ZXMW NR8120A/8120D

Digital Microwave Transmission System

Configuration Guide
Version: V2.04.02

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: 800@zte.com.cn

LEGAL INFORMATION
Copyright 2016 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.

Additionally, the contents of this document are protected by

contractual confidentiality obligations.


All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit the ZTE technical support website http://support.zte.com.cn to inquire for related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision No.

Revision Date

R1.1

2015-10-23

Revision Reason
Modify Configuring Ethernet Ports: add the steps of querying
the port status.

R1.0

2015-10-16

First Edition

Serial Number: SJ-20150804150350-005


Publishing Date: 2015-10-23 (R1.1)

SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

About This Manual


Purpose
This manual provides information about configuring the ZXMW NR8120A/8120D Digital
Microwave System on the Local Maintenance Terminal (LMT).
Take the ZXMW 8120D as an example.

Intended Audience
This manual is intended for:
l
l

Commissioning engineers
Maintenance engineers

What Is in This Manual


This manual contains the following chapters:
Chapter 1, Preparations

Describes the preparations before the ZXMW NR8120A/8120D


configuration.

Chapter 2, NE Basic Data

Describes the configuration flow and configuration example of ZXMW

Configuration

NR8120A/8120D NE basic data.

Chapter 3, Radio Link Data

Describes the configuration flow and configuration example of ZXMW

Configuration

NR8120A/8120D radio link data.

Chapter 4, TDM Service

Describes the configuration flow and configuration example of ZXMW

Data Configuration

NR8120A/8120D TDM service data.

Chapter 5, Ethernet Service

Describes the configuration flow and configuration example of ZXMW

Data Configuration

NR8120A/8120D Ethernet service data.

Chapter 6, Clock Data

Describes the configuration flow and configuration example of ZXMW

Configuration

NR8120A/8120D clock data.

Chapter 7, Other

Describes the operation procedures of other service configuration

Configuration Operation

on the LMT.

Chapter 8, Configuration

Describes the configuration check items.

Check

Conventions
This manual uses the following conventions.

I
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Danger: indicates an imminently hazardous situation. Failure to comply can result in


death or serious injury, equipment damage, or site breakdown.
Warning: indicates a potentially hazardous situation. Failure to comply can result in
serious injury, equipment damage, or interruption of major services.
Caution: indicates a potentially hazardous situation. Failure to comply can result in
moderate injury, equipment damage, or interruption of minor services.
Note: provides additional information about a topic.

II
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 1

Preparations
Table of Contents
Preparing Tools and Software.....................................................................................1-1
Logging in to the Web LMT.........................................................................................1-1
Checking Versions......................................................................................................1-4

1.1 Preparing Tools and Software


Prepare a computer that meets the following configuration requirements:
l

Operating system:

Microsoft Windows XP

Microsoft Windows 7

Web browser: Microsoft Internet Explorer 6.0, 7.0 or 8.0. Internet Explorer 8.0 is
recommended.

1.2 Logging in to the Web LMT


Users can log in to the Web Local Maintenance Terminal (LMT) by using either of the
following methods:
l Log in through the RCMUC/RCMUD boards' LMT interface, which has an initial IP
address of 192.168.1.16. The IP address can be modified after login through the LMT
interface.
l Log in through the RCMUC/RCMUD boards' network management system (NMS)
interface, which has an IP address that is the same as that of the NE.

Context
The second method of logging in to the Web LMT helps log in to the entire network
management system, which is NetNumen M31 (MW). Before using the second method to
log in to the Web LMT, users must use the first method to log in to the Web LMT once.
The detailed procedures are described as follows:
1. Log in to the Web LMT through the RCMUC/RCMUD boards' LMT interface.
2. In the left pane, select Setup > System > Parameter. The system parameter
configuration page is displayed.
3. Modify the IP address, which should be unique in the entire network.
4. Log in to Web LMT through the RCMUC/RCMUD boards' NMS interface.
The following describes how to log in to the Web LMT by using the first method.
1-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Steps
1. Right-click the My Network Places icon on the desktop, and click Properties from the
shortcut menu. Right-click the local connection icon, and click Properties, see Figure
1-1.
Figure 1-1 Local Area Connection Properties Dialog Box

2. Double-click Internet Protocol (TCP/IP). In the Internet Protocol (TCP/IP)


Properties dialog box, select Obtain an IP address automatically, see Figure 1-2.

1-2
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 1 Preparations

Figure 1-2 Internet Protocol (TCP/IP) Properties Dialog Box

3. Click OK.
4. Use an Ethernet cable to connect the LMT interface of the IDU's RCMUC/RCMUD
with the PC.

Note:
This is the method of logging in through the RCMUC/RCMUD board's LMT interface.
For the method of logging in through the RCMUC/RCMUD board's NMS interface, you
should connect the NMS interface to the PC.
You must enable the NMS interface before using it, because this interface is disabled
by default.

5. Run the Internet Explorer. Enter the IP address of the IDU's LMT interface, for
example, http://192.168.1.16, and press Enter. The Web LMT login dialog box is
displayed, see Figure 1-3.

1-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 1-3 Web LMT Login Dialog Box

6. Enter the user name in User Name and the password in Password. Then, click
LOGIN. After the login succeeds, the system interface is displayed, see Figure 1-4.
Figure 1-4 Web LMT Home Page (ZXMW 8120D)

End of Steps

1.3 Checking Versions


This procedure describes how to check IDU ,ODU and AOU versions and update them if
required.

1-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 1 Preparations

Steps
1. In the left pane, select Maintenance > Version > IDU Version.
2. Check the IDU version in the Version Management area, see Figure 1-5.
Figure 1-5 IDU Version

Note:
Package status description:
l
l
l

The RUNNING status indicates a running IDU version.


The VALID status indicates an activated backup IDU version.
The NOT VALID status indicates a backup IDU version that is not activated.

3. Click the Query button in the Hardware Version Information area, see Figure 1-6.
Figure 1-6 Hardware Version Information

4. In the left pane, select Maintenance > Version > ODU.


5. Check the ODU version in the right pane, see Figure 1-7.

1-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 1-7 ODU Version

6. Ensure that the IDU, ODU and AOU versions are correct. If not, update the versions.

Note:
It is unnecessary to update the ODU version manually. The system will update the
ODU version to the latest automatically.

End of Steps

1-6
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 2

NE Basic Data Configuration


Step

Configuration

Description

Configure the NE name and IP address.

Required
For the configuration procedure, refer to 2.1
Configuring the NE Information.

Configure the NE time and time zone.

Required
For the configuration procedure, refer to 2.2
Configuring the NE Time.

Configure the connection between the

Required

NE and NMS.

