitting
5/16" one-touch fitting

None

DIN rail mounting


(For manifold)

F
N

With bracket
Name plate

Note) When two or more symbols


are specified, indicate them
alphabetically.
Example) -DN

Drop
prevention

Intermediate
stops

Caution

Manifold (DIN rail mounting)


VVQ2000-FPG- 06
Stations
When ordering a double check block,
order the DIN rail mounting [-D].

Nil

Exploded
View of
Manifold

VQ2000-FPG- 01

T kit

Note) Based on JIS B 8375-1981


(Supply pressure: 0.5 MPa)

J kit

01

1 station

16 16 stations
<Ordering Example>
VVQ2000-FPG-06...6-station manifold
VQ2000-FPGBracket Assembly
C6C6-D, 3 sets
Double
Tightening torque
Part no.
VQ2000-FPG- check block
C8C8-D, 3 sets
VQ2000-FPG-FB 0.8 to 1.0 Nm

Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from
stopping for long periods of time. Check the leakage using neutral household detergent, such as dish
washing soap. Also check the cylinders tube gasket, piston packing and rod packing for air leakage.
Since one-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in
the middle for long periods of time.
Combining double check block with 3-position closed center or pressure center solenoid valve will not work.
When fittings, etc. are being screwed to the double check block, tighten them with the torque below.

Connection threads
Rc 1/8
Rc 1/4

Proper tightening torque (Nm)


7 to 9
12 to 14

If the exhaust of the double check block is restricted too much, the cylinder may not operate properly and
may not stop intermediately.
Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.

74

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Max. operating pressure


Min. operating pressure
Ambient and fluid temp.
Flow characteristics: C
Max. operating frequency

VQ-A.qxd

09.2.26 2:37 PM

Page 76

Series VQ2000
Manifold Option
Double check block (Direct mounting)

VVQ2000-23A- BC 68

<Check valve operation principle>

It is mounted directly on the manifold to keep the cylinder in the intermediate position
for a long time. Combining the double check block with a built-in pilot type double
check valve and a 3-position exhaust center solenoid valve will enable the cylinder to
stop in the middle or maintain its position for long periods of time.
The combination with a 2-position single/double solenoid valve will permit this block
to be used for preventing the dropping at the cylinder stroke end when the SUP
residual pressure is released.

Cylinder side
pressure (P2)

Specifications
Max. operating pressure

0.7 MPa

Min. operating pressure

0.15 MPa
5 to 50C

Ambient and fluid temperature

SUP side
pressure (P1)

1.8 dm3/(sbar)

Flow characteristics: C

180 c.p.m

Max. operating frequency

Dimensions
Single unit

When the manifold is mounted.

15.8

Residual pressure release


Manual override

180.2
80

180.2

120

20

120

55

65

15

2 x port on the OUT side


C6: With 6 one-touch fitting (for top ported)
C8: With 8 one-touch fitting (for top ported)
B6: With 6 one-touch fitting (for bottom ported)
B8: With 8 one-touch fitting (for bottom ported)

22

10

85
<Recommended
hole dimension>

Top ported (VVQ2000-23A-C)

Residual pressure release


Manual override

Color: red

Caution
Air leakage from the pipe between the valve and cylinder or from the fittings will
prevent the cylinder from stopping for long periods of time. Check the leakage using
neutral household detergent, such as dish washing soap.
Also check the cylinders tube gasket, piston packing and rod packing for air
leakage.
Since zero air leakage is not guaranteed, it is sometimes not possible to hold a stop
position for long periods of time.
Combining double check block with 3-position closed center or pressure center
solenoid valve will not work.
Set the cylinder load so that the cylinder pressure will be within two times that of
the supply pressure.
If the exhaust of the double check block is restricted too much, the cylinder may not
operate properly and may not stop intermediately.