For the configuration procedure, refer to 2.3


Configuring the NMS.

Configure AOU host.

Required if AOU is managed as an element


of IDU.
For the configuration procedure, refer to 2.4
Configuring AOU Host.

Table of Contents
Configuring the NE Information ..................................................................................2-1
Configuring the NE Time ............................................................................................2-4
Configuring the NMS ..................................................................................................2-8
Configuring AOU Host ..............................................................................................2-10

2.1 Configuring the NE Information


This section describes how to configure NE information, such as NE name and IP address.
An NE ID and NE IP address can identify an NE in a network. The NE IP address is
used for communication through Transmission Control Protocol (TCP)/IP. After the NE
information is configured, users can manage the NE through the NMS interface on the
RCMUC/RCMUD board.

Steps
1. In the left pane, select Setup > System > Parameter.
configuration page is displayed, see Figure 2-1.

The system parameter

2-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 2-1 System Parameter Configuration Page

2. Set the NE information. For a description of the parameters, refer to Table 2-1.
Table 2-1 System Parameter Description
Parameter

Value Range

Default

Description

Value
Site ID

Sets the site name. It can contain at most


100 characters, which cannot be <, >, &, '',
?, +, or \.

NE ID

165535

Configured in the NetNumen U31 Unified


Management System.

NE Name

zte

Sets the name of an NE. Usually, it is set


to the site name. It can contain at most 30
characters, including numbers, letters, and
symbols (@, (, ), -, _, and .), which cannot be
<, >, &, ?, +, or \.

NE Type

NR8120A

NR8120A or

Sets the equipment type. It is set to the default

NR8120D

NR8120D

value and cannot be modified.

2-2
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 2 NE Basic Data Configuration

Parameter

Value Range

Default

Description

Value
Device IP

193.254.1.2

Address

Sets the IP address of an NE connected to


the Internet through the NMS interface. It can
be modified.
This parameter cannot be set to the following
values:
l

IP addresses that start with 127 or 192.


An IP address that starts with 127 is a
loopback address of the host, that is, an
IP address used by the NE to send IP
packets to itself. It is used for network
software tests and local inter-process
communication. An IP address that starts
with 192 is used for LMT port debugging.

Broadcast addresses
The IP addresses in which host
ID consists of all 1s are broadcast
addresses. For example, the broadcast
address for the 10.1.1.0/24 network
segment is 10.1.1.255.

Multicast addresses (from 224.0.0.0 to


239.255.255.255).

Device MAC

Sets the MAC address of the microwave NE.

Address

The value of this parameter is displayed


automatically and cannot be configured.

Subnet Mask

255.255.255

Sets the subnet mask of an NE. It is used

.0

with the Device IP Address parameter to


separate the IP address of an NE into two
parts: network address and host address.

193.254.1.1

Sets the default gateway for an NE. It is the IP

Default

IP addresses

Gateway

except those

address of an IP router that can be reached

start with 127 or

directly.

192, broadcast

When the NE sends a data packet, if there is

addresses,

no available gateway, the data packet is sent

and multicast

to the default gateway for processing.

addresses

2-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default

Description

Value
NE Health

No Alarm

Minor

No alarm

Displays the current device status.

Alarm
l

Major
Alarm

Critical
Alarm

After this task is completed, users can log in to the Web LMT through the
RCMUC/RCMUD's NMS interface (the NMS interface is On and enabled). The PC's
IP address and the NE's IP address must be configured in the same network segment.
3. Click Apply.
End of Steps

2.2 Configuring the NE Time


This procedure describes how to set the system time and time zone, which provides time
references for functions such as fault management and performance query. After the time
zone is changed, the system time is updated automatically.

Steps
Configuring the NE Time Zone
1. In the left pane, select Setup > System > Time. The system time configuration page
is displayed, see Figure 2-2.

2-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 2 NE Basic Data Configuration

Figure 2-2 System Time Management Page

2. In the Time Zone Management area, select System Time Zone or Custom Time
Zone. And select the time zone of the NE from the drop-down list, see Figure 2-3.
Figure 2-3 Time Zone Configuration Example

3. Click Apply.
Configuring the NE Time
4. Click the System Time text box in the System Time Management area. The calendar
is displayed, see Figure 2-4.

2-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 2-4 Configuring the System Time

5. In the System Time text box, move the cursor to the time part, delete the incorrect
time, and enter the accurate time in the form of HH:MM:SS.
6. Click Apply.
Configuring SNTP Management
7. In the SNTP Management area, configure the parameters. For a description of the
parameters, refer to Table 2-2.
Table 2-2 SNTP Management Parameters
Parameter

Value Range

Default Value

Description

SNTP Clock

Enable

Disable

Enables or disables the SNTP clock

Sync Service

Disable

Server IP

The server

Address

synchronization service.
192.168.1.1

Usually, an SNTP server is a

IP address

device with SNTP configuration.

cannot be the

The network management server

IP address of

is often used as SNTP server.

the NMS or

If the SNTP server is available,

Debug port.

time can be calibrated to ensure

The server

time consistency within the entire

IP address

network.

cannot be the
loopback IP
address (the
IP addresses
of 127.***.)
l

The server IP
address can
be A.x.x.x.
A must be
within the
2-6

SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 2 NE Basic Data Configuration

Parameter

Value Range

Default Value

Description

Sets the interval of server time

range from
0 to 224,
excluding 0
and 224.
Time Interval (h)

124

synchronization.
Timeout (s)

110

Sets the time of waiting for response


from the server during the process
of time calibration between a device
and the server. If the parameter
value expires, the system time is not
calibrated properly.

System Time

Displays the current system time.

8. Click Apply.
Configuring the DST Time
9. In the Summer Time Management area, configure the Daylight Saving Time (DST)
parameters. For a description of the parameters, refer to Table 2-3.
Table 2-3 Summer Time Management Parameters
Parameter

Value Range

Default Value

Description

Summer Time

Enable

Disable

The DST system is a local time

Disable

system used to save energy. In


areas where the DST system is
applied, the unified time used is
called summer time. In summer
when daybreak is earlier, time is
set one hour ahead of the standard
time. It helps reduce lighting cost
and make full use of sunlight.
Countries that use the DST system
have different regulations. Almost
110 countries use the DST system
every year around the world.

Start Time

MM: 112

(MM-dd HH:mm)

dd: 130 (31)

01-01 00:00

Sets the start time of the DST


system.

hh: 023
mm: 059

2-7
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default Value

Description

End Time

MM: 112

01-01 00:00

Sets the end time of the DST

(MM-dd HH:mm)

dd: 130 (31)

system.

hh: 023
mm: 059
Step (h)

110

The DST system can adjust the


current time according to the set
offset. For example, if Offset is set
to 1, the summer time is one hour
ahead of the standard time. In other
words, if the standard time is 10
a.m., the summer time is 11 a.m..

10. Click Apply.


End of Steps

2.3 Configuring the NMS


The ZXMW NR8120A/8120D manages microwave equipment remotely by using inband
network management mode. Users need to set Simple Network Management Protocol
(SNMP) IP parameters to add the Network Management System (NMS) IP address to the
IP address list.

Steps
1. In the left pane, select Setup > NMS. The NMS configuration page is displayed, see
Figure 2-5.

2-8
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 2 NE Basic Data Configuration

Figure 2-5 NMS VLAN and Bandwidth Configuration Example

2. Enter the network management VLAN ID, and then click Apply.
3. Select the required bandwidth, and then click Apply.
4. In the left pane, select Security > SNMP. The SNMP configuration page is displayed,
see Figure 2-6.
Figure 2-6 SNMP Configuration Page

5. From the Switch drop-down list, select ON or OFF.


l If OFF is selected, the system does not filter NMS IP addresses.
l If ON is selected, the system filters added NMS IP addresses. If there is no added
IP address, the system does not filter NMS IP addresses.
6. Click Add. The SNMP IP Address Configuration dialog box is displayed, see Figure
2-7.
2-9
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 2-7 SNMP IP Address Configuration Dialog Box

7. Enter the NMS name in the Name text box, enter the NMS IP address in the IP
Address text box, select Enable as the status, and then click Apply. Then, the NMS
IP address is added to the IP address list.
End of Steps

2-10
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 3

Radio Link Data


Configuration
Step

Configuration

Description

Configure the work mode.

Required.
For the configuration procedure, refer to 3.1 Configuring the
Work Mode.

Configure ODU

Required.

parameters.

For the configuration procedure, refer to 3.2 Configuring


ODU Parameters.

Configure the ATPC

Required if the interference of the ZXMW NR8120A/8120D to

function.

the adjacent system, DC power consumption, and influence


of level fading at the transmit end to the receive end need
to be reduced.
For the configuration procedure, refer to 3.3 Configuring the
ATPC Function.

Configure the ACM


function.

Required if the spectrum utilization needs to be improved to


increase system transmission capacity and guarantee reliable
transmission of high priority services.
For the configuration procedure, refer to 3.4 Configuring the
ACM Function.

Configure the PIS

Mandatory if Ethernet data priorities need to be determined

function

at the air interface and services with a high priority need to


be scheduled first.
For the configuration procedure, refer to 3.5 Configuring the
PIS Function.

Table of Contents
Configuring the Work Mode ........................................................................................3-2
Configuring ODU Parameters.....................................................................................3-3
Configuring the ATPC Function ..................................................................................3-5
Configuring the ACM Function....................................................................................3-6
Configuring the PIS Function......................................................................................3-9

3-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

3.1 Configuring the Work Mode


This procedure describes how to configure the operation mode, bandwidth, and modulation
mode of the equipment in accordance with the network planning.
A broader bandwidth indicates a higher modulation mode and a larger radio transmission
capacity but a lower system transceiving performance. The bandwidths for TDM services
and Ethernet services are allocated automatically in accordance with the traffic. This
feature increases the bandwidth utility.

Caution!
The configuration of work mode results in instantaneous service disconnection.

Steps
1. In the left pane, select Radio Link > Basic Configuration. The radio link configuration
page is displayed, see Figure 3-1.
Figure 3-1 Basic Radio Link Configuration Page

Note:
Current Capacity is calculated by the default bandwidth and modulation mode.

2. Click the tab of the transmit unit to be configured. In the Transmit Unit Info area,
the information of the current transmission unit, such as slot number, capacity, and
whether ACM is supported, is displayed.
3-2
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 3 Radio Link Data Configuration

3. Select the bandwidth and the modulation mode from the Bandwidth and Modulation
Mode lists respectively, see Figure 3-2.
Figure 3-2 Configuring the work Mode

Bandwidth: 7 M, 14 M, 28 M, 56 M and 40 M.
Modulation Mode: QPSK , 16QAM , 32QAM , 64QAM , 128QAM , 256QAM ,
512QAM, 1024QAM, and 2048QAM.
4. Select or clear Set also remote unit as required.
l If Synchronize bandwidth to remote NE is selected, the bandwidth setting at
the remote end is synchronized with the local end.
l If Synchronize bandwidth to remote NE is cleared and the operation mode of
the remote end is different from the local end, the communication link is broken.
5. Click Apply.
End of Steps

3.2 Configuring ODU Parameters


This procedure describes how to set the ODU frequency parameters and power
parameters. To ensure normal communication, the ODU transmit power and receive
power of the local end must match those of the remote end respectively.

Steps
1. In the left pane, select Radio Link > Basic Configuration. The radio link configuration
page is displayed. In the RF Parameter Configuration area, configure Frequency
Parameter (kHz) and Power Parameter (dBm), see Figure 3-3.

3-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 3-3 RF Parameter Configuration Area

2. In accordance with the frequencies in the microwave link planning, enter the
frequencies of the the master ODU and slave ODU in TX Frequency Configuration
text box. The transmit frequency must be within the range which is set by TX
Frequency Range.
3. When ODU Type is SRU, select the duplex spacing of the master/slave ODU from the
T/R Spacing drop-down list.
When ODU Type is Others, configure RX Frequency Configuration. The value must
be within the TX Frequency Range.
4. In the TX Power Configuration text box, enter the transmit power of the master ODU
and the slave ODU. The configured transmit power must be within the range which is
set by TX Power Range.
5. (Optional) Select Synchronize TX frequency configuration to remote NE..
l If you modify the transmit frequency or receive frequency for the local end and
clear Synchronize TX frequency configuration to remote NE., the link in use
will be disconnected after you click Apply.
l If you modify the transmit frequency or receive frequency for the local end and
select Synchronize TX frequency configuration to remote NE., both the
transmit frequency and receive frequency for the remote end are modified after
you click Apply and the link in use will not be disconnected.
6. Click Apply.
End of Steps

3-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 3 Radio Link Data Configuration

3.3 Configuring the ATPC Function


The Automatic Transmit Power Control (ATPC) function enables the system to adjust the
transmission power at the local end in accordance with the receive power at the remote
end. If the receive level at the remote end is not within the ATPC adjustment range, the
transmission power needs to be adjusted to enable the receive power at the remote end
to be within the adjustment range. If the transmission power of ODU is adjusted to the
threshold value but the receive power at the remote end is not within the ATPC adjustment
range, the transmission power does not need to be adjusted.