<Example>
2-position
5(R1)
1(P)
3(R2)

3-position exhaust center


5(R1)
1(P)
3(R2)

Drop
prevention

5(R1)
1(P)
3(R2)

5(R1)
1(P)
3(R2)

Intermediate
prevention
2(B) 4(A)

75

Bottom ported (VVQ2000-23A-B)

2(B) 4(A)

VQ-A.qxd

09.2.26 2:37 PM

Page 77

VQ-A.qxd

09.2.26 2:37 PM

Page 78

Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of Caution, Warning or
Danger. They are all important notes for safety and must be followed in addition to International
Standards (ISO/IEC), Japan Industrial Standards (JIS)1) and other safety regulations2).
1) ISO 4414: Pneumatic fluid power General rules relating to systems.
ISO 4413: Hydraulic fluid power General rules relating to systems.
IEC 60204-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements)
ISO 10218-1992: Manipulating industrial robots - Safety.
JIS B 8370: General rules for pneumatic equipment.
JIS B 8361: General rules for hydraulic equipment.
JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements)
JIS B 8433-1993: Manipulating industrial robots Safety.
etc.
2) Labor Safety and Sanitation Law, etc.

Caution:
Warning:
Danger :

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or
moderate injury.
Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or
serious injury.
Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious
injury.

Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment
or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be
decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined
its compatibility with the product. This person should also continuously review all specifications of the product referring to its
latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.

2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or
equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or
runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power
from any appropriate source is cut, and read and understand the specific product precautions of all relevant products
carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to
be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military,
medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits,
clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard
specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective
function, and periodical checks to confirm proper operation.

Back page 1

F kit

Page 79

1. The product is provided for use in manufacturing industries.


The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange specifications or a
contract if necessary.
If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/Compliance Requirements


The product used is subject to the following Limited warranty and Disclaimer and Compliance
Requirements.
Read and accept them before using the product.

G kit

Caution

J kit

P kit

Safety Instructions

T kit

09.2.26 2:37 PM

L kit

VQ-A.qxd

Compliance Requirements

M kit
Sub-plate
Single Unit
Semistandard
Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade
and Industry (Foreign Exchange and Foreign Trade Control Law).

Construction

3) Vacuum pads are excluded from this 1 year warranty.


A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the
deterioration of rubber material are not covered by the limited warranty.

Exploded
View of
Manifold

1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.3)
Also, the product may have specified durability, running distance or replacement parts. Please
consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility,
a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage
incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers
noted in the specified catalog for the particular products.

S kit

Limited warranty and Disclaimer

Back page 2

VQ-A.qxd

09.2.26 2:37 PM

Page 80

Series VQ1000/2000

Specific Product Precautions 1


Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC
Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

Light/Surge Voltage Suppressor

Manual Override

Caution

Warning

The lighting positions are concentrated on one side


for both single solenoid type and double solenoid
type. In the double solenoid type, A side and B side
energization are indicated by two colors which match
the colors of the manual overrides.

 Push type (Tool required)


Bore 3.2

Manual override:
Orange
(Drawing shows a VQ1000 case.)

Double solenoid
Indicator light
A: Orange
B: Green

VQ1000

Stop diode

Bore 3.2

Stop diode

Surge absorption
diode

Bore 4.2

Push down on the manual


override with a flat head
screwdriver until it stops.
Turn it clockwise by 90 to
lock it. Turn it counterclockwise to release it.

VQ2000

 Locking type (Manual) <Semi-standard>


10 mm

Light

Note) A-side energization:


With wrong wiring prevention (stop
A light (Orange) illuminates. diode) mechanism
B-side energization:
B light (Green) illuminates.

VQ2000

Double solenoid

VQ1000
Light
Surge absorption
diode

Push down on the manual


override with a small screwdriver, etc. until it stops. Release the screwdriver and the
manual override will return.

 Locking type (Tool required) <Semi-standard>

DC circuit diagram
Single solenoid

Bore 4.2

Single solenoid

Indicator light:
Orange

With a surge absorption (surge


absorption diode) mechanism

11 mm

Manual override:
Green

Without an electric signal for the solenoid valve the


manual override is used for switching the main valve.
Push type is standard. (Tool required) Locking type is
semi-standard. (Tool required/Manual)

VQ1000

Push down on the manual


override with a small flat
head screwdriver or with your
fingers until it stops. Turn it
clockwise by 90 to lock it.
Turn it counterclockwise to
release it.