Context
l
l
l

During the process of exchanging microwave link's antennas, ATPC Switch should be
set to OFF, and the transmission power of ODU should be set to an appropriate value.
The ATPC function can be accomplished only when it is enabled on both ends.
After the ATPC function is disabled, the transmission power of ODU return to the value
before ATPC is enabled. That may lead to instantaneous link disconnection.

Steps
1. In the left pane, select Radio Link > Basic Configuration, and select ATPC
Parameter Configuration, see Figure 3-4.
Figure 3-4 ATPC Parameter Configuration Example

2. Configure the ATPC parameters. For a description of the parameters, refer to Table
3-1.
Table 3-1 ATPC Parameters
Parameter

Value Range

Default

Description

Value
ATPC Enable

Enable

Disable

Disable

Determines whether to enable the ATPC). With


this function, the system transmission power
can be adjusted within a certain range according
to the remote end receiving level.

3-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default

Description

Value
High

70 to 30

45

Sets the highest transmission power of the

Threshold

ATPC function. The ATPC function automatically


adjusts the transmission power at the local end
according to the receive level at the remote end.
If the receive level at the remote end is not within
the ATPC adjustment range, it is necessary
to adjust the transmission power to make the
receive level at the remote end be within the
adjustment range.
If the ODU transmission power is adjusted to
the power threshold but the receive level at the
remote end is not within the ATPC adjustment
range, the transmission power will not be
adjusted.

Low

70 to 30

65

Sets the lowest received level at the remote end.

20 to 40

Sets the lowest transmission power at the local

Threshold
Min Tx Power
(dBm)

end. It ensures that the receiving condition


at the remote end is not affected by signal
degradation due to low transmission power at
the local end during ATPC adjustment.
The priority of this parameter is higher than
ATPC low threshold.

Max Tx

20 to 40

Sets the highest transmission power at the local

Power (dBm)

end. It ensures that other links can operate


properly and are not affected by high ODU
transmission power at the local end during
ATPC adjustment.
The priority of this parameter is higher than
ATPC high threshold.

3. Click Apply.
End of Steps

3.4 Configuring the ACM Function


The ACM function enables the device to use different modulation modes in accordance with
the current channel status, which is represented by the Mean Square Error (MSE) value.
This function improves system transmission efficiency and spectrum utilization when the
channel quality is good. It also ensures link reliability of high priority services when the
channel quality is deteriorated.
3-6
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 3 Radio Link Data Configuration

Context
l
l
l

During the process of exchanging microwave link's antennas, ACM Switch should be
set to OFF.
The ACM function can be implemented only after it is enabled at both ends of the link.
The change of ACM Switch status results in instantaneous link disconnection.

Steps
1. In the left pane, select Radio Link > Basic Configuration, and select ACM
Configuration, see Figure 3-5.
Figure 3-5 ACM Configuration Example

2. Configure the ACM parameters. For a description of the parameters, refer to Table
3-2.
Table 3-2 ACM Parameters
Parameter

Value Range

Default

Description

Value
ACM Enable

Enable

Disable

Disable

Sets whether the ACM function is enabled.


The ACM function enables the coding and
modulation modes to be automatically
adjusted according to channel quality.

MSE

Automatically

Sets the MSE value in the active status

evaluated by the

and standby status.

system

MSE reflects the digital signal


performance. The RMUC/RMUD
board receives IF signals, filters and
decodes the signals, and outputs them as
digital signals. Normally, if the MSE value
is less than -32, the signal performance
is good.

3-7
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default

Description

Value
l

Running TX

Automatically

Modulation

evaluated by the

this parameter will be regulated

system

automatically according to channel

If the ACM function is enabled,

quality.
l

If the ACM function is disabled, this


parameter is applied as the transmit
modulation mode at the local end.

Running RX

Automatically

Modulation

evaluated by the

this parameter will be regulated

system

automatically according to channel

If the ACM function is enabled,

quality.
l

If the ACM function is disabled, this


parameter is applied as the receive
modulation mode at the local end.

Start Modulation

End Modulation

Record ACM Log

QPSK

16QAM

one-hop link when the ACM function is

32QAM

enabled.

64QAM

128QAM

256QAM

512QAM

1024QAM

2048QAM

QPSK

16QAM

one-hop link when the ACM function is

32QAM

enabled. The end modulation mode must

64QAM

be higher than the start modulation mode.

128QAM

If they are the same, the ACM function

256QAM

does not take effect.

512QAM

1024QAM

2048QAM

Enable

Disable

Disable

Sets the lowest modulation mode for a

Sets the highest modulation mode for a

Sets whether the Record ACM Log


function is enabled.

3. Click Apply.
End of Steps

3-8
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 4

TDM Service Data


Configuration
Step

Configuration

Description

Configure cross

Required for the TDM relay service.

connections.

For the configuration procedure, refer to 4.1 Configuring a P2P


Route.

Configure the SNCP

Required if a Sub-Network Connection Protection (SNCP) ring

route.

network needs to be configured.


For the configuration procedure, refer to 4.2 Configuring an SNCP
Protection Route.

Table of Contents
Configuring a P2P Route............................................................................................4-1
Configuring an SNCP Protection Route ......................................................................4-3
Configuring an SNCP+ Protection Route ....................................................................4-5
Configuring the CES Function ....................................................................................4-8

4.1 Configuring a P2P Route


This section describes how to configure cross connection of TDM services, that is, the
route of TDM services. The ZXMW NR8120A/8120D supports cross connections between
E1-level TDM services.

Steps
1. In the left pane, select TDM > P2P. The TDM P2P route configuration page is
displayed, see Figure 4-1.

4-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 4-1 P2P Route Configuration Page

2. Click Add, the P2P Route Configuration dialog box is displayed, see Figure 4-2.
Figure 4-2 P2P Route Configuration Dialog Box

Configuring routing parameters


3. Select priority level 16 from the Priority drop-down list.
4. Set Shelf No., TN, and Port No. at the source end.
For 1+1 protection, the TN of the RCMUC/RCMUD is 5.
5. Set Shelf No., TN, and Port No. at the destination end.
TN is the transmit unit number configured on the shelf (generally, it is the slot number
where the service board is located).
For port number, refer to Port No. at the source end.
Adding and activating cross connection configuration
6. Click Add to add TDM service route. The configured cross connection will be displayed
in the P2P route table, and it is in inactivated state.
7. Select the cross connection, and click Activate.
End of Steps

4-2
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 4 TDM Service Data Configuration

4.2 Configuring an SNCP Protection Route


This procedure describes how to configure SNCP protection route parameters, such as
cross level, cross direction, and protection mode.
SNCP protection, also called subnetwork connection protection, means that a dedicated
protection route is pre-arranged for a network. When the working channel fails or the
performance is deteriorated, the protection channel substitutes the working channel to
ensure reliable microwave link transmission.
The SNCP configuration specifies the principle of using the protection channel for TDM
services, for example, whether to use the protective route when the working route is faulty
and whether to switch back to the working route after it restores to normal operation.

Steps
1. In the left pane, select TDM > SNCP. The TDM SNCP route configuration page is
displayed, see Figure 4-3.
Figure 4-3 SNCP Route Configuration Page

2. Click Add, the dialog box is displayed, see Figure 4-4.


Figure 4-4 SNCP Route Configuration Dialog Box

4-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Configuring route parameters


3. In the Priority drop-down list, select an appropriate priority level.

Note:
The priority level is from 1 to 6. The smaller value of Priority is, the higher the
corresponding priority level is.

4. In the Protection Mode drop-down list, select Non-Revertive or Revertive.


l Non-Revertive: After the service is switched from the working channel to the
protection channel due to poor channel quality, if the working channel restores
normal, the service will not be switched back to the working channel. In this case,
Wait-to-Restore Time(s) is in grey and not editable.
l Revertive: After the service is switched from the working channel to the protection
channel due to poor channel quality, if the working channel restores normal, the
service will be switched back to the working channel after a specified WTR time.
In this case, Wait-to-Restore Time(s) is editable, and the default value is 600 ms.
5. In the Hold-Off Time (ms) text box, enter the hold-off time.
If the current channel is not restored within the specified hold-off time, the service will
be switched to the other channel. This parameter helps avoid frequent switchover.
6. Set Shelf No., TN, and Port No. at the source end (including the active and protected).
TN is the transmit unit number configured on the shelf (generally, it is the slot number
where the service board is located).
7. Set Shelf No., TN, and Port No. at the destination end.
TN is the transmit unit number configured on the shelf (generally, it is the slot number
where the service board is located).
For port number, refer to Port No. at the source end.
Adding and activating SNCP protection
8. Click Apply, and the SNCP configuration is added to the SNCP route table.
9. Select the SNCP route and click Activate.
Configuring SNCP switchover
10. Select an SNCP route in the SNCP route list, and click Switch. The SNCP Switch
dialog box is displayed, see Figure 4-5.

4-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 4 TDM Service Data Configuration

Figure 4-5 SNCP Switch Dialog Box

11. Select a switch command.


l Auto: The service is automatically switched to the available channel according to
the protection mode and the channel condition.
l Protection Lockout: The protection channel is closed and no protection is
provided.
l Force to Slave: The system forcibly switches the service to the protection channel
irrespective of whether the channel is normal or not.
l Force to Master: The system forcibly switches the service to the working channel
irrespective of whether the channel is normal or not.
l Manual to Slave: Users need to manually switch the service to the protection
channel when the protection channel is normal. If the protection channel is
improper, the system automatically switches the service back to the working
channel.
l Manual to Master: Users need to manually switch the service to the working
channel when the working channel is normal. If the protection channel is improper,
the system automatically switches the service back to the protection channel.
l Clear: The system clears the previous switchover operations, that is, clear the
Hold On timer. After that, the SNCP clear command becomes an automatic
command.
12. Click Apply.
End of Steps

4-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5

Ethernet Service Data


Configuration
Table of Contents
Configuring Ethernet Ports
Configuring a VLAN
Configuring QoS
Configuring the LACP Function

5-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

5.1 Configuring Ethernet Ports


Ethernet port is used to provide service access and signal transmission for microwave
transmission.

Steps
Configuring Physical Ethernet Interfaces
1. In the left pane, select Home > Home. The board page is displayed, see Figure 5-1.
Figure 5-1 Board Page

The Ethernet electrical and optical interfaces are mutually exclusive.


2. Double-click the desired interface, and click Apply to enable it.
The interfaces marked with red crosses are disabled interfaces.
The interfaces without red crosses are enabled interfaces.
Configuring Logical Ethernet Ports
3. Basic configurations of the Ethernet interface
a. In the left pane, select ETH > Port Related > Basic Configuration. The basic port
configuration page is displayed. Select the line where the port to be configured is
located, and click Modify. The Port Configuration dialog box is displayed, see
Figure 5-2.

5-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

Figure 5-2 Ethernet Port Basic Configuration Page

b. Configure the related parameters.


c.

Click Apply.

d. Use the same method to configure other ports.

End of Steps

5-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

5.2 Configuring a VLAN


5.2.1 Configuring VLAN Port Information
This procedure describes how to configure port VLAN types, such as Access, Trunk,
Hybrid, Customer, Provider, and UserDefine.
Port Type

Description

Access

An Access port is used to connect the VLAN switch with a device that cannot
identify VLAN tags, for example, work station. This port type transmits only
frames without VLAN tags and can be associated with only one VLAN.

Trunk

A Trunk port is used to transmit services of multiple VLANs. This port type
transmits only frames with VLAN tags and can bear multiple VLANs.

Hybrid

A Hybrid port can transmit frames with or without tags. However, for a specific
VLAN, the frames transmitted by this port type must be all with tags or all
without tags.

Customer

A Customer port is used to identify an inner VLAN tag or untagged packet, and
add a specified outer VLAN tag. The frames whose TPID of the inner VLAN
tag is consistent with the setting will be discarded.
5-11

SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Port Type

Description

Provider

A Provided port is used to identify the outer VLAN tags that are consistent with
the configured TPID and transmit them. At the same time, the inconsistent
frames are discarded.

UserDefine

A UserDefine port is used for VLAN Tag in VLAN Tag (QinQ). It can be
configured flexibly based on the actual requirement.
QinQ allows adding a VLAN tag to the original 802.1Q tag packet. The original
tag becomes the inner tag and the VLAN is marked as CVLAN. The added tag
becomes the outer tag and the VLAN is marked as SVLAN.

Steps
1. In the left pane, select ETH > VLAN > Port Info Configuration. The VLAN port
information page is displayed, see Figure 5-12.
Figure 5-12 Port Information Configuration Page

2. Select the port to be configured and click Modify. The Port Configuration dialog box
is displayed, see Figure 5-13.

5-12
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

Figure 5-13 Port Configuration Dialog Box

3. Set Port Type, Port Default Priority, PVID, and VLAN ID.
l The PVID must be within the VLAN ID.
l The VLAN IDs to be added or deleted can be continuous or discrete. To add
continuous VLAN IDs, use the symbol -, for example, 1-10.
4. Click Apply.
End of Steps

5-13
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

5.3 Configuring QoS


Configuration Item

Description

Ingress

Traffic classification is to classify packets into different priorities

Traffic classification

or services.
For the configuration procedures, refer to 5.4.1 Configuring Queue
Priorities and 5.4.3 Configuring the Access Control Policy (ACL).
Traffic policing

Traffic policing is to limit the traffic entering a network to the


allowed range. If the packet traffic of some connection is too large,
traffic policing will discard the packet or reset its priority to protect
network resources and the operator's investment.
For the configuration procedure, refer to 5.4.2 Configuring Access
Rate Control (CAR).