VQ2000

Caution
Do not apply excessive torque when turning the locking type manual
override. (0.1 Nm or less)

Back page 3

VQ-A.qxd

09.2.26 2:37 PM

Page 81

Series VQ1000/2000
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC
Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

How to Mount/Remove Solenoid Valves

Warning

P kit

Manual Override

Caution

 Slide locking type (Manual) <Semi-standard>

ON

Green
ON position

Caution
Dust on the sealing surface of the gasket or solenoid valve can cause
air leakage.

T kit

OFF

G kit

1. Press down on the clamp screw. Clamp bracket A opens. Diagonally insert the hook on the valve end plate side into clamp
B.
2. Press the valve body downward. (When the screw is released,
it will be locked by clamp bracket A.)
3. Tighten the clamp screw. (Proper tightening torque: VQ1000,
0.25 to 0.35 Nm; VQ2000, 0.5 to 0.7 Nm.)

J kit

Mounting

Bore 1.7

Orange
OFF position

F kit

Specific Product Precautions 2

Replacement of Cylinder Port Fittings

VQ1000

Clip
Fitting assembly

Orange
OFF position

VQ2000

Fittings
assembly

The manual override is locked by sliding it all the way to the pilot
valve side (ON side) with a small flat head screwdriver or finger.
Slide it to the fitting side (OFF side) to release it. In addition, it
can also be used as a push type by using a screwdriver, etc., of
1.7 or less. (2 or less for VQ2000).

How to Mount/Remove Solenoid Valves

Caution

Clip

Applicable tubing O.D.


Applicable tubing 3.2
Applicable tubing 4
Applicable tubing 6
Applicable tubing 8
M5
Applicable tubing 1/8"
Applicable tubing 5/32"
Applicable tubing 1/4"
Applicable tubing 5/16"

VQ1000

VQ2000
Fitting assembly part no.

VQ1000
VVQ1000-50A-C3
VVQ1000-50A-C4
VVQ1000-50A-C6
VVQ1000-50A-M5
VVQ1000-50A-N1
VVQ1000-50A-N3
VVQ1000-50A-N7

VQ2000
VVQ1000-51A-C4
VVQ1000-51A-C6
VVQ1000-51A-C8

VVQ1000-51A-N3
VVQ1000-51A-N7
VVQ1000-51A-N9

B
A

B
A

Refer to Manifold Optional Parts on pages 66, 67, 73 for other types of fittings.
Clamp bracket A
Clamp screw
Clamp bracket B

Removing
1. Loosen the clamp screw until it turns freely. (The screw is captive.)
2. Lift the coil side of the valve body while pressing down slightly
on the screw head and remove it from the clamp bracket B.
When the screw head cannot be pressed easily, gently press
the area near the manual override of the valve.

Caution
1. Use caution that O-rings must be free from scratches and dust. Otherwise, air leakage may result.
2. After screwing in the fittings, mount the M5 fitting assembly on the
manifold base. (Tightening torque: 0.8 to 1.2 Nm)
3. Purchasing order is available in units of 10 pieces.

Back page 4

M kit
Sub-plate
Single Unit

Green
ON
position

ON

Semistandard

OFF

Construction

Bore 2

The cylinder port fittings are a cassette for easy replacement. The fittings are blocked by a clip. Take out
the clip with a flat head screwdrier, etc., then replace
the fittings.
For mounting, insert the fitting assembly until it
strikes against the inside wall and then insert the clip
to the specified position.

Exploded
View of
Manifold

ON

Specific
Safety
Manifold
Product
Instructions Optional Parts
Precautions

Caution

OFF

S kit

L kit

Bore 2

VQ-A.qxd

09.2.26 2:37 PM

Page 82

Series VQ1000/2000

Specific Product Precautions 3


Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC
Products (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.

How to Mount/Remove DIN Rail

Caution

Caution
A filter element is incorporated in the end plate on both sides of
the maifold base. A dirty and choked element may reduce cylinder speed or cause malfunction. Clean or replace the dirty element.

Removing
1. Loosen the clamp
screw on side (a)
of the end plate
on both sides.
2. Lift side (a) of the
manifold base and
slide the end plate
in the direction of
(2) shown in the
figure to remove.

Element Part No.


Element part no.

Type
(2)

Built-in silencer,
direct exhaust

VQ1000

VQ2000

VVQ1000-82A-1

VVQ2000-82A-1

The minimum order quantity is 10 pcs.