5-17
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Configuration Item

Description

Egress

Congestion

The congestion avoidance technology is normally used at the

avoidance and

network bottleneck to monitor network traffic load and avoid

management

potential congestions. The commonly used congestion avoidance


mechanisms are tail drop, Random Early Detection (RED), and
Weighted Random Early Detection (WRED).
Congestion will occur on the interface where the arrival rate of
packets is faster than the sending rate. The queue scheduling
technology is always used to solve network congestion.
For the configuration procedures, refer to 5.4.4 Configuring
Queue Management and 5.4.6 Configuring Packet Aging Time.

Traffic shaping

Traffic shaping is to limit the traffic of a packet type from a port so


that packets can be sent at an even speed;
Buffer and token bucket are normally used to implement traffic
shaping. The token bucket controls the rate for sending packets.
The packets exceeding the rate limit are cached in the buffer and
waits to be sent as scheduled.
For the configuration procedure, refer to 5.4.7 Configuring the
Flow Rate Limit Policy.

5.3.1 Configuring Queue Priorities


This procedure describes how to configure queue priorities for ports.

Steps
1. In the left panel, select ETH > QoS > Priority Mapping.
configuration page is displayed, see Figure 5-17.

The queue priority

Figure 5-17 Port Priority Configuration Page

5-18
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

2. Select the line where the port to be configured is located, and click Modify. The
Priority Mapping dialog box is displayed, see Figure 5-18, Figure 5-19.
Figure 5-18 Port Queue Priority Configuration Dialog Box (802.1p Page)

Figure 5-19 Port Queue Priority Configuration Dialog Box (DSCP Page)

3. Configure the port queue priority mapping parameters.


4. Click Apply.
End of Steps

5-19
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

5.3.2 Configuring Queue Management


This section describes how to set the queue management policy and the congestion
management (CM) policy.
Three CM policies are supported:
l
l

Tail Drop: It is the default congestion management policy. Due to limited capacity of
the tail drop chip, the packets exceeding the capacity are discarded directly.
Random Early Detection: This policy supports flexible configurations. You can set
the threshold and probability of dropping packets for each queue color. Among the
three colors (yellow, red, and green), yellow queues have the same threshold and
probability as red queues.
Weighted Random Early Detection: The queue length percentage and packet drop
rate of the packets marked in yellow or green should be configured respectively for a
port.

Steps
1. In the left pane, select ETH > QoS > Queue Management. The queue management
policy configuration page is displayed, see Figure 5-25.
Figure 5-25 Queue Management Policy Configuration Page

2. Select the port to be configured and click Detach.


3. On the QoS Mode CFG page, configure the Mode Type, see Figure 5-26.

5-29
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 5-26 Configure the Mode Type

4. Switch to the Congest CFG page, see Figure 5-27.


Figure 5-27 Congest CFG Page

5. Configure the congestion management parameters.


parameters, refer to Table 5-8.

For a description of the

5-30
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

Table 5-8 Congestion Management Parameters


Parameter

Value Range

Default

Description

Value
Congestion

Tail Drop

Management

RED

congestion mode.

Policy Select

WRED

Tail Drop

Random Early Detection

Weighted Random Early Detection

Red/Yel-

Tail Drop

0100

low/Green

Sets the policy for dropping packets in

Sets the threshold of red/yellow/green


packet length to drop packets.

Packet Drop
Threshold
Red/Yel-

0100%

100.0%

low/Green

Sets the maximum drop percentage of


red/yellow/green packets.

Packet Maximal
Drop Percent

6. Switch to the QoS Para CFG page, see Figure 5-28.


Figure 5-28 QoS Para CFG Page

a. Click Modify after the port name, configure the port parameter, see Figure 5-29.

5-31
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 5-29 Configure Port Parameter

b. Click Modify after the queue name, configure the quene parameter, see Figure
5-30.
Figure 5-30 Configure Quene Parameter

End of Steps

5.4 Configuring the LACP Function


Link Aggregation Control Protocol (LACP) is based on the IEEE802.3ad standard. It is
used to implement dynamic link aggregation. It allows binding multiple physical interfaces
into a logical interface. The physical interfaces form a redundant and backup relationship
and implement load sharing.
The LACP function enables multiple physical links to be bound into a logical link and form
a link aggregation group. It accomplishes the following functions:
l

Increasing bandwidth: The width of the bound physical links is the sum of the
bandwidths of all physical links in the link aggregation group.

5-32
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

l
l

Improving system stability and availability: The aggregation link is available even if
one physical link is disconnected.
Sharing load: The aggregation link sends data in accordance with a policy to achieve
load balancing.

Prerequisite
l
l

The required boards and ports are added.


The corresponding ports are enabled in the Ethernet port configuration.

Steps
1. In the left pane, select ETH > Port Related > Port Configuration. The port
configuration page is displayed. Ensure that the ports for configuring aggregation are
all enabled. If not, enable the disabled ports.
2. Configure the LACP port:
a. In the left pane, select ETH > LACP > Port Configuration. The LACP port
configuration page is displayed. Click Add. The Port Configuration dialog box
displayed, see Figure 5-39.
Figure 5-39 Port Configuration Dialog Box

b. From the Port drop-down list, select the port to be aggregated. Configure the
LACP port parameters.
For a description of the parameters, refer to Table 5-13.
Table 5-13 LACP Interface Configuration Parameters
Parameter

Value Range

Default

Description

Value
Port

Port names in

Specifies the port and its slot for

the drop-down

configuring the LACP protocol.

list

The ports that can be configured as


LACP ports are Ethernet physical
port and Ethernet air interface. An
5-41

SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default

Description

Value
aggregated port cannot be configured
as an LACP port.
Port Priority

165535

32768

Sets the priority for selecting member


ports in dynamic aggregation. A higher
priority level indicates that the port is
more easily to be aggregated.

Port Work

Active Mode

Mode

Passive

sends LACP packets.

Mode

Active Mode

Indicates whether the port actively

ON

Active Mode: indicates that the


port actively sends packets.

Passive Mode: indicates that the


port does not actively send packets.

Enable: indicates that the port does


not send packets.

Port

Aggregation
Mode

Aggregation

Individual

Indicates whether the specified port is

Port

Port

an individual port or an aggregation port

Individual

that can be aggregated with other ports.

Port

The default setting, Aggregation Port, is


recommended, though the two options
will have distinct differences only in a
later version.

c.

Port Ethernet

Open

Traffic

Close

Open

Indicates whether the Ethernet traffic is


enabled.

Click Apply.

d. Use the same method to add other ports to be aggregated.


3. Configure the LACP aggregation group:
a. In the left pane, select ETH > LACP > LAG Configuration.
aggregation group configuration page is displayed.

The LACP

b. Click Add. The LAG Configuration dialog box displayed, see Figure 5-40.

5-42
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

Figure 5-40 LAG Configuration Dialog Box

c.

Configure the LACP aggregation parameters. For a description of the parameters,


refer to Table 5-14.
Table 5-14 LACP Aggregation Group Parameters
Parameter

Value Range

Default

Description

Value
Aggregation

131

Index

Uniquely identifies of an aggregation


group. Multiple aggregation groups are
allowed for a device. Each aggregation ID
is assigned with an ID.

Aggregation

A character

Name

string with

SG

Names an aggregation group.

Specifies the priority of the two ends of a

at most 31
characters
Aggregation

165535

Priority

device. A lower value indicates a higher


priority.

Aggregation

Static

Policy

Manual

Static

Specifies the aggregation policy, which


can be static or manual.
For static aggregation, an aggregation
group is created on the basis of protocol
calculation.
For manual aggregation, an aggregation
group is created according to the
configuration. Manual aggregation does
not transmit or receive protocol packets.

5-43
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Parameter

Value Range

Default

Description

Value
Load

Strategy
l
l

Source

Source

Specifies the load sharing policy used by

MAC

MAC

an aggregation group. The load policy

Destination

supports load sharing based on source

MAC

MAC, destination MAC, source and

Source and

destination MAC, source IP, destination

Destination

IP, source and destination IP.

MAC
l

Source IP

Destination
IP

Source and
Destination
IP

Master Port

LACP port

Specifies the master port of an

names in the

aggregation group. After an aggregation

drop-down list

group is created, the group attributes must


be consistent with those of the master
port. That is, the attributes of the master
port are duplicated to the aggregation
group port. If the aggregation group needs
to be dismantled, resume the aggregation
group attributed to the master port and
prohibit other member ports.

LAG Port

Displayed

Specifies the member ports in an

member port

aggregation group. Two to eight members

names

are allowed.
A LACP Port belongs to only one
aggregation group.

d. Click Apply.
4. Log in to the LMT at the opposite end. Perform steps 1 through 3.
5. Connect the interfaces of the two devices for configuring aggregation by network
cables, fibers or radio link. Verify that the status indicators of the interfaces are green.
6. Open the LMT interfaces at both ends. Select ETH > LACP > LAG Info and query the
LAG information, see Figure 5-41.
If the Port Number is equal to the Active Port Number, the LAG is operating normally.

5-44
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 5 Ethernet Service Data Configuration

Figure 5-41 LAG Information

End of Steps

5-45
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 6

Other Configuration
Operation
Table of Contents
Configuring EOW
Configuring EDI
Configuring CLK/MON
Configuring User Security.

6.1 Configuring EOW


The ZXMW NR8120A/8120D supports the Engineering Order-Wire (EOW) function to
assist engineering order calling between sites. It is applicable for point-to-point calling
and cross-site calling.
The EOW function has the following advantages:
l Reduces calling cost
l Facilitates voice communications between engineers in areas without radio signal
coverage during early phase of a project.

Steps
1. In the left pane, select Maintenance > Auxiliary Service > EOW. The EOW
configuration page is displayed, see Figure 7-2.

SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Figure 7-2 EOW Page

2. Configure the parameters of all related sites. For a description of the parameters, refer
to Table 7-2.
Table 7-2 EOW Parameters
Parameter

Value Range

Description

Global

Open

An EOW call can be made only when both sites at

Enable

Close

the two ends and the relay sites are globally enabled.

Site Type

Call Site

For a point-to-point call, the Site Type at both ends

Relay Site

are configured as Call Site.


For a cross-site call, the Site Type at both ends
are configured as Call Site and the relay sites are
configured as Relay Site. Multiple relay sites are
allowed.

Call

TN=5

Specifies the EOW calling direction, which

Direction

TN=6

determines the air interface for transmitting EOW


data.
l

When only one air interface is available, the air


interface of RCMUA is TN=5.

When 1+1 protection is enabled, the air


interfaces of RCMUA and RMEA boards are
TN=5.

When the air interfaces of RCUMA and RMEA


boards are in different direction, the air interface
of RCMUA is TN=5 and that of RMEA is TN=6.

When only one interface is available or 1+1 protection


is enabled, only TN=5 is displayed on the GUI.

3. Insert the headset into the EOW interface of the RCMUC/RCMUD board, and then
press Call. After hearing the buzzer sound, the opposite party insert a headset and
start the conversation.
The devices at the ends of a point-to-point calling can communicate with each other.

7-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

The devices at the ends of a cross-site calling can communicate with each other.
The relay devices only serve for back-to-back transmission of voice data on the air
interface.
End of Steps

6.2 Configuring EDI


The ZXMW NR8120A/8120D supports the External Device Interface (EDI) alarm input and
output function. It supports at most four ways of EDI alarm input and two ways of EDI alarm
output.
After EDI input alarm parameters are configured, the ZXMW NR8120A/8120D can report
input alarm information after receiving external EDI output alarms.
After EDI output alarm parameters (alarm type) are configured, the ZXMW
NR8120A/8120D can detect internal alarms and outputs corresponding EDI alarms on
the external devices.

Prerequisite
For EDI input alarm configuration, all ports are connected to the alarm generation devices.
For EDI output alarm configuration, all output ports are connected to the alarm detection
devices.

Steps
l

Configuring EDI Input Alarms


1. In the left pane, select Home > Home. The board interface diagram is displayed,
see Figure 7-3.
Figure 7-3 Board Interface Diagram (EDI in Disabled)

2. Double-click the EDI in interface to enable it, see Figure 7-4.

7-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Figure 7-4 Board Interface Diagram (EDI in Enabled)

3. In the left pane, select Maintenance > Auxiliary Service > EDI > Input. The EDI
input page is displayed, see Figure 7-5.
Figure 7-5 EDI Input Page

4. Select a record, and click Modify. The EDI IN dialog box is displayed, see Figure
7-6.
Figure 7-6 EDI Input Parameter Configuration Example

5. Configure the EDI input parameters, and click Apply.


l

Configuring EDI Output Alarms


1. In the left pane, select Home > Home, and double-click the EDI out / SC interface
to enable it.
2. In the left pane, select Maintenance > Auxiliary Service > EDI > Output. The
EDI output configuration page is displayed, see Figure 7-7.