End plate

(1) (a)

Remove the cover from the


top of the end plate and
remove the old element with
a flat head screwdriver, etc.

Mounting
1. Hook side (b) of
the manifold base
on the DIN rail.
2. Press down side
(a) and mount the
end plate on the
DIN rail. Tighten
the clamp screw
on side (a) of the
end plate. The
proper tightening
torque for screws
is 0.4 to 0.6 Nm.

Built-in Silencer Element

(b)
(1)

Hook

(2)

(a)

IP65 Enclosure

Caution
Wiring connection for models conforming to IP65 should also
have enclosures equivalent to or of stricter than IP65.

How to Calculate Flow Rate


Refer to Best Pneumatics No. q for obtaining the flow rate.

Back page 5

VQ-A.qxd

09.2.26 2:37 PM

Page 83

VQ-A.qxd

09.2.26 2:37 PM

Page 84

SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK

EUROPE
AUSTRIA
SMC Pneumatik GmbH (Austria)
BELGIUM
SMC Pneumatics N.V./S.A.
BULGARIA
SMC Industrial Automation Bulgaria Eood
CROATIA
SMC Industrijska Automatika d.o.o.
CZECH REPUBLIC
SMC Industrial Automation CZ s.r.o.
DENMARK
SMC Pneumatik A/S
ESTONIA
SMC Pneumatics Estonia O
FINLAND
SMC Pneumatics Finland Oy
FRANCE
SMC Pneumatique SA
GERMANY
SMC Pneumatik GmbH
GREECE
SMC Hellas E.P.E.
HUNGARY
SMC Hungary Ipari Automatizlsi Kft.
IRELAND
SMC Pneumatics (Ireland) Ltd.
ITALY
SMC Italia S.p.A.
LATVIA
SMC Pnuematics Latvia SIA
LITHUANIA
UAB SMC Pneumatics

NETHERLANDS
SMC Pneumatics B.V.
NORWAY
SMC Pneumatics Norway AS
POLAND
SMC Industrial Automation Polska Sp.z.o.o.
ROMANIA
SMC Romania S.r.l.
RUSSIA
SMC Pneumatik LLC
SLOVAKIA
SMC Priemyseln Automatizcia Spol s.r.o.
SLOVENIA
SMC Industrijska Avtomatika d.o.o.
SPAIN/PORTUGAL
SMC Espaa S.A.
SWEDEN
SMC Pneumatics Sweden AB
SWITZERLAND
SMC Pneumatik AG
U.K.
SMC Pneumatics (U.K.) Ltd.

ASIA
CHINA
SMC (China) Co., Ltd.
HONG KONG
SMC Pneumatics (Hong Kong) Ltd.
INDIA
SMC Pneumatics (India) Pvt. Ltd.
MALAYSIA
SMC Pneumatics (S.E.A.) Sdn. Bhd.
PHILIPPINES
Shoketsu SMC Corporation

SINGAPORE
SMC Pneumatics (S.E.A.) Pte. Ltd.
SOUTH KOREA
SMC Pneumatics Korea Co., Ltd.
TAIWAN
SMC Pneumatics (Taiwan) Co., Ltd.
THAILAND
SMC (Thailand) Ltd.

NORTH AMERICA
CANADA
SMC Pneumatics (Canada) Ltd.
MEXICO
SMC Corporation (Mexico), S.A. de C.V.
U.S.A.
SMC Corporation of America

SOUTH AMERICA
ARGENTINA
SMC Argentina S.A.
BOLIVIA
SMC Pneumatics Bolivia S.r.l.
BRAZIL
SMC Pneumticos do Brasil Ltda
CHILE
SMC Pneumatics (Chile) S.A.
VENEZUELA
SMC Neumatica Venezuela S.A.

OCEANIA
AUSTRALIA
SMC Pneumatics (Australia) Pty. Ltd.
NEW ZEALAND
SMC Pneumatics (N.Z.) Ltd.

Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.

Akihabara UDX 15F,


4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
2009 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.

D-DN

1st printing NP printing NP 16400DN Printed in Japan.

This catalog is printed on recycled paper with concern for the global environment.

You might also like