7-5
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 7-7 EDI Alarm Output Page

3. Select an output record, and click Modify. The EDI OUT dialog box is displayed,
see Figure 7-8.
Figure 7-8 EDI Alarm Output Configuration Page

4. Configure the EDI output parameters, and click Apply.


End of Steps

6.3 Configuring CLK/MON


This procedure describes how to configure the CLK/MON interface to provide the clock
service function or service monitoring function.

Prerequisite
For the port monitoring function, the monitoring interface is correctly connected to the
cabinet to be monitored.

Steps
1. In the left pane, select Home > Home.
2. Double-click CLK / MON port to enable it.
3. In the left pane, select Maintenance > Auxiliary Service > CLK/MON. The CLK/MON
page is displayed, see Figure 7-9.

7-6
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Figure 7-9 CLK/MON Page

4. Select a record, and click Modify. The configuration information is expanded, see
Figure 7-10.
Figure 7-10 CLK/MON Configuration Example

5. Set Port Function to Clock or Monitor, and then click Apply.


End of Steps

6.4 Configuring User Security


This procedure describes how to configure user security, including the user lockout and
user disable/enable functions.
l

User lockout: When a user enters wrong passwords sequentially, the system disables
this user account until it is automatically enabled after some time or manually enabled
by the administrator.
User disable/enable: When a user is not required, all operations of this user can be
prohibited by disabling the user account. To restore the permission for a disabled
user, you can enable this user.

Prerequisite
You have already logged in to the LMT as the administrator.

Steps
Configuring the Lockout Information
1. In the left pane, select Security Management > User. The User Security page is
displayed, see Figure 7-11.
7-7
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

Figure 7-11 User Security Page

2. In the User Security Management area, configure the Lockout Threshold and the
Lockout Time. For a description of the lockout parameters, refer to the following table.
Parame-

Value Range

ter
Lockout

Default

Description

Value
110 Integer

Number of times that a user is allowed to enter wrong

Thresh-

passwords. The user will be locked if this threshold

old

is exceeded.

Lockout

10, 20, 30, 40,

Time

50, 60

10

Time (minute) for locking a user. The user will be


automatically unlocked when the time is exceeded.

3. Click Apply.
Configuring User Disable/Enable
4. In the User Management area, select the user name to be modified. Click Modify.
The User Info Configuration dialog box is displayed, see Figure 7-12.
Figure 7-12 User Info Configuration Dialog Box

5. Set Enable or Disable as Status. Click Apply.


l Disable: Operations of this user are prohibited.
l Enable: The user permission is restored.
End of Steps
7-8
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

This page intentionally left blank.

7-10
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 7

Configuration Check
Table of Contents
Checking NEs
Checking Alarms

7.1 Checking NEs


This procedure describes how to verify NE configuration based on the network planning.

Steps
1. In the left pane, select Setup > System > Parameter. The NE information page is
displayed, see Figure 8-1.
Figure 8-1 NE Information Page

2. Ensure that the NE information is correct.


End of Steps

7.2 Checking Alarms


By checking the alarms, users can locate the exceptions during system operation and
handle the faults in a timely manner.
8-1
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

For the alarm severity levels, refer to Table 8-1.


Table 8-1 Alarm Severity Levels
Icon

Color

Alarm Severity

Red

Critical

Orange

Major

Yellow

Minor

Light green

Warning

7.2.1 Checking Active Alarms


This procedure describes how to check active alarms so that users can discover and solve
device faults in a timely manner to ensure normal operation. Active alarms are the alarms
that are currently on the device. Filtered alarms are not contained in the active alarm list.
You can check the filtered alarms by using the filtering rule.

Steps
1. Log in to the Web LMT.
2. In the left pane, select Alarm > Current.
3. In the Current Alarm area in the right pane, select the slot No. and alarm level, and
then click Query. The query result is displayed in the lower part, see Figure 8-2.
Figure 8-2 Active Alarms

4. Select an alarm, and click Detail to view the alarm details, see .

8-2
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Chapter 8 Configuration Check

Figure 8.1

End of Steps

7.2.2 Checking History Alarms


This procedure describes how to check history alarms for analyzing and resolving potential
problems.
History alarms are the alarms that are not displayed on the device. The LMT can store a
maximum of 2000 history alarms.

Steps
1. In the left pane, select Alarm > History.
2. Check the history alarms in the right pane, see Figure 8-3.
Figure 8-3 History Alarms

3. Select an alarm, and click Detail to view the alarm details.


End of Steps

8-3
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

This page intentionally left blank.

8-4
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Glossary
ACL
- Access Control List
ACM
- Adaptive Coding and Modulation
AES
- Advanced Encryption Standard
AIS
- Alarm Indication Signal
AOU
- All Outdoor Unit
ATPC
- Automatic Transmit Power Control
CAR
- Committed Access Rate
CBS
- Committed Burst Size
CC
- Connection Confirmation
CFM
- Connectivity Fault Management
CIR
- Committed Information Rate
DR
- Designated Router
EDI
- External Device Interface
EFM
- Ethernet in the First Mile
EOW
- Engineering Order-Wire
ERPS
- Ethernet Ring Protection Switching
IDU
- Indoor Unit
I
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

ZXMW NR8120A/8120D Configuration Guide

IP
- Internet Protocol
LACP
- Link Aggregation Control Protocol
LLDP
- Link Layer Discovery Protocol
LMEP
- Local Maintenance association End Point
LMT
- Local Maintenance Terminal
MA
- Maintenance Association
MAC
- Message Authentication Code
MIB
- Management Information Base
MIP
- Maintenance domain Intermediate Point
MP
- Maintenance Point
MSE
- Mean Square Error
MSTP
- Multiple Spanning Tree Protocol
NBMA
- Non-Broadcast Multiple Access
NMS
- Network Management System
ODU
- Outdoor Unit
OSPF
- Open Shortest Path First
OUI
- Organizationally Unique Identifier
PBS
- Peak Burst Size
PIR
- Peak Information Rate
II
SJ-20150804150350-005|2015-10-23 (R1.1)

ZTE Proprietary and Confidential

Glossary

PTP
- Precision Time Protocol
QoS
- Quality of Service
RED
- Random Early Detection
RMEP
- Remote Maintenance association End Point
RSTP
- Rapid Spanning Tree Protocol
SNCP
- Sub-Network Connection Protection
SNMP
- Simple Network Management Protocol
SSM
- Synchronization Status Message
STP
- Spanning Tree Protocol
SVLAN
- Service Virtual Local Area Network
TCP
- Transmission Control Protocol
TDM
- Time Division Multiplexing
VLAN
- Virtual Local Area Network
WRED
- Weighted Random Early Detection

